0% found this document useful (0 votes)
187 views2 pages

NWP Rockwool Filled Wall Panel-Tds

This document provides technical specifications for NWP ROCKWOOL filled facade panels. The panels have high load-bearing performance due to their compressive strength and provide high thermal insulation due to their closed cell structure. They are resistant to water and moisture absorption. Fire classification is A2-S1-D0 and panels meet CE and EN standards. Technical details are provided about coating and filling thicknesses, materials, load bearing capacity and company certifications.

Uploaded by

Rawaa Al-Edreesi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
187 views2 pages

NWP Rockwool Filled Wall Panel-Tds

This document provides technical specifications for NWP ROCKWOOL filled facade panels. The panels have high load-bearing performance due to their compressive strength and provide high thermal insulation due to their closed cell structure. They are resistant to water and moisture absorption. Fire classification is A2-S1-D0 and panels meet CE and EN standards. Technical details are provided about coating and filling thicknesses, materials, load bearing capacity and company certifications.

Uploaded by

Rawaa Al-Edreesi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

TECHNICAL DATA SHEET

NWP ROCKWOOL FILLED FACADE PANEL

Description of Product

MAIN FEATURES
Nuhpanel ROCKWOOL insulation wall panels have high load-carrying performance due to
・ Light high compressive strength. It allows you to choose the most economical form suitable for
・ Hight heat insulation your building. Nuhpanel ROCKWOOL insulated wall panels provide high thermal insulation
・ Long lasting
due to its closed cell structure. It does not absorb water and moisture and does not absorb
・ Resistant
water due to its resistance against vapor.

CERTIFICATES

A2-S1-D0
TS EN 14509
CE

Rib Type Form Actual Width Minumum Lenght Maximum Lenght


Fire Class : A
Micro ribs 01/1000 1000 mm 2.500 mm 14.500 mm

▸ Technical Drawing

▸ Joint Detail

Hidden screw joint details used in Nuhpanel facade


panels are resistant to water leaks and separation.
Thanks to its hidden screw structure, it provides
integrity in structures and protects itself against
external influences and ensures long life.

This technical data sheet is prepared according to the latest technical information and standards of Nuhpanel Yapi Elemanlari Sanayi Ticaret A.Ş. / Gebze, KOCAELİ. Technical changes due to
further developments are possible.

Page 1/2
OPTIONS Technic Details

COATING THICKNESS ▸ Coating Material


Standard EN 10143 EN 10327 EN 10327
・ 0,45 mm x 0,35 mm
・ 0,50 mm x 0,40 mm Material Type Thickness (mm) Type Galvanize (gr/m2)
・ 0,60 mm x 0,50 mm
・ 0,60 mm x 0,60 mm Top Steel Sheet 0,60 DX 51 100 - 110
・ 0,70 mm x 0,50 mm
・ 0,80 mm x 0,60 mm Bottom Steel Sheet 0,55 DX 51 100 - 110

FILLING THICKNESS ▸ Filling Material `


Standard TS EN 14509 TS EN 12667 TS EN 13501-1
・ 40 mm
・ 50 mm ROCKWOOL Density Thickness (mm) Thermal Conductivity Reaction to Fire
・ 60 mm (System)
・ 70 mm 100 kg/m³ ±2 100 mm 0,040 A
・ 80 mm
・ 100 mm
・ 120 mm Ear Parts 130 kg/m³ ±2
・ 150 mm

SURFACE COATING ▸ Surface Coating


Standard #BAŞV! #BAŞV! #BAŞV!
・ PVDF
・ PLASTISOL
・ PVC POLYESTHER Rear Surface Front Surface Primer Front Surface Top Front Surface Total
・ PVC-EVA
7 micron 5 micron 20 micron 25 micron

FOR INFORMATION ▸ Load Bearing Chart*


Standard
www.nuhpanel.com.tr (L/200)
Purlin Spacing (cm) kg/m² Purlin Spacing (cm) kn/m²
444 4 684 100 252 100 2,47
150 292 150 2,86
200 148 200 1,45
250 119 250 1,17
COMPANY CERTIFICATES 300 95 300 0,93
350 81 350 0,79
・ IS0 9001 400 62 400 0,61
・ IS0 14001 450 N/A 450 N/A
・ ISO 18001 500 N/A 500 N/A
・ TSE
・ YMB * Our products are tested in accordance with the standards in Istanbul Technical University.

This technical data sheet is prepared according to the latest technical information and standards of Nuhpanel Yapi Elemanlari Sanayi Ticaret A.Ş. / Gebze, KOCAELİ. Technical changes due to
further developments are possible.
Page 2/2