TCC 151

This document describes a rapid-rate thermal cycle chamber that can achieve temperature changes of 23°C/min and specimen temperature control of 15°C/min. It features a built-in web application to remotely monitor and control the chamber. The chamber allows for accurate life testing to standards like JEDEC by maintaining consistent temperature ramp rates and symmetrical temperature profiles for specimens, improving testing reproducibility.

Uploaded by

Chad Cures
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
132 views16 pages

TCC 151

This document describes a rapid-rate thermal cycle chamber that can achieve temperature changes of 23°C/min and specimen temperature control of 15°C/min. It features a built-in web application to remotely monitor and control the chamber. The chamber allows for accurate life testing to standards like JEDEC by maintaining consistent temperature ramp rates and symmetrical temperature profiles for specimens, improving testing reproducibility.

Uploaded by

Chad Cures
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 16

Rapid-Rate Thermal Cycle Chamber

TCC-151W

CAT.NO.E20132
A thermal cycle chamber that achieves a
temperature change rate of 23℃/min. and
specimen temperature ramp control of 15℃/min.
Used for everything from JEDEC standard testing to screening,
this rapid-rate thermal cycle chamber rapidly changes air temperature while controlling
specimen temperature.
It features a built-in web application that can be used to operate the chamber from a PC or tablet.
This web application allows you to check the status of the chamber
remotely using a web browser.

A rapid-rate thermal cycle chamber and environmental stress chamber

25
HRG-357HS-25 HRG-600HS-25 HRG-800HS-25 HRG-1800HS-25
Temperature pull-down rate (K / min.)

TCC-151W
Heat-up HRG-357HS-20 HRG-600HS-20 HRG-800HS-20 HRG-1800HS-20
20 23℃/min.

ARGF-0250-15

TCC-151W
Cool-down
18℃/min.
15
ARGF-0400-15 ARGF-0800-15

10

250 500 750 1000 1800


Test area capacity (L)

* Temp. rate of change according to IEC 60068-3-5


* Set conditions: +180℃、 −70℃

1
Rapid-Rate Thermal Cycle Chamber TCC-151W

* Shown are equipped with options.

ARGF

HRG

2
Performance

For accurate life evaluation testing that meets JEDEC standard

Specimen temperature ramp control (example) Fatigue life depends on the rate of strain
■ Specimen
and the strain waveform. In the case of
temperature control data
thermal cycle chambers, the strain rate
140
125 Setting f l u c tu ate s b a s e d o n th e te m p e r atu re
temperature change rate, while the strain waveform is
100
influenced by the symmetry of the specimen
Specimen
te mpe rature change wavefor m dur ing
Temperature (℃)

60 temperature
temperature increase and decrease.
20

Guaranteed ramp rate


−20 control range
−40
Highly reproducible ramp
−60 control
0 5 10 15 20 25 30 35 40 45 50
Time (min.) Using the TCC specimen temperature
Test conditions ramp control, the ramp rate can be
High temp. soak : +130℃ Control point : Front center specimen regulated so that strain waveforms can
Low temp. soak : −45℃ on the lower level
Ramp rate : 15℃/min. Specimen : Printed Circuit Board, be symmetrical.
145 × 130 mm, 90 pcs.
Measurement method
Furthermore, the strain rate can be held
45 specimens placed in two rows on two levels in the specimen basket, constant even if the number of samples
with thermocouples attached to the surface of each specimen at the control point.
is different per test, by maintaining the
same ramp rate. This allows tests to be
carried out with exceptionally high
reproducibility.
Distribution performance during temperature changes (example)
■ Distribution data during temperature changes
140
Meet JESD22-A104E
120
100 Standard tests that require specimen
80 temperature ramp rates of 15 ℃ per
minute or less (−40 to + 125℃ ) can be
Temperature (℃)

60
40 carried out with ease and accuracy.
20 In addition, this chamber is also designed
0 to execute tests at a temperature change
−20 rate of 10 to 15℃ per minute as stated
−40 in  IEC60749-25 and at 15℃ per minute
−60
0 10 20 30 40 50
mentioned in JESD22-A104E.
Time (min.) T h is cha mbe r is ideal ly su it e d t o
■ Temperature rate of change at twelve measuring points (Average) automotive test requi rements, life
* Conforms to IEC60068-3-5: 2001 assessments for solder joi nts, and
Temperature rate of change (℃/min.)

25
reliability assessments for semiconductor
For temperature heat up: 13.9 to 15.1℃/min.
20 For temperature pull down: 14.9 to 15.4℃/min. devices and packages.
15

10
Maximized temperature
5 uniformity for equal thermal
load to the specimen
0
1 2 3 4 5 6 7 8 9 10 11 12
Measuring point

Test conditions
High temp. soak : +125℃ Specimen : Printed Circuit Board,
Low temp. soak : −40℃ 145 × 130 mm, ⑥ ⑤ ④
Ramp rate : 15℃/min. 90 pcs.
Control point : Air outlet sensor ③ ② ①
⑫ ⑪ ⑩
Measurement method
As shown on the right, thermocouples are attached to ⑨ ⑧ ⑦
the specimens at twelve measuring points.

3
Performance

Dual-side wiring for enhanced


operability
The chamber comes with 25 × 100mm
oval cable ports on both the left and
right sides for the simple wiring of flat
cables. The internal dimension of the
chamber are W800 × H500 × D400
mm, and the capacity is 160 L.
* Accommodates approximately 60 B5-sized
(176 × 250 mm) boards in an upright position.

The integrated control panel


on the door maximizes usable
space inside the chamber.

Test area
Specimen can be inserted or
removed during testing
Testing can be paused upon completion
of any given cycle. Specimen can be
inserted or removed during testing,
enabling joint testing to reduce overall
test time.

Conductor resistance
evaluations
The TCC can be used in conjunction
with the Espec Resistance Evaluation
System (AMR) (sold separately) used
for continuos measurement of micro
resistance of conductor components,
such as solder joints under temperature
cycle conditions, allowing for real-time
detection of micro-crack formation. Example of connection between Conductor Resistance Evaluation System (AMR) and TCC
I n a d d it ion , ef fe c t ive s che d u l i ng
management has been facilitated by the
integration of automatic measurement
and data logging systems.

Complies with international


safety standards
ISO 12100, Safety of machinery
IEC 60204-1, Low voltage
EMC IEC 61000-6-2, 6-4

4
Controller
N-instrumentation P-310

High-resolution 7-inch display

Ramp rate input available


(patent pending) NEW

T he step ti me can be calculated


automatically just by inputting the ramp
rate.

Email alert Convenient notification


function
INFO icon f lashes to show chamber
information, such as door ajarPC
alarm
PC and whatever you select.
Ethernet Intranet
(company LAN) 携帯電話
スマートフォン
Mail server
TCC-151W Mobile phone
タブレットコントローラー
Multi-language support
(オプション)
You can change the language of the
controller by pressing the Language
icon and choosing the language. You
Program Copy and Computer Editing
can select f rom Japanese, English,
Tr a d i t i o n a l C h i n e s e , Si m p l i f i e d
Chinese, and Korean.
Copy

TCC-151W TCC-151W
Test profile copying without a PC
小型環境試験器
Edit
The chamber comes with(Wi-Fia USB機能搭載)
port
※Some items may not be copied between different models chambers with different options. that can be used with USB memory
devices (not included) to share test
profiles with other chambers.

Network 無線 LAN による接続例


Wi-Fi ルーター
Wi-Fi router (オプション)

PC

Ethernet Ethernet
スマートフ
小型環境試験器
Smartphone Tablet controller
TCC-151W 内蔵ワイヤレスダイレクトによ
5 ワイヤレスダイレクト
(オプション)
PC
Ethernet Intranet
(company LAN)

Networks TCC-151W
Mail server

Mobile phone
* An Intranet environment is required. Supported browser:Internet Explorer 11

Test-supporting network functions


Program Copy and Computer Editing
Remote monitoring and control
(via Ethernet connection)
The chamber is equipped with a web
application that enables monitoring of Copy
the chamber status and operation from a
web browser, which ensures operability
from a remote location.
Passwords for user-level access can also
be set using the web browser. TCC-151W TCC-151W

Edit

Editing test profiles via a


browser
Image
It is possible to edit the test profiles
環境試験器や周辺器機を一括管理
registered in the chamber using a web
browser. Network
エスペック オンラインコア(別売)
Wi-Fi router
Email alarm notification
イントラネットに接続するだけで
環境試験室
環境試験器
Det ai ls on ala r m s t h at h ave b e e n 試験データ PC
Webブラウザーから稼働状況を
triggered will be sent to pre-registered
一目でモニターできます。
e-mail addresses. It is also possible to
素早いメンテナンス対応など Ethernet
t ransmit e-mails when testing has
装置の集中管理が行えます。 計測器
finished. Smartphone Tablet controller
*An※接続対象機種はお問い合わせください。
Intranet environment is required to transmit TCC-151W ネットワーク
e-mails. カメラ

エスペック オンラインサポート 遠隔作業支援 装置管理サポート

「安心」

・ 安全」
につながるアフターサービス

Centralized management of environmental test chambers and peripheral devices

ESPEC OnlineCore (Sold separately)

Operating status can be quickly ascertained


via a web browser just by connecting to an
Environmental
Intranet environment. This enables test area
Environmental
chambers to be managed centrally to Test data test chamber
enable speedy maintenance, etc.

* Inquire regarding types of models


Measuring
that can be connected. instrument

OnlineCore Network
camera

6
SPECIFICATIONS

Model TCC−151W
System Balanced Temperature Control system (BTC system)
Temperature range −70 to +180℃ (−94 to +356℉)
±0.5℃
Temperature fluctuation
−70 to +180℃, after temperature stabilization
−45 → +155℃ *2 +155 → −45℃ *2 −23.5 → +108.5℃ +108.5 → −23.5℃ +108.5 ⇔ −23.5℃
Temperature range Target temp.: Target temp.: Target temp.: Target temp.: Target temp.:
Performance *1

−70 → +180℃ +180 → −70℃ −40 → +125℃ +125 → −40℃ +125 ⇔ −40℃

Temperature Specimen None None None None Yes *3


change Chamber temp. or
Control target Chamber temp. Chamber temp. Chamber temp. Chamber temp.
Specimen temp.
Ramp control Off Off Off Off On
Performance 23℃/ min. 18℃/ min. 26℃/ min. 20℃/ min. 15℃/ min.
Allowable heat load 8 kW (−20℃ or more)
Exterior material Cold-rolled rust-proofed steel plate
Interior material 18-8 Cr-Ni Stainless steel plate
Chamber body: Foamed polyurethane, glass wool
Insulation
Door: Glass wool, formed resin
Door Single door (hinge on left, handle on right)
Construction

Heater Nichrome strip wire heater


System Mechanical cascade refrigeration system (water-cooled condenser)

Refrigeration Compressor Scroll-type


unit Expansion system Electronic expansion valve
Refrigerant R404A, R23
Cooler Plate fin cooler
Air circulator Sirocco fan
Chamber total load resistance 50 kg
Inside dimensions *4 W800 × H500 × D400 mm
Outside dimensions *4 W1000 × H1808 × D1915 mm
Capacity 160 L
Weight 950 kg
Allowable ambient conditions +5 to +35℃ (+41 to +95℉)
200V AC 3φ 50/60Hz 115A
220V AC 3φ 60Hz 111A
Utility requirements

Power supply
380V AC 3φ 50Hz 61A
400V AC 3φ 50Hz 60A
Cooling water supply pressure *5 0.2 to 0.5 Mpa (2 to 5 kg/cm2G)
Cooling water supply rate *6 4100L/h (at reference water temp. +25℃)
Piping connection size Carbon steel pipe, ID 32 mm (drain and supply)
Operating cooling water temp. range +5 to +32℃ (+41 to +89.6℉)
Noise level *7 Max. 65 dB
*1 The performance values are based on IEC60068-3-5:2006, and JTM K07:2007, under the conditions of a +23℃ ambient temperature,
cooling water temperature +25℃, rated voltage, and no specimen.
*2 Refer to Fig on page 8.
*3 Specimen: (glass epoxy PCB) 5kg + Jig: 4kg (ESPEC standard jig)
*4 Excluding protrusions.
*5 Rate depends on the cleanliness of the heat exchanger
*6 A pressure regulator valve is required if the pressure exceeds 0.5MPa (5kg/ cm2G)
*7 Noise level was measured in an anechoic room at a height of 1.2 m from the floor and a distance of 1 m from the chamber front panel
(JIS-Z-8731:1999 A-weighted sound pressure level).

7
TEMPERATURE CHANGE GRAPH

200
180
Temperature range: −45 to +155℃ (setting: −70, +180℃)
160 +155 to −45℃ (setting: +180, −70℃)
140 Specimen load: None
120 Temperature control: Chamber temperature
Temperature (℃)

100 Ramp control: Off


80 Performance: Max. 9 min. (32℃ or more/min.)
60
Max. 11 min. (18℃ or more/min.)
40
20
0
−20
−40
−60
−80
0 5 10 15 20
Time (min.)

DIMENSIONS/FITTINGS LOCATION

Unit: mm
Ethernet port (LAN port)
Specimen power supply
control terminal
Time signal × 2
Specimen temperature
input terminal

Overheat protector USB port

Cable port
Power supply φ25×100㎜,
cable port right & left side
160

RS-485

ETHERNET

試料電源制御出力
POWER SUPPLY
CONTROL
FOR SPECIMEN
No.1

No.2
タイムシグナル出力

Drain pipe for cooling water


TIME SIGNALS

記録計用出力
RECORDER OUTPUT
空気温度 (JIS T )
CHAMBER (TYPE T)
TEMPERATURE

試料温度 (JIS T )
SPECIMEN (TYPE T)
TEMPERATURE

試料温度入力
(JIS T )

SPECIMEN
TEMPERATUREINPUT
(TYPE T)
500

状態出力
STATUS OUTPUT
COM
NO
NC

Water supply pipe for


1808

設定温度到達出力
TEMP. ATTAINMENT
OUTPUT
扉開閉時出力
DOOR OPENING
SIGNAL OUTPUT

cooling water サーキッ


100V コンセント
POWER OUTLET

トプロテクタ
CIRCUIT PROTECTOR

試料制御用
FOR SPECIMEN

TOTAL 100V AC 3A

計測器用
FOR INSTRUMENT

Drain pipe

400 1000
1915

8
SAFETY DEVICES ACCESSORIES
• Leakage breaker for 200, 220, 380V AC supply • Flat cable port rubber plug (Silicone sponge rubber) 2
• Circuit breaker for 400V AC supply • Specimen basket 2
• Mechanical compartment cover and (18-8 Cr-Ni stainless steel: 5 mesh per inch)
electrical compartment door switch W700×H40×D346 mm/ load capacity 5kg
• Thermal fuse for control circuit short-circuit protection
• System error
• Motor reverse prevention relay
• Thermal fuse
• Air circulator short-circuit protection
• Air circulator Thermal switch
• Overheat protector
• Temp upper limit deviation alarm
• Temp upper / lower limit absolute alarm
• Chamber door switch
• Room temperature compensation burn-out detection circuit • Shelf brackets (7 positions available, pitch 60mm) 4
• Dry bulb temperature burn-out detection circuit • Cartridge fuse
• Product temperature burn-out detection circuit 200V AC
(only when product temperature control) Type B, 250V 6A 1
• Specimen power supply control terminal 250V 4A 1
• Cooling water pressure switch 220V AC, 380V AC, 400V AC
• Heater overcurrent protection Type B, 250V 4A 1
• Refrigeration circuit temperature burn-out detection circuit 250V 5A 1
• Refrigerator short-circuit protection 250V 6A 1
• Refrigerator overcurrent protection • Specimen temperature measuring thermocouple 1
• Refrigerator high/low pressure switch • Specimen temperature input connector 1
• Cooling tower interlock terminal • Strainer R11/4 in. (32A) 1
• Nipple R11/4 in. (32A) 1
• Strainer element (#30 mesh) 1
• Operation manual 1 set
• Warranty card 1
*Power cable is optional, not equipped as standard fitting.

Safety precautions
● Do not use specimens which are explosive or inflammable, or which contain such
substances. To do so could be hazardous, as this may lead to fire or explosion.
● Do not place corrosive materials in the chamber. If corrosive substances or liquid
is used, the life of the unit may be significantly shortened specifically because of
the corrosion of stainless steel, resin and silicone materials.
● Do not place life forms or substances that exceed allowable heat generation.
● Be sure to read the operation manual before operation.

9
TEST STANDARD (TCC-151W COMPATIBILTY)

Temperature setting Temperature


Test standard Soak time Number of cycles
High temperature (℃) Low temperature (℃) change rate

G +125 (+15, − 0) −40 (+ 0, −10)


I +115 (+15, − 0) −40 (+ 0, −10)
J +100 (+15, − 0) 0 (+ 0, −10)
JESD22-A104E K +125 (+15, − 0) 0 (+ 0, −10)
L +110 (+15, − 0) −55 (+ 0, −10)
N +80 (+15, − 0) −40 (+ 0, −10)
R +125 (+15, − 0) −25 (+ 0, −10) Specimen temperature,
1, 5, 10, 15 min. Not specified
G +125 (+15, − 0) −40 (+ 0, −10) 15℃ / min. or less

I +115 (+15, − 0) −40 (+ 0, −10)


J +100 (+15, − 0) 0 (+ 0, −10)
IEC 60749-25 K +125 (+15, − 0) 0 (+ 0, −10)
L +110 (+15, − 0) −55 (+ 0, −10)
N +80 (+15, − 0) −30 (+ 0, −10)
O +125 (+15, − 0) −25 (+ 0, −10)

+175 ±2
1± 0.2K / min.
+155 ±2 3 hours,
− 65 ±3 3± 0.6K / min.
+125 ±2 2 hours,
−55 ±3 5±1K / min.
+100 ±2 1 hour,
IEC 60068-2-14 Nb −40 ±3 10± 2K / min.
+85 ±2 30 min., 2
(JIS C 60068-2-14 Nb) −25 ±3 15± 2K / min.
+70 ±2 10 min.
−5 ±3 (AVG)
+55 ±2 3 hours if not specified in
+5 ±3 Average for
+40 ±2 product specifications
up to five minutes
+30 ±2

+100 ±2
+95 ±2
+90 ±2 −50 ±3
+85 ±2 −45 ±3
+80 ±2 −40 ±3 3 hours,
1± 0.2℃ / min.
+75 ±2 −35 ±3 2 hours,
3± 0.6℃ / min.
+70 ±2 −30 ±3 1 hour,
IEC-61747-5 5±1.0℃ / min.
+65 ±2 −25 ±3 30 min., 2
(EIAJ ED-2531B) (AVG)
+60 ±2 −20 ±3 10 min.
Average for
+55 ±2 −15 ±3 3 hours if not specified in
up to five minutes
+50 ±2 −10 ±3 product specifications
+45 ±2 −5 ±3
+40 ±2 0 ±3
+35 ±2
+30 ±2

A +85 (+10, − 0) −40 (+ 0, −10) 6.25℃ / min.


JESD22-A105C 10 min. 1000
B +125 (+10, − 0) −40 (+ 0, −10) 5.5℃ / min.
TC1 100 0
200
TC2 100 −25
500
Specimen temperature, Specimen temperature,
IPC-9701 TC3 125 −40 1000
20℃ / min. or less 10 min.
3000
TC4 125 −55
6000
TC5 100 −55
A +125 (+3, − 0) − 65 (+ 0, −5)
IPC-TM-650 2.6.6 — 30 min. 5
B +85 (+3, − 0) −55 (+ 0, −5)
LV 124 L-03 — 4℃ / min. 15 min. —
SAE-J1211 +85〜+150 −40 4 to 6℃ / min. Low temperature, 4 hours —

10
Unit: mm
Ethernet port (LAN port)
Specimen power supply
OPTIONS control terminal
Time signal × 2
Specimen temperature
Power cable input terminal Additional cable port Paperless recorder

・ 5 m Provided in addition to the standard Records temperature of each section


・ 10 m cable ports. (Right & left sides) such as the temperature inside the
* Power cable is optional, not equipped as Location: Right & left side of the Overheat main protector chamber. USB port
standard fitting. unit Display: 5.7inch color touch panel
Cable port
Internal diameter: φ25 × 100 mm φ25×100㎜,Number of inputs (Initial setting):
Power supply
* This cable port cable
cannotport field.& left side
be retrofitted on theright 2 (4 more channels can be turned ON)
Specimen basket / shelf bracket Data saving cycle: 5 seconds
Temperature range: −100 to +220℃
Equivalent to standard accessory. Internal memory: 8MB
・Material: Stainless steel (5 mesh) External memory media:
CF memory card (256 MB)
External memory function: USB port

160
RS-485

ETHERNET

試料電源制御出力
POWER SUPPLY
CONTROL
FOR SPECIMEN
No.1

No.2
タイムシグナル出力

Drain pipe for cooling water


TIME SIGNALS

記録計用出力

Cable port rubber plug


RECORDER OUTPUT
空気温度 (JIS T )
CHAMBER (TYPE T)
TEMPERATURE

試料温度 (JIS T )
SPECIMEN (TYPE T)
TEMPERATURE

試料温度入力
(JIS T )

SPECIMEN
TEMPERATUREINPUT
(TYPE T)

500
状態出力
STATUS OUTPUT
COM
NO
NC

Water supply pipe for

1808
設定温度到達出力
TEMP. ATTAINMENT

Prevents air leakage from the cable


OUTPUT
扉開閉時出力
DOOR OPENING
SIGNAL OUTPUT

cooling water
port.
100V コンセント
POWER OUTLET

サーキッ
トプロテクタ
CIRCUIT PROTECTOR

試料制御用
FOR SPECIMEN

TOTAL 100V AC 3A

計測器用
FOR INSTRUMENT

Drain pipe

Chart recorder
Interface 400 1000
1915 −100 to +220℃ /100 mm
・ RS-485 ・RK-63: 3 pens
・ RS-232C ・RK-64: 6 dots
・ GPIB
Location: Terminal panel
Recorder wiring

Communication cables Preparation of a power cable, tempera-


ture sensor, and a grounding wire for
・ RS-485 5m/ 10m/ 30m additional installation in the future.
・ GPIB 2m/ 4m

Recorder terminal

Used to output the temperature within


test area and specimen temperature.

RS-485

ETHERNET

試料電源制御出力
Additional cable port
POWER SUPPLY
CONTROL
FOR SPECIMEN
No.1

No.2
タイムシグナル出力
TIME SIGNALS

記録計用出力
RECORDER OUTPUT
空気温度 (JIS T )
CHAMBER (TYPE T)
TEMPERATURE

試料温度 (JIS T )
SPECIMEN (TYPE T)
TEMPERATURE

試料温度入力
(JIS T )

SPECIMEN
TEMPERATUREINPUT
(TYPE T)

Cable port
Terminal panel Emergency
状態出力
STATUS OUTPUT
COM
NO
NC

設定温度到達出力
TEMP. ATTAINMENT
OUTPUT
扉開閉時出力
DOOR OPENING
SIGNAL OUTPUT
stop pushbutton
100V コンセント
POWER OUTLET

サーキッ
トプロテクタ
CIRCUIT PROTECTOR

試料制御用
FOR SPECIMEN

TOTAL 100V AC 3A

計測器用
FOR INSTRUMENT

Recorder

〈Left side〉 〈Front〉

11
OPTIONS

Thermocouple Status output terminal Anchoring fixtures

Attached to specimens to measure When the chamber is setting operation Used to bolt the chamber to the floor.
specimen temperature. such as “Error”, interlock with
・Thermocouple type T without ball connecting devices.
 (Copper/ Copper-Nickel) Chamber dew tray
* Same as accessory items
Operation:
When connecting with N.O. contact Prevents water leaks from the chamber
(normally open contact), output onto the floor.
Temperature attainment output “close” contact.
When connecting with N.C. contact
When the temperature in the chamber (normally close contact), output
reaches the set values, the chamber “open” contact.
sends out a contact signal. Power supply capacity: 250 V AC, 3 A
Accessory: Plug
Location: Terminal panel
Additional overheat protector Right side or within the control
board (retrofit is not available)
Additional preventive measures can be Image
*The circuit shall be connected by customer.
taken for excessive temperature rise in
t h e c h a m b e r, i n a d d it io n t o t h e *To prevent damage in the event of water
standard equipped overheat protector. Status indicator light leakage, other preventive measures are
also available.
Select light color, lighting, and
blinking or buzzer sound.
Overcool protector
• 1 level, light: 1 color, height: 534 mm
If the temperature inside the chamber • 2 levels, light: 2 colors, height: 574 mm Casters
• 3 levels, light: 3 colors, height: 614 mm
decreases excessively, the chamber
stops operating to prevent the speci- • 4 levels, light: 4 colors, height: 654 mm Installed for mobility.
mens from being damaged. Pole length: 290 mm Casters: 4
* T he pole can be shortened in units of Levelling-feet: 4
10 mm to a minimum height of 50 mm.

Door opening signal output terminal


Operation manual
Equips the chamber with a terminal
• CD
that outputs the door open status.
• Booklet
Capable of controlling an external
device that operates along with door
operation and records the temperature Reports & certificates
disturbance history.
・ Testing and inspection report
・ Test data
・ Calibration report
Emergency stop pushbutton
・ Calibration certificate
・ Traceability certificate
Stops the chamber immediately.
・ Traceability system chart

With guard With cover

■Some photographs presented in this catalog contain Japanese display.


12
ARGF

Model *1 ARGF-0250-15 ARGF-0400-15 ARGF-0800-15


Temperature range −70 to +180℃ (−94 to +356℉)
Temp. performance *2

Temperature fluctuation ±0.3K

Temp. rate Heat up rate 18K/min. 15K/min. 15K/min.


of change Pull down rate 18K/min. 15K/min. 15K/min.
Test area temperature: +20°C
Allowable heat load
6000W 9000W
Capacity 249L 398L 784L
Inside dimensions mm *3 W600×H830×D500 W600×H830×D800 W1000×H980×D800
Outside dimensions mm *3 W800×H1703×D1900 W800×H1703×D2200 W1200×H1853×D2200
*1: Temperature and humidity models also available.
*2: The performance values are based on IEC60068-3-5:2001 and IEC60068-3-6:2001; Performance figures are given for a +23°C,
ambient temperature relative humidity of 65±20%rh, rated voltage, and no specimen inside the test area.
*3: Dimensions do not include protrusions.

13
HRG

Image

HRG- HRG- HRG- HRG- HRG- HRG- HRG- HRG-


Model *1
357HS-20 600HS-20 800HS-20 1800HS-20 357HS-25 600HS-25 800HS-25 1800HS-25
Temperature range −70 to +180℃ (−94 to +356℉)

Temp. rate Heat up rate 20K/min. 25K/min.


of change Pull down rate 20K/min. 25K/min.
700 1000 1000 1500 700 1000 1000 1500
Inside dimensions
850 1000 1000 1200 850 1000 1000 1200
(W×H×Dmm) *2
600 600 800 1000 600 600 800 1000
Capacity 357L 600L 800L 1800L 357L 600L 800L 1800L
*1: Temperature and humidity models also available.
*2 Dimensions do not include protrusions.

14
https://www.espec.co.jp/english
Head Office
3-5-6, Tenjinbashi, Kita-ku, Osaka 530-8550, Japan
Tel : 81-6-6358-4741 Fax : 81-6-6358-5500

ESPEC NORTH AMERICA, INC.


Tel : 1-616-896-6100 Fax : 1-616-896-6150
ESPEC EUROPE GmbH
Tel : 49-211-361850-0
ESPEC ENVIRONMENTAL CHAMBERS
SALES AND ENGINEERING LTD. STI. (Turkey)
Tel : 90-212-438-1841 Fax : 90-212-438-1871
ESPEC ENVIRONMENTAL EQUIPMENT (SHANGHAI) CO., LTD.
Head Office
Tel : 86-21-51036677 Fax : 86-21-63372237
BEIJING Branch
Tel : 86-10-64627025 Fax : 86-10-64627036
GUANGZHOU Branch
Tel : 86-20-83317826 Fax : 86-20-83317825
SHENZHEN Branch
Tel : 86-755-83674422 Fax : 86-755-83674228
SUZHOU Branch
Tel : 86-512-68028890 Fax : 86-512-68028860
TIANJIN Branch
Tel : 86-22-26210366 Fax : 86-22-26282186
XI’AN Branch
Tel : 86-29-88312908 Fax : 86-29-88455957
CHENGDU Branch
Tel : 86-28-88457756 Fax : 86-28-88474456
WUXI Branch
Tel : 86-510-82735036 Fax : 86-510-82735039
ESPEC TEST TECHNOLOGY (SHANGHAI) CO., LTD.
Tel : 86-21-68798008 Fax : 86-21-68798088
ESPEC ENGINEERING (THAILAND) CO., LTD.
Tel : 66-3-810-9353 Fax : 66-3-810-9356
ESPEC ENGINEERING VIETNAM CO., LTD.
Tel : 84-24-22208811 Fax : 84-24-22208822

● Specifications are subject to change without notice due to design improvements.


TT3B02C03 (The contents of this catalog is as of February, 2020.) ● Corporate names and trade names mentioned in this catalog are trademarks or registered trademarks.

You might also like