OUR DIFFERENCE?

THE DETAIL.

S3

S5

S4
Fitted with
CoreCooling™
technology
The S4 Nomenclature

S 4 L 1 D G 4 1

Character Brand Family Series Voltage Revision Descriptor Core Length Pole Bearing

L = Low D = Dedicated
Examples STAMFORD 1/2/3/4/5 etc M = Medium 1 S = Special C/D/E/F/G 4 1/2
H = High M = Marine
The New S4 Dedicated

Enhanced thermal
management

Optimised
power
density core

New core length, 450kVA

Adaptor foot option, enabling


switching between S4 & S5

Flexible foot option, enabling switching


between alternative brands

Product evolution through technological revolution.


Our new CoreCooling™ technology results in improved thermal performance
and increased power density... it’s in the detail.
S4 Dedicated Ratings
50Hz 60Hz
Class H 125/40 Class H 125/40
Winding Number 311 Winding Number 311
Volts 380 400 415 Volts 416 440 480

Model kW kVA kW kVA kW kVA Model kW kVA kW kVA kW kVA

S4L1D-C41 200 250 208 260 208 260 S4L1D-C41 230 288 248 310 260 325

S4L1D-D41 240 300 248 310 248 310 S4L1D-D41 275 344 296 370 312 390

S4L1D-E41 280 350 288 360 288 360 S4L1D-E41 320 400 348 435 364 455

S4L1D-F41 320 400 332 415 332 415 S4L1D-F41 364 455 400 500 416 520

S4L1D-G41 344 430 360 450 360 450 S4L1D-G41 400 500 428 535 448 560

Standby 150/40 Standby 150/40


Winding Number 311 Winding Number 311
Volts 380 400 415 Volts 416 440 480

Model kW kVA kW kVA kW kVA Model kW kVA kW kVA kW kVA

S4L1D-C41 216 270 224 280 224 280 S4L1D-C41 240 300 264 330 280 350

S4L1D-D41 256 320 264 330 264 330 S4L1D-D41 292 365 320 400 332 415

S4L1D-E41 296 370 308 385 308 385 S4L1D-E41 336 420 368 460 380 475

S4L1D-F41 332 415 356 445 356 445 S4L1D-F41 388 485 428 535 444 555

S4L1D-G41 364 455 384 480 384 480 S4L1D-G41 428 535 460 575 480 600

Standby 163/27 Standby 163/27


Winding Number 311 Winding Number 311
Volts 380 400 415 Volts 416 440 480

Model kW kVA kW kVA kW kVA Model kW kVA kW kVA kW kVA

S4L1D-C41 220 275 228 285 228 285 S4L1D-C41 248 310 276 345 284 355

S4L1D-D41 264 330 272 340 272 340 S4L1D-D41 300 375 328 410 344 430

S4L1D-E41 304 380 332 415 320 400 S4L1D-E41 348 435 376 470 392 490

S4L1D-F41 340 425 372 465 364 455 S4L1D-F41 400 500 440 550 460 575

S4L1D-G41 380 475 400 500 400 500 S4L1D-G41 452 565 480 600 500 625

1292 WITH P.M.

450
598 617
851
Ø 620

315

508 CRS
457 CRS 232 641
Specification Accessories
MODEL S4-Dedicated Factory Build Options
Ratings at 50Hz (kVA) Class H 250-450 Anti-Condensation Heater (with Terminal Box)

Ratings at 60Hz (kVA) Class H 288-560 Quadrature Droop kit

Specifications Bearing RTD (Each Bearing)

Voltage Range 380-480 Air Inlet Filter

Poles 4 Drip Proof Louvres

Technology Wire Wound Remote Voltage Trimmer

AVR Analogue Radio frequency interference (RFI) Suppressor Kit

Voltage Sensing 2 Phase Excitation Loss Module

Bearing Arrangement Single Diode Failure Detector

SAE Adaptors SAE 1 CSA Approval

Terminals 12

Material Insulation Class H Available With MX321 MX341 AS440

Excitation System Self Exciting Current Sensing Kit ✓ ✓ ✓


Ingress Protection IP23 Controlled Short Circuit ✓ ✗ ✗
Connection with other machines Paralleling capability Manual Voltage Regulator ✓ ✓ ✗
Optional Features Frequency Detection Module ✓ ✓ ✗
Bearing Arrangement – Power Factor Controller - PFC3 ✓ ✓ ✓
SAE Adaptors 0.5 Remote Control Interface ✓ ✓ ✓
Excitation System PMG Excitation Circuit Breaker ✓ ✓ ✓
Ingress Protection IP23 Air Filters Dual AVR ✓ ✓ ✗
Output Configurations 1 Phase Reconnectable

Voltage sensing 3 Phase sensing Voltage Regulator Options PMG


Temperature Monitoring Winding RTDs AS440 AVR ✗
Temperature Monitoring Thermistors
MX341 ✓
Anti-Condensation
Environmental Protection MX321 AVR
Heater ✓
Adaptor Feet ✓ UL AS440 ✗
Flexible Feet ✓ UL MX341 ✓
Prime Movers No AVR ✓
Diesel Engine ✓
Gas Engine ✓

*GA drawings are indicative of S4-G Core dimensions


**Please contact our applications department for additional voltages that are available ([email protected])
S4 Special Ratings
50Hz 60Hz
Class H 125/40 Class H 125/40
Winding Number 311 Winding Number 311
Volts 380 400 415 Volts 416 440 480

Model kW kVA kW kVA kW kVA Model kW kVA kW kVA kW kVA

S4L1S-C41 200 250 200 250 200 250 S4L1S-C41 230 288 240 300 252 315

S4L1S-D41 240 300 240 300 240 300 S4L1S-D41 275 344 288 360 300 375

S4L1S-E41 280 350 280 350 280 350 S4L1S-E41 320 400 336 420 352 440

S4L1S-F41 320 400 320 400 320 400 S4L1S-F41 364 455 384 480 400 500

Standby 150/40 Standby 150/40


Winding Number 311 Winding Number 311
Volts 380 400 415 Volts 416 440 480

Model kW kVA kW kVA kW kVA Model kW kVA kW kVA kW kVA

S4L1S-C41 216 270 216 270 216 270 S4L1S-C41 240 300 256 320 268 335

S4L1S-D41 256 320 256 320 256 320 S4L1S-D41 292 365 308 385 320 400

S4L1S-E41 296 370 296 370 296 370 S4L1S-E41 336 420 356 445 368 460

S4L1S-F41 332 415 344 430 344 430 S4L1S-F41 388 485 412 515 428 535

Standby 163/27 Standby 163/27


Winding Number 311 Winding Number 311
Volts 1339 380 400 415 578 Volts 416 440 480
457 257 21.5 450
Model kW kVA kW
232 kVA kW kVA Model kW kVA kW kVA kW kVA
508

S4L1S-C41 220 275 220 275 220 275 S4L1S-C41 ON PCD 530 248 310 264 330 276 345
315

12 x Ø 12.7 THRO’
S4L1S-D41 264 330 264 330 264 330 S4L1S-D41 300 375 316 395 332 415
Ø 466.6

S4L1S-E41 304 380 320 400 304 380 S4L1S-E41 348 435 364 455 380 475
638

617
15°

ON PCD 438
30°

638
8 x Ø 13.5 THRO’
S4L1S-F41 400 500 424 530 440 550
846.1

S4L1S-F41 340 425 360 450 352 440


55

LIFTING EYE
(457) 40

452
CD LIFTING EYE 577
452
577 CD LIFTING EYE
CD LIFTING EYE
452

40 (457)
LIFTING EYE
40
LIFTING EYE
55

846.1

55

8 x Ø 13.5 THRO’

846.1
30°

Ø 466.6
15°

ON PCD 438
617

638

8 x Ø 13.5 THRO’
30°

Ø 466.6
ON PCD 438 15°
315

12 x Ø 12.7 THRO’
ON PCD 530
315
12 x Ø 12.7 THRO’
508

ON PCD 530
232
450 21.5 257 457
578 232
1339
21.5 257
578
Specification Accessories
MODEL S4-Special Factory Build Options
Ratings at 50Hz (kVA) Class H 250-400 Anti-Condensation Heater (with Terminal Box)

Ratings at 60Hz (kVA) Class H 288-500 Quadrature Droop kit

Specifications Bearing RTD (Each Bearing)

Voltage Range 380-690 Air Inlet Filter

Poles 4 Drip Proof Louvres

Technology Wire Wound Remote Voltage Trimmer

AVR Analogue Radio frequency interference (RFI) Suppressor Kit

Voltage Sensing 2 Phase Excitation Loss Module

Bearing Arrangement Single Diode Failure Detector

SAE Adaptors SAE 1 CSA Approval

Terminals 12

Material Insulation Class H Available With MX321 MX341 AS440

Excitation System Self Exciting Current Sensing Kit ✓ ✓ ✓


Ingress Protection IP23 Controlled Short Circuit ✓ ✗ ✗
Connection with other machines Paralleling capability Manual Voltage Regulator ✓ ✓ ✗
Optional Features Frequency Detection Module ✓ ✓ ✗
Bearing Arrangement Double Power Factor Controller - PFC3 ✓ ✓ ✓
SAE Adaptors 0.5, 0, 2, 3 Remote Control Interface ✓ ✓ ✓
Excitation System PMG Excitation Circuit Breaker ✓ ✓ ✓
Ingress Protection IP23 Air Filters Dual AVR ✓ ✓ ✗
Output Configurations 1 Phase Reconnectable

Voltage sensing 3 Phase sensing Voltage Regulator Options PMG


Temperature Monitoring Winding RTDs AS440 AVR ✗
Temperature Monitoring Thermistors
MX341 ✓
Anti-Condensation
Environmental Protection MX321 AVR
Heater ✓
Adaptor Feet ✗ UL AS440 ✗
Flexible Feet ✗ UL MX341 ✓
Prime Movers No AVR ✗
Diesel Engine ✓ No AVR ✓
Gas Engine ✓

*GA drawings are indicative of S4-F core dimensions


**Please contact our applications department for additional voltages that are available ([email protected])
S4 Marine Ratings
50Hz 60Hz
Class B (70°c) Temperature Rise, Continuous, 50°C Ambient Class B (70°c) Temperature Rise, Continuous, 50°C Ambient
Winding Number 311 Winding Number 311
Volts 380 400 415 Volts 440 460 480

Model kW kVA kW kVA kW kVA Model kW kVA kW kVA kW kVA

S4L1M-C41 148 185 148 185 148 185 S4L1M-C41 172 215 176 220 180 225

S4L1M-D41 160 200 160 200 160 200 S4L1M-D41 188 235 200 250 208 260

S4L1M-E41 192 240 192 240 192 240 S4L1M-E41 228 285 236 295 244 305

S4L1M-F41 220 275 220 275 220 275 S4L1M-F41 264 330 268 335 276 345

Class F (90°c) Temperature Rise, Continuous, 50°C Ambient Class F (90°c) Temperature Rise, Continuous, 50°C Ambient
Winding Number 311 Winding Number 311
Volts 380 400 415 Volts 440 460 480

Model kW kVA kW kVA kW kVA Model kW kVA kW kVA kW kVA

S4L1M-C41 168 210 168 210 168 210 S4L1M-C41 196 245 200 250 204 255

S4L1M-D41 184 230 184 230 184 230 S4L1M-D41 216 270 224 280 236 295

S4L1M-E41 220 275 220 275 220 275 S4L1M-E41 260 325 272 340 276 345

S4L1M-F41 248 310 248 310 248 310 S4L1M-F41 300 375 304 380 316 395

Class H (110°c) Temperature Rise, Continuous, 50°C Ambient Class H (110°c) Temperature Rise, Continuous, 50°C Ambient
Winding Number 311 Winding Number 311
Volts 380 400 415 Volts 440 460 480

Model kW kVA kW kVA kW kVA Model kW kVA kW kVA kW kVA

S4L1M-C41 172 215 172 215 172 215 S4L1M-C41 208 260 212 265 216 270

S4L1M-D41 192 240 192 240 192 240 S4L1M-D41 244 305 256 320 264 330

S4L1M-E41 236 295 236 295 236 295 S4L1M-E41 280 350 292 365 296 370

S4L1M-F41 272 340 272 340 272 340 S4L1M-F41 324 405 332 415 340 425

776 LOUVRES
1262 WITH P.M.G
617
451 583

8xø13.5 THRO’
ON PCD 438
537

852

45°
30°
ø466.6

15°
ø613

15°

315

12xø12.7 THRO’
ON PCD 530

457 CRS 232 508 CRS


578
632
Specification Accessories
MODEL S4-Marine Factory Build Options
Ratings at 50Hz (kVA) Class H 200-340 Anti-Condensation Heater (with Terminal Box)

Ratings at 60Hz (kVA) Class H 235-440 Quadrature Droop kit

Specifications Bearing RTD (Each Bearing)

Voltage Range 380-690 Air Inlet Filter

Poles 4 Drip Proof Louvres

Technology Wire Wound Remote Voltage Trimmer

AVR Analogue Radio frequency interference (RFI) Suppressor Kit

Voltage Sensing 2 Phase Excitation Loss Module

Bearing Arrangement Single Diode Failure Detector

SAE Adaptors SAE 1 CSA Approval

Terminals 12

Material Insulation Class H Available With MX321 MX341

Excitation System Self Exciting Current Sensing Kit ✓ ✓


Ingress Protection IP23 Controlled Short Circuit ✓ ✗
Connection with other machines Paralleling capability Manual Voltage Regulator ✓ ✓
Optional Features Frequency Detection Module ✓ ✓
Bearing Arrangement Double Power Factor Controller - PFC3 ✓ ✓
SAE Adaptors 0.5, 0, 2, 3 Remote Control Interface ✓ ✓
Excitation System PMG Excitation Circuit Breaker ✓ ✓
Ingress Protection IP23 Air Filters Dual AVR ✓ ✓
Output Configurations 1 Phase Reconnectable

Voltage sensing 3 Phase sensing Voltage Regulator Options PMG


Temperature Monitoring Winding RTDs MX341 ✓
Temperature Monitoring Thermistors
MX321 AVR ✓
Anti-Condensation
Environmental Protection UL MX341
Heater ✓
Adaptor Feet ✗ No AVR ✓
Flexible Feet ✗
Prime Movers
Diesel Engine ✓
Gas Engine ✓

*GA drawings are indicative of S4-F core dimensions


**Please contact our applications department for additional voltages that are available ([email protected])
PRODUCT HERITAGE
1973
World’s
First alternator
to utilise a PMG
for AVR excitation

1950
World’s 1966
First regulating C Range
alternator 1973
AC Range
produced
1966
World’s First
volume produced
brushless
alternator

1958
World’s First
rotating field
alternator
produced
2007 2016
P0/P1
S Range
Range

1988 2004
UC Range P7 Range
2016
S0/S1
Range

1985 1992
HC Range BC Range
For more information visit us at
stamford-avk.com

Follow us @stamfordavk

/company/stamfordavk

STAMFORDAvK

youtube.com/stamfordavk

stamford-avk.com
Copyright 2016, Cummins Generator Technologies Ltd. All rights reserved.
STAMFORD is a registered trademark of Cummins Generator Technologies Ltd.

Part No. PB_S4_EN/AF_Rev.3

You might also like