General information
Legal information
The contents of this document are provided “as is”. Except as required by applicable law,
no warranties of any kind, either express or implied, including, but not limited to, the
implied warranties of merchantability and fitness for a particular purpose, are made in
relation to the accuracy and reliability or contents of this document. Westermo reserves
the right to revise this document or withdraw it at any time without prior notice.
Under no circumstances shall Westermo be responsible for any loss of data or income or
any special, incidental, and consequential or indirect damages howsoever caused.
More information about Westermo can be found at www.westermo.com
About This Guide
This guide is intended for installation engineers and users of the Westermo products.
It includes information on safety and regulations, a product description, installation
instructions and technical specifications.
6644-2214                                                                                3
Safety and Regulations
Warning signs are provided to prevent personal injuries and/or damages to the product.
The following levels are used:
    Level of warning    Description               Consequence          Consequence
                                                  personal injury      material damage
                        Indicates a potentially   Possible death or    Major damage to the
                        hazardous situation       major injury         product
        WARNING
                        Indicates a potentially   Minor or moderate    Moderate damage to
                        hazardous situation       injury               the product
        CAUTION
                        Provides information      No personal injury   Minor damage to the
                        in order to avoid                              product
                        misuse of the
                        product, confusion or
                        misunderstanding
         NOTICE
                        Used for highlighting     No personal injury   Minor damage to the
                        general, but important                         product
                        information
          NOTE
4                                                                                  6644-2214
Safety Information
Before installation:
Read this manual completely and gather all information on the product. Make sure that
you understand it fully. Check that your application does not exceed the safe operating
specifications for this product.
                  WARNING - SAFETY DURING INSTALLATION
                  The product must be installed and operated by qualified service
                  personnel and installed into an apparatus cabinet or similar, where
                  access is restricted to service personnel only.
                  During installation, ensure a protective earthing conductor is
                  first connected to the protective earthing terminal (only valid for
                  metallic housings). Westermo recommends a crosssectional area
                  of at least 4 mm2.
                  If the product does not have a protective earthing terminal,
                  then the DIN-rail must be connected to protective earth. Upon
                  removal of the product, ensure that the protective earthing
                  conductor, or the connection to earth via the DIN-rail, is
                  disconnected last.
                  WARNING - HAZARDOUS VOLTAGE
                  Do not open an energized product. Hazardous voltage may occur
                  when connected to a power supply.
                  WARNING - PROTECTIVE FUSE
                  The power supply wiring must be sufficiently fused. It must be
                  possible to disconnect manually from the power supply. Ensure
                  compliance to national installation regulations.
                   eplacing the internal fuse must only be performed by Westermo
                  R
                  qualified personell.
6644-2214                                                                                 5
    WARNING - REDUCE THE RISK OF FIRE
    To reduce the risk of fire, use only telecommunication line cords
    with a cable diameter of AWG 26 or larger. Regarding power
    cable dimensions, see Interface Specifications.
    CAUTION - CLASS 1 LASER PRODUCT
    Do not look directly info a fibre optical port or any connected
    fibre, although the product is designed to meed the Class 1 Laser
    regulations and complies with 21 CFR 1040.10 and 1040.11.
    CAUTION - FIBRE OPTIC HANDLING
    Fibre optic equipment need special treatment. It is very sensitive
    to dust and dirt. If the fibre is disconnected from the product, the
    protective plugs on the transmitter/receiver must be connected.
    The protective plugs must be kept on during transportation. The
    fibre optics cables must be handled the same way.
    CAUTION - CORROSIVE GASES
    If the product is placed in a corrosive environment, it is important
    that all unused connector sockets are protected with a suitable
    plug, in order to avoid corrosion attacks on the gold plated
    connector pins.
    CAUTION - ELECTROSTATIC DISCHARGE (ESD)
    Prevent electrostatic discharge damages to internal electronic
    parts by discharging your body to a grounding point (e.g. use a
    wrist strap).
6                                                                   6644-2214
Care recommendations
Follow the care recommendations below to maintain full operation of product and to
fulfil the warranty obligations:
• Do not drop, knock or shake the product. Rough handling above the specification may
cause damage to internal circuit boards.
• Use a dry or slightly water-damp cloth to clean the product. Do not use harsh
chemicals, cleaning solvents or strong detergents.
• Do not paint the product. Paint can clog the product and prevent proper operation.
If the product is used in a manner not according to specification, the protection provided
by the equipment may be impaired.
If the product is not working properly, contact the place of purchase, nearest Westermo
distributor office or Westermo technical support.
Cleaning of the optical connectors
In the event of contamination, the optical connectors should be cleaned by the use of
forced nitrogen and some kind of cleaning stick.
Recommended cleaning fluids:
• Methyl-, ethyl-, isopropyl- or isobutyl-alcohol
• Hexane
• Naphtha
Product disposal
                            This symbol means that the product shall not be treated
                            as unsorted municipal waste when disposing of it. It needs
                            to be handed over to an applicable collection point for
                            recycling electrical and electronic equipment.
                            By ensuring the product is disposed of correctly, you will
                            help to reduce hazardous substances and prevent potential
                            negative consequences to both environment and human
                            health, which could be caused by inappropriate disposal.
6644-2214                                                                                7
Article number, model and description
    Article        Model                        Description
    3644-0001      SDW-550                      10/100Base-T/TX: 5 ports
    3644-6001      SDW-550 E-mark               10/100Base-T/TX: 5 ports
    3644-0020      SDW-541-MM-SC2               10/100Base-T/TX: 4 ports 100Base-FX: 1 port
    3644-0022      SDW-541-SM-LC15              10/100Base-T/TX: 4 ports 100Base-FX: 1 port
    3644-0023      SDW-541-MM-LC2               10/100Base-T/TX: 4 ports 100Base-FX: 1 port
    3644-0024      SDW-541-SM-SC15              10/100Base-T/TX: 4 ports 100Base-FX: 1 port
    3644-0030      SDW-532-MM-SC2               10/100Base-T/TX: 3 ports 100Base-FX: 2 port
    3644-0032      SDW-532-SM-LC15              10/100Base-T/TX: 3 ports 100Base-FX: 2 port
    3644-0033      SDW-532-MM-LC2               10/100Base-T/TX: 3 ports 100Base-FX: 2 port
    3644-0034      SDW-532-SM-SC15              10/100Base-T/TX: 3 ports 100Base-FX: 2 port
    3644-0035      SDW-532-SM-LC40              10/100Base-T/TX: 3 ports 100Base-FX: 2 port
Simplified EU declaration of conformity
Hereby, Westermo declares that the equipment is in compliance with EU directives.
The full EU declaration of conformity and other detailed information are available at the
respective product page at www.westermo.com.
8                                                                                 6644-2214
Agency approvals and standards compliance
Type           Approval / Compliance
EMC            EN 61000-6-2, Immproducty industrial environments
               EN 61000-6-31, Emission residential environments
               EN 61000-6-42, Emission industrial environments
               E-Mark, Road Vehicles, 10R-04 72163
Safety         UL 60950-1, IT Equipment
Marine         DNV GL rules for classification – Ships and offshore products4
Note           1   _ Applicable only for 3644-x001
               2 _ Applicable only for 3644-0019,     3644-002x and 3644-003x
               3_ Applicable only for 3644-6001
               4   – Applicable only for 3644-0001, 3644-0022 , 3644-0023, 3644-0025,
                     3644-0032, 3644-0033, 3644-0035
Corrosive           This product has been successfully tested in a corrosion test according to
                    IEC 60068-2-60, method 3. This means that the product meets the requirements
environment:        to be placed in an environment classified as ISA-S71.04 class G3.
               CAUTION - CORROSIVE GASES
               If the product is placed in a corrosive environment, it is important
               that all unused connector sockets are protected with a suitable
               plug, in order to avoid corrosion attacks on the gold plated
               connector pins.
6644-2214                                                                                          9
Environmental conditions
 Isolation between interfaces
 Power Interface to all other        2.8 kV DC 2.0 kV RMS @ 50 Hz and 60 s duration
 TX signal Interface to all other    2.1 kV DC 1.5 kV RMS @ 50 Hz and 60 s duration
 TX shield Interface to all other    1.5 kV DC 1.0 kV RMS @ 50 Hz and 60 s duration
 Environmental
 Temperature, operating                      –25 to +70°C (SDW-550),
                                             –25 to +65°C (SDW-541)
                                             –25 to +60°C (SDW-532)
 Temperature, storage and transportation     –25 to +70°C
 Relative humidity, operating                5 to 95% (non-condensing)
 Relative humidity,                          5 to 95% (condensation allowed outside packaging)
 storage and transportation
 Altitude, operating                         2000 m/70 kPa
 Mechanical
 Dimension (W x H x D)              35 x 121 x 119 mm
 Weight                             0.2 kg
 Mounting                           DIN-rail
 Degree of protection               IP21
 Configuration
 Auto configured (auto-negotiation) or manually setting of speed and duplex of individual TX port,
 by DIP-switches.
 Port mirror function is possible to set with DIP-switch. With the port mirror function active the
 switch will copy all outgoing traffic to port 1. This can be used to monitor all traffic going out
 from the switch. Packets may be discarded if the total throughput exceeds the port speed of port
 1.
Fibre optic power budget
 Model                                 Multimode      Singlemode Singlemode Singlemode
                                        MM-xx2         SM-SC15    SM-LC15    SM-LC40
 Transmitted wavelength                 1310 nm         1310 nm    1310 nm    1310 nm
 Min. output power, transmitter         –19 dBm         –15 dBm    –15 dBm     –5 dBm
 Max. output power, transmitter         –12 dBm          –8 dBm     -8 dBm      0 dBm
 Input sensitivity, receiver            –31 dBm         –34 dBm    –31 dBm    –34 dBm
 Min. power budget                       12 dBm          19 dBm     16 dBm     29 dBm
 Max. power budget                       19 dBm          26 dBm     23 dBm     34 dBm
 Recommended fibre cable and             50/125           9/125      9/125      9/125
 core / cladding diameter               62.5/125         10/125     10/125     10/125
Attenuation in connectors / splices
 Type                                                    Normal attenuation
 Connector                                                  0.2 - 0.4 dBm
 Fusion splice                                                 0.1 dBm
 Mechanical splice                                             0.2 dBm
10                                                                                        6644-2214
Description
The SDW-550 is an Industrial Ethernet 5-port switch.
All ports support auto-negotiation, but DIP-switches also allow speed and duplex
configuration of any individual TX port. It is also possible to set up one port to monitor
traffic to/from the switch.
The SDW-550 has been designed to meet high industrial specifications, providing very
high dependability in harsh environmental conditions.
Features:
       … TX shields individually isolated
       … Wide DC power range 12 – 48 VDC
       … Wide temperature range
       … Automatic MDI/MDI-X crossover
       … LED indicators for Power, Speed, Duplex, Link and Traffic
       … Port monitoring
       … 35 mm DIN rail mounting
       … Enable or disable of flow control
Example of applications are:
       … 5-port switch
       … Ethernet isolator, for STP networks
6644-2214                                                                                11
Interface specifications
 Power SDW-500 series
 Rated voltage              12 –48 VDC, polarity protected
 Operating voltage          9.6 – 57.6 VDC
 Rated current              @12 VDC power input
                            SDW-550                       320   mA
                            SDW-541-MM-SC2                450   mA
                            SDW-541-SM-LC15               450   mA
                            SDW-541-SM-SC15               350   mA
                            SDW-541-MM-LC2                350   mA
                            SDW-532-MM-SC2                600   mA
                            SDW-532-SM-LC15               450   mA
                            SDW-532-SM-SC15               450   mA
                            SDW-532-SM-LC40               450   mA
                            SDW-532-MM-LC2                450   mA
 Rated frequency            DC
 Connection                 Detachable screw terminal
 Connector size             0.2 – 2.5 mm² (AWG 24-12)
 Ethernet TX
 Electrical specification   IEEE std 802.3. 2000 edition
 Data rate                  10 Mbit/s or 100 Mbit/s, manual or auto
 Duplex                     Full or half, manual or auto
 Connection                 SC, ST or LC
 Circuit type               Optical
 Transmission range         100 m
 Ethernet FX
 Electrical specification   IEEE std 802.3. 2000 edition
 Data rate                  10 Mbit/s or 100 Mbit/s, manual or auto
 Duplex                     Full or half, manual or auto
 Connection                 SC, ST or LC
 Circuit type               Optical
 Transmission range         100 m
12                                                                    6644-2214
Connections
                                                          LED indicators
Network
RJ-45 connection
                                                          Network
                                                          Fibre connection
                                                          or RJ-45 connection
                       Power connection
Available models:
… SDW-550  10/100Base-T/TX: 5 ports
… SDW-541  10/100Base-T/TX: 4 ports 100Base-FX: 1 port
… SDW-532  10/100Base-T/TX: 3 ports 100Base-FX: 2 ports
6644-2214                                                                       13
Power
The SDW-500 series supports redundant power connection.
The positive input are +VA and +VB, the negative input
for both supplies are COM.
The power is drawn from
the input with the highest
voltage.
3-pos screw terminal   Description   Power
                                                                         3
          1            COM           0V
                                                                         2
          2            +VA           A: 9.6 – 57.6 VDC
                                                                         1
          3            +VB           B: 9.6 – 57.6 VDC
TX
Ethernet TX connection (RJ-45 connector), automatic MDI/MDI-X crossover.
Contact Signal Name Direction Description/Remark
                                                                         8
   1        TD+      In/Out   Transmitted/Received data                  7
                                                                         6
   2        TD–      In/Out   Transmitted/Received data                  5
                                                                         4
                                                                         3
   3        RD+      In/Out   Transmitted/Received data                  2
                                                                         1
   4          –         –     –
   5          –         –     –
   6        RD–      In/Out   Transmitted/Received data
   7          –         –     –
   8          –         –     –
 Shield       –         –     HF-connected
CAT 5 cable is recommended.
Unshielded (UTP) or shielded (STP) connector might be used.
FX SC Multi- or single mode (optional)
Ethernet FX connection.
1300 nm multi- or singlemode fibre tranceiver with SC-connector.
The dust protection plug shall be mounted when no fibre is connected.
FX ST Multi mode (optional)
Ethernet FX connection.
1300 nm multi mode fibre tranceiver with ST-connector.
The dust protection plugs shall be mounted when no fibre is connected.
FX LC Multi- or single mode (optional)
Ethernet FX connection.
1300 nm singlemode fibre transceiver with LC-connector.
The dust protection plug shall be mounted when no fibre is connected.
14                                                                           6644-2214
LED indicators
At power on the PWR flashes during initialising.
Indicators (LED)	Power (PWR)
                   Link (LINK) of every port
                   Speed (SPD) and duplex (DPX) of TX ports
LED         Status       Indication of
PWR         ON           Internal power, initialising OK
            Slow flash   Initialisation progressing
            Fast flash   Initialisation error
LINK        OFF          No Ethernet link
            ON           Good Ethernet link
            Flash        Ethernet data is transmitted or received, traffic indication
SPD         OFF          10 Mbit/s
(TX only)   ON           100 Mbit/s
DPX         OFF          Half duplex
(TX only)   ON           Full duplex
6644-2214                                                                               15
Installation
Mounting / Removal
                   WARNING - HAZARDOUS VOLTAGE
                   Do not open an energized product. Hazardous voltage may occur
                   when connected to a power supply.
                   CAUTION - ELECTROSTATIC DISCHARGE (ESD)
                   Prevent electrostatic discharge damages to internal electronic
                   parts by discharging your body to a grounding point (e.g. use a
                   wrist strap).
                                                        Mounting
                                                        This product should be mounted on
                                               CLICK!
                                                         35 mm DIN-rail which is horizontally
                                                         mounted on a wall or cabinet
                                                         backplate.
                                                                                         10 mm *
                                                                                        (0.4 inches)
Cooling                                                                                                25 mm
This product uses convection cooling.
To avoid obstructingCLICK!the airflow around the
product, use the following spacing rules.
Minimum spacing 25 mm (1.0 inch) above /
below and 10 mm (0.4 inches) left / right the
product.
Spacing is recommended for the use of prod-                * S pacing (left/right) recommended for    25 mm
                                                             full operating temperature range
uct in full operating temperature range and
service life.
Removal Press down the black support at the back of the product,
see figure.
16                                                                                                     6644-2214
DIP switch settings SDW-550
DIP-switches are accessible under the lid on top of the product. DIP-switches are used
to configure the product.
                  WARNING - HAZARDOUS VOLTAGE
                  Do not open an energized product. Hazardous voltage may occur
                  when connected to a power supply.
                  CAUTION - ELECTROSTATIC DISCHARGE (ESD)
                  Prevent electrostatic discharge damages to internal electronic
                  parts by discharging your body to a grounding point (e.g. use a
                  wrist strap).
NOTE
When configuration via DIP-switches, the settings of DIP-switches configure the product
only after a reboot (power off/on).
Observe this when the DIP-switches are configured:
… Speed and duplex setting only valid when auto-negotiation is disabled.
… When monitoring selected all outgoing packets from the switch is also copied to the
  port 1.
… Speed and duplex switch settings are ignored for FX ports.
… If auto-negotiation and auto MDI/MDI-X disabled all TX ports support MDI-X
   configuration.
6644-2214                                                                                17
                              S3       S2           S1
                Port 1 settings                                     Port 3 settings
          ON	
                             Auto-negotiation and             ON	
                                                                                 Auto-negotiation and
     S1                      auto MDI/MDI-X disabled     S1                      auto MDI/MDI-X disabled
          	1	2	3	4	5	6	7	8                                    	1	2	3	4	5	6	7	8
          ON	
                             Auto-negotiation and             ON	
                                                                                 Auto-negotiation and
     S1                      auto MDI/MDI-X enabled      S1                      auto MDI/MDI-X enabled
          	1	2	3	4	5	6	7	8                                    	1	2	3	4	5	6	7	8
          ON	
                             10 Mbit/s speed selected         ON	
                                                                                 10 Mbit/s speed selected
     S1                                                  S1
          	1	2	3	4	5	6	7	8                                    	1	2	3	4	5	6	7	8
          ON	
                             100 Mbit/s speed selected        ON	
                                                                                 100 Mbit/s speed selected
     S1                                                  S1
          	1	2	3	4	5	6	7	8                                    	1	2	3	4	5	6	7	8
          ON	
                             Half duplex selected             ON	
                                                                                 Half duplex selected
     S1                                                  S2
          	1	2	3	4	5	6	7	8                                    	1	2	3	4	5	6	7	8
          ON	
                             Full duplex selected             ON	
                                                                                 Full duplex selected
     S1                                                  S2
          	1	2	3	4	5	6	7	8                                    	1	2	3	4	5	6	7	8
                Port 2 settings                                     Port 4 settings
          ON	
                             Auto-negotiation and             ON	
                                                                                 Auto-negotiation and
     S1                      auto MDI/MDI-X disabled     S2                      auto MDI/MDI-X disabled
          	1	2	3	4	5	6	7	8                                    	1	2	3	4	5	6	7	8
          ON	
                             Auto-negotiation and             ON	
                                                                                 Auto-negotiation and
     S1                      auto MDI/MDI-X enabled      S2                      auto MDI/MDI-X enabled
          	1	2	3	4	5	6	7	8                                    	1	2	3	4	5	6	7	8
          ON	
                             10 Mbit/s speed selected         ON	
                                                                                 10 Mbit/s speed selected
     S1                                                  S2
          	1	2	3	4	5	6	7	8                                    	1	2	3	4	5	6	7	8
          ON	
                             100 Mbit/s speed selected        ON	
                                                                                 100 Mbit/s speed selected
     S1                                                  S2
          	1	2	3	4	5	6	7	8                                    	1	2	3	4	5	6	7	8
          ON	
                             Half duplex selected             ON	
                                                                                 Half duplex selected
     S1                                                  S2
          	1	2	3	4	5	6	7	8                                    	1	2	3	4	5	6	7	8
          ON	
                             Full duplex selected             ON	
                                                                                 Full duplex selected
     S1                                                  S2
          	1	2	3	4	5	6	7	8                                    	1	2	3	4	5	6	7	8
18                                                                                                6644-2214
             Port 5 settings                                             Port mirroring settings
       ON	
                          Auto-negotiation and                                               No monitoring selected
  S2                      auto MDI/MDI-X disabled                  S2
                                                                         ON	
       	1	2	3	4	5	6	7	8
                                                                         	1	2	3	4	5	6	7	8
       ON	
                          Auto-negotiation and                                               Monitoring selected
  S2                      auto MDI/MDI-X enabled                   S2
                                                                         ON	
       	1	2	3	4	5	6	7	8
                                                                         	1	2	3	4	5	6	7	8
       ON	
                          10 Mbit/s speed selected
  S2
       	1	2	3	4	5	6	7	8
       ON	
                          100 Mbit/s speed selected
  S2
       	1	2	3	4	5	6	7	8
                                                                          Flow control selected
                          Half duplex selected                           ON	
                                                                                       Flow control selected
       ON	
  S2                                                               S3
       	1	2	3	4	5	6	7	8                                                  	1	 2	 3	 4
                          Full duplex selected                           ON	
                                                                                       No flow control selected
       ON	
  S2                                                               S3
       	1	2	3	4	5	6	7	8                                                  	1	 2	 3	 4
                                            Factory settings
       ON	                                            ON	                                            ON	
  S1                                             S2                                             S3
       	1	2	3	4	5	6	7	8                               	1	2	3	4	5	6	7	8                               	1	 2	 3	 4
6644-2214                                                                                                             19
DIP switch settings SDW-541 and SDW-532
DIP-switches are accessible under the lid on top of the product. DIP-switches are used
to configure the product.
                  WARNING - HAZARDOUS VOLTAGE
                  Do not open an energized product. Hazardous voltage may occur
                  when connected to a power supply.
                  CAUTION - ELECTROSTATIC DISCHARGE (ESD)
                  Prevent electrostatic discharge damages to internal electronic
                  parts by discharging your body to a grounding point (e.g. use a
                  wrist strap).
NOTE
When configuration via DIP-switches, the settings of DIP-switches configure the product
only after a reboot (power off/on).
Observe this when the DIP-switches are configured:
… Speed and duplex setting only valid when auto-negotiation is disabled.
… When monitoring selected all outgoing packets from the switch is also copied to the
  port 1.
… Speed and duplex switch settings are ignored for FX ports.
… If auto-negotiation and auto MDI/MDI-X disabled all TX ports support MDI-X
   configuration.
20                                                                                  6644-2214
              Port 1 settings                                                 S1
        ON	
                           Auto-negotiation and                                                S2
   S1                      auto MDI/MDI-X disabled
        	1	2	3	4	5	6	7	8
        ON	
                           Auto-negotiation and
   S1                      auto MDI/MDI-X enabled
        	1	2	3	4	5	6	7	8
        ON	
                           10 Mbit/s speed selected
   S1
        	1	2	3	4	5	6	7	8
        ON	
                           100 Mbit/s speed selected
   S1
        	1	2	3	4	5	6	7	8
                           Half duplex selected
                                                                     Port 4 settings*
   S1
        ON	
                                                               ON	
                                                                            Auto-negotiation and auto MDI/
                                                          S2                MDI-X disabled
        	1	2	3	4	5	6	7	8
                           Full duplex selected                	1	2	3	4	5
   S1
        ON	
                                                               ON	
                                                                            Auto-negotiation and auto MDI/
                                                          S2                MDI-X enabled
        	1	2	3	4	5	6	7	8
                                                               	1	2	3	4	5
                                                               ON	
                                                                            10 Mbit/s speed selected
                                                          S2
              Port 2 settings                                  	1	2	3	4	5
        ON	
                           Auto-negotiation and                ON	
                                                                            100 Mbit/s speed selected
   S1                      auto MDI/MDI-X disabled        S2
        	1	2	3	4	5	6	7	8                                       	1	2	3	4	5
        ON	
                           Auto-negotiation and                ON	
                                                                            Half duplex selected
   S1                      auto MDI/MDI-X enabled         S2
        	1	2	3	4	5	6	7	8                                       	1	2	3	4	5
        ON	
                           10 Mbit/s speed selected            ON	
                                                                            Full duplex selected
   S1                                                     S2
        	1	2	3	4	5	6	7	8                                       	1	2	3	4	5
        ON	
                           100 Mbit/s speed selected
   S1                                                  * Setting of port 4 is only possible when using
        	1	2	3	4	5	6	7	8                                  SDW-541.
        ON	
                           Half duplex selected           These settings are ignored when using SDW-532
   S1
        	1	2	3	4	5	6	7	8
        ON	
                           Full duplex selected                Port mirroring settings
   S1
        	1	2	3	4	5	6	7	8                                       ON	
                                                                            No monitoring selected
                                                          S2
                                                               	1	2	3	4	5
                                                                            Monitoring selected
              Port 3 settings
                                                               ON	
                                                          S2
        ON	
                           Auto-negotiation and                	1	2	3	4	5
   S1                      auto MDI/MDI-X disabled
        	1	2	3	4	5	6	7	8
        ON	
                           Auto-negotiation and                      Factory settings
   S1                      auto MDI/MDI-X enabled              ON	                       ON	
        	1	2	3	4	5	6	7	8                                  S1                        S2
        ON	
                           10 Mbit/s speed selected            	1	2	3	4	5	6	7	8          	1	2	3	4	5
   S1
        	1	2	3	4	5	6	7	8
        ON	
                           100 Mbit/s speed selected
   S1
        	1	2	3	4	5	6	7	8
        ON	
                           Half duplex selected
   S2
        	1	2	3	4	5	6	7	8
        ON	
                           Full duplex selected
   S2
        	1	2	3	4	5	6	7	8
6644-2214                                                                                                 21
       Westermo • SE-635 35 Stora Sundby, Sweden
        Tel +46 16 42 80 00  Fax +46 16 42 80 01
               E-mail: [email protected]
                  www.westermo.com
REV. I  6644-2214  2021-01  Westermo Network Technologies AB, Sweden