Products Solutions Services
Promass 84F
Benefits:
• Highest process safety – immune to fluctuating and harsh
environments
• Fewer process measuring points – multivariable measurement (flow,
density, temperature)
• Space-saving installation – no in/outlet run needs
• Quality – designed for custody transfer; featuring worldwide
recognized metrological approvals
• Flexible data transfer options – numerous communication types
• Automatic recovery of data for servicing
Specs at a glance
• Max. measurement error Mass flow (liquid): ±0.1 % (standard),
More information and current pricing: 0.05 % (option) Volume flow (liquid): ±0.1 % Mass flow (gas):
www.endress.com/84F ±0.35 % Density (liquid): ±0.0005 g/cm³
• Measuring range 0 to 2 200 000 kg/h (0 to 80 840 lb/min)
• Medium temperature range Standard: –50 to +200 °C (–58 to
+392 °F) High temperature: –50 to +350 °C (–58 to +662 °F)
• Max. process pressure PN 100, Class 600, 63K
• Wetted materials Measuring tube: 1.4539 (904L); 1.4404
(316/316L); Alloy C22, 2.4602 (UNS N06022) Connection:
1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Field of application: Promass F has a long standing reputation as a
highly accurate device under varying process conditions. It is suited for
broadest range of applications. Combined with the Promass 84
transmitter, Promass 84F offers premium accuracy in measurement of
liquids and gases. It will be the preferred solution for customers needing
custody transfer measurement.
Features and specifications
Promass 84F
Gas Measuring principle
Coriolis
Product headline
The flowmeter with premium accuracy, robustness and custody transfer
functionality. Highest measurement performance for liquids and gases
under varying, demanding process conditions.
Sensor features
Highest process safety – immune to fluctuating and harsh environments.
Fewer process measuring points –multivariable measurement (flow,
density, temperature). Space‐saving installation – no in/outlet run
needs. Mass flow: measurement error ±0,05 % (PremiumCal). pressure-
rated sensor housing up to 40 bar (580 psi).
Transmitter features
Quality – designed for custody transfer; featuring worldwide recognized
metrological approvals. Flexible data transfer options – numerous
communication types. Automatic recovery of data for servicing. 4‐line
backlit display with touch control. Device in compact or remote version.
Nominal diameter range
DN 8 to 250 (⅜ to 10")
High temperature: DN 25 (1"), DN 50 (2"), DN 80 (3")
Wetted materials
Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602
(UNS N06022)
Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow,
reference density
2 Endress+Hauser
Promass 84F
Gas Max. measurement error
Mass flow (liquid): ±0.1 % (standard), 0.05 % (option)
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.35 %
Density (liquid): ±0.0005 g/cm³
Measuring range
0 to 2 200 000 kg/h (0 to 80 840 lb/min)
Max. process pressure
PN 100, Class 600, 63K
Medium temperature range
Standard: –50 to +200 °C (–58 to +392 °F)
High temperature: –50 to +350 °C (–58 to +662 °F)
Ambient temperature range
Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F)
Sensor housing material
1.4301/1.4307 (304L), corrosion resistant
Transmitter housing material
Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), cast
Degree of protection
IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
Display/Operation
4‐line backlit display with touch control
(operation from outside)
Configuration via local display and operating tools possible
3 Endress+Hauser
Promass 84F
Gas Outputs
4 modular outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive)
phase shifted pulse
Relay
Inputs
1 modular input: status
Digital communication
HART
Modbus RS485
Power supply
DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz)
Hazardous area approvals
ATEX, IECEx, FM, CSA, NEPSI
Other approvals and certificates
3.1 material, calibration performed on accredited calibration facilities
(acc. to ISO/IEC 17025), NAMUR, custody transfer, PED, CRN, AD 2000,
3-A, FDA, NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,
NORSOK
Product safety
CE, C-tick, EAC marking
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC
17025), NAMUR
Custody transfer approvals: MI-005 (liquid), PTB 7.251 (gas), MC
Pressure approvals and certificates
PED, CRN, AD 2000
4 Endress+Hauser
Promass 84F
Gas Material certificates
3.1 material
NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK
Hygienic approvals and certificates
3-A, FDA
Liquids Measuring principle
Coriolis
Product headline
The flowmeter with premium accuracy, robustness and custody transfer
functionality. Highest measurement performance for liquids and gases
under varying, demanding process conditions.
Sensor features
Highest process safety – immune to fluctuating and harsh environments.
Fewer process measuring points –multivariable measurement (flow,
density, temperature). Space‐saving installation – no in/outlet run
needs. Mass flow: measurement error ±0,05 % (PremiumCal). pressure-
rated sensor housing up to 40 bar (580 psi).
Transmitter features
Quality – designed for custody transfer; featuring worldwide recognized
metrological approvals. Flexible data transfer options – numerous
communication types. Automatic recovery of data for servicing. 4‐line
backlit display with touch control. Device in compact or remote version.
Nominal diameter range
DN 8 to 250 (⅜ to 10")
High temperature: DN 25 (1"), DN 50 (2"), DN 80 (3")
Wetted materials
Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602
(UNS N06022)
Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
5 Endress+Hauser
Promass 84F
Liquids Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow,
reference density
Max. measurement error
Mass flow (liquid): ±0.1 % (standard), 0.05 % (option)
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.35 %
Density (liquid): ±0.0005 g/cm³
Measuring range
0 to 2 200 000 kg/h (0 to 80 840 lb/min)
Max. process pressure
PN 100, Class 600, 63K
Medium temperature range
Standard: –50 to +200 °C (–58 to +392 °F)
High temperature: –50 to +350 °C (–58 to +662 °F)
Ambient temperature range
Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F)
Sensor housing material
1.4301/1.4307 (304L), corrosion resistant
Transmitter housing material
Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), cast
Degree of protection
IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
Display/Operation
4‐line backlit display with touch control
(operation from outside)
Configuration via local display and operating tools possible
6 Endress+Hauser
Promass 84F
Liquids Outputs
4 modular outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive)
phase shifted pulse
Relay
Inputs
1 modular input: status
Digital communication
HART
Modbus RS485
Power supply
DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz)
Hazardous area approvals
ATEX, IECEx, FM, CSA, NEPSI, EAC
Other approvals and certificates
3.1 material, calibration performed on accredited calibration facilities
(acc. to ISO/IEC 17025), NAMUR, custody transfer, PED, CRN, AD 2000,
3-A, FDA, NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,
NORSOK
Product safety
CE, C-tick, EAC marking
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC
17025), NAMUR
Custody transfer approvals: MI-005 (liquid), PTB 7.251 (gas), MC, NTEP
Pressure approvals and certificates
PED, CRN, AD 2000
7 Endress+Hauser
Promass 84F
Liquids Material certificates
3.1 material
NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK
Hygienic approvals and certificates
3-A, FDA
Density/Concentration Measuring principle
Coriolis
Product headline
The flowmeter with premium accuracy, robustness and custody transfer
functionality. Highest measurement performance for liquids and gases
under varying, demanding process conditions.
Sensor features
Highest process safety – immune to fluctuating and harsh environments.
Fewer process measuring points –multivariable measurement (flow,
density, temperature). Space‐saving installation – no in/outlet run
needs. Mass flow: measurement error ±0,05 % (PremiumCal). pressure-
rated sensor housing up to 40 bar (580 psi).
Transmitter features
Quality – designed for custody transfer; featuring worldwide recognized
metrological approvals. Flexible data transfer options – numerous
communication types. Automatic recovery of data for servicing. 4‐line
backlit display with touch control. Device in compact or remote version.
Nominal diameter range
DN 8 to 250 (⅜ to 10")
High temperature: DN 25 (1"), DN 50 (2"), DN 80 (3")
Wetted materials
Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602
(UNS N06022)
Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
8 Endress+Hauser
Promass 84F
Density/Concentration Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow,
reference density
Max. measurement error
Mass flow (liquid): ±0.1 % (standard), 0.05 % (option)
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.35 %
Density (liquid): ±0.0005 g/cm³
Measuring range
0 to 2 200 000 kg/h (0 to 80 840 lb/min)
Max. process pressure
PN 100, Class 600, 63K
Medium temperature range
Standard: –50 to +200 °C (–58 to +392 °F)
High temperature: –50 to +350 °C (–58 to +662 °F)
Ambient temperature range
Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F)
Sensor housing material
1.4301/1.4307 (304L), corrosion resistant
Transmitter housing material
Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), cast
Degree of protection
IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
Display/Operation
4‐line backlit display with touch control
(operation from outside)
Configuration via local display and operating tools possible
9 Endress+Hauser
Promass 84F
Density/Concentration Outputs
4 modular outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive)
phase shifted pulse
Relay
Inputs
1 modular input: status
Digital communication
HART
Modbus RS485
Power supply
DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz)
Hazardous area approvals
ATEX, IECEx, FM, CSA, NEPSI, EAC
Product safety
CE, C-tick, EAC marking
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC
17025), NAMUR Custody transfer approvals: MI-002 (gas), MI-005
(liquid), PTB 7.251 (gas), MC, NTEP
Pressure approvals and certificates
PED, CRN, AD 2000
Material certificates
3.1 material
NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK
10 Endress+Hauser
Promass 84F
Density/Concentration Hygienic approvals and certificates
3-A, FDA
Density Measuring principle
Coriolis
Characteristic / Application
Coriolis mass flowmeter for custody transfer application.
Ambient temperature
-20...+65°C
(-4...+140°F)
Process temperature
-50...+200°C
(-58...+392°F)
Process pressure absolute
PN 16...100
Cl 150...600
JIS 10...63K
Wetted parts
904L/1.4539
Alloy C-22/2.4602
Output
4...20mA
Pulse/Frequency (10KHz, 90° phase shifted, active/
passive)
Relays/Status
Certificates / Approvals
ATEX
FM
CSA
TIIS
11 Endress+Hauser
Promass 84F
Density
More information www.endress.com/84F
Endress+Hauser AG addresses.endress.com
Switzerland [email protected]