MEASUREMENTS
Name of work: Special repair to Regional Meteorological Centre , College Road,
Chennai -06 . SH:- Providing window type mosquito proof shutter to all the windows of
canteen for trainees hostel.
Name of Agency : M/s Shri .Premkumar
Aggrement No :
Date of commencement :
Due Date of Completion :
Date of Abstract :
Sl.No. Description of Items Qty Unit Rate Amount
Providing and fixing aluminium work for
doors, windows, ventilators and partitions with
extruded built up standard tubular sections/
appropriate Z sections and other sections of
approved make conforming to IS: 733 and IS:
1 1285, fixing with dash fasteners of required dia
and size, including necessary filling up the gaps
at junctions, i.e. at top, bottom and sides with
required EPDM rubber/neoprene gasket etc.
Aluminium sections shall be smooth, rust free,
straight, mitred and jointed mechanically
wherever
G.I required
fasteners 100 xincluding
8 mm sizecleat angle, frame
for fixing
Aluminium
to snapplastic
finished wall, beading for glazing
packers, / caps
plastic
paneling, C.P. brass / stainless steel screws,
and necessary stainless steel screws etc.Profile all
complete as per architectural drawings
of frame & sash shall be mitred cut and fusionand the
directions of Engineer-in-charge.
welded at all (Glazing,shall
corners, mullion (if required)
paneling and dash fasteners to be paid forof
be also fusion welded including drilling
separately) :
holes for fixing hardware's and drainage of
water etc.After fixing frame the gap between
frame and adjacent finished wall shall be filled
with weather proof silicon sealant over backer
rod of required size and of approved quality, all
complete as per approved drawing & direction
of Engineer-in-Charge. (Single / double glass
panes and silicon sealant shall be paid
separately)
1.1 For fixed portion .
Anodised aluminium (anodised transparent or
dyed to required shade according to IS: 1868,
1.1.1 Minimum anodic coating of grade AC 15)
B/F Page / TCMB 0.68
Total 0.68 sqm 11285.37 7724
Aggrement Quantity 1.00
Casement window double panels with S.S.
friction hinges (300 x 19 x 1.9 mm) made of
(small series) frame 47 x 50 mm, sash 47 x 68
mm & mullion 47 x 68 mm all having wall
1.2 thickness of 1.9 ± 0.2 mm and single glazing
bead of appropriate dimension. (Area of
window above 0.75 sqm upto 1.50 sqm).
B/F Page / TCMB 19.23
Total 19.23 sqm 10374.06 207481
Aggrement Quantity 20.00
Providing and fixing factory made uPVC white
colour fixed glazed windows/ventilators
comprising of uPVC multi-chambered frame
and mullion (where ever required) extruded
profiles duly reinforced with 1.60 ± 0.2 mm
thick galvanized mild steel section made from
roll forming process of required length (shape
& size according to uPVC profile), uPVC
extruded glazing beads of appropriate
dimension, EPDM gasket,G.I fasteners 100 x 8
mm size for fixing frame to finished wall,
plastic packers, plastic caps and necessary
stainless steel screws etc. Profile of frame shall
2 be mitred cut and fusion welded at all corners,
mullion (if required) shall be also fusion
welded including drilling of holes for fixing
hardware's and drainage of water etc. After
fixing frame the gap between frame and
adjacent finished wall shall be filled with
weather proof silicon sealant over backer rod of
required size and of approved quality,all
complete as per approved drawing & direction
of Engineer-in-Charge. (Single/double glass
panes and silicon sealant shall be paid
separately).
Note: For uPVC frame,sash and mullion
extruded profiles minus 5% tolerance in
dimension i.e. in depth & width of profile shall
be acceptable.Variation in profile dimension in
higher side shall be accepted but no extra
payment on this account shall be made.
Fixed window / ventilator made of (small
series) frame 47 x 50 mm & mullion 47 x 68
mm both having wall thickness of 1.9 ± 0.2
2.1
mm and single glazing bead of appropriate
dimension. (Area upto 0.75 sqm.)
B/F Page / TCMB 0.51
Total 0.51 sqm 7709.71 3855
Aggrement Quantity 0.50
3 Providing and fixing Fly proof stainless steel
grade 304 wire gauge with 0.5 mm dia. wire
and 1.4mm wide aperture in UPVC door,
window, ventilator shutters and partitions etc.
with UPVC beading etc. complete as per the
architectural drawings and the directions of
Engineer-in-charge
3.1 Fly proof stainless steel grade 304 wire gauge
with 0.5 mm dia. wire and 1.4mm wide
aperture
B/F Page / TCMB 22.48
Total 22.48 sqm 1289.54 28993
Aggrement Quantity 19.00
Filling the gap in between UPVC / aluminium
frame & adjacent RCC/ Brick/ Stone work by
providing weather silicon sealant over backer
4
rod of approved quality as per architectural
drawings and direction of Engineer-in-charge
complete.
4.1 Upto 5mm depth and 5 mm width
B/F Page / TCMB 68.12
Total 68.12 sqm 94.55 6441
Aggrement Quantity 70.00
TOTAL 254493.24
Less cl 12% quated by contractor 27.27% below 69400.31
185092.93
EXTRA ITEM
Removing dry or oil bound distemper,water
proofing cement paint and the like by
scrapping, sand papering and preparing the
EI-1
surface smooth including necessary repairs to
scratches etc. complete.
B/F Page / TCMB 171.75
Total 171.75 sqm 15.80 2713
Providing and applying white cement based
putty of average thickness 1 mm, of approved
EI-2 brand and manufacturer, over the plastered wall
surface to prepare the surface even and smooth
complete.
B/F Page / TCMB 171.75
Total 171.75 sqm 99.66 17116
Wall painting with acrylic emulsion paint of
approved brand and manufacture to give an
EI-3
even shade :
EI-3.1 Two or more coats on new work
B/F Page / TCMB 171.75
Total 171.75 sqm 111.34 19123
Wall painting with plastic emulsion paint of
EI-4 approved brand and manufacture to give an
even shade:
One or more coats on old work
B/F Page / TCMB 213.58
Total 213.58 sqm 73.26 15648
TOTAL 239693.19
SAY 239693.00
RECOVERY
Security Deposit @ 2.50% as
1 per agreement 4800.00 4800.00
2 Income tax @ 1.00% 2397.00 2397.00
3 LW Cess 1% on work done 2397.00 2397.00
4 SGST 1% 2397.00 2397.00
5 CGST 1% 2397.00 2397.00
Total Recoveries 14388.00 -14388.00
Rs 225305.00
SAY RS. 225305.00
Certificate that:-
The work has been carried out by the contractor as per CPWD
1 specifications and as direction of the Engineer-In-Charge.
2 No register complaints has been received towards non-payment of wages.
Contractor has made payment as per minimum wages to the labours
3 through online/ Demand Draft.
The water has been arranged by the contractor or necessary recovery
4 towards water charges has been recovered.
All recoveries as per agreement condition in respect of security deposite,
5 Income tax, GST, Labour welfare cess has been recovered.
6 The quantity of material for which security advance made are fully
recovered.
7 Required technical staff as per clause-36 has been engaged by the
Agency.
Necessary recovery in respect of water proofing item as a guarantee has
8 been recovered.
9 Fortnight labour report(FLR) has been submitted by the agency
Assistant Engineer
CCSD-1/I, CPWD, CHENNAI
CC Ist & Final Bill in respect of Shri .G.Premkumar is submitted to
EE/CCD -I/CPWD/ Chennai-06 for pass and payment.
MEASUREMENTS
Name of work:-Special repair to Regional Meteorological Centre , College Road, Chennai -06 .
SH:- Providing window type mosquito proof shutter to all the windows of canteen for trainees
hostel.
Name of Agency : SHRI . G.Premkumar
Aggrement No :
Date of commencement :
Due Date of Completion :
Actual Date of Completion : Work in progress
Date of Measurement:
Agrt.No Description Of Items Nos Length Breadth Depth Qty
Providing and fixing factory made uPVC white colour casement/casement cum fixed
glazed windows comprising of uPVC multichambered frame, sash and mullion (where
ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild
steel section made from roll forming process of required length (shape & size according to
1 uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket,
stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement
handles,
G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic
caps and necessary stainless steel screws etc.Profile of frame & sash shall be mitred cut
and fusion welded at all corners, mullion (if required) shall be also fusion welded
including drilling of holes for fixing hardware's and drainage of water etc.After fixing
frame the gap between frame and adjacent finished wall shall be filled with weather proof
silicon sealant over backer rod of required size and of approved quality, all complete as per
approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and
silicon sealant shall be paid separately)
Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerancein
dimension i.e. in depth & width of profile shall be acceptable. Variation in profile
dimension in higher side shall be accepted but no extra payment on this account shall be
made.
Casement window single panel with S.S. friction hinges (300 x 19 x 1.9 mm), made of
(small series) frame 47 x 50 mm & sash 47 x 68 mm both having wall thickness of 1.9 ±
1.1 0.2 mm and single glass pane glazing bead of appropriate dimension. (Area of window
upto 0.75 sqm.)
grinder room 1 x 1 0.59 1.16 0.68
C/O page: TMB Total 0.68
cum
Submitted by Checked by
6
Agency AE
C.P.W.A-23 CMB:
Casement window double panels with S.S. friction hinges (300 x 19 x 1.9 mm) made of
(small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall
thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of
1.2 window above 0.75 sqm upto 1.50 sqm).
Dinning Hall windows 4 x 1 1.72 1.00 6.88
kitchen 1 x 1 2.34 1.11 2.60
grinder room 1 x 1 1.20 1.16 1.39
washroom 1 x 1 1.20 1.15 1.38
kitchen 1 x 1 1.17 1.13 1.32
store room 1 x 1 1.15 1.20 1.38
washroom 2 1 x 1 1.14 1.13 1.29
service room 1 x 1 1.18 1.12 1.32
staff room 1 x 1 1.16 1.44 1.67
C/O page: TMB Total 19.23
sqm
Providing and fixing factory made uPVC white colour fixed glazed windows/ventilators
comprising of uPVC multi-chambered frame and mullion (where ever required) extruded
profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from
roll forming process of required length (shape & size according to uPVC profile), uPVC
extruded glazing beads of appropriate dimension, EPDM gasket,G.I fasteners 100 x 8 mm
size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless
steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners,
mullion (if required) shall be also fusion welded including drilling of holes for fixing
2
hardware's and drainage of water etc. After fixing frame the gap between frame and
adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of
required size and of approved quality, all complete as per approved drawing & direction of
Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid
separately).
Note: For uPVC frame,sash and mullion extruded profiles minus 5% tolerance in
dimension i.e. in depth & width of profile shall be acceptable.Variation in profile
dimension in higher side shall be accepted but no extra payment on this account shall be
made.
Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68
mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate
2.1 dimension. (Area upto 0.75 sqm.)
toilet 1 x 1 0.59 0.86 0.51
C/O page: TMB Total 0.51
sqm
Submitted by Checked by
7
Agency AE
C.P.W.A-23 CMB:
3 Providing and fixing Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. wire
and 1.4mm wide aperture in UPVC door, window, ventilator shutters and partitions etc.
with UPVC beading etc. complete as per the architectural drawings and the directions of
Engineer-in-charge
3.1 Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. wire and 1.4mm wide
aperture
Dinning Hall windows 4 x 12 0.40 0.78 14.98
kitchen 1 x 4 0.41 0.90 1.48
grinder room 1 x 2 0.41 0.94 0.77
small window 1 x 1 0.37 0.96 0.36
toilet 1 x 1 0.46 0.76 0.35
wash room 1 x 2 0.41 0.93 0.76
kitchen 1 x 2 0.40 0.91 0.73
store room 1 x 2 0.38 0.99 0.75
wash room 2 1 x 2 0.38 0.91 0.69
gallery area 1 x 2 0.40 0.91 0.73
staff room 1 x 3 0.31 0.96 0.89
C/O page: TMB Total 22.48
sqm
Filling the gap in between UPVC / aluminium frame & adjacent RCC/ Brick/ Stone work
4 by providing weather silicon sealant over backer rod of approved quality as per
architectural drawings and direction of Engineer-in-charge complete.
4.1 Upto 5mm depth and 5 mm width
Dinning Hall windows 4 x 2 1.72 13.76
4 x 2 1.00 8.00
kitchen 1 x 2 2.34 4.68
1 x 2 1.11 2.22
grinder room 1 x 2 1.20 2.40
1 x 2 1.16 2.32
washroom 1 x 2 1.20 2.40
1 x 2 1.15 2.30
kitchen 1 x 2 1.17 2.34
1 x 2 1.13 2.26
store room 1 x 2 1.15 2.30
1 x 2 1.20 2.40
washroom 2 1 x 2 1.14 2.28
1 x 2 1.13 2.26
service room 1 x 2 1.18 2.36
1 x 2 1.12 2.24
staff room 1 x 2 1.16 2.32
1 x 2 1.44 2.88
toilet 1 x 2 0.59 1.18
1 x 2 0.86 1.72
grinder room 1 x 2 0.59 1.18
1 x 2 1.16 2.32
C/O page: TMB Total 68.12
mtr
Submitted by Checked by
8
Agency AE
C.P.W.A-23 CMB:
Removing dry or oil bound distemper,water proofing cement paint and the like by
scrapping, sand papering and preparing the surface smooth including necessary
EI-1 repairs to scratches etc.complete.
varanda 1 x 1 3.83 2.66 10.19
ded window -1 x 1 0.54 1.73 -0.93
window jams 2 x 1 1.73 0.10 0.35
1 x 1 0.54 0.10 0.05
room 3 enterance 1 x 1 1.77 2.66 4.71
1 x 1 1.44 2.66 3.83
-1 x 1 0.59 1.04 -0.61
-1 x 1 1.08 1.96 -2.12
room 8 enterance 1 x 1 1.77 2.66 4.71
1 x 1 1.44 2.66 3.83
-1 x 1 0.59 1.04 -0.61
-1 x 1 1.08 1.96 -2.12
room 1 enterance 1 x 1 2.04 2.66 5.43
-1 x 1 0.59 1.04 -0.61
-1 x 1 1.08 1.96 -2.12
washing area 1st floor 1 x 1 3.81 2.66 10.13
washing area 1 x 2 3.81 2.66 20.27
ded door -1 x 1 1.08 1.96 -2.12
-1 x 1 0.60 1.08 -0.65
ded wash basin -2 x 1 1.56 1.58 -4.93
1 x 1 5.31 2.66 14.12
steps landing area 1 x 1 2.40 2.20 5.28
room 3 1 x 2 5.53 2.60 28.76
1 x 2 8.54 2.60 44.41
ded window -1 x 2 1.66 1.12 -3.72
-1 x 1 1.14 1.12 -1.28
ded door -1 x 1 0.90 1.87 -1.68
-1 x 1 1.04 1.87 -1.94
ded vent -1 x 1 0.59 1.04 -0.61
vent jams 1 x 1 0.59 0.07 0.04
room 8 1 x 2 5.53 1.75 19.36
1 x 2 8.54 1.75 29.89
ded window -1 x 2 1.66 1.12 -3.72
-1 x 1 1.14 1.12 -1.28
ded door -1 x 1 0.90 1.02 -0.92
-1 x 1 1.04 1.02 -1.06
ded vent -1 x 1 0.59 1.04 -0.61
vent jams 1 x 1 0.59 0.07 0.04
C/O page: TMB Total 171.75
sqm
Submitted by Checked by
9
Agency AE
C.P.W.A-23 CMB:
Providing and applying white cement based putty of average thickness 1 mm, of
approved brand and manufacturer, over the plastered wall surface to prepare the
EI-2 surface even and smooth complete.
SAME QUANTITY AS
EXTRA ITEM NO 1 1 x 1 171.75 171.75
C/O page: TMB Total 171.75
sqm
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an
EI-3 even shade :
EI-3.1 Two or more coats on new work
SAME QUANTITY AS
EXTRA ITEM NO 1 1 x 1 171.75 171.75
C/O page: TMB Total 171.75
sqm
Wall painting with plastic emulsion paint of approved brand and manufacture to give an
EI-4 even shade:
One or more coats on old work
EB box 2 x 1 0.61 2.66 3.25
1 x 1 1.77 2.66 4.71
-1 x 1 1.87 1.50 -2.81
room no 3 slabs 4 x 2 1.90 0.41 6.23
4 x 2 0.70 0.41 2.30
4 x 4 0.59 0.41 3.87
room no 8 slabs 4 x 2 1.90 0.41 6.23
4 x 2 0.70 0.41 2.30
4 x 4 0.59 0.41 3.87
beam room 3 & 8 2 x 2 0.38 5.60 8.51
1 x 2 0.30 5.60 3.36
washing area beam. 2 x 1 0.28 3.85 2.16
2 x 1 0.20 1.20 0.48
beam opp to room 3 2 x 1 0.31 3.81 2.36
room 8 bathroom 2 x 1 2.57 0.78 4.01
2 x 1 1.54 0.78 2.40
2 x 1 2.54 0.78 3.96
2 x 1 1.62 0.78 2.53
bathroom cealing room 3 & 8 2 x 1 2.57 1.54 7.92
2 x 1 2.54 1.62 8.23
2 x 1 0.10 1.62 0.32
cealing room 3 & 8 2 x 1 5.53 8.53 94.34
2 x 1 1.43 1.04 2.97
room 3,8 enterance cealing 2 x 1 3.86 2.03 15.67
2 x 1 2.80 1.77 9.91
washing area cealing 1 x 1 3.43 3.80 13.03
1 x 1 1.54 0.95 1.46
C/O page: TMB Total 213.58
sqm
Submitted by Checked by
10
Agency AE
C.P.W.A-23 CMB: