SURGE ARRESTERS
Ensto Overhead
Surge Arresters with Insulation Piercing
Connector, SE 45 and SE 46
Overvoltage protection is
needed e.g. for electricity distribution and supply, consumer in house
supplies and distribution
transformers due to lightning strokes and switching
actions. The most effective
means of protection is the
use of surge arresters in
the vicinity of electricity
equipment.
Thanks to the special construction of the connectors, Ensto surge
arresters are screwed to the lower
part of the connector giving thus a
proper electrical connection.
Connectors are equipped with
shear head bolts and can be
installed using standard tools (no
need for a torque wrench). The
design enables live line installation,
as the shear heads are insulated
from the connector body. A wide
range of different electrical parameters are offered.
Replacing a defective surge
arrester is easily done: there is
no need to unscrew the connector
from the conductor, you only screw
the defective surge arrester off and
a new one on.
Application
Protection of low voltage networks
against lightning and switching overvoltages. From low voltage side
of a transformer up to measuring
instruments. The surge arresters
can be connected to all kinds of low
voltage overhead lines.
Features
Outdoor application, UV radiation resistant and moisture proof
housing
Operation and storage temperatures: -60C to + 70C
Humidity up to 90 %
Altitude up to 2000 m
Advantages
Delivered with or without disconnector on request
incl. failure indicator, easy to see
from 10 m distance
Easy to connect, no special
mounting tools are required
Easy to replace a defective surge
arrester
Suits for most demanding
weather conditions, temperature
range -60C to + 70C
Technical data for surge
arresters
For voltage systems up to 660 V
Network frequency up to 62 Hz
Nominal discharge current
In 8/20 s 5 kA or 10 kA
Maximum discharge current
Imax 8/20 s 25 kA or 40 kA
High current impulse 4/10 s
40 kA or 65 kA
Classication acc. IEC 61643-1 class
II and DIN/VDE 0675/6 class A
Tested according to the standard
IEC 61643-1,1998-02, Surge
protective devices connected to
low voltage power distribution
systems Part 1: Performance requirements and testing methods
and DIN/VDE 0675/6
Surge Arresters with Insulation Piercing
Connector SE 45
SE 45 series includes a new
piercing connector specially designed for surge
arrester. This connector is
used when installing the
surge arrester on insulated
LV overhead lines. It can be
installed on insulated Al/Cu
conductors with cross section range 10 - 150 mm2.
CAT. NO.
EAN
SE45.128-5
SE45.144-5
SE45.166-5
SE45.128-10
SE45.144-10
SE45.166-10
6418677428906
6418677428913
6418677428920
6418677428937
6418677428944
6418677428951
CONDUCTOR
mm2
DIA mm
10 -150
6.8 18.5
10 -150
6.8 18.5
10 -150
6.8 18.5
10 -150
6.8 18.5
10 -150
6.8 18.5
10 -150
6.8 18.5
SE45.328-5
SE45.344-5
SE45.366-5
SE45.328-10
SE45.344-10
SE45.366-10
6418677434969
6418677434976
6418677434983
6418677432767
6418677433382
6418677433399
10 -150
10 -150
10 -150
10 -150
10 -150
10 -150
CAT. NO.
CONTINUOUS
OPERATING
VOLTAGE
V
280
440
660
280
440
660
SE45.128-5
SE45.144-5
SE45.166-5
SE45.128-10
SE45.144-10
SE45.166-10
SE45.328-5
SE45.344-5
SE45.366-5
SE45.328-10
SE45.344-10
SE45.366-10
280
440
660
280
440
660
6.8 18.5
6.8 18.5
6.8 18.5
6.8 18.5
6.8 18.5
6.8 18.5
RATED
VOLTAGE
DISCHARGE PROTECTION
CURRENT
LEVEL
kA
V peak
5
1150
5
1800
5
2700
10
1150
10
1800
10
2700
5
5
5
10
10
10
1150
1800
2700
1150
1800
2700
SURGE ARRESTER
SGA128-5
SGA144-5
SGA166-5
SGA128-10
SGA144-10
SGA166-10
WEIGHT
kg
0.22
0.22
0.22
0.22
0.22
0.22
PACKAGE
pcs
20
20
20
20
20
20
SGA328-5
SGA344-5
SGA366-5
SGA328-10
SGA344-10
SGA366-10
0.22
0.22
0.22
0.22
0.22
0.22
20
20
20
20
20
20
ENERGY
ABSORPTION
EARTHING
TERMINAL
M8 screw
DISCONNECTOR
J
700
1100
1600
1100
1750
2600
+
+
+
+
+
+
700
1100
1600
1100
1750
2600
+
+
+
+
+
+
+
+
+
+
+
+
Surge Arresters with Insulation Piercing
Connector SE 46
EAN
SE46.128-5
6418677428975
SE46.144-5
6418677428982
SE46.166-5
6418677428999
SE46.128-10
6418677429002
SE46.144-10
6418677429019
SE46.166-10
6418677429026
SE46.328-5
6418677432736
SE46.344-5
6418677432804
SE46.366-5
6418677430695
SE46.328-10
6418677432774
SE46.344-10
6418677433405
SE46.366-10
6418677433412
CAT. NO.
CONTINUOUS
OPERATING
VOLTAGE
V
280
440
660
280
440
660
SE46.128-5
SE46.144-5
SE46.166-5
SE46.128-10
SE46.144-10
SE46.166-10
SE46.328-5
SE46.344-5
SE46.366-5
SE46.328-10
SE46.344-10
SE46.366-10
280
440
660
280
440
660
CONDUCTOR
mm2
DIA mm
Al 10-95,
3 -16
Cu 1,5-70
Al 10-95,
3 -16
Cu 1,5-70
Al 10-95,
3 -16
Cu 1,5-70
Al 10-95,
3 -16
Cu 1,5-70
Al 10-95,
3 -16
Cu 1,5-70
Al 10-95,
3 -16
Cu 1,5-70
Al 10-95,
Cu 1,5-70
Al 10-95,
Cu 1,5-70
Al 10-95,
Cu 1,5-70
Al 10-95,
Cu 1,5-70
Al 10-95,
Cu 1,5-70
Al 10-95,
Cu 1,5-70
WEIGHT
kg
PACKAGE
pcs
SGA128-5
0.25
20
SGA144-5
0.25
20
SGA166-5
0.25
20
SGA128-10
0.25
20
SGA144-10
0.25
20
SGA166-10
0.25
20
3 -16
SGA328-5
0.25
20
3 -16
SGA344-5
0.25
20
3 -16
SGA366-5
0.25
20
3 -16
SGA328-10
0.25
20
3 -16
SGA344-10
0.25
20
3 -16
SGA366-10
0.25
20
61
44
61
RATED
VOLTAGE
DISCHARGE PROTECTION
CURRENT
LEVEL
kA
V peak
5
1150
5
1800
5
2700
10
1150
10
1800
10
2700
5
5
5
10
10
10
SURGE ARRESTER
1150
1800
2700
1150
1800
2700
ENERGY
ABSORPTION
EARTHING
TERMINAL
M8 screw
DISCONNECTOR
J
700
1100
1600
1100
1750
2600
+
+
+
+
+
+
700
1100
1600
1100
1750
2600
+
+
+
+
+
+
+
+
+
+
+
+
160
CAT. NO.
conductors with cross section range 10 95 mm2 and
Cu conductors with cross
section range 1,5 70 mm2
and branch connection with
the same range of conductors.
160
The design of SE 46 series
enables installation on
insulated conductor and
branch connection, the
same connector is used
for both. Connector can be
installed on insulated Al
44
UTILITY NETWORKS
ENSTO SEKKO OY
PL 51
06101 PORVOO, FINLAND
PUH. 0204 76 21
FAX 0204 76 2770
[email protected]
WWW.ENSTO.COM