0% found this document useful (0 votes)
122 views18 pages

04 Thomas Louagie - Induced Draft ACCs

The document discusses SPG Dry Cooling products including air cooled condensers and coolers. It focuses on W-Style ACC induced draft air cooled condensers, describing their general principle, selection guidelines, and operational features like reduced wind sensitivity, decreased flow accelerated corrosion, improved access for maintenance, and cleaning from the air outlet side.

Uploaded by

Burak Gülen
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
122 views18 pages

04 Thomas Louagie - Induced Draft ACCs

The document discusses SPG Dry Cooling products including air cooled condensers and coolers. It focuses on W-Style ACC induced draft air cooled condensers, describing their general principle, selection guidelines, and operational features like reduced wind sensitivity, decreased flow accelerated corrosion, improved access for maintenance, and cleaning from the air outlet side.

Uploaded by

Burak Gülen
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 18

SPG DRY COOLING

Induced draft ACCs

MEMBER OF

Company Confidential
HISTORY & HERITAGE

1894 Founding Balcke

Aquired by
2002 SPG

1883 Founding Dürr


2016 Member of

Hamon DC
1904 Founding Hamon 2003 Acquired by SPG

SPG Dry Cooling


is an innovative Global Leader in Air Cooled Condensers & Coolers with the
largest installed base

2019

Company Confidential December 2017


GLOBAL NETWORK

Mexico, Mexico Monterrey, Mexico

Service Center

Company Confidential December 2017 3


W-STYLE ACC®
INDUCED DRAFT ACC

MEMBER OF

Company Confidential
SPG DRY COOLING PRODUCTS

Air cooled condenser (Mechanical Draft) A-Frame ACC

State of the art forced draft ACC with SRC© tubes


Other types of finned tubes available

SPG DC Unique and patented

BoxAir ACC® Hexacool® W-Style ACC® ModuleAir ®

Induced Draft Induced Draft Induced Draft Forced Draft


<30 MWe <50 MWe All size All size
High pre- assembly level
Standard Product

Induced draft family 5


FROM A-FRAME TO W-STYLE
A-Frame ACC WStyle ACC

Steam
Distribution
Manifold
Heat
Exchanger

6
W-STYLE ACC®
GENERAL PRINCIPLE

W-Style ACC® is an induced Draft Air Cooled Condenser, with a unique “W” heat
exchanger arrangement.
Features
• Each street with two steam distribution manifolds at the bottom.
• Heat Exchanger arranged in W with a typical tube length of ~6m.
• Concrete or steel understructure supporting ACC modules with a flexibility in foundation localization.

Company Confidential 10/25/2019 7


W-STYLE ACC®
GENERAL PRINCIPLE

Features
• Heat Exchanger with state of the art SRC© finned tubes
• Fan deck level with perpendicular shaft Gearbox, Motor, Fan, Fan Bell on top of the exchanger.
• Short Fan bridge supported in the middle by the central top manifold .
• Fan deck fully accessible for maintenance ; walking area between bundles above the steam manifold for
cleaning

Company Confidential 8
W-STYLE ACC®
GENERAL PRINCIPLE

Steam Distribution
• Distribution manifold under the heat exchangers
• Intermediate manifold at top of the heat exchangers. (common in the middle)
• Condensate collection from bottom manifold and condensate header

Top manifold

Bottom manifold

Steam

Company Confidential 9
INDUCED DRAFT ACC
SELECTION GUIDELINES

A-frame Hexacool W-Style BoxAir

Fan Forced Draft / Induced Draft / Induced Draft / Induced Draft /


Configuration 36ft 36ft 36ft 12ft
Layout No Line No Line
Limitation arrangement arrangement
Tube length ~11m ~11m ~6m ~2m

Pre-assembly Normal High Normal Very high


level
Capacity No < 50MW No < 30 MW
limitation

1
0
WHAT DOES IT IMPLY FOR
O&M ?

MEMBER OF

Company Confidential
W-STYLE ACC® : OPERATIONAL FEATURES
WIND SENSITIVITY IS REDUCED

Two main negative effects of wind on an ACC performances:


• Recirculation of hot air exiting the ACC.
With W-Style ACC in induced draft, recirculation is reduced due to higher exit air velocity

• Reduction of fan air flow due to disturbance at air inlet


With W-Style ACC the fan inlet is protected from cross wind by the bundles acting like a screen

12
W-STYLE ACC® : OPERATIONAL FEATURES
FLOW ACCELERATED CORROSION IS DECREASED

Classical A-Frame W-Style ACC Comments

Lower steam pressure drop


Heat exchanger Reduced overall height
arrangement Self supporting structure

2 x shorter tube [5.7m]

Long tube [11.4m]

#of Tubes ~6000 ~3000 About 2x more tubes with W

Tube cross
~219x19mm ~219x19mm Identical
section

Steam Velocity Steam velocities roughly follow the


~45 m/s ~28 m/s
@145mbar, 25°C tube number ratio

Steam Velocity
~70 m/s ~45 m/s
@94mbar, 15°C

Steam Velocity
~105 m/s ~73 m/s
@65mbar, 2°C

13
W-STYLE ACC® : OPERATIONAL FEATURES
LOWER PRESSURE AT LOW AMBIENT

Improve steam turbine output

14
W-STYLE ACC® : OPERATIONAL FEATURES
IMPROVED ACCESS FOR MAINTENANCE

Hoist to
ground level

W-Style: Access for maintenance

One platform giving access to all fans, motors and gearboxes


15
W-STYLE ACC® : OPERATIONAL FEATURES
CLEANING

Cleaning Cleaning
water water

Air

W-Style: cleaning from air outlet side

Cleaning opposite to air direction (as A-frame)


16
W-STYLE ACC® : OPERATIONAL FEATURES
CLEANING

Company Confidential 17
Q&A