Elmeasure Automatic Power Factor Controller Catalog

This document summarizes the features and specifications of an APFC Power Factor Controller. The controller monitors current, voltage, frequency, power factor, VAR and controls power factor through 6/8/12 stage relay outputs. Key features include true RMS measurements, automatic calculation of connection type and C/k ratio, high/low parameter storage, and RS485 communication. The controller aims to maintain power factor within a required range through intelligent switching of capacitor banks.

Uploaded by

SEO BDM
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
668 views1 page

Elmeasure Automatic Power Factor Controller Catalog

This document summarizes the features and specifications of an APFC Power Factor Controller. The controller monitors current, voltage, frequency, power factor, VAR and controls power factor through 6/8/12 stage relay outputs. Key features include true RMS measurements, automatic calculation of connection type and C/k ratio, high/low parameter storage, and RS485 communication. The controller aims to maintain power factor within a required range through intelligent switching of capacitor banks.

Uploaded by

SEO BDM
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

APFC

POWER FACTOR
CONTROLLER
Current | Voltage | Frequency | PF | VAR | 6/8/12 stage control

INTELLIGENT DEVICE TO MAINTAIN THE POWER


FACTOR IN REQUIRED RANGE!

Features: Technical Specification:


True RMS Measurements Specification Description

Simultaneous sampling of voltage and current Accuracy: Class 1: IEC 62053-21 (Default),
Auto Learn of connection type Class 0.5: IEC 62053-22 (Optional)

Automatic calculation of C/k ratio Update Rate: 1 sec


High and Low of V, A, PF for last one minute through communication Power system Programmable: Star (3Phase 4Wire), Delta (3Phase 3Wire),
Accuracy class: class 1.0 as per standard IEC 62053-21 type: 3U. 1A ( 3 voltages, 1current)

3Phase measurement Sensing/Measurement: True RMS, 1 Sec update time. 2 Quadrant Power & Energy.

4/6/8/10 (APFC640) 10/12/16 (APFC440) switching relay outputs Input voltage 4 Voltage inputs (V1, V2, V3, VN) Programmable 110 or
(Measurement) 415V LL. Nominal Primary Programmable up to 999 kV.
Auto recognition of the CT phase
Burden: 0.2VA Max. per phase
Two quadrant operations
External Fuse Rating: 3 Amps
21 pre-programmed control series of capacitor values required for
Input Frequency: 45 Hz - 65Hz
the compensation network
Input Current Current inputs (A1, A2, A3) 5mA - 6A (Field configurable
Learns the number of capacitors connected and the value ( 10% load)
(Measurement): 1A or 5A) . Primary Programmable up to 99 kA
Capacitance-based power factor correction takes care of variation in
Overload: 10A max continuous, 50A max for 3 Sec
voltage and frequency
Burden: 0.2VA Max. per phase
Stores the number of switching and On hours of each capacitor
Auxiliary Supply 180 to 300V AC/DC, 40-70Hz
Displays Basic, Power, Energy and THD parameters (Control Power): Burden: 10VA Max
Built-in Alarms: Alarm/Fault detection, Overcompensation, Under External Fuse Rating: 200mA Slow blow type
compensation, Over voltage, Over current, Under voltage, Under
CT PT Ratio Max.: 2000 MVA Programmable
current, Reverse Amps, Over harmonics voltage and current
Protection Class: 3
Measurement Category: CAT lll ( As per IEC 61010)
Control Features
Humidity: 5% to 95% non-condensing
Intelligent Power Factor Controlling based on the capacitor bank Pollution Degree: 2 (As per IEC 61010)
switching's history (Number of operations, ON Time) which improves
the capacitor life time Altitude: Below 2000m

Optional communication of present kVAR value based on voltage and Insulation: Double Insulation ( As per IEC 61010-1)
frequency Ingress Protection: IP 51 ( front facia)
Controlling based on VAR parameter
Operating Temperature: -10°C to + 55°C (14°F - 131°F)
Control principle – nearest value first
Storage Temperature: -25°C to +70°C (-13°F - 158°F)
Minimum sensing current for controlling operation 50mA (1% load)
Wire Gauge 26 - 10AWG (4.0mm2).
RS485 communication (optional)
(Connecting wires):
On Site Programmable:
- Alarm display Container material: PC
- Selectable stages Display: Type: Customised 3 row 4 digit LED with % Level indicator.
- Alarm levels based on the comfort level of the user Dimension: 3Row 4Digit 0.56” (14mm) Red.
- Password protection Resolution: 4 digits for instantaneous parameters, 8 digits
- CT ratio suitable for any load for integrated parameters.
- Star/Delta/3phases or 1 CT option programmable LED Bar Graph: % Load indication with programmable
Disables the capacitor automatically when the capacitor is deteriorated parameters (A, VA, WATT)
beyond a certain level Communication: Rs485 serial channel connection Industry standard
Improved sensing of switch ON / OFF capacitor within the programmed Modbus. RTU protocol. 2000 volts AC isolation for 1 minute
level and not towards UPF between communication and other circuits.
Improved Switching's ON / OFF methodology to operate the system Baud rate: 4800, 9600, 19.20K, 38.40K (Preferred 9600 bps).
very close to the target power factor Isolation: 2000 volts AC isolation for 1 minute between
Improved life cycle of the capacitor with less count of switching communication and other circuits.
Parity: Even, Odd, No
Improved power factor calculation based on reference Voltage and
Device/Meter ID: 1 to 247 (Programmable)
Frequency
Improved method of Capacitor switching when the alarm occurred Relay contact rating: SPST, 3A@240VAC
Threshold setting Lag to Lag or Lag to Lead Mechanical Spec.: APFC440 (144 x 144mm) Panel cutout: 138 x 138mm
(Panel Mount) APFC640 (96 x 96mm) Panel cutout: 90 x 90mm
Applications: Weight: APFC440: 700gms
APFC640: 400gms
Manufacturing industries, Chemical industry, Cement plant, Sugar plant,
Textile, Hospitals, Automobile industry, etc. Note: Additional error of 0.1% of full scale, for meter input current below 500mA