Datasheet
CloudEngine S12700E Series Switches
Datasheet
Huawei CloudEngine S12700E series switches are new core switches designed for next-
generation high-quality campus networks. These purpose-built switches help create a campus
network that improves user experiences, reduces operating costs, and delivers unmatched
security and trustworthiness for a fully connected, wireless era.
Product Overview
Huawei CloudEngine S12700E series switches ("S12700E switches") are flagship core switches in Huawei's CloudCampus
portfolio. By building an intelligent campus core, these feature-rich switches help customers head towards a service experience-
centric campus network that is intelligent and simplified.
CloudEngine S12700E stands out with massive capacity expansion and flexible service upgrade capabilities to protect customer
investments and facilitate their long-term network evolution. Built on Huawei's high-performance full-programmable chipsets,
CloudEngine S12700E delivers 4.8 Tbps of single-slot bandwidth,which can easily scale to 7.2 Tbps simply by upgrading SFUs
in the future. CloudEngine S12700E also offers a broad range of line cards, including 100GE, 40GE, 25GE, 10GE,and GE line
cards, and provides up to 288 x 100GE ports, the unmatched port density in the industry. These give customers flexible choices
to meet their capacity expansion and upgrade needs.
By integrating large-capacity WLAN AC capabilities, a single CloudEngine S12700E can manage up to 10,240 WLAN APs. This
capability, combined with free mobility functionality, achieves fully converged wired and wireless networks and policies, greatly
simplifying network management with users and services at the core.
With a holistic set of reliability, security, and trusted features, CloudEngine S12700E is ideal for building a reliable, secure, and
trustworthy campus core. By using a next-generation cell switching architecture, CloudEngine S12700E ensures non-blocking
service data forwarding on core nodes and guarantees service quality in high-concurrency, large-capacity, and high-load
environments.
Models and Appearances
The S12700E series is available in three models: S12700E-4, S12700E-8, S12700E-12.
CloudEngine S12700E Series Switches Datasheet-V2R21C00 1
S12700E-4 S12700E-8 S12700E-12
Product Model Product Description
S12700E-4 ⚫ A maximum of 96 x 100GE, 96 x 40GE, 160 x 25GE or 192 x 10GE ports
⚫ 4 slots for line cards, 2 slots for Switch Fabric Units (SFUs), 2 slots for Main Processing
Units (MPUs), and 4 slots for power modules
⚫ Switching capacity: 19.2 Tbit/s
⚫ Forwarding performance: 14,400 Mpps
S12700E-8 ⚫ A maximum of 192 x 100GE, 192 x 40GE, 320 x 25GE or 384 x 10GE ports
⚫ 8 slots for line cards, 4 slots for SFUs, 2 slots for MPUs, and 6 slots for power modules
⚫ Switching capacity: 38.4 Tbit/s
⚫ Forwarding performance: 28,800 Mpps
S12700E-12 ⚫ A maximum of 288 x 100GE, 288 x 40GE, 480 x 25GE or 576 x 10GE ports
⚫ 12 slots for line cards, 4 slots for SFUs, 2 slots for MPUs, and 6 slots for power modules
⚫ Switching capacity: 57.6 Tbit/s
⚫ Forwarding performance: 43,200 Mpps
Features and Highlights
Switch Highlights
Fully-programmable Architecture
⚫ Built on chipsets with a fully-programmable architecture, CloudEngine S12700E adapts to the changing forwarding
processes driven by protocol evolution and technology advances. It enables fast and flexible provisioning of new services simply
by upgrading software, without having to replace hardware, thereby protecting customers' investment. In contrast, traditional
ASIC chips use a fixed forwarding architecture and follow a fixed forwarding process; as a result, new services cannot be
provisioned until new hardware is developed to support the services, which may take 1 to 3 years.
CloudEngine S12700E Series Switches Datasheet-V2R21C00 2
Wired and Wireless Convergence
⚫ By integrating WLAN AC capabilities, CloudEngine S12700E eliminates the need to purchase additional WLAN AC
hardware. Each CloudEngine S12700E can manage up to 10,240 APs. With up to 4 Tbps WLAN AC forwarding capacity,
CloudEngine S12700E avoids the performance bottleneck on independent WLAN AC devices. As such, organizations are well
poised to cope with challenges in the high-speed wireless era.
⚫ CloudEngine S12700E supports the unified user management function that authenticates both wired and wireless users,
ensuring a consistent user experience no matter whether they are connected to the network through wired or wireless access
devices. CloudEngine S12700E supports various authentication methods, including PPPoE, 802.1X, MAC address, and Portal
authentication, and is capable of managing users based on user groups, domains, and time ranges. These functions intuitively
control user and service management and enable the transformation from data switching-centered management to service
experience-centered management.
Note: The CloudEngine S12700E series switches can manage 16 APs by default . You can purchase
licenses for more AP management on demand.
Service Experience Assurance
⚫ CloudEngine S12700E supports a 4 GB buffer to cope with the burst data traffic pressure caused by massive concurrent
users. This alleviates the data packet loss and even connection interruption caused by traffic burst.
⚫ In addition, based on the industry-leading HQoS, hierarchical scheduling is performed on network-wide data traffic on the
core nodes of the network to provide differentiated services for different users and applications which are based on IPv4 and
IPv6 protocols, fully ensuring the service quality of key users and key applications and ensuring service experience.
Refined Network Management
⚫ Packet Conservation Algorithm for Internet (iPCA) changes the traditional method that uses simulated traffic for fault
location. iPCA technology monitors network quality for any service flow at any network node, at any time, and without extra
costs. It can quickly detect intermittent service interruptions and accurately identify faulty ports. This cutting-edge fault detection
technology turns "extensive management" into "fine granular management."
⚫ Super Virtual Fabric 2.0 (SVF 2.0) technology can not only virtualize fixed-configuration switches into modular switch line
cards but also virtualize APs as switch ports. With this virtualization technology, a physical network with core/aggregation
switches, access switches, and APs can be virtualized into a "super switch", simplifying network management.
⚫ CloudEngine S12700E series manages access switches in a similar way a WLAN AC manages APs, saving the trouble of
laborious configuration on access switches. It manages access switches and APs uniformly, allowing them to connect to the
network with zero configuration.
System Openness Capability
⚫ CloudEngine S12700E supports NETCONF/YANG through which users can perform automated configuration.
⚫ CloudEngine S12700E supports the Open Programmability System (OPS), an open programmable system based on the
Python language. IT administrators can program the O&M functions of CloudEngine S12700E through Python scripts to quickly
innovate functions and implement intelligent O&M.
Secure and Trustworthy System
⚫ Digital signatures of codes are used to identify software sources and the real identities of software developers to ensure
that code is not tampered with after being signed. To protect software, CloudEngine S12700E uses two levels of signature
mechanisms: inner signature and outer signature.
⚫ CloudEngine S12700E supports secure boot based on the hardware trust root. Starting from the trusted hardware anchor,
the software code to be loaded is checked level by level. This approach ensures that the MPUs, line cards, and SFUs are not
intruded since the boot phase.
⚫ The chipsets provide a secure Random Number Generator (RNG) module certified by NIST SP 800-90A and NIST SP 800-
90B to generate true secure random numbers for system running, thereby ensuring secure and trustworthy encryption.
Network-Level Reliability
⚫ CloudEngine S12700E uses link detection technologies such as hardware Eth-OAM and BFD, and adopts
standard/standards-compatible link switching technologies like G.8032 and Smart Ethernet Protection (SEP). These
technologies achieve end-to-end 50 ms hardware-level switchover and help build highly responsive campus network that
provides highly reliable services.
CloudEngine S12700E Series Switches Datasheet-V2R21C00 3
⚫ CloudEngine S12700E supports High-speed Self Recovery (HSR) technology that implements end-to-end IP MPLS
transmission network protection switchover within 50 ms, improving network reliability.
Easy Operation
CloudEngine S12700E supports EasyDeploy that implements plug-and-play for newly deployed devices and centrally manages
all devices running on the network. Typical Easy Deploy functions include the following:
⚫ Implementing Zero Touch Provisioning (ZTP) to automatically load the boot files such as version files, configuration files,
and patches
⚫ Upgrading network devices and delivering configurations in batches
⚫ Quickly replacing old devices with new ones that are plug-and-play without configuration
Intelligent Diagnosis
⚫ CloudEngine S12700E supports Open Intelligent Diagnosis System (OIDS). By integrating the device health monitoring
and fault diagnosis functions – that are typically deployed on a Network Management System (NMS) – into the switch
software, OIDS implements intelligent diagnosis on a single switch.
⚫ After OIDS is deployed on a switch, the switch periodically collects and records the running information and automatically
determines whether a fault occurs. If a fault occurs, the switch automatically locates the fault or helps locate the fault. All these
merits increase fault locating efficiency of O&M staff while improving device maintainability.
Solution Benifits
Simplified Management
⚫ Deployment automation: CloudEngine S12700E supports VXLAN and BGP-EVPN, and builds a Unified Virtual Fabric
(UVF) to automate deployment of up to 512 Virtual Networks (VNs). In this way, multiple service networks or tenant networks
can be deployed and isolated from each other on the same physical network, truly achieving one network for multiple purposes.
⚫ Policy automation: CloudEngine S12700E automates deployment of wired and wireless user policies on the entire network
and implements refined management and control based on SDN to achieve free mobility.
Intelligent O&M
⚫ CloudEngine S12700E provides telemetry technology to collect device data in real time and send the data to the
CampusInsight (a campus network analysis component of Huawei iMaster NCE). The CampusInsight then analyzes network
data based on the intelligent fault identification algorithm, accurately displays the real-time network status, effectively
demarcates and locates faults in a timely manner, and identifies network problems that affect user experience, accurately
guaranteeing user experiences.
⚫ CloudEngine S12700E supports a variety of intelligent O&M features for audio and video services, including the enhanced
Media Delivery Index (eMDI). With the eMDI function, the switch can function as a monitored node to periodically conduct
statistics and report audio and video service indicators to the CampusInsight. In this way, the CampusInsight can quickly
demarcate audio and video service quality faults based on the results of multiple monitored nodes.
Big Data Security Collaboration
⚫ CloudEngine S12700E can detect network security threats, display the security posture across the entire network, and
enable automated or manual response to security threats. The HiSec Insight delivers the security policies to the iMaster NCE-
Campus(or Agile Controller). The iMaster NCE-Campus(or Agile Controller) then delivers such policies to switches that will
handle security events accordingly. All these ensure campus network security.
Licensing
CloudEngine S12700E supports both the traditional feature-based licensing mode and the latest Huawei IDN One Software (N1
mode for short) licensing mode. The N1 mode is ideal for campus network deployments in enterprise private cloud mode, and
greatly enhances the customer experiences in purchasing and upgrading software services with simplicity.
CloudEngine S12700E Series Switches Datasheet-V2R21C00 4
Software Package Features in N1 Mode
Switch Functions N1 Basic N1 Foundation N1 Advanced
Software Software Software
Package Package
Basic network functions: √ √ √
Layer 2 functions, IPv4, IPv6, MPLS, SVF, and others
Note: For details, see the Functions and Features
Basic network automation based on the Agile × √ √
Controller:
⚫ Basic automation: Plug-and-play, SSID, and AP
group management
⚫ Basic monitoring: Application visualization
⚫ NE management: Image and topology
management and discovery
⚫ WLAN enhancement: Roaming and optimization
for up to 128 Aps
⚫ User access authentication
Advanced network automation and intelligent × × √
O&M:
VXLAN, free mobility, and CampusInsight basic
functions
Note: Only V200R019C00 and later versions can support N1 mode
Product Specifications
Functions and Features
Except for special instructions, the following features are supported by CloudEngine S12700E with N1 basic software.
Category Service Features CloudEngine S12700E
User management Unified user management Yes
PPPoE, 802.1X, MAC, and Portal authentication Yes
Traffic- and duration-based accounting Yes
User authorization based on user groups, domains, and time ranges Yes
MAC address Number of MAC address entries 1M(MAX)
Automatic MAC address learning and aging Yes
Static, dynamic, and blackhole MAC address entries Yes
Source MAC address filtering Yes
MAC address learning limiting based on ports and VLANs Yes
VLAN 4K VLANs Yes
Access, trunk, and hybrid interface types; auto-negotiation of LNP Yes
link types
Default VLAN Yes
CloudEngine S12700E Series Switches Datasheet-V2R21C00 5
Category Service Features CloudEngine S12700E
VLAN switching Yes
QinQ and enhanced selective QinQ Yes
Dynamic VLAN assignment based on MAC addresses Yes
ARP Maximum number of ARP entries 384K(MAX)
ARP Snooping √
IP routing Maximum number of IPv4 routing entries 3M(MAX)
Maximum number of IPv6 routing entries 1M(MAX)
IPv4 dynamic routing protocols such as RIP, OSPF, IS-IS, and BGP Yes
IPv6 dynamic routing protocols such as RIPng, OSPFv3, ISISv6, Yes
and BGP4+
Multicast Maximum number of multicast routing entries(IPv4) 64K(MAX)
Maximum number of multicast routing entries(IPv6) 64K(MAX)
IGMPv1/v2/v3 and IGMP v1/v2/v3 Snooping Yes
PIM-DM, PIM-SM, and PIM-SSM Yes
MSDP and MBGP Yes
Fast-leave mechanism Yes
Multicast traffic control Yes
Multicast querier Yes
Multicast protocol packet suppression Yes
Multicast Call Admission Control (CAC) Yes
Multicast ACL Yes
MPLS Basic MPLS functions Yes
MPLS OAM Yes
MPLS TE Yes
MPLS VPN/VLL/VPLS Yes
VXLAN VXLAN Layer 2 gateway Yes, require additional
license
VXLAN Layer 3 gateway Yes, require additional
license
Centralized gateway Yes, require additional
license
Distributed gateway Yes, require additional
license
BGP-EVPN Yes, require additional
license
Configures VXLANs through NETCONF Yes, require additional
license
CloudEngine S12700E Series Switches Datasheet-V2R21C00 6
Category Service Features CloudEngine S12700E
QoS Number of ACL rules(IPv4) 32K(MAX)
Number of ACL rules(IPv6) 16K(MAX)
Traffic classification based on Layer 2 headers, Layer 3 protocols, Yes
Layer 4 protocols, and 802.1p priority
Actions such as ACL, Committed Access Rate (CAR), re-marking, Yes
and scheduling
Queuing algorithms, such as PQ, WRR, DRR, PQ+WRR, and Yes
PQ+DRR
Congestion avoidance mechanisms such as WRED and tail drop Yes
HQoS Yes
Traffic shaping Yes
iPCA Marks the real service packets to obtain real-time count of dropped Yes
packets and packet loss ratio
Counts the number of dropped packets and packet loss ratio on Yes
devices and L2/L3 networks
SVF 2.0 Up to 10K clients (access switches and APs) virtualized into a single Yes
device
Two layers of ASs allowed in an SVF system Yes
Third-party devices allowed between SVF parent and clients Yes
Ring network STP (IEEE 802.1d), RSTP (IEEE 802.1w), and MSTP (IEEE Yes
protection 802.1s).
SEP Yes
BPDU protection, root protection, and loop protection Yes
BPDU tunnel Yes
G.8032 Ethernet Ring Protection Switching (ERPS) Yes
Reliability Link Aggregation Control Protocol (LACP) and E-Trunk Yes
Virtual Router Redundancy Protocol (VRRP) and Bidirectional Yes
Forwarding Detection (BFD) for VRRP
BFD for BGP/IS-IS/OSPF/static routes Yes
Non-Stop Forwarding (NSF) and Graceful Restart (GR) for BGP/IS- Yes
IS/OSPF/LDP
TE Fast ReRoute (FRR) and IP FRR Yes
Eth-OAM 802.3ah and 802.1ag (hardware-based) Yes
High-speed Self Recovery (HSR) Yes
ITU-Y.1731 Yes
Device Link Detection Protocol (DLDP) Yes
Smart Link Yes
Monitor Link Yes
CloudEngine S12700E Series Switches Datasheet-V2R21C00 7
Category Service Features CloudEngine S12700E
Configuration and Easy Operation Yes
maintenance
Terminal access services such as console port login, Telnet, and Yes
SSH
Network management protocols, such as SNMPv1/v2/v3 Yes
File uploading and downloading through FTP and TFTP Yes
BootROM upgrade and remote in-service upgrade Yes
Hot patches Yes
User operation logs Yes
Open Programmability System (OPS) Yes
Streaming Telemetry Yes
eMDI Yes
Security and MAC address, Portal, 802.1X, and DHCP snooping-triggered Yes
management authentication
MACsec Yes
NAC Yes
RADIUS and HWTACACS authentication for login users Yes
Command line authority control based on user levels, preventing Yes
unauthorized users from using command configurations
Defense against DoS attacks, Transmission Control Protocol (TCP) Yes
SYN Flood attacks, User Datagram Protocol (UDP) Flood attacks,
broadcast storms, and heavy traffic attacks
1K CPU hardware queues to implement hierarchical scheduling and Yes
protection for protocol packets on the control plane
Remote Network Monitoring (RMON) Yes
Secure boot (need to use MPU that supports secure boot) Yes
Big data security collaboration Yes
Wireless management Mesh networking Yes
(integrated WLAN AC):
N+N cold backup for devices with integrated WLAN AC functionality Yes
Basic WLAN services
Hot backup for devices with integrated WLAN AC functionality in Yes
cluster mode
WLAN terminal location Yes
Locating of interference sources Yes
Spectrum analysis function Yes
2.4G & 5G load balancing Yes
5G-prior access Yes
Wireless management Total number of managed APs 10K
(integrated WLAN AC):
An IPv4 network between an AP and a WLAN AC Yes
CloudEngine S12700E Series Switches Datasheet-V2R21C00 8
Category Service Features CloudEngine S12700E
AP management AP blacklist Yes
AP whitelist Yes
Sets the AP access control mode Yes
AP configuration and management Yes
AP energy saving Yes
AP LLDP topology awareness Yes
Adjustable priority of traffic on wired interfaces of APs Yes
Rate limiting on wired interfaces of APs Yes
Wireless management WLAN AP management* 10,240(MAX)
(integrated WLAN AC):
User roaming within a WLAN AC Yes
Wireless user
management AP-based user location Yes
User roaming between WLAN ACs Yes
802.1X authentication Yes
Portal authentication Yes
MAC address authentication Yes
Wireless management Direct data forwarding on L2/L3 networks Yes
(integrated WLAN AC):
Tunnel-based data forwarding on L2/L3 networks Yes
CAPWAP
Dual-link load balancing for CAPWAP tunnels Yes
CAPWAP tunnel encryption Yes
Wireless management 802.11a/b/g/n Yes
(integrated WLAN AC):
802.11ac wave1/wave2 Yes
RF management
802.11ax Yes
Sets RF interference monitoring and avoidance Yes
Detects co-channel interference, adjacent interference, and Yes
interference from other devices and STAs
Automatically selects channels and power when APs go online Yes
Dynamic power and channel optimization Yes
Wireless management Mapping from wireless-side priority to wired-side priority Yes
(integrated WLAN AC):
Mapping from wireless-side priority to CAPWAP channel priority Yes
WLAN QoS
Rate limiting of upstream and downstream traffic on the air interface Yes
based on the VAP
Rate limiting of upstream and downstream traffic on the air interface Yes
based on users
SSID-based CAR Yes
CAR for WLAN users Yes
Interoperability Interoperable with VBST (compatible with PVST/PVST+/RPVST) Yes
CloudEngine S12700E Series Switches Datasheet-V2R21C00 9
Category Service Features CloudEngine S12700E
Interoperable with LNP (similar to DTP) Yes
Interoperable with VCMP (similar to VTP) Yes
Note:The S12700E series switches can manage a maximum of 10,240 with MPUE, and 4,096 with MPUEC.
Hardware Specifications
Item CloudEngine S12700E-4 CloudEngine S12700E-8 CloudEngine S12700E-12
Switching capacity 19.2 Tbps 38.4 Tbps 57.6Tbps
Forwarding 14,400 Mpps 28,800 Mpps 43,200 Mpps
performance
MPU slots 2 2 2
SFU slots 2 4 4
LPU slots 4 8 12
Fan trays 2 4 5
Power 4 6 6
Buffering capacity Up to 200 ms data buffering Up to 200 ms data buffering Up to 200 ms data buffering per port
per port per port
Redundancy MPU, SFU, power module, MPU, SFU, power module, MPU, SFU, power module, and fan
design and fan module and fan module module
Virtualization CSS service port clustering CSS service port clustering CSS service port clustering
Dimensions (H x 441.7*442*517.4,10U 663.95*442*517.4, 15U 841.75*442*517.4, 19U
W x D)
Weight 24.5kg/66kg 42.5kg/114kg 71.8kg/184kg
(empty/fully Note Note Note
configured)
⚫ Empty configuration ⚫ Empty configuration ⚫ Empty configuration indicates that
indicates that the switch indicates that the switch the switch has no line card, MPU,
has no line card, MPU, or has no line card, MPU, or or power supply installed. Filler
power supply installed. power supply installed. panels are used, instead.
Filler panels are used, Filler panels are used, ⚫ Full configuration indicates that
instead. instead. the switch is fully configured with
⚫ Full configuration ⚫ Full configuration indicates MPUs, SFUs, line cards, and
indicates that the switch that the switch is fully power supplies. Their maximum
is fully configured with configured with MPUs, weights are used during
MPUs, SFUs, line cards, SFUs, line cards, and calculation.
and power supplies. power supplies. Their
Their maximum weights maximum weights are used
are used during during calculation.
calculation.
Operating voltage DC:–48V~–60V
AC:90V~290V
Maximum power 3344W 6950W 8981W
consumption
Operating ⚫ –60 m to +1800 m: 0°C to 45°C
temperature ⚫ 1800 m to 4000 m: The maximum operating temperature decreases by 1°C each time the altitude
CloudEngine S12700E Series Switches Datasheet-V2R21C00 10
Item CloudEngine S12700E-4 CloudEngine S12700E-8 CloudEngine S12700E-12
increases by 220 m.
⚫ 4000 m: 0°C to 35°C
Relative humidity 5% to 95% (non-condensing)
Heat dissipation Left-to-rear airflow, air-cooled heat dissipation, and intelligent fan speed adjustment
mode
Hardware Introduction
MPU
The Main Processing Unit (MPU) provides the control and management planes for the entire system. The control plane is mainly
responsible for protocol processing, service processing, route calculation, forwarding control, service scheduling, traffic statistics,
and system security. The management plane provides functions like monitoring the system running status, monitoring the
environment, processing logs and alarms, loading the system, and upgrading the system.
The following table lists the MPU supported by Huawei S12700E series switches.
Models and Appearance Description Supported Version
S12700E main processing unit E V200R019C00 and later versions
LST7MPUE0000
S12700E main processing unit E V200R020C10 and later versions
LST7MPUE0001
S12700E main processing unit EC V200R021C00SPC600 and later
versions
LST7MPUEC000
The following table lists the functions of MPUE.
Function Description
Basic functions The LST7MPUE0000/LST7MPUE0001 integrate the main control unit, clock unit, and system
maintenance unit.
OAM The LST7MPUE0000/LST7MPUE0001 support the following OAM functions:
⚫ 802.1ag: identifies, detects, and sends continuity check (CC) packets.
⚫ Multiprotocol Label Switching (MPLS OAM): identifies, detects, and sends MPLS OAM packets.
⚫ OAM UNCFG_MEP.
Memory 16 GB
Flash 64 MB/128 MB
NAND Flash 2 GB
The system configuration data, startup files, system software package, and system logs are saved
CloudEngine S12700E Series Switches Datasheet-V2R21C00 11
Function Description
in the NAND Flash by default.
Redundancy backup 1+1 hot standby
Main control board is mandatory for switches. Each switch must be configured with one or two main
control boards. When one main control board is configured for a switch, the main control board can
be installed in either main control board slot of the switch. When two main control boards are
configured, the two main control boards work in hot standby mode to improve reliability of the
switch. The active and standby main control boards monitor the status of each other. If the active
main control board fails, the standby main control board automatically becomes active to ensure
uninterrupted services.
Hot swapping Supported
Before removing the active card, perform an active/standby switchover.
Function Description
Basic functions The LST7MPUEC000 integrate the main control unit, and system maintenance unit.
OAM The LST7MPUEC000 supports the following OAM functions:
⚫ 802.1ag: identifies, detects, and sends continuity check (CC) packets.
⚫ Multiprotocol Label Switching (MPLS OAM): identifies, detects, and sends MPLS OAM packets.
⚫ OAM UNCFG_MEP.
Memory 8 GB
Flash 64 MB/128 MB
NAND Flash 2 GB
The system configuration data, startup files, system software package, and system logs are saved
in the NAND Flash by default.
Redundancy backup 1+1 hot standby
Main control board is mandatory for switches. Each switch must be configured with one or two main
control boards. When one main control board is configured for a switch, the main control board can
be installed in either main control board slot of the switch. When two main control boards are
configured, the two main control boards work in hot standby mode to improve reliability of the
switch. The active and standby main control boards monitor the status of each other. If the active
main control board fails, the standby main control board automatically becomes active to ensure
uninterrupted services.
Hot swapping Supported
Before removing the active card, perform an active/standby switchover.
SFU
The Switch Fabric Unit (SFU) provides the data plane for the entire system. The data plane provides high-speed and non-
blocking data channels for service switching between service modules.
The following table lists the SFU supported by Huawei S12700E series switches.
Models and Appearance Description Supported Version
S12700E Switch Fabric Unit E (X1) V200R019C00 and later versions,
only used in S12700E-4 and
S12700E-8
LST7SFUEX100
CloudEngine S12700E Series Switches Datasheet-V2R21C00 12
Models and Appearance Description Supported Version
S12700E Switch Fabric Unit H (X1) V200R019C00 and later versions,
only used in S12700E-4 and
S12700E-8
LST7SFUHX100
S12700E Switch Fabric Unit M (X1) V200R019C00 and later versions,
only used in S12700E-12
LST7SFUMX100
The following table lists the functions of SFUE/SFUH/SFUM.
Function SFUE SFUH SFUM
Basic function Core of data switching Core of data switching Core of data switching
Memory 1 GB 2 GB 2 GB
Flash 128 MB 128 MB 128 MB
Redundancy backup N+1 hot standby N+1 hot standby N+1 hot standby
Hot swapping Supported Supported Supported
SFU cards in a chassis can work in redundancy mode to improve system reliability. If one SFU fails, service traffic on this card
will be switched to other SFUs to ensure uninterrupted services
CMU
The Centralized Monitoring Unit(CMU) manages power modules and fan modules in a chassis. The CMU is hot swappable. Two
CMU cards can be installed in a chassis to work in active/standby mode.
The following table lists the CMU supported by Huawei S12700E series switches.
Models and Appearance Description Supported Version
Centralized Monitoring Unit V200R019C00 and later versions
EH1D200CMU00
The following table lists the functions of CMU.
Function Description
Fan module ⚫ Fan module presence detection
management ⚫ Fan module registration management
⚫ Fan speed monitoring
⚫ Fan speed control
⚫ Management and report of fan module alarms
⚫ Query of fan module electronic labels
Power module ⚫ Power module presence detection
CloudEngine S12700E Series Switches Datasheet-V2R21C00 13
Function Description
management ⚫ Power module shutdown
⚫ Power module registration management
⚫ Voltage and current monitoring
⚫ Management and report of power module alarms
⚫ Query of power module electronic labels
Interface Card
An interface card, or called LPU, processes all traffic on the network data plane of a switch. The S12700E supports a broad set
of interface cards that offer varying numbers of 100GE, 40GE, 25GE, 10GE, and GE ports. Customers can flexibly select them
as required.
Card Name Description Supported Version
LST7G48TX5E1 48-port 10/100/1000BASE-T interface card (X5E, RJ45) V200R019C00 and later versions
LST7G48TX5S1 48-port 10/100/1000BASE-T interface card (X5S, RJ45) V200R019C00 and later versions
LST7G48SX6E0 48-port 1000M Ethernet optical interface card (X6E, SFP) V200R019C00 and later versions
LST7G48SX6S0 48-port 1000M Ethernet optical interface card (X6S, SFP) V200R019C00 and later versions
LST7X24BX6E0 24-port 10GBASE-X and 24-port 1000BASE-X interface card V200R019C00 and later versions
(X6E, SFP+)
LST7X24BX6S0 24-port 10GBASE-X and 24-port 1000BASE-X interface card V200R019C00 and later versions
(X6S, SFP+)
LST7X48SX6E0 48-port 10GBASE-X interface card (X6E, SFP+) V200R019C00 and later versions
LST7X48SX6S0 48-port 10GBASE-X interface card (X6S, SFP+) V200R019C00 and later versions
LST7Y40SX6H0 40-port 25GE SFP28 interface card (X6H,SFP28) V200R019C10 and later versions
LST7C06HX6E0 6-port 100GE QSFP28 interface card (X6E, QSFP28) V200R019C00 and later versions
LST7C06HX6S0 6-port 100GE QSFP28 interface card (X6S, QSFP28) V200R019C00 and later versions
LST7C24HX6E0 24-Port 100GE QSFP28 Interface Card (X6E, QSFP28) V200R019C00 and later versions
LST7G48TX6S0 48-port 100/1000BASE-T interface card (X6S,RJ45) V200R021C00 and later versions
LST7G48TX6E0 48-port 100/1000BASE-T interface card (X6E,RJ45) V200R021C00 and later versions
LST7M24BX6E0 24-port 100M/1G/2.5G/5G/10G and 24-port 100M/1G interface V200R021C00 and later versions
card (X6E,RJ45)
LST7L12QX6E0 12-port 40GE QSFP+ inferface card (X6E,QSFP+) V200R021C00 and later versions
Power Module
Power Module Backup Modes
The S12700E power modules support the backup mode. Three power module configuration modes are recommended: N+N
backup, N+1 backup, and N+0 without backup. The value of N is determined by the maximum power required by the system. N
multiplied by the maximum output power of each power module must be larger than the maximum power required by the system.
The system can automatically identify the backup mode, without the need of manual configuration through CLIs.
Assume that the maximum power required by the system is 4,000 W. If two 2,200 W power modules are installed, the backup
mode is 2+0 without backup. If three 2,200 W power modules are installed, the backup mode is 2+1 backup. If four 2,200 W
power modules are installed, the backup mode is 2+2 backup.
CloudEngine S12700E Series Switches Datasheet-V2R21C00 14
The S12700E supports 2,200 W DC and 3,000 W AC power modules. The following table lists the maximum output power of the
entire system in different backup modes.
Models and Backup Maximum Output Maximum Output Maximum Output
Appearance Mode Power of the Power of the S12700E-8 Power of the S12700E-8
S12700E-4
N+N backup A maximum of four (2+2) A maximum of six (3+3) A maximum of six (3+3) 2,200
2,200 W DC power 2,200 W DC power modules W DC power modules can be
modules can be can be configured, providing configured, providing the
configured, providing the the maximum power supply maximum power supply
maximum power supply capability of 6,600W. capability of 6,600W.
capability of 4,400 W.
W2PSD2200 N+1 backup A maximum of four (3+1) A maximum of six (5+1) A maximum of six (5+1) 2,200
2,200 W DC power 2,200 W DC power modules W DC power modules can be
modules can be can be configured, providing configured, providing the
configured, providing the the maximum power supply maximum power supply
maximum power supply capability of 11,000 W. capability of 11,000 W.
capability of 6,600 W.
N+0 without A maximum of four (4+0) A maximum of six (6+0) A maximum of six (6+0)
backup 2,200 W DC power 2,200W DC power modules 2,200W DC power modules
modules can be can be configured, providing can be configured, providing
configured, providing the the maximum power supply the maximum power supply
maximum power supply capability of 12,000 W. capability of 13,200 W.
capability of 8,800 W.
N+N backup A maximum of four (2+2) A maximum of six (3+3) A maximum of six (3+3) 3,000
3,000 W AC power 3,000 W AC power modules W AC power modules can be
modules can be can be configured, providing configured, providing the
configured, providing the the maximum power supply maximum power supply
maximum power supply capability of 9,000 W. capability of 9,000 W.
PAC3KS54- capability of 6,000 W.
CE
N+1 backup A maximum of four (3+1) A maximum of six (5+1) A maximum of six (5+1) 3,000
PAC3KS54- 3,000 W AC power 3,000 W AC power modules W AC power modules can be
NE modules can be can be configured, providing configured, providing the
configured, providing the the maximum power supply maximum power supply
maximum power supply capability of 12,000 W. capability of 14,000 W.
capability of 9,000 W.
N+0 without A maximum of four (4+0) A maximum of six (6+0) A maximum of six (6+0) 3,000
backup 3,000 W AC power 3,000 W AC power modules W AC power modules can be
modules can be can be configured, providing configured, providing the
configured, providing the the maximum power supply maximum power supply
maximum power supply capability of 12,000 W. capability of 14,000 W.
capability of 9,000 W.
Power Module Specifications
The following table lists the specifications of each power module.
Parameter W2PSD2200(DC Power Module) PAC3KS54-CE(AC Power Module)
Dimensions (H x W x D) 41 mm × 393 mm × 130 mm 41 mm × 417.4 mm × 130 mm
Weight < 2.5 kg < 3.0 kg
AC input Rated input -48 V DC/-60 V DC 220 V AC/110 V AC; 50/60 Hz
voltage
Rated input -40 V DC to -72 V DC 200 V AC to 240 V AC (rated input voltage:
CloudEngine S12700E Series Switches Datasheet-V2R21C00 15
Parameter W2PSD2200(DC Power Module) PAC3KS54-CE(AC Power Module)
voltage range 220 V AC)/100 V AC to 130 V AC (rated
input voltage: 110 V AC); 47 Hz to 63 Hz
Maximum input -40 V DC to -72 V DC 90 V AC to 290 V AC; 47 Hz to 63 Hz
voltage range (When the input voltage range is 90 V AC
to 175 V AC, the maximum output power of
the power module is reduced by half.)
The maximum current of the power cable
used by the 3,000 W AC power module is
16 A. When the 220 V input is used, the
minimum voltage cannot be lower than 200
V. When the 110 V input is used, the
minimum voltage cannot be lower than 100
V.
Maximum input 60 A 16 A
current
High-voltage DC Rated input - 240 V DC
input voltage
Maximum input - 190 V DC to 290 V DC
voltage range
Maximum input - 14 A
current
Output Maximum output 42 A 56.1 A (rated input voltage: 220 V AC)/28.1
current A (rated input voltage: 110 V AC)
Maximum output 2,200 W 3,000 W (rated input voltage: 220 V AC or
power 240 V DC)/1,500 W (rated input voltage:
110 V AC)
Hot swap Supported Supported
Environment parameters ⚫ Operating temperature: 0°C to 45°C ⚫ Operating temperature: 0°C to 45°C
⚫ Operating relative humidity: 5%RH ⚫ Operating relative humidity: 5%RH to
to 95%RH, non-condensing 95%RH, non-condensing
⚫ Storage temperature: -40°C to ⚫ Storage temperature: -40°C to +70°C
+70°C ⚫ Storage relative humidity: 5%RH to
⚫ Storage relative humidity: 5%RH to 95%RH, non-condensing
95%RH, non-condensing
Fan Module
Each fan module has two fans and can work for a short time when one fan fails. When any fan in a fan module fails, handle the
failure immediately to ensure that the fan module can work normally.
The following table lists the fan module supported by Huawei S12700E series switches.
Models and Appearance Description Supported Version
FAN-770A-B fan box V200R019C00 and later versions
FAN-770A-B
CloudEngine S12700E Series Switches Datasheet-V2R21C00 16
Fan Module Functions
Function Description Supported Version
Hot swapping Supported V200R019C00 and later versions
Other fan modules are not affected when you install or remove a
fan module.
Intelligent fan speed The S12700E series switches provide intelligent fan speed V200R019C00 and later versions
adjustment adjustment based on temperature in each zone, and correlate
speeds of fans in the entire chassis. The system monitors the
temperature of key components, and adjusts the fan speed based
on temperature changes. This intelligent fan speed adjustment
function ensures that the system stays within the proper operating
temperature range, and reduces power consumption and noise.
Fan Module Specifications
Function Description Supported Version
Dimensions (H x W 126.6 mm x 323.9 mm x 65 mm (5.0 in. x 12.8 in. x 2.6 in.) V200R019C00 and later versions
x D)
Number of fans 2 V200R019C00 and later versions
Weight 2.5 kg (5.51 lb) V200R019C00 and later versions
Maximum power 395 W V200R019C00 and later versions
consumption
Operating voltage -30 V DC to -73 V DC V200R019C00 and later versions
range
Environment ⚫ Operating temperature: 0°C to 45°C (32°F to 113°F) V200R019C00 and later versions
specifications ⚫ Operating relative humidity: 5% RH to 95% RH
(noncondensing)
⚫ Storage temperature: -40°C to +70°C (-40°F to +158°F)
⚫ Storage relative humidity: 5% RH to 95% RH
(noncondensing)
Networking and Applications
In a Campus Network
CloudEngine S12700E series switches are deployed on the core layer of an enterprise campus network. ACs are built in to the
switches to achieve the following purposes:
⚫ Wireless networks can be constructed without any additional AC devices, reducing network construction costs.
⚫ With the wired and wireless convergence capability, they can deliver a consistent experience to wired and wireless users
through uniform device management, user management, and service management.
⚫ The T-bit AC capability avoids performance bottlenecks on independent ACs and enables a migration to 802.11ax networks.
In a MAN
CloudEngine S12700E series switches can be used as core or aggregation switches on a metro television broadcasting.
⚫ Providing millions of FIB entries for large-scale routing on the network.
⚫ Supporting comprehensive L2/L3 MPLS VPN features, ensuring high reliability, security, and scalability on the metropolitan
bearer network.
CloudEngine S12700E Series Switches Datasheet-V2R21C00 17
⚫ Single-link 100G hardware clustering technology delivers carrier-grade reliability.
In a Data Center
CloudEngine S12700E series switches can be deployed on the core or aggregation layer of an enterprise data center network
⚫ Providing large throughput using high-density line cards, such as 24*100GE,6*100GE,40*25GE and 48*10GE/GE
cards.
⚫ CloudEngine S12700E series switches support single-link 100G hardware clustering. This technology helps to build a data
center network with high performance, high reliability, and low latency.
In an Education Campus Network
CloudEngine S12700E series switches are deployed on the core layer of a college campus network.
⚫ Allowing for a large number of concurrent access users.
⚫ As they support unified user management, you do not need to buy additional hardware components, reducing network
construction costs.
⚫ The H-QoS feature implements fine granular user and service management.
⚫ With the wired and wireless convergence capability, they can deliver a consistent experience to wired and wireless users
through uniform device management, user management, and service management.
In a Bearer Network for Video Conferencing and Desktop Cloud Applications
⚫ CloudEngine S12700E series switches have a large buffer to prevent packet loss when traffic bursts occur, delivering high-
quality video streams.
⚫ CloudEngine S12700E series switches support millions of hardware entries, which allow for a large number of terminals
and facilitate evolution to IPv6 and the Internet of Things.
⚫ Employing end-to-end hardware reliability technologies and iPCA, CloudEngine S12700E series switches offer a highly
reliable, high-quality, scalable video conferencing.
Safety and Regulatory Compliance
The following table lists the safety and regulatory compliance of CloudEngine S12700E.
Safety and regulatory compliance of CloudEngine S12700E series
Certification Category Specification
Safety ⚫ IEC 60950-1
⚫ EN 60950-1
⚫ UL 60950-1
⚫ CSA C22.2 No 60950-1
⚫ AS/NZS 60950.1
⚫ BS EN 60950-1
⚫ CNS 14336-1
Electromagnetic ⚫ CISPR22 Class A
Compatibility (EMC) ⚫ CISPR24
⚫ EN55022 Class A
⚫ EN55024
⚫ ETSI EN 300 386 Class A
⚫ CFR 47 FCC Part 15 Class A
⚫ ICES 003 Class A
CloudEngine S12700E Series Switches Datasheet-V2R21C00 18
Certification Category Specification
⚫ AS/NZS CISPR22 Class A
⚫ VCCI Class A
⚫ IEC61000-6-2
⚫ IEC61000-6-4
⚫ IEC61000-4-2
⚫ ITU-T K 20
⚫ ITU-T K 21
⚫ ITU-T K 44
⚫ CNS13438
Environment ⚫ RoHS
⚫ REACH
⚫ WEEE
Laser safety ⚫ IEC60825-1
⚫ IEC60825-2
⚫ EN60825-1
⚫ EN60825-2
⚫ EMC: electromagnetic compatibility
⚫ CISPR: International Special Committee on Radio Interference
⚫ EN: European Standard
⚫ ETSI: European Telecommunications Standards Institute
⚫ CFR: Code of Federal Regulations
⚫ FCC: Federal Communication Commission
⚫ IEC: International Electrotechnical Commission
⚫ AS/NZS: Australian/New Zealand Standard
⚫ VCCI: Voluntary Control Council for Interference
⚫ UL: Underwriters Laboratories
⚫ CSA: Canadian Standards Association
⚫ IEEE: Institute of Electrical and Electronics Engineers
⚫ RoHS: restriction of the use of certain hazardous substances
⚫ REACH: Registration Evaluation Authorization and Restriction of Chemicals
⚫ WEEE: Waste Electrical and Electronic Equipment
MIB and Standards Compliance
Supported MIBs
The following table lists the MIBs supported by CloudEngine S12700E series.
MIBs supported by the S12700E series
Category Specification
Public MIB ⚫ BGP4-MIB
⚫ BRIDGE-MIB
⚫ DISMAN-NSLOOKUP-MIB
⚫ DISMAN-PING-MIB
CloudEngine S12700E Series Switches Datasheet-V2R21C00 19
Category Specification
⚫ DISMAN-TRACEROUTE-MIB
⚫ ENTITY-MIB
⚫ EtherLike-MIB
⚫ IF-MIB
⚫ IP-FORWARD-MIB
⚫ IPMCAST-MIB
⚫ IPv6-ICMP-MIB
⚫ IPv6-MIB
⚫ IPv6-TCP-MIB
⚫ IPv6-UDP-MIB
⚫ ISIS-MIB
⚫ LAG-MIB
⚫ LLDP-EXT-DOT1-MIB
⚫ LLDP-EXT-DOT3-MIB
⚫ LLDP-MIB
⚫ MGMD-STD-MIB
⚫ MPLS-FTN-STD-MIB
⚫ MPLS-L3VPN-STD-MIB
⚫ MPLS-LDP-GENERIC-STD-MIB
⚫ MPLS-LDP-STD-MIB
⚫ MPLS-LSR-STD-MIB
⚫ MPLS-TE-STD-MIB
⚫ MSDP-MIB
⚫ NOTIFICATION-LOG-MIB
⚫ NQA-MIB
⚫ OSPF-MIB
⚫ OSPF-TRAP-MIB
⚫ P-BRIDGE-MIB
⚫ PIM-BSR-MIB
⚫ PIM-STD-MIB
⚫ Q-BRIDGE-MIB
⚫ RFC1213-MIB
⚫ RIPv2-MIB
⚫ RMON2-MIB
⚫ RMON-MIB
⚫ SAVI-MIB
⚫ SNMP-FRAMEWORK-MIB
⚫ SNMP-MPD-MIB
⚫ SNMP-NOTIFICATION-MIB
⚫ SNMP-TARGET-MIB
⚫ SNMP-USER-BASED-SM-MIB
⚫ SNMPv2-MIB
⚫ SNMP-VIEW-BASED-ACM-MIB
⚫ TCP-MIB
⚫ UDP-MIB
CloudEngine S12700E Series Switches Datasheet-V2R21C00 20
Category Specification
⚫ VRRP-MIB
⚫ VRRPv3-MIB
Huawei-proprietary MIB ⚫ HUAWEI-AAA-MIB
⚫ HUAWEI-ACL-MIB
⚫ HUAWEI-ALARM-MIB
⚫ HUAWEI-ALARM-RELIABILITY-MIB
⚫ HUAWEI-BASE-TRAP-MIB
⚫ HUAWEI-BFD-MIB
⚫ HUAWEI-BGP-VPN-MIB
⚫ HUAWEI-BRAS-RADIUS-MIB
⚫ HUAWEI-BRAS-SRVCFG-EAP-MIB
⚫ HUAWEI-BRAS-SRVCFG-STATICUSER-MIB
⚫ HUAWEI-BULKSTAT-MIB
⚫ HUAWEI-CBQOS-MIB
⚫ HUAWEI-CCC-MIB
⚫ HUAWEI-CONFIG-MAN-MIB
⚫ HUAWEI-CLOCK-MIB
⚫ HUAWEI-CPU-MIB
⚫ HUAWEI-DAD-MIB
⚫ HUAWEI-DC-TRAP-MIB
⚫ HUAWEI-DATASYNC-MIB
⚫ HUAWEI-DEVICE-MIB
⚫ HUAWEI-DHCPR-MIB
⚫ HUAWEI-DHCPS-MIB
⚫ HUAWEI-DHCP-SNOOPING-MIB
⚫ HUAWEI-DIE-MIB
⚫ HUAWEI-DNS-MIB
⚫ HUAWEI-DLDP-MIB
⚫ HUAWEI-ERPS-MIB
⚫ HUAWEI-ERRORDOWN-MIB
⚫ HUAWEI-ENERGYMNGT-MIB
⚫ HUAWEI-EASY-OPERATION-MIB
⚫ HUAWEI-ENTITY-EXTENT-MIB
⚫ HUAWEI-ENTITY-TRAP-MIB
⚫ HUAWEI-ETHARP-MIB
⚫ HUAWEI-ETHOAM-MIB
⚫ HUAWEI-E-TRUNK-MIB
⚫ HUAWEI-FLASH-MAN-MIB
⚫ HUAWEI-FTP-MIB
⚫ HUAWEI-FWD-RES-TRAP-MIB
⚫ HUAWEI-GARP-APP-MIB
⚫ HUAWEI-GTL-MIB
⚫ HUAWEI-GTSM-MIB
⚫ HUAWEI-HGMP-MIB
CloudEngine S12700E Series Switches Datasheet-V2R21C00 21
Category Specification
⚫ HUAWEI-HQOS-MIB
⚫ HUAWEI-HWTACACS-MIB
⚫ HUAWEI-IF-EXT-MIB
⚫ HUAWEI-INFOCENTER-MIB
⚫ HUAWEI-IPFPM-MIB
⚫ HUAWEI-IPLPM-MIB
⚫ HUAWEI-IPMCAST-MIB
⚫ HUAWEI-IPPOOL-MIB
⚫ HUAWEI-IPSESSION-MIB
⚫ HUAWEI-IPV6-MIB
⚫ HUAWEI-ISOLATE-MIB
⚫ HUAWEI-KOMPELLA-MIB
⚫ HUAWEI-L2IF-MIB
⚫ HUAWEI-L2MAM-MIB
⚫ HUAWEI-L2MULTICAST-MIB
⚫ HUAWEI-L2VLAN-MIB
⚫ HUAWEI-L2VPN-MIB
⚫ HUAWEI-LDT-MIB
⚫ HUAWEI-LSP-PING-TRACE-TRAP-MIB
⚫ HUAWEI-LINE-MIB
⚫ HUAWEI-LLDP-MIB
⚫ HUAWEI-MAC-AUTHEN-MIB
⚫ HUAWEI-MDNS-RELAY-MIB
⚫ HUAWEI-MEMORY-MIB
⚫ HUAWEI-MFF-MIB
⚫ HUAWEI-MFLP-MIB
⚫ HUAWEI-MGMD-STD-MIB
⚫ HUAWEI-MPLS-EXTEND-MIB
⚫ HUAWEI-MPLSLDP-MIB
⚫ HUAWEI-MPLSLSR-EXT-MIB
⚫ HUAWEI-MPLSOAM-MIB
⚫ HUAWEI-MSDP-MIB
⚫ HUAWEI-MSTP-MIB
⚫ HUAWEI-MULTICAST-MIB
⚫ HUAWEI-NETSTREAM-MIB
⚫ HUAWEI-NTPV3-MIB
⚫ HUAWEI-OSPFV2-MIB
⚫ HUAWEI-OSPFV3-MIB
⚫ HUAWEI-PERFORMANCE-MIB
⚫ HUAWEI-PIM-BSR-MIB
⚫ HUAWEI-PIM-STD-MIB
⚫ HUAWEI-PERFMGMT-MIB
⚫ HUAWEI-PORT-MIB
⚫ HUAWEI-PORTAL-MIB
⚫ HUAWEI-PWE3-MIB
CloudEngine S12700E Series Switches Datasheet-V2R21C00 22
Category Specification
⚫ HUAWEI-PWE3-TNL-MIB
⚫ HUAWEI-QINQ-MIB
⚫ HUAWEI-RIPv2-EXT-MIB
⚫ HUAWEI-RM-EXT-MIB
⚫ HUAWEI-RRPP-MIB
⚫ HUAWEI-RSVPTE-MIB
⚫ HUAWEI-SECURITY-MIB
⚫ HUAWEI-SEP-MIB
⚫ HUAWEI-SMARTLINK-MIB
⚫ HUAWEI-SNMP-EXT-MIB
⚫ HUAWEI-SSH-MIB
⚫ HUAWEI-STACK-MIB
⚫ HUAWEI-SWITCH-L2MAM-EXT-MIB
⚫ HUAWEI-SWITCH-SRV-TRAP-MIB
⚫ HUAWEI-SYS-MAN-MIB
⚫ HUAWEI-TASK-MIB
⚫ HUAWEI-TCP-MIB
⚫ HUAWEI-TFTPC-MIB
⚫ HUAWEI-TRNG-MIB
⚫ HUAWEI-TUNNEL-MIB
⚫ HUAWEI-TUNNEL-TE-MIB
⚫ HUAWEI-UNIMNG-MIB
⚫ HUAWEI-USC-MIB
⚫ HUAWEI-VPLS-EXT-MIB
⚫ HUAWEI-VPLS-TNL-MIB
⚫ HUAWEI-VPN-DIAGNOSTICS-MIB
⚫ HUAWEI-VRRP-EXT-MIB
⚫ HUAWEI-WLAN-DEVICE-MIB
⚫ HUAWEI-WLAN-QOS-MIBB
⚫ HUAWEI-WLAN-RADIO-MIB
⚫ HUAWEI-WLAN-SECURITY-MIB
⚫ HUAWEI-WLAN-SERVICE-MIB
⚫ HUAWEI-WLAN-SYS-MIB
⚫ HUAWEI-WLAN-UPDATE-MIB
⚫ HUAWEI-WLAN-WIDS-MIB
⚫ HUAWEI-XQOS-MIB
For more information about MIBs supported by CloudEngine S12700E series, visit
https://support.huawei.com/enterprise/en/switches/s12700e-pid-250450822
Standard Compliance
The following table lists the standards that CloudEngine S12700E complies with.
CloudEngine S12700E Series Switches Datasheet-V2R21C00 23
Standard compliance list of CloudEngine S12700E series
Standard Standard or Protocol
Organization
IETF ⚫ RFC 768 User Datagram Protocol (UDP)
⚫ RFC 792 Internet Control Message Protocol (ICMP)
⚫ RFC 793 Transmission Control Protocol (TCP)
⚫ RFC 826 Ethernet Address Resolution Protocol (ARP)
⚫ RFC 854 Telnet Protocol Specification
⚫ RFC 951 Bootstrap Protocol (BOOTP)
⚫ RFC 959 File Transfer Protocol (FTP)
⚫ RFC 1058 Routing Information Protocol (RIP)
⚫ RFC 1112 Host extensions for IP multicasting
⚫ RFC 1157 A Simple Network Management Protocol (SNMP)
⚫ RFC 1256 ICMP Router Discovery
⚫ RFC 1305 Network Time Protocol Version 3 (NTP)
⚫ RFC 1349 Internet Protocol (IP)
⚫ RFC 1493 Definitions of Managed Objects for Bridges
⚫ RFC 1542 Clarifications and Extensions for the Bootstrap Protocol
⚫ RFC 1643 Ethernet Interface MIB
⚫ RFC 1757 Remote Network Monitoring (RMON)
⚫ RFC 1901 Introduction to Community-based SNMPv2
⚫ RFC 1902-1907 SNMP v2
⚫ RFC 1981 Path MTU Discovery for IP version 6
⚫ RFC 2131 Dynamic Host Configuration Protocol (DHCP)
⚫ RFC 2328 OSPF Version 2
⚫ RFC 2453 RIP Version 2
⚫ RFC 2460 Internet Protocol, Version 6 Specification (IPv6)
⚫ RFC 2461 Neighbor Discovery for IP Version 6 (IPv6)
⚫ RFC 2462 IPv6 Stateless Address Auto configuration
⚫ RFC 2463 Internet Control Message Protocol for IPv6 (ICMPv6)
⚫ RFC 2474 Differentiated Services Field (DS Field)
⚫ RFC 2740 OSPF for IPv6 (OSPFv3)
⚫ RFC 2863 The Interfaces Group MIB
⚫ RFC 2597 Assured Forwarding PHB Group
⚫ RFC 2598 An Expedited Forwarding PHB
⚫ RFC 2571 SNMP Management Frameworks
⚫ RFC 2865 Remote Authentication Dial In User Service (RADIUS)
⚫ RFC 3046 DHCP Option82
⚫ RFC 3376 Internet Group Management Protocol, Version 3 (IGMPv3)
⚫ RFC 3513 IP Version 6 Addressing Architecture
⚫ RFC 3579 RADIUS Support For EAP
⚫ RFC 4271 A Border Gateway Protocol 4 (BGP-4)
⚫ RFC 4760 Multiprotocol Extensions for BGP-4
⚫ RFC 5798 Virtual Router Redundancy Protocol (VRRP) Version 3 for IPv4 and IPv6
⚫ draft-grant-tacacs-02 TACACS+
CloudEngine S12700E Series Switches Datasheet-V2R21C00 24
Standard Standard or Protocol
Organization
IEEE ⚫ IEEE 802.1D Media Access Control (MAC) Bridges
⚫ IEEE 802.1p Virtual Bridged Local Area Networks
⚫ IEEE 802.1Q Virtual Bridged Local Area Networks
⚫ IEEE 802.1ad Provider Bridges
⚫ IEEE 802.2 Logical Link Control
⚫ IEEE Std 802.3 CSMA/CD
⚫ IEEE Std 802.3ab 1000BASE-T specification
⚫ IEEE Std 802.3ad Aggregation of Multiple Link Segments
⚫ IEEE Std 802.3ae 10GE WEN/LAN Standard
⚫ IEEE Std 802.3x Full Duplex and flow control
⚫ IEEE Std 802.3z Gigabit Ethernet Standard
⚫ IEEE802.1ax/IEEE802.3ad Link Aggregation
⚫ IEEE 802.3ah Ethernet in the First Mile.
⚫ IEEE 802.1ag Connectivity Fault Management
⚫ IEEE 802.1ab Link Layer Discovery Protocol
⚫ IEEE 802.1D Spanning Tree Protocol
⚫ IEEE 802.1w Rapid Spanning Tree Protocol
⚫ IEEE 802.1sMultiple Spanning Tree Protocol
⚫ IEEE802.1x Port based network access control protocol
ITU ⚫ ITU SG13 Y.17ethoam
⚫ ITU SG13 QoS control Ethernet-Based IP Access
⚫ ITU-T Y.1730 ETH OAM performance monitor
⚫ ITU-T Y.1731 ETH OAM performance monitor
⚫ ITU-T Y.1710 Requirements for OAM functionality for MPLS networks
⚫ ITU-T Y.1711 Operation and maintenance mechanism for MPLS networks
⚫ ITU-T Y.1720 Protection switching for MPLS networks
ISO ⚫ ISO 10589IS-IS Routing Protocol
MEF ⚫ MEF 2 Requirements and Framework for Ethernet Service Protection
⚫ MEF 9 Abstract Test Suite for Ethernet Services at the UNI
⚫ MEF 10.2 Ethernet Services Attributes Phase 2
⚫ MEF 11 UNI Requirements and Framework
⚫ MEF 13 UNI Type 1 Implementation Agreement
⚫ MEF 15 Requirements for Management of Metro Ethernet Phase 1 Network Elements
⚫ MEF 17 Service OAM Framework and Requirements
⚫ MEF 20 UNI Type 2 Implementation Agreement
⚫ MEF 23 Class of Service Phase 1 Implementation Agreement
Ordering Information
S12700E Basic Configuration
LE2BN66ED000 N66E DC assembly cabinet (eight 60A outputs, maximum 2200W, 600 × 600 × 2200 mm)
CloudEngine S12700E Series Switches Datasheet-V2R21C00 25
S12700E Basic Configuration
LE2BN66EA000 N66E AC assembly cabinet (four 16 A outputs, a maximum of 2500W, 600 × 600 × 2200 mm)
ET1BS12704E0 S12700E-4 assembly chassis
ET1BS12708E0 S12700E-8 assembly chassis
ET1BS12712E1 S12700E-12 assembly chassis
FAN-770A-B Fan box (-5degC–55degC, 48V, 400W, 2, indoors, VA)
Main Processing Unit
LST7MPUE0000 S12700E Main Processing Unit E
LST7MPUE0001 S12700E Main Processing Unit E
Monitoring Unit
EH1D200CMU00 Centralized Monitoring Unit
Switch Fabric Unit
LST7SFUEX100 S12700E Switch Fabric Unit E(X1)
LST7SFUHX100 S12700E Switch Fabric Unit H (X1)
LST7SFUMX100 S12700E Switch Fabric Unit M (X1)
100GE Ethernet optical interface card
LST7C06HX6E0 6-port 100GE QSFP28 interface card (X6E,QSFP28)
LST7C06HX6S0 6-port 100GE QSFP28 interface card (X6S,QSFP28)
LST7C24HX6E0 24-port 100GE QSFP28 interface card (X6E,QSFP28)
40GE/100GE Ethernet optical interface card
LST7C02BX6E0 2-port 100GE QSFP28 interface and 4-port 40GE QSFP28 interface card V200R020C00 and
(X6E,QSFP28) later versions
40GE Ethernet optical interface card
LST7L12QX6E0 12-port 40GE QSFP+ inferface card (X6E,QSFP+) V200R021C00 and
later versions
25GE optical interface card
CloudEngine S12700E Series Switches Datasheet-V2R21C00 26
25GE optical interface card
LST7Y40SX6H0 40-port 25GE SFP28 interface card (X6H,SFP28)
10GE/1000M Ethernet optical interface card
LST7X24BX6E0 24-port 10GE SFP+ interface and 24-port GE SFP interface card (X6E,SFP+)
LST7X24BX6S0 24-port 10GE SFP+ interface and 24-port GE SFP interface card (X6S,SFP+)
MultiGE interface card
LST7M24BX6E0 24-port 100M/1G/2.5G/5G/10G and 24-port 100M/1G interface card V200R021C00 and
(X6E,RJ45) later versions
Gigabit Ethernet optical interface card
LST7G48SX6E0 48-port GE SFP interface card (X6E,SFP)
LST7G48SX6S0 48-port GE SFP interface card (X6S,SFP)
Gigabit Ethernet electrical interface card
LST7G48TX5E1 48-port 10/100/1000BASE-T interface card (X5E,RJ45)
LST7G48TX5S1 48-port 10/100/1000BASE-T Interface Card (X5S, RJ45)
LST7G48TX6S0 48-port 100/1000BASE-T interface card (X6S,RJ45) V200R021C00 and
later versions
LST7G48TX6E0 48-port 100/1000BASE-T interface card (X6E,RJ45) V200R021C00 and
later versions
Power supply Supported
Version
W2PSD2200 2200W DC power module
PAC3KS54-CE 3000W AC power module (black) V200R019C00 and
later versions
PAC3KS54-NE 3000W AC power module (black) V200R020C10 and
later versions
License
L-1AP-S127E S127E Series,Wireless Access Controller AP Resource License-1AP
L-VxLAN-S127E S127E Series,VxLAN License, Per Device
RTU-800G-S127E S127E Series,800G Capacity Right to Use License,Per Device
CloudEngine S12700E Series Switches Datasheet-V2R21C00 27
License
N1-S127E-F-Lic N1-CloudCampus,Foundation,S127E Series,Per Device
N1-S127E-F-SnS1Y N1-CloudCampus,Foundation,S127E Series,SnS,Per Device,1Year
N1-S127E-A-Lic N1-CloudCampus,Advanced,S127E Series,Per Device
N1-S127E-A-SnS1Y N1-CloudCampus,Advanced,S127E Series,SnS,Per Device,1Year
N1-S127E-FToA-Lic N1-Upgrade-Foundation to Advanced,S127E,Per Device
N1-S127E-FToA- N1-Upgrade-Foundation to Advanced,S127E,SnS,Per Device,1Year
SnS1Y
N1-S127E-M-Lic N1-CloudCampus,Device Management,S127E Series,Per Device
N1-S127E-M-SnS1Y N1-CloudCampus,Device Management,S127E Series,,SnS,Per Device,1Year
N1-AC1.0-AM-15-Lic N1-CloudCampus,Access Management-AC1.0,15 Terminals
N1-AC1.0-AM-15- N1-CloudCampus,Access Management-AC1.0,15 Terminals,SnS,1Year
SnS1Y
CI-X7MSwitch-U CampusInsight-Upgrade-Foundation to Advanced, X7 Series Modular Switch, Per Device
CI-X7MSwitch-U- CampusInsight-Upgrade-Foundation to Advanced, X7 Series Modular Switch, SnS, Per Device, 1
SnS1Y Year
More Information
For more information about Huawei Campus Switches, visit http://e.huawei.com or contact us in the following ways:
⚫ Global service hotline: http://e.huawei.com/en/service-hotline
⚫ Logging in to the Huawei Enterprise technical support website: http://support.huawei.com/enterprise/
⚫ Sending an email to the customer service mailbox:
[email protected]Copyright © Huawei Technologies Co., Ltd. 2021. All rights reserved.
No part of this document may be reproduced or transmitted in any form or by any means without prior written
consent of Huawei Technologies Co., Ltd.
Trademarks and Permissions
and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective holders.
Notice
The purchased products, services and features are stipulated by the contract made between Huawei and the
customer. All or part of the products, services and features described in this document may not be within the
purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information, and
Huawei Technologies Co., Ltd.
recommendations in this document are provided "AS IS" without warranties, guarantees or representations of
any kind, either express or implied. Address:Huawei Industrial Base Bantian,
Longgang Shenzhen 518129 People's
The information in this document is subject to change without notice. Every effort has been made in the
Republic of China
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied. Website:e.huawei.com
CloudEngine S12700E Series Switches Datasheet-V2R21C00 28