Ultrasonic Sensors
BUS Q80K0-PWXER-600-S92K
BUS000A
1) Active surface 2) Housing 3) Top cover 4) Function indicator yellow 5) Display echo green
Ultrasonic sensor
Hysteresis and window function
General attributes Switching frequency f 0.5 Hz
Enclosure Type per IEC 60529 IP65 Switching output 2xPNP NO/NC
Indicator Echo LED green Ultrasonic frequency ca. 80 kHz
Indicator switching function LED yellow
Polarity reversal protected yes Mechanical attributes
Protection Class II Connector type M12x1 5 poles
Setting Remote Cover material Plastic PA
Short circuit protected yes Housing material Plastic PBT
Opening angle, sound cone 8°
Electrical attributes Operating temperature max. +70 °C
Connection type Connector Operating temperature min. -15 °C
Current draw ≤60 mA Range max. 5000 mm
Eff. operating voltage Ue DC 24 V ±25 % Range min. 600 mm
Hysteresis H max. 1% Repeat accuracy 0.2 %
Operating voltage UB max. DC 30 V DC Resolution 1.000 mm
Operating voltage UB min. DC 12 V DC Sensing face material Epoxide hollow glass spheres
Output current max. 500 mA Storage temperature max. +75 °C
Output signal adjustable yes Storage temperature min. -30 °C
Stability EN 61000-4-3 Temperature compensation yes
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-2
PIN 1: +24V
PIN 2: Output 2
PIN 3: 0V
PIN 4 Output 1
PIN 5: Teach-in
Internet www.balluff.com For definitions of terms, see main catalog BUS000A_178850_05/10/141(1)
Balluff Germany +49 (0) 7158 173-0, 173-370 Subject to change
Balluff USA 1-800-543-8390
Balluff China +86 (0) 21-50 644131