0% found this document useful (0 votes)
144 views

Schema ELEC

This document provides confidential technical specifications for a recycling plant project, including circuit diagrams for a FRX2000 shredder machine. It lists information about the power supply, control voltages, wire colors, and minimum conductor sizes for the electrical system. The infeed power is specified at 554 kVA and the electrical system is rated to withstand short circuits.

Uploaded by

Meyer
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
144 views

Schema ELEC

This document provides confidential technical specifications for a recycling plant project, including circuit diagrams for a FRX2000 shredder machine. It lists information about the power supply, control voltages, wire colors, and minimum conductor sizes for the electrical system. The infeed power is specified at 554 kVA and the electrical system is rated to withstand short circuits.

Uploaded by

Meyer
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 133

CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|MCC01|PAB.

16:42:09
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Final date of print: 30.03.2020

Customer: RECYCLING-STANDARD
Order:
Project no.: ZC133238545
Project: RECYCLING-PRODUCTS

Part: PENA - FRX2000


Location: FRX2000
Circuit diagrams

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Shredder FRX-2000 Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner MCC Project no.: ZC133238545 Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 MCC Cabinet - Cover sheet Customer: RECYCLING-STANDARD Page: 1 / 133 1 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|MCC01|PAB.2 Final date of print: 30.03.2020

0 1 2 3 4 5 6

Min. conductor
Voltage Color of wires
size:
Power supply / Distribution 400 VAC 50 Hz black 2,5 mm²
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

A A
Neutral conductor light blue
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

Protective earth yellow, green

Control voltage 230 VAC red 1,5 mm²

Control voltage 24 VDC dark blue 0,75 mm²

Power supply / Before main circuit breaker 230 VAC 50 Hz yellow

B B

Analog signal 4-20mA white, shielded cable 0,75 mm²

External voltage VAC orange 1,5 mm²

Electrical system: Short-circuit withstand capability:


Infeed power: 554 kVA
Infeed voltage: 400 V Prospective short-circuit current at supply terminals Icp: 55 kA
C Design current: 800 A Prospective short-circuit current in the neutral: % C
Short circuit current (Icw): -A
Protection of persons against electric shock
Design temperature: 40 °C in accordance with IEC 60364-4-41:
Earthing system: TN-S
Transient overvoltage category: III Type of protection against electric shock: Basic protection (protection against direct contact)
Temporary overvoltages: 1000 V
Installation environment: Installation method:
Rated Frequency: 50Hz
expressly agreed to by ANDRITZ AG or one of its affiliates.

400 VAC/ 230 VAV/ 24VDC Location type: Outdoor Type:


Used Voltages:
System of protection: IP55 stationary/movable: stationary
Terminal designation: Ambient air temperature - Lower limit: -20 °C External conductor type(s): cable
-X0 : Incoming feeder 400V AC Ambient air temperature - Upper limit: 40 °C Direction(s) of external conductors: bottom
-X1 : 400V AC MCC Max. relative humidity: 80 External conductor material: copper
D -X2 : 230V AC D
Pollution degree (of the installation environment): 3
-X3 : 110V AC
max. Altitude of location: 1000 m
-X4 : 24V DC
-X5 : External potential EMC environment: A
-X6 : Digital input
-X7 : Digital output
-X8 : Analog input
-X9 : Analog output
Manufacturing according IEC 61439
-X10: Emergency stop
-X11: Others
Device identification with self adhesive labels on the device itself and on the mounting plate
-X16: Digital input 230V AC
-X17: Digital output 230V AC
E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Shredder FRX-2000 Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner MCC Project no.: ZC133238545 Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 MCC Cabinet - Datasheet EMCR (IEC 61439) Customer: RECYCLING-STANDARD Page: 2 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
0 1 2 3 4 5 6
16:42:12
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will
neither copy, reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|MCC01|PAB.3 Date of print: 30.03.2020
Project name: RECYCLING-PRODUCTS Table of contents
Project number: ZC133238545 Doc. no.: 508627696_EN_0 for
Project description: Recycling Products Status: Final .PFSS_.300_FRAN.332.4.A / Combined
Customer: RECYCLING-STANDARD Customer Shredder FRX-2000
Customer project no.: doc. no.: MCC

Created Checked

Pages
Label/ Revision Document number Document number
Sheet number
Unit / Location / Funct. Description 1 Description 2 Description 3 Status
Description ANDRITZ customer

Rev.
date by date by

General
1 / +B4I.MCC01 / Cover sheet Shredder FRX-2000 MCC 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
2 / +B4I.MCC01 / Datasheet EMCR (IEC 61439) Shredder FRX-2000 MCC 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
3 / +B4I.MCC01 / Table of contents Shredder FRX-2000 MCC 4 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
Layout Drawings
7 / +B4I / Layout drawing and earthing - schematic Shredder Shredder FRX-2000 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
8 / +B4I.CB01 / Design plan A3 MCC Local Control Panel 1 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
9 / +B4I.CB02 / Design plan A3 MCC Local Control Panel 2 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
10 / +B4I.JB01 / Design plan A3 Machine Junction Box 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
11 / +B4I.JB05 / Design plan A3 Machine JB Slip Montoring 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
12 / +B4I.JB10 / Design plan A3 Machine JB Condition Monitoring 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
13 / +B4I.JB02 / Design plan A3 Hydraulic Panel Junction Box 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
14 / +B4I.MCC01 / Design plan A3 MCC MCC Cabinet 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
15 / +B4I.MCC01 / Design plan A3 MCC MCC Cabinet 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
16 / +B4I.MCC01 / Design plan A3 MCC MCC Cabinet 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
Circuit Diagrams
17 / +B4I.MCC02 / Circuit diagram MCC Power Distribution 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
18 / +B4I.MCC01 / Supply MCC MCC Cabinet 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
19 / +B4I.MCC01 / Distribution MCC MCC Cabinet 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
20 / +B4I.MCC01 / Cabinet light/heater MCC MCC Cabinet 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
21 / +B4I.MCC03 / Cabinet cooling MCC VFD Cabinet 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
22 B.00A01.X2 / / XS ES extension MCC Cabinet MCC Signals 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
23 B.00A02.H1 / +B4I.CB01 / HSZ Emergency Stop Local Control E-Stop 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
24 / +B4I.CB016 / HMI LCP MCC Local Control Panel 1 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
25 / +B4I.MCC01 / HMI MCC MCC MCC Cabinet 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
26 / +B4I.MCC01 / ET200SP Overview MCC MCC Cabinet 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
27 / +B4I.MCC01 / ET200SP Overview MCC MCC Cabinet 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
28 / +B4I.MCC01 / S7-1200 Overview MCC MCC Cabinet 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
29 / +B4I.MCC01 / PC and Network Overview MCC MCC Cabinet 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
30 B.00A02.H7 / / SF Maintenance Switch Local Control Maintenance Switch 1 As Built 508627696_EN_0
31 B.00A01.X1 / +B4I.MCC01 / XS Circuit diagram MCC Cabinet Interface Main Controller 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
32 B.00A02.X12 / +B4I.LCP01 / XI Signal Horn Local Control Local Status Indication 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
33 B.00A01.X1 / +B4I.MCC01 / XS Circuit diagram MCC Cabinet Interface Main Controller 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
34 B.00A02.H2 / +B4I.CB01 / HS Circuit diagram Local Control Control Voltage On/Off 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
35 B.00A02.H3 / +B4I.CB01 / HS Circuit diagram Local Control Indication / Reset / Fault 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
36 B.00A02.H4 / +B4I.CB01 / HS Circuit diagram Local Control Operation Mode 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0

Rev. Rev.Date Created Checked Description of Revision Creation date: 05.03.2020


Created: Prettner
Checked: Pereira-Perez / 05.03.2020
Page: / Of: 1 /133 3 /133
16:42:12
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will
neither copy, reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|MCC01|PAB.3 Date of print: 30.03.2020
Project name: RECYCLING-PRODUCTS Table of contents
Project number: ZC133238545 Doc. no.: 508627696_EN_0 for
Project description: Recycling Products Status: Final .PFSS_.300_FRAN.332.4.A / Combined
Customer: RECYCLING-STANDARD Customer Shredder FRX-2000
Customer project no.: doc. no.: MCC

Created Checked

Pages
Label/ Revision Document number Document number
Sheet number
Unit / Location / Funct. Description 1 Description 2 Description 3 Status
Description ANDRITZ customer

Rev.
date by date by

37 B.00A02.H6 / +B4I.CB01 / HS Circuit diagram Local Control Automatic Start/Stop 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
38 B.00A02.X11 / +B4I.MCC01 / XI Circuit diagram Local Control Signal Horn 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
39 B.10B1.L1 / +B4I.MCC01 / LS Circuit diagram Feeding Chute Level High 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
40 B.20A1-M1 / +B.Local.20 / M Cabinet diagram Power Shredder MCC 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
41 B.20A1-M2 / +B.Local.20 / M Cabinet diagram Power Shredder MCC 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
42 B.20A1.G1 / +B4I.JB05 / GS Circuit diagram Shredder Position Monitoring RH 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
43 B.20A1.G2 / +B4I.JB05 / GS Circuit diagram Shredder Position Monitoring LH 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
44 B.20A1.H2 / +B4I.CB01 / HS Circuit diagram Shredder Local Operation 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
45 B.20A1.H3 / +B4I.CB02 / HS Circuit diagram Shredder Local Operation 2 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
46 B.20A1.S1 / +B4I.MCC01 / SI Circuit diagram Shredder Speed Indication 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
47 B.20A1.T1 / / TI Circuit diagram Shredder Gearbox temperature control 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
RH
48 B.20A1.T2 / / TI Circuit diagram Shredder Gearbox temperature control 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
LH
49 B.20A1.V1 / / XS Circuit diagram Shredder Condition Monitoring 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
50 B.20A1.V2 / / XS Circuit diagram Shredder Vibration DE 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
51 B.20A1.V3 / / XS Circuit diagram Shredder Vibration NDE 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
52 B.20A2.G1 / +B4I.MCC01 / GS Circuit diagram Pusher Pusher in Rear Position 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
53 B.20A2.G2 / +B4I.MCC01 / GS Circuit diagram Pusher Pusher in Front Position 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
54 B.20A2.H1 / +B4I.CB01 / HS Circuit diagram Pusher Local Operation 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
55 B.20A2.H2 / +B4I.CB02 / HS Circuit diagram Pusher Local Operation 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
56 B.20A3.G1 / +B4I.MCC01 / GSZ Circuit diagram Service Hatch Service Hatch Closed 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
57 B.20A3.G2 / +B4I.MCC01 / GS Circuit diagram Service Hatch Service Hatch Unlocked 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
58 B.20A3.G3 / +B4I.MCC01 / GS Circuit diagram Service Hatch Service Hatch Locked 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
59 B.20A3.H1 / +B4I.CB01 / HS Circuit diagram Service Hatch Local Operation 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
60 B.20A4.G1 / +B4I.MCC01 / GSZ Circuit diagram Reject Hatch Reject Hatch Closed 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
61 B.20A4.G2 / +B4I.MCC01 / GS Circuit diagram Reject Hatch Reject Hatch Unlocked 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
62 B.20A4.G3 / +B4I.MCC01 / GS Circuit diagram Reject Hatch Reject Hatch Locked 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
63 B.20A4.H1 / +B4I.CB02 / HS Circuit diagram Reject Hatch Local Operation 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
64 B.20A5.G1 / +B4I.MCC01 / GSZ Circuit diagram Screen Basket Screen Basket Closed 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
65 B.20A5.H1 / +B4I.CB02 / HS Circuit diagram Screen Basket Local Operation 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
66 B.20A6.X1 / +B4I.MCC01 / XS Circuit diagram Greasing Unit Lubrication Control 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
67 B.25A1.L1 / / LS Circuit diagram Hydraulic Panel Hydraulic Level Low 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
68 B.25A1.P1 / / PDS Circuit diagram Hydraulic Panel Diff Pressure Oil Filter High 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
69 B.25A1.V1 / / HS Circuit diagram Hydraulic Panel Pusher 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
70 B.25A1.V2 / / HS Circuit diagram Hydraulic Panel Service Hatch 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
71 B.25A1.V3 / / HS Circuit diagram Hydraulic Panel Screen Basket 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0

Rev. Rev.Date Created Checked Description of Revision Creation date: 05.03.2020


Created: Prettner
Checked: Pereira-Perez / 05.03.2020
Page: / Of: 2 /133 4 /133
16:42:12
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will
neither copy, reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|MCC01|PAB.3 Date of print: 30.03.2020
Project name: RECYCLING-PRODUCTS Table of contents
Project number: ZC133238545 Doc. no.: 508627696_EN_0 for
Project description: Recycling Products Status: Final .PFSS_.300_FRAN.332.4.A / Combined
Customer: RECYCLING-STANDARD Customer Shredder FRX-2000
Customer project no.: doc. no.: MCC

Created Checked

Pages
Label/ Revision Document number Document number
Sheet number
Unit / Location / Funct. Description 1 Description 2 Description 3 Status
Description ANDRITZ customer

Rev.
date by date by

72 B.25A1.V5 / / HS Circuit Diagram Hydraulic Panel Reject Hatch 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
73 B.25A1.V6 / / HS Circuit diagram Hydraulic Panel Lock Pusher/Service Hatch 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
74 B.20A6.L1 / / LS Circuit diagram Greasing Unit Level Low 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
75 B.25A1.V7 / / HS Circuit diagram Hydraulic Panel Lock Reject Hatch 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
76 B.25E1-H1 / +B4I.MCC01 / M Circuit diagram Hydraulic Heater MCC 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
77 B.25F1-M1 / +B4I.MCC01 / M Circuit diagram Hydraulic Cooler MCC 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
78 B.25P1-M1 / +B4I.MCC01 / M Circuit diagram Hydraulic Pump MCC 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
79 B.30H1-M1 / / M Circuit diagram Discharge Conveyor 1 MCC 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
80 B.30H1.S1 / +B4I.MCC01 / SS Circuit diagram Discharge Conveyor 1 Speed Low 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final 508627696_EN_0
Terminal Diagrams
81 / +B4I.CB01 / Terminal diagram - X41 MCC Local Control Panel 1 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final
82 / +B4I.CB01 / Terminal diagram - X61 MCC Local Control Panel 1 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final
83 / +B4I.CB01 / Terminal diagram - X10 MCC Local Control Panel 1 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final
84 / +B4I.CB02 / Terminal diagram - X61 MCC Local Control Panel 2 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final
85 / +B4I.CB02 / Terminal diagram - X10 MCC Local Control Panel 2 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final
86 / +B4I.CB02 / Terminal diagram - X71 MCC Local Control Panel 2 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final
87 / +B4I.JB01 / Terminal diagram - X61 Machine Junction Box 2 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final
89 / +B4I.JB01 / Terminal diagram - X81 Machine Junction Box 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final
90 / +B4I.JB05 / Terminal diagram - X21 Machine JB Slip Montoring 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final
91 / +B4I.JB05 / Terminal diagram - X61 Machine JB Slip Montoring 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final
92 / +B4I.JB05 / Terminal diagram - X62 Machine JB Slip Montoring 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final
93 / +B4I.JB10 / Terminal diagram - X61 Machine JB Condition Monitoring 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final
94 / +B4I.JB10 / Terminal diagram - X81 Machine JB Condition Monitoring 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final
95 / +B4I.JB10 / Terminal diagram - X82 Machine JB Condition Monitoring 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final
96 / +B4I.JB02 / Terminal diagram - X21 Hydraulic Panel Junction Box 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final
97 / +B4I.JB02 / Terminal diagram - X61 Hydraulic Panel Junction Box 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final
98 / +B4I.JB02 / Terminal diagram - X71 Hydraulic Panel Junction Box 2 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final
100 / +B4I.JB02 / Terminal diagram - X91 Hydraulic Panel Junction Box 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final
101 / +B4I.MCC01 / Terminal diagram - MC-X11 MCC Cabinet Terminals 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final
102 / +B4I.MCC01 / Terminal diagram - X4-M MCC Cabinet Terminals 2 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final
104 / +B4I.MCC01 / Terminal diagram - X4-P1 MCC Cabinet Terminals 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final
105 / +B4I.MCC01 / Terminal diagram - X4-P2 MCC Cabinet Terminals 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final
106 / +B4I.MCC01 / Terminal diagram - X4-P3 MCC Cabinet Terminals 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final
107 / +B4I.MCC01 / Terminal diagram - X4-P4 MCC Cabinet Terminals 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final
108 / +B4I.MCC01 / Terminal diagram - X4-P5 MCC Cabinet Terminals 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final
109 / +B4I.MCC01 / Terminal diagram - X41-CP01 MCC Cabinet Terminals 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final

Rev. Rev.Date Created Checked Description of Revision Creation date: 05.03.2020


Created: Prettner
Checked: Pereira-Perez / 05.03.2020
Page: / Of: 3 /133 5 /133
16:42:12
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will
neither copy, reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|MCC01|PAB.3 Date of print: 30.03.2020
Project name: RECYCLING-PRODUCTS Table of contents
Project number: ZC133238545 Doc. no.: 508627696_EN_0 for
Project description: Recycling Products Status: Final .PFSS_.300_FRAN.332.4.A / Combined
Customer: RECYCLING-STANDARD Customer Shredder FRX-2000
Customer project no.: doc. no.: MCC

Created Checked

Pages
Label/ Revision Document number Document number
Sheet number
Unit / Location / Funct. Description 1 Description 2 Description 3 Status
Description ANDRITZ customer

Rev.
date by date by

110 / +B4I.MCC01 / Terminal diagram - X10 MCC Cabinet Terminals 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final
111 / +B4I.MCC01 / Terminal diagram - X11 MCC Cabinet Terminals 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final
112 / +B4I.MCC01 / Terminal diagram - X0 MCC Cabinet Terminals 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final
113 / +B4I.MCC01 / Terminal diagram - X21 MCC Cabinet Terminals 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final
114 / +B4I.MCC01 / Terminal diagram - X21-JB05 MCC Cabinet Terminals 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final
115 / +B4I.MCC01 / Terminal diagram - X61-CP01 MCC Cabinet Terminals 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final
116 / +B4I.MCC01 / Terminal diagram - X61-CP02 MCC Cabinet Terminals 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final
117 / +B4I.MCC01 / Terminal diagram - X61-JB01 MCC Cabinet Terminals 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final
118 / +B4I.MCC01 / Terminal diagram - X61-JB02 MCC Cabinet Terminals 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final
119 / +B4I.MCC01 / Terminal diagram - X61-JB05 MCC Cabinet Terminals 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final
120 / +B4I.MCC01 / Terminal diagram - X62-JB01 MCC Cabinet Terminals 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final
121 / +B4I.MCC01 / Terminal diagram - X63-JB01 MCC Cabinet Terminals 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final
122 / +B4I.MCC01 / Terminal diagram - X70 MCC Cabinet Terminals 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final
123 / +B4I.MCC01 / Terminal diagram - X71-JB02 MCC Cabinet Terminals 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final
124 / +B4I.MCC01 / Terminal diagram - X71-CP02 MCC Cabinet Terminals 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final
125 / +B4I.MCC01 / Terminal diagram - X72-JB02 MCC Cabinet Terminals 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final
126 / +B4I.MCC01 / Terminal diagram - X81-JB01 MCC Cabinet Terminals 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final
127 / +B4I.MCC01 / Terminal diagram - X81-JB10 MCC Cabinet Terminals 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final
128 / +B4I.MCC01 / Terminal diagram - X82-JB10 MCC Cabinet Terminals 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final
129 / +B4I.MCC01 / Terminal diagram - X91 MCC Cabinet Terminals 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final
130 B.25F1-M1 / +B4I.MCC01 / M Terminal diagram - X1 Hydraulic Cooler MCC 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final
131 B.25P1-M1 / +B4I.MCC01 / M Terminal diagram - X1 Hydraulic Pump MCC 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final
132 B.30H1-M1 / / M Terminal diagram - X1 Discharge Conveyor 1 MCC 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final
133 B.30H1-M1 / / M Terminal diagram - X2 Discharge Conveyor 1 MCC 1 05.03.2020 Prettner 0 05.03.2020 Pereira-Perez Revision Final

Rev. Rev.Date Created Checked Description of Revision Creation date: 05.03.2020


Created: Prettner
Checked: Pereira-Perez / 05.03.2020
Page: / Of: 4 /133 6 /133
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.A|PED.7 Final date of print: 30.03.2020

16:43:17
third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates.
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting
receipt of this drawing does so on the express understanding and agreement that it will neither copy, reproduce, disclose to

IMPORTANT NOTES:

Machine housing, gearbox, drive and local control boxes or junction boxes,
made of metal, have to be connected to
Machine - schematic
- protective earth (PE)
- foundation earth, functional earth (TE, FE)
- equipotential bonding

Take special care of electrical installation and safety regulations


in accordance to local distribution system and local authority !

JB05 JB01

Also provide pipes for the connection


to the MCC Cabinet! (e.g. motors)
Drives
CB02 CB01

JB02 JB10

PE
min. 16mm²

min. 16mm²
16m
m² Hydraulic min. 120mm²
min.
Unit

schematic drawing only -


M=1:1
variations in actual positioning of components are possible

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Shredder Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner Shredder FRX-2000 Project no.: Location: +B4I
Checked: Pereira-Perez / 05.03.2020 Machine - Layout drawing and earthing - schematic Customer: RECYCLING-STANDARD Page: 7 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|CB01|0|PED.8 Final date of print: 30.03.2020

16:43:19
third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates.
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting
receipt of this drawing does so on the express understanding and agreement that it will neither copy, reproduce, disclose to

Front view Side View Inner Layout

+B4I.CB016-A3

+C4I-AF3
-TP1

-AF2
B.00A02.H7-SF

-X10
OPERATION SERVICE AUTOMATIC PUSHER
CONTROL
MODE MODE OPERATION
VOLTAGE
B.00A02.H4-S2

B.00A02.H6-S1
B.00A02.H4-S1
B.00A02.H2-S1

B.20A2.H1-S1
MAN AUT REM OFF ON STOP 0 START REV 0 FWD
ON
. S11 . S12 . S17 . S20
. S10

B.00A02.H1-S1
CONTROL SERVICE ROTOR FAULT
VOLTAGE
B.00A02.H3-S1
B.00A02.H2-S2

B.20A3.H1-S1

B.20A1.H2-S1

OFF CLOSE 0 OPEN REV 0 FWD RESET


. S13 . S21 . S22 . S25

-X41
-X61
+B4I.CB01
60 60 60

Conduit Gland:
2 X M25
3 x M16

PEDESTAL TO BE SUPPLIED LOOSE.


DO NOT MOUNT OR MAKE PREPARATION
ON CABINET.

M=1:5

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 MCC Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner Local Control Panel 1 Project no.: Location: +B4I.CB01
Checked: Pereira-Perez / 05.03.2020 Layout - Design plan A3 Customer: RECYCLING-STANDARD Page: 8 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|CB02|0|PED.9 Final date of print: 30.03.2020

16:43:23
third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates.
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting
receipt of this drawing does so on the express understanding and agreement that it will neither copy, reproduce, disclose to

Front View Inner Layout

REJECT HATCH PUSHER

B.20A4.G3-H1

B.20A2.H2-S1
LOCKED REV 0 FWD
. S28 . S29
B.00A02.H1-S2
300

SCREEN REJECT ROTOR


B.20A5.H1-S1

B.20A4.H1-S1

B.20A1.H3-S1
CLOSE 0 OPEN CLOSE 0 OPEN REV 0 FWD
. S30 . S31 . S32

-X71

-X61

-X10
+B4I.CB02

300

RITTAL
AE 1003.600
Conduit Gland:
3x M16
1 x M20

M=1:3

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 MCC Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner Local Control Panel 2 Project no.: Location: +B4I.CB02
Checked: Pereira-Perez / 05.03.2020 Layout - Design plan A3 Customer: RECYCLING-STANDARD Page: 9 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.A|JB01|0|PED.10 Final date of print: 30.03.2020

16:43:26
third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates.
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting
receipt of this drawing does so on the express understanding and agreement that it will neither copy, reproduce, disclose to

Front View Inner Layout

400

-X61
300

-X81

+B4I.JB01

35 45 25 25 25 25 25 25 25 25 25 25 25 25

0 6 6 6 6 6 KL 1508.510
ø2 ø1 ø1 ø1 ø1 ø1
25
35

Conduit Gland:
57

0 6 6 6 6 6 6 16 x M16
80

ø2 ø1 ø1 ø1 ø1 ø1 ø1
89

3 x M20
120

0 6 6 6 6 6
ø2 ø1 ø1 ø1 ø1 ø1

M=1:3

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Machine Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner Junction Box Project no.: Location: +B4I.JB01
Checked: Pereira-Perez / 05.03.2020 Layout drawings - Design plan A3 Customer: RECYCLING-STANDARD Page: 10 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.A|JB05|0|PED.11 Final date of print: 30.03.2020

16:43:29
third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates.
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting
receipt of this drawing does so on the express understanding and agreement that it will neither copy, reproduce, disclose to

Front View Inner Layout

-TP -TP
ESC130 ESC130

-X21

-X61

-X62
+B4I.JB05

Install box with rubber


pads against vibration

RITTAL
KL 1507.510
Conduit Gland:
2 x M16
5 x M12
4 x M20

M=1:3

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Machine Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner JB Slip Montoring Project no.: Location: +B4I.JB05
Checked: Pereira-Perez / 05.03.2020 Layout drawings - Design plan A3 Customer: RECYCLING-STANDARD Page: 11 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.A|JB10|0|PED.12 Final date of print: 30.03.2020

16:43:31
third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates.
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting
receipt of this drawing does so on the express understanding and agreement that it will neither copy, reproduce, disclose to

Front View
Inner Layout
200

200

-X61

-X81

-X82
+B4I.JB10

25 30 30 30 45

5
35

ø2 Conduit Gland:
2 x M25
8 x M16
40
120

M=1:2

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Machine Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner JB Condition Monitoring Project no.: Location: +B4I.JB10
Checked: Pereira-Perez / 05.03.2020 Layout drawings - Design plan A3 Customer: RECYCLING-STANDARD Page: 12 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.H|JB02|0|PED.13 Final date of print: 30.03.2020

16:43:33
third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates.
Front View Inner Layout
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting
receipt of this drawing does so on the express understanding and agreement that it will neither copy, reproduce, disclose to

25
LxWxD 254x25x80

100
-X61

-X71
LxWxD 305x40x80

LxWxD 305x40x80

40
LxWxD 254x40x80
380

Protection Cover
and Sign

100
-X91

-XPE
-X71

-X21

40
LxWxD 254x40x80

50
+B4I.JB02

35 35 35 25 25 25 25 25 25 25 25 25 25

RITTAL
AE 1380.500
Conduit Gland:
17 x M16
210
154
145
122
100

3 x M20
90

6 6 6 6 6 6
ø1 ø1 ø1 ø1 ø1 ø1
0
ø2

6 6 6 6 6
ø1 ø1 ø1 ø1 ø1
0
ø2

0
ø2

6 6 6 6 6 6
ø1 ø1 ø1 ø1 ø1 ø1

M=1:3
Bottom View

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Hydraulic Panel Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner Junction Box Project no.: Location: +B4I.JB02
Checked: Pereira-Perez / 05.03.2020 Layout drawings - Design plan A3 Customer: RECYCLING-STANDARD Page: 13 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|MCC01|0|PED.14 Final date of print: 30.03.2020

16:43:35
third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates.
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting
receipt of this drawing does so on the express understanding and agreement that it will neither copy, reproduce, disclose to

+B4I.MCC03-EC2
+B4I.MCC03-EC1

MOTOR SWITCH

-TP2
MUST BE
SWITCHED OFF
DURING MAINTENANCE

MAIN E-STOP
MAIN
DRIVE RH DRIVE LH

+B4I.MCC02

+B4I.MCC03 +B4I.MCC01

B.00A02.H1-S3
B.20A1-M1+B.Local.20-FC1

B.20A1-M2+B.Local.20-FC2
AUXILLARY SWITCH MAIN SWITCH

+B4I.MCC02-FC1
+B4I.MCC03-EC2.1
+B4I.MCC03-EC1.1

M=1:10

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 MCC Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner MCC Cabinet Project no.: ZC133238545 Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 Layout drawings - Design plan A3 Customer: RECYCLING-STANDARD Page: 14 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting
receipt of this drawing does so on the express understanding and agreement that it will neither copy, reproduce, disclose to
third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates.

M=1:10

Rev. Rev.Date Created


Checked
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|MCC01|0|PED.15

VFD Cabinet

B.20A1-M1-TA1
+B4I.MCC03

Description of Revision
Created:
+B4I.MCC03-EZ3

Checked:
Standard:
975,45

Crea.Date:
B.20A1-M2-TA2

Prettner

EN 60617
05.03.2020

Pereira-Perez / 05.03.2020
-BT2

B.25F1-M1-X1
+B4I.MCC01
MCC Cabinet

B.25P1-M1-X1 -FC3
B.30H1-M1-X1 B.20A1-M1.Local.20-FC1 B.25P1-M1-QA1
B.30H1-M1-X2
B.25F1-M1-QA1
B.30H1-M1-X11
+C4I.MCC02-1L1

+C4I.MCC02-1L3
+C4I.MCC02-1L2

-X0 B.30H1-M1-FC1

MCC
B.20A1-M2.Local.20-FC2
+B4I.MCC02-EZ2

power cables

power cables
B.30H1-M1-QA3

MCC Cabinet
B.30H1-M1.MCC02-TA1
power cables .MCC02-FC1
-N

-PE

Layout drawings - Design plan A3


B.00A02.X11-KF1
B.00A01.X1-KF1
-X71-CP02
-X61-CP02
-X61-CP01
-X41-CP01

-X70
-MC-X11

B.00A01.X1-KF2
B.00A01.X1-KF3 -BT1
B.00A01.X1-KF4
+B4I.MCC01

-TB1
C-Rail
MCC Cabinet

B.25A1.V1-KF1 -A01-01
.MCC02-FC2
B.25A1.V1-KF2
-A01-02 -TB2
B.20A6.X1-QA1 -A01-10 -FC11
-A01-11
-A01-20
-FC100 -FC12
Protection cover

B.00A01.X2-FQ1 -A01-30
Order:

-A01-31
-X62-JB01
-X61-JB01

-A01-32
-X81-JB01
-X63-JB01

-FC13
-X10

Project:

-A01-33
-A01-34 -FC14
Customer:

-A01-35
-EZ1

684

-A01-36
-A01-40 -FC15
-X4-M -A01-41
-A01-50
-A01-51
-A01-52 -A02-02
-X4-P1 -A01-60
-A01-70
-A01-80
-X72-JB02
-X71-JB02
-X61-JB02

-X91

-X11
-X21-JB05

-X21
-X82-JB10
-X81-JB10

-X4-P2
-X61-JB05

-X4-P3 -A02-03 -A06


-PE1 -X4-P4
-A02-04
-X4-P5 -A070
-A07
Project no.: ZC133238545

-EB1
-A03
-A04
RECYCLING-PRODUCTS Function

630 200 202,5 200 200,5


RECYCLING-STANDARD
Shield-Bar

Unit:

Page:
Final

15 / 133
Location: +B4I.MCC01

Draw. no.: 508627696_EN_0


date of print: 30.03.2020

16:43:37
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|MCC01|0|PED.16 Final date of print: 30.03.2020

16:43:44
third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates.
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting
receipt of this drawing does so on the express understanding and agreement that it will neither copy, reproduce, disclose to

MOTOR SWITCH
MUST BE
SWITCHED OFF
DURING MAINTENANCE

MAIN SWITCH MAIN MAIN


DRIVE RH DRIVE LH

M=1:1

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 MCC Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner MCC Cabinet Project no.: ZC133238545 Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 Layout drawings - Design plan A3 Customer: RECYCLING-STANDARD Page: 16 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
16:43:46
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|MCC02|2|PFSS.17 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC02
Power Distribution -L1
(B4I.MCC01/18.1)
-L2
(B4I.MCC01/18.1)
-L3
(B4I.MCC01/18.1)
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

A A
-2L1
(B.20A1-M1B.Local.20/40.2)
-2L2
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

(B.20A1-M1B.Local.20/40.2)
-2L3
(B.20A1-M1B.Local.20/40.2)

-3L1
(B.30H1-M1/79.1)
-3L2
(B.30H1-M1/79.1)
-3L3
(B.30H1-M1/79.1)

YE -L1/230V
(B4I.MCC01/20.1)
YE -L2/230V
(B4I.MCC01/20.1)
YE -L3/230V
B (B4I.MCC01/20.1) B
YE -N/230V
(B4I.MCC01/20.1)
1 3 5 7 1 3 5 N
-FC2

20 A
-FC1 SIEMENS 2 4 6 N
I>> I>> I>> I>>
SIEMENS 5SY8620-7
3VA2580-5HL42-0AA0 2 4 6 8
320-800 A 1 2 3 4
800 A .MCC01-W21

Oelflex Classic 110 BK


5G2,5

1 3 5 N

-SF1
C C
3LD2003-1TL51 2 4 6 N

PE
1 2 3 4
.MCC01-W20 Mounting Plate
Oelflex Classic 110 BK
5G2,5

PE
Cabinet
expressly agreed to by ANDRITZ AG or one of its affiliates.

.MCC01-X0
1
2
3
4

PE

.MCC01-PE
?

D D

L1 L2 L3 N PE L1 L2 L3 N PE
3x400V AC 50Hz 3x400V AC 50Hz
TN-S TN-S

E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 MCC Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner Power Distribution Project no.: Location: +B4I.MCC02
Checked: Pereira-Perez / 05.03.2020 Power supply - Circuit diagram Customer: RECYCLING-STANDARD Page: 17 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:43:48
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|MCC01|4|PFSS.18 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC01
MCC Cabinet .MCC02-L1 .MCC02-L1
(B4I.MCC02/17.7) (B.25F1-M1/77.2)
.MCC02-L2 .MCC02-L2
(B4I.MCC02/17.7) (B.25F1-M1/77.2)
.MCC02-L3 .MCC02-L3
(B4I.MCC02/17.7) (B.25F1-M1/77.2)
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

A A
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

24V Fuse Block ok


1 3 5 13 21
ET200SP 8-DI ST
Ref.:
Label: -A01-30
-FC3 14 22
I>> I>> I>> Loc.:

?
SIEMENS
Sort: DI
3RV2011-1DA15 2 4 6
2.2-3.2 A I300.6
3A DI00A01X2_REDUND

PE
B B

7
-TB1 -TB2

DI6
1 2 3 PE

SIEMENS SIEMENS
6EP1436-2BA10 6EP1961-3BA01
480 W
20 A 12 14
24 V -FC100
(.2)
+ - + - 11

C C

-P1:1b
(19.3)
expressly agreed to by ANDRITZ AG or one of its affiliates.

-FC100 RST
+ + 0V 0V
SIEMENS SITOP
0 1
6EP1961-2BA21 select
10 A A
1 2 3 4 B

D 10 A 10 A 10 A 10 A (.7) D
FAULT

1 2 3 4 11 14 12

-P4:1a
(19.1)
-P3:1a
(19.1)
-P2:1a
(19.1)
-P1:1a
(19.1)
-M:1a
(19.1)
E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 MCC Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner MCC Cabinet Project no.: ZC133238545 Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 Control voltage 24VDC - Supply Customer: RECYCLING-STANDARD Page: 18 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:43:50
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|MCC01|4|PFSS.19 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC01
MCC Cabinet -P4:1a
(18.4)
-P3:1a
(18.4)
-P2:1a
(18.4)
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

-P1:1a
A (18.4) 13 A
B.00A01.X2-FQ1
-M:1a
(18.4) (B.00A01.X2/22.2)
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

14
-X4-M
1a -M:1b -X4-P1 -X4-P2 -X4-P3 -X4-P4
(B.20A1-M1B.Local.20/40.3)
1b -M:1c 1a -P1:1b 1a -P2:1b 1a -P3:1b 1a -P4:1b
(26.1) (18.7) (26.1) (27.3) (B.25A1.L1/67.3)
1c -M:1d 1b -P1:1c 1b -P2:1c 1b -P3:1c 1b -P4:1c
(26.4) (B.20A1-M1B.Local.20/40.3) (26.4) (B.25A1.V5/72.2) (B.25A1.V1/69.6)
1d 1c -P1:1d 1c -P2:1d 1c -P3:1d 1c -P4:1d
(B.20A1-M2B.Local.20/41.3) (B.20A1.G1B4I.JB05/42.2) ? (B.25A1.V2/70.1)
-M:2a 1d 1d 1d 1d
(27.3)
2a -M:2b -P1:2a -P2:2a -P3:2a -P4:2a
? (.3) (B4I.CB016/24.2) (B.25A1.V1/69.1) ?
2b -M:2c 2a -P1:2b 2a -P2:2b 2a -P3:2b 2a -P4:2b
(B.25F1-M1/77.6) ? (27.5) ? ?
2c -M:2d 2b -P1:2c 2b -P2:2c 2b -P3:2c 2b -P4:2c
(B.20A1-M2B.Local.20/41.3) ? (25.2) ? ?
2d 2c -P1:2d 2c -P2:2d 2c -P3:2d 2c -P4:2d
? (28.1) ? (29.2)
-M:3a 2d 2d 2d 2d
B (B.20A1.S1/46.3) B
3a -M:3b -P1:3a -P2:3a -P4:3a
? ? (28.3) (29.4)
3b -M:3c 3a -P1:3b 3a -P2:3b 3a -P4:3b
(B.25A1.V2/70.1) ? (28.4) (29.1)
3c -M:3d 3b -P1:3c 3b -P2:3c 3b -P4:3c
? (B.20A1.S1/46.3) ? (29.4)
3d 3c -P1:3d 3c -P2:3d 3c -P4:3d
? ? ?
-M:4a 3d 3d 3d
(25.2)
4a -M:4b -P1:4a
(B.20A6.X1/66.2) (B.00A01.X1/31.2)
4b -M:4c 4a -P1:4b
(B.20A2.G1/52.3) (B.00A02.H2B4I.CB01/34.2)
4c -M:4d 4b -P1:4c
? (B.00A02.X11/38.4)
4d 4c -P1:4d
(B.20A2.G1/52.3)
-M:5a 4d
?
5a -M:5b
(B.00A02.H2B4I.CB01/34.5) 5a
5b -M:5c -P1:5a
(B.00A01.X1/33.1) 5b (B.25F1-M1/77.4)
5c -M:5d -P1:5b
? 5c (B.25P1-M1/78.4)
5d -P1:5c
C 5d (B.10B1.L1/39.3) C
-M:6a -P1:5d
? (B.20A3.G2/57.4)
6a -M:6b
(B.10B1.L1/39.3) 6a
6b -M:6c -P1:6a
(B.00A02.X11/38.3) 6b ?
6c -M:6d -P1:6b
(B.20A3.G2/57.4) 6c ?
6d -P1:6c
7a 6d (B.20A6.X1/66.2)
-M:7a -P1:6d
7b (B.25A1.L1/67.3) (B.20A4.H1B4I.CB02/63.2)
-M:7b
7c (29.1) 7a
-M:7c -P1:7a
(B.25A1.V1/69.6) (B.20A6.X1/66.4)
expressly agreed to by ANDRITZ AG or one of its affiliates.

7d -M:7d 7b -P1:7b
(29.2) 7c (26.1)
-P1:7c
8a 7d ?
-M:8a -P1:7d
8b (B4I.CB016/24.2) ?
-M:8b
8c (B.00A02.X11/38.4)
-M:8c
8d (B.25A1.V1/69.1)
-M:8d
D (29.4) D
9a -M:9a
9b (28.1)
-M:9b
9c (28.3)
-M:9c
9d (28.4)
-M:9d
(27.5)
10a -M:10a
10b (26.1)
-M:10b
10c (B.20A4.G3/62.7)
-M:10c
10d (29.4)
-M:10d
?
0V DC Common Supply 24V DC Power Supply PLC Power Supply 24V DC via Common Supply 24V DC
Emergency Stop
E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 MCC Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner MCC Cabinet Project no.: ZC133238545 Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 Control voltage 24VDC - Distribution Customer: RECYCLING-STANDARD Page: 19 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:43:55
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|MCC01|5|PFSS.20 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC02
Power Distribution

-L1/230V -L1/230V
(B4I.MCC02/17.7) (B4I.MCC03/21
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

-L2/230V -L2/230V
A (B4I.MCC02/17.7) ? A
-L3/230V -L3/230V
(B4I.MCC02/17.7) ?
-N/230V -N/230V
(B4I.MCC02/17.7) (B4I.MCC03/21
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

YE

YE
YE

YE

YE

YE

YE

YE
.MCC01-BT1

RITTAL
SK 3110.000

48V / 60V / N

L2* /250V / N
COOLING
HEATING

115V / N
24V / N
1 N 1 N 1 N 1 N

L1* / L
.MCC01-FC12 .MCC01-FC14 .MCC01-FC15
1 2 3 4 5 6 7
6A 6A 2A
.MCC01-FC11 SIEMENS 2 N SIEMENS 2 N SIEMENS 2 N
B 5SY6506-6 5SY6506-6 5SY6502-7 B
13 A / 30 mA T
SIEMENS 2 N
5SU1356-0KK13

YE

YE

YE

YE

YE

YE

YE
PE

PE

PE

PE
.MCC01-X21 .MCC01-X21-JB05

2
C C

GNYE

GNYE
1

2
+B4I.JB02-W21 +B4I.JB05-W11
GNYE

GNYE

GNYE
BN
BU

BN
BU

BN
BU

Oelflex Classic 110 BK Oelflex Classic 110 BK


.MCC01-EZ1-W01 -EZ2-W01 .MCC03-EZ3-W01 3G2,5 3G2,5

-X21:PE
Original Cable Original Cable Original Cable

-X21:1

-X21:2

-X21:1

-X21:2

-X21:3
3 x 1,5 3 x 1,5 3 x 1,5
expressly agreed to by ANDRITZ AG or one of its affiliates.

TPS L N PE L N PE TPS L N PE L N PE TPS L N PE L N PE L1

(B.25E1-H1/76.2)

(B.25E1-H1/76.2)

(B.25E1-H1/76.2)

(B.20A1.G1B4I.JB05/42.4)

(B.20A1.G1B4I.JB05/42.4)

(B.20A1.G1B4I.JB05/42.4)
.MCC01-EB1
PE
Auto 0 1 Auto 0 1 Auto 0 1
RITTAL
.MCC01-EZ1 -EZ2 .MCC03-EZ3 SK 3105.340
D D
N
RITTAL RITTAL RITTAL
SZ 2500.310 SZ 2500.310 SZ 2500.310

Cabinet light Cabinet light Cabinet light Cabinet Hydraulic Slip


with plug with plug with plug Heater Heater Monitoring RH
Cabinet 1 Cabinet 2 Cabinet 3
E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 MCC Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner MCC Cabinet Project no.: ZC133238545 Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 Common service - Cabinet light/heater Customer: RECYCLING-STANDARD Page: 20 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:43:57
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|MCC03|6|PFSS.21 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC03
VFD Cabinet

.MCC02-L1/230V .MCC02-L1/230V
(B4I.MCC01/20.7) ?
.MCC02-N/230V
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

.MCC02-N/230V
A (B4I.MCC01/20.7) ? A
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

YE

YE
-BT2

RITTAL
SK 3110.000

48V / 60V / N

L2* /250V / N
COOLING
HEATING

115V / N
24V / N
1 N

L1* / L
.MCC01-FC13
1 2 3 4 5 6 7
6A
SIEMENS 2 N
B 5SY6506-6 B

YE

YE

PE

PE
C C

YE

YE

YE
expressly agreed to by ANDRITZ AG or one of its affiliates.

L1 N PE L1 N PE

D M M D
1~ 1~
-EC1 -EC2

Fan Fan
Cooling 1 Cooling 2

E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 MCC Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner VFD Cabinet Project no.: Location: +B4I.MCC03
Checked: Pereira-Perez / 05.03.2020 Common service - Cabinet cooling Customer: RECYCLING-STANDARD Page: 21 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:43:58
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|00|A01|Z4|X2|PFSS.22 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC01
Safety Stop Command
MCC Cabinet
E-Stop = 0 E-Stop Feedback = 1 =0 Safety Stop Feedback = 0

ET200SP F 4DO, 2A PM HF ET200SP, F, 8-DI HF ET200SP F 4DO, 2A PM HF ET200SP, F, 8-DI HF


This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

Ref.: (26.4) Ref.: (26.3) Ref.: (26.4) Ref.: (26.3)


A Label: -A01-20 Label: -A01-11 Label: -A01-20 Label: -A01-11
A
Loc.: Loc.: Loc.: Loc.:
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

Sort: SRS-DO Sort: SRS-DI Sort: SRS-DO Sort: SRS-DI


Q24.0 I6.1 Q24.1 I6.3
DO00A01X2_ES DI00A01X2_FB_ES AI20A1M1_STS AI20A1M1_STF

10

10

12
DQ-P0

DQ-M0

DI1

VS1

DQ-P1

DQ-M1

DI3

VS3
B B
-FQ1
A1 A2 13 23 33 43 S51
SIEMENS
3SK1211-1BB40 1 S51 A1 A1 71
delayed / undelayed -FQ1 B.20A1-M1.Local.20-KF3
B.20A1-M1.Local.20-KF3 B.20A1-M1.Local.20-KF4
(.2) (.4)
S52 A2 A2 72
SIEMENS SIEMENS
14 24 34 44 S52
71
B.20A1-M1.Local.20-KF4
(.5)
72

C C

S51 S52 13 14 13 14
(.3) (B.20A1-M1B.Local.20/40.4)
(B.20A1-M1B.Local.20/40.4)
13 14 23 24 23 24
expressly agreed to by ANDRITZ AG or one of its affiliates.

(B4I.MCC01/19.5) (B.20A1-M2B.Local.20/41.4)
(B.20A1-M2B.Local.20/41.4)
23 24 33 34 33 34
? (B.30H1-M1/79.4) (B.30H1-M1/79.4)
33 34 43 44 43 44
? ? ?
43 44 53 54 53 54
? ? ?
61 62 61 62
? ?
71 72 71 72
(.6) (.6)
83 84 83 84
D ? ? D

E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 MCC Cabinet Project: RECYCLING-PRODUCTS Function Unit: B.00A01.X2
Created: Prettner MCC Signals Project no.: XS Location:
Checked: Pereira-Perez / 05.03.2020 ES extension Customer: RECYCLING-STANDARD Page: 22 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:44:00
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|00|A02|Z4|H1|PFSS.23 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC01
MCC Cabinet
E-Stop = 0 E-Stop = 0

ET200SP, F, 8-DI HF ET200SP, F, 8-DI HF


This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

Ref.: (26.2) Ref.: (26.2)


A Label: -A01-10 Label: -A01-10
A
Loc.: Loc.:
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

Sort: SRS-DI Sort: SRS-DI


I0.0 I0.4
DI00A02H1_S21 DI00A02H1_S22

13
DI0

VS0

DI4

VS4
B B

NOTE 1:

11

13

15

17

19
NOTE 1:
2

10

12

14

16

18

20
-X10
1

8
1

4
C B.00A02.H1-W61 B.00A02.H1-W62 -S3 11 21 C
Oelflex Classic 110 BK Oelflex Classic 110 BK E-Stop 3
5G1 5G1
12 22
+B4I.CB02 +B4I.CB01
Local Control Panel 2 -X10 Local Control Panel 1 -X10
1

4
E-Stop
Customer
(Option)
expressly agreed to by ANDRITZ AG or one of its affiliates.

D D
11 21
11 21
-S1
-S2
E-Stop 1 12 22
E-Stop 2 12 22

NOTE 1: Remove bridge in


case of a master SRS system.
1/2, 19/20 - E-Stops
3/4, 17/18 - Input PLC
E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Local Control Project: RECYCLING-PRODUCTS Function Unit: B.00A02.H1
Created: Prettner E-Stop Project no.: HSZ Location: +B4I.CB01
Checked: Pereira-Perez / 05.03.2020 Emergency Stop Customer: RECYCLING-STANDARD Page: 23 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:44:02
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|CB01|6|PFSS.24 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC01
MCC Cabinet
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

A A
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

-P2:2a
(B4I.MCC01/19.4)
-M:8a -A06:P12
(B4I.MCC01/19.2) (B4I.MCC01/29.4)

-X41-CP01

1
2
B B

Eth
1
2
+B4I.CB01-W41 +B4I.CB01-W51

Oelflex Classic 110 BK Ethernet Cable


3G1

+B4I.CB01
Local Control Panel 1 -X41
1
2
PE

-TP1 6-A3

WLAN Module
C USB U1 +C4I-AF3 C

+ 24VDC
0VDC
USB U2 PHOENIX CONTACT

PE

P1 RJ
CASSIA, X1000 FL WLAN 2101

-
DP/MPI

DP/MPI
-W53
Eth Ethernet Cable
L+ +24V
L- GND Address: -W54
Eth Ethernet Cable
-W52
expressly agreed to by ANDRITZ AG or one of its affiliates.

MPI/DP: 0 RJ45 E
Eth Ethernet Cable
PE Ethernet:192.168.0.50 RJ45 E
Subnet mask:
X5 X1 X2 X3 X4
TP900 Comfort 9" DP/PN
RJ-45 Ports

PE PE
D N 0V D
L +24V

PLANET
-AF2 IGS-614HPT
3

7
4

8
PE

PE
E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 MCC Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner Local Control Panel 1 Project no.: Location: +B4I.CB016
Checked: Pereira-Perez / 05.03.2020 PLC / HMI - HMI LCP Customer: RECYCLING-STANDARD Page: 24 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:44:03
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|MCC01|6|PFSS.25 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC01
MCC Cabinet
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

A A
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

-TP2

B B

RS232 RJ45 USB


1
SIEMENS
IPC277E

RS232 E
-W50
Eth Ethernet Cable

RJ45
. -A06:P5 (29.4)

E
192.168.0.51

-P2:2c

USB
C (19.4) +24V C

2
-M:4a
(19.2) 0V
expressly agreed to by ANDRITZ AG or one of its affiliates.

D D

E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 MCC Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner MCC Cabinet Project no.: ZC133238545 Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 PLC / HMI - HMI MCC Customer: RECYCLING-STANDARD Page: 25 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
E
B
A

D
C
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those
expressly agreed to by ANDRITZ AG or one of its affiliates.

1
1

(29.4)
MCC Cabinet
+B4I.MCC01

(19.2)
(19.3)
(19.2)
(19.4)

Rev. Rev.Date Created


-W59
Ethernet Cable
-A06:P9 Eth

-M:1c

-P1:7b
-P2:1b

-M:10a

Checked
RJ45

1L+ Address: 192.168.0.1 -A01-01


2L+
1M
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|MCC01|6|PFSS.26

Card:
2M
6ES7512-1SK01-0AB0

CPU FOR
ET 200SP
RJ45 RJ45

2
2

DP - Address: -A01-02

Description of Revision
RS485
Card:
6ES7545-5DA00-0AB0

ET 200SP
I0.0 (B.00A02.H1B4I.CB01/23.3) DI00A02H1_S21 E-Stop = 0

9
5
1

13

L+
5A
1A
I0.1 (B.20A3.G1/56.4) DI20A3G1_GSZ Service Hatch Closed = 1
-A01-10
I0.2 (B.20A5.G1/64.4) DI20A5G1_GSZ Screen Basket Closed = 1

6
2

M
14
10
Type: ET200SP, F, 8-DI HF

6A
2A
I0.3 (B.20A4.G1/60.4) DI20A4G1_GSZ Reject Hatch Closed = 1

Created:
Checked:
Standard:
Crea.Date:
I0.4 (B.00A02.H1B4I.CB01/23.4) DI00A02H1_S22 E-Stop = 0

7
3

15
11

9A
7A
3A
Card: 6ES7136-6BA00-0CA0 I0.5 (B.20A3.G1/56.4) DI20A3G1_GSZ.1 Service Hatch Closed = 1
Terminal: 6ES7193-6BP20-0DA0 I0.6 (B.20A5.G1/64.4) DI20A5G1_GSZ.1 Screen Basket Closed = 1

8
4

16
12

8A
4A

10A
I0.7 (B.20A4.G1/60.4) DI20A4G1_GSZ Reject Hatch Closed = 1

Prettner

3
3

I6.0 (B.20A1.H3B4I.CB02/45.4) DI20A1H3_S13 Local Start FWD = 1

9
5
1

EN 60617
13

L+
5A
1A

05.03.2020
I6.1 (B.00A01.X2/22.3) DI00A01X2_FB_ES E-Stop Feedback = 1
-A01-11
I6.2 (B.00A02.H7/30.3) DI00A02H7_S1 Maintenance Active = 0

Pereira-Perez / 05.03.2020
6
2

M
14
10
Type: ET200SP, F, 8-DI HF

6A
2A
I6.3 (B.00A01.X2/22.6) AI20A1M1_STF Safety Stop Feedback = 0
I6.4 (B.20A1.H3B4I.CB02/45.4) DI20A1H3_S14 Local Start REV = 1

7
3

15
11

9A
7A
3A
Card: 6ES7136-6BA00-0CA0 I6.5 (B.20A1.H3B4I.CB02/45.5) DI20A1H2_S15 Local Start = 1
Terminal: 6ES7193-6BP20-0BA0 I6.6 (B.00A02.H7/30.4) DI00A02H7_S1 Maintenance Active = 0

8
4

16
12

8A
4A

10A
I6.7 ?

(19.2)
(19.4)
Q24.0 (B.00A01.X2/22.2) DO00A01X2_ES E-Stop = 0

9
5
1

13

L+
5A
1A
Q24.1 (B.00A01.X2/22.4) AI20A1M1_STS Safety Stop Command = 0
-A01-20
Q24.2 ?
6
2

M
14
10
Type: ET200SP F 4DO, 2A PM HF

6A
2A
Q24.3 ?

-M:1d
-P2:1c
7
3

15
11

9A
7A
3A
Card: 6ES7136-6DB00-0CA0
Terminal: 6ES7193-6BP20-0BA0
8
4

16
12

8A
4A

10A

4
4

I300.0 (B.00A01.X1/31.2) DI00A01X1_ON_IN General On


9
5
1

13

L+
5A
1A

I300.1 (B.00A01.X1/31.2) DI00A01X1_STA_IN Auto Start


-A01-30
I300.2 (B.00A01.X1/31.3) DI00A01X1_STOP_IN Auto Stop
6
2

M
14
10

Type: ET200SP 8-DI ST


6A
2A

I300.3 (B.00A01.X1/31.4) DO00A01X1_DRU Discharge Running

MCC
I300.4 (B.00A01.X1/31.4) DI00A01X1_ES_IN Emergency Stop
7
3

15
11

9A
7A
3A

Card: 6ES7131-6BF01-0BA0 I300.5 (B.00A01.X1/31.5) DO00A01X1_SP Spare


Terminal: 6ES7193-6BP20-0DA0 I300.6 (18.7) DI00A01X2_REDUND 24V Fuse Block ok
8
4

16
12

8A
4A

10A

MCC Cabinet
I300.7 (B.00A02.H4B4I.CB01/36.5) DI00A02H4_S2 Service Mode = 1
I301.0 (B.00A02.H2B4I.CB01/34.3) DI00A02H2_S1 On=1
9
5
1

13

L+
5A
1A

I301.1 (B.00A02.H2B4I.CB01/34.3) DI00A02H2_S2 Off=0


-A01-31
I301.2 (B.00A02.H3B4I.CB01/35.3) DI00A02H3_S1 Reset=1
6
2

M
14
10

Type: ET200SP 8-DI ST


6A
2A

I301.3 (B.00A02.H4B4I.CB01/36.3) DI00A02H4_S11 Manual Mode=1


I301.4 (B.00A02.H4B4I.CB01/36.3) DI00A02H4_S12 Auto Mode=1
7
3

15
11

9A
7A
3A

Card: 6ES7131-6BF01-0BA0 I301.5 (B.00A02.H6B4I.CB01/37.4) DI00A02H6_S1 Auto Start Command = 1

5
5

PLC / HMI - ET200SP Overview


Terminal: 6ES7193-6BP20-0BA0 I301.6 (B.00A02.H6B4I.CB01/37.3) DI00A02H6_S2 Auto Stop Command = 1
8
4

16
12

8A
4A

10A

I301.7 (B.10B1.L1/39.4) DI10B1L1_LSH Level > High = 0


I302.0 (B.20A2.G1/52.4) DI20A2G1_GS Pusher in Rear Position = 1
9
5
1

13

L+
5A
1A

I302.1 (B.20A2.G2/53.4) DI20A2G2_GS Pusher in Front Position = 1


-A01-32
I302.2 (B.20A6.L1/74.4) DI20A6L1_LS Level Low = 0
6
2

M
14
10

Type: ET200SP 8-DI ST


6A
2A

I302.3 (B.20A6.X1/66.4) DI20A6X1_PLS Lubrication Pulse = 1


I302.4 (B.20A3.G2/57.4) DI20A3G2_GS Service Hatch Unlocked = 1
7
3

15
11

9A
7A
3A

Card: 6ES7131-6BF01-0BA0 I302.5 (B.20A1.H2B4I.CB01/44.4) DI20A1H2_S11 Local Start FWD = 1


Terminal: 6ES7193-6BP20-0BA0 I302.6 (B.20A1.H2B4I.CB01/44.3) DI20A1H2_S12 Local Start REV = 1
8
4

Order:
16
12

8A
4A

10A

I302.7 (B.25F1-M1/77.5) DI25F1M1_FBK Running Feedback = 1


Project:

Customer:

I303.0 (B.25F1-M1/77.4) DI25F1M1_RDY MCC Ready = 1


9
5
1

13

L+
5A
1A

I303.1 (B.20A2.H1B4I.CB01/54.4) DI20A2H1_S11 Local Command FWD = 1


-A01-33
I303.2 (B.20A2.H1B4I.CB01/54.3) DI20A2H1_S12 Local Command REV = 1
6
2

M
14
10

Type: ET200SP 8-DI ST


6A
2A

I303.3 (B.20A3.G3/58.4) DI20A3G3_GS Service Hatch Locked = 1


I303.4 (B.25A1.P1/68.4) DI25A1P1_PDS Press. > High = 0
7
3

15
11

9A
7A
3A

6
6

Card: 6ES7131-6BF01-0BA0 I303.5 (B.25P1-M1/78.5) DI25P1M1_FBK Running Feedback = 1


Terminal: 6ES7193-6BP20-0BA0 I303.6 (B.25P1-M1/78.4) DI25P1M1_RDY MCC Ready = 1
8
4

16
12

8A
4A

10A

Project no.: ZC133238545

I303.7 (B.20A4.G3/62.3) DI20A4G3_GS1 Reject Hatch Locked 1 = 1


I304.0 (B.30H1.S1/80.4) DI30H1S1_SS Speed Low = 0
9
5
1

13

L+
5A
1A

I304.1 (B.20A4.G2/61.3) DI20A4G2_GS1 Reject Hatch Unlocked 1 = 1


-A01-34
I304.2 (B.20A3.H1B4I.CB01/59.3) DI20A3H1_S11 Local Command Open = 1
RECYCLING-PRODUCTS Function
6
2

M
14
10

Type: ET200SP 8-DI ST


6A
2A

I304.3 (B.20A3.H1B4I.CB01/59.4) DI20A3H1_S12 Local Command Close = 1


I304.4 (B.20A4.H1B4I.CB02/63.4)
RECYCLING-STANDARD

DI20A4H1_S11 Local Command Open = 1


7
3

15
11

9A
7A
3A

Card: 6ES7131-6BF01-0BA0 I304.5 (B.20A4.H1B4I.CB02/63.3) DI20A4H1_S12 Local Command Close = 1


Terminal: 6ES7193-6BP20-0BA0 I304.6 (B.20A5.H1B4I.CB02/65.3) DI20A5H1_S11 Local Command Open = 1
Unit:
8
4

16
12

8A
4A

10A

Page:

I304.7 (B.20A5.H1B4I.CB02/65.4) DI20A5H1_S12 Local Command Close = 1


Final

7
7

26 / 133
Location: +B4I.MCC01

Draw. no.: 508627696_EN_0


16:44:04
date of print: 30.03.2020

E
B
A

D
C
E
B
A

D
C
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those
expressly agreed to by ANDRITZ AG or one of its affiliates.

1
1

MCC Cabinet
+B4I.MCC01

Rev. Rev.Date Created


I305.0 (B.25A1.L1/67.3) DI25A1L1_LSL Level < L = 0

9
5
1

13

L+
5A
1A
I305.1 (B.25A1.L1/67.4) DI25A1L1_LSLL Level < LL = 0
-A01-35
I305.2 (B.25A1.L1/67.5) DI25A1T1_TSH Temperature > H = 0

6
2

M
14
10
Type: ET200SP 8-DI ST

6A
2A

Checked
I305.3 (B.25A1.L1/67.5) DI25A1T1_TSHH Temperature > HH = 0
I305.4 ?

7
3

15
11

9A
7A
3A
Card: 6ES7131-6BF01-0BA0 I305.5 ?
Terminal: 6ES7193-6BP20-0BA0 I305.6 ?

8
4

16
12

8A
4A
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|MCC01|6|PFSS.27

10A
I305.7 ?
I306.0 (B.20A4.G3/62.5) DI20A4G2_GS2 Reject Hatch Locked 2 = 1

9
5
1

13

L+
5A
1A
I306.1 (B.20A4.G2/61.5) DI20A4G3_GS2 Reject Hatch Unlocked 2 = 1
-A01-36

2
2

I306.2 (B.20A1.G1B4I.JB05/42.4) DI20A1G1_GI Slip Monitoring RH = 1

6
2

M
14
10
Type: ET200SP 8-DI ST

6A
2A
I306.3 (B.20A1.G2B4I.JB05/43.4) DI20A1G2_GI Slip Monitoring LH = 1
I306.4 (B.20A2.H2B4I.CB02/55.3) DI20A2H2_S12 Local Command REV = 1

7
3

15
11

9A
7A
3A
Card: 6ES7131-6BF01-0BA0 I306.5 (B.20A2.H2B4I.CB02/55.4) DI20A2H2_S11 Local Command FWD = 1

Description of Revision
Terminal: 6ES7193-6BP20-0BA0 I306.6 ?

8
4

16
12

8A
4A

10A
I306.7 ?
Q300.0 (B.00A02.X11/38.3) DO00A02X11_HORN Horn Start Warning

9
5
1

13

L+
5A
1A
Q300.1 (B.00A01.X1/33.1) DO00A01X1_FLT Fault
-A01-40
Q300.2 (B.00A01.X1/33.2) DO00A01X1_ES_OUT Emergency Stop

6
2

(19.2)
(19.5)
M
14
10
Type: ET200SP 8-DO

6A
2A
Q300.3 (B.00A01.X1/33.2) DO00A01X1_ON_OUT General On
Q300.4 (B.00A01.X1/33.3) DO00A01X1_AUTO Auto Mode release

Created:
7
3

Checked:
15
11

Standard:
9A
7A
3A

Crea.Date:
Card: 6ES7132-6BF01-0BA0 Q300.5 (B.00A02.H2B4I.CB01/34.5) DO00A02H2_H1 Signal Lamp On

-M:2a
Terminal: 6ES7193-6BP20-0BA0 Q300.6 (B.00A02.H3B4I.CB01/35.5)

-P3:1b
DO00A02H3_H1 Signal Lamp Fault

8
4

16
12

8A
4A

10A
Q300.7 (B.20A4.G3/62.6) DO20A4G3_LCK Reject hatch locked
Q301.0 (B.25F1-M1/77.6) DO25F1M1_CO Command Start = 1

9
5
1

13

L+
5A
1A

Prettner

3
3

Q301.1 (B.25P1-M1/78.6) DO25P1M1_CO Command Start = 1

EN 60617
-A01-41

05.03.2020
Q301.2 (B.20A6.X1/66.3) DO20A6X1_CO Command Start = 1

6
2

M
14
10
Type: ET200SP 8-DO

6A
2A
Q301.3 (B.00A02.X12B4I.LCP01/32.3) DO00A01X11_CO Feeding Released = 1

Pereira-Perez / 05.03.2020
Q301.4 (B.00A02.X12B4I.LCP01/32.4) DO00A01X12_CO Reversing Active = 1

7
3

15
11

9A
7A
3A
Card: 6ES7132-6BF01-0BA0 Q301.5 (B.00A02.X12B4I.LCP01/32.4) DO00A01X13_CO Fault Active = 1
Terminal: 6ES7193-6BP20-0DA0 Q301.6 (B.00A01.X1/33.4) DO00A01X1_AUTO Feed Release

8
4

16
12

8A
4A

10A
Q301.7 ?
Q310.0 (B.25A1.V6/73.4) DO25A1V6_OYA Lock Service Hatch = 1

9
5
1

1A
Q310.1 (B.25A1.V2/70.4) DO25A1V2_OYB Close Service Hatch = 1
-A01-50
6 Q310.2 (B.25A1.V2/70.3) DO25A1V2_OYA Open Service Hatch = 1
2

10
Type: RQ 4x120VDC-230VAC

2A
Q310.3 (B.25A1.V3/71.4) DO25A1V3_OYA Open Screen Basket = 1
7
3

11
3A
Card: 6ES7132-6HD01-0BB1
Terminal: 6ES7193-6BP20-0BB0
8
4

12
4A

4
4

Q311.0 (B.25A1.V3/71.3) DO25A1V3_OYB Close Screen Basket = 1


9
5
1

1A

Q311.1 (B.25A1.V6/73.3) DO25A1V6_OYB Lock Pusher = 1


-A01-51
Q311.2 (B.25A1.V5/72.3) DO25A1V5_OYB Close Reject Hatch = 1
6
2

10

Type: RQ 4x120VDC-230VAC
2A

Q311.3 (B.25A1.V5/72.4) DO25A1V5_OYA Open Reject Hatch = 1


7
3

11
3A

MCC
Card: 6ES7132-6HD01-0BB1
Terminal: 6ES7193-6BP20-0BB0
8
4

12
4A

MCC Cabinet
Q312.0 (B.25A1.V1/69.2) DO25A1V1_OYB Pusher FWD Command = 1
9
5
1

1A

Q312.1 (B.25A1.V1/69.3) DO25A1V1_OYA Pusher REV Command = 1


-A01-52
Q312.2 (B.25A1.V7/75.3) DO25A1V7_OYA Release Reject Hatch = 1
6
2

(19.2)
(19.4)
10

Type: RQ 4x120VDC-230VAC
2A

Q312.3 (B.25A1.V7/75.4) DO25A1V7_OYB Lock Reject Hatch = 1


7
3

11
3A

Card: 6ES7132-6HD01-0BB1
-M:9d

Terminal: 6ES7193-6BP20-0BB0
-P2:2b
8
4

12
4A

5
5

PLC / HMI - ET200SP Overview


IW1500 (B.20A1.T1/47.4) AI20A1T1_TT Actual Temperature
9
5
1

13

L+
5A
1A

IW1502 (B.20A1.T2/48.4) AI20A1T2_TT Actual Temperature


-A01-60
6
2

M
14
10

Type: ET200SP, I 2/4 WIRE, 2AI ST


6A
2A
7
3

15
11

9A
7A
3A

Card: 6ES7134-6GB00-0BA1
Terminal: 6ES7193-6BP20-0DA0
8
4

16
12

8A
4A

10A

Order:

QW1500 (B.25A1.V1/69.6) AO25A1V1_OY Closing Pressure


Project:
9
5
1

13

L+
5A
1A

Customer:

QW1502 ?
-A01-70
6
2

M
14
10

Type: ET200SP, 2AO, 2xI ST


6A
2A
7
3

15
11

9A
7A
3A

Card: 6ES7135-6GB00-0BA1
6
6

Terminal: 6ES7193-6BP20-0BA0
8
4

16
12

8A
4A

10A

Project no.: ZC133238545

I318.0 (B.20A1.S1/46.3) DI20A1S1_SE Pulse of Incremental


9
5
1

13

L+
5A
1A

I318.1 ?
-A01-80
I318.2 ?
6
2

M
14
10

Type: ET200SP, 1 Count 24VDC


6A
2A

I318.3 ?
RECYCLING-PRODUCTS Function

I318.4 ?
7
3

15
11

9A
7A
3A

Card: 6ES7138-6AA00-0BA0 I318.5 ?


RECYCLING-STANDARD

Terminal: 6ES7193-6BP20-0BA0
8
4

16
12

8A
4A

10A

Unit:

Page:
Final

7
7

27 / 133
Location: +B4I.MCC01

Draw. no.: 508627696_EN_0


16:44:07
date of print: 30.03.2020

E
B
A

D
C
16:44:10
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|MCC01|6|PFSS.28 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC01
MCC Cabinet
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

A Label: -A02-02 Label: -A02-03 Label: -A02-04


A
Location: Location: Location:
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

Unit: Unit: Unit:


Type: 6ES7 215-1HG40-0XB0 Type: 6AT8007-1AA10-0AA0 Type: 6AT8007-1AA10-0AA0
Sort: CPU 1214C Sort: SM1281 Sort: SM1281
Terminal

Terminal

Terminal

Terminal
Channel

Channel

Channel

Channel
Address

Address

Address

Address
X10 X12 X11 X11
? .0 a.0 K01 K17 a.0 .0 ? 1+ 1+
(B.20A1.V1/49.3) 1 VIB1 (B.20A1.V2/50.4) 1 VIB1
? .1 a.1 K02 K18 a.1 .1 ? 1- 1-
? .2 a.2 K03 K19 a.2 .2 ? 2+ 2+
(B.20A1.V1/49.4) 2 VIB2 (B.20A1.V3/51.4) 2 VIB2
? .3 a.3 K04 K20 a.3 .3 ? 2- 2-
? .4 a.4 K05 K21 a.4 .4 ? 3+ 3+
B ? .5 a.5 K06 K22 a.5 .5 ?
(B.20A1.V1/49.5) 3
3-
VIB3 ? 3
3-
VIB3 B
? .6 a.6 K07 K23 a.6 .6 ? 4+ 4+
? 4 VIB4 ? 4 VIB4
? .7 a.7 K08 K24 a.7 .7 ? 4- 4-
? .0 b.0 K09 K25 b.0 .0 ? X10 X10
? .1 b.1 K10 K26 b.1 .1 ? IN IN
? .2 b.2 K11 (B.20A1.S1/46.4) S P (B.20A1.S1/46.5) S P
RPM RPM
? .3 b.3 K12 DI20A1S1_SE 0 DI20A1S1_SE 0
? .4 b.4 K13
? .5 b.5 K14
X11
? 0 0 K15
? 1 1 K16

C C
expressly agreed to by ANDRITZ AG or one of its affiliates.

PROFINET:192.168.0.2

PROFINET:
PROFINET:

PROFINET:
PROFINET:
D D
X10 X11 X12 X1 X10 X1 X2 X10 X1 X2
L+ M PE L+ M 1M 2M 1L 2L P1 L+ M PE P1 P1 L+ M PE P1 P1

-P2:3b
-P2:2d -P2:3a (19.4)
(19.4) (19.4) -M:9c
-M:9a -M:9b (19.2)
(19.2) (19.2)
Eth

Eth

Eth
-W51 -W52 -W53
Ethernet Cable Ethernet Cable Ethernet Cable
-A06:P6 (29.4)

E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 MCC Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner MCC Cabinet Project no.: ZC133238545 Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 PLC / HMI - S7-1200 Overview Customer: RECYCLING-STANDARD Page: 28 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:44:12
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|MCC01|6|PFSS.29 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC01
MCC Cabinet
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

A A
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

-A070

Broadband Antenna -W50


Eth Ethernet Cable -TP2:E
B&R (25.3)
0RMSM.AMB-10

-A03 -A07 -W53

ANTANT
Eth Ethernet Cable -A02-04:P1
(28.5)

Output 2 UPLINK1
DEV1
WLAN Module Site Manager

+ 24VDC
0VDC
PHOENIX CONTACT B&R -W58

PE

P1 RJ

+12-24V in
FL WLAN 2101 0RMSM1135.4G-EU Eth Ethernet Cable -TA2:ETH

Output 1b
Output 1a
(B.20A1-M2B.Local.20/41.4)

+5V out
Input 1
Input 2
-

GND

GND
PE
B Eth
-W57
Ethernet Cable
B
-TA1:ETH (B.20A1-M1B.Local.20/40.4)

-P4:2d -P4:3c
(19.6) (19.6) -W59

PE

PE
-M:7d -M:8d -PE Eth Ethernet Cable
-A01-01:RJ45
(19.2) (19.2) (26.2)

-W61
Eth Ethernet Cable -TA1:ETH
(B.30H1-M1/79.4)
-W56
Eth Ethernet Cable
.CB01-W51
Eth Ethernet Cable
-W54
-A04 Eth Ethernet Cable
B&R COM1
B&R -W55
Eth Ethernet Cable
5Y3D4040000060-XXX ETH1
C ETH2 C
-A06
P13P13P14P14 P1 P2 P3 P4 P5 P6 P7 P8 P9 P10P11P12
USB1

BFOC/MM IN

BFOC/MM IN
-P4:3b

BFOC/MM OUT

BFOC/MM OUT

RJ45 Port 1
RJ45 Port 2
RJ45 Port 3
RJ45 Port 4
RJ45 Port 5
RJ45 Port 6
RJ45 Port 7
RJ45 Port 8
RJ45 Port 9
RJ45 Port 10
RJ45 Port 11
RJ45 Port 12
(19.6) + 24V DC USB2
-M:7b
(19.2) - 0V DC USB3
PE USB4
USB5
PE

PHOENIX CONTACT
FL Switch 3012EE-2SFX
expressly agreed to by ANDRITZ AG or one of its affiliates.

DisplayPort

24VDC

24VDC

Fault 1
Fault 2
2891067

0VDC
0VDC
12x RJ45 2X BFC
Automation PC 910 DVI
L1+ M1 M2 L2+ F1 F2

-P4:3a
(19.6)
-M:10c
D (19.2) D

-AF2:X5
(B4I.CB016/24.4)
E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 MCC Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner MCC Cabinet Project no.: ZC133238545 Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 PLC / HMI - PC and Network Overview Customer: RECYCLING-STANDARD Page: 29 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:44:14
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|00|A02|Z4|H7|PFSS.30 As Built date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC01
MCC Cabinet
Maintenance Active = 0 Maintenance Active = 0

ET200SP, F, 8-DI HF ET200SP, F, 8-DI HF


This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

Ref.: (26.3) Ref.: (26.3)


A Label: -A01-11 Label: -A01-11
A
Loc.: Loc.:
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

Sort: SRS-DI Sort: SRS-DI


I6.2 I6.6
DI00A02H7_S1 DI00A02H7_S1

11

15
DI6

VS6
B B

22
23

24
25
-X61-CP01

22
23

24
25
C +B4I.CB01-W12 C
Oelflex Classic 110 BK
34G1

+B4I.CB01
22
23

24
25
Local Control Panel 1 -X61
expressly agreed to by ANDRITZ AG or one of its affiliates.

D D
L1 L2 L3
-SF
Main / control switch black, 7.5 kW, 16A
SIEMENS
T1 T2 T3
3LD2003-0TK51

E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 15.03.2020 Local Control Project: RECYCLING-PRODUCTS Function Unit: B.00A02.H7
Created: Maintenance Switch Project no.: SF Location:
Checked: / Maintenance Switch Customer: RECYCLING-STANDARD Page: 30 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:44:15
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|00|A01|Z4|X1|PFSS.31 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC01
MCC Cabinet
General On Auto Start Auto Stop Discharge Running Emergency Stop Spare

ET200SP 8-DI ST ET200SP 8-DI ST ET200SP 8-DI ST ET200SP 8-DI ST ET200SP 8-DI ST ET200SP 8-DI ST
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

Ref.: (26.4) Ref.: (26.4) Ref.: (26.4) Ref.: (26.4) Ref.: (26.4) Ref.: (26.4)
A Label: -A01-30 Label: -A01-30 Label: -A01-30 Label: -A01-30 Label: -A01-30 Label: -A01-30
A
Loc.: Loc.: Loc.: Loc.: Loc.: Loc.:
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

Sort: DI Sort: DI Sort: DI Sort: DI Sort: DI Sort: DI


I300.0 I300.1 I300.2 I300.3 I300.4 I300.5
DI00A01X1_ON_IN DI00A01X1_STA_IN DI00A01X1_STOP_IN DO00A01X1_DRU DI00A01X1_ES_IN DO00A01X1_SP

6
DI0

DI1

DI2

DI3

DI4

DI5
(19.3)
-P1:4a

B B

OG

OG

OG
-MC-X11
1

7
1

7
C +B4I.MCC01-W11 C
Oelflex Classic 110 BK
34G1

Customer
expressly agreed to by ANDRITZ AG or one of its affiliates.

24VDC to Main Controller

Emergency Stop Customer


Auto Start
General On

Auto Stop

Discharge Running

Spare
D D

E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 MCC Cabinet Project: RECYCLING-PRODUCTS Function Unit: B.00A01.X1
Created: Prettner Interface Main Controller Project no.: XS Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 Circuit diagram Customer: RECYCLING-STANDARD Page: 31 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:44:16
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|00|A02|Z4|X12|PFSS.32 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC01
Feeding Released Reversing Active
MCC Cabinet
=1 =1 Fault Active = 1

ET200SP 8-DO ET200SP 8-DO ET200SP 8-DO


This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

Ref.: (27.3) Ref.: (27.3) Ref.: (27.3)


A Label: -A01-41 Label: -A01-41 Label: -A01-41
A
Loc.: Loc.: Loc.:
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

Sort: DO Sort: DO Sort: DO


Q301.3 Q301.4 Q301.5
DO00A01X11_CO DO00A01X12_CO DO00A01X13_CO

6
DO3

DO4

DO5
19

20

21
-X61-CP01

B B

19

20

21
+B4I.CB01-W12

Oelflex Classic 110 BK


34G1

+B4I.CB01

19

20

21
Local Control Panel 1 -X61

(B.00A02.H3B4I.CB01/35.5) -S1:2

C C
+B4I.LCP01-X1 0 1 2 3

SIEMENS
8WD4408-0AB
expressly agreed to by ANDRITZ AG or one of its affiliates.

Green Yellow Red


SIEMENS SIEMENS SIEMENS
8WD4400-1AC 8WD4400-1AD 8WD4400-1AB

D D

E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Local Control Project: RECYCLING-PRODUCTS Function Unit: B.00A02.X12
Created: Prettner Local Status Indication Project no.: XI Location: +B4I.LCP01
Checked: Pereira-Perez / 05.03.2020 Signal Horn Customer: RECYCLING-STANDARD Page: 32 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:44:18
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|00|A01|Z4|X1|PFSS.33 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC01
MCC Cabinet
Fault Emergency Stop General On Auto Mode release Feed Release

ET200SP 8-DO ET200SP 8-DO ET200SP 8-DO ET200SP 8-DO ET200SP 8-DO
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

Ref.: (27.2) Ref.: (27.2) Ref.: (27.2) Ref.: (27.2) Ref.: (27.3)
A Label: -A01-40 Label: -A01-40 Label: -A01-40 Label: -A01-40 Label: -A01-41
OG OG OG A
Loc.: Loc.: Loc.: Loc.: Loc.:
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

Sort: DO Sort: DO Sort: DO Sort: DO Sort: DO


11 11
Q300.1 Q300.2 Q300.3 Q300.4 Q301.6 (.1) (.2) 20 11 11 11
DO00A01X1_FLT DO00A01X1_ES_OUT DO00A01X1_ON_OUT DO00A01X1_AUTO DO00A01X1_AUTO (.3) (.3)
-KF1 -KF2
B.20A1-M1.MCC03-TA1 -KF3 -KF4 -KF5
12 14 12 14
2

7
(B.20A1-M1B.Local.20/40.2) 18 19 12 14 12 14 (.4) 12 14
DO1

DO2

DO3

DO4

DO6

OG
20
A1 A1 A1 A1 A1
B.20A1-M2.MCC03-TA2
-KF1 -KF2 -KF3 -KF4 -KF5
(B.20A1-M2B.Local.20/41.2) 18 19
A2 A2 A2 A2 A2
PHOENIX CONTACT PHOENIX CONTACT PHOENIX CONTACT PHOENIX CONTACT PHOENIX CONTACT
B B

OG
PLC-RSC- 24DC/21 PLC-RSC- 24DC/21 PLC-RSC- 24DC/21 PLC-RSC- 24DC/21 PLC-RSC- 24DC/21

OG

OG
OG
-M:5c
(19.2)

OG

PE
10

11

12

13

14
-MC-X11

10

11

12

13

14
8

9
C +B4I.MCC01-W11 C
Oelflex Classic 110 BK
34G1

Customer
expressly agreed to by ANDRITZ AG or one of its affiliates.

Main Drive On

General On

Auto Mode release

Feeding release
24VDC from Main Controller

ES (no SRS)
Fault
D D

Signals
to Main Controller (MC)
14 14 14 14 14
11 11 11 11 11
(.4) 12 (.5) 12 (.6) 12 (.6) 12 (.7) 12

E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 MCC Cabinet Project: RECYCLING-PRODUCTS Function Unit: B.00A01.X1
Created: Prettner Interface Main Controller Project no.: XS Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 Circuit diagram Customer: RECYCLING-STANDARD Page: 33 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:44:19
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|00|A02|Z4|H2|PFSS.34 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC01
MCC Cabinet
On=1 Off=0 Signal Lamp On

ET200SP 8-DI ST ET200SP 8-DI ST ET200SP 8-DO


This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

Ref.: (26.5) Ref.: (26.5) Ref.: (27.2)


A Label: -A01-31 Label: -A01-31 Label: -A01-40
A
Loc.: Loc.: Loc.:
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

Sort: DI Sort: DI Sort: DO


I301.0 I301.1 Q300.5
DI00A02H2_S1 DI00A02H2_S2 DO00A02H2_H1

6
-P1:4b

DI0

DI1

DO5
(B4I.MCC01/19.3)
-M:5b
(B4I.MCC01/19.2)

-X61-CP01

5
B B

5
+B4I.CB01-W12

Oelflex Classic 110 BK


34G1

+B4I.CB01
Local Control Panel 1 -X61

5
-S1:13 (B.00A02.H3/35.3)
C C

-S1 13 -S2 11 Green 1


expressly agreed to by ANDRITZ AG or one of its affiliates.

-S1

14 12 2

-S1:2
D (B.00A02.H3/35.5) D

E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Local Control Project: RECYCLING-PRODUCTS Function Unit: B.00A02.H2
Created: Prettner Control Voltage On/Off Project no.: HS Location: +B4I.CB01
Checked: Pereira-Perez / 05.03.2020 Circuit diagram Customer: RECYCLING-STANDARD Page: 34 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:44:21
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|00|A02|Z4|H3|PFSS.35 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC01
MCC Cabinet
Reset=1 Signal Lamp Fault

ET200SP 8-DI ST ET200SP 8-DO


This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

Ref.: (26.5) Ref.: (27.2)


A Label: -A01-31 Label: -A01-40
A
Loc.: Loc.:
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

Sort: DI Sort: DO
I301.2 Q300.6
DI00A02H3_S1 DO00A02H3_H1

7
DI2

DO6
-X61-CP01

7
B B

7
+B4I.CB01-W12

Oelflex Classic 110 BK


34G1

+B4I.CB01
Local Control Panel 1 -X61

7
(B.00A02.H2/34.4) -S2:11 -S1:11 (B.00A02.H4/36.3)
C C

-S1 13 Blue 1
expressly agreed to by ANDRITZ AG or one of its affiliates.

-S1

14 2

D D
(B.00A02.H2/34.5) -S1:2 -X1:0 (B.00A02.X12B4I.LCP01/32.3)

E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Local Control Project: RECYCLING-PRODUCTS Function Unit: B.00A02.H3
Created: Prettner Indication / Reset / Fault Project no.: HS Location: +B4I.CB01
Checked: Pereira-Perez / 05.03.2020 Circuit diagram Customer: RECYCLING-STANDARD Page: 35 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:44:22
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|00|A02|Z4|H4|PFSS.36 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC01
MCC Cabinet
Manual Mode=1 Auto Mode=1 Service Mode = 1

ET200SP 8-DI ST ET200SP 8-DI ST ET200SP 8-DI ST


This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

Ref.: (26.5) Ref.: (26.5) Ref.: (26.4)


A Label: -A01-31 Label: -A01-31 Label: -A01-30
A
Loc.: Loc.: Loc.:
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

Sort: DI Sort: DI Sort: DI


I301.3 I301.4 I300.7
DI00A02H4_S11 DI00A02H4_S12 DI00A02H4_S2

8
DI3

DI4

DI7
10
-X61-CP01

9
B B

10
8

9
+B4I.CB01-W12

Oelflex Classic 110 BK


34G1

+B4I.CB01

10
Local Control Panel 1 -X61

9
(B.00A02.H3/35.3) -S1:13 -S1:13 (B.00A02.H6/37.3)
C C

-S1 11 21 -S2 13
102
expressly agreed to by ANDRITZ AG or one of its affiliates.

Operation Mode

SIEMENS 12 22 14
3SU1

D D

E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Local Control Project: RECYCLING-PRODUCTS Function Unit: B.00A02.H4
Created: Prettner Operation Mode Project no.: HS Location: +B4I.CB01
Checked: Pereira-Perez / 05.03.2020 Circuit diagram Customer: RECYCLING-STANDARD Page: 36 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:44:24
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|00|A02|Z4|H6|PFSS.37 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC01
Auto Stop Command Auto Start Command
MCC Cabinet
=1 =1

ET200SP 8-DI ST ET200SP 8-DI ST


This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

Ref.: (26.5) Ref.: (26.5)


A Label: -A01-31 Label: -A01-31
A
Loc.: Loc.:
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

Sort: DI Sort: DI
I301.6 I301.5
DI00A02H6_S2 DI00A02H6_S1

6
DI6

DI5
11

12
-X61-CP01

B B

11

12
+B4I.CB01-W12

Oelflex Classic 110 BK


34G1

+B4I.CB01

11

12
Local Control Panel 1 -X61

-S2:14 -S1:13
C (B.00A02.H4/36.5) (B.20A1.H2/44.4) C

13 23
102
expressly agreed to by ANDRITZ AG or one of its affiliates.

-S1

LH / RH Stop/Start 14 24

D D

E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Local Control Project: RECYCLING-PRODUCTS Function Unit: B.00A02.H6
Created: Prettner Automatic Start/Stop Project no.: HS Location: +B4I.CB01
Checked: Pereira-Perez / 05.03.2020 Circuit diagram Customer: RECYCLING-STANDARD Page: 37 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:44:25
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|00|A02|Z4|X11|PFSS.38 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC01
MCC Cabinet
Horn Start Warning

ET200SP 8-DO
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

Ref.: (27.2) -P1:4c


A (19.3) A
Label: -A01-40 -M:8b
Loc.:
(19.2)
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

Sort: DO
Q300.0
DO00A02X11_HORN

1
DO0
A1

-KF1
11
B A2 -KF1 B
PHOENIX CONTACT
PLC-RSC- 24DC/21 (.3)
12 14

-M:6c
(19.2)

-X70

2
1

2
C B.00A02.X11-W71 C
Oelflex Classic 110 BK
3G1

+B.Local.00
Customer
expressly agreed to by ANDRITZ AG or one of its affiliates.

1
-H1

2
D D

14
11
(.5) 12

E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Local Control Project: RECYCLING-PRODUCTS Function Unit: B.00A02.X11
Created: Prettner Signal Horn Project no.: XI Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 Circuit diagram Customer: RECYCLING-STANDARD Page: 38 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:44:26
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|10|B1|Z4|L1|PFSS.39 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC01
MCC Cabinet
Level > High = 0

ET200SP 8-DI ST
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

Ref.: (26.5)
A Label: -A01-31
A
Loc.:
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

Sort: DI
I301.7
DI10B1L1_LSH

8
-P1:5c

DI7
(19.3)
-M:6b
(19.2)

-X62-JB01

1
2
3

4
B B

1
2
3
4
+B4I.JB01-W62

Oelflex Classic 110 BK


12G1

+B4I.JB01

50
Junction Box -X61 -X61:54 (B.20A4.G1/60.4)

51
-X61:55 (B.20A4.G1/60.4)

52
53
1 2 3 4
C B.10B1.L1-W62 C
Oelflex Classic 110 BK
5G1

+B.Local.10
Feeding
expressly agreed to by ANDRITZ AG or one of its affiliates.

1 2
B.10B1.L1-W61
D Oelflex Classic 110 BK
D
L/+

N/-

5G1
4
3
5

-LS1 L/+ . -LS2


VEGA N/- . VEGA
MPT61.XXAGA1TKMX MPR61.XXAGA1RKMX

OPTION 1
E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Feeding Chute Project: RECYCLING-PRODUCTS Function Unit: B.10B1.L1
Created: Prettner Level High Project no.: LS Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 Circuit diagram Customer: RECYCLING-STANDARD Page: 39 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:44:28
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|20|A1|M1|E|PFSS.40 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC03
VFD Cabinet
.MCC02-2L1 .MCC02-2L1
(B4I.MCC02/17.7) (B.20A1-M2/41.2)
.MCC02-2L2 .MCC02-2L2
(B4I.MCC02/17.7) (B.20A1-M2/41.2)
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

.MCC02-2L3 .MCC02-2L3

(B4I.MCC01/19.3)

(B4I.MCC01/19.2)
A (B4I.MCC02/17.7) (B.20A1-M2/41.2) A
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

1 3 5 23 11 21 13 13 13
.Local.20-KF3 .Local.20-KF4
(B.00A01.X2/22.4) (B.00A01.X2/22.5)
.Local.20-FC1 24 12 22 14 14 14
I>> I>> I>>

(B.25A1.V2/70.2)

(.5)

.MCC01-P1:1c

.MCC01-M:1b
SIEMENS
3VA2440-5MN32-0AA0 2 4 6
100-400 A
270 A

-TA2:XD2D:1 (B.20A1-M2/41.2)
PE -TA2:XD2D:2
B (B.20A1-M2/41.2) B

Eth
Ethernet Cable -TA2:XD2D:3
.MCC01-W60 (B.20A1-M2/41.2)

Profinet Interface
-TA1 L1 L2 L3 PE 1 2 1 2 3 4 5 6 7 1 2 3 4 1 2 3 1 2 3 4 X205 X13 X12

SUPPLY

AO1

AO2

OUT1

IN1

IN2
+24VI

GND

AGND

AI1+

DI3+

AGND

AGND

BGND

SGND

Memory unit

Safety functions mod.


+VREF

-VREF

AI1-

AI2-

Control panel

FENA-21
XPOW XAI XAO XD2D XSTO

ABB
13
ACS880-01-430A-3+E200+K475+P904+Q973
.Local.20-FC1

Address:
(B.00A01.X1B4I.MCC01/33.5)
? ? XD24 XDI XDIO
R+/UDC+

XRO1 XRO2 XRO3

DIOGND
(B.Local.20.2)

DICOM

+24VD
UDC-

DIO1

DIO2
GND
C C

DIIL
14

DI1

DI2

DI3

DI4

DI5

DI6
PE

MOTOR

U V W PE 11 12 13 21 22 23 31 32 33 1 2 3 4 5 1 2 3 4 5 6 1 2 ETHETH

Eth
.MCC01-W57
-A06:P8 (B4I.MCC01/29.4)
Ethernet Cable
expressly agreed to by ANDRITZ AG or one of its affiliates.

Sh
.MCC01-X11
1
2
GNYE
GY
BN
BK

1
2

B.20A1-M1-W01 B.20A1-M1-W111
D NYCWY Oelflex Classic 110 BK CY
D
3 x 120 SM / 70 2x1
+B.Local.20
U1 V1 W1 PE
Schredder

M
3~ 1
ϑ ϑ ϑ
2

B.20A1-M1

Main Drive RH

160 kW
271 A
E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Shredder Project: RECYCLING-PRODUCTS Function Unit: B.20A1-M1
Created: Prettner MCC Project no.: M Location: +B.Local.20
Checked: Pereira-Perez / 05.03.2020 Cabinet diagram Power Customer: RECYCLING-STANDARD Page: 40 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:44:30
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|20|A1|M2|E|PFSS.41 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC03
VFD Cabinet
.MCC02-2L1
(B.20A1-M1/40.3)
.MCC02-2L2
(B.20A1-M1/40.3)
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

.MCC02-2L3

(B4I.MCC01/19.3)

(B4I.MCC01/19.2)
A (B.20A1-M1/40.3) A
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

1 3 5 23 11 21 13 23 23
B.20A1-M1.Local.20-KF3 B.20A1-M1.Local.20-KF4
(B.00A01.X2/22.4) (B.00A01.X2/22.5)
.Local.20-FC2 24 12 22 14 24 24
I>> I>> I>>

(B.25A1.V2/70.2)

(.5)

.MCC01-P1:1d

.MCC01-M:2d
SIEMENS
3VA2440-5MN32-0AA0 2 4 6
100-400 A
270 A

-TA1:XD2D:1 (B.20A1-M1/40.2)
PE -TA1:XD2D:2
B (B.20A1-M1/40.2) B

Eth
Ethernet Cable -TA1:XD2D:3
.MCC01-W60 (B.20A1-M1/40.2)

Profinet Interface
-TA2 L1 L2 L3 PE 1 2 1 2 3 4 5 6 7 1 2 3 4 1 2 3 1 2 3 4 X205 X13 X12

SUPPLY

AO1

AO2

OUT1

IN1

IN2
+24VI

GND

AGND

AI1+

DI3+

AGND

AGND

BGND

SGND

Memory unit

Safety functions mod.


+VREF

-VREF

AI1-

AI2-

Control panel

FENA-21
XPOW XAI XAO XD2D XSTO

ABB
13
ACS880-01-430A-3+E200+K475+P904+Q973
.Local.20-FC2

Address:
(B.00A01.X1B4I.MCC01/33.5)
? ? XD24 XDI XDIO
R+/UDC+

XRO1 XRO2 XRO3

DIOGND
(B.Local.20.2)

DICOM

+24VD
UDC-

DIO1

DIO2
GND
C C

DIIL
14

DI1

DI2

DI3

DI4

DI5

DI6
PE

MOTOR

U V W PE 11 12 13 21 22 23 31 32 33 1 2 3 4 5 1 2 3 4 5 6 1 2 ETHETH

Eth
.MCC01-W58
-A06:P7 (B4I.MCC01/29.4)
Ethernet Cable
expressly agreed to by ANDRITZ AG or one of its affiliates.

Sh
.MCC01-X11
3
4
GNYE
GY
BN
BK

1
2

B.20A1-M2-W01 B.20A1-M2-W111
D NYCWY Oelflex Classic 110 BK CY
D
3 x 120 SM / 70 2x1

+B.Local.20
U1 V1 W1 PE
Schredder

M
3~ 1
ϑ ϑ ϑ
2

B.20A1-M2

Main Drive LH

160 kW
271 A
E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Shredder Project: RECYCLING-PRODUCTS Function Unit: B.20A1-M2
Created: Prettner MCC Project no.: M Location: +B.Local.20
Checked: Pereira-Perez / 05.03.2020 Cabinet diagram Power Customer: RECYCLING-STANDARD Page: 41 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:44:31
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|20|A1|Z4|G1|PFSS.42 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC01
MCC Cabinet
Slip Monitoring RH = 1
-P2:1d
(B4I.MCC01/19.4)
ET200SP 8-DI ST
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

-X21-JB05:1 Ref.: (27.2)


A (B4I.MCC01/20.7)
Label: -A01-36
A
(B4I.MCC01/20.7) -X21-JB05:2
-X21-JB05:PE Loc.:
(B4I.MCC01/20.7)
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

Sort: DI
I306.2
DI20A1G1_GI

3
DI2
-X61-JB05

1
2
GNYE
B B

1
2

1
2
+B4I.JB05-W11 +B4I.JB05-W12

Oelflex Classic 110 BK Oelflex Classic 110 BK


3G2,5 5G1
-X61:5 (B.20A1.G2/43.4)

+B4I.JB05 -X21

1
-X21:4 (B.20A1.G2/43.4)
JB Slip Montoring

2
-X21:5 (B.20A1.G2/43.4)

3
-X21:6 (B.20A1.G2/43.4)
-X61

1
2
3
1 2 PE 3 4 5 -GT
L N PE NC C NO ESC130 RINGSPANN
DIP1 DIP2 DIP3 Relais ESC130
On Input 1
C Off
1 2 3 4 1 2 3 4 5 6 7 1 2 3 4 5 6 7 B1 Input 2 C
Input Speed Function
Status

Input 1 10 VDC Input 2 10 VDC

NPN

NPN
PNP

PNP
- + - +
6 7 8 9 10 11 12 13
expressly agreed to by ANDRITZ AG or one of its affiliates.

PE
3
1
2

6
4
5
GNYE

GNYE
1
2
3

1
2
3
B.20A1.G1-W71 B.20A1.G1-W72
D Original Cable Original Cable
D
4x0,75 4x0,75

+B.Local.20
Schredder
GND

GND
1
4
3

1
4
3
0-10V 0-10V

-GE1 -GE2
CONTRINEX CONTRINEX
DW-AS-509-M12 DW-AS-509-M12

G G

E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Shredder Project: RECYCLING-PRODUCTS Function Unit: B.20A1.G1
Created: Prettner Position Monitoring RH Project no.: GS Location: +B4I.JB05
Checked: Pereira-Perez / 05.03.2020 Circuit diagram Customer: RECYCLING-STANDARD Page: 42 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:44:33
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|20|A1|Z4|G2|PFSS.43 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC01
MCC Cabinet
Slip Monitoring LH = 1

ET200SP 8-DI ST
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

Ref.: (27.2)
A Label: -A01-36
A
Loc.:
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

Sort: DI
I306.3
DI20A1G2_GI

4
DI3
-X61-JB05

3
B B

3
+B4I.JB05-W12

Oelflex Classic 110 BK


5G1

+B4I.JB05 -X21

4
(B.20A1.G1/42.4) -X21:1 -X61:2 (B.20A1.G1/42.4)
JB Slip Montoring -X61

4
5
6
(B.20A1.G1/42.4) -X21:2

6
(B.20A1.G1/42.4) -X21:3

1 2 PE 3 4 5 -GT
L N PE NC C NO ESC130 RINGSPANN
DIP1 DIP2 DIP3 Relais ESC130
On Input 1
C Off
1 2 3 4 1 2 3 4 5 6 7 1 2 3 4 5 6 7 B1 Input 2 C
Input Speed Function
Status

Input 1 10 VDC Input 2 10 VDC

NPN

NPN
PNP

PNP
- + - +
6 7 8 9 10 11 12 13
expressly agreed to by ANDRITZ AG or one of its affiliates.

PE
12
10
11
-X62
9
7
8

GNYE

GNYE
1
2
3

1
2
3
B.20A1.G2-W71 B.20A1.G2-W72
D Original Cable Original Cable
D
4x0,75 4x0,75

+B.Local.20
Schredder
GND

GND
1
4
3

1
4
3
0-10V 0-10V

-GE1 -GE2
CONTRINEX CONTRINEX
DW-AS-509-M12 DW-AS-509-M12

G G

E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Shredder Project: RECYCLING-PRODUCTS Function Unit: B.20A1.G2
Created: Prettner Position Monitoring LH Project no.: GS Location: +B4I.JB05
Checked: Pereira-Perez / 05.03.2020 Circuit diagram Customer: RECYCLING-STANDARD Page: 43 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:44:34
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|20|A1|Z4|H2|PFSS.44 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC01
MCC Cabinet
Local Start REV = 1 Local Start FWD = 1

ET200SP 8-DI ST ET200SP 8-DI ST


This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

Ref.: (26.5) Ref.: (26.5)


A Label: -A01-32 Label: -A01-32
A
Loc.: Loc.:
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

Sort: DI Sort: DI
I302.6 I302.5
DI20A1H2_S12 DI20A1H2_S11

6
DI6

DI5
13

14
-X61-CP01

B B

13

14
+B4I.CB01-W12

Oelflex Classic 110 BK


34G1

+B4I.CB01

13

14
Local Control Panel 1 -X61

(B.00A02.H6/37.4) -S1:23 -S1:13 (B.20A2.H1/54.3)


C C

13 23
102
-S1
expressly agreed to by ANDRITZ AG or one of its affiliates.

RH / LH REV / FWD 14 24

D D

E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Shredder Project: RECYCLING-PRODUCTS Function Unit: B.20A1.H2
Created: Prettner Local Operation Project no.: HS Location: +B4I.CB01
Checked: Pereira-Perez / 05.03.2020 Circuit diagram Customer: RECYCLING-STANDARD Page: 44 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:44:36
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|20|A1|Z4|H3|PFSS.45 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC01
MCC Cabinet
Local Start FWD = 1 Local Start REV = 1 Local Start = 1

ET200SP, F, 8-DI HF ET200SP, F, 8-DI HF ET200SP, F, 8-DI HF


This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

Ref.: (26.3) Ref.: (26.3) Ref.: (26.3)


A Label: -A01-11 Label: -A01-11 Label: -A01-11
A
Loc.: Loc.: Loc.:
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

Sort: SRS-DI Sort: SRS-DI Sort: SRS-DI


I6.0 I6.4 I6.5
DI20A1H3_S13 DI20A1H3_S14 DI20A1H2_S15

6
DI0

DI4

DI5
-X61-CP02

8
B B

8
-W61

Oelflex Classic 110 BK


12G1

+B4I.CB02
Local Control Panel 2 -X61

8
(B.20A5.H1/65.4) -S1:23 -S1:13 (B.20A2.H2/55.3)
C C

-S1 13 23 33 43
102
RH / LH REV / FWD
expressly agreed to by ANDRITZ AG or one of its affiliates.

14 24 34 44

D D

E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Shredder Project: RECYCLING-PRODUCTS Function Unit: B.20A1.H3
Created: Prettner Local Operation 2 Project no.: HS Location: +B4I.CB02
Checked: Pereira-Perez / 05.03.2020 Circuit diagram Customer: RECYCLING-STANDARD Page: 45 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:44:37
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|20|A1|Z4|S1|PFSS.46 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC01
MCC Cabinet
Pulse of Incremental SPEED PULSE 1 SPEED PULSE 2

ET200SP, 1 Count 24VDC SM1281 SM1281


This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

Ref.: (27.6) Ref.: (28.3) Ref.: (28.5)


A Label: -A01-80 Label: -A02-03 Label: -A02-04
A
Loc.: Loc.: Loc.:
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

Sort: DI Sort: AI Sort: AI


I318.0 RPM RPM
DI20A1S1_SE DI20A1S1_SE DI20A1S1_SE

0
IN

IN
P

P
-P1:3c

24VDC
(19.3)

X10
X10
X10

X10
X10
X10
-M:3a
(19.2)

PE
-X81-JB01

1
2
3
8
B B

1
2
3
4
+B4I.JB01-W81

Oelflex Classic 110 BK CY


4x0,75

+B4I.JB01
Junction Box

PE
-X81

1
2
3
8
wh
bn

gn
bu
C B.20A1.S1-W81 C
Original Cable
8 x 0,25

+B.Local.20
Schredder
expressly agreed to by ANDRITZ AG or one of its affiliates.

D GND D
2
1
3
4
5
6
7
8

Connections
+24V BN/2
PH
+V

-SE
0V

A-

B-

0-
A

Kübler 0V WH/1
8.5020.2552.1000
A GN/3
1000 imp/rpm
A YE/4
B GY/5
B PK/6
0 BU/7
0 RD/8

E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Shredder Project: RECYCLING-PRODUCTS Function Unit: B.20A1.S1
Created: Prettner Speed Indication Project no.: SI Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 Circuit diagram Customer: RECYCLING-STANDARD Page: 46 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:44:38
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|20|A1|Z4|T1|PFSS.47 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC01
MCC Cabinet
Actual Temperature

ET200SP, I 2/4 WIRE, 2AI ST


This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

Ref.: (27.5)
A Label: -A01-60
A
Loc.:
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

Sort: AI
IW1500
AI20A1T1_TT

5
7
9
13
15
I0-
I0+

1UV0
2UV0
2M0
PE
-X81-JB01

5
B B

WH
BR
B.20A1.T1-W81

Oelflex Classic 110 BK CY


2x1

+B4I.JB01
Junction Box

PE
-X81

5
1

2
C B.20A1.T1-W82 C
Oelflex Classic 110 BK CY
2x1

+B.Local.20
Schredder
expressly agreed to by ANDRITZ AG or one of its affiliates.

PE

D D
GND
s+

s-

4-20mA

-TT
ROSSI
RSM00087/B

-40..200 °C
E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Shredder Project: RECYCLING-PRODUCTS Function Unit: B.20A1.T1
Created: Prettner Gearbox temperature control RH Project no.: TI Location:
Checked: Pereira-Perez / 05.03.2020 Circuit diagram Customer: RECYCLING-STANDARD Page: 47 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:44:40
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|20|A1|Z4|T2|PFSS.48 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC01
MCC Cabinet
Actual Temperature

ET200SP, I 2/4 WIRE, 2AI ST


This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

Ref.: (27.5)
A Label: -A01-60
A
Loc.:
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

Sort: AI
IW1502
AI20A1T2_TT

6
8
10
14
16
I1-
I1+

1UV1
2UV1
2M1
PE
-X81-JB01

7
B B

WH
BR
B.20A1.T2-W81

Oelflex Classic 110 BK CY


2x1

+B4I.JB01
Junction Box

PE
-X81

7
1

2
C B.20A1.T2-W82 C
Oelflex Classic 110 BK CY
2x1

+B.Local.20
Schredder
expressly agreed to by ANDRITZ AG or one of its affiliates.

PE

D D
GND
s+

s-

4-20mA

-TT
ROSSI
RSM00087/B

-40..200 °C
E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Shredder Project: RECYCLING-PRODUCTS Function Unit: B.20A1.T2
Created: Prettner Gearbox temperature control LH Project no.: TI Location:
Checked: Pereira-Perez / 05.03.2020 Circuit diagram Customer: RECYCLING-STANDARD Page: 48 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:44:41
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|20|A1|Z4|V1|PFSS.49 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC01
MCC Cabinet
Vibration X Vibration Y Vibration Z

SM1281 SM1281 SM1281


This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

Ref.: (28.3) Ref.: (28.3) Ref.: (28.3)


A Label: -A02-03 Label: -A02-03 Label: -A02-03
A
Loc.: Loc.: Loc.:
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

Sort: AI Sort: AI Sort: AI


VIB1 VIB2 VIB3

1-

2-

3-
1+

2+

3+
X11

X11

X11

X11

X11

X11
-X81-JB10

PE
2

6
B B

4
+B4I.JB10-W81

Oelflex Classic 110 BK CY


4x1

+B4I.JB10
JB Condition Monitoring

PE
-X81

4
BN WH BU BK
C -W81 C
Original Cable
HS-AC010-20

+B.Local.20
Schredder
expressly agreed to by ANDRITZ AG or one of its affiliates.

D D

GND
1
2
3
4

-XE
X
Y

0V
Z

HANSFORD SENSORS
HS1731005408

E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Shredder Project: RECYCLING-PRODUCTS Function Unit: B.20A1.V1
Created: Prettner Condition Monitoring Project no.: XS Location:
Checked: Pereira-Perez / 05.03.2020 Circuit diagram Customer: RECYCLING-STANDARD Page: 49 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:44:42
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|20|A1|Z4|V2|PFSS.50 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC01
MCC Cabinet
Vibration

SM1281
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

Ref.: (28.5)
A Label: -A02-04
A
Loc.:
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

Sort: AI
VIB1

1-
1+
X11

X11

PE
-X82-JB10

2
B B

1WH
1OR
+B4I.JB10-W82

Li2YCY PiMF
4x2x1,0

+B4I.JB10
JB Condition Monitoring

PE
-X82

2
WH BK
C -W81 C
Original Cable
HS-AC010-20

+B.Local.20
Schredder
expressly agreed to by ANDRITZ AG or one of its affiliates.

D D

GND
A

-XE
HANSFORD SENSORS
HS100S1005408

E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Shredder Project: RECYCLING-PRODUCTS Function Unit: B.20A1.V2
Created: Prettner Vibration DE Project no.: XS Location:
Checked: Pereira-Perez / 05.03.2020 Circuit diagram Customer: RECYCLING-STANDARD Page: 50 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:44:44
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|20|A1|Z4|V3|PFSS.51 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC01
MCC Cabinet
Vibration

SM1281
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

Ref.: (28.5)
A Label: -A02-04
A
Loc.:
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

Sort: AI
VIB2

2-
2+
X11

X11

PE
-X82-JB10

5
B B

2WH
2OR
+B4I.JB10-W82

Li2YCY PiMF
4x2x1,0

+B4I.JB10
JB Condition Monitoring

PE
-X82

5
WH BK
C -W81 C
Original Cable
HS-AC010-20

+B.Local.20
Schredder
expressly agreed to by ANDRITZ AG or one of its affiliates.

D D

GND
A

-XE
HANSFORD SENSORS
HS100S1005408

E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Shredder Project: RECYCLING-PRODUCTS Function Unit: B.20A1.V3
Created: Prettner Vibration NDE Project no.: XS Location:
Checked: Pereira-Perez / 05.03.2020 Circuit diagram Customer: RECYCLING-STANDARD Page: 51 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:44:45
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|20|A2|Z4|G1|PFSS.52 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC01
MCC Cabinet
Pusher in Rear Position = 1

ET200SP 8-DI ST
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

Ref.: (26.5)
A Label: -A01-32
A
Loc.:
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

Sort: DI
I302.0
DI20A2G1_GS

1
-P1:4d

DI0
(19.3)
-M:4c
(19.2)

-X61-JB01

1
2
3
B B

1
2
3
+B4I.JB01-W61

Oelflex Classic 110 BK


34G1

+B4I.JB01
Junction Box
-X61

1
-X61:4 (B.20A2.G2/53.4)

2
-X61:5 (B.20A2.G2/53.4)

3
1
2
3
C B.20A2.G1-W61 C
Oelflex Classic 110 BK
4G1

+B.Local.20
Schredder
expressly agreed to by ANDRITZ AG or one of its affiliates.

D D
1
2
3
NO 4
NC

-GS
+

TELEMECANIQUE
-

XS8C4A1PCP20

G
0..16 mm

E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Pusher Project: RECYCLING-PRODUCTS Function Unit: B.20A2.G1
Created: Prettner Pusher in Rear Position Project no.: GS Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 Circuit diagram Customer: RECYCLING-STANDARD Page: 52 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:44:46
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|20|A2|Z4|G2|PFSS.53 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC01
MCC Cabinet
Pusher in Front Position = 1

ET200SP 8-DI ST
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

Ref.: (26.5)
A Label: -A01-32
A
Loc.:
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

Sort: DI
I302.1
DI20A2G2_GS

2
DI1
-X61-JB01

4
B B

4
+B4I.JB01-W61

Oelflex Classic 110 BK


34G1

+B4I.JB01
Junction Box
-X61

4
(B.20A2.G1/52.4) -X61:1 -X61:7 (B.20A3.G1/56.4)

5
(B.20A2.G1/52.4) -X61:2 -X61:8 (B.20A3.G1/56.4)

6
1
2
3
C B.20A2.G2-W61 C
Oelflex Classic 110 BK
4G1

+B.Local.20
Schredder
expressly agreed to by ANDRITZ AG or one of its affiliates.

D D
1
2
3
NO 4
NC

-GS
+

TELEMECANIQUE
-

XS8C4A1PCP20

G
0..16 mm

E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Pusher Project: RECYCLING-PRODUCTS Function Unit: B.20A2.G2
Created: Prettner Pusher in Front Position Project no.: GS Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 Circuit diagram Customer: RECYCLING-STANDARD Page: 53 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:44:48
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|20|A2|Z4|H1|PFSS.54 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC01
MCC Cabinet
Local Command REV = 1 Local Command FWD = 1

ET200SP 8-DI ST ET200SP 8-DI ST


This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

Ref.: (26.6) Ref.: (26.6)


A Label: -A01-33 Label: -A01-33
A
Loc.: Loc.:
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

Sort: DI Sort: DI
I303.2 I303.1
DI20A2H1_S12 DI20A2H1_S11

2
DI2

DI1
15

16
-X61-CP01

B B

15

16
+B4I.CB01-W12

Oelflex Classic 110 BK


34G1

+B4I.CB01

15

16
Local Control Panel 1 -X61

(B.20A1.H2/44.4) -S1:13 -S1:13 (B.20A3.H1/59.3)


C C

13 23
102
-S1
expressly agreed to by ANDRITZ AG or one of its affiliates.

LH RH REV FWD 14 24

D D

REV FWD

E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Pusher Project: RECYCLING-PRODUCTS Function Unit: B.20A2.H1
Created: Prettner Local Operation Project no.: HS Location: +B4I.CB01
Checked: Pereira-Perez / 05.03.2020 Circuit diagram Customer: RECYCLING-STANDARD Page: 54 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:44:49
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|20|A2|Z4|H2|PFSS.55 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC01
MCC Cabinet
Local Command REV = 1 Local Command FWD = 1

ET200SP 8-DI ST ET200SP 8-DI ST


This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

Ref.: (27.2) Ref.: (27.2)


A Label: -A01-36 Label: -A01-36
A
Loc.: Loc.:
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

Sort: DI Sort: DI
I306.4 I306.5
DI20A2H2_S12 DI20A2H2_S11

6
DI4

DI5
10
-X61-CP02

9
B B

10
9
-W61

Oelflex Classic 110 BK


12G1

+B4I.CB02

10
Local Control Panel 2 -X61

(B.20A1.H3/45.5) -S1:43
C C

13 23
102
-S1
expressly agreed to by ANDRITZ AG or one of its affiliates.

LH RH REV FWD 14 24

D D

E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Pusher Project: RECYCLING-PRODUCTS Function Unit: B.20A2.H2
Created: Prettner Local Operation Project no.: HS Location: +B4I.CB02
Checked: Pereira-Perez / 05.03.2020 Circuit diagram Customer: RECYCLING-STANDARD Page: 55 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:44:50
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|20|A3|Z4|G1|PFSS.56 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC01
MCC Cabinet
Service Hatch Closed = 1 Service Hatch Closed = 1

ET200SP, F, 8-DI HF ET200SP, F, 8-DI HF


This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

Ref.: (26.2) Ref.: (26.2)


A Label: -A01-10 Label: -A01-10
A
Loc.: Loc.:
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

Sort: SRS-DI Sort: SRS-DI


I0.1 I0.5
DI20A3G1_GSZ DI20A3G1_GSZ.1

10

14
DI1

VS1

DI5

VS5
-X61-JB01

5
6
7
8
B B

5
6
7
8
+B4I.JB01-W61

Oelflex Classic 110 BK


34G1

+B4I.JB01
Junction Box -X61

7
(B.20A2.G2/53.4) -X61:4

8
(B.20A2.G2/53.4) -X61:5

10
11
12
9
wh
bn

gn
ye
pk
bl
C -W1 C
Original Cable
8 x 0,34

+B.Local.20
Schredder
expressly agreed to by ANDRITZ AG or one of its affiliates.

D D
S11
S21

Y32
A1
A2

12
22

-GSZ
PILZ
PSEN CS1.1P

G
0..21 mm

E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Service Hatch Project: RECYCLING-PRODUCTS Function Unit: B.20A3.G1
Created: Prettner Service Hatch Closed Project no.: GSZ Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 Circuit diagram Customer: RECYCLING-STANDARD Page: 56 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:44:51
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|20|A3|Z4|G2|PFSS.57 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC01
MCC Cabinet
Service Hatch Unlocked = 1

ET200SP 8-DI ST
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

Ref.: (26.5)
A Label: -A01-32
A
Loc.:
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

Sort: DI
I302.4
DI20A3G2_GS

5
-P1:5d

DI4
(19.3)
-M:6d
(19.2)

10
11
-X61-JB01

9
B B

10
11
9
+B4I.JB01-W61

Oelflex Classic 110 BK


34G1

+B4I.JB01
Junction Box

13
-X61 -X61:16 (B.20A3.G3/58.4)

14
-X61:17 (B.20A3.G3/58.4)

15
1
2
3
C B.20A3.G2-W61 C
Oelflex Classic 110 BK
4G1

+B.Local.20
Schredder
expressly agreed to by ANDRITZ AG or one of its affiliates.

D D
1
2
3
NO 4
NC

-GS
+

TELEMECANIQUE
-

XS8C4A1PCP20

G
0..16 mm

E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Service Hatch Project: RECYCLING-PRODUCTS Function Unit: B.20A3.G2
Created: Prettner Service Hatch Unlocked Project no.: GS Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 Circuit diagram Customer: RECYCLING-STANDARD Page: 57 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:44:53
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|20|A3|Z4|G3|PFSS.58 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC01
MCC Cabinet
Service Hatch Locked = 1

ET200SP 8-DI ST
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

Ref.: (26.6)
A Label: -A01-33
A
Loc.:
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

Sort: DI
I303.3
DI20A3G3_GS

4
DI3
12
-X61-JB01

B B

12
+B4I.JB01-W61

Oelflex Classic 110 BK


34G1

+B4I.JB01
Junction Box

16
-X61:13 -X61 -X61:19
(B.20A3.G2/57.4) (B.20A4.G1/60.4)

17
(B.20A3.G2/57.4) -X61:14 -X61:20 (B.20A4.G1/60.4)

18
1
2
3
C B.20A3.G3-W61 C
Oelflex Classic 110 BK
4G1

+B.Local.20
Schredder
expressly agreed to by ANDRITZ AG or one of its affiliates.

D D
1
2
3
NO 4
NC

-GS
+

TELEMECANIQUE
-

XS8C4A1PCP20

G
0..16 mm

E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Service Hatch Project: RECYCLING-PRODUCTS Function Unit: B.20A3.G3
Created: Prettner Service Hatch Locked Project no.: GS Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 Circuit diagram Customer: RECYCLING-STANDARD Page: 58 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:44:54
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|20|A3|Z4|H1|PFSS.59 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC01
Local Command Open Local Command Close
MCC Cabinet
=1 =1

ET200SP 8-DI ST ET200SP 8-DI ST


This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

Ref.: (26.6) Ref.: (26.6)


A Label: -A01-34 Label: -A01-34
A
Loc.: Loc.:
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

Sort: DI Sort: DI
I304.2 I304.3
DI20A3H1_S11 DI20A3H1_S12

4
DI2

DI3
17

18
-X61-CP01

B B

17

18
+B4I.CB01-W12

Oelflex Classic 110 BK


34G1

+B4I.CB01

17

18
Local Control Panel 1 -X61

(B.20A2.H1/54.4) -S1:23
C C

13 23
102
-S1
expressly agreed to by ANDRITZ AG or one of its affiliates.

SLH/RH STOP/START 14 24

D D

E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Service Hatch Project: RECYCLING-PRODUCTS Function Unit: B.20A3.H1
Created: Prettner Local Operation Project no.: HS Location: +B4I.CB01
Checked: Pereira-Perez / 05.03.2020 Circuit diagram Customer: RECYCLING-STANDARD Page: 59 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:44:55
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|20|A4|Z4|G1|PFSS.60 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC01
MCC Cabinet
Reject Hatch Closed = 1 Reject Hatch Closed = 1

ET200SP, F, 8-DI HF ET200SP, F, 8-DI HF


This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

Ref.: (26.2) Ref.: (26.2)


A Label: -A01-10 Label: -A01-10
A
Loc.: Loc.:
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

Sort: SRS-DI Sort: SRS-DI


I0.3 I0.7
DI20A4G1_GSZ DI20A4G1_GSZ

12

16
DI3

VS3

DI7

VS7
10
11
-X62-JB01

6
9
B B

10
11
6
9
+B4I.JB01-W62

Oelflex Classic 110 BK


12G1

+B4I.JB01

19
Junction Box -X61:16 -X61 -X61:22
(B.20A3.G3/58.4) (B.20A4.G2/61.3)

20
(B.20A3.G3/58.4) -X61:17 -X61:23 (B.20A4.G2/61.3)

21
54
55
56
wh
bn

gn
ye
pk
bl
C -W1 C
Original Cable
8 x 0,34

+B.Local.20
Schredder
expressly agreed to by ANDRITZ AG or one of its affiliates.

D D
S11
S21

Y32
A1
A2

12
22

-GSZ
PILZ
PSEN CS1.1P

G
0..21 mm

E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Reject Hatch Project: RECYCLING-PRODUCTS Function Unit: B.20A4.G1
Created: Prettner Reject Hatch Closed Project no.: GSZ Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 Circuit diagram Customer: RECYCLING-STANDARD Page: 60 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:44:56
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|20|A4|Z4|G2|PFSS.61 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC01
Reject Hatch Unlocked
MCC Cabinet
1=1 Reject Hatch Unlocked 2 = 1

ET200SP 8-DI ST ET200SP 8-DI ST


This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

Ref.: (26.6) Ref.: (27.2)


A Label: -A01-34 Label: -A01-36
A
Loc.: Loc.:
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

Sort: DI Sort: DI
I304.1 I306.1
DI20A4G2_GS1 DI20A4G3_GS2

2
DI1

DI1
14

15
-X61-JB01 -X61-JB01

B B

14

15
+B4I.JB01-W61

Oelflex Classic 110 BK


34G1

+B4I.JB01
Junction Box

22

25
-X61:19 -X61 -X61 -X61:31
(B.20A4.G1/60.4) (B.20A4.G3/62.5)

23

26
(B.20A4.G1/60.4) -X61:20 -X61:32 (B.20A4.G3/62.5)

24

27
1
2
3

1
2
3
C B.20A4.G2-W61 B.20A4.G2-W62 C
Oelflex Classic 110 BK Oelflex Classic 110 BK
4G1 4G1

+B.Local.20
Schredder
expressly agreed to by ANDRITZ AG or one of its affiliates.

D D
1
2
3
4

1
2
3
4
NO

NO
NC

NC
-GS1 -GS2
+

+
TELEMECANIQUE TELEMECANIQUE
-

-
XS8C4A1PCP20 XS8C4A1PCP20

G G
0..16 mm 0..16 mm

E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Reject Hatch Project: RECYCLING-PRODUCTS Function Unit: B.20A4.G2
Created: Prettner Reject Hatch Unlocked Project no.: GS Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 Circuit diagram Customer: RECYCLING-STANDARD Page: 61 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:44:58
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|20|A4|Z4|G3|PFSS.62 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC01
Reject Hatch Locked

(19.2)
MCC Cabinet
1=1 Reject Hatch Locked 2 = 1 Reject hatch locked

-M:10b
ET200SP 8-DI ST ET200SP 8-DI ST ET200SP 8-DO
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

Ref.: (26.6) Ref.: (27.2) Ref.: (27.2)


A Label: -A01-33 Label: -A01-36 Label: -A01-40
A
Loc.: Loc.: Loc.:
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

Sort: DI Sort: DI Sort: DO


I303.7 I306.0 Q300.7
DI20A4G3_GS1 DI20A4G2_GS2 DO20A4G3_LCK

8
DI7

DI0

DO7
17

2
16
-X71-CP02

1
-X61-JB01

B B

16

17

2
+B4I.JB01-W61 +B4I.CB02-W62

Oelflex Classic 110 BK Oelflex Classic 110 BK


34G1 4G1

+B4I.JB01 +B4I.CB02
Junction Box Local Control Panel 2 -X71

2
28

31
-X61:22 -X61 -X61
(B.20A4.G2/61.3) 1

29

32
-X61:23 Green
(B.20A4.G2/61.3)

30

33
-H1

1
2
3

1
2
3
C B.20A4.G3-W61 B.20A4.G3-W62 C
Oelflex Classic 110 BK Oelflex Classic 110 BK
4G1 4G1

+B.Local.20
Schredder
expressly agreed to by ANDRITZ AG or one of its affiliates.

D D
1
2
3
4

1
2
3
4
NO
NC

-GS1

NO
NC
-GS2
+

TELEMECANIQUE
-

-
XS8C4A1PCP20 TELEMECANIQUE
XS8C4A1PCP20

G
0..16 mm
G
0..16 mm
E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Reject Hatch Project: RECYCLING-PRODUCTS Function Unit: B.20A4.G3
Created: Prettner Reject Hatch Locked Project no.: GS Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 Circuit diagram Customer: RECYCLING-STANDARD Page: 62 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:44:59
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|20|A4|Z4|H1|PFSS.63 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC01
MCC Cabinet
Local Command Close = 1 Local Command Open = 1

ET200SP 8-DI ST ET200SP 8-DI ST


This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

Ref.: (26.6) Ref.: (26.6)


A Label: -A01-34 Label: -A01-34
A
Loc.: Loc.:
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

Sort: DI Sort: DI
I304.5 I304.4
DI20A4H1_S12 DI20A4H1_S11

5
-P1:6d

DI5

DI4
(B4I.MCC01/19.3)

-X61-CP02

3
B B

3
-W61

Oelflex Classic 110 BK


12G1

+B4I.CB02
Local Control Panel 2 -X61

3
-S1:13 (B.20A5.H1/65.3)
C C

-S1 13 23
102
LH / RH CLOSE / OPEN
expressly agreed to by ANDRITZ AG or one of its affiliates.

14 24

D D

E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Reject Hatch Project: RECYCLING-PRODUCTS Function Unit: B.20A4.H1
Created: Prettner Local Operation Project no.: HS Location: +B4I.CB02
Checked: Pereira-Perez / 05.03.2020 Circuit diagram Customer: RECYCLING-STANDARD Page: 63 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:45:01
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|20|A5|Z4|G1|PFSS.64 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC01
MCC Cabinet
Screen Basket Closed = 1 Screen Basket Closed = 1

ET200SP, F, 8-DI HF ET200SP, F, 8-DI HF


This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

Ref.: (26.2) Ref.: (26.2)


A Label: -A01-10 Label: -A01-10
A
Loc.: Loc.:
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

Sort: SRS-DI Sort: SRS-DI


I0.2 I0.6
DI20A5G1_GSZ DI20A5G1_GSZ.1

11

15
DI2

VS2

DI6

VS6
18
19
20
21
-X61-JB01

B B

18
19
20
21
+B4I.JB01-W61

Oelflex Classic 110 BK


34G1

+B4I.JB01

34
Junction Box -X61:28 -X61
(B.20A4.G3/62.3)

35
(B.20A4.G3/62.3) -X61:29

36
37
38
39
wh
bn

gn
ye
pk
bl
C -W1 C
Original Cable
8 x 0,34

+B.Local.20
Schredder
expressly agreed to by ANDRITZ AG or one of its affiliates.

D D
S11
S21

Y32
A1
A2

12
22

-GSZ
PILZ
PSEN CS1.1P

G
0..21 mm

E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Screen Basket Project: RECYCLING-PRODUCTS Function Unit: B.20A5.G1
Created: Prettner Screen Basket Closed Project no.: GSZ Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 Circuit diagram Customer: RECYCLING-STANDARD Page: 64 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:45:02
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|20|A5|Z4|H1|PFSS.65 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC01
MCC Cabinet
Local Command Open = 1 Local Command Close = 1

ET200SP 8-DI ST ET200SP 8-DI ST


This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

Ref.: (26.6) Ref.:


A Label: -A01-34 Label: -A01-34
A
Loc.: Loc.:
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

Sort: DI Sort: DI
I304.6 I304.7
DI20A5H1_S11 DI20A5H1_S12

8
DI6

DI7
-X61-CP02

5
B B

5
-W61

Oelflex Classic 110 BK


12G1

+B4I.CB02
Local Control Panel 2 -X61

5
(B.20A4.H1/63.4) -S1:23 -S1:13 (B.20A1.H3/45.4)
C C

-S1 13 23
102
expressly agreed to by ANDRITZ AG or one of its affiliates.

14 24

D D

E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Screen Basket Project: RECYCLING-PRODUCTS Function Unit: B.20A5.H1
Created: Prettner Local Operation Project no.: HS Location: +B4I.CB02
Checked: Pereira-Perez / 05.03.2020 Circuit diagram Customer: RECYCLING-STANDARD Page: 65 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:45:03
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|20|A6|Z4|X1|PFSS.66 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC01
MCC Cabinet
Command Start = 1 Lubrication Pulse = 1

ET200SP 8-DO ET200SP 8-DI ST


This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

Ref.: (27.3) Ref.: (26.5)


A Label: -A01-41 Label: -A01-32
A
Loc.: Loc.:
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

Sort: DO Sort: DI
-P1:6c Q301.2 I302.3
(19.3)
-M:4b DO20A6X1_CO DI20A6X1_PLS
(19.2)

4
1 3 5

DO2

DI3
-QA1
-P1:7a
(.4) A1 (19.3)
-A01-32:3
2 4 6 -QA1 (B.20A6.L1/74.4)
SIEMENS

22
23

24
25
26
-X61-JB01 3RT2015-1BB41
3 kW A2

B B

22
23

24
25
26
+B4I.JB01-W61

Oelflex Classic 110 BK


34G1

+B4I.JB01
1 2
Junction Box (.3)
3 4

5 6
PE
40
41

42
43
44
-X61 13 14
?
GNYE
RD

RD
BN

BN
BK
C B.20A6.X1-W41 B.20A6.X1-W61 C
Original Cable Original Cable
3G1 4G2.5

+B.Local.20
Schredder
expressly agreed to by ANDRITZ AG or one of its affiliates.

D D
X1:PE

X2:PE
X1:1
X1:2
X1:3

X2:1
X2:2
X2:3
0V
24VDC

-XC
LINCOLN
P
L

P401-SSV 6-V- 24DC-2XL-2A1.5

E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Greasing Unit Project: RECYCLING-PRODUCTS Function Unit: B.20A6.X1
Created: Prettner Lubrication Control Project no.: XS Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 Circuit diagram Customer: RECYCLING-STANDARD Page: 66 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:45:05
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|25|A1|Z4|L1|PFSS.67 Final date of print: 30.03.2020

1 2 3 4 5 6 7
Temperature > HH
+B4I.MCC01
Level < L = 0 Level < LL = 0 Temperature > H = 0 =0

(B4I.MCC01/19.6)
(B4I.MCC01/19.2)
MCC Cabinet
ET200SP 8-DI ST ET200SP 8-DI ST ET200SP 8-DI ST ET200SP 8-DI ST
Ref.: (27.1) Ref.: (27.1) Ref.: (27.1) Ref.: (27.1)
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

Label: -A01-35 Label: -A01-35 Label: -A01-35 Label: -A01-35


A Loc.: Loc.: Loc.: Loc.:
A
Sort: DI Sort: DI Sort: DI Sort: DI
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

I305.0 I305.1 I305.2 I305.3


DI25A1L1_LSL DI25A1L1_LSLL DI25A1T1_TSH DI25A1T1_TSHH

-P4:1b
-M:7a

4
DI0

DI1

DI2

DI3
-X61-JB02

1
2

6
B B

1
2
3
4

5
6
+B4I.JB02-W61

Oelflex Classic 110 BK


18G1

+B4I.JB02
Junction Box
-X61

5
-X61:9 (B.25A1.P1/68.4)

6
-X61:10 (B.25A1.P1/68.4)

3
4

7
8
PE

PE
WH

WH
BN
BU

BN
BU
BK

BK
C B.25A1.L1-W61 B.25A1.L1-W62 C
Original Cable Original Cable
4x0,34 4x0,34

+B.Local.25
Hydraulic
expressly agreed to by ANDRITZ AG or one of its affiliates.

D D
A:1
A:3
A:2
A:4
B:1
B:3
B:2
B:4
contact

-LS
GND
+UB

+UB

T1

T2
L1

L2

BUEHLER
L/LL H/HH NT64D-MS-2M12/370-2K-170NO-250NO-2T
T1=70/45 ; T2=75/65

POS 1.40
E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Hydraulic Panel Project: RECYCLING-PRODUCTS Function Unit: B.25A1.L1
Created: Prettner Hydraulic Level Low Project no.: LS Location:
Checked: Pereira-Perez / 05.03.2020 Circuit diagram Customer: RECYCLING-STANDARD Page: 67 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:45:06
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|25|A1|Z4|P1|PFSS.68 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC01
MCC Cabinet
Press. > High = 0

ET200SP 8-DI ST
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

Ref.: (26.6)
A Label: -A01-33
A
Loc.:
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

Sort: DI
I303.4
DI25A1P1_PDS

5
DI4
-X61-JB02

7
B B

7
+B4I.JB02-W61

Oelflex Classic 110 BK


18G1

+B4I.JB02
Junction Box
-X61

9
(B.25A1.L1/67.4) -X61:5

10
(B.25A1.L1/67.4) -X61:6

11
WH
BN
BU
C B.25A1.P1-W62 C
Original Cable
M12 4x0,34

+B.Local.25
Hydraulic
expressly agreed to by ANDRITZ AG or one of its affiliates.

D 0V D
1
2
4

contact

-PS
HYDAC
VR2.5LEM.1/-4MO

..1.25 bar
POS 5.21
E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Hydraulic Panel Project: RECYCLING-PRODUCTS Function Unit: B.25A1.P1
Created: Prettner Diff Pressure Oil Filter High Project no.: PDS Location:
Checked: Pereira-Perez / 05.03.2020 Circuit diagram Customer: RECYCLING-STANDARD Page: 68 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:45:08
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|25|A1|Z4|V1|PFSS.69 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC01
MCC Cabinet
Pusher FWD Command = 1 Pusher REV Command = 1 Closing Pressure

(B4I.MCC01/19.6)
(B4I.MCC01/19.2)
RQ 4x120VDC-230VAC RQ 4x120VDC-230VAC ET200SP, 2AO, 2xI ST
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

-P3:2a Ref.: (27.5) Ref.: (27.5) -P3:2a Ref.: (27.6)


A (B4I.MCC01/19.5) (.2) A
-M:8c Label: -A01-52 Label: -A01-52 Label: -A01-70
(B4I.MCC01/19.2) Loc.: Loc.: Loc.:
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

Sort: DO Sort: DO Sort: AO


Q312.0 Q312.1 QW1500
DO25A1V1_OYB DO25A1V1_OYA AO25A1V1_OY

-P4:1c
-M:7c
1 3 5 1 3 5

RQ0+

RQ1+
1

1
5
?
RQ0-

RQ1-
-KF1 -KF2

Q0+
Q0-
14

15
-X71-JB02 (.2) (.3)
2 4 6 2 4 6
A1 SIEMENS A1 SIEMENS
3RT2015-1BB42 3RT2015-1BB42
-KF1 3 kW -KF2 3 kW
-X71-JB02 -X91

1
2

4
A2 A2

B B

1
2

4
+B4I.JB02-W71 +B4I.JB02-W91

Oelflex Classic 110 BK Oelflex Classic 110 BK CY


18G1 4x1

+B4I.JB02
Junction Box
-X71

3
2

4
-X71:6 (B.25A1.V2/70.3)
-X91

1
2
3
4
5
6
PE

PE

PE
GNYE

GNYE

GNYE
1
2

1
2

1
2
3
4
5
6
C B.25A1.V1-W71 B.25A1.V1-W72 B.25A1.V1-W91 C
Original Cable Original Cable Original Cable
3x0,75 3x0,75 7G0,75

+B.Local.25
Hydraulic
expressly agreed to by ANDRITZ AG or one of its affiliates.

D D

A +24VDC
PE

PE
1
2

1
2
B 0V

A
B

E
F
G
C
D
-OY
4 2
1 2 1 2 C
(.4) (.5) A1 B1 A
3 4 3 4 -OV D +S (4-20)
5 6 5 6
A2 1 3 B2
E -S
12 11 12 11 B F
? ?
G ground
4/3-Way Valve I/P Transducer
POS 4.20 PARKER POS 2.13 PARKER
E D3W004CNJW RE06M21T2V1R030 E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Hydraulic Panel Project: RECYCLING-PRODUCTS Function Unit: B.25A1.V1
Created: Prettner Pusher Project no.: HS Location:
Checked: Pereira-Perez / 05.03.2020 Circuit diagram Customer: RECYCLING-STANDARD Page: 69 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:45:10
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|25|A1|Z4|V2|PFSS.70 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC01
MCC Cabinet
Open Service Hatch = 1 Close Service Hatch = 1

RQ 4x120VDC-230VAC RQ 4x120VDC-230VAC
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

-P4:1d Ref.: (27.3) Ref.: (27.3)


A (B4I.MCC01/19.6) A
-M:3c Label: -A01-50 Label: -A01-50
(B4I.MCC01/19.2) Loc.: Loc.:
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

Sort: DO Sort: DO
21
Q310.2 Q310.1
B.20A1-M1.Local.20-FC1
DO25A1V2_OYA DO25A1V2_OYB
(B.20A1-M1B.Local.20/40.2)
22

6
RQ2+

RQ1+
RQ2-

RQ1-
21
-A01-51:6
B.20A1-M2.Local.20-FC2 (B.25A1.V6/73.3)
(B.20A1-M2B.Local.20/41.2) -X71-JB02

3
4

5
22

B B

3
4

5
+B4I.JB02-W71

Oelflex Classic 110 BK


18G1

+B4I.JB02
Junction Box
-X71

7
6

8
(B.25A1.V1/69.5) -X71:4 -X71:10 (B.25A1.V3/71.3)

PE1

PE2
GNYE

GNYE
1
2

1
2
C B.25A1.V2-W71 B.25A1.V2-W72 C
Original Cable Original Cable
3x0,75 3x0,75

+B.Local.25
Hydraulic
expressly agreed to by ANDRITZ AG or one of its affiliates.

D D
PE

PE
1
2

1
2

-OY
4 2
A1 B1

A2 1 3 B2

4/3-Way Valve
POS 3.10 PARKER
E D1VW004CNJW91 E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Hydraulic Panel Project: RECYCLING-PRODUCTS Function Unit: B.25A1.V2
Created: Prettner Service Hatch Project no.: HS Location:
Checked: Pereira-Perez / 05.03.2020 Circuit diagram Customer: RECYCLING-STANDARD Page: 70 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:45:12
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|25|A1|Z4|V3|PFSS.71 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC01
MCC Cabinet
Close Screen Basket = 1 Open Screen Basket = 1

RQ 4x120VDC-230VAC RQ 4x120VDC-230VAC
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

Ref.: (27.4) Ref.: (27.3)


A Label: -A01-51 Label: -A01-50
A
Loc.: Loc.:
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

Sort: DO Sort: DO
Q311.0 Q310.3
DO25A1V3_OYB DO25A1V3_OYA

8
RQ0+

RQ3+
RQ0-

RQ3-
-A01-50:1
(B.25A1.V6/73.4)

-X71-JB02

7
B B

7
+B4I.JB02-W71

Oelflex Classic 110 BK


18G1

+B4I.JB02
Junction Box

11
-X71

9
10

12
(B.25A1.V2/70.4) -X71:8 -X71:14 (B.25A1.V5/72.3)

PE1

PE2
GNYE

GNYE
1
2

1
2
C B.25A1.V3-W71 B.25A1.V3-W72 C
Original Cable Original Cable
3x0,75 3x0,75

+B.Local.25
Hydraulic
expressly agreed to by ANDRITZ AG or one of its affiliates.

D D
PE

PE
1
2

1
2

-OY
4 2
A1 B1

A2 1 3 B2

4/3-Way Valve
POS 3.20 PARKER
E D1VW004CNJW91 E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Hydraulic Panel Project: RECYCLING-PRODUCTS Function Unit: B.25A1.V3
Created: Prettner Screen Basket Project no.: HS Location:
Checked: Pereira-Perez / 05.03.2020 Circuit diagram Customer: RECYCLING-STANDARD Page: 71 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:45:13
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|25|A1|Z4|V5|PFSS.72 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC01
MCC Cabinet
Close Reject Hatch = 1 Open Reject Hatch = 1

RQ 4x120VDC-230VAC RQ 4x120VDC-230VAC
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

Ref.: (27.4) Ref.:


A A
-P3:1c Label: -A01-51 Label: -A01-51
(B4I.MCC01/19.5) Loc.: Loc.:
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

Sort: DO Sort: DO
Q311.2 Q311.3
DO25A1V5_OYB DO25A1V5_OYA

8
RQ2+

RQ3+
RQ2-

RQ3-
-X71-JB02

9
B B

9
+B4I.JB02-W71

Oelflex Classic 110 BK


18G1

+B4I.JB02
Junction Box

13

15
-X71

14

16
(B.25A1.V3/71.4) -X71:12 -X71:18 (B.25A1.V6/73.3)

PE1

PE2
GNYE

GNYE
1
2

1
2
C B.25A1.V5-W71 B.25A1.V5-W72 C
Original Cable Original Cable
3x0,75 3x0,75

+B.Local.25
Hydraulic
expressly agreed to by ANDRITZ AG or one of its affiliates.

D D
PE

PE
1
2

1
2

-OY
4 2
A1 B1

A2 1 3 B2

4/3-Way Valve
POS 3.30 PARKER
E D1VW004CNJW91 E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Hydraulic Panel Project: RECYCLING-PRODUCTS Function Unit: B.25A1.V5
Created: Prettner Reject Hatch Project no.: HS Location:
Checked: Pereira-Perez / 05.03.2020 Circuit Diagram Customer: RECYCLING-STANDARD Page: 72 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:45:15
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|25|A1|Z4|V6|PFSS.73 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC01
MCC Cabinet
Lock Pusher = 1 Lock Service Hatch = 1

RQ 4x120VDC-230VAC RQ 4x120VDC-230VAC
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

Ref.: (27.4) Ref.: (27.3)


A Label: -A01-51 Label: -A01-50
A
Loc.: Loc.:
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

Sort: DO Sort: DO
Q311.1 Q310.0
DO25A1V6_OYB DO25A1V6_OYA

5
RQ1+

RQ0+
RQ1-

RQ0-
-A01-50:6 -A01-51:5
(B.25A1.V2/70.4) (B.25A1.V3/71.3)

10

11
-X71-JB02

B B

10

11
+B4I.JB02-W71

Oelflex Classic 110 BK


18G1

+B4I.JB02
Junction Box

17

19
-X71

18

20
(B.25A1.V5/72.4) -X71:16 -X71:22 (B.25A1.V7/75.3)

PE1

PE2
GNYE

GNYE
1
2

1
2
C B.25A1.V6-W71 B.25A1.V6-W72 C
Original Cable Original Cable
3x0,75 3x0,75

+B.Local.25
Hydraulic
expressly agreed to by ANDRITZ AG or one of its affiliates.

D D
PE

PE
1
2

1
2

-OY
4 2
A1 B1

Y1 1 3
Y2
A2 B2

4/2-Way Valve
POS 3.40 PARKER
E D1VW020DNJW91 E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Hydraulic Panel Project: RECYCLING-PRODUCTS Function Unit: B.25A1.V6
Created: Prettner Lock Pusher/Service Hatch Project no.: HS Location:
Checked: Pereira-Perez / 05.03.2020 Circuit diagram Customer: RECYCLING-STANDARD Page: 73 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:45:16
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|20|A6|Z4|L1|PFSS.74 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC01
MCC Cabinet
Level Low = 0

ET200SP 8-DI ST
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

Ref.: (26.5)
A Label: -A01-32
A
Loc.:
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

Sort: DI
I302.2
DI20A6L1_LS

3
DI2
(B.20A6.X1B4I.MCC01/66.4) -X61-JB01:26

B B

C C
expressly agreed to by ANDRITZ AG or one of its affiliates.

D D

E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Greasing Unit Project: RECYCLING-PRODUCTS Function Unit: B.20A6.L1
Created: Prettner Level Low Project no.: LS Location:
Checked: Pereira-Perez / 05.03.2020 Circuit diagram Customer: RECYCLING-STANDARD Page: 74 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:45:17
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|25|A1|Z4|V7|PFSS.75 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC01
MCC Cabinet
Release Reject Hatch = 1 Lock Reject Hatch = 1

RQ 4x120VDC-230VAC RQ 4x120VDC-230VAC
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

Ref.: (27.5) Ref.: (27.5)


A A
-P3:2a Label: -A01-52 Label: -A01-52
(B.25A1.V1/69.4) Loc.: Loc.:
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

Sort: DO Sort: DO
Q312.2 Q312.3
DO25A1V7_OYA DO25A1V7_OYB

8
RQ2+

RQ3+
RQ2-

RQ3-
13
12
-X71-JB02

B B

12

13
+B4I.JB02-W71

Oelflex Classic 110 BK


18G1

+B4I.JB02
Junction Box

21

23
-X71

22

24
(B.25A1.V6/73.4) -X71:20

PE1

PE2
GNYE

GNYE
1
2

1
2
C B.25A1.V7-W71 B.25A1.V7-W72 C
Original Cable Original Cable
3x0,75 3x0,75

+B.Local.25
Hydraulic
expressly agreed to by ANDRITZ AG or one of its affiliates.

D D
PE

PE
1
2

1
2

-OY
4 2
A1 B1

Y1 1 3
Y2
A2 B2

4/2-Way Valve
POS 3.50 PARKER
E D1VW020DNJW91 E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Hydraulic Panel Project: RECYCLING-PRODUCTS Function Unit: B.25A1.V7
Created: Prettner Lock Reject Hatch Project no.: HS Location:
Checked: Pereira-Perez / 05.03.2020 Circuit diagram Customer: RECYCLING-STANDARD Page: 75 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:45:19
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|25|E1|H1|E|PFSS.76 Final date of print: 30.03.2020

1 2 3 4 5 6 7
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

A A
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

B B
(20.6)

(20.6)

(20.6)
-X21:PE
-X21:1

-X21:2

C C

+B4I.JB02
Junction Box
expressly agreed to by ANDRITZ AG or one of its affiliates.

PE

-X21
1

GNYE
1

B.25E1-H1-W2
D Original cable
D
3x1,5

+B.Local.25
Hydraulic
L N PE

B.25E1-H1

0.5 kW
POS 1.57
E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Hydraulic Heater Project: RECYCLING-PRODUCTS Function Unit: B.25E1-H1
Created: Prettner MCC Project no.: M Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 Circuit diagram Customer: RECYCLING-STANDARD Page: 76 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:45:20
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|25|F1|M1|E|PFSS.77 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC01
Command Start =
MCC Cabinet
MCC Ready = 1 Running Feedback = 1 1

.MCC02-L1 .MCC02-L1 ET200SP 8-DI ST ET200SP 8-DI ST ET200SP 8-DO


(18.7) (B.25P1-M1/78.2)
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

.MCC02-L2 .MCC02-L2 Ref.: (26.6) Ref.: (26.5) Ref.: (27.3)


A (18.7) (B.25P1-M1/78.2) A
.MCC02-L3 .MCC02-L3 Label: -A01-33 Label: -A01-32 Label: -A01-41
(18.7) (B.25P1-M1/78.2) Loc.: Loc.: Loc.:
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

Sort: DI Sort: DI Sort: DO


I303.0 I302.7 Q301.0
DI25F1M1_RDY DI25F1M1_FBK DO25F1M1_CO

1 3 5 21 1_13 13 21

1
DI0

DI7

DO0
-FC1 22 1_14 14 22
I>> I>> I>>

?
(.5)
SIEMENS
3RV2011-1EA15 2 4 6
2.8-4 A
3.7 A

B B

1 3 5
-QA1
(.6) 13 13 A1
2 4 6 -FC1 -QA1
-QA1
(.2) (.6)
14 14 A2
SIEMENS
3RT2015-1BB41

C C

-P1:5a
(19.3)
-M:2c
(19.2)
expressly agreed to by ANDRITZ AG or one of its affiliates.

PE

-X1
1
2
3

GNYE
1
2
3

B.25F1-M1-W01
D Oelflex Classic 110 BK
D
4G2,5

+B.Local.25
Hydraulic
U1 N W1 PE

M
3~ (.2)
1 2
3 4

5 6
B.25F1-M1
1.1 kW 13 14
(.5)
3.7 A
E POS 5.00 E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Hydraulic Cooler Project: RECYCLING-PRODUCTS Function Unit: B.25F1-M1
Created: Prettner MCC Project no.: M Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 Circuit diagram Customer: RECYCLING-STANDARD Page: 77 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:45:22
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|25|P1|M1|E1|PFSS.78 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC01
Running Feedback Command Start =
MCC Cabinet
MCC Ready = 1 =1 1
.MCC02-L1
(B.25F1-M1/77.3)
.MCC02-L2 ET200SP 8-DI ST ET200SP 8-DI ST ET200SP 8-DO
(B.25F1-M1/77.3)
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

.MCC02-L3 Ref.: (26.6) Ref.: (26.6) Ref.: (27.3)


A (B.25F1-M1/77.3) Label: -A01-33 Label: -A01-33 Label: -A01-41
A
Loc.: Loc.: Loc.:
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

Sort: DI Sort: DI Sort: DO


I303.6 I303.5 Q301.1
DI25P1M1_RDY DI25P1M1_FBK DO25P1M1_CO

1 3 5 13 21

2
DI6

DI5

DO1
-FC1 14 22
I>> I>> I>>

?
(.5)
SIEMENS
3RV2021-4DA15 2 4 6
18-25 A
21 A

B B

1 3 5
-QA1
(.6) 13 13 A1
2 4 6 -FC1 -QA1
-QA1
(.2) (.6)
14 14 A2
SIEMENS
3RT2026-1BB40

C C

-P1:5b
(19.3)
-M:2c
(B.25F1-M1/77.6)
expressly agreed to by ANDRITZ AG or one of its affiliates.

PE

-X1
1
2
3

GNYE
1
2
3

B.25P1-M1-W01
D Oelflex Classic 110 BK
D
4G6

+B.Local.25
Hydraulic
U1 V1 W1 PE

M
3~ (.2)
1 2

3 4
5 6
POS 2.09
B.25P1-M1 13 14
(.5)
11 kW 21 22
?
20.44 A
E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Hydraulic Pump Project: RECYCLING-PRODUCTS Function Unit: B.25P1-M1
Created: Prettner MCC Project no.: M Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 Circuit diagram Customer: RECYCLING-STANDARD Page: 78 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:45:23
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|30|H1|M1|E|PFSS.79 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC02
Power Distribution
-3L1
(B4I.MCC02/17.7)
-3L2
(B4I.MCC02/17.7)
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

-3L3
A (B4I.MCC02/17.7) A
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

1 3 5 13 21 33 33 1 3 5 13 21
B.20A1-M1.Local.20-KF3 B.20A1-M1.Local.20-KF4
(B.00A01.X2/22.4) (B.00A01.X2/22.5)
.MCC01-P1:2a
-FC1 14 22 (B4I.MCC01/19.3) 34 34 -FC2 14 22
I>> I>> I>> .MCC01-M:5a
? (B4I.MCC01/19.2) I>> I>> I>>
(.3)

?
(.3)
SIEMENS SIEMENS
3RV2011-1JA15 2 4 6 2 4 6
-TA1:31 -TA1:XPOW:1 3RV2011-0CA15
7-10 A (.5) (.2) 0.18-0.25 A
-QA3:A2 (.5) (.2) -TA1:XPOW:2
B B
Profinet Interface
-TA1 L1 L2 L3 PE 1 2 1 2 3 4 5 6 7 1 2 3 4 1 2 3 1 2 3 4 X205 X13 X12
33 31
SUPPLY

AO1

AO2

OUT1

IN1

IN2
+24VI

GND

AGND

AI1+

AI2+

AGND

AGND

BGND

SGND

Memory unit

Safety functions mod.


+VREF

-VREF

AI1-

AI2-

Control panel
-TA1 1 3 5
(.2) -QA3

FENA-21
XPOW XAI XAO XD2D XSTO
32
ABB (.5)
ACS880-01-017A-3 +J400+K475 2 4 6
A1

Address:
? ? ? XD24 XDI XDIO
R+/UDC+

XRO1 XRO2 XRO3

DIOGND
DICOM
+24VD

+24VD
-QA3

DIO1

DIO2
DIIL

DI1

DI2

DI3

DI4

DI5

DI6
PE
R-

MOTOR
A2
U V W PE R- R+ PE 11 12 13 21 22 23 31 32 33 1 2 3 4 5 1 2 3 4 5 6 1 2 ETHETH SIEMENS
3RT2015-1BB41

C C
13 13 .MCC01-W61
-FC1 -FC2 Ethernet Cable
Eth -A06:P10
(.2) (.6) (B4I.MCC01/29.4)
14 14
expressly agreed to by ANDRITZ AG or one of its affiliates.

PE
PE

PE
-X11
1
2

-X1 -X2
1
2
3

1
2
GNYE

GNYE
GY
BN
BK

1
2

1
2
B.30H1-M1-W01 B.30H1-M1-W11 B.30H1-M1-W21
D NYCY Oelflex Classic 110 BK CY Oelflex Classic 110 BK
D
4 x 4 RE/ 4 2x1 3G2,5

U1 V1 W1 PE 1 2
(.6)
3 4
M 5 6 1
3~ 1
ϑ ϑ ϑ 13 14 -MB2 PE
?
2
magnetic brake 2

B.30H1-M1
5.5 kW
E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Discharge Conveyor 1 Project: RECYCLING-PRODUCTS Function Unit: B.30H1-M1
Created: Prettner MCC Project no.: M Location:
Checked: Pereira-Perez / 05.03.2020 Circuit diagram Customer: RECYCLING-STANDARD Page: 79 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
16:45:25
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|30|H1|Z4|S1|PFSS.80 Final date of print: 30.03.2020

1 2 3 4 5 6 7

+B4I.MCC01
MCC Cabinet
Speed Low = 0

ET200SP 8-DI ST
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the

Ref.: (26.6)
A Label: -A01-34
A
Loc.:
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those

Sort: DI
I304.0
DI30H1S1_SS

1
DI0
-X62-JB01

7
B B

7
+B4I.JB01-W62

Oelflex Classic 110 BK


12G1

+B4I.JB01
Junction Box

45
-X61:41 -X61
(B.20A6.X1/66.3)

46
(B.20A6.X1/66.4) -X61:42

47
1
2
3
C B.30H1.S1-W61 C
Oelflex Classic 110 BK
4G1

+B.Local.30
Discharge
expressly agreed to by ANDRITZ AG or one of its affiliates.

D D
1
3
4

-SS

G OPTION 2
E E

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Discharge Conveyor 1 Project: RECYCLING-PRODUCTS Function Unit: B.30H1.S1
Created: Prettner Speed Low Project no.: SS Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 Circuit diagram Customer: RECYCLING-STANDARD Page: 80 / 133
Standard: EN 60617 Order: Draw. no.: 508627696_EN_0
1 2 3 4 5 6 7
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|CB01|11|X41|ET-KLP.81

16:45:26
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Final date of print: 30.03.2020

Legend
+B4I.CB01-W41, Oelflex Classic 110 BK 3G1 / Ø 6.0mm

Connection input-output: Bridges:


Connection / Bridge GND Terminal Ridge bridge
Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket

Terminal strip

Internal connected device +B4I.CB01-X41 External connected device


Unit / Location Device Conn. Int. Symbol Ext. Label Bridges Reference Unit / Location Device Conn.
1 +B4I.MCC01 -X41-CP01 1 1 (B4I.CB016/24.2) +B4I.CB01 -TP1 L+
2 +B4I.MCC01 -X41-CP01 2 2 (B4I.CB016/24.2) +B4I.CB01 -TP1 L-
+B4I.CB01 -AF2 L 3 (B4I.CB016/24.4)
+B4I.CB01 -AF2 N 4 (B4I.CB016/24.4)
5 (B4I.CB016/24.6)
6 (B4I.CB016/24.6)
+B4I.CB016 -A3 + 7 (B4I.CB016/24.7)
+B4I.CB016 -A3 - 8 (B4I.CB016/24.7) +B4I.CB01 -X41 PE
PE (B4I.CB016/24.4) +B4I.CB01 -AF2 PE
PE (B4I.CB016/24.7) +B4I.CB01 -X41 8

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 MCC Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner Local Control Panel 1 Project no.: Location: +B4I.CB01
Checked: Pereira-Perez / 05.03.2020 Terminals - Terminal diagram Customer: RECYCLING-STANDARD Page: 1 / 133 81 / 133
Standard: Order: Draw. no.:
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|CB01|11|X61|ET-KLP.82

16:45:27
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Final date of print: 30.03.2020

Legend
+B4I.CB01-W12, Oelflex Classic 110 BK 34G1 / Ø 15.9mm

Connection input-output: Bridges:


Connection / Bridge GND Terminal Ridge bridge
Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket

Terminal strip
Manufacturer: PHOENIX CONTACT

Internal connected device +B4I.CB01-X61 External connected device


Unit / Location Device Conn. Int. Symbol Ext. Label Type Bridges Reference Unit / Location Device Conn.
1 +B4I.MCC01 -X61-CP01 1 1 ST 2,5 (B.00A02.H2/34.3) B.00A02.H2 +B4I.CB01 -S1 13
2 +B4I.MCC01 -X61-CP01 2 2 ST 2,5 (B.00A02.H2/34.3) B.00A02.H2 +B4I.CB01 -S1 14
3 +B4I.MCC01 -X61-CP01 3 3 ST 2,5 (B.00A02.H2/34.4) B.00A02.H2 +B4I.CB01 -S2 12
4 +B4I.MCC01 -X61-CP01 4 4 ST 2,5 (B.00A02.H2/34.5) B.00A02.H2 +B4I.CB01 -S1 2
5 +B4I.MCC01 -X61-CP01 5 5 ST 2,5 (B.00A02.H2/34.5) B.00A02.H2 +B4I.CB01 -S1 1
6 +B4I.MCC01 -X61-CP01 6 6 ST 2,5 (B.00A02.H3/35.3) B.00A02.H3 +B4I.CB01 -S1 14
7 +B4I.MCC01 -X61-CP01 7 7 ST 2,5 (B.00A02.H3/35.5) B.00A02.H3 +B4I.CB01 -S1 1
8 +B4I.MCC01 -X61-CP01 8 8 ST 2,5 (B.00A02.H4/36.3) B.00A02.H4 +B4I.CB01 -S1 12
9 +B4I.MCC01 -X61-CP01 9 9 ST 2,5 (B.00A02.H4/36.4) B.00A02.H4 +B4I.CB01 -S1 22
10 +B4I.MCC01 -X61-CP01 10 10 ST 2,5 (B.00A02.H4/36.5) B.00A02.H4 +B4I.CB01 -S2 13
11 +B4I.MCC01 -X61-CP01 11 11 ST 2,5 (B.00A02.H6/37.3) B.00A02.H6 +B4I.CB01 -S1 14
12 +B4I.MCC01 -X61-CP01 12 12 ST 2,5 (B.00A02.H6/37.4) B.00A02.H6 +B4I.CB01 -S1 24
13 +B4I.MCC01 -X61-CP01 13 13 ST 2,5 (B.20A1.H2/44.4) B.20A1.H2 +B4I.CB01 -S1 14
14 +B4I.MCC01 -X61-CP01 14 14 ST 2,5 (B.20A1.H2/44.5) B.20A1.H2 +B4I.CB01 -S1 24
15 +B4I.MCC01 -X61-CP01 15 15 ST 2,5 (B.20A2.H1/54.3) B.20A2.H1 +B4I.CB01 -S1 14
16 +B4I.MCC01 -X61-CP01 16 16 ST 2,5 (B.20A2.H1/54.4) B.20A2.H1 +B4I.CB01 -S1 24
17 +B4I.MCC01 -X61-CP01 17 17 ST 2,5 (B.20A3.H1/59.3) B.20A3.H1 +B4I.CB01 -S1 14
18 +B4I.MCC01 -X61-CP01 18 18 ST 2,5 (B.20A3.H1/59.4) B.20A3.H1 +B4I.CB01 -S1 24
19 +B4I.MCC01 -X61-CP01 19 19 ST 2,5 (B.00A02.X12B4I.LCP01/32.3) B.00A02.X12 +B4I.LCP01 -X1 1
20 +B4I.MCC01 -X61-CP01 20 20 ST 2,5 (B.00A02.X12B4I.LCP01/32.4) B.00A02.X12 +B4I.LCP01 -X1 2
21 +B4I.MCC01 -X61-CP01 21 21 ST 2,5 (B.00A02.X12B4I.LCP01/32.5) B.00A02.X12 +B4I.LCP01 -X1 3
22 +B4I.MCC01 -X61-CP01 22 22 ST 2,5 (B.00A02.H7/30.3) B.00A02.H7 -SF L1
23 +B4I.MCC01 -X61-CP01 23 23 ST 2,5 (B.00A02.H7/30.3) B.00A02.H7 -SF L2
24 +B4I.MCC01 -X61-CP01 24 24 ST 2,5 (B.00A02.H7/30.4) B.00A02.H7 -SF T1
25 +B4I.MCC01 -X61-CP01 25 25 ST 2,5 (B.00A02.H7/30.4) B.00A02.H7 -SF T2

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 MCC Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner Local Control Panel 1 Project no.: Location: +B4I.CB01
Checked: Pereira-Perez / 05.03.2020 Terminals - Terminal diagram Customer: RECYCLING-STANDARD Page: 1 / 133 82 / 133
Standard: Order: Draw. no.:
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|CB01|11|X10|ET-KLP.83

16:45:28
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Final date of print: 30.03.2020

Legend
B.00A02.H1-W62, Oelflex Classic 110 BK 5G1 / Ø 7.1mm

Connection input-output: Bridges:


Connection / Bridge GND Terminal Ridge bridge
Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket

Terminal strip
Manufacturer: PHOENIX CONTACT

Internal connected device +B4I.CB01-X10 External connected device


Unit / Location Device Conn. Int. Symbol Ext. Label Type Bridges Reference Unit / Location Device Conn.
1 +B4I.MCC01 -X10 7 1 ST 2,5 (B.00A02.H1/23.3) B.00A02.H1 +B4I.CB01 -S1 11
2 +B4I.MCC01 -X10 8 2 ST 2,5 (B.00A02.H1/23.3) B.00A02.H1 +B4I.CB01 -S1 21
3 +B4I.MCC01 -X10 9 3 ST 2,5 (B.00A02.H1/23.4) B.00A02.H1 +B4I.CB01 -S1 12
4 +B4I.MCC01 -X10 10 4 ST 2,5 (B.00A02.H1/23.4) B.00A02.H1 +B4I.CB01 -S1 22
PE ST 2,5-PE -

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 MCC Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner Local Control Panel 1 Project no.: Location: +B4I.CB01
Checked: Pereira-Perez / 05.03.2020 Terminals - Terminal diagram Customer: RECYCLING-STANDARD Page: 1 / 133 83 / 133
Standard: Order: Draw. no.:
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|CB02|10|X61|ET-KLP.84

16:45:29
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Final date of print: 30.03.2020

Legend
+B4I.CB02-W61, Oelflex Classic 110 BK 12G1 / Ø 10.5mm

Connection input-output: Bridges:


Connection / Bridge GND Terminal Ridge bridge
Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket

Terminal strip
Manufacturer: PHOENIX CONTACT

Internal connected device +B4I.CB02-X61 External connected device


Unit / Location Device Conn. Int. Symbol Ext. Label Type Bridges Reference Unit / Location Device Conn.
1 +B4I.MCC01 -X61-CP02 1 1 ST 2,5 (B.20A4.H1/63.3) B.20A4.H1 +B4I.CB02 -S1 13
2 +B4I.MCC01 -X61-CP02 2 2 ST 2,5 (B.20A4.H1/63.3) B.20A4.H1 +B4I.CB02 -S1 14
3 +B4I.MCC01 -X61-CP02 3 3 ST 2,5 (B.20A4.H1/63.4) B.20A4.H1 +B4I.CB02 -S1 24
4 +B4I.MCC01 -X61-CP02 4 4 ST 2,5 (B.20A5.H1/65.3) B.20A5.H1 +B4I.CB02 -S1 14
5 +B4I.MCC01 -X61-CP02 5 5 ST 2,5 (B.20A5.H1/65.4) B.20A5.H1 +B4I.CB02 -S1 24
PE ST 2,5-PE -
6 +B4I.MCC01 -X61-CP02 6 6 ST 2,5 (B.20A1.H3/45.4) B.20A1.H3 +B4I.CB02 -S1 14
7 +B4I.MCC01 -X61-CP02 7 7 ST 2,5 (B.20A1.H3/45.5) B.20A1.H3 +B4I.CB02 -S1 34
8 +B4I.MCC01 -X61-CP02 8 8 ST 2,5 (B.20A1.H3/45.5) B.20A1.H3 +B4I.CB02 -S1 44
9 +B4I.MCC01 -X61-CP02 9 9 ST 2,5 (B.20A2.H2/55.3) B.20A2.H2 +B4I.CB02 -S1 14
10 +B4I.MCC01 -X61-CP02 10 10 ST 2,5 (B.20A2.H2/55.4) B.20A2.H2 +B4I.CB02 -S1 24

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 MCC Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner Local Control Panel 2 Project no.: Location: +B4I.CB02
Checked: Pereira-Perez / 05.03.2020 Terminals - Terminal diagram Customer: RECYCLING-STANDARD Page: 1 / 133 84 / 133
Standard: Order: Draw. no.:
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|CB02|10|X10|ET-KLP.85

16:45:30
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Final date of print: 30.03.2020

Legend
B.00A02.H1-W61, Oelflex Classic 110 BK 5G1 / Ø 7.1mm

Connection input-output: Bridges:


Connection / Bridge GND Terminal Ridge bridge
Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket

Terminal strip
Manufacturer: PHOENIX CONTACT

Internal connected device +B4I.CB02-X10 External connected device


Unit / Location Device Conn. Int. Symbol Ext. Label Type Bridges Reference Unit / Location Device Conn.
1 +B4I.MCC01 -X10 3 1 ST 2,5 (B.00A02.H1B4I.CB01/23.2) B.00A02.H1 +B4I.CB02 -S2 11
2 +B4I.MCC01 -X10 4 2 ST 2,5 (B.00A02.H1B4I.CB01/23.2) B.00A02.H1 +B4I.CB02 -S2 21
3 +B4I.MCC01 -X10 5 3 ST 2,5 (B.00A02.H1B4I.CB01/23.2) B.00A02.H1 +B4I.CB02 -S2 12
4 +B4I.MCC01 -X10 6 4 ST 2,5 (B.00A02.H1B4I.CB01/23.2) B.00A02.H1 +B4I.CB02 -S2 22

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 MCC Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner Local Control Panel 2 Project no.: Location: +B4I.CB02
Checked: Pereira-Perez / 05.03.2020 Terminals - Terminal diagram Customer: RECYCLING-STANDARD Page: 1 / 133 85 / 133
Standard: Order: Draw. no.:
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|CB02|10|X71|ET-KLP.86

16:45:31
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Final date of print: 30.03.2020

Legend
+B4I.CB02-W62, Oelflex Classic 110 BK 4G1 / Ø 7.2mm

Connection input-output: Bridges:


Connection / Bridge GND Terminal Ridge bridge
Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket

Terminal strip
Manufacturer: PHOENIX CONTACT

Internal connected device +B4I.CB02-X71 External connected device


Unit / Location Device Conn. Int. Symbol Ext. Label Type Bridges Reference Unit / Location Device Conn.
1 +B4I.MCC01 -X71-CP02 1 1 ST 2,5 (B.20A4.G3B4I.MCC01/62.7) B.20A4.G3 +B4I.CB02 -H1 1
2 +B4I.MCC01 -X71-CP02 2 2 ST 2,5 (B.20A4.G3B4I.MCC01/62.7) B.20A4.G3 +B4I.CB02 -H1 2

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 MCC Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner Local Control Panel 2 Project no.: Location: +B4I.CB02
Checked: Pereira-Perez / 05.03.2020 Terminals - Terminal diagram Customer: RECYCLING-STANDARD Page: 1 / 133 86 / 133
Standard: Order: Draw. no.:
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.A|JB01|11|X61|ET-KLP.87

16:45:31
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Final date of print: 30.03.2020

Legend
+B4I.JB01-W61, Oelflex Classic 110 BK 34G1 / Ø 15.9mm

+B4I.JB01-W62, Oelflex Classic 110 BK 12G1 / Ø 16.9mm

B.20A2.G1-W61, Oelflex Classic 110 BK 4G1 / Ø 7.2mm

B.20A2.G2-W61, Oelflex Classic 110 BK 4G1 / Ø 7.2mm

B.20A3.G2-W61, Oelflex Classic 110 BK 4G1 / Ø 7.2mm

B.20A3.G3-W61, Oelflex Classic 110 BK 4G1 / Ø 7.2mm

B.20A4.G2-W61, Oelflex Classic 110 BK 4G1 / Ø 7.2mm

B.20A4.G2-W62, Oelflex Classic 110 BK 4G1 / Ø 7.2mm


Connection input-output: Bridges:
Connection / Bridge GND Terminal Ridge bridge
Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:

B.20A3.G1-W1, Original Cable 8 x 0,34

B.20A4.G1-W1, Original Cable 8 x 0,34


Fuse Slide connection Wire-Connection
Fuse, switchable Test socket

Terminal strip
Manufacturer: PHOENIX CONTACT

Internal connected device +B4I.JB01-X61 External connected device


Unit / Location Device Conn. Int. Symbol Ext. Label Type Bridges Reference Unit / Location Device Conn.
1 +B4I.MCC01 -X61-JB01 1 1 ST 2,5 - B.20A2.G1 +B.Local.20 -GS 1 1
2 +B4I.MCC01 -X61-JB01 2 2 ST 2,5 - B.20A2.G1 +B.Local.20 -GS 3 2
3 +B4I.MCC01 -X61-JB01 3 3 ST 2,5 - B.20A2.G1 +B.Local.20 -GS 4 3
4 ST 2,5 - B.20A2.G2 +B.Local.20 -GS 1 1
5 ST 2,5 - B.20A2.G2 +B.Local.20 -GS 3 2
4 +B4I.MCC01 -X61-JB01 4 6 ST 2,5 - B.20A2.G2 +B.Local.20 -GS 4 3
7 ST 2,5 - B.20A3.G1 +B.Local.20 -GSZ A1 bn
8 ST 2,5 - B.20A3.G1 +B.Local.20 -GSZ A2 bl
5 +B4I.MCC01 -X61-JB01 5 9 ST 2,5 - B.20A3.G1 +B.Local.20 -GSZ S11 pk
6 +B4I.MCC01 -X61-JB01 6 10 ST 2,5 - B.20A3.G1 +B.Local.20 -GSZ S21 wh
7 +B4I.MCC01 -X61-JB01 7 11 ST 2,5 - B.20A3.G1 +B.Local.20 -GSZ 12 gn
8 +B4I.MCC01 -X61-JB01 8 12 ST 2,5 - B.20A3.G1 +B.Local.20 -GSZ 22 ye
9 +B4I.MCC01 -X61-JB01 9 13 ST 2,5 - B.20A3.G2 +B.Local.20 -GS 1 1
10 +B4I.MCC01 -X61-JB01 10 14 ST 2,5 - B.20A3.G2 +B.Local.20 -GS 3 2
11 +B4I.MCC01 -X61-JB01 11 15 ST 2,5 - B.20A3.G2 +B.Local.20 -GS 4 3
16 ST 2,5 - B.20A3.G3 +B.Local.20 -GS 1 1
17 ST 2,5 - B.20A3.G3 +B.Local.20 -GS 3 2
12 +B4I.MCC01 -X61-JB01 12 18 ST 2,5 - B.20A3.G3 +B.Local.20 -GS 4 3
19 ST 2,5 - B.20A4.G1 +B.Local.20 -GSZ A1 bn
20 ST 2,5 - B.20A4.G1 +B.Local.20 -GSZ A2 bl
6 +B4I.MCC01 -X62-JB01 6 21 ST 2,5 - B.20A4.G1 +B.Local.20 -GSZ S11 pk
22 ST 2,5 - B.20A4.G2 +B.Local.20 -GS1 1 1
23 ST 2,5 - B.20A4.G2 +B.Local.20 -GS1 3 2
14 +B4I.MCC01 -X61-JB01 14 24 ST 2,5 - B.20A4.G2 +B.Local.20 -GS1 4 3
25 ST 2,5 - B.20A4.G2 +B.Local.20 -GS2 1 1
26 ST 2,5 - B.20A4.G2 +B.Local.20 -GS2 3 2
15 +B4I.MCC01 -X61-JB01 15 27 ST 2,5 - B.20A4.G2 +B.Local.20 -GS2 4 3

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Machine Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner Junction Box Project no.: Location: +B4I.JB01
Checked: Pereira-Perez / 05.03.2020 Terminals - Terminal diagram Customer: RECYCLING-STANDARD Page: 1 / 133 87 / 133
Standard: Order: Draw. no.:
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.A|JB01|11|X61|ET-KLP.87

16:45:31
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Final date of print: 30.03.2020

Legend
+B4I.JB01-W61, Oelflex Classic 110 BK 34G1 / Ø 15.9mm

+B4I.JB01-W62, Oelflex Classic 110 BK 12G1 / Ø 16.9mm

B.20A4.G3-W61, Oelflex Classic 110 BK 4G1 / Ø 7.2mm

B.20A4.G3-W62, Oelflex Classic 110 BK 4G1 / Ø 7.2mm

B.30H1.S1-W61, Oelflex Classic 110 BK 4G1 / Ø 6.5mm

B.10B1.L1-W62, Oelflex Classic 110 BK 5G1 / Ø 7.1mm


Connection input-output: Bridges:

B.20A6.X1-W61, Original Cable 4G2.5 / Ø 8.9mm


Connection / Bridge GND Terminal Ridge bridge

B.20A6.X1-W41, Original Cable 3G1 / Ø 6.7mm


Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:

B.20A5.G1-W1, Original Cable 8 x 0,34

B.20A4.G1-W1, Original Cable 8 x 0,34


Fuse Slide connection Wire-Connection
Fuse, switchable Test socket

Terminal strip
Manufacturer: PHOENIX CONTACT

Internal connected device +B4I.JB01-X61 External connected device


Unit / Location Device Conn. Int. Symbol Ext. Label Type Bridges Reference Unit / Location Device Conn.
28 ST 2,5 - B.20A4.G3 +B.Local.20 -GS1 1 1
29 ST 2,5 - B.20A4.G3 +B.Local.20 -GS1 3 2
16 +B4I.MCC01 -X61-JB01 16 30 ST 2,5 - B.20A4.G3 +B.Local.20 -GS1 4 3
31 ST 2,5 - B.20A4.G3 +B.Local.20 -GS2 1 1
32 ST 2,5 - B.20A4.G3 +B.Local.20 -GS2 3 2
17 +B4I.MCC01 -X61-JB01 17 33 ST 2,5 - B.20A4.G3 +B.Local.20 -GS2 4 3
34 ST 2,5 - B.20A5.G1 +B.Local.20 -GSZ A1 bn
35 ST 2,5 - B.20A5.G1 +B.Local.20 -GSZ A2 bl
18 +B4I.MCC01 -X61-JB01 18 36 ST 2,5 - B.20A5.G1 +B.Local.20 -GSZ S11 pk
19 +B4I.MCC01 -X61-JB01 19 37 ST 2,5 - B.20A5.G1 +B.Local.20 -GSZ S21 wh
20 +B4I.MCC01 -X61-JB01 20 38 ST 2,5 - B.20A5.G1 +B.Local.20 -GSZ 12 gn
21 +B4I.MCC01 -X61-JB01 21 39 ST 2,5 - B.20A5.G1 +B.Local.20 -GSZ 22 ye
22 +B4I.MCC01 -X61-JB01 22 40 ST 2,5 - B.20A6.X1 +B.Local.20 -XC X1:1 RD
23 +B4I.MCC01 -X61-JB01 23 41 ST 2,5 - B.20A6.X1 +B.Local.20 -XC X1:2 BN
24 +B4I.MCC01 -X61-JB01 24 42 ST 2,5 - B.20A6.X1 +B.Local.20 -XC X2:1 RD
25 +B4I.MCC01 -X61-JB01 25 43 ST 2,5 - B.20A6.X1 +B.Local.20 -XC X2:2 BN
26 +B4I.MCC01 -X61-JB01 26 44 ST 2,5 - B.20A6.X1 +B.Local.20 -XC X2:3 BK
45 ST 2,5 - B.30H1.S1 +B.Local.30 -SS 1 1
46 ST 2,5 - B.30H1.S1 +B.Local.30 -SS 3 2
7 +B4I.MCC01 -X62-JB01 7 47 ST 2,5 - B.30H1.S1 +B.Local.30 -SS 4 3
48 ST 2,5 -
8 +B4I.MCC01 -X62-JB01 8 49 ST 2,5 -
1 +B4I.MCC01 -X62-JB01 1 50 ST 2,5 - B.10B1.L1 +B.Local.10 -LS2 L/+ 1
2 +B4I.MCC01 -X62-JB01 2 51 ST 2,5 - B.10B1.L1 +B.Local.10 -LS2 N/- 2
3 +B4I.MCC01 -X62-JB01 3 52 ST 2,5 - B.10B1.L1 +B.Local.10 -LS2 4 3
4 +B4I.MCC01 -X62-JB01 4 53 ST 2,5 - B.10B1.L1 +B.Local.10 -LS2 3 4
9 +B4I.MCC01 -X62-JB01 9 54 ST 2,5 - B.20A4.G1 +B.Local.20 -GSZ S21 wh
10 +B4I.MCC01 -X62-JB01 10 55 ST 2,5 - B.20A4.G1 +B.Local.20 -GSZ 12 gn
11 +B4I.MCC01 -X62-JB01 11 56 ST 2,5 - B.20A4.G1 +B.Local.20 -GSZ 22 ye
+B4I.MCC01 -X62-JB01 PE PE ST 2,5-PE - B.20A6.X1 +B.Local.20 -XC X1:PE GNYE

PE2 ST 2,5-PE -

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Machine Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner Junction Box Project no.: Location: +B4I.JB01
Checked: Pereira-Perez / 05.03.2020 Terminals - Terminal diagram Customer: RECYCLING-STANDARD Page: 2 / 133 88 / 133
Standard: Order: Draw. no.:
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.A|JB01|11|X81|ET-KLP.89

16:45:35
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Final date of print: 30.03.2020
+B4I.JB01-W81, Oelflex Classic 110 BK CY 4x0,75 / Ø 8mm

Legend
B.20A1.T1-W81, Oelflex Classic 110 BK CY 2x1 / Ø 7.4mm

B.20A1.T2-W81, Oelflex Classic 110 BK CY 2x1 / Ø 7.4mm

B.20A1.T1-W82, Oelflex Classic 110 BK CY 2x1 / Ø 7.4mm

B.20A1.T2-W82, Oelflex Classic 110 BK CY 2x1 / Ø 6.2mm


Connection input-output: Bridges:
Connection / Bridge GND Terminal Ridge bridge
Diode Opto-coupler terminal Switch bridge

B.20A1.S1-W81, Original Cable 8 x 0,25


Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket

Terminal strip
Manufacturer: PHOENIX CONTACT

Internal connected device +B4I.JB01-X81 External connected device


Unit / Location Device Conn. Int. Symbol Ext. Label Type Bridges Reference Unit / Location Device Conn.
1 +B4I.MCC01 -X81-JB01 1 1 ST 2,5 (B.20A1.S1B4I.MCC01/46.4) B.20A1.S1 +B.Local.20 -SE 2 bn
2 +B4I.MCC01 -X81-JB01 2 2 ST 2,5 (B.20A1.S1B4I.MCC01/46.4) B.20A1.S1 +B.Local.20 -SE 1 wh
3 +B4I.MCC01 -X81-JB01 3 3 ST 2,5 (B.20A1.S1B4I.MCC01/46.4) B.20A1.S1 +B.Local.20 -SE 3 gn
+B4I.MCC01 -PE PE PE ST 2,5-PE (B.20A1.S1B4I.MCC01/46.4) SH1
BR +B4I.MCC01 -X81-JB01 4 4 ST 2,5 (B.20A1.T1/47.4) B.20A1.T1 +B.Local.20 -TT s+ 1
WH +B4I.MCC01 -X81-JB01 5 5 ST 2,5 (B.20A1.T1/47.4) B.20A1.T1 +B.Local.20 -TT s- 2
+B4I.MCC01 -X81-JB01 PE PE ST 2,5-PE (B.20A1.T1/47.4) SH1
BR +B4I.MCC01 -X81-JB01 6 6 ST 2,5 (B.20A1.T2/48.4) B.20A1.T2 +B.Local.20 -TT s+ 1
WH +B4I.MCC01 -X81-JB01 7 7 ST 2,5 (B.20A1.T2/48.4) B.20A1.T2 +B.Local.20 -TT s- 2
+B4I.MCC01 -X81-JB01 PE PE ST 2,5-PE (B.20A1.T2/48.4) +B4I.JB01 PE PE
4 +B4I.MCC01 -X81-JB01 8 8 ST 2,5 (B.20A1.S1B4I.MCC01/46.4) B.20A1.S1 +B.Local.20 -SE 7 bu

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Machine Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner Junction Box Project no.: Location: +B4I.JB01
Checked: Pereira-Perez / 05.03.2020 Terminals - Terminal diagram Customer: RECYCLING-STANDARD Page: 1 / 133 89 / 133
Standard: Order: Draw. no.:
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.A|JB05|11|X21|ET-KLP.90

16:45:36
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Final date of print: 30.03.2020

Legend
+B4I.JB05-W11, Oelflex Classic 110 BK 3G2,5 / Ø 6.0mm

Connection input-output: Bridges:


Connection / Bridge GND Terminal Ridge bridge
Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket

Terminal strip
Manufacturer: PHOENIX CONTACT

Internal connected device +B4I.JB05-X21 External connected device


Unit / Location Device Conn. Int. Symbol Ext. Label Type Bridges Reference Unit / Location Device Conn.
1 +B4I.MCC01 -X21-JB05 1 1 ST 2,5 (B.20A1.G1/42.4) B.20A1.G1 +B4I.JB05 -GT 1
2 +B4I.MCC01 -X21-JB05 2 2 ST 2,5 (B.20A1.G1/42.4) B.20A1.G1 +B4I.JB05 -GT 2
GNYE +B4I.MCC01 -X21-JB05 PE 3 ST 2,5 (B.20A1.G1/42.4) B.20A1.G1 +B4I.JB05 -GT PE
4 ST 2,5 (B.20A1.G2/43.4) B.20A1.G2 +B4I.JB05 -GT 1
5 ST 2,5 (B.20A1.G2/43.4) B.20A1.G2 +B4I.JB05 -GT 2
6 ST 2,5 (B.20A1.G2/43.4) B.20A1.G2 +B4I.JB05 -GT PE
PE ST 2,5-PE -
PE ST 2,5-PE -

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Machine Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner JB Slip Montoring Project no.: Location: +B4I.JB05
Checked: Pereira-Perez / 05.03.2020 Terminals - Terminal diagram Customer: RECYCLING-STANDARD Page: 1 / 133 90 / 133
Standard: Order: Draw. no.:
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.A|JB05|11|X61|ET-KLP.91

16:45:37
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Final date of print: 30.03.2020

Legend
+B4I.JB05-W12, Oelflex Classic 110 BK 5G1 / Ø 7.1mm

Connection input-output: Bridges:


Connection / Bridge GND Terminal Ridge bridge
Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket

Terminal strip
Manufacturer: PHOENIX CONTACT

Internal connected device +B4I.JB05-X61 External connected device


Unit / Location Device Conn. Int. Symbol Ext. Label Type Bridges Reference Unit / Location Device Conn.
1 ST 2,5 (B.20A1.G1/42.4) B.20A1.G1 +B4I.JB05 -GT 3
1 +B4I.MCC01 -X61-JB05 1 2 ST 2,5 (B.20A1.G1/42.4) B.20A1.G1 +B4I.JB05 -GT 4
+B4I.JB05 -X61 5
2 +B4I.MCC01 -X61-JB05 2 3 ST 2,5 (B.20A1.G1/42.4) B.20A1.G1 +B4I.JB05 -GT 5
4 ST 2,5 (B.20A1.G2/43.4) B.20A1.G2 +B4I.JB05 -GT 3
+B4I.JB05 -X61 2 5 ST 2,5 (B.20A1.G2/43.4) B.20A1.G2 +B4I.JB05 -GT 4
3 +B4I.MCC01 -X61-JB05 3 6 ST 2,5 (B.20A1.G2/43.4) B.20A1.G2 +B4I.JB05 -GT 5

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Machine Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner JB Slip Montoring Project no.: Location: +B4I.JB05
Checked: Pereira-Perez / 05.03.2020 Terminals - Terminal diagram Customer: RECYCLING-STANDARD Page: 1 / 133 91 / 133
Standard: Order: Draw. no.:
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.A|JB05|11|X62|ET-KLP.92

16:45:38
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Final date of print: 30.03.2020

Legend
Connection input-output: Bridges:

B.20A1.G1-W71, Original Cable 4x0,75 / Ø 6.0mm

B.20A1.G1-W72, Original Cable 4x0,75 / Ø 6.0mm

B.20A1.G2-W71, Original Cable 4x0,75 / Ø 6.0mm

B.20A1.G2-W72, Original Cable 4x0,75 / Ø 6.0mm


Connection / Bridge GND Terminal Ridge bridge
Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket

Terminal strip
Manufacturer: PHOENIX CONTACT

Internal connected device +B4I.JB05-X62 External connected device


Unit / Location Device Conn. Int. Symbol Ext. Label Type Bridges Reference Unit / Location Device Conn.
B.20A1.G1 +B4I.JB05 -GT 6 1 ST 2,5 (B.20A1.G1/42.3) B.20A1.G1 +B.Local.20 -GE1 4 2
B.20A1.G1 +B4I.JB05 -GT 8 2 ST 2,5 (B.20A1.G1/42.3) B.20A1.G1 +B.Local.20 -GE1 3 3
3 ST 2,5 (B.20A1.G1/42.3)
B.20A1.G1 +B4I.JB05 -GT 10 4 ST 2,5 (B.20A1.G1/42.5) B.20A1.G1 +B.Local.20 -GE2 4 2
B.20A1.G1 +B4I.JB05 -GT 12 5 ST 2,5 (B.20A1.G1/42.5) B.20A1.G1 +B.Local.20 -GE2 3 3
B.20A1.G1 +B4I.JB05 -GT 13 6 ST 2,5 (B.20A1.G1/42.5) B.20A1.G1 +B.Local.20 -GE2 1 1
PE ST 2,5-PE (B.20A1.G1/42.5) B.20A1.G1 +B.Local.20 -GE2 GND GNYE

B.20A1.G1 +B.Local.20 -GE1 GND GNYE

B.20A1.G2 +B4I.JB05 -GT 6 7 ST 2,5 (B.20A1.G2/43.3) B.20A1.G2 +B.Local.20 -GE1 4 2


B.20A1.G2 +B4I.JB05 -GT 8 8 ST 2,5 (B.20A1.G2/43.3) B.20A1.G2 +B.Local.20 -GE1 3 3
B.20A1.G2 +B4I.JB05 -GT 9 9 ST 2,5 (B.20A1.G2/43.3) B.20A1.G2 +B.Local.20 -GE1 1 1
B.20A1.G2 +B4I.JB05 -GT 10 10 ST 2,5 (B.20A1.G2/43.5) B.20A1.G2 +B.Local.20 -GE2 4 2
B.20A1.G2 +B4I.JB05 -GT 12 11 ST 2,5 (B.20A1.G2/43.5) B.20A1.G2 +B.Local.20 -GE2 3 3
B.20A1.G2 +B4I.JB05 -GT 13 12 ST 2,5 (B.20A1.G2/43.5) B.20A1.G2 +B.Local.20 -GE2 1 1
PE ST 2,5-PE (B.20A1.G2/43.5) B.20A1.G2 +B.Local.20 -GE2 GND GNYE

B.20A1.G2 +B.Local.20 -GE1 GND GNYE

PE ST 2,5-PE -

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Machine Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner JB Slip Montoring Project no.: Location: +B4I.JB05
Checked: Pereira-Perez / 05.03.2020 Terminals - Terminal diagram Customer: RECYCLING-STANDARD Page: 1 / 133 92 / 133
Standard: Order: Draw. no.:
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.A|JB10|11|X61|ET-KLP.93

16:45:39
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Final date of print: 30.03.2020

Legend
Connection input-output: Bridges:
Connection / Bridge GND Terminal Ridge bridge
Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket

Terminal strip
Manufacturer: PHOENIX CONTACT

Internal connected device +B4I.JB10-X61 External connected device


Unit / Location Device Conn. Int. Symbol Ext. Label Type Bridges Reference Unit / Location Device Conn.
1 ST 2,5 -
2 ST 2,5 -
3 ST 2,5 -
4 ST 2,5 -
PE ST 2,5-PE -
PE ST 2,5-PE -

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Machine Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner JB Condition Monitoring Project no.: Location: +B4I.JB10
Checked: Pereira-Perez / 05.03.2020 Terminals - Terminal diagram Customer: RECYCLING-STANDARD Page: 1 / 133 93 / 133
Standard: Order: Draw. no.:
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.A|JB10|11|X81|ET-KLP.94

16:45:40
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Final date of print: 30.03.2020

Legend
+B4I.JB10-W81, Oelflex Classic 110 BK CY 4x1 / Ø 8mm

Connection input-output: Bridges:


Connection / Bridge GND Terminal Ridge bridge

B.20A1.V1-W81, Original Cable HS-AC010-20


Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket

Terminal strip
Manufacturer: PHOENIX CONTACT

Internal connected device +B4I.JB10-X81 External connected device


Unit / Location Device Conn. Int. Symbol Ext. Label Type Bridges Reference Unit / Location Device Conn.
1 +B4I.MCC01 -X81-JB10 1 1 ST 2,5 (B.20A1.V1/49.3) B.20A1.V1 +B.Local.20 -XE 1 BN
2 +B4I.MCC01 -X81-JB10 3 2 ST 2,5 (B.20A1.V1/49.4) B.20A1.V1 +B.Local.20 -XE 2 WH
3 +B4I.MCC01 -X81-JB10 5 3 ST 2,5 (B.20A1.V1/49.5) B.20A1.V1 +B.Local.20 -XE 3 BU
4 +B4I.MCC01 -X81-JB10 6 4 ST 2,5 (B.20A1.V1/49.5) B.20A1.V1 +B.Local.20 -XE 4 BK
+B4I.MCC01 -X81-JB10 PE PE ST 2,5-PE (B.20A1.V1/49.5) B.20A1.V1 +B.Local.20 -XE GND
SH1 +B4I.MCC01 -X81-JB10 PE SH1

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Machine Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner JB Condition Monitoring Project no.: Location: +B4I.JB10
Checked: Pereira-Perez / 05.03.2020 Terminals - Terminal diagram Customer: RECYCLING-STANDARD Page: 1 / 133 94 / 133
Standard: Order: Draw. no.:
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.A|JB10|11|X82|ET-KLP.95

16:45:41
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Final date of print: 30.03.2020

Legend
Connection input-output: Bridges:
+B4I.JB10-W82, Li2YCY PiMF 4x2x1,0 / Ø 13.0mm

Connection / Bridge GND Terminal Ridge bridge

B.20A1.V2-W81, Original Cable HS-AC010-20

B.20A1.V3-W81, Original Cable HS-AC010-20


Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket

Terminal strip
Manufacturer: PHOENIX CONTACT

Internal connected device +B4I.JB10-X82 External connected device


Unit / Location Device Conn. Int. Symbol Ext. Label Type Bridges Reference Unit / Location Device Conn.
1OR +B4I.MCC01 -X82-JB10 1 1 ST 2,5 (B.20A1.V2/50.4) B.20A1.V2 +B.Local.20 -XE A WH
1WH +B4I.MCC01 -X82-JB10 2 2 ST 2,5 (B.20A1.V2/50.4) B.20A1.V2 +B.Local.20 -XE B BK
+B4I.MCC01 -X82-JB10 PE PE ST 2,5-PE (B.20A1.V2/50.4) B.20A1.V2 +B.Local.20 -XE GND
2OR +B4I.MCC01 -X82-JB10 4 4 ST 2,5 (B.20A1.V3/51.4) B.20A1.V3 +B.Local.20 -XE A WH
2WH +B4I.MCC01 -X82-JB10 5 5 ST 2,5 (B.20A1.V3/51.4) B.20A1.V3 +B.Local.20 -XE B BK
+B4I.MCC01 -X82-JB10 PE PE ST 2,5-PE (B.20A1.V3/51.4) B.20A1.V3 +B.Local.20 -XE GND

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Machine Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner JB Condition Monitoring Project no.: Location: +B4I.JB10
Checked: Pereira-Perez / 05.03.2020 Terminals - Terminal diagram Customer: RECYCLING-STANDARD Page: 1 / 133 95 / 133
Standard: Order: Draw. no.:
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.H|JB02|11|X21|ET-KLP.96

16:45:41
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Final date of print: 30.03.2020

Legend
+B4I.JB02-W21, Oelflex Classic 110 BK 3G2,5 / Ø 8.1mm

Connection input-output: Bridges:


Connection / Bridge GND Terminal Ridge bridge
Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:

B.25E1-H1-W2, Original cable 3x1,5


Fuse Slide connection Wire-Connection
Fuse, switchable Test socket

Terminal strip
Manufacturer: PHOENIX CONTACT

Internal connected device +B4I.JB02-X21 External connected device


Unit / Location Device Conn. Int. Symbol Ext. Label Type Bridges Reference Unit / Location Device Conn.
1 +B4I.MCC01 -X21 1 1 ST 2,5 (B.25E1-H1B4I.MCC01/76.2) B.25E1 +B.Local.25 -H1 L 1
2 +B4I.MCC01 -X21 2 2 ST 2,5 (B.25E1-H1B4I.MCC01/76.2) B.25E1 +B.Local.25 -H1 N 2
GNYE +B4I.MCC01 -X21 PE PE ST 2,5-PE (B.25E1-H1B4I.MCC01/76.2) B.25E1 +B.Local.25 -H1 PE GNYE

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Hydraulic Panel Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner Junction Box Project no.: Location: +B4I.JB02
Checked: Pereira-Perez / 05.03.2020 Terminals - Terminal diagram Customer: RECYCLING-STANDARD Page: 1 / 133 96 / 133
Standard: Order: Draw. no.:
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.H|JB02|11|X61|ET-KLP.97

16:45:42
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Final date of print: 30.03.2020

Legend
+B4I.JB02-W61, Oelflex Classic 110 BK 18G1 / Ø 12.7mm

B.25A1.P1-W62, Original Cable M12 4x0,34 / Ø 7.1mm


Connection input-output: Bridges:
B.25A1.L1-W61, Original Cable 4x0,34 / Ø 7.1mm

B.25A1.L1-W62, Original Cable 4x0,34 / Ø 7.1mm

B.25A1.L1-W61, Original Cable 4x0,34 / Ø 7.1mm

B.25A1.L1-W62, Original Cable 4x0,34 / Ø 7.1mm


Connection / Bridge GND Terminal Ridge bridge
Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket

Terminal strip
Manufacturer: PHOENIX CONTACT

Internal connected device +B4I.JB02-X61 External connected device


Unit / Location Device Conn. Int. Symbol Ext. Label Type Bridges Reference Unit / Location Device Conn.
1 +B4I.MCC01 -X61-JB02 1 1 ST 2,5 (B.25A1.L1/67.3) B.25A1.L1 +B.Local.25 -LS A:1 BN
2 +B4I.MCC01 -X61-JB02 2 2 ST 2,5 (B.25A1.L1/67.3) B.25A1.L1 +B.Local.25 -LS A:3 BU
3 +B4I.MCC01 -X61-JB02 3 3 ST 2,5 (B.25A1.L1/67.3) B.25A1.L1 +B.Local.25 -LS A:2 WH
PE ST 2,5-PE (B.25A1.L1/67.4) +B4I.JB02 -X61 PE SH1
SH1 +B4I.JB02 -X61 PE
4 +B4I.MCC01 -X61-JB02 4 4 ST 2,5 (B.25A1.L1/67.4) B.25A1.L1 +B.Local.25 -LS A:4 BK
5 ST 2,5 (B.25A1.L1/67.4) B.25A1.L1 +B.Local.25 -LS B:1 BN
6 ST 2,5 (B.25A1.L1/67.4) B.25A1.L1 +B.Local.25 -LS B:3 BU
5 +B4I.MCC01 -X61-JB02 5 7 ST 2,5 (B.25A1.L1/67.4) B.25A1.L1 +B.Local.25 -LS B:2 WH
PE ST 2,5-PE (B.25A1.L1/67.5) +B4I.JB02 -X61 PE SH1
SH1 +B4I.JB02 -X61 PE
6 +B4I.MCC01 -X61-JB02 6 8 ST 2,5 (B.25A1.L1/67.4) B.25A1.L1 +B.Local.25 -LS B:4 BK
PE ST 2,5-PE -
9 ST 2,5 (B.25A1.P1/68.4) B.25A1.P1 +B.Local.25 -PS 1 BN
10 ST 2,5 (B.25A1.P1/68.4) B.25A1.P1 +B.Local.25 -PS 0V BU
7 +B4I.MCC01 -X61-JB02 7 11 ST 2,5 (B.25A1.P1/68.4) B.25A1.P1 +B.Local.25 -PS 2 WH
PE ST 2,5-PE -

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Hydraulic Panel Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner Junction Box Project no.: Location: +B4I.JB02
Checked: Pereira-Perez / 05.03.2020 Terminals - Terminal diagram Customer: RECYCLING-STANDARD Page: 1 / 133 97 / 133
Standard: Order: Draw. no.:
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.H|JB02|11|X71|ET-KLP.98

16:45:43
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Final date of print: 30.03.2020

Legend
+B4I.JB02-W71, Oelflex Classic 110 BK 18G1 / Ø 12.7mm

Connection input-output: Bridges:

B.25A1.V1-W71, Original Cable 3x0,75 / Ø 6.0mm

B.25A1.V1-W72, Original Cable 3x0,75 / Ø 6.0mm

B.25A1.V2-W71, Original Cable 3x0,75 / Ø 6.0mm

B.25A1.V2-W72, Original Cable 3x0,75 / Ø 6.0mm

B.25A1.V3-W71, Original Cable 3x0,75 / Ø 6.0mm

B.25A1.V3-W72, Original Cable 3x0,75 / Ø 6.0mm

B.25A1.V5-W71, Original Cable 3x0,75 / Ø 6.0mm

B.25A1.V5-W72, Original Cable 3x0,75 / Ø 6.0mm


Connection / Bridge GND Terminal Ridge bridge
Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket

Terminal strip
Manufacturer: PHOENIX CONTACT

Internal connected device +B4I.JB02-X71 External connected device


Unit / Location Device Conn. Int. Symbol Ext. Label Type Bridges Reference Unit / Location Device Conn.
1 +B4I.MCC01 -X71-JB02 1 1 ST 2,5 - B.25A1.V1 +B.Local.25 -OY-XD1 1 1
2 ST 2,5 - B.25A1.V1 +B.Local.25 -OY-XD1 2 2
PE1 ST 2,5-PE -
2 +B4I.MCC01 -X71-JB02 2 3 ST 2,5 - B.25A1.V1 +B.Local.25 -OY-XD2 1 1
4 ST 2,5 - B.25A1.V1 +B.Local.25 -OY-XD2 2 2
PE2 ST 2,5-PE -
3 +B4I.MCC01 -X71-JB02 3 5 ST 2,5 - B.25A1.V2 +B.Local.25 -OY-XD1 1 1
4 +B4I.MCC01 -X71-JB02 4 6 ST 2,5 - B.25A1.V2 +B.Local.25 -OY-XD1 2 2
PE3 ST 2,5-PE -
5 +B4I.MCC01 -X71-JB02 5 7 ST 2,5 - B.25A1.V2 +B.Local.25 -OY-XD1 1 1
8 ST 2,5 - B.25A1.V2 +B.Local.25 -OY-XD1 2 2
PE4 ST 2,5-PE -
6 +B4I.MCC01 -X71-JB02 6 9 ST 2,5 - B.25A1.V3 +B.Local.25 -OY-XD1 1 1
10 ST 2,5 - B.25A1.V3 +B.Local.25 -OY-XD1 2 2
PE5 ST 2,5-PE -
7 +B4I.MCC01 -X71-JB02 7 11 ST 2,5 - B.25A1.V3 +B.Local.25 -OY-XD1 1 1
12 ST 2,5 - B.25A1.V3 +B.Local.25 -OY-XD1 2 2
PE6 ST 2,5-PE -
8 +B4I.MCC01 -X71-JB02 8 13 ST 2,5 - B.25A1.V5 +B.Local.25 -OY-XD1 1 1
14 ST 2,5 - B.25A1.V5 +B.Local.25 -OY-XD1 2 2
PE7 ST 2,5-PE -
9 +B4I.MCC01 -X71-JB02 9 15 ST 2,5 - B.25A1.V5 +B.Local.25 -OY-XD1 1 1
16 ST 2,5 - B.25A1.V5 +B.Local.25 -OY-XD1 2 2
PE8 ST 2,5-PE -

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Hydraulic Panel Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner Junction Box Project no.: Location: +B4I.JB02
Checked: Pereira-Perez / 05.03.2020 Terminals - Terminal diagram Customer: RECYCLING-STANDARD Page: 1 / 133 98 / 133
Standard: Order: Draw. no.:
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.H|JB02|11|X71|ET-KLP.98

16:45:43
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Final date of print: 30.03.2020

Legend
+B4I.JB02-W71, Oelflex Classic 110 BK 18G1 / Ø 12.7mm

Connection input-output: Bridges:

B.25A1.V6-W71, Original Cable 3x0,75 / Ø 6.0mm

B.25A1.V6-W72, Original Cable 3x0,75 / Ø 6.0mm

B.25A1.V7-W71, Original Cable 3x0,75 / Ø 6.0mm

B.25A1.V7-W72, Original Cable 3x0,75 / Ø 6.0mm


Connection / Bridge GND Terminal Ridge bridge
Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket

Terminal strip
Manufacturer: PHOENIX CONTACT

Internal connected device +B4I.JB02-X71 External connected device


Unit / Location Device Conn. Int. Symbol Ext. Label Type Bridges Reference Unit / Location Device Conn.
10 +B4I.MCC01 -X71-JB02 10 17 ST 2,5 - B.25A1.V6 +B.Local.25 -OY-XD1 1 1
18 ST 2,5 - B.25A1.V6 +B.Local.25 -OY-XD1 2 2
PE9 ST 2,5-PE -
11 +B4I.MCC01 -X71-JB02 11 19 ST 2,5 - B.25A1.V6 +B.Local.25 -OY-XD2 1 1
20 ST 2,5 - B.25A1.V6 +B.Local.25 -OY-XD2 2 2
PE10 ST 2,5-PE -
12 +B4I.MCC01 -X71-JB02 12 21 ST 2,5 - B.25A1.V7 +B.Local.25 -OY-XD1 1 1
22 ST 2,5 - B.25A1.V7 +B.Local.25 -OY-XD1 2 2
PE11 ST 2,5-PE -
13 +B4I.MCC01 -X71-JB02 13 23 ST 2,5 - B.25A1.V7 +B.Local.25 -OY-XD2 1 1
24 ST 2,5 - B.25A1.V7 +B.Local.25 -OY-XD2 2 2
PE12 ST 2,5-PE -

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Hydraulic Panel Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner Junction Box Project no.: Location: +B4I.JB02
Checked: Pereira-Perez / 05.03.2020 Terminals - Terminal diagram Customer: RECYCLING-STANDARD Page: 2 / 133 99 / 133
Standard: Order: Draw. no.:
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.H|JB02|11|X91|ET-KLP.100

16:45:45
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Final date of print: 30.03.2020

Legend
+B4I.JB02-W91, Oelflex Classic 110 BK CY 4x1 / Ø 8mm

Connection input-output: Bridges:

B.25A1.V1-W91, Original Cable 7G0,75 / Ø 6.0mm


Connection / Bridge GND Terminal Ridge bridge
Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket

Terminal strip
Manufacturer: PHOENIX CONTACT

Internal connected device +B4I.JB02-X91 External connected device


Unit / Location Device Conn. Int. Symbol Ext. Label Type Bridges Reference Unit / Location Device Conn.
1 +B4I.MCC01 -X91 1 1 ST 2,5 (B.25A1.V1/69.6) B.25A1.V1 +B.Local.25 -OV-XD3 A 1
2 +B4I.MCC01 -X91 2 2 ST 2,5 (B.25A1.V1/69.6) B.25A1.V1 +B.Local.25 -OV-XD3 B 2
3 ST 2,5 (B.25A1.V1/69.7) B.25A1.V1 +B.Local.25 -OV-XD3 C 3
3 +B4I.MCC01 -X91 3 4 ST 2,5 (B.25A1.V1/69.7) B.25A1.V1 +B.Local.25 -OV-XD3 D 4
4 +B4I.MCC01 -X91 4 5 ST 2,5 (B.25A1.V1/69.7) B.25A1.V1 +B.Local.25 -OV-XD3 E 5
6 ST 2,5 (B.25A1.V1/69.7) B.25A1.V1 +B.Local.25 -OV-XD3 F 6

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Hydraulic Panel Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner Junction Box Project no.: Location: +B4I.JB02
Checked: Pereira-Perez / 05.03.2020 Terminals - Terminal diagram Customer: RECYCLING-STANDARD Page: 1 / 133 100 / 133
Standard: Order: Draw. no.:
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|MCC01|10|01|MC-X11|ET-KLP.101

16:45:46
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Final date of print: 30.03.2020

+B4I.MCC01-W11, Oelflex Classic 110 BK 34G1 / Ø 15.9mm


Legend
Connection input-output: Bridges:
Connection / Bridge GND Terminal Ridge bridge
Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket

Terminal strip
Manufacturer: PHOENIX CONTACT

Internal connected device +B4I.MCC01-MC-X11 External connected device


Unit / Location Device Conn. Int. Symbol Ext. Label Type Bridges Reference Unit / Location Device Conn.
+B4I.MCC01 -P1:4a P1:4a 1 ST 2,5 (B.00A01.X1/31.2) 1
+B4I.MCC01 -A01-30 1 2 ST 2,5 (B.00A01.X1/31.2) 2
+B4I.MCC01 -A01-30 2 3 ST 2,5 (B.00A01.X1/31.3) 3
+B4I.MCC01 -A01-30 3 4 ST 2,5 (B.00A01.X1/31.3) 4
+B4I.MCC01 -A01-30 4 5 ST 2,5 (B.00A01.X1/31.4) 5
+B4I.MCC01 -A01-30 5 6 ST 2,5 (B.00A01.X1/31.5) 6
+B4I.MCC01 -A01-30 6 7 ST 2,5 (B.00A01.X1/31.5) 7
B.00A01.X1 +B4I.MCC01 -KF1 11 8 ST 2,5 (B.00A01.X1/33.4) 8
B.00A01.X1 +B4I.MCC01 -KF1 14 9 ST 2,5 (B.00A01.X1/33.5) 9
B.00A01.X1 +B4I.MCC01 -KF2 14 10 ST 2,5 (B.00A01.X1/33.5) 10
B.20A1-M2 +B4I.MCC03 -TA2 19 11 ST 2,5 (B.00A01.X1/33.6) 11
B.00A01.X1 +B4I.MCC01 -KF3 14 12 ST 2,5 (B.00A01.X1/33.6) 12
B.00A01.X1 +B4I.MCC01 -KF4 14 13 ST 2,5 (B.00A01.X1/33.6) 13
B.00A01.X1 +B4I.MCC01 -KF5 14 14 ST 2,5 (B.00A01.X1/33.7) 14
15 ST 2,5 - 15
PE ST 2,5-PE (B.00A01.X1/33.7)

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 MCC Cabinet Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner Terminals Project no.: ZC133238545 Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 MCC - Terminal diagram Customer: RECYCLING-STANDARD Page: 1 / 133 101 / 133
Standard: Order: Draw. no.:
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|MCC01|10|01|X4-M|ET-KLP.102

16:45:47
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Final date of print: 30.03.2020

Legend
Connection input-output: Bridges:
Connection / Bridge GND Terminal Ridge bridge
Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket

Terminal strip
Manufacturer: PHOENIX CONTACT

Internal connected device +B4I.MCC01-X4-M External connected device


Unit / Location Device Conn. Int. Symbol Ext. Label Type Bridges Reference Unit / Location Device Conn.
1a ST 2,5-QUATTRO (19.2) +B4I.MCC01 -M:1a M:1a
1b ST 2,5-QUATTRO (19.2) +B4I.MCC01 -M:1b M:1b
1c ST 2,5-QUATTRO (19.2) +B4I.MCC01 -M:1c M:1c
1d ST 2,5-QUATTRO
(19.2) +B4I.MCC01 -M:1d M:1d
2a ST 2,5-QUATTRO (19.2) +B4I.MCC01 -M:2a M:2a
2b ST 2,5-QUATTRO (19.2) +B4I.MCC01 -M:2b M:2b
2c ST 2,5-QUATTRO (19.2) +B4I.MCC01 -M:2c M:2c
2d ST 2,5-QUATTRO
(19.2) +B4I.MCC01 -M:2d M:2d
3a ST 2,5-QUATTRO (19.2) +B4I.MCC01 -M:3a M:3a
3b ST 2,5-QUATTRO (19.2) +B4I.MCC01 -M:3b M:3b
3c ST 2,5-QUATTRO (19.2) +B4I.MCC01 -M:3c M:3c
3d ST 2,5-QUATTRO
(19.2) +B4I.MCC01 -M:3d M:3d
4a ST 2,5-QUATTRO (19.2) +B4I.MCC01 -M:4a M:4a
4b ST 2,5-QUATTRO (19.2) +B4I.MCC01 -M:4b M:4b
4c ST 2,5-QUATTRO (19.2) +B4I.MCC01 -M:4c M:4c
4d ST 2,5-QUATTRO
(19.2) +B4I.MCC01 -M:4d M:4d
5a ST 2,5-QUATTRO
(19.2) +B4I.MCC01 -M:5a M:5a
5b ST 2,5-QUATTRO (19.2) +B4I.MCC01 -M:5b M:5b
5c ST 2,5-QUATTRO (19.2) +B4I.MCC01 -M:5c M:5c
5d ST 2,5-QUATTRO
(19.2) +B4I.MCC01 -M:5d M:5d
6a ST 2,5-QUATTRO
(19.2) +B4I.MCC01 -M:6a M:6a
6b ST 2,5-QUATTRO (19.2) +B4I.MCC01 -M:6b M:6b
6c ST 2,5-QUATTRO (19.2) +B4I.MCC01 -M:6c M:6c
6d ST 2,5-QUATTRO
(19.2) +B4I.MCC01 -M:6d M:6d
7a ST 2,5-QUATTRO
(19.2) +B4I.MCC01 -M:7a M:7a
7b ST 2,5-QUATTRO (19.2) +B4I.MCC01 -M:7b M:7b
7c ST 2,5-QUATTRO (19.2) +B4I.MCC01 -M:7c M:7c
7d ST 2,5-QUATTRO (19.2) +B4I.MCC01 -M:7d M:7d
8a ST 2,5-QUATTRO
(19.2) +B4I.MCC01 -M:8a M:8a
8b ST 2,5-QUATTRO (19.2) +B4I.MCC01 -M:8b M:8b
8c ST 2,5-QUATTRO (19.2) +B4I.MCC01 -M:8c M:8c
8d ST 2,5-QUATTRO (19.2) +B4I.MCC01 -M:8d M:8d
Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 MCC Cabinet Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner Terminals Project no.: ZC133238545 Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 MCC - Terminal diagram Customer: RECYCLING-STANDARD Page: 1 / 133 102 / 133
Standard: Order: Draw. no.:
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|MCC01|10|01|X4-M|ET-KLP.102

16:45:47
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Final date of print: 30.03.2020

Legend
Connection input-output: Bridges:
Connection / Bridge GND Terminal Ridge bridge
Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket

Terminal strip
Manufacturer: PHOENIX CONTACT

Internal connected device +B4I.MCC01-X4-M External connected device


Unit / Location Device Conn. Int. Symbol Ext. Label Type Bridges Reference Unit / Location Device Conn.
9a ST 2,5-QUATTRO (19.2) +B4I.MCC01 -M:9a M:9a
9b ST 2,5-QUATTRO (19.2) +B4I.MCC01 -M:9b M:9b
9c ST 2,5-QUATTRO (19.2) +B4I.MCC01 -M:9c M:9c
9d ST 2,5-QUATTRO
(19.2) +B4I.MCC01 -M:9d M:9d
10a ST 2,5-QUATTRO (19.2) +B4I.MCC01 -M:10a M:10a
10b ST 2,5-QUATTRO (19.2) +B4I.MCC01 -M:10b M:10b
10c ST 2,5-QUATTRO (19.2) +B4I.MCC01 -M:10c M:10c
10d ST 2,5-QUATTRO
(19.2) +B4I.MCC01 -M:10d M:10d

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 MCC Cabinet Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner Terminals Project no.: ZC133238545 Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 MCC - Terminal diagram Customer: RECYCLING-STANDARD Page: 2 / 133 103 / 133
Standard: Order: Draw. no.:
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|MCC01|10|01|X4-P1|ET-KLP.104

16:45:49
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Final date of print: 30.03.2020

Legend
Connection input-output: Bridges:
Connection / Bridge GND Terminal Ridge bridge
Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket

Terminal strip
Manufacturer: PHOENIX CONTACT

Internal connected device +B4I.MCC01-X4-P1 External connected device


Unit / Location Device Conn. Int. Symbol Ext. Label Type Bridges Reference Unit / Location Device Conn.
1a ST 2,5-QUATTRO (19.3) +B4I.MCC01 -P1:1a P1:1a
1b ST 2,5-QUATTRO (19.3) +B4I.MCC01 -P1:1b P1:1b
1c ST 2,5-QUATTRO (19.3) +B4I.MCC01 -P1:1c P1:1c
1d ST 2,5-QUATTRO
(19.3) +B4I.MCC01 -P1:1d P1:1d
2a ST 2,5-QUATTRO (19.3) +B4I.MCC01 -P1:2a P1:2a
2b ST 2,5-QUATTRO (19.3) +B4I.MCC01 -P1:2b P1:2b
2c ST 2,5-QUATTRO (19.3) +B4I.MCC01 -P1:2c P1:2c
2d ST 2,5-QUATTRO
(19.3) +B4I.MCC01 -P1:2d P1:2d
3a ST 2,5-QUATTRO (19.3) +B4I.MCC01 -P1:3a P1:3a
3b ST 2,5-QUATTRO (19.3) +B4I.MCC01 -P1:3b P1:3b
3c ST 2,5-QUATTRO (19.3) +B4I.MCC01 -P1:3c P1:3c
3d ST 2,5-QUATTRO
(19.3) +B4I.MCC01 -P1:3d P1:3d
4a ST 2,5-QUATTRO (19.3) +B4I.MCC01 -P1:4a P1:4a
4b ST 2,5-QUATTRO (19.3) +B4I.MCC01 -P1:4b P1:4b
4c ST 2,5-QUATTRO (19.3) +B4I.MCC01 -P1:4c P1:4c
4d ST 2,5-QUATTRO
(19.3) +B4I.MCC01 -P1:4d P1:4d
5a ST 2,5-QUATTRO
(19.3) +B4I.MCC01 -P1:5a P1:5a
5b ST 2,5-QUATTRO (19.3) +B4I.MCC01 -P1:5b P1:5b
5c ST 2,5-QUATTRO (19.3) +B4I.MCC01 -P1:5c P1:5c
5d ST 2,5-QUATTRO
(19.3) +B4I.MCC01 -P1:5d P1:5d
6a ST 2,5-QUATTRO
(19.3) +B4I.MCC01 -P1:6a P1:6a
6b ST 2,5-QUATTRO (19.3) +B4I.MCC01 -P1:6b P1:6b
6c ST 2,5-QUATTRO (19.3) +B4I.MCC01 -P1:6c P1:6c
6d ST 2,5-QUATTRO
(19.3) +B4I.MCC01 -P1:6d P1:6d
7a ST 2,5-QUATTRO
(19.3) +B4I.MCC01 -P1:7a P1:7a
7b ST 2,5-QUATTRO (19.3) +B4I.MCC01 -P1:7b P1:7b
7c ST 2,5-QUATTRO (19.3) +B4I.MCC01 -P1:7c P1:7c
7d ST 2,5-QUATTRO (19.3) +B4I.MCC01 -P1:7d P1:7d

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 MCC Cabinet Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner Terminals Project no.: ZC133238545 Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 MCC - Terminal diagram Customer: RECYCLING-STANDARD Page: 1 / 133 104 / 133
Standard: Order: Draw. no.:
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|MCC01|10|01|X4-P2|ET-KLP.105

16:45:51
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Final date of print: 30.03.2020

Legend
Connection input-output: Bridges:
Connection / Bridge GND Terminal Ridge bridge
Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket

Terminal strip
Manufacturer: PHOENIX CONTACT

Internal connected device +B4I.MCC01-X4-P2 External connected device


Unit / Location Device Conn. Int. Symbol Ext. Label Type Bridges Reference Unit / Location Device Conn.
1a ST 2,5-QUATTRO (19.4) +B4I.MCC01 -P2:1a P2:1a
1b ST 2,5-QUATTRO (19.4) +B4I.MCC01 -P2:1b P2:1b
1c ST 2,5-QUATTRO (19.4) +B4I.MCC01 -P2:1c P2:1c
1d ST 2,5-QUATTRO
(19.4) +B4I.MCC01 -P2:1d P2:1d
2a ST 2,5-QUATTRO (19.4) +B4I.MCC01 -P2:2a P2:2a
2b ST 2,5-QUATTRO (19.4) +B4I.MCC01 -P2:2b P2:2b
2c ST 2,5-QUATTRO (19.4) +B4I.MCC01 -P2:2c P2:2c
2d ST 2,5-QUATTRO
(19.4) +B4I.MCC01 -P2:2d P2:2d
3a ST 2,5-QUATTRO (19.4) +B4I.MCC01 -P2:3a P2:3a
3b ST 2,5-QUATTRO (19.4) +B4I.MCC01 -P2:3b P2:3b
3c ST 2,5-QUATTRO (19.4) +B4I.MCC01 -P2:3c P2:3c
3d ST 2,5-QUATTRO
(19.4) +B4I.MCC01 -P2:3d P2:3d

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 MCC Cabinet Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner Terminals Project no.: ZC133238545 Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 MCC - Terminal diagram Customer: RECYCLING-STANDARD Page: 1 / 133 105 / 133
Standard: Order: Draw. no.:
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|MCC01|10|01|X4-P3|ET-KLP.106

16:45:52
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Final date of print: 30.03.2020

Legend
Connection input-output: Bridges:
Connection / Bridge GND Terminal Ridge bridge
Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket

Terminal strip
Manufacturer: PHOENIX CONTACT

Internal connected device +B4I.MCC01-X4-P3 External connected device


Unit / Location Device Conn. Int. Symbol Ext. Label Type Bridges Reference Unit / Location Device Conn.
1a ST 2,5-QUATTRO (19.5) B.00A01.X2 -FQ1 14
1b ST 2,5-QUATTRO (19.5) +B4I.MCC01 -P3:1b P3:1b
1c ST 2,5-QUATTRO (19.5) +B4I.MCC01 -P3:1c P3:1c
1d ST 2,5-QUATTRO
(19.5) +B4I.MCC01 -P3:1d P3:1d
2a ST 2,5-QUATTRO (19.5) +B4I.MCC01 -P3:2a P3:2a
2b ST 2,5-QUATTRO (19.5) +B4I.MCC01 -P3:2b P3:2b
2c ST 2,5-QUATTRO (19.5) +B4I.MCC01 -P3:2c P3:2c
2d ST 2,5-QUATTRO
(19.5) +B4I.MCC01 -P3:2d P3:2d

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 MCC Cabinet Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner Terminals Project no.: ZC133238545 Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 MCC - Terminal diagram Customer: RECYCLING-STANDARD Page: 1 / 133 106 / 133
Standard: Order: Draw. no.:
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|MCC01|10|01|X4-P4|ET-KLP.107

16:45:53
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Final date of print: 30.03.2020

Legend
Connection input-output: Bridges:
Connection / Bridge GND Terminal Ridge bridge
Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket

Terminal strip
Manufacturer: PHOENIX CONTACT

Internal connected device +B4I.MCC01-X4-P4 External connected device


Unit / Location Device Conn. Int. Symbol Ext. Label Type Bridges Reference Unit / Location Device Conn.
1a ST 2,5-QUATTRO (19.6) +B4I.MCC01 -P4:1a P4:1a
1b ST 2,5-QUATTRO (19.6) +B4I.MCC01 -P4:1b P4:1b
1c ST 2,5-QUATTRO (19.6) +B4I.MCC01 -P4:1c P4:1c
1d ST 2,5-QUATTRO
(19.6) +B4I.MCC01 -P4:1d P4:1d
2a ST 2,5-QUATTRO (19.6) +B4I.MCC01 -P4:2a P4:2a
2b ST 2,5-QUATTRO (19.6) +B4I.MCC01 -P4:2b P4:2b
2c ST 2,5-QUATTRO (19.6) +B4I.MCC01 -P4:2c P4:2c
2d ST 2,5-QUATTRO
(19.6) +B4I.MCC01 -P4:2d P4:2d
3a ST 2,5-QUATTRO (19.6) +B4I.MCC01 -P4:3a P4:3a
3b ST 2,5-QUATTRO (19.6) +B4I.MCC01 -P4:3b P4:3b
3c ST 2,5-QUATTRO (19.6) +B4I.MCC01 -P4:3c P4:3c
3d ST 2,5-QUATTRO
(19.6) +B4I.MCC01 -P4:3d P4:3d

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 MCC Cabinet Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner Terminals Project no.: ZC133238545 Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 MCC - Terminal diagram Customer: RECYCLING-STANDARD Page: 1 / 133 107 / 133
Standard: Order: Draw. no.:
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|MCC01|10|01|X4-P5|ET-KLP.108

16:45:53
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Final date of print: 30.03.2020

Legend
Connection input-output: Bridges:
Connection / Bridge GND Terminal Ridge bridge
Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket

Terminal strip
Manufacturer: PHOENIX CONTACT

Internal connected device +B4I.MCC01-X4-P5 External connected device


Unit / Location Device Conn. Int. Symbol Ext. Label Type Bridges Reference Unit / Location Device Conn.
1a ST 2,5-QUATTRO -
1b ST 2,5-QUATTRO -
1c ST 2,5-QUATTRO -
1d ST 2,5-QUATTRO
-
2a ST 2,5-QUATTRO -
2b ST 2,5-QUATTRO -
2c ST 2,5-QUATTRO -
2d ST 2,5-QUATTRO
-
3a ST 2,5-QUATTRO -
3b ST 2,5-QUATTRO -
3c ST 2,5-QUATTRO -
3d ST 2,5-QUATTRO
-

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 MCC Cabinet Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner Terminals Project no.: ZC133238545 Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 MCC - Terminal diagram Customer: RECYCLING-STANDARD Page: 1 / 133 108 / 133
Standard: Order: Draw. no.:
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|MCC01|10|02|X41-CP01|ET-KLP.109

16:45:54
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Final date of print: 30.03.2020

Legend

+B4I.CB01-W41, Oelflex Classic 110 BK 3G1 / Ø 6.0mm


Connection input-output: Bridges:
Connection / Bridge GND Terminal Ridge bridge
Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket

Terminal strip
Manufacturer: PHOENIX CONTACT

Internal connected device +B4I.MCC01-X41-CP01 External connected device


Unit / Location Device Conn. Int. Symbol Ext. Label Type Bridges Reference Unit / Location Device Conn.
+B4I.MCC01 -P2:2a P2:2a 1 ST 2,5 (B4I.CB016/24.2) +B4I.CB01 -X41 1 1
+B4I.MCC01 -M:8a M:8a 2 ST 2,5 (B4I.CB016/24.2) +B4I.CB01 -X41 2 2

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 MCC Cabinet Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner Terminals Project no.: ZC133238545 Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 CP01 - Terminal diagram Customer: RECYCLING-STANDARD Page: 1 / 133 109 / 133
Standard: Order: Draw. no.:
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|MCC01|10|01|X10|ET-KLP.110

16:45:55
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Final date of print: 30.03.2020

Legend

B.00A02.H1-W61, Oelflex Classic 110 BK 5G1 / Ø 7.1mm

B.00A02.H1-W62, Oelflex Classic 110 BK 5G1 / Ø 7.1mm


Connection input-output: Bridges:
Connection / Bridge GND Terminal Ridge bridge
Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket

Terminal strip
Manufacturer: PHOENIX CONTACT

Internal connected device +B4I.MCC01-X10 External connected device


Unit / Location Device Conn. Int. Symbol Ext. Label Type Bridges Reference Unit / Location Device Conn.
+B4I.MCC01 -A01-10 1 1 ST 2,5 (B.00A02.H1B4I.CB01/23.1)

+B4I.MCC01 -A01-10 5 2 ST 2,5 (B.00A02.H1B4I.CB01/23.1)

3 ST 2,5 (B.00A02.H1B4I.CB01/23.2) +B4I.CB02 -X10 1 1


4 ST 2,5 (B.00A02.H1B4I.CB01/23.2) +B4I.CB02 -X10 2 2
5 ST 2,5 (B.00A02.H1B4I.CB01/23.2) +B4I.CB02 -X10 3 3
6 ST 2,5 (B.00A02.H1B4I.CB01/23.2) +B4I.CB02 -X10 4 4
7 ST 2,5 (B.00A02.H1B4I.CB01/23.3) +B4I.CB01 -X10 1 1
8 ST 2,5 (B.00A02.H1B4I.CB01/23.3) +B4I.CB01 -X10 2 2
9 ST 2,5 (B.00A02.H1B4I.CB01/23.4) +B4I.CB01 -X10 3 3
10 ST 2,5 (B.00A02.H1B4I.CB01/23.4) +B4I.CB01 -X10 4 4
11 ST 2,5 (B.00A02.H1B4I.CB01/23.4) +B4I.MCC01 -X10 13
12 ST 2,5 (B.00A02.H1B4I.CB01/23.5) +B4I.MCC01 -X10 14
13 ST 2,5 (B.00A02.H1B4I.CB01/23.5) +B4I.MCC01 -X10 11
14 ST 2,5 (B.00A02.H1B4I.CB01/23.5) +B4I.MCC01 -X10 12
15 ST 2,5 (B.00A02.H1B4I.CB01/23.6) B.00A02.H1 +B4I.MCC01 -S3 11
16 ST 2,5 (B.00A02.H1B4I.CB01/23.6) B.00A02.H1 +B4I.MCC01 -S3 21
17 ST 2,5 (B.00A02.H1B4I.CB01/23.6) B.00A02.H1 +B4I.MCC01 -S3 12
18 ST 2,5 (B.00A02.H1B4I.CB01/23.7) B.00A02.H1 +B4I.MCC01 -S3 22
+B4I.MCC01 -A01-10 13 19 ST 2,5 (B.00A02.H1B4I.CB01/23.7)

+B4I.MCC01 -A01-10 9 20 ST 2,5 (B.00A02.H1B4I.CB01/23.7)

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 MCC Cabinet Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner Terminals Project no.: ZC133238545 Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 MCC - Terminal diagram Customer: RECYCLING-STANDARD Page: 1 / 133 110 / 133
Standard: Order: Draw. no.:
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|MCC01|10|01|X11|ET-KLP.111

16:45:56
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Final date of print: 30.03.2020

B.20A1-M1-W111, Oelflex Classic 110 BK CY 2x1 / Ø 7.4mm

B.20A1-M2-W111, Oelflex Classic 110 BK CY 2x1 / Ø 7.4mm


Legend
Connection input-output: Bridges:
Connection / Bridge GND Terminal Ridge bridge
Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket

Terminal strip
Manufacturer: PHOENIX CONTACT

Internal connected device +B4I.MCC01-X11 External connected device


Unit / Location Device Conn. Int. Symbol Ext. Label Type Bridges Reference Unit / Location Device Conn.
B.20A1-M1 +B4I.MCC03 -TA1 XAO:2 1 ST 2,5 (B.20A1-M1B.Local.20/40.3) B.20A1 +B.Local.20 -M1 1 1
B.20A1-M1 +B4I.MCC03 -TA1 XAO:1 2 ST 2,5 (B.20A1-M1B.Local.20/40.3) B.20A1 +B.Local.20 -M1 2 2
B.20A1-M2 +B4I.MCC03 -TA2 XAO:2 3 ST 2,5 (B.20A1-M2B.Local.20/41.3) B.20A1 +B.Local.20 -M2 1 1
B.20A1-M2 +B4I.MCC03 -TA2 XAO:1 4 ST 2,5 (B.20A1-M2B.Local.20/41.3) B.20A1 +B.Local.20 -M2 2 2

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 MCC Cabinet Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner Terminals Project no.: ZC133238545 Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 MCC - Terminal diagram Customer: RECYCLING-STANDARD Page: 1 / 133 111 / 133
Standard: Order: Draw. no.:
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|MCC01|10|01|X0|ET-KLP.112

16:45:57
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Final date of print: 30.03.2020
+B4I.MCC01-W20, Oelflex Classic 110 BK 5G2,5 / Ø 10mm

Legend
Connection input-output: Bridges:
Connection / Bridge GND Terminal Ridge bridge
Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket

Terminal strip
Manufacturer: PHOENIX CONTACT

Internal connected device +B4I.MCC01-X0 External connected device


Unit / Location Device Conn. Int. Symbol Ext. Label Type Bridges Reference Unit / Location Device Conn.
1 +B4I.MCC02 -SF1 2 1 ST 2,5 (B4I.MCC02/17.3)
2 +B4I.MCC02 -SF1 4 2 ST 2,5 (B4I.MCC02/17.3)
PE ST 2,5-PE -
3 +B4I.MCC02 -SF1 6 3 ST 2,5 (B4I.MCC02/17.3)
4 +B4I.MCC02 -SF1 N 4 ST 2,5 (B4I.MCC02/17.3)

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 MCC Cabinet Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner Terminals Project no.: ZC133238545 Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 MCC - Terminal diagram Customer: RECYCLING-STANDARD Page: 1 / 133 112 / 133
Standard: Order: Draw. no.:
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|MCC01|10|01|X21|ET-KLP.113

16:45:57
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Final date of print: 30.03.2020

Legend

+B4I.JB02-W21, Oelflex Classic 110 BK 3G2,5 / Ø 8.1mm


Connection input-output: Bridges:
Connection / Bridge GND Terminal Ridge bridge
Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket

Terminal strip
Manufacturer: PHOENIX CONTACT

Internal connected device +B4I.MCC01-X21 External connected device


Unit / Location Device Conn. Int. Symbol Ext. Label Type Bridges Reference Unit / Location Device Conn.
+B4I.MCC01 -FC14 2 1 ST 2,5 (20.6) +B4I.JB02 -X21 1 1
+B4I.MCC01 -FC14 N 2 ST 2,5 (20.6) +B4I.JB02 -X21 2 2
PE ST 2,5-PE (20.6) +B4I.JB02 -X21 PE GNYE

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 MCC Cabinet Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner Terminals Project no.: ZC133238545 Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 MCC - Terminal diagram Customer: RECYCLING-STANDARD Page: 1 / 133 113 / 133
Standard: Order: Draw. no.:
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|MCC01|10|06|X21-JB05|ET-KLP.114

16:45:58
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Final date of print: 30.03.2020

Legend

+B4I.JB05-W11, Oelflex Classic 110 BK 3G2,5 / Ø 6.0mm


Connection input-output: Bridges:
Connection / Bridge GND Terminal Ridge bridge
Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket

Terminal strip
Manufacturer: PHOENIX CONTACT

Internal connected device +B4I.MCC01-X21-JB05 External connected device


Unit / Location Device Conn. Int. Symbol Ext. Label Type Bridges Reference Unit / Location Device Conn.
+B4I.MCC01 -FC15 2 1 ST 2,5 (20.7) +B4I.JB05 -X21 1 1
+B4I.MCC01 -FC15 N 2 ST 2,5 (20.7) +B4I.JB05 -X21 2 2
PE ST 2,5-PE (20.7) +B4I.JB05 -X21 3 GNYE

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 MCC Cabinet Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner Terminals Project no.: ZC133238545 Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 JB05 - Terminal diagram Customer: RECYCLING-STANDARD Page: 1 / 133 114 / 133
Standard: Order: Draw. no.:
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|MCC01|10|02|X61-CP01|ET-KLP.115

16:45:59
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Final date of print: 30.03.2020

Legend

+B4I.CB01-W12, Oelflex Classic 110 BK 34G1 / Ø 15.9mm


Connection input-output: Bridges:
Connection / Bridge GND Terminal Ridge bridge
Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket

Terminal strip
Manufacturer: PHOENIX CONTACT

Internal connected device +B4I.MCC01-X61-CP01 External connected device


Unit / Location Device Conn. Int. Symbol Ext. Label Type Bridges Reference Unit / Location Device Conn.
+B4I.MCC01 -P1:4b P1:4b 1 ST 2,5 (B.00A02.H2B4I.CB01/34.3) +B4I.CB01 -X61 1 1
+B4I.MCC01 -A01-31 1 2 ST 2,5 (B.00A02.H2B4I.CB01/34.3) +B4I.CB01 -X61 2 2
+B4I.MCC01 -A01-31 2 3 ST 2,5 (B.00A02.H2B4I.CB01/34.4) +B4I.CB01 -X61 3 3
+B4I.MCC01 -M:5b M:5b 4 ST 2,5 (B.00A02.H2B4I.CB01/34.5) +B4I.CB01 -X61 4 4
+B4I.MCC01 -A01-40 6 5 ST 2,5 (B.00A02.H2B4I.CB01/34.5) +B4I.CB01 -X61 5 5
+B4I.MCC01 -A01-31 3 6 ST 2,5 (B.00A02.H3B4I.CB01/35.3) +B4I.CB01 -X61 6 6
+B4I.MCC01 -A01-40 7 7 ST 2,5 (B.00A02.H3B4I.CB01/35.5) +B4I.CB01 -X61 7 7
+B4I.MCC01 -A01-31 4 8 ST 2,5 (B.00A02.H4B4I.CB01/36.3) +B4I.CB01 -X61 8 8
+B4I.MCC01 -A01-31 5 9 ST 2,5 (B.00A02.H4B4I.CB01/36.4) +B4I.CB01 -X61 9 9
+B4I.MCC01 -A01-30 8 10 ST 2,5 (B.00A02.H4B4I.CB01/36.5) +B4I.CB01 -X61 10 10
+B4I.MCC01 -A01-31 7 11 ST 2,5 (B.00A02.H6B4I.CB01/37.3) +B4I.CB01 -X61 11 11
+B4I.MCC01 -A01-31 6 12 ST 2,5 (B.00A02.H6B4I.CB01/37.4) +B4I.CB01 -X61 12 12
+B4I.MCC01 -A01-32 7 13 ST 2,5 (B.20A1.H2B4I.CB01/44.4) +B4I.CB01 -X61 13 13
+B4I.MCC01 -A01-32 6 14 ST 2,5 (B.20A1.H2B4I.CB01/44.5) +B4I.CB01 -X61 14 14
+B4I.MCC01 -A01-33 3 15 ST 2,5 (B.20A2.H1B4I.CB01/54.3) +B4I.CB01 -X61 15 15
+B4I.MCC01 -A01-33 2 16 ST 2,5 (B.20A2.H1B4I.CB01/54.4) +B4I.CB01 -X61 16 16
+B4I.MCC01 -A01-34 3 17 ST 2,5 (B.20A3.H1B4I.CB01/59.3) +B4I.CB01 -X61 17 17
+B4I.MCC01 -A01-34 4 18 ST 2,5 (B.20A3.H1B4I.CB01/59.4) +B4I.CB01 -X61 18 18
+B4I.MCC01 -A01-41 4 19 ST 2,5 (B.00A02.X12B4I.LCP01/32.3) +B4I.CB01 -X61 19 19
+B4I.MCC01 -A01-41 5 20 ST 2,5 (B.00A02.X12B4I.LCP01/32.4) +B4I.CB01 -X61 20 20
+B4I.MCC01 -A01-41 6 21 ST 2,5 (B.00A02.X12B4I.LCP01/32.5) +B4I.CB01 -X61 21 21
+B4I.MCC01 -A01-11 3 22 ST 2,5 (B.00A02.H7/30.3) +B4I.CB01 -X61 22 22
+B4I.MCC01 -A01-11 7 23 ST 2,5 (B.00A02.H7/30.3) +B4I.CB01 -X61 23 23
+B4I.MCC01 -A01-11 11 24 ST 2,5 (B.00A02.H7/30.4) +B4I.CB01 -X61 24 24
+B4I.MCC01 -A01-11 15 25 ST 2,5 (B.00A02.H7/30.4) +B4I.CB01 -X61 25 25
PE ST 2,5-PE -

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 MCC Cabinet Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner Terminals Project no.: ZC133238545 Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 CP01 - Terminal diagram Customer: RECYCLING-STANDARD Page: 1 / 133 115 / 133
Standard: Order: Draw. no.:
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|MCC01|10|03|X61-CP02|ET-KLP.116

16:46:00
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Final date of print: 30.03.2020

Legend

+B4I.CB02-W61, Oelflex Classic 110 BK 12G1 / Ø 10.5mm


Connection input-output: Bridges:
Connection / Bridge GND Terminal Ridge bridge
Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket

Terminal strip
Manufacturer: PHOENIX CONTACT

Internal connected device +B4I.MCC01-X61-CP02 External connected device


Unit / Location Device Conn. Int. Symbol Ext. Label Type Bridges Reference Unit / Location Device Conn.
+B4I.MCC01 -P1:6a P1:6a 1 ST 2,5 (B.20A4.H1B4I.CB02/63.3) +B4I.CB02 -X61 1 1
+B4I.MCC01 -P1:6d P1:6d
+B4I.MCC01 -A01-34 6 2 ST 2,5 (B.20A4.H1B4I.CB02/63.3) +B4I.CB02 -X61 2 2
+B4I.MCC01 -A01-34 5 3 ST 2,5 (B.20A4.H1B4I.CB02/63.4) +B4I.CB02 -X61 3 3
+B4I.MCC01 -A01-34 7 4 ST 2,5 (B.20A5.H1B4I.CB02/65.3) +B4I.CB02 -X61 4 4
+B4I.MCC01 -A01-34 8 5 ST 2,5 (B.20A5.H1B4I.CB02/65.4) +B4I.CB02 -X61 5 5
+B4I.MCC01 -A01-11 1 6 ST 2,5 (B.20A1.H3B4I.CB02/45.4) +B4I.CB02 -X61 6 6
+B4I.MCC01 -A01-11 5 7 ST 2,5 (B.20A1.H3B4I.CB02/45.5) +B4I.CB02 -X61 7 7
+B4I.MCC01 -A01-11 6 8 ST 2,5 (B.20A1.H3B4I.CB02/45.5) +B4I.CB02 -X61 8 8
+B4I.MCC01 -A01-36 5 9 ST 2,5 (B.20A2.H2B4I.CB02/55.3) +B4I.CB02 -X61 9 9
+B4I.MCC01 -A01-36 6 10 ST 2,5 (B.20A2.H2B4I.CB02/55.4) +B4I.CB02 -X61 10 10
PE ST 2,5-PE -

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 MCC Cabinet Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner Terminals Project no.: ZC133238545 Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 CP02 - Terminal diagram Customer: RECYCLING-STANDARD Page: 1 / 133 116 / 133
Standard: Order: Draw. no.:
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|MCC01|10|04|X61-JB01|ET-KLP.117

16:46:01
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Final date of print: 30.03.2020

Legend

+B4I.JB01-W61, Oelflex Classic 110 BK 34G1 / Ø 15.9mm


Connection input-output: Bridges:
Connection / Bridge GND Terminal Ridge bridge
Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket

Terminal strip
Manufacturer: PHOENIX CONTACT

Internal connected device +B4I.MCC01-X61-JB01 External connected device


Unit / Location Device Conn. Int. Symbol Ext. Label Type Bridges Reference Unit / Location Device Conn.
+B4I.MCC01 -P1:4d P1:4d 1 ST 2,5 (B.20A2.G1/52.4) +B4I.JB01 -X61 1 1
+B4I.MCC01 -M:4c M:4c 2 ST 2,5 (B.20A2.G1/52.4) +B4I.JB01 -X61 2 2
+B4I.MCC01 -A01-32 1 3 ST 2,5 (B.20A2.G1/52.4) +B4I.JB01 -X61 3 3
+B4I.MCC01 -A01-32 2 4 ST 2,5 (B.20A2.G2/53.4) +B4I.JB01 -X61 6 4
+B4I.MCC01 -A01-10 10 5 ST 2,5 (B.20A3.G1/56.4) +B4I.JB01 -X61 9 5
+B4I.MCC01 -A01-10 14 6 ST 2,5 (B.20A3.G1/56.4) +B4I.JB01 -X61 10 6
+B4I.MCC01 -A01-10 2 7 ST 2,5 (B.20A3.G1/56.4) +B4I.JB01 -X61 11 7
+B4I.MCC01 -A01-10 6 8 ST 2,5 (B.20A3.G1/56.4) +B4I.JB01 -X61 12 8
+B4I.MCC01 -P1:5d P1:5d 9 ST 2,5 (B.20A3.G2/57.4) +B4I.JB01 -X61 13 9
+B4I.MCC01 -M:6d M:6d 10 ST 2,5 (B.20A3.G2/57.4) +B4I.JB01 -X61 14 10
+B4I.MCC01 -A01-32 5 11 ST 2,5 (B.20A3.G2/57.4) +B4I.JB01 -X61 15 11
+B4I.MCC01 -A01-33 4 12 ST 2,5 (B.20A3.G3/58.4) +B4I.JB01 -X61 18 12
13 ST 2,5 -
+B4I.MCC01 -A01-34 2 14 ST 2,5 (B.20A4.G2/61.3) +B4I.JB01 -X61 24 14
+B4I.MCC01 -A01-36 2 15 ST 2,5 (B.20A4.G2/61.5) +B4I.JB01 -X61 27 15
+B4I.MCC01 -A01-33 8 16 ST 2,5 (B.20A4.G3/62.3) +B4I.JB01 -X61 30 16
+B4I.MCC01 -A01-36 1 17 ST 2,5 (B.20A4.G3/62.5) +B4I.JB01 -X61 33 17
+B4I.MCC01 -A01-10 11 18 ST 2,5 (B.20A5.G1/64.4) +B4I.JB01 -X61 36 18
+B4I.MCC01 -A01-10 15 19 ST 2,5 (B.20A5.G1/64.4) +B4I.JB01 -X61 37 19
+B4I.MCC01 -A01-10 3 20 ST 2,5 (B.20A5.G1/64.4) +B4I.JB01 -X61 38 20
+B4I.MCC01 -A01-10 7 21 ST 2,5 (B.20A5.G1/64.4) +B4I.JB01 -X61 39 21
B.20A6.X1 +B4I.MCC01 -QA1 2 22 ST 2,5 (B.20A6.X1/66.3) +B4I.JB01 -X61 40 22
B.20A6.X1 +B4I.MCC01 -QA1 4 23 ST 2,5 (B.20A6.X1/66.3) +B4I.JB01 -X61 41 23
+B4I.MCC01 -P1:7a P1:7a 24 ST 2,5 (B.20A6.X1/66.4) +B4I.JB01 -X61 42 24
+B4I.MCC01 -A01-32 4 25 ST 2,5 (B.20A6.X1/66.4) +B4I.JB01 -X61 43 25
+B4I.MCC01 -A01-32 3 26 ST 2,5 (B.20A6.X1/66.4) +B4I.JB01 -X61 44 26
PE ST 2,5-PE -

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 MCC Cabinet Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner Terminals Project no.: ZC133238545 Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 JB01 - Terminal diagram Customer: RECYCLING-STANDARD Page: 1 / 133 117 / 133
Standard: Order: Draw. no.:
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|MCC01|10|05|X61-JB02|ET-KLP.118

16:46:03
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Final date of print: 30.03.2020

Legend

+B4I.JB02-W61, Oelflex Classic 110 BK 18G1 / Ø 12.7mm


Connection input-output: Bridges:
Connection / Bridge GND Terminal Ridge bridge
Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket

Terminal strip
Manufacturer: PHOENIX CONTACT

Internal connected device +B4I.MCC01-X61-JB02 External connected device


Unit / Location Device Conn. Int. Symbol Ext. Label Type Bridges Reference Unit / Location Device Conn.
+B4I.MCC01 -P1:3d P1:3d 1 ST 2,5 (B.25A1.L1/67.3) +B4I.JB02 -X61 1 1
+B4I.MCC01 -P4:1b P4:1b
+B4I.MCC01 -M:6a M:6a 2 ST 2,5 (B.25A1.L1/67.3) +B4I.JB02 -X61 2 2
+B4I.MCC01 -M:7a M:7a
+B4I.MCC01 -A01-35 1 3 ST 2,5 (B.25A1.L1/67.3) +B4I.JB02 -X61 3 3
+B4I.MCC01 -A01-35 2 4 ST 2,5 (B.25A1.L1/67.4) +B4I.JB02 -X61 4 4
+B4I.MCC01 -A01-35 3 5 ST 2,5 (B.25A1.L1/67.5) +B4I.JB02 -X61 7 5
+B4I.MCC01 -A01-35 4 6 ST 2,5 (B.25A1.L1/67.5) +B4I.JB02 -X61 8 6
+B4I.MCC01 -A01-33 5 7 ST 2,5 (B.25A1.P1/68.4) +B4I.JB02 -X61 11 7
PE ST 2,5-PE -

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 MCC Cabinet Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner Terminals Project no.: ZC133238545 Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 JB02 - Terminal diagram Customer: RECYCLING-STANDARD Page: 1 / 133 118 / 133
Standard: Order: Draw. no.:
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|MCC01|10|06|X61-JB05|ET-KLP.119

16:46:04
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Final date of print: 30.03.2020

Legend

+B4I.JB05-W12, Oelflex Classic 110 BK 5G1 / Ø 7.1mm


Connection input-output: Bridges:
Connection / Bridge GND Terminal Ridge bridge
Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket

Terminal strip
Manufacturer: PHOENIX CONTACT

Internal connected device +B4I.MCC01-X61-JB05 External connected device


Unit / Location Device Conn. Int. Symbol Ext. Label Type Bridges Reference Unit / Location Device Conn.
+B4I.MCC01 -P2:1d P2:1d 1 ST 2,5 (B.20A1.G1B4I.JB05/42.4) +B4I.JB05 -X61 2 1
+B4I.MCC01 -A01-36 3 2 ST 2,5 (B.20A1.G1B4I.JB05/42.4) +B4I.JB05 -X61 3 2
PE ST 2,5-PE -
+B4I.MCC01 -A01-36 4 3 ST 2,5 (B.20A1.G2B4I.JB05/43.4) +B4I.JB05 -X61 6 3

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 MCC Cabinet Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner Terminals Project no.: ZC133238545 Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 JB05 - Terminal diagram Customer: RECYCLING-STANDARD Page: 1 / 133 119 / 133
Standard: Order: Draw. no.:
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|MCC01|10|04|X62-JB01|ET-KLP.120

16:46:04
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Final date of print: 30.03.2020

Legend

+B4I.JB01-W62, Oelflex Classic 110 BK 12G1 / Ø 16.9mm


Connection input-output: Bridges:
Connection / Bridge GND Terminal Ridge bridge
Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket

Terminal strip
Manufacturer: PHOENIX CONTACT

Internal connected device +B4I.MCC01-X62-JB01 External connected device


Unit / Location Device Conn. Int. Symbol Ext. Label Type Bridges Reference Unit / Location Device Conn.
+B4I.MCC01 -P1:5c P1:5c 1 ST 2,5 (B.10B1.L1/39.4) +B4I.JB01 -X61 50 1
+B4I.MCC01 -X62-JB01 3
+B4I.MCC01 -M:6b M:6b 2 ST 2,5 (B.10B1.L1/39.4) +B4I.JB01 -X61 51 2
+B4I.MCC01 -M:6d M:6d
+B4I.MCC01 -X62-JB01 1 3 ST 2,5 (B.10B1.L1/39.4) +B4I.JB01 -X61 52 3
+B4I.MCC01 -A01-31 8 4 ST 2,5 (B.10B1.L1/39.4) +B4I.JB01 -X61 53 4
5 ST 2,5 -
+B4I.MCC01 -A01-10 12 6 ST 2,5 (B.20A4.G1/60.4) +B4I.JB01 -X61 21 6
+B4I.MCC01 -A01-34 1 7 ST 2,5 (B.30H1.S1/80.4) +B4I.JB01 -X61 47 7
8 ST 2,5 - +B4I.JB01 -X61 49 8
+B4I.MCC01 -A01-10 16 9 ST 2,5 (B.20A4.G1/60.4) +B4I.JB01 -X61 54 9
+B4I.MCC01 -A01-10 4 10 ST 2,5 (B.20A4.G1/60.4) +B4I.JB01 -X61 55 10
+B4I.MCC01 -A01-10 8 11 ST 2,5 (B.20A4.G1/60.4) +B4I.JB01 -X61 56 11
PE ST 2,5-PE - +B4I.JB01 -X61 PE

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 MCC Cabinet Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner Terminals Project no.: ZC133238545 Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 JB01 - Terminal diagram Customer: RECYCLING-STANDARD Page: 1 / 133 120 / 133
Standard: Order: Draw. no.:
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|MCC01|10|04|X63-JB01|ET-KLP.121

16:46:05
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Final date of print: 30.03.2020

Legend
Connection input-output: Bridges:
Connection / Bridge GND Terminal Ridge bridge
Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket

Terminal strip
Manufacturer: PHOENIX CONTACT

Internal connected device +B4I.MCC01-X63-JB01 External connected device


Unit / Location Device Conn. Int. Symbol Ext. Label Type Bridges Reference Unit / Location Device Conn.
1 ST 2,5 -
2 ST 2,5 -
3 ST 2,5 -
4 ST 2,5 -
PE ST 2,5-PE -

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 MCC Cabinet Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner Terminals Project no.: ZC133238545 Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 JB01 - Terminal diagram Customer: RECYCLING-STANDARD Page: 1 / 133 121 / 133
Standard: Order: Draw. no.:
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|MCC01|10|01|X70|ET-KLP.122

16:46:06
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Final date of print: 30.03.2020

Legend

B.00A02.X11-W71, Oelflex Classic 110 BK 3G1 / Ø 6.0mm


Connection input-output: Bridges:
Connection / Bridge GND Terminal Ridge bridge
Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket

Terminal strip
Manufacturer: PHOENIX CONTACT

Internal connected device +B4I.MCC01-X70 External connected device


Unit / Location Device Conn. Int. Symbol Ext. Label Type Bridges Reference Unit / Location Device Conn.
B.00A02.X11 +B4I.MCC01 -KF1 14 1 ST 2,5 (B.00A02.X11/38.5) B.00A02.X11 +B.Local.00 -H1 1 1
+B4I.MCC01 -M:8b M:8b 2 ST 2,5 (B.00A02.X11/38.5) B.00A02.X11 +B.Local.00 -H1 2 2

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 MCC Cabinet Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner Terminals Project no.: ZC133238545 Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 MCC - Terminal diagram Customer: RECYCLING-STANDARD Page: 1 / 133 122 / 133
Standard: Order: Draw. no.:
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|MCC01|10|05|X71-JB02|ET-KLP.123

16:46:06
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Final date of print: 30.03.2020

Legend

+B4I.JB02-W71, Oelflex Classic 110 BK 18G1 / Ø 12.7mm


Connection input-output: Bridges:
Connection / Bridge GND Terminal Ridge bridge
Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket

Terminal strip
Manufacturer: PHOENIX CONTACT

Internal connected device +B4I.MCC01-X71-JB02 External connected device


Unit / Location Device Conn. Int. Symbol Ext. Label Type Bridges Reference Unit / Location Device Conn.
B.25A1.V1 +B4I.MCC01 -KF1 2 1 ST 2,5 (B.25A1.V1/69.4) +B4I.JB02 -X71 1 1
B.25A1.V1 +B4I.MCC01 -KF2 2 2 ST 2,5 (B.25A1.V1/69.5) +B4I.JB02 -X71 3 2
+B4I.MCC01 -A01-50 3 3 ST 2,5 (B.25A1.V2/70.3) +B4I.JB02 -X71 5 3
4 ST 2,5 (B.25A1.V2/70.3) +B4I.JB02 -X71 6 4
+B4I.MCC01 -M:3c M:3c
+B4I.MCC01 -A01-50 2 5 ST 2,5 (B.25A1.V2/70.4) +B4I.JB02 -X71 7 5
+B4I.MCC01 -A01-51 1 6 ST 2,5 (B.25A1.V3/71.3) +B4I.JB02 -X71 9 6
+B4I.MCC01 -A01-50 8 7 ST 2,5 (B.25A1.V3/71.4) +B4I.JB02 -X71 11 7
+B4I.MCC01 -A01-51 3 8 ST 2,5 (B.25A1.V5/72.3) +B4I.JB02 -X71 13 8
+B4I.MCC01 -A01-51 8 9 ST 2,5 (B.25A1.V5/72.4) +B4I.JB02 -X71 15 9
+B4I.MCC01 -A01-51 2 10 ST 2,5 (B.25A1.V6/73.3) +B4I.JB02 -X71 17 10
+B4I.MCC01 -A01-50 5 11 ST 2,5 (B.25A1.V6/73.4) +B4I.JB02 -X71 19 11
+B4I.MCC01 -A01-52 3 12 ST 2,5 (B.25A1.V7/75.3) +B4I.JB02 -X71 21 12
+B4I.MCC01 -A01-52 8 13 ST 2,5 (B.25A1.V7/75.4) +B4I.JB02 -X71 23 13
+B4I.MCC01 -P3:2a P3:2a
+B4I.MCC01 -A01-52 1 14 ST 2,5 (B.25A1.V1/69.2) +B4I.MCC01 -P3:2a P3:2a
+B4I.MCC01 -A01-52 2 15 ST 2,5 (B.25A1.V1/69.3)
PE ST 2,5-PE -

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 MCC Cabinet Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner Terminals Project no.: ZC133238545 Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 JB02 - Terminal diagram Customer: RECYCLING-STANDARD Page: 1 / 133 123 / 133
Standard: Order: Draw. no.:
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|MCC01|10|03|X71-CP02|ET-KLP.124

16:46:08
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Final date of print: 30.03.2020

Legend

+B4I.CB02-W62, Oelflex Classic 110 BK 4G1 / Ø 7.2mm


Connection input-output: Bridges:
Connection / Bridge GND Terminal Ridge bridge
Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket

Terminal strip
Manufacturer: PHOENIX CONTACT

Internal connected device +B4I.MCC01-X71-CP02 External connected device


Unit / Location Device Conn. Int. Symbol Ext. Label Type Bridges Reference Unit / Location Device Conn.
+B4I.MCC01 -A01-40 8 1 ST 2,5 (B.20A4.G3/62.7) +B4I.CB02 -X71 1 1
+B4I.MCC01 -M:10b M:10b 2 ST 2,5 (B.20A4.G3/62.7) +B4I.CB02 -X71 2 2

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 MCC Cabinet Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner Terminals Project no.: ZC133238545 Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 CP02 - Terminal diagram Customer: RECYCLING-STANDARD Page: 1 / 133 124 / 133
Standard: Order: Draw. no.:
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|MCC01|10|05|X72-JB02|ET-KLP.125

16:46:08
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Final date of print: 30.03.2020

Legend
Connection input-output: Bridges:
Connection / Bridge GND Terminal Ridge bridge
Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket

Terminal strip
Manufacturer: PHOENIX CONTACT

Internal connected device +B4I.MCC01-X72-JB02 External connected device


Unit / Location Device Conn. Int. Symbol Ext. Label Type Bridges Reference Unit / Location Device Conn.
1 ST 2,5 -
2 ST 2,5 -
3 ST 2,5 -
4 ST 2,5 -

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 MCC Cabinet Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner Terminals Project no.: ZC133238545 Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 JB02 - Terminal diagram Customer: RECYCLING-STANDARD Page: 1 / 133 125 / 133
Standard: Order: Draw. no.:
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|MCC01|10|04|X81-JB01|ET-KLP.126

16:46:09
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Final date of print: 30.03.2020

+B4I.JB01-W81, Oelflex Classic 110 BK CY 4x0,75 / Ø 8mm


Legend

B.20A1.T2-W81, Oelflex Classic 110 BK CY 2x1 / Ø 7.4mm

B.20A1.T1-W81, Oelflex Classic 110 BK CY 2x1 / Ø 7.4mm


Connection input-output: Bridges:
Connection / Bridge GND Terminal Ridge bridge
Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket

Terminal strip
Manufacturer: PHOENIX CONTACT

Internal connected device +B4I.MCC01-X81-JB01 External connected device


Unit / Location Device Conn. Int. Symbol Ext. Label Type Bridges Reference Unit / Location Device Conn.
+B4I.MCC01 -P1:3c P1:3c 1 ST 2,5 (B.20A1.S1/46.4) +B4I.JB01 -X81 1 1
+B4I.MCC01 -M:3a M:3a 2 ST 2,5 (B.20A1.S1/46.4) +B4I.JB01 -X81 2 2
+B4I.MCC01 -A01-80 1 3 ST 2,5 (B.20A1.S1/46.4) +B4I.JB01 -X81 3 3
+B4I.MCC01 -A01-60 6 6 ST 2,5 (B.20A1.T2/48.4) +B4I.JB01 -X81 6 BR
+B4I.MCC01 -A01-60 10 7 ST 2,5 (B.20A1.T2/48.4) +B4I.JB01 -X81 7 WH
PE ST 2,5-PE (B.20A1.T2/48.4) +B4I.JB01 -X81 PE
PE -
+B4I.MCC01 -A01-60 5 4 ST 2,5 (B.20A1.T1/47.4) +B4I.JB01 -X81 4 BR
+B4I.MCC01 -A01-60 9 5 ST 2,5 (B.20A1.T1/47.4) +B4I.JB01 -X81 5 WH
PE (B.20A1.T1/47.4) +B4I.JB01 -X81 PE
+B4I.MCC01 -A02-03 IN 8 ST 2,5 (B.20A1.S1/46.4) +B4I.JB01 -X81 8 4

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 MCC Cabinet Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner Terminals Project no.: ZC133238545 Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 JB01 - Terminal diagram Customer: RECYCLING-STANDARD Page: 1 / 133 126 / 133
Standard: Order: Draw. no.:
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|MCC01|10|07|X81-JB10|ET-KLP.127

16:46:10
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Final date of print: 30.03.2020

Legend

+B4I.JB10-W81, Oelflex Classic 110 BK CY 4x1 / Ø 8mm


Connection input-output: Bridges:
Connection / Bridge GND Terminal Ridge bridge
Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket

Terminal strip
Manufacturer: PHOENIX CONTACT

Internal connected device +B4I.MCC01-X81-JB10 External connected device


Unit / Location Device Conn. Int. Symbol Ext. Label Type Bridges Reference Unit / Location Device Conn.
+B4I.MCC01 -A02-03 1+ 1 ST 2,5 (B.20A1.V1/49.3) +B4I.JB10 -X81 1 1
+B4I.MCC01 -A02-03 1- 2 ST 2,5 (B.20A1.V1/49.3)
+B4I.MCC01 -A02-03 2+ 3 ST 2,5 (B.20A1.V1/49.4) +B4I.JB10 -X81 2 2
+B4I.MCC01 -A02-03 2- 4 ST 2,5 (B.20A1.V1/49.4)
+B4I.MCC01 -A02-03 3+ 5 ST 2,5 (B.20A1.V1/49.5) +B4I.JB10 -X81 3 3
+B4I.MCC01 -A02-03 3- 6 ST 2,5 (B.20A1.V1/49.5) +B4I.JB10 -X81 4 4
PE ST 2,5-PE (B.20A1.V1/49.5) +B4I.JB10 -X81 PE
+B4I.JB10 -X81 PE SH1

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 MCC Cabinet Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner Terminals Project no.: ZC133238545 Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 JB10 - Terminal diagram Customer: RECYCLING-STANDARD Page: 1 / 133 127 / 133
Standard: Order: Draw. no.:
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|MCC01|10|07|X82-JB10|ET-KLP.128

16:46:11
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Final date of print: 30.03.2020

Legend
Connection input-output: Bridges:

+B4I.JB10-W82, Li2YCY PiMF 4x2x1,0 / Ø 13.0mm


Connection / Bridge GND Terminal Ridge bridge
Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket

Terminal strip
Manufacturer: PHOENIX CONTACT

Internal connected device +B4I.MCC01-X82-JB10 External connected device


Unit / Location Device Conn. Int. Symbol Ext. Label Type Bridges Reference Unit / Location Device Conn.
+B4I.MCC01 -A02-04 1+ 1 ST 2,5 (B.20A1.V2/50.4) +B4I.JB10 -X82 1 1OR
+B4I.MCC01 -A02-04 1- 2 ST 2,5 (B.20A1.V2/50.4) +B4I.JB10 -X82 2 1WH
PE ST 2,5-PE (B.20A1.V2/50.4) +B4I.JB10 -X82 PE
+B4I.MCC01 -A02-04 2+ 4 ST 2,5 (B.20A1.V3/51.4) +B4I.JB10 -X82 4 2OR
+B4I.MCC01 -A02-04 2- 5 ST 2,5 (B.20A1.V3/51.4) +B4I.JB10 -X82 5 2WH
PE ST 2,5-PE (B.20A1.V3/51.4) +B4I.JB10 -X82 PE

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 MCC Cabinet Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner Terminals Project no.: ZC133238545 Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 JB10 - Terminal diagram Customer: RECYCLING-STANDARD Page: 1 / 133 128 / 133
Standard: Order: Draw. no.:
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|4|I|.M|MCC01|10|01|X91|ET-KLP.129

16:46:12
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Final date of print: 30.03.2020

Legend

+B4I.JB02-W91, Oelflex Classic 110 BK CY 4x1 / Ø 8mm


Connection input-output: Bridges:
Connection / Bridge GND Terminal Ridge bridge
Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket

Terminal strip
Manufacturer: PHOENIX CONTACT

Internal connected device +B4I.MCC01-X91 External connected device


Unit / Location Device Conn. Int. Symbol Ext. Label Type Bridges Reference Unit / Location Device Conn.
+B4I.MCC01 -P4:1c P4:1c 1 ST 2,5 (B.25A1.V1/69.6) +B4I.JB02 -X91 1 1
+B4I.MCC01 -M:7c M:7c 2 ST 2,5 (B.25A1.V1/69.6) +B4I.JB02 -X91 2 2
+B4I.MCC01 -A01-70 1 3 ST 2,5 (B.25A1.V1/69.7) +B4I.JB02 -X91 4 3
+B4I.MCC01 -A01-70 ? 4 ST 2,5 (B.25A1.V1/69.7) +B4I.JB02 -X91 5 4

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 MCC Cabinet Project: RECYCLING-PRODUCTS Function Unit:
Created: Prettner Terminals Project no.: ZC133238545 Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 MCC - Terminal diagram Customer: RECYCLING-STANDARD Page: 1 / 133 129 / 133
Standard: Order: Draw. no.:
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|25|F1|M1|E|E|01|X1|ET-KLP.130

16:46:12
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Final date of print: 30.03.2020

Legend

B.25F1-M1-W01, Oelflex Classic 110 BK 4G2,5 / Ø 7.2mm


Connection input-output: Bridges:
Connection / Bridge GND Terminal Ridge bridge
Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket

Terminal strip
Manufacturer: PHOENIX CONTACT

Internal connected device B.25F1-M1+B4I.MCC01-X1 External connected device


Unit / Location Device Conn. Int. Symbol Ext. Label Type Bridges Reference Unit / Location Device Conn.
B.25F1-M1 +B4I.MCC01 -QA1 2 1 ST 2,5 (77.2) B.25F1 +B.Local.25 -M1 U1 1
B.25F1-M1 +B4I.MCC01 -QA1 4 2 ST 2,5 (77.2) B.25F1 +B.Local.25 -M1 N 2
B.25F1-M1 +B4I.MCC01 -QA1 6 3 ST 2,5 (77.2) B.25F1 +B.Local.25 -M1 W1 3
PE ST 2,5-PE (77.2) B.25F1 +B.Local.25 -M1 PE GNYE

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Hydraulic Cooler Project: RECYCLING-PRODUCTS Function Unit: B.25F1-M1
Created: Prettner MCC Project no.: M Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 Terminal diagram Customer: RECYCLING-STANDARD Page: 1 / 133 130 / 133
Standard: Order: Draw. no.:
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|25|P1|M1|E1|E|01|X1|ET-KLP.131

16:46:13
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Final date of print: 30.03.2020

Legend

B.25P1-M1-W01, Oelflex Classic 110 BK 4G6 / Ø 7.2mm


Connection input-output: Bridges:
Connection / Bridge GND Terminal Ridge bridge
Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket

Terminal strip
Manufacturer: PHOENIX CONTACT

Internal connected device B.25P1-M1+B4I.MCC01-X1 External connected device


Unit / Location Device Conn. Int. Symbol Ext. Label Type Bridges Reference Unit / Location Device Conn.
B.25P1-M1 +B4I.MCC01 -QA1 2 1 ST 6 (78.2) B.25P1 +B.Local.25 -M1 U1 1
B.25P1-M1 +B4I.MCC01 -QA1 4 2 ST 6 (78.2) B.25P1 +B.Local.25 -M1 V1 2
B.25P1-M1 +B4I.MCC01 -QA1 6 3 ST 6 (78.2) B.25P1 +B.Local.25 -M1 W1 3
PE ST 6-PE (78.2) B.25P1 +B.Local.25 -M1 PE GNYE

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Hydraulic Pump Project: RECYCLING-PRODUCTS Function Unit: B.25P1-M1
Created: Prettner MCC Project no.: M Location: +B4I.MCC01
Checked: Pereira-Perez / 05.03.2020 Terminal diagram Customer: RECYCLING-STANDARD Page: 1 / 133 131 / 133
Standard: Order: Draw. no.:
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|30|H1|M1|E|E|01|X1|ET-KLP.132

16:46:14
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Final date of print: 30.03.2020

Legend
Connection input-output: Bridges:
Connection / Bridge GND Terminal Ridge bridge

B.30H1-M1-W01, NYCY 4 x 4 RE/ 4 / Ø 18mm


Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket

Terminal strip
Manufacturer: PHOENIX CONTACT

Internal connected device B.30H1-M1-X1 External connected device


Unit / Location Device Conn. Int. Symbol Ext. Label Type Bridges Reference Unit / Location Device Conn.
B.30H1-M1 +B4I.MCC02 -TA1 U 1 ST 4 (79.2) B.30H1 -M1 U1 BN
B.30H1-M1 +B4I.MCC02 -TA1 V 2 ST 4 (79.2) B.30H1 -M1 V1 BK
B.30H1-M1 +B4I.MCC02 -TA1 W 3 ST 4 (79.2) B.30H1 -M1 W1 GY
B.30H1-M1 +B4I.MCC02 -TA1 PE PE ST 4-PE (79.2) B.30H1 -M1 PE GNYE

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Discharge Conveyor 1 Project: RECYCLING-PRODUCTS Function Unit: B.30H1-M1
Created: Prettner MCC Project no.: M Location:
Checked: Pereira-Perez / 05.03.2020 Terminal diagram Customer: RECYCLING-STANDARD Page: 1 / 133 132 / 133
Standard: Order: Draw. no.:
CAE: RECYCLING-PRODUCTS/GRZ:300_FRAN|B|30|H1|M1|E|E|01|X2|ET-KLP.133

16:46:14
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Final date of print: 30.03.2020

Legend

B.30H1-M1-W21, Oelflex Classic 110 BK 3G2,5 / Ø 6.7mm


Connection input-output: Bridges:
Connection / Bridge GND Terminal Ridge bridge
Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket

Terminal strip

Internal connected device B.30H1-M1-X2 External connected device


Unit / Location Device Conn. Int. Symbol Ext. Label Bridges Reference Unit / Location Device Conn.
B.30H1-M1 -QA3 2 1 (79.6) B.30H1-M1 -MB2 1 1
B.30H1-M1 -QA3 4 2 (79.6) B.30H1-M1 -MB2 2 2
PE (79.6) B.30H1-M1 -MB2 PE GNYE

Rev. Rev.Date Created Checked Description of Revision Crea.Date: 05.03.2020 Discharge Conveyor 1 Project: RECYCLING-PRODUCTS Function Unit: B.30H1-M1
Created: Prettner MCC Project no.: M Location:
Checked: Pereira-Perez / 05.03.2020 Terminal diagram Customer: RECYCLING-STANDARD Page: 1 / 133 133 / 133
Standard: Order: Draw. no.: