OTIS Software Basic Data No.
:
G1530780AAAG21xxAAxx30
780DBAAB_REF
Engineering Center SCN:
Berlin GGCS - GECB G1530780AAAG2xxAAAA13x
x130780BDCAAB
Service Tool Reference List
Page: 2 /
21121211112116161
Date: 2005-072007U-04-
05bd tbd
4-06211-2706
GCS - GECB
Reference List
Authorization Date D1: 2007-04-05
Running on PCB: GCA26800LC (GECB-EN)
Software Version: GAA30780DAA
Document Revision : V 1.0
Date SCN Author Comment
2007-04-05 GAA 307808 DAA A. Pfeffer Original Document
Copyright jjjj, OTIS GmbH & Co. OHG Berlin.
No part of this document may be copied or reproduced in any form or by any means without the prior written consent of
OTIS GmbH & Co OHG.
OTIS Software Basic Data No.:
G1530780AAAG21xxAAxx30
780DBAAB_REF
Engineering Center SCN:
Berlin GGCS - GECB G1530780AAAG2xxAAAA13x
x130780BDCAAB
Service Tool Reference List
Page: 2 /
21121211112116161
Date: 2005-072007U-04-
Revision History 05bd tbd
Date Rev Author Comment
4-06211-2706
2004-08-26 G1530780AAA A. Pfeffer first document based on TCBC Software
GAA30084AAF
2005-01-27 G2130780AAA H.-K. Spielbauer Number update only priorxshipping
2005-03-03 G2230780AAA A. Pfeffer conditions for EFO inputs added
2005-03-29 G2430780AAA A. Pfeffer blink messages "DOL alw. on", "No 110VAC",
"OmuPresent" added
Event "0307 RDOL alw.on" added
2005-04-06 GAA30780AAA A. Pfeffer Release
2005-07-21 GAA30780AAB A. Pfeffer HPB added for Compass
2005-10-25 GAA30780AAC A. Pfeffer no changes
2006-10-26 GAA30780BAA B. Braasch Op. Mode: CBP; EAR; added
Mo. State: SD->SR; renamed., ES; EF; EW;
RL; added
Mo.Command: Relevel; added
System inputs: GDS; L30; L50; GSM; DHB;
SDB; ^GSM; ^DHB; ^SDB; ADB; EDB;1EF;
2EF; DDS; DES; EQ1; EQ2; EQ3;
EQW;EQR; ISP; FAN; ^FAN; CTC; CTO;
PKG; CFB; IST; ROT; ACC; ACH; GSI; HCH;
GCO; CHC; GCB; ^GCB; LDS; MAS; HCR;
ATK; ^RB; GRT; DPC; UPC; DUP; SRO;
AD1; AD2; AD3; BPZ; ELZ; GFB; WCO;
SG1-SG7; CS1-CS6; CSC; CSK; GSK; CLR;
DFO; ^DFO; LEV; DCD; CCB; CCT; PC1-
PC8; SHC SHT; AMC; LPT; SMB; added
System outputs: UD; added
Blink message: MRO active; added
Event logging: 16; 17; 19; 109; 110; 213-
217; 224; 225; 308-315; 319; 505-507; 604;
605; added
2006-11-30 GAA30780BAA A. Pfeffer Event 235 added
2006-12-22 G1330780CAA B. Braasch Event 312;313;319 renamed, 320 added
2007-04-03 G1230780DAA H.-K. Spielbauer Update for DAA release
2007-04-05 GAA30780DAA A. Pfeffer Event 0606 added
OTIS Software Basic Data No.:
G1530780AAAG21xxAAxx30
780DBAAB_REF
Engineering Center SCN:
Berlin GGCS - GECB G1530780AAAG2xxAAAA13x
x130780BDCAAB
Service Tool Reference List
Page: 2 /
21121211112116161
Date: 2005-072007U-04-
05bd tbd
Table of Contents
4-06211-2706
1 Operational Modes.........................................................................4
2 Motion States..................................................................................5
x
3 System Inputs................................................................................6
4 System Outputs............................................................................10
5 Info Messages..............................................................................11
6 Blinking Event Messages............................................................12
7 Event Logging..............................................................................15
8 Diagnostic Parameters................................................................20
9 Commands...................................................................................21
OTIS Software Basic Data No.:
G1530780AAAG21xxAAxx30
780DBAAB_REF
Engineering Center SCN:
Berlin GGCS - GECB G1530780AAAG2xxAAAA13x
x130780BDCAAB
Service Tool Reference List
Page: 2 /
21121211112116161
Date: 2005-072007U-04-
05bd tbd
1 Operational Modes
4-06211-2706
Mode Description Remark
ACP Anti Crime Protection x
ANS Anti Nuisance Service
ARD Automatic Return Device
ATT ATTendend service
CBP Car Button Protection
CHC Cut off Hall Call
COR COrrection Run
CTL Car To Landing
DBF Drive / Break Fault
DCP Delayed Car Protection
DCS Door Check Sequence
DHB Door Hold Button mode
DLM Door Lock Monitoring
DTC Door Time protection Close
DTO Door Time protection Open
EFO Emergency Fireman's Operation
EFS Emergency Fireman's Service
EHS Emergency Hospital Service
EMT Emergency Medical Transport
EPC Emergency Power wait for Correction run
EPR Emergency Power Rescue run
EPW Emergency Power Wait for normal
EQO Earth Quake Operation
ESB Emergency Stop Button resp. J-Relay fault
GCB General Control of Buttons
HAD Hoistway Access Detection
HBP Hall Button Protection since AAB
IDL IDLe
INI INItialize
INS INSpection
ISC Independent ServiCe
LNS Load Non Stop service
MIT Moderate Incoming Traffic
NAV Not AVailable
NOR NORmal
OLD OverLoad Device
PKS ParKing Switch
PRK PaRKing
ROT car RiOT operation
SHO SHabat Operation
WCO Wild Car Operation
OTIS Software Basic Data No.:
G1530780AAAG21xxAAxx30
780DBAAB_REF
Engineering Center SCN:
Berlin GGCS - GECB G1530780AAAG2xxAAAA13x
x130780BDCAAB
Service Tool Reference List
Page: 2 /
21121211112116161
Date: 2005-072007U-04-
2 Motion States 05bd tbd
State Description Remark4-06211-2706
CR Correction Run
EF Emergency Fast run DRV-TYP=0
x
ES Emergency Stop DRV-TYP=0
EW Emergency during Wait DRV-TYP=0
FR Fast Run
ID IDle
IN INspection Run
NR Not Ready
RL Relevel DRV-TYP=1
RS ReScue Run
SR Slow Run
ST STop
OTIS Software Basic Data No.:
G1530780AAAG21xxAAxx30
780DBAAB_REF
Engineering Center SCN:
Berlin GGCS - GECB G1530780AAAG2xxAAAA13x
x130780BDCAAB
Service Tool Reference List
Page: 2 /
21121211112116161
Date: 2005-072007U-04-
05bd tbd
3 System Inputs
4-06211-2706
The following list shows all available inputs and the condition under which these inputs are
displayed (set DISP-ALL=1 to view all available inputs). x
input group Description is displayed when ...
ES Safety Chain Emergency Stop switch
DW door open contact
DFC Door Fully Closed contact
GDS Gate Door Switch
SE Start Enable Start Enable
1TH Thermal contact 1
2TH Thermal contact 2
TCI Inspection Top of Car Inspection switch
UIB Up Inspection Button
DIB Down Inspection Button
ERO Emergency Recall Operation switch
TDO Top of Car Door Open Button
TDC Top of Car Door Close Button
^TDO rear Top of Car Door Open Button
^TDC rear Top of Car Door Close Button
TCB Top of Car Inspection Button (TCIB)
DZ Doorzone Door Zone (LV1 and/or LV2)
1LV Door Zone switch 1LV
2LV Door Zone switch 2LV DZ-TYP0
1LS Limit Switches Limit Switch 1
2LS Limit Switch 2
BY Drive BY-Relay
BRK BR-Relay
LWO Load Weighing overload signal LWO
LWX load weighing bypass LWX
LNS Load Non Stop
L30 30% load in car LW-TYP = 2
L50 50% load in car LW-TYP = 2
DOL Front Door Door Open Limit switch
DCL Door Close Limit switch
DOB Door Open Button
DCB Door Close Button
EDP Electronic Door Protection
LRD Light Ray Device
DOS Door Open Signal
GSM Gate Switch Monitor
MDD Moving at front of Door Detection
DHB Door Hold Button
SDB Special Door Open Button
OTIS Software Basic Data No.:
G1530780AAAG21xxAAxx30
780DBAAB_REF
Engineering Center SCN:
Berlin GGCS - GECB G1530780AAAG2xxAAAA13x
x130780BDCAAB
Service Tool Reference List
Page: 2 /
21121211112116161
Date: 2005-072007U-04-
input group Description is displayed05bd
whentbd
...
^DOL Rear Door rear Door Open Limit switch
^DCL rear Door Close Limit switch
^DOB rear Door Open Button 4-06211-2706
^DCB rear Door Close Button
^EDP rear Electronic Door Protection
^LRD rear Light Ray Device x
^DOS rear Door Open Signal
^GSM rear Gate Switch Monitor
^MDD Moving at rear of Door Detection
^DHB rear Door Hold Button
^SDB rear Special Door Open Button
CCT Switches Car Call to Top
CCB Car Call to Bottom
CHC Cut off Hall Call
DDO Disable Door Operation
RTB Remote Tripping Button
RRB Remote Resetting Button
EFO Emergency Emergency Firemen Operation EFO-P<100
HTS Hall Temperature Sensor from SPB
AEF Alternative EFO (AEFO) EFO-P<100
EFK Emergency Fireman Key EFO-P<100
ASL Alternative Service Landing EFO-P<100
ESK Emergency Service Key switch EFO-P<100
ESH Emergency Service Hold switch EFO-P<100
CFS Car Fireman Service switch EFO-P<100
tralia)
CS Car fireman service Start switch EFO-P<100
XEF Overide EFO EFO-P<100
EFB Emergency Firemen Key Bypass EFO-P<100
(EFKB)
ADB Alternative Door Button
EDB EFO Door Button
1EF Taiwan Fireman Service Key switch 1
2EF Taiwan Fireman Service Key switch 2
DDS Disable Door Switch Relay
DES Disable EEC Relay
NU Emerg. Power emergency power operation signal EPO-P<100
NUD emergency power operation signal EPO-P<100
NUG emergency power operation signal EPO-P<100
NRF NURF EPO-P<100
EQ1 Earthquake Earthquake Contact Grade 1
EQ2 Earthquake Contact Grade 2
EQS Earth Quake Switch
EQW Earthquake Counterweight Switch
EQR Earthquake Reset Switch
ISS OCSS Independent Service Switch
^ISS rear Independent Service Switch
ISP Independent Service Parking switch
PDD Partition Door Device switch
OTIS Software Basic Data No.:
G1530780AAAG21xxAAxx30
780DBAAB_REF
Engineering Center SCN:
Berlin GGCS - GECB G1530780AAAG2xxAAAA13x
x130780BDCAAB
Service Tool Reference List
Page: 2 /
21121211112116161
Date: 2005-072007U-04-
input group Description is displayed05bd
whentbd
...
FAN Fan
^FAN rear Fan
HFA Handicapped COP Fan 4-06211-2706
CTL Car To Lobby CTL-P<100
CTC CTLPC Car To Landing Park with
doors Closed switch x
CTO CTLPO Car To Landing Park with
doors Open switch
PKS ParKing Switch PKS-P<100
PKG PKS Group switch
CFB RSL Car FeedBack
IST Intermittent Stop switch
ROT Riot OperaTion
ACC Anti Crime Car switch
ACH Anti Crime Hall switch
GSI Group Successive Starting In
COC Cut/Disable Car-call cut Off (Car)
COH Car-call cut Off (Hall)
HCO Hall-call Cut Off
HCH Hall Call Cut off from Car
GCO hall call Cut Off (Group)
CHC Cut Hall Call switch latch
DFD Disable Front Door
DRD Disable Rear Door
GCB General Control Button
^GCB Rear General Control Button
CRC Card Reader Contact EN-CRO0
BOS BOSs card reader overwrite EN-CRO0
LDS Lobby Door Open Switch
MAS Maintenance Access Switch
HCR Hall Call Card Reader
ATK Attendant Attendant Key switch
ATU Attendant key Up
ATD Attendant key Down
NSB Non Stop Button
RB Reset Button
^RB rear Reset Button
GRT Group Group Riot
DPC Down Peak Clock
UPC Up Peak Clock
DUP Dual Up Peak Clock
SRO Separate Riser Operation Switch
AD1 Alternate Dispatch floor key switch 1
AD2 Alternate Dispatch floor key switch 2
AD3 Alternate Dispatch floor key switch 3
BPZ Parking Zone
ELZ Parking Zone
GFB Group link Feedback input
WCO Wild Car Operation switch
SG1 Split Group operation key switch 1
SG2 Split Group operation key switch 2
SG3 Split Group operation key switch 3
OTIS Software Basic Data No.:
G1530780AAAG21xxAAxx30
780DBAAB_REF
Engineering Center SCN:
Berlin GGCS - GECB G1530780AAAG2xxAAAA13x
x130780BDCAAB
Service Tool Reference List
Page: 2 /
21121211112116161
Date: 2005-072007U-04-
input group Description is displayed05bd
whentbd
...
SG4 Split Group operation key switch 4
SG5 Split Group operation key switch 5
SG6 Split Group operation key switch 6 4-06211-2706
SG7 Split Group operation key switch 7
CS1 Secure Access Car Secure access button 1 x
CS2 Car Secure access button 2
CS3 Car Secure access button 3
CS4 Car Secure access button 4
CS5 Car Secure access button 5
CS6 Car Secure access button 6
CSC Car Secure access Clear switch
CSK Car Secure access Keyswitch
GSK Group Secure access Keyswitch
CLR REM Car Light Relay
DFO Door Fully Opened
^DFO Rear Door Fully Opened
LEV Level Signal for REM
DCD Russian Code Disable Call and Door switch
CCB Car Call to Bottom landing
CCT Car Call to Top landing
PC1 Simplex Park Car Clock 1
PC2 Park Car Clock 2
PC3 Park Car Clock 3
PC4 Park Car Clock 4
PC5 Park Car Clock 5
PC6 Park Car Clock 6
PC7 Park Car Clock 7
PC8 Park Car Clock 8
SHC Shabbat Shabat Operation Switch
SHT Shabat Operation Timer
AMC Miscellanious AM Clock input
LPT Landing Passing Tone
SMB Speech Message Board Busy
OTIS Software Basic Data No.:
G1530780AAAG21xxAAxx30
780DBAAB_REF
Engineering Center SCN:
Berlin GGCS - GECB G1530780AAAG2xxAAAA13x
x130780BDCAAB
Service Tool Reference List
Page: 2 /
21121211112116161
Date: 2005-072007U-04-
05bd tbd
4 System Outputs
4-06211-2706
output group Description is displayed when ...
1RT Tripping Remote Tripping for car x
1RR Remote Resetting for car
3RT Remote Tripping for counterweigt
LVC Door Bypass LVC-Relay
SFR Safe To Relevel (door bypass active and
no demand to run)
DFR OCSS DFC-Relay
PDR Power Down Relay (Power Save Mode)
LR Light Relay
UD Up / Down (e.g. trip counter) Depends on parameter PX2.1
NUD Emergency
NUG
BUT REM BUTton operated (any demand to move)
DO Door fully Opened
NORM NORMal operation (no faults)
CPR Car PaRked, waiting for demand
MF Main Floor (lobby)
LND LaNDing passing
OOS Out Of Service
LEV LEVel signal
DC Door Close Command
RFS Request For Service
SPB Service Panel Board Fault
SCS Slack Belt Contact Switch
HTS Hall Temperature Sensor on SPB
RDO Rear Door Open Signal
RDC Rear Door Close Signal
BRK Brake Signal from Drive
SAF Safety Chain (ES)
DS Door Switch (with DBP: DW, w/o DBP:
DFC)
CLM Car Light Monitoring
DOP Door Open Sensor
^ROP Rear Door Open Sensor
OTIS Software Basic Data No.:
G1530780AAAG21xxAAxx30
780DBAAB_REF
Engineering Center SCN:
Berlin GGCS - GECB G1530780AAAG2xxAAAA13x
x130780BDCAAB
Service Tool Reference List
Page: 2 /
21121211112116161
Date: 2005-072007U-04-
05bd tbd
5 Info Messages
4-06211-2706
The following messages are accessible in the Main Menu GECB – Menu.
Please use Shift Key UP. x
Info Message Comment
OVF-WW CAN-Comm Controller Type and Drive Type
Operat: FCL > used Operation Mode
DCL > (parameter OPERAT, EN-BSM)
SAPB-IL >
SAPB-CC >
FCL-UD >
FCL-SB >
DCL+BSM>
DBP : yes > Door Bypass enabled?
no > (ADO or RLV enabled: parameter EN-ADO, EN-RLV)
# RSL's: 1 > Number of RSL links. "3" is displayed if the GECB-IO board
3 > physically supports 3 links and the parameter RSL-TYP=1
is set. Otherwise "1" is displayed.
OTIS Software Basic Data No.:
G1530780AAAG21xxAAxx30
780DBAAB_REF
Engineering Center SCN:
Berlin GGCS - GECB G1530780AAAG2xxAAAA13x
x130780BDCAAB
Service Tool Reference List
Page: 2 /
21121211112116161
Date: 2005-072007U-04-
05bd tbd
6 Blinking Event Messages
4-06211-2706
The following messages are blinking in each status display of the Service Tool:
x
Blink-Mes- Description related
sage setup
wrongBoard The software cannot identify the board.
replace the GECB.
SCN Error Wrong Software
order a new software with correct partnumber (refer
to Baseline Release Document).
Learn Run a) The drive package is performing its Learn Run to DRV-TYP=0
learn the hoistway situation.
b) The drive package is adjusting the encoder.
wait until the learn run has completed.
DoorBridge DW or DFC input has not been low while the door was
opened. Reason is a bridged door lock.
check safety chain
This event is stored into EEPROM so that the ONLY
way to bring the elevator into operation again is by
using INS.
Switch INS Landing door was opened for longer than 2 seconds or
the car door is bridged. Elevator is taken out of service.
This event is stored into EEPROM so that the ONLY
way to bring the elevator into operation again is by us-
ing INS.
TCI-lock The sequence to leave TCI-mode was not correctly fol-
lowed:
1. open door
2. switch TCI off
3. close door
No 110VAC! The power supply of the safety chain is missing.
Check connection.
Check fuses.
1LS+2LS on Limit switches 1LS and 2LS are active (low) at the same
time.
Check power supply of the position reference sys-
tem.
Adr-Check Some RSL I/Os have to be programmed to a valid ad- TCI(691)
dress and are not allowed to be set to 00-0 or 01-0. Cur-
rently only one I/O is checked:
691 – TCI
Set I/O 691 to a valid address
DOL alw.on The signal DOL RDOL is low while the door is closed. DOL (000)
OTIS Software Basic Data No.:
G1530780AAAG21xxAAxx30
780DBAAB_REF
Engineering Center SCN:
Berlin GGCS - GECB G1530780AAAG2xxAAAA13x
x130780BDCAAB
Service Tool Reference List
Page: 2 /
21121211112116161
Date: 2005-072007U-04-
Blink-Mes- Description related
05bd tbd
sage setup
Check Event log to find out whether the front or the4-06211-2706
RDOL(544)
rear door signal is wrong.
Check door fuses.
Check 24V power supply x
SE-Fault The car cannot start due to missing SE-signal
Check the door bypass
1TH-Fault The DBR-contact which is connected to the input 1TH is
opened. The drive is powered down to allow cooling.
2TH-Fault One of the contacts which is connected to the 2TH is
opened.
PowerSave The drive package is currently switched off to save en- PDR-D
ergy.
start DCS! a) Normal operation is not allowed until the Door Check
Sequence has been completed successfully.
b) The DCS is required again if one of the parameters
TOP or BOTTOM is changed.
Enter M-1-3-5 to start the DCS!
Shutdown The drive reports a Shutdown or CAN-Communication
not working
See event logging of MCB.
check CAN-wiring
check CAN-LEDs
Car Light Car Light Relay on top of car is dropped. CLR (1000)
Note:
This message has been renamed in AAE.
LBG/CSP-2 Light Beam Gate has been active. LBG
(967, 968)
SPB: HTS Hall Temperature Sensor from Service Panel Board is SPB-Temp
activated. Car is shutdown at next committable floor and
taken out of service until the temperature is lower than
parameter SPB-Temp.
SPB-Comm. CAN-Communication to SPB is not working.
check CAN-wiring
check CAN-LEDs
MRO active The SPB requests to ignore the inputs at Manual Res-
cue Run.
OmuPresent A wrong procedure was used to plug the OMU. TCI (691)
It must be ensured that TCI is switched OFF while the
controller is powered down:
While the controller is on, switch TCI off (NOR or
ERO)
switch the controller off
OTIS Software Basic Data No.:
G1530780AAAG21xxAAxx30
780DBAAB_REF
Engineering Center SCN:
Berlin GGCS - GECB G1530780AAAG2xxAAAA13x
x130780BDCAAB
Service Tool Reference List
Page: 2 /
21121211112116161
Date: 2005-072007U-04-
Blink-Mes- Description related
05bd tbd
sage setup
switch the controller on 4-06211-2706
x
OTIS Software Basic Data No.:
G1530780AAAG21xxAAxx30
780DBAAB_REF
Engineering Center SCN:
Berlin GGCS - GECB G1530780AAAG2xxAAAA13x
x130780BDCAAB
Service Tool Reference List
Page: 2 /
21121211112116161
Date: 2005-072007U-04-
05bd tbd
7 Event Logging
4-06211-2706
The table below lists all possible event logging messages of the Service Tool. The events
are devided into the following classes: x
I Info
W Warning
F Fault
event class reason related setup
total runs total number of runs since last power on -
minutes on minutes since last power on -
Operating System
0000 Task Timing W Dummy task has not been called within -
timeout. Software has been restarted.
0001 S/W Reset W watchdog circuit on GECB was triggered. -
Software has been restarted.
0002 Illegal Int W illegal interupt was executed -
0003 CanTxFull W CAN messages cannot be sent -
0004 CanBusOff W CAN communication has been restarted -
0006 StackCheck F Stack Violation was detected. Software -
has been restarted.
0007 SCN Error F Wrong Software. -
order a new software with correct part-
number.
0008 TimerSync F Internal software timers have not been -
updated correctly. Software has been
restarted.
0009 Task Fail F Application software doesn't run properly. -
Software has been restarted.
0010 McbCommErr F No CAN connection to the drive -
0011 SpbCommErr W No CAN connection to the SPB -
0012 Power On I Board has been powered on. -
0013 Event Fail W -
0014 PowerOffOn I Short Failure of PowerSupply. -
0016 S/W Restart W Reset with unknown reason -
0017 Trace Error F bad value in the eventTraceControl buffer -
0019 MissedLvInt F lv1 and lv2 edge was missed -
Operational Control Sub System
0100 OpMode NAV F OCSS is not available due to drive fault -
(e.g. drive-fault (NR). This mode is also
active after INS before the COR starts
OTIS Software Basic Data No.:
G1530780AAAG21xxAAxx30
780DBAAB_REF
Engineering Center SCN:
Berlin GGCS - GECB G1530780AAAG2xxAAAA13x
x130780BDCAAB
Service Tool Reference List
Page: 2 /
21121211112116161
Date: 2005-072007U-04-
event class reason related
05bd tbd setup
0101 EPO shutd. W The car is not able to run during EPO (e.g. NU (017)
because it is switched to ERO); the next 4-06211-2706
NUSD (018)
car is allowed to recover. NUSG (019)
0102 OpMode DTC W door was not able to close (missing DCL, DCL (694)
DFC or DW) within timeout x RDCL (695)
DOOR, REAR
DTC-T
0103 OpMode DTO F door was not able to open (missing DOL) DOL (000)
within timeout RDOL (544)
DOOR, REAR
DTO-T
0104 OpMode DCP W car was not able to answer a call within DCP-T
timeout (e.g. door was held open manu-
ally)
0106 PDS active I partition door switch is opened PDD (784)
0107 DS bypass F Malfunction of Disable Door Switch Relays DDSRC (970)
(DDSR) for Generic Firemen Service.
0108 EEC bypass F Malfunction of Disable Emergency Exit DEMERC (971)
Contact Relay (DEMERC) for Generic
Firemen Service.
0109 Stuck DCB F Door Close Button contact permanent ac- DCB (003)
tive
0110 Stuck RDCB F Rear Door Close Button contact perma- RDCB (547)
nent active
Motion Control Sub System
0201 Correct.Run I A correction run was performed (e.g. after -
INS, NAV)
0202 /ES in FR W ES-input was activated during Fast Run -
0203 /ES in SR W ES-input was activated during Slow Run -
0204 TCI/ERO on I TCI or ERO has been switched on ERO-TYP
0205 SE-Fault F The car cannot start due to missing SE- -
signal
Check the door bypass
0210 /DZ in NST F DZ-signal was lost or not detected at all af- DZ-TYP
ter having stopped
0211 /DFC in FR W car door has been opened during Fast -
Run
0212 /DFC in SR W car door has been opened during Slow -
Run
0213 DrvPrepErr W PrepareToRun expected from Drive -
(e.g. missing loadweighing information for
ABL)
0214 DrvStuckPtr W Drive stuck in PrepareToRun -
OTIS Software Basic Data No.:
G1530780AAAG21xxAAxx30
780DBAAB_REF
Engineering Center SCN:
Berlin GGCS - GECB G1530780AAAG2xxAAAA13x
x130780BDCAAB
Service Tool Reference List
Page: 2 /
21121211112116161
Date: 2005-072007U-04-
event class reason related
05bd tbd setup
0215 DrvStuckRtr W Drive stuck in ReadyToRun(NoAbl) -
0216 DrvBrakeErr F Brake not lifted. -
4-06211-2706
0217 DrvCreepErr F Drive Creeptime too long. -
0218 DrvShutdown F The drive reports a Shutdown -
See event logging of MCB. x
0219 DrvStartErr F
0220 DrvService W The drive requested “Request For Service” -
(REM). See drive event logging for reason.
0222 1TH-Fault W The DBR-contact which is connected to -
the input 1TH is opened. The drive is pow-
ered down to allow cooling.
0223 2TH-Fault F One of the contacts which is connected to -
the 2TH is opened.
0224 DrvEndRun F Drive did not end the run. -
0225 110VAC dead F 110VAC is dead for 5 seconds -
0228 1LS+2LS on F Limit switches 1LS and 2LS are active at -
the same time.
Check power supply of the position ref-
erence system.
0230 RSL Adr Chk F Some RSL I/Os have to be programmed to TCI(691)
a valid address and are not allowed to be
set to 00-0 or 01-0. Currently only one I/O
is checked:
691 – TCI
Set I/O 691 to a valid address
0233 PowerSave I The drive package has been powered on PDR-D
0235 ABL Abort W Advanced Brake Lift was aborted because EN-ABL=1,
the door was not fully closed 10 seconds DRV-TYP=1
after the brake was lifted.
0237 /DW in FR W landing door has been opened during -
Fast Run
0238 /DW in SR W landing door has been opened during -
Slow Run
Door Control Sub System
0300 DBP: dfc_SE F While the door was opening or fully EN-RLV,
opened, the door bypass was found to be EN-ADO
inactive (DFC low or SE high)
0301 DCL in [ ] F (R)DCL was active while the door was fully DCL (694)
opened RDCL (695)
0302 DoorBridge F DW or DFC was not low during the last -
door cycle, that means that the safety
chain is bridged or the Door Bypass is de-
fect.
OTIS Software Basic Data No.:
G1530780AAAG21xxAAxx30
780DBAAB_REF
Engineering Center SCN:
Berlin GGCS - GECB G1530780AAAG2xxAAAA13x
x130780BDCAAB
Service Tool Reference List
Page: 2 /
21121211112116161
Date: 2005-072007U-04-
event class reason related
05bd tbd setup
0304 DOL:alw. on F DOL was active while the door was fully DOL (000)
closed. This event is also logged when the4-06211-2706
fuses of the door system are burned.
This event is not logged within the first 40 x
seconds after system startup.
0306 Hwy Access F Landing Door was opened or the car door -
is bridged.
see description for blinking message
'Switch INS'
0307 RDOL:alw.on F RDOL was active while the door was fully RDOL (544)
closed. This event is also logged when the
fuses of the door system are burned.
This event is not logged within the first 40
seconds after system startup.
0308 DOOR sync F Multidrop synchronization error -
0309 DOOR adr. F Multidrop unused message origin -
0310 FDOOR chk F Multidrop front door checksum error -
0311 RDOOR chk F Multidrop rear door checksum error -
0312 FDOOR Tout F Multidrop front door communication time- -
out (>200ms)
0313 RDOOR Tout F Multidrop rear door communication timeout -
(>200ms)
0314 GDS noPull F GDS relay not pulled -
0315 GDS noDrop F GDS relay not dropped -
0319 GSM Ferror F GSM input error Front door -
0320 GSM Rerror F GSM input error Rear door -
Signaling Sub System
0400 RSL parity W Two remote stations with the same ad- -
dress are connected to the same link
0401 RSL sync W Synchronisation lost on remote serial link. -
Check whether there is a shortcut on
the link.
0402 RSL reinit F RSL driver has reported a problem. RSL -
was reinitialized.
0403 RSL Fail F Application has detected that the RSL -
driver doesn't run anymore. Software has
been restarted.
0404 RSL Hrtbeat F RSL driver has detected that the applica- -
tion doesn't run anymore. Software has
been restarted.
0405 RSL Board F RSL board mismatch! -
OTIS Software Basic Data No.:
G1530780AAAG21xxAAxx30
780DBAAB_REF
Engineering Center SCN:
Berlin GGCS - GECB G1530780AAAG2xxAAAA13x
x130780BDCAAB
Service Tool Reference List
Page: 2 /
21121211112116161
Date: 2005-072007U-04-
event class reason related
05bd tbd setup
0406 Group RSL F Group RSL has failed -
4-06211-2706
Group
0500 RNG1 msg W data error on Duplex/Triplex ring -
0501 RNG1 time W no ring messages received from other car x GROUP
for a specific time
0502 RNG1 sio W framing error on Duplex/Triplex ring -
0503 RNG1 tx W ring messages couldn't be sent in an ap- -
propriate time
0504 RNG1 rxOff W No messages are received within a time- -
out, and NO BREAK is detected.
0505 RNG1 reset W Reinitializing RING Service (stm_ring_run -
expired)
0506 DES offline F DES is not present -
0507 GCB offline F no GCB is present -
System
0600 SPB-Alert W The Service Panel Board detected a mal- -
function which hinders a manual rescue
operation with SPB and SDI. Possible rea-
sons are:
- defective speed encoders for SDI
- defective E2PROM on SPB
- Missing battery for SPB
Press the SPB-buttons REB + DDO simul-
taneously to locate the error.
0601 SPB:TempHTS W The Service Panel Board detected an SPB-Temp
overtemperature.
0602 LwssService W The LWSS requested “Request For Ser- -
vice” (REM). See LWSS event logging for
reason.
0604 S/W Changed I SCN changed -
0605 Update S/W! F NumEventGroups, eventGroup or event -
outside range
0606 SpbService W The SPB requested “Request For Service” -
(REM). See SPB event logging for reason.
OTIS Software Basic Data No.:
G1530780AAAG21xxAAxx30
780DBAAB_REF
Engineering Center SCN:
Berlin GGCS - GECB G1530780AAAG2xxAAAA13x
x130780BDCAAB
Service Tool Reference List
Page: 2 /
21121211112116161
Date: 2005-072007U-04-
05bd tbd
8 Diagnostic Parameters
4-06211-2706
These diagnosis parameters are stored in non-volatile memory and are kept even if the
power is switched off. They can only be reset manually via Service Tool,
x except ACT-T and
REC-OK which are refreshed after each power-on.
Parameter Meaning since
01 ACT-T Actual elapsed time since last power-on
02 TOT-T Total elapsed time
03 UP-CNT Up flight count
04 DN-CNT Down flight count
05 UP-RLV Up Relevel Count
06 DN-RLV Down Relevel Count
07 FD-CNT Front door openings count (reversals not considered)
08 RD-CNT Rear door openings count (reversals not considered)
09 DZ-CNT Door zone count
10 W_DOG-R. Watch-dog reset count (warm starts)
11 POW-ON Power-on count (cold starts)
12 REC-OK Recovery of previous stored diagnosis
OTIS Software Basic Data No.:
G1530780AAAG21xxAAxx30
780DBAAB_REF
Engineering Center SCN:
Berlin GGCS - GECB G1530780AAAG2xxAAAA13x
x130780BDCAAB
Service Tool Reference List
Page: 2 /
21121211112116161
Date: 2005-072007U-04-
05bd tbd
9 Commands
4-06211-2706
These internal commands are used for the on-board DCSS and MCSS.
Type Display Description
x
Door Commands OPEN open door
DEEN deenergize door
CLD1 close door; no DOB, no LRD, no EDP
CLD2 close door; full DOB, full LRD, full EDP
CLD3 close door; full DOB, full LRD, lim EDP
CLD4 close door; full DOB, lim LRD, lim EDP
CLD5 close door; full DOB, no LRD, no EDP
CLD6 close door; full DOB, no LRD, lim EDP
CLD7 close door; lim DOB, no LRD, lim EDP
CLD8 close door; lim DOB, no LRD, no EDP
CLD9 close door; full SGS, nothing else
DCSS-5 Commands Ded&Eds 000 - Deenergize; Emergency Door Stop
Ded 001 - Deenergize
Cld&Dob 010 - Close Door; DOB, LRD, PP enabled
Cld 011 - Close Door; no reversal allowed
Ndg 100 - Nudging
Cld&Rev 101 - Close Door; LRD, PP enabled
Opn 111 - Open Door
Motion Commands CarGoTo Go to specific floor
ESMGoTo Emergency Service
Stand By Standby or Inspection
ReInit reinit position
ImmStop Immediate Stop
Relevel Relevel
Nxt Flor Go to next reachable floor