0% found this document useful (0 votes)
42 views

Z Axis After Compensation

A metrology test was performed on the Z axis of a machine called VTL-1 ROTOR MACHINING. The test analyzed the maximum and mean reversal and scatter values for the Z axis over 3 runs, finding a maximum reversal of 84.4 μm. Environmental conditions like air temperature, pressure, and material temperature were also recorded during the test.

Uploaded by

Suresh
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
42 views

Z Axis After Compensation

A metrology test was performed on the Z axis of a machine called VTL-1 ROTOR MACHINING. The test analyzed the maximum and mean reversal and scatter values for the Z axis over 3 runs, finding a maximum reversal of 84.4 μm. Environmental conditions like air temperature, pressure, and material temperature were also recorded during the test.

Uploaded by

Suresh
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

VDI 3441 - 1977:ZTZ

Z AXIS AFTER COMPENSATION


Operator: AARK METROLOGY

Machine name VTL-1 ROTOR MACHINING Serial number LSML/FA. PV -F009 Targets 18 Linear
Axis under test Z Number of runs 3 Alternate bidir Test date Tuesday 2022/10/11 01:18 PM

ZTZ - Analysis features Environmental conditions


Name Value (µm) Name Start End Min Max
Maximum reversal (U max) 84.4 Air temp [°C] 32.8 32.9 32.8 32.9
Maximum scatter (Ps max) 9.4 Air pressure [mbar] 1006.60 1006.40 1006.40 1006.60
Mean reversal (U Mean) 46.9 Air humidity [%RH] 64 64 64 64
Mean scatter (Ps mean) 6.4 Material temp 1 [°C] Not recorded Not recorded
Positional uncertainty (P) 135.5 Material temp 2 [°C] 31.3 31.3 31.3 31.3
Positional deviation (Pa) 63.7 Material temp 3 [°C] Not recorded Not recorded
Expansion coefficient [ppm/°C] 11.70 11.70

Renishaw plc CARTO - Explore 4.5 Date printed:Thursday 2022/10/13 11:43 AM