USB2.
0 to RS232
serial cable
This product is an enhanced universal asynchronous transceiver transmission
standard USB2.2 to RS232 serial port product. The USB interface fully complies with
the full-speed USB2.0 specification and supports full-speed data transmission rate.
The serial port complies with the RS232 standard interface. The wire is provided with
aluminum foil and 64B tinned. The copper braid is double shielded, which has strong
anti-interference and more stable signal. It can be used for RS232 serial devices such
as cash registers, LED displays, CNC machine tools, industrial machines, industrial
instruments, barcode printers, etc.
(1) support baud rate of 300~115200bps (can support 1000000bps).
(2) Support for large data receiving and sending buffer function: 256byte sending, 768
byte receiving.
(3) Support data bits: 7, 8, 9, stop bits: 1, 1.5, 2, check bits: Even, None, Odd, Mark,
Space.
(4) Automatic hardware (RST/CTS or DTR/DSR) flow control
(5) Support handshake protocol control, MODEM contact signal : DCD, RXD, RXD,
DTR, GND, DSR, RTS, CTS, RI.
(6) Anti-electromagnetic interference design, USB bus self-powered, plug and play
(7) Circuit integrated ESD protection: ±15KV IEC1000-4-2 air gap discharge.
±8KV IEC1000-4-2 contact discharge.
(8) Support WindowsXP, Win7, Win8, Win10, Mac system.
Ⅲ.Pin Definition;Link Diagram
Serial Communication Transmission Function
DB9 type
port pins code direction description
1 DCD I Carrier Detect
2 RXD I Data reception
3 TXD O Data sending
4 DTR O Data Terminal Ready
DB9male
5 GND Ground (GND)
232 male
6 DSR I Data Device Ready
7 RTS O Request to send
8 CTS I Clear to Send
9 RI I Ringing indication
Serial Communication Transmission Function
DB9 type
port pins code direction description
1 DCD I Carrier Detect
2 TXD O Data sending
3 RXD I Data reception
4 DSR I Data Device Ready
DB9male
5 GND Ground (GND)
6 DTR O Data Terminal Ready
232 female 7 CTS I Clear to Send
8 RTS O Request to send
9 RI I Ringing indication
Scope of application
Suitable for connecting computers
and various serial devices
Access control
Cashier PLC ISBN printer
system
CNC machine
Scanner PLAM External modem
tools
Tax control Temperature LED Display
Writing board
machine control equipment screen
Programming Industrial Industrial control
Touch screen
machine instrument machine
PL2303 G series Driver
Installation
instruction
Ⅰ. Introduction to the installation of drive steps
(1)Scan the scan code card attached to the product to
download and install the driver through the official website
Step 1:Download the driver installation package, click the PL2303G
_Windows_v200.zip compressed package, and unzip it.
Step 2: After decompression, as shown in the figure below, double-
click the application window.
Step 3: Double-click to run the program, the installation dialog box
will pop up, click "Next"
Step 4: After clicking "Next", the system will automatically complete
the installation process. After the installation process is over, click "
Finish" in the dialog box to end the installation process
(2) Set the port number in the device manager
Step 1: Right-click "Computer" and select "Manage".
Step 2: Insert the serial cable into the USB port of the computer,
select "Device Manager" in the "Management", and in the "Device
Manager", the "Port" item can check that the serial cable has been
installed with the driver. And pop up the "COM" port.
If the driver cannot be seen in the "Device Manager" after plugging
in the serial cable, but "unknown Device" is displayed, replace the
computer with another USB port for testing. If this happens, it may
be that the serial cable is faulty. It is recommended to return to the
factory for replacement.
Step 3: Seeing that the device manager recognizes the COM
slogan, it may not be able to connect with the communication
device. The picture below is the application software of a certain
LED display. You can set the port in the software to change the
COM slogan. The COM port is the same.
<IV>
Step 4: If there are no more COM ports to choose from in the
software, or the selected COM port still cannot be connected, then
you need to change the COM slogan in the device manager, right-
click the "COM" port in the figure, and select properties.
After clicking "Properties", the first pop-up is the general column.
The device status shows "This device is working normally"
indicating that there is no problem with the driver installation, and
then click "Port Settings".
<V>
After clicking "Port Settings", "Bits/Second" is the parameter
setting of the baud rate. If you need to change it, you can change
the baud rate of this serial line, and then click "OK".
If the user needs to change the serial port port, you need to click
"Advanced Settings" in "Port Settings".
In the "Advanced Settings", you can see the "COM Port Number
" setting, click the "COM Port Number" option to change the port
number of the serial cable.
<VI>
After setting the port number of the serial cable, you can return to
the "Device Manager" to check whether the serial cable has
changed the port number. If the port number still cannot be
changed, you can click Update Driver in the upper right corner of
the "Device Manager" Icon to update (generally win7 system will
automatically update the port number after setting up, XP system
needs to update the driver to see whether the port number has
changed).
<VII>
So far, the whole process of installing and using the serial cable
has been introduced. If the serial cable installation fails, or there is
an "exclamation mark" in front of the COM port, it can be tested on
other computers. If the same phenomenon occurs, it is
recommended to return to the factory for repair. If there is a
communication problem during use, please check whether your
plug is in good contact, whether the port number is wrong, whether
the baud rate has been changed, etc.; you can also turn off the
power and restart the device, or let the device recognize the serial
line, etc. Other ways to troubleshoot, but also do not eliminate
compatibility issues.
<VII >
Product Warranty Card
Customer Information
Model:
Date of purchasel:
User telephone
User address
Distributor
Agency address
User telephone: Dealer stamp valid
Intenance Records
Repair times Date Fault Treatment measures Repair work NO.