Rate Cards
Rate Cards
SL NO ITEM DESCRIPTION
1 DISMANTLING & REPAIR WORKS
1.1 DISMANTLING RCC/CEMENT CONCRETE Dismantling RCC/cement concrete manually/ by
mechanical means including disposal of material within 2km lead as per direction of Engineer - in -
charge.
1.2 DISMANTLING OLD PLASTER Dismantling old plaster or skirting raking out joints and cleaning the
surface for plaster including disposal of rubbish to the dumping ground within 2km lead as per
direction of Engineer - in- charge.
1.3 REMOVING VEGETATION FROM CONCRETE STRUCTURE Removing vegetation by uprooting
stumps and disposal of rubbish including chipping and cleaning the area, applying two coat of epoxy
bonding agent, filling the area with high strength microconcrete, including cost of all materials,
scaffolding, conveyance , royalties and taxes, loading and unloading, labour,sundries, T&P
etc.completed as direction of Engineer In Charge. complete at all levels and locations and as directed.
Make: Bonding Agent - Nitobond EP, Micro Concrete - Renderoc LAXtra.
1.4 REPAIR OF UNSOUND/WEAK CONCRETE Chipping of unsound/weak concrete in surface of
concrete structure 40- 75mm thick with manual Chisel and/ or by standard power-driven percussion
type or of approved make including tapering of all edges, making square shoulders of cavities including
cleaning the exposed concrete surface and reinforcement with wire brushes/ oil free pressure air and
disposal of debris, applying two coat of anticorrosive primer in reinforcement, applying two coat of
epoxy bonding agent, filling the area with high strength micro concrete. including the cost of all
materials, scaffolding, conveyance, royalties and taxes, loading and unloading, labour, sundries, T&P
etc.completed as the direction of Engineer In Charge. complete at all levels and locations and as
directed. Make: NitoZinc Primer, NitoBond EP, Renderoc LAXtra or Equivalent.
2.2 PLAIN CEMENT CONCRETE 1:3:6 Supplying and Laying Plain Cement Concrete of Grade 1:3:6 with
stone aggregate of 40mm down size (including centering & shuttering if required) and with cement of
approved make as specified in all levelling courses under Foundation, Floors,rigid pavement,
Pits,trenches etc., at all heights / depths and floors including all materials, Manpowers, Machinery,
curing, scaffolding, complete as per Drawings/Specifications and direction of Engineer in charge.
Minimum cement content - 225kg/cum.
2.3 REINFORCED CEMENT CONCRETE - DESIGN MIX M30 Providing and laying in position Reinforced
Cement Concrete in Design mix of M-30 Grade; using Portland Pozzalana Cement (PPC) confirming
to IS 1489 part -II ; with river sand(Zone I/II) and 20mm and down graded hard stone broken stone
(minimum cement Content 400kg/cum), including supplying and mixing Super- Plasticizer of approved
brand/conforming to relevant IS Standard; including placing of concrete,providing pockets,openings,
recesses, chamfering wherever required etc., vibrating, tamping, curing and rendering if required. to
give a smooth and even surface etc. all complete (excluding the cost of reinforcement) for all
structures ( confirming to IS 456 ) as per the drawings, specifications and as directed by Engineering
incharge.
2.5 CENTERING AND SHUTTERING Centering and shuttering (Steel/Ply) for all structure including
strutting, propping etc. and removal of form after the required interval from the date of casting
including cost of all labours, materials, conveyance, loading and unloading, all taxes and royalties,
sundries and T&P etc all complete as per direction of the Engineer -in-charge.
2.6 EPOXY BONDING ADHESIVE Providing, mixing and applying bonding coat of approved adhesive on
chipped portion of RCC as per specifications including Cleaning of exposed concrete surface of
sticking loose and foreign material cleaning with oil free air blast as per direction of Engineer in charge.
Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make
2.7 DRILLING HOLES FOR REINFORCEMENT Drilling suitable holes in reinforced or plain cement
concrete with power driven drill machine to a minimum depth of 100mm upto 200mm in RCC beams,
lintels, columns and slabs to introduce steel bars for Wall/sunshades/balconies including fixing the
steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of
reinforcement, all complete as per direction of Engineer-In- Charge.A) Upto and including 16mm dia.
2.8 CORE CUTTER Drilling with core cutting machine in RCC slabs, walls etc.wherever required in
buildings, manholes,ducts etc. for laying/fixing pipes, and making good the same to give an even
finish. The rate shall include the cost of drilling core, providing water proofing compound for sealing the
joints around the pipes, nominal reinforcement wherever required, scaffolding and labour charges for
working at all levels, leads and heights. (Thickness of RCC members may be varry from 50mm to
1000mm) and as directed by Engineer-In-Charge. (Core Dia varrying from 20mm to 100mm)
2.9 CORE CUTTER Drilling with core cutting machine in RCC slabs, walls etc.wherever required in
buildings, manholes,ducts etc. for laying/fixing pipes, and making good the same to give an even
finish. The rate shall include the cost of drilling core, providing water proofing compound for sealing the
joints around the pipes, nominal reinforcement wherever required, scaffolding and labour charges for
working at all levels, leads and heights. (Thickness of RCC members may be varry from 50mm to
1000mm) and as directed by Engineer-In-Charge. (Core Dia varrying from 100mm to 150mm)
2.1O BRICK WORK BELOW PLINTH Construction of Brick work in below plinth using fly ash bricks of size
230x110x75 mm thick with minimum compressive strength of 75 kg/sqcm in cement mortar (1:4)
including curing and watering including cost of bricks and all materials, scaffolding, conveyance ,
royalties and taxes, loading and unloading, labour,sundries, T&P etc.completed as direction of
Engineer In Charge.
2.11 CEMENT PLASTERING(1:5) 12mm THICK Providing 12 mm thick cement plaster 1:5 ( 1 cement: 5
fine sand) finished including all materials and manpowers, cleaning, hacking of base surfaces,
providing scaffolding,watering and curing, finishing etc. all complete for all heights as per specifications
and directions of Engineer in Charge. No extra payment shall be made for additional thickness if
required to achieve perfect line and level.
2.12 CPVC PIPE 25mm DIA Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) 25mm dia pipes
conforming to IS 15778 Class 1 SDR11 upto 50mm & Class 3 SDR17 above 50mm,having thermal
stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing
the pipe with clamps at 1.00 m spacing. including cutting walls & floor & making good the damages,
This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints
complete as per direction of Engineer in Charge.
2.14 JET PUMP fixing & Commissioning of 2HP deep well Pump with constant pressure water supply of
average discharge pressure comprising of horizontal or vertical mounted, single outlet.. Pump having a
suction lift head 90m head & delivery size 50mm with cast iron casing, stainless steel or Bronze
impeller and shaft and electric motor operating on Single phase, AL supply of 180-240V. The pumps to
be installed in the pump room or under small sheds. Each Pump shall be controlled with Auto switch
connected to the controlled panel. Necessary cabling for Power and control having a total length of
about 50 Rmt shall be laid for auto control. The installation shall include suction pipe from the pump to
the water tank. This suction pipe, shall be fitted to the foot valve. They will be one size higher than the
pipe suction diameter. The quoted price shall be inclusive of the Foot Valve, Suction pipe, Installation
of pump, Suction valve and strainer and discharge NRV and valve and Pressure Vessels. There shall
be separates Electrical Feeder provided for each pump. The starter electrical panel with all protection
and Amp Meter / Volt Meter / Auto Manual selector shall be in the scope of the supplier. Complete as
per direction of Engineer In Charge. Make: Kirloskar or Equivalent
3.2 WATERTIGHT SEALING GROUT INJECTION Providing low viscous, elastic PU grouting by using
"Sika Injection 201CE" grout material or its equivalent approved quality material like "Sika", "Fosroc" or
"BASF" make, pressure grouting shall be done with heavy pressure pump by injecting the grout
materials in sealed nozzles or metal packers for strengthening of concrete or arresting the leakage,
seepage water by grout injection gun at grouting pressure range minimum about 4 Kg / cm2 or as per
manufacture specification including all pumping system & machinery by providing low viscous water
insensitive grout of approved manufacturer’s specifications and injecting till the refusal by allowing
properly setting & sealing the nozzles without wasting the injecting materials and making the system
complete safe / water tight as required etc. complete as directed. Payment shall be made per Kg. of
material net utilized during the grouting operation. Wastage of material will not be considered for the
payment. including cost of all materials, cleaning of base surfaces, providing scaffolding, watering and
curing, finishing etc. all complete for all heights as per specifications and directions of Engineer in
Charge
3.4 SEALANT FOR EXPANSION JOINTS Providing and laying polysulphide sealant for expansion joints of
approved make Including chipping upto required depth, cleaining, surface preparation, applying primer
with approved make, backer rod, sealant with approved make, curing make as per drawing,
manufacturer specification to give water tightness, etc. including cost of all materials, cleaning of base
surfaces, providing scaffolding, watering and curing, finishing etc. all complete for all heights as per
specifications and directions of Engineer. Make: Sika PolySulphide Gun Grade.
4.4 WATER PROOFING TREATMENT ON SUNKEN AREA Providing and laying integral cement based
water proofing treatment in sunken portion of WCs, bathroom etc., including preparation of surface as
required for treatment of roofs, terraces etc consisting of following operations:_x000D_
(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with 2% water proofing
compound conforming to IS. 2645 over the RCC slab including adjoining walls upto 300 mm height
including cleaning the surface before treatment. (b) Second layer of 1.5 mm thickness consisting of
slurry of cement @ 1.289 kg/sqm mixed with 2% water proofing cement compound @ 0.670 kg/sqm
and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing
for 48 hours. Including treatment and sealing of all joints, corners, junctions of pipes and masonry.
The rate include cost of all materials, labour conveyance , royalties and taxes, loading and unloading,
labour,sundries, T&P etc.completed as direction of Engineer In Charge.
4.5 WATER PROOFING TREATMENT BY CRYSTALLINE SLURRY Providing and applying integral
crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining
walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant,
tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral
crystalline slurry : 2 parts water) for vertical/Horizontal surfaces and applying the same from negative
(internal) side with the help of synthetic fiber brush. The material shall meet the requirements as
specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared
with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side.
The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall
be carried out all complete as per specification and the direction of the engineer-in-charge. The
product performance shall carry guaranteed for 10 years against any leakage.
5.3 SURFACE PREPARATION FOR PAINTING (STEEL WORKS) Surface preparation of steel structure to achieve
ST3 by hand tools (wire brushing, chipping, scraping and sanding, etc.) and/or power tools (power sanders or wire
brushes, power chipping hammers, abrasive grinding wheels, needle guns etc.) with proper protection and
cleaning by vacuum cleaner and dry compressed air and also by use of solvent to the extent necessary as and
when required to clean the surface off any rust, moisture, loose/ perished paints, remove oil, grease, dust, scales
etc. The rate includes cost of all materials, labours, machinery, equipments, scaffolding, staging and all other
incidental charges, all complete as per specification and direction of Engineer in Charge. At All heights & Levels
5.3 HIGH BUILD EPOXY PAINTING Supplying and applying of finished paint consist of two coats of Acrylic
Polyeurethene paint (Bergerthane PU or equivalent) of approved shade to give dry film thickness of 35 micron per
coat of synthetic enamel ( Berger, Asian paints, Shalimar etc approved by EIC ) followed by a one coat of two
components high build epoxy Micaceous Iron Oxide (MIO) pigmented intermediate coat conforming to IS 16943
(Berger EPILUX 155 HB MIO or equivalent) at dry film thickness of 100 micron. one coat of zinc phosphate primer
with 50 micron DFT ( BergerEpilux 610 Primer Red Oxide/Grey or equivalent over a coat of zinc phosphate primer
( BergerEpilux 610 Primer Red Oxide/Grey or equivalent) on steel structures including cost of all materials, labour,
scaffolding, staging , tools etc. all complete as per specification and direction of Engineer in charge.[ Total dry film
thickness of all the coats including primer coat should not be less than 220 micron] At All heights & Levels
SQM
1000
EA
(Each/Number)
200
SQM
1000
CUM
200
CUM
200
CUM
150
SQM
1000
SQM
500
NO
1000
RM
800
RM
800
CUM
100
SQM
1000
RM
2000
1500
NO
EA
(Each/Number)
200
EA
(Each/Number)
200
RM
500
850
SQM
850
SQM
850
SQM
500
SQM
500
SQM
800
850
KG
100
SQM
2000
SQM
1500
UOM
No
Sand filling (Free from any vegetation, organic etc ) with compaction as mentioned
A7 in drawing in layer as per engineer in charge instruction, in case of pure sand CUM
flooding with water is permissible as per the diretion of Engineer in charge.
SCV721415000005
Stone dust filling (Free from any vegetation, organic etc ) with compaction as
A8 mentioned in drawing in layer as per engineer in charge instruction, in case of pure CUM
sand flooding with water is permissible as per the diretion of Engineer in charge.
Providing and laying Pitching to slopes, grade separation and sides of storm water
drains/water pond including breaking of rubble, voids to be filled with sand,
A9 formation of neat slopes to required profile, watering, tamping, raking out joints and
grouting them in cement mortar 1:3 as per the diretion of
Engineer in charge.
i 300mm thick pitching using 300 mm down black granite stones SQM
PART B - CONCRETING
SCV721527000005 B1 M15 CUM
SCV721527000008 B2 M20 CUM
B3 M20 grade in substructure CUM
B4 M20 grade in superstructure CUM
SCV721519050054 B5 M25 grade for substructure. CUM
SCV721519050054 B6 M25 grade for superstructure. CUM
SCV721527000006 B7 M30 grade for substructure CUM
SCV721527000006 B8 M30 grade for superstructure. CUM
Pressure Grouting treatment including placing & fixing 12mm/15mm dia. threaded
B16 nozzles of suitable length, in grid pattern of 1500 mm c/c, making the surface water SQM
tight with grouting through nozzles / sealing with polymeric sealing compound
SCV721540120005 Breaking of R.C.C in floor and disposing debris complete in all respect as diected
B19 CUM
by the EIC.
PART C - MASONRY AND PLASTERING
Providing Constructing first class Fly ash brick masonry of thickness 230 mm and
above in bricks conforming to clas 35A of IS1077 at all heights and depths for
C retaining walls,wall footings, parapets, partitions, steps, drains, manholes, trenches,
etc. including curing and all finishing activities complete
in all respect.
SCV721520000003 Cement punning for walls, ceilings, etc. after necessary surface
C9 SQM
preparation and including scaffolding, etc. complete as per direction of EIC
PART E - FLOORING & TILING,CEILING
Providing and laying Anti Skid Ceramic tile flooring of kajaria - opera beige (or
johnson project line series, nitco diamond series make) of size 300 X 300 mm
or of approved brand and shade, with paper thin joint and to required slope, set on
20mm thick cement mortar 1:4, including providing cement slurry and pointing of
E1 joints with tilemate or equivalent to match the colour of tiles, curing, oxalic acid SQM
washing etc., covering with POP/ Jute for the same complete. The rate shall include
providing patterns, borders, inlays etc complete with all leads & lifts at all levels as
per specifications given in the drawings, and as per the instructions of Engineer in
Charge.
SCV721525040016
Providing and fixing ceramic wall tiles of approved quality & shade (Make:
Kajaria/ Bell/ Johnson or equivalent) on wall at all positions , set jointed in neat
E2 SQM
cement slurry, laid on 25 mm thick plaster with CM 1:6 complete as per direction of
SCV721525040015 EIC.
Providing and laying wall tiles (ceramic based decorative type) 315 x 420 joint free
E4 SQM
on a 25 mm thk bedding of cement mortar (1:3)
Providing and laying Vitrified tile flooring of Kajaria kerrogress - 6029(or johnson
project line series, nitco diamond series make) of size 600 X600 mm, with paper
thin joint and to required slope, set on 20mm thick
cement mortar 1:4, including providing cement slurry and pointing of joints with
E5 SQM
Acid Resistant or equivalent to match the colour of tiles, curing,
oxalic acid washing etc., ,covering with POP/ Jute for the same. The rate shall
include providing patterns, borders, inlays etc complete at with allleads & lifts all
levels as per specifications given in the drawings, and as per the instructions of EIC.
Flooring Providing and laying to slopes and levels thichkness 30mm cement
concrete M20 by using graded coarse aggregate size 12.5 mm and down size
E7 SQM
including surface preparation by one coating of plain cement mortar, compaction,
curing, etc. complete, as specified & directed by the EIC.
Providing and fixing false ceiling with 12mm thick gypsum anhydrous board and
SCV721523020002 E8 aluminium section including support hanger,screwing,accesoories,tools and tackles SQM
etc complete as per direction of EIC
Providing & fixing Solid wooden flooring of Pergo - 028031 antique oak of size
1.20 X 1.80 m (or other approved make) finished as per theArchitect's approval.
The Flooring shall be laid to lines & levels as shownin the drawing. The sub floor
shall be free of moisture & other laitence.The underlay shall be resilent of 15mm
foam pad & shall be laid on levelled surface. The finished flooring material shall be
E9 12.4mm total thicknesswith 3.6mm wear layer on top.The edges of the sub foam SQM
shall be lapped toa minimum of 1" & sides of the wooden floor shall have a tongue
& groovejoint. The foam shall be properly struck on the concrete surface below
witha foam adhesive. the rate shall also include cost of tanstition profilling ofjoints
of different flooring materials & reducers wherever necessary with all leads & lifts
at all levels etc., complete & and as per the instructions of EIC.
Providing & fixing 100mm high Solid wooden skirting of Pergo - 028031 antique
oak of size 1.20 X 1.80 m (or other approved make) of approved thickness using
E10 adhesives, quality, make and shade as per the design shown in the drawing. The rate RMT
shall include all leads & lifts at all levels & finishing as per the standard etc.,
complete and as directed by EIC
Providing & fixing Laminated wooden flooring for Master bedrooms of Grand
teak Indiana AC - 4grade of size 0.20 X 1.20 m (or other approved make) finished
as per the Architect's approval. The Flooring shall be laid to lines & levels as shown
in the drawing. The sub floor shall be free of moisture & other laitence.The
underlay shall be resilent of 15mm foam pad & shall be laid on levelled surface.
The finished flooring material shall be 12.4mm total thickness with 3.6mm wear
E11 Sqm
layer on top.The edges of the sub foam shall be lapped to a minimum of 1" & sides
of the wooden floor shall have a tongue & groove joint.
The foam shall be properly struck on theconcrete surface below with a foam
adhesive. the rate shall also includecost of profilling of joints of different flooring
materials & reducerswherever necessary with all leads & lifts at all levels etc.,
complete & andas per the instructions of Engineer in Charge
Providing & fixing 100mm high Laminated wooden skirting for Masterbedrooms
of Grand teak Indiana AC - 4grade (or other approved make) ofapproved thickness
E12 using adhesives, quality, make and shade as per the design shown in the drawing. RMT
The rate shall include all leads & lifts at alllevels & finishing as per the standard
etc., complete and as directed by EIC.
Providing and laying single piece machine cut 20mm thk pre polished Granite
stone slab flooring to be layed over a bed of 20mm thick CM 1:4 inclusive of
pointing of joints with pigment to match the colour of stone,making hole for grill
E13 fixing, curing, covering with P.O.P/ jute & cleaning when required complete. The SQM
rate shall include providing patterns, borders,inlays etc complete with all leads &
lifts at all levels as per specifications given in the drawings, and as per the
instructions of EIC.
Providing & laying Pre polished Marble skirting 100 mm high fixed over a bed of
10mm thick CM 1:4 & adhesives, including chasing wall where necessary, making
good the chased surface, curing, covering with POP cleaning, pointing of joints
with white/coloured cement,joints should be paper thin finish, curing and making
E16 groove at the junction of plastering RMT
and skirting , including half round edge polishing. The rate shall include providing
patterns, borders, with total 7 coats of polishing after laying etc.,complete with all
leads & lifts at all levels as per specifications given in the drawings, and as per the
instructions of EIC.
Providing and fixing Kota stones of thickness (22-25mm) approved size and brand
laid over cement sand mortar of thickness 20mm in 1:3 propertion with proper
E19 SQM
slope/gradient including all finishing work like polishing, grouting etc. complete in
all respect as per the instruction of the EIC.
Providing and fixing Kota stones of thickness (18-20mm) approved size and brand
laid over cement sand mortar of thickness 20mm in 1:3 propertion with proper
E20 SQM
slope/gradient including all finishing work like polishing, grouting etc. complete in
all respect as per the instruction of the EIC.
Providing and fixing Kadpa stones of thickness (25-45mm) approved size and
brand laid over 20mm thick cement sand mortar in 1:3 propertion inapproved
E21 pattern with proper slope/gradient and including all finishing work like polishing, SQM
grouting etc. complete in all respect as per the instruction of the
EIC.
Supply & fixing of glass mosaic tiles for swimming pool matching with existing
E22 flooring in colour, pattern &thickness including the cost of tools, tackles,fixing SQM
resin,masionary work etc. as per the instructions of EIC
Providing and laying of Pre -polished 20mm thick White Marble flooring for
treads & risers, to be fixed in over a bed of 20mm thk CM 1:4, inclusive of
pointing of joints with pigment to match the colour of tile, curing, ploishing &
E27 cleaning when required etc complete. The rate shall include providing patterns, SQM
making grooves & making front edge half round etc., complete with all leads & lifts
at all levels as per specifications given in the drawings, and as per the instructions
of EIC.Staircase
Providing and laying of Pre -polished 20mm thick granite flooring for treads &
risersof entrance steps, to be fixed over a bed of 20mm thick CM 1:4 inclusive of
pointing of joints with pigment to match the colour of tile
E28 ,curing, & cleaning when required etc complete. The rate shall include providing SQM
patterns, borders, inlays etc complete with all leads & lifts at all levels as per
specifications given in the drawings, and as per the instructions of Engineer in
Charge
Providing & laying 20mm thk. Pre-polished marble Urinal partitions of size (1.5
x 0.6) as per the detailed drawing, polished on both side with bull nosing at exposed
edges, including cutting groove in wall,finishing/grouting with cement
E29 mortor,making provision for fixing bolts and nuts, sealing the joints with sealant SQM
(Dow corning), curing, cleaning when ever instructed, pointing of joints with
white/coloured cement, etc.,complete with all leads & lifts at all levels &as per the
instructions of EIC.
Providing and laying Clay tiles for Terrace floor (slopped roofs) of approved
size, make, quality and uniform shade with paper thin joint set in 20mm thick
cement mortar 1:4 with cement slurry and pointing of joints with tile grout of
E31 SQM
approved make to match the colour of tile curing, etc complete at all levels as per
specifications and drawings, including all leads and lifts as
per the instructions of EIC.
Providing and fixing of BWP Plywoodof 18/19mm thickness including all
E32 tools,tackles,accessories and materials required for fixing and complete as per the SQM
direction of EIC.
Polishing of statues of man height and width giving a clear finish and shine
E34 to the existing strcuture.Surface should be rubbed to remove flacks and cleaned Nos
properly prior application of primer and paint.
PART F - WATER PROOFING
Providing and laying to slopes and levels cement concrete screeding M20 by using
F1 20 mm nominal size metal aggregates including surface preparation, compaction, SQM
curing, etc. complete, upto 75mm as specified & directed by EIC
Supply & application of Siliconate injection grout mixing with water by 1:5 or
F2 LTR
1:10 for rising dampness in brick masonary(DAMPFREE)
Supply & application of Dampproof coating with OPC cement Putty for
F3 internal walls,ceilings & RCC water Tanks(DAMPGUARD)(35-40SqFt per KG for KG
two coat)
Supply & Application of acrylic Bonding Agent(PIDICRETE MPB) on old
F4 KG
concrete/plastered surfaces as a neat coat(75-80Sqft per KG)
Providing and laying protective screed of average 50 mm thick admixed with
integral liquid waterproofing compound of STP or equivalent prime manufacturer
(Conforming IS 2645: 2003) as per Manufacture specification, on the coated floor
surface in panels (4' X 4') filling the joints with bitumen filler & providing and
applying mortar admixed with a Shali SBR polymer modified SBR based emulsifier
F5 or with product of equivalent prime manufacturer on coated surface of cant strip
(rounding ),parapet wall including all tools, tackles, materials in complete as per the
instructions of EIC in adherence to standard procedures of safety.(All material
storage, transportation & security will be in party’s scope.)
i M15 SQM
F6 Pressure Grouting in nozzles Nos
Application of elastometric Cementitious waterproof coating such that
F7 porosity of concrete structure will be filled up and give a water resistant surface
i Apply and supply of FORSOC MAKE Nitocote CM210/or Equivalent SQM
ii Apply and supply of FORSOC MAKE Nitoseal PU40 or Equivalent SQM
iii Epoxy based SQM
Erection of Scaffolding-Staging(1set).Scaffolding with ledger and cuplock system
F8 such that workable platform can be made over it which includes supply and doing CUM
stagging at appropriate location including MS jally etc
PART G - DOORS, WINDOWS AND VENTILATORS,CANOPYS
Providing and fixing in position 40mm thick superior class Indian teak wood
panelled door in 65mm x 140mm teak wood frame including fixing screws,
G1 holdfasts, copper oxidised brass fixtures, stoppers, glazing, beading, architrave, a SQM
coat of coal tar etc. complete in all respect as per the direction of
EIC.
G1.1 Non-decorative type with commercial plywood on both faces SQM
Providing and fixing in position M.S. Steel windows IS:1038 with standard rolled
sections including 4 mm thick plain sheet glass with necessary holdfasts, oxidised
G2 brass fixtures/fastners, putty, glazing clips, peg stay,
handle, tower bolts, screws etc.
G2.1 With 60% openable windows/ventilators SQM
G2.2 With 100% openable windows / ventilators SQM
Providing & Fixing universal type hydraulic door closer of approved quality
G5 Nos.
complete
Providing and fixing in position Patch fitting doors, 12mm thick Toughened Glass
with etching, door shutter
mounted on SS corner patch fitting brushed steel finish, floor spring to strutural
glazing frame, corner
G6 SQM
locks, SS handles including removing of existing glazing and finishing the same all
as per detailed
drawings etc., complete and as directed by Engineer-in-charge. (Includes all leads
and lifts at all levels)
Providing & fixing of approved make & colour PVC doors with necessary
G7 SQM
accessories,locks,door stoppers etc complete as per the direction of EIC.
Providing and fixing of floor spring of approved make including removal of
G8 existing floor spring with all necessary tools,tackles and accessories,floor cutting NO
etc required for fixing to complete the work as per the direction of EIC
Proving and fixing silicon sealant in glass door/Partition/ any joints/ACP panels etc
G9 RM
to fill the gap and complete the work as per the direction of EIC.
Provide and Fixing of 4 mm toughened glass in Aluminium pivoted/Sliding
G10 Sqm
windows /Doors with necessary fittings by usings tools and tackels.
Providing and Fixing 100 mm wide Indian fabric for vertical blinds of approved
G11 make, colour and texture including all fittings of approved quality complete as Sqm.
directed by the Architects - Basic Rate - Rs.120/- Sft
G12 Providing and fixing Tower bolts(8-10") Nos
G13 Providing and fixing Cylindrical door locks Nos
G14 Providing and fixing door handles Nos
GLASS DOOR LOCK(15 mm)
G15 Nos
Brands may vary as per the site requirement
G16 Rubber Gasket mtr
Supply & Fixing of Aluminium Partition Wall made of natural matt finish
anodized HINDAL aluminium section of size 2.5"*1.5" inch (or equivalent) with
G17 SQM
1.2 M height smoke glass at 0.9 M height from finished floor level including all
accessories,tools,labour cost etc as per the instructions of EIC.
Supply & Fixing of Aluminium Partition Wall made of natural matt finish anodized
HINDAL aluminium section of size 2.5"*1.5" inch (or equivalent) with
G18 1.2 M height smoke glass at 0.9 M height from finished floor level & aluminium SQM
sheet as partition material (design as per EIC) including all accessories,tools,labour
cost etc as per the instructions of EIC.
Replacement of laminates over partitions,furniture,doors etc. including removal of
G19 existing damaged laminates including all tools,tackles,
material,pasting gum etc. as per the instructions of EIC.
G19.1 Ply Laminates/Vinier etc. SQM
Supply, fabrication & erection of structural steel including site Storage, Hiring
Hydra, trailor/truck/tractor, site handling loading ,unloading ,shifting, inspection &
testing where required, minor rectification, ,standard fitments etc. with rolled
SCV721525090004 section/entirely from angles, channels, chain linked fence material, MS
L19 MT
plates,CANOPY etc. at all levels including unpacking, minor cutting, welding,
grinding, bolting, threading, assembly including fixing of fasteners, complete
erection, assembly & alignments, plumbing, erection of brackets, etc. as per
drawing as per site requirement & as per the directions of EIC.
M Sanitary
Repairing of flushing system in toilets with necessary fittings .All the necessary
M1 Nos
fittings are supplied by contractor to complete the work as per the direction of EIC.
Providing and fixing P.V.C Over head (Sintex make) tank with all
pipings,jointers,elbow etc. and valve arrangement with all labour & materials Nos
M2
,including cost, T&P , scaffolding etc., complete as directed by the Engineer- in-
charge.
N SEWERAGE DISPOSAL
Supply of all materials, joining materials , labour and T&P and laying UPVC SWR
PIPES of Standard make with ISI Mark duly approved by the Engineer- in- charge
N1
including jointing, earthwork in excvation of trenches in all kind of
soil to the required depth
i 150mm dia ( ISI Marked) Rmt.