Portable Phlegm Suction Manual

This document provides product specifications for a portable phlegm suction unit. It lists the key technical performances including high negative pressure and low flow. It also describes how to connect the unit to a power source and test that it is functioning properly by simulating suction of liquid and ensuring the float and valve move as expected. Commissioning steps are outlined to check for any abnormal sounds during operation and that vacuum pressure reaches the proper level.

Uploaded by

Zepo Depo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
181 views1 page

Portable Phlegm Suction Manual

This document provides product specifications for a portable phlegm suction unit. It lists the key technical performances including high negative pressure and low flow. It also describes how to connect the unit to a power source and test that it is functioning properly by simulating suction of liquid and ensuring the float and valve move as expected. Commissioning steps are outlined to check for any abnormal sounds during operation and that vacuum pressure reaches the proper level.

Uploaded by

Zepo Depo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Product Features 3. Main Technical Performances 3.

3. Main Technical Performances 3. Power line connection • Tighten the hold plug, attach the suction tube conductor at the inlet, and
① High negative pressure, low flow Connect the plug with the power source. Turn on the power supply, and screw firmly the regulating valve, then, actuate the aspirator.
1.General ② Power supply: □AC120V±10% □AC220VV±10% □AC240V±10% the power indicator will illuminate. • Put the suction conductor into one clean water pail or attempt to simulate
phlegm suction unit is a novel, portable, AC/DC powered medical suction, □50Hz □60Hz DC12V Note: The power plug is used for power shut-off, and the power socket actual application to suction the liquid into the holder of the overflow

Portable Phlegm Suction Unit which is suitable to use by the patient who has difficulty in phlegm removal ③ Input power: 65VA shall be grounded reliably. device. As a result, t he float will rise as the liquid level ascends until the
TABLE OF CONTENTS ④ Limit negative pressure: ≥0.075Mpa valve is closed and suction stops automatically. The final position of liquid
due to illness, coma and operation, as well as for aspirating such liquid as
⑤ Negative pressure regulating range: 0.02Mpa~limit negative pressrue
4. Connector inspection level depends on the suction process adopted.
pus and blood during the clinical practice. It is the commonly applied medical • Turn tightly the negative pressure regulating valve clockwise, and block the
device in the emergency room, operation room, and for nursing in sickroom ⑥ Suction rate: ≥ 15L/min • Release the regulating valve, set the aspirator switch off, open the holder
air suction inlet with the finger or the rubber head of dropper, or fold up plug and empty the liquid in the holder. The float shall be at the bottom of
and health care in patient transport and place without AC/DC. ⑦ Liquid storage bottle: 1000mL/pc,1pc
Product Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 and hold the suction tube. the support and the valve is in open status in case ofre-screwing firmly the
⑧ Noise: ≤ 65dB(A)
• Start the aspirator for running with no strange sound; the pointer of the
2.tructure & Working Principle ⑨ Net Weight: 5.2Kg
vacuum meter will quickly reach up to the limit negative pressure. Release
hold plug.
⑩ Dimension: 330x187x300(mm) If so, the overflow device is considered as being in normal condition, which
• Oil free lubrication pump to keep the environment from being polluted by the air suction inlet, the pointer will return below0.02Mpa.If so,the connector
InstalIing and Commissioning . . . . . . . . . . . . . . . . . .2 the oil mist. • The apparatus is not suitable for use in the place with inflammable & explosive can be regarded as being in good connection.
can be used for clinical practice.
gas. Note:
• Low noise. • Attach the phlegm suction catheter. The negative pressure in the negative
• Working system: short time running. ① The liquid level still continuously ascends after the overflow device
• Square negative pressure meter, and plastic cover. pressure system shall be less than 0.06MPa at the time of attaching F6
Application and Maintenance . . . . . . . . . . . . . . . . . 5 • No any positive pressure to be generated during running, to ensure reliable • Electric classification: Class Ⅱ equipment,Type B applied part. suction catheter, less than 0.04 MPa when attaching FB suction catheter and
has been shut off, possibly due to:
• Residual negative pressure still in the holder.
and safe operation. less than 0.03 MPa when attaching Fl2 suction catheter. If so, the phlegm
• Negative pressure regulating system can be adjusted steplessly .Small in size, 4. Normal Operating Conditions aspirator is considered as being in normal condition.
• Valve mouth not fully closed.
Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 • Ambient temperature: +5℃-+40℃ For Item ( 1 ), the liquid level in the holder will not ascend when the
light in weight and portable.
• Relative humidity: Note:Dredge the suction catheter if blocked as per the following suction tube conductor is placed again into the liquid as suctioned,
• Supplied with three kind of power supply: AC, external DC. and internal ≤80%
• Atmosphere pressure: 86kPa- 106kPa method: Bend the suction conductor in "V" form ( with no liquid in and for Item ( 2 ), the liquid level still ascends. Thus, it is required to
battery, continuous movement time≥0.5 hr when fully charged, rechargeable,
the holder ), and release it to the original status when the negative observe carefully, and lift immediately the conductor out of the
attach the unit to the car lighter ( DC l 2V ) by wire when use on the vehicles
such as ambulance. InstalIing and Commissioning pressure reaches up to the maximum value. Repeat this procedure suctioned liquid when the holder is close to full, then, switch off the
aspirator to stop suction, and examine the possible reason of the valve
• Charge method is constant current, and integral trickle type. When plugged several times till the catheter is not blocked.
fault.
into AC power, the internal battery maintenance control system will bright the 1.Open Package Inspection 5. Negative pressure regulating ② The float is still adhered on the valve mouth as already closed by
battery to full charge, illuminating the green light on the unit. • The customer shall carefully inspect if the appearance of product is good, and • Block the suction inlet, open the aspirator switch and regulate the negative the float, possibly due to the negative pressure in the line. At this
• The operating principle diagram shown as follows: the varieties & quantities of the attachments are in conformity with those as pressure valve, and the readings on the pressure meter shall be within 0.02 moment, release the regulating valve or shut off the aspirator (to
indicated in the attached list before installing and commissioning. Also, the MPa~ limit negative pressure. release the negative pressure in the line), the float will descends from
8 customer shall timely notify the supplier or manufacturer of damage (s) if any. the valve mouth under the action of gravity. (It is forbidden to pull the
September 2020 • Control the negative pressure as required for suction by means of the
5 2.Connecting( See Tube Connecting Diagram,with phlegm suction catheter negative pressure valve at the time of clinical practice. float with hand, in order to avoid the rubber valve clack being
separated from the float).
temporarily not connected ) • Increase the negative pressure by turning the valve clockwise
User's Manual 1 9 • Reduce the negative pressure below 0.02 MPa prior to power shut-off. ③ After shut-off, release the negative pressure, then, open the holder
plug;
4 7 6. Inspection & test on the overflow device ④ Never use the aspirator under the condition of the overflow device
2 • Open the holder plug; clean up the valve mouth, and leveling the rubber & the conductor dismantled.
Tube Connecting Diagram
3 6 10 valve clack on the float. The valve clack shall not be warped, bent and
Operating principle diagram
1. Suction tube 2. Air filter 3. "IN" mark broken, but well connected with the float. The float shall be able to move 7. Stop running
4. Suction conductor 5. Liquid storage bottle freely in its support without any blockage. Turn off the aspirator switch, and pull the power plug out of the socket to
1.Exhaust outlet 2.Suction inlet 3.Silencer 4.Vacuum pummp 6. To the phlegm suction catheter • Lift the holder plug with hand to make the float contact the water surface shut off the power supply.
Please read the user's manual closely before using! 5.Negative pressure regulating vavle 6.Overflow valve 7.To phlegm Note: Apply small amount of distilled water around the part (pressed perpendicularly gradually lower the holder cover to let the float rise.
suction catheter 8.Vacuum meter 9.Air filter 10.Liquid holder intothe holder mouth) of holder plug during installing, which is good
for tightly pressing the holder plug and enhancing its sealing.
1 2 3 4

8. Symbols
4. Changing the fuse tube 6. Trouble shooting Precautions 4. Attachments
Symbols Meaning Symbols Meaning • The fuse tube is mounted at the rear of the base. Switch off the power supply, • Suctlion conductor ( Ф7X12,length 2m ): 1 PC
and turn it counterclockwise and open, then, start changing the tube. • Air filter: 2 PCS
~ Alternating current Consult the manual Problem Probable Reason Solution Remark 1. Transportation and storage conditios • Fuse tube □ F1.5AL250VФ5X20 2 PCS
5. Maintenance • Ambient temperature: -40℃-+55℃ □ F2AL250VФ5X20 2 PCS
OFF ON • It is recommended to have the suction tube suctioned small amount of clean a. Remove dirt, tighten
• Relative humidity: ≤93% T3.15AL250VФ5X20 2 PCS
water for cleaning up the inner wall before switching off the aspirator. a. Holder mouth or change the holder • Atmosphere pressure: 70kPa- 106kPa
• After use, empty the holder, clean up dirt on the holder and plug with soft leakage cover, seal ring, and
1 Limit negative b. Leakage on Change the Note: • Suction catheter 1 pc respectively of child & adult
brush or rag, flush it with water and conduct sterilization. including the
Application and Maintenance overflow device, the seal ring and various tubes. Unscrew the overflow device,
pressure<0.06 connecting points
connector
b. Re - tighten each
broken suction It is required to store the aspirator in the well-ventilated room without • Instruction manual 1 pc
Mpa c. Regulating valve catheter corrosive gas, and avoid any violent shock while handling.
and separate the float from its support for completely cleaning up, if connection point
1.Usage of battery necessary.
loose or released c. Turn tightly the 5. To dispose the castoff
Please check the internal battery if it is charged fully before using. regulating valve
• Connect the power cord to a properly grounded AC outlet the charging
Note: The rubber valve clack shall not be separated from the float. 2. Electric and magnetic environment guidance in use The castoff should be disposed in accordance with all applicable
• Use the physiological saline to clean out the residual strong phlegm and • The Portable Phlegm Suction Unit uses RF energy only for its internal
light is bright shows the power supply and charges internal battery. The a. Afte shut-off, turn the government regulations.
mucus in the tube after used. Replace the suction catheter if not smooth. It is Negative function. Therefore, its RF emissions are very low and are not likely to cause
charging light gleams to mean the battery charging fully. recommended to adopt one-time suction catheter. regulating valve loose
pressure>0.04 any interference in nearby electronic equipment.
• Break net power, then use the internal battery. • Place the holder, cover and all tubes into the disinfectant compounded with Mpa,wich
counterclockwise to
Empty the holder
release negative • The Portable Phlegm Suction Unit is suitable for use in all establishments,
• The internal battery shall be charged fully about 5 hr when it was been used the Kangweida disinfector tablets (0.5g per tablet) in l :500 concentration for distinct timely
pressure in tube, including domestic and those directly connected to the public low-voltage All specifications and product configurations are s ubject to change
up (the red light is bright). The internal used battery is charged according to l hour. reduction or The end (in blue
2 then re-screw power supply network that supplies buildings used for domestic purposes. without notification.
residual power capacity in order to power capacity is full. Note: Keep the glass holder away from any sharp utensils to avoid drop disappearing a. Loose socket mark) of air filter
b. Dredge, clean or
is the air inlet
• Due to the fact that the Electric Suction Apparatus contains no electronic
• The internal battery shall be charged and discharged once a month to in the process of cleaning and application. of suction b. Fuse broken
replace the tube
force at tube c. Indicator damaged control circuitry, they are deemed to fulfill the relevant immunity
maintain if it was not use for a long time. • Wipe the case outer surface with lightly wet rag already soaked in the c. Replace it with air filter
outlet requirements without testing.
Note: disinfectant, and prevent any liquid seeping into the pump. Never wipe the produced by us • The Portable Phlegm Suction Unit was not tested f or immunity to
The unit has internal charger and shall be not used any other places marked with letters and patterns. electromagnetic disturbances.
specification battery. The battery shall be not used over30minutes once. • Place the machine in dry and clean places, and periodically start running Normal power
voltage. but a. Loose socket a. Repair or change
once a time ( normally one time every 6 months ). the socket Refer to
2.The power for car lighter (DC 12V) Note: Install the overflow device, conductor and other tubes as per the 3 the indicator b. Fuse broken
b. Replace the fuse tube attachments 3. Electric systematic diagram
doesn't c. Indicator damaged
• Attach car lighter plug to the connector in the back of the unit and insert the connecting mode before re-use. illuminate c. Replace the indicator
car lighter cord to the socket when the unit was used to in patient transport. Charging indicator Refill indicator
The light of car lighter is bright to mean that the DC power supply.
By the
3.Changing air filter specialized Battery
a. Voltage over high
• It is required to change air filter with the one produced by us in case of foam b. Internal line in fault
a. Adjust voltage
maintenance FU FU
Fuse tube b. Check the circuit line,
or dusts fully accumulated in the air filter, which leads to gradually darkening 4 3. Pump blocked, and worker(Refer
broken and correct
of the color of filter diaphragm and obviously reducing or even disappearing
of suction force at the inlet of tube while the negative pressure indicated on
current increasing c. Check the pump body
and motor
to Electric
Systematic ~ S
Diagram)
the vacuum meter climbs up to 0.04 MPa or more. DC monitor
Transformer Circuit board
Note ①:The suction force will diminish or disappear, and the negative
pressure ascend if the overflow device is closed, and the tube blocked Note:
12V
in the process of application. Please refer to "trouble Shooting". The dismantling & repair on the pump body if fault shall be conducted
Note ②:Necessary to frequently change air filter and destroy it centrally. by the specialized worker. Please contact the manufacturer if required. Electric Systematic Diagram

5 6 7 8 9

You might also like