0% found this document useful (0 votes)
48 views1 page

SHM126 Script

The document contains configuration settings for two communication channels (ct 1/3/1 and ct 1/3/2) with details such as frame ID, transmission and reception frequencies, output power, target input power, modulation schemes, and alarm thresholds. Both channels have a licensed capacity of 221000 and enable auto-remove loop functionality. The first channel uses vertical polarization while the second uses horizontal polarization.

Uploaded by

lucky chandel
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as TXT, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
48 views1 page

SHM126 Script

The document contains configuration settings for two communication channels (ct 1/3/1 and ct 1/3/2) with details such as frame ID, transmission and reception frequencies, output power, target input power, modulation schemes, and alarm thresholds. Both channels have a licensed capacity of 221000 and enable auto-remove loop functionality. The first channel uses vertical polarization while the second uses horizontal polarization.

Uploaded by

lucky chandel
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as TXT, PDF, TXT or read online on Scribd
You are on page 1/ 1

ct 1/3/1

frame-id 258
tx-frequency 14515000
rx-frequency 14935000
selected-output-power 15 15
target-input-power-far-end -40
selected-max-acm 1024_QAM
selected-min-acm 64_QAM
wanted-licensed-capacity 221000
reference-sec 7B
carrier-id A
polarization Vertical
input-power-alarm-threshold -93
ber-alarm-threshold 10e-6
auto-remove-loop enable
tx-admin-status on
exit

!
ct 1/3/2
frame-id 258
tx-frequency 14515000
rx-frequency 14935000
selected-output-power 15 15
target-input-power-far-end -40
selected-max-acm 1024_QAM
selected-min-acm 64_QAM
wanted-licensed-capacity 221000
reference-sec 7B
carrier-id B
polarization Horizontal
input-power-alarm-threshold -93
ber-alarm-threshold 10e-6
auto-remove-loop enable
tx-admin-status on
exit