DATASHEET

SPC PRO
SN-SPCP-FWL1 INDOOR DUAL-TECH SHOCK SENSORS

Detector for walls


Compliance
ƒ Directive 2014/30/UE (EMC)
Ì EN 50130-4:2011+A1:2014
Ì EN 61000-6-3:2007+A1:2011
ƒ Directive 2011/65/UE (ROHS)
Ì EN 50581:2012

Technical featrures
ƒ Security grading: Grade 3 (in accordance with EN 50131-2-8)
ƒ Environmental class: Class II (in accordance with EN 50131)
ƒ Dimensions: 89 x 89 x 20 mm (L x H x D)
ƒ Pack dimensions: 90 x 130 x 35 mm (L x H x D)
ƒ Gross weight: 72 g
ƒ Net weight: 53 g
P/N SN-SPCP-FWL1 ƒ Case material: ABS
ƒ Colour: white

DESCRIPTION ƒ Power supply: 12 Vdc (±25%) (nominal)


8V (low supply voltage)
DEA Sensor Fusion (DSF) addressed shock detector for the protection ƒ Current: 25 mA
of any type of wall against low attacks, gross attacks, heavy attacks 37 mA max (during calibration)
and continuous impacts. DSF technology combines the robustness and ƒ Operating temperature: -20 °C ÷ +70 °C (not certified)
reliability of the piezoelectric transducer and the MEMS accelerometer ƒ Relative humidity: <95% non condensing
with an integrated electronics which guarantees timely detection and
ƒ IP rating: IP40
sensor adjustment.
Configuration and calibration are performed by a Wi-fi dongle (DG-DEA- ƒ Functions and devices: anti-removal and anti-opening tamper
WF2) to connect to the detector and a mobile APP (iOS/Android). ƒ Inputs: Reset and ARM (for alarm memory)
ƒ Outputs (NC):
PACKAGE CONTENTS Ì alarm line (continuous impacts, low attacks,
gross attacks and heavy attacks)
In addition to the datasheet herein, the package contains: Ì power fail
ƒ 1 no sensor ƒ 2 no cable glands and 2 no cable- Ì tamper line
ƒ 4 no round head self-tapping housing grommet ƒ Communication: connector for Wi-Fi dongle
screws 2,5 x 95 mm and plugs ƒ 1 no unlocking tool
ƒ 1 no mini screwdriver ƒ Average coverage area: 4 m2 (custom mode)
ƒ Configuration via SPC PRO APP

COVERAGE AREA ƒ Mobile App licence (iOS/Android) included


(*) Can vary depending on the dimension, material and type of structure.
The detector varies its performance depending on the material of the
protected structure. Under custom mode, the coverage area results to
be:
SENSOR MAXIMUM
STRUCTURE
DISTANCE
COVERAGE AREA
Dimensional scheme
89
Armoured concrete wall
6m 46 m2
(45 cm min. thickness)

Armoured concrete wall


5m 31 m2
(20 cm min. thickness)

double UNI wall


4m 20 m2
(30 cm min. thickness)
65
89

Tuff wall
3m 11 m2
(30 cm min. thickness)

COVERAGE AREA
65
20

Application example

sensor distance

SPCPRO APP (Android version) must be downloaded


on www.deasecurity.com/shorturl/1a1he or scanning QRCODE.
INSTALLATION CONNECTIONS
To install the sensor, you need: The detector is equipped with a 8-way terminal block: 12 VDC power
supply (1 and 2), optional RESET and ARM inputs (3 and 4), alarm
output (5 and 6) and tamper output (7 and 8).
1
D ATASHEET

1 2 3 4 5 6 7 8

POWER SUPPLY
TAMPER output
12 VDC (+/-25%)
ARM memory ALARM output
RESET input and POWER fail

3 CONNECTIONS BETWEEN OUTPUTS AND CONTROL PANEL MUST BE


2 PERFORMED USING A SHIELDED CABLE

AFTER POWERING THE SENSOR, WAIT FOR THE INITIALIZATION FUNCTIONAL


CHECKS. AT THIS STAGE THE SENSOR MUST BE FIXED. ONCE INITIALIZATION
IS COMPLETE, THE LED SIGNALS CORRECT OPERATION (BLUE FLASHES) OR
MALFUNCTIONS (MAGENTA FLASHES).

CALIBRATION
Calibration and confi-
guration of the system
SPC PRO

occurs by means of SPC


PRO app for iOS/Android
devices and the Wi-Fi
dongle connected to the
1. To open the detector, put off the light guide on the cover (1), insert detector (please see DG-
the unlocking tool in the two holes and raise the cover; DEA-WF2 technical data-
2. make the connection cable pass through the holes present on the sheet).
base of the sensor or on the side with the hollow, opening the pier-
ced sections. In this case:
Ì insert the cable in the cable gland supplied, with the body ƒ Wi-Fi CONNECTION
towards the inside of the sensor, slotting it in the pierced To establish communication between device
section of the sensor; (smartphone, tablet) and detector, you need to
follow the following steps:
Ì iinsert DG-DEA-WF2 dongle in the detector;
Ì activate a Wi-Fi communication on the device
used;
Ì connect to DEA SECURITY Wi-Fi network;
Ì execute SPCPRO application;
Ì connect to the detector by clicking on Connection;
Ì insert password "123456".
ƒ Home App
In home you can check the information
Ì if flexible metal tube is used, turn the body of the cable gland
about the detector status (1, 2, 3 and 5) and/
outwards, insert the cable in the cable gland slotting it in the
or start calibration actions (4):
pierced section of the sensor. Insert the special cover on the
1. firmware and parameter version;
external side, using the joint of the cable gland;
2. save configuration;
3. monitor power supply;
4. modify configuration and various options;
5. sensor status icons. 1
2
SN-SPCP-FWL1

By clicking on the icon Settings, it is 3


possible to enter configuration and 4
calibration sections. 5

ƒ CALIBRATION to EN 50131-2-8
It is possible choose three presets
corresponding to three settings EN50131-
2-8 compliant:
3. fix the sensor to the wall with the screws and the plugs supplied; Ì window (general structure with glass,
4. wire the terminal board; default set);
5. if the surface of the structure to protect is irregular, use FP-FWL Ì wood (wooden plate);
metal plate to be wall mounted with a single central screw. If the Ì concrete (concrete plate).
sensor is installed on reinforced metal structures, the plate shall be After selecting the desired preset with the
welded in the 4 dedicated eyelets. right arrow (see picture), you go to Other
options.

2
ƒ CUSTOM CALIBRATION
Custom mode enables you to customize the calibration depending on the different intrusion techniques and to better fit the structure to protect.
After selecting Custom setting with the right arrow (see picture), you go to calibration.

D ATASHEET
ƒ CONTINUOUS IMPACTS ƒ GROSS ATTACKS
Custom mode enables Significant intensity event
you to customize the cali- but which does not com-
bration depending on the promise the integrity of the
different intrusion techni- structure.
ques and to better fit the Continuos Impact 1. enable the detection of
Gross Attack
structure to protect. GROSS ATTACKS;
After selecting Custom set-
1 1
2. set the event number
2
ting with the right arrow 2 desired to trigger the
(see picture), you go to ca- alarm;
libration. 3 3. set the memory time of 5
1. enable detection the event counting;
C O N T I N U O U S 4. set the desired 3
IMPACTS; 4 sensitivity, then check
2. set the event number it on the structure
desired (series of by generating gross 4
continuous impacts) to attacks on the latter
trigger the alarm; until the programmed
3. set the memory time of event number
the event counting; progresses in the
4. the default sensitivity is counter.
suitable for most of the
structures. If needed,
it can be adjusted
from minimum (0) to
maximum (100).

SPC PRO
IF THE SENSITIVITY LEVELS DO NOT MEET THE CALIBRATION
NEEDS, MODIFY THE ADAPTABILITY PARAMETER (5).

ƒ LOW ATTACKS ƒ HEAVY ATTACKS


Contact between the pro- Very high intensity attack
tected structure and a rigid which compromises the
body but which does not integrity of the structure
compromise the integrity and which must trigger an
of the structure itself. Low Attack immediate alarm. Heavy Attack
1. enable detection of 1 1. enable the detection of
LOW ATTACKS; HEAVY ATTACKS;
1
2. set the event number 2 2. the default sensitivity is
desired to trigger an suitable for most of the
5 structures. If needed,
2
allarm;
3. set the memory time of it can be calibrated
the event counting; from minimum (0) to
3 maximum (100).
4. adjust the sensitivity,
then check it on the
structure by simulating 4
low attacks with a rigid
body (for example with
SN-SPCP-FWL1

a hammer) until the


programmed number
of events progresses in
the counter.

IF THE SENSITIVITY LEVELS DO NOT MEET THE CALIBRATION NEEDS, IF THE SENSITIVITY LEVELS DO NOT MEET THE CALIBRATION NEEDS,
MODIFY THE ADAPTABILITY PARAMETER (5). MODIFY THE ADAPTABILITY PARAMETER (5).

3
SPC PRO
INDOOR DUAL-TECH SHOCK SENSORS
D ATASHEET

ƒ OTHER OPTIONS STATUS LED


Ì View Alarms on LED
The sensor is equipped with a multicolor LED, visible from the central
Ì View prealarms on LED lens, for status signalling:
Ì Enable Actibvity LED
LED COLOUR SENSOR STATUS
Ì Enable Tamper
Ì Enable Audio Blue REGULAR ACTIVITY
Ì Enable Reset: making the Magenta fixed Tamper
terminal board connection,
Red Alarm
enable the digital input
command 1, inhibiting the White Prealarm
sensor alarm output. Purple INITIALIZATION ERROR
Ì Enable Memory: making the
terminal board connection,
enables the digital input
command 2, activating the
sensor alarm memory.
Ì Save preset
Ì Self-test
Ì Password:change password

STATUS ICONS
The SPC PRO APP communicates the sensor status in real time, throu-
gh the status icons, according to the following tables:
(RED) COMMUNICATION DISABLED

(GREEN) SENSOR ENABLED

(ORANGE) PREALARM

(RED) ALARM LOW ATTACKS

(RED) ALARM GROSS ATTACKS

(RED) ALARM HEAVY ATTACKS

(RED) ALARM CONTINUOUS IMPACTS

(MAGENTA) LOW VOLTAGE

(MAGENTA) SELF-TEST FAILED

(MAGENTA) MEMS SELF-TEST FAILED

(MAGENTA) SENSOR REMOVAL


SN-SPCP-FWL1

DEA Security S.r.l.


Via Bolano, snc - 19037 Santo Stefano di Magra (SP) - tel. +39 0187 699233 - fax +39 0187 697615
VAT NO.: IT00291080455
www.deasecurity.com - [email protected]
© 2021 DEA Security S.r.l. - Edition September 2021 - v. 1.0.1.
DEA Security srl reserve the right to change at any time and without notice the features of its products.

You might also like