Energy-Saving Ventilation Catalogue
Energy-Saving Ventilation Catalogue
2020
4 VENTS. Domestic ventilation. Catalogue №6 | 02-2020
CONTENT
Access doors for accessing concealed equipment and utility lines.......................... 388-400
CENTRIFUGAL FANS
Thyristor controllers
Fan control unit
page SRS-1, RS-1-300, page
BU-1-60 175
174 RS-1-400, RS-…N (V)
Supply and exhaust grilles page Supply and exhaust grilles page
MV 100 Series 194 MV 101 Series 196
Supply and exhaust grilles page Supply and exhaust grilles page
MV 120 Series 198 MV 121 Series 200
Supply and exhaust grilles page Supply and exhaust grilles page
MV 125, MV 125-1 Series 202 MV 126, MV 126-1 Series 204
Supply and exhaust grilles page Supply and exhaust grilles page
MV 150 V Series 206 MV 151 V Series 207
Supply and exhaust grilles page Supply and exhaust grilles page
MV 150, MV 150-1 Series 208 MV 160 Series 210
Supply and exhaust grilles page Supply and exhaust grilles page
MV 170 Series 211 MV 250, MV 250-1 Series 212
Exhaust grilles
Exhaust grilles page
MV 100 KV, MV 120 KV, page
MV 100 K, MV 125 K Series 228 229
MV 125 KV Series
Supply and exhaust grilles page Supply and exhaust grilles page
MV 100 V ASA series 232 MV 120 ASA series 233
Exhaust grilles
Exhaust grilles page
MV 120 J ASA, page
MV 100 J ASA series 238 239
MV 150 VJ ASA series
Supply plastic air disk valves page Supply plastic air disk valves page
A…PR Series 258 A…PRF Series 260
Stainless steel
page
non-insulated air ducts
Thermovent Aero Flex series 338
page
Round duct Round telescopic duct page
366 367
page
Round flexible duct connector 90° bend for round ducts page
367 367
page
45° bend for round ducts page T-joint for round ducts
368 368
page
Wall plate for round ducts page Round duct connector
368 369
page
Reducer page Step round reducer
372 372
page
Eccentric reducer Round to flat connector page
373 373
page
Round flexible duct connector 374 Holder for round ducts page
374
page
Flat duct 375 Flat duct connector page
376
Vertical 90° bend for page Horizontal 90° bend for page
flat ducts 378 flat ducts 379
page
Wall plate for flat ducts 382 End grille page
382
End grille with air pass page Reducer for flat and page
regulation 383 round ducts 383
page
Round duct 387 Flat duct page
387
Supply and exhaust grilles page Supply and exhaust grilles page
NHN (NUN) series 404 NVN (NUN) series 404
Supply and exhaust grilles page Supply and exhaust grilles page
GR series 406 RD series 410
Single-row unregulated
Single-row unregulated grilles page
linear grilles page
ONG, ONV 420 422
ONL
Single-row unregulated
Single-row unregulated grilles page
page sectional grilles
ONF, ONFS 424 424
ONK
page
Air flow regulator
459
from outside the oxygen content decreases, humidity and dustiness level increase. If ex-
haust ventilation is not provided or it is not effective, polluted air, smells, humidity and
harmful substances are not removed.
Well coordinated operation of supply and exhaust air vents is one more important factor
for properly arrangement of ventilation system. In case of exhaust ventilation only (i.e.
exhaust ventilation in the bathroom) air from outside flows through all possible gaps in
windows, doors and walling. Such non-arranged air supply brings dust ingress, smells and
drafts.
The door grilles installed in the bathrooms, wall or window vents, open windows or win-
dow leaves serve as natural sources of supply ventilation and are used to compensate air
removal. However, forced mechanical ventilation with centralized air supply and distribu-
What is ventilation? tion is a much better solution.
Ventilation is a complex of actions and facilities used for air exchange arrangement to Calculation of the required air exchange
provide the specified air condition in the premises and in working places. Engineering recommendations
Ventilation systems maintain admissible meteorological parameters in various premises.
Ventilation system should create the internal atmosphere that meets the specified hy- Effective ventilation depends on fan or ventilation system selection with suitable air flow
gienic standards and technological requirements. that meets your requirements.
Some factors to be considered:
What is ventilation required for? – Ventilated area volume
– Air exchange by the hour
We are surrounded with air and breathe in and out 20 000 litres of air every day. How much Multiple the ventilated premise volume by air exchange per hour and get the required fan
healthy is the air we breath in? capacity.
There is a range of aspects to determine air quality. Air exchange calculation according to the ventilation rate in the room.
Oxygen and Carbon Dioxide Concentration in the Air. Oxygen decrease and carbon di- Ventilated air amount is calculated on an individual basis for each premise with respect to
oxide cause stuffiness in the premises. harmful substances content or is determined by test results. If the nature and number of
Harmful Substances and Dust in the Air. High content of dust, tobacco smoke and harmful impurities (substances) cannot be identified or measured air exchange is calcu-
other substances in the air are harmful for the human organism and can cause various lated with the formula:
lung and skin diseases. L = Varea * Kp (m3/h),
Odours. Bad smell causes discomfort or irritates nervous system. where: Varea – ventilated area volume [m /h]. Kp – minimum air exchange per hour, see air
3
Air Humidity. High or low humidity causes discomfort and even may result in acute exchange table.
disease attacks. Air humidity is important also for the internal atmosphere. So, decreased
humidity in winter can cause shrinkage and cracks of wooden doors, window frames, fur- How to calculate ventilated area volume?
niture and high humidity in swimming pools and bathrooms and other humid premises Calculate the total volume of the premise in m3. Use a simple formula:
can cause excessive humidity absorption and swelling.
Air temperature. A person feels comfortable in a premise with the temperature 21- Length x Width x Height = Volume of the premises m3
23°C. Temperature variation causes the change of «comfort» well-being more or less that
influences a person’s physical and mental activity. A x B x H = V (m3)
Air Motion. Increased air speed in the premises causes the feeling of draft, and decreased
speed causes air blanketing. Being inside we feel the impact of any of these factors. Example: premise with 5 m length,
3 m width and 2.8 m height. To
Ventilation system arrangement determine the air volume required
for ventilation of this premises,
Properly arranged ventilation system is the only solution in this situation. It provides fil- calculate the volume of the room:
tered air supply in summer and filtered and warmed supply air in winter as well as extract 5 x 3 x 2.8 = 42 m3. After that
stale air removal from the premises. determine the required fan capacity
Any ventilation system must include synchronous fresh air supply and extract air exhaust using the following tables of recom-
thus ensuring the ideal air balance in the room. In case of poor or insufficient air intake mended ventilation rate.
Residential premises
Bathroom 7-9
cupied premises but its capacity is not enough for well balanced air exchange.
Shower room 7-9
Mechanical ventilation devices ensure active air exchange and can operate continu-
WC 8-10
ously or periodically depending on the ventilation need. Unlike natural ventilation,
Domestic laundry 7
mechanical ventilation operates regardless of natural conditions and indoor and out-
door temperature difference. Fan and electric motors are the basic mechanical ventila- Dressing room 1.5
tion components that provide controllable air exchange. So mechanical ventialtion is Store room 1
the best solution. Garage 4-8
Cellar 4-6
Axial fans are the wheels with blades (so called im- low noise whisper, wall clock ticking
30 standard sound level for residential premises
peller) enclosed in cylindrical casings and attached
from 23.00 till 07.00
to the hub at required angle to plane of rotation.
35 low speech
As impeller blades rotate air is trapped between
standard speech
the blades and moved further axially. Air is hardly 40 audible enough standard sound level for residential premises
moved in radial plane of rotation. Normally the axial from 07.00 till 23.00
fan blades are fixed directly to the motor shaft. 45 conventional conversation
Application: air exhaust and air supply through 50 conversation, typing
definitely audible
free openings or vents or in assembly with air ducts mounted up to 30 m horizontally with 55 Standard sound level for class A offices (EN)
low air resistance in the system. 60 office standard sound level
65 loud conversation ( > 1m)
Solutions for long air ducts noisy
70 several conversations (< 1m)
75 loud conversation (<1 m)
Turbine and scroll casing are the basic components of the centrifugal fan. The centrifugal
80 shouting, operating motorcycle with a silencer
fan impeller is a hollow cylinder with the blades inside that are fixed to the cylinder cir-
85 loud shouting, operating motorcycle with a silencer
cumference with disk plates. The hub is located inside of these plates and is designed for very noisy
90 Loud shouts, moving railway vehicle (7 m)
mounting of the impeller on the shaft. As the impeller rotates air is trapped between its
95 moving subway train (7 m)
blades, gets pressurized and moves in radial direc-
Orchestra, top noise level of the moving subway train,
tion from the center.
thunder
Under centrifugal force air is transported to the 100
Maximum permissible sound pressure for headphones
scroll casing and then to the exhaust pipe. of a personal stereo (EN)
extremely noisy
Application: air exhaust and air supply in ventila- 105 inside the airplane (before 1980s)
tion systems with extended air ductworks and high 110 helicopter
air resistance. 115 sandblaster (1 m)
120 nearly unbearable pneumatic hammer (1 m)
Fan noise level characteristics
130 pain threshold airplane at start
Noise parameters are shown in the tables that include the following characteristics:
Noise level LWA, dBA with various frequency band groups, LWA inlet, LWA outlet and
LWA surrounding.
The total sound power level at 3 m distance.
The frequency band has eight wave groups. Each group has a definite medium
frequency: 63 Hz, 125 Hz, 250 Hz, 500 Hz, 1000 Hz, 2 kHz, 4 kHz and 8 kHz.
Any noise is classified according to frequency bands and the sound energy has various
frequency groups.
The sound produced by the operating fan is spread along the air duct, get partially attenu-
ated inside the unit and penetrates through the grilles inside the premise.
Ventilation system design is based on acoustic calculation which is an integral part of any
ventilation project for any construction object.
The calculation is aimed to define the octave-frequency band in various operating points
and to determine the required sound attenuation level by comparing this spectrum with
the permissible values according to hygienic norms and standards. After selection of the
design and acoustic facilities to be used for noise level reducing the sound pressure levels
are checked for consistence with expected values in the same operating points.
What is IP?
While selecting the equipment and its location it is extremely important to ensure compliance of the protection rating to the operating conditions. Any electrical device must
meet two protection requirements:
safety for the user and operating personnel
protection of the electrical components located in the device against environmental impact.
IP rating refers to dust and moisture protection of the equipment and its electrical safety. Ingress protection rating marked as IP followed by two digits is stated in the technical
documentation and on the equipment casing. F.e. IP20 or IP65. The first digit means protection rating against contact to the electrical parts and contact to foreign objects. The
first digit designations and characteristics are listed in the table 1.
The second digit means water ingress protection rating and its designations and characteristics are listed in the table 2.
Table 1
First digit Protection characteristics Description
x No special protection Open design, no special protection against dust ingress and contact to electrical parts.
1 Protection against large objects Protected against large solid objects up to 50 mm, e.g. accidental contact with hands.
Protection against medium-sized
2 Protected against solid objects up to 12 mm, e.g. fingers contact to electrical parts.
objects
Protected against penetration of solid objects over 2.5 mm (tools and wires). Protection against accidental
3 Protection against small objects
contact to electrical parts with tools or fingers.
Protected against solid objects over 1 mm (small tools and wires). Protection against accidental contact to
4 Protection against sand penetration
electrical parts with tools or fingers.
Very limited dust ingress inside the casing that does not disturb the rated equipment operation. Total
5 Protection against dust accumulation
protection against contact to electrical parts.
6 Total dust ingress protection Total protection against dust penetration.
Table 2
Second digit Protection characteristics Description
Certification
CE mark means that the equipment is produced in compliance with Mark of conformity of the goods subject to obligatory certification
the quality and safety standards provided by EU regulations for the in DSTR system as well as technical norms and standards acting in
given product type (marked by manufacturer). Russian Federation. Confirmed by the RosTEST certificates (Moscow).
Timer
On power-off the fan continues operating within the time period set by the timer setting from 2 to 30 minutes.
Humidity sensor
Fan is equipped with an electronic processor with permanent humidity level monitoring function that prevents condensate
generation. The fan switches automatically on as the relative humidity in the premise reaches the preset threshold value
adjustable from 60 to 90 % and continues operating within 2 to 30 minutes according to the timer setting.
Motion sensor
Fan switches automatically on in case of motion detection in the premises and continues operating within the time period from 2
to 30 minutes according to the timer setting. The motion sensitivity area from 1 to 4 m and the detection angle up to 100°.
Turbo
Fan is equipped with a high-powered electric motor for higher air flow.
Press
Models are equipped with a 5-blade silent operation impeller with improved aerodynamics for higher fan pressure. Such impeller
design allows attaining previously unachievable air flow characteristics for axial fans.
12 V
Fan is equipped with a low-voltage (12 V) electric motor for safe operation in humid areas and spaces with high water ingress
probability (bathrooms, saunas etc.).
Backdraft damper
Fan is equipped with a backdraft damper for air back flow preventing. The backdraft damper is supplied as a standard with all
modifications of M, M1, D, S, M3, X, X1, and LD fans. The damper is also available as a separate equipment for KO 100, KO 125, and
KO 150 models.
VENTS Flange diameter Series Built-in options Extra Option Motor options
[mm]
230
TH – Humidity
Sensor Press
TP – Motion
12 V
Sensor
Flange
diameter [mm]
TM Series
VENTS offers a wide range of domestic fans that combine outstanding performance and reliability
with low power consumption and noise levels. These units are the perfect solution for ventilating
bathrooms, kitchens, living quarters and other premises of up to 30 m2.
VENTS fans are available in manifold modifications with various air flow, design and functioning.
Intellectual fans
VENTS iFan Wi-Fi, VENTS iFan Move Wi-Fi Series page
Air flow up to 133 m /h
3 34
• The fan has a ultra-thin casing with its • The fan is equipped with three timers:
thickness only 29 mm without a spigot. Humidity timer – setting of the fan operation for
• The fan is equipped with an integrated on/off total humidity extraction after its stabilization (30,
power slide switch for quick disconnection from 45, 60 min).
power mains. Turn-off timer – the fan continues operation for
5, 15 or 30 minutes after activation of the motion
sensor or the external switch and then reverts to
Motor the previous operation mode.
Intellectual axial fans for exhaust Switch delay timer – adjust the switch delay
ventilation with air flow
• Reliable motor on ball bearings with minimum timer to avoid the fan unnecessary switching if
energy demand up to 3.8 W.
up to 133 m3/h you use your bathroom shortly and frequently.
• The bearings are maintenance-free and are After humidity increases or after signal from the
filled with grease for the motor service life. external switch/motion sensor, the fan switches to
Application • The fan is powered through an integrated higher speed not immediately, but after the timer
pulse power supply unit with a wide power countdown (0, 2 and 5 minutes).
• Innovative exhaust fan with stylish design for supply range from 100 to 240 V and 50 to
new comfort level in shower rooms, bathrooms, 60 Hz. The fan is suitable for application in various
kitchens and other residential premises. countries and has stable operation in versatile SPEED / Fan speed adjustments
• Intellectual integrated control functions let power mains. • The fan has smooth ten step speed
control:
adjust personal settings for the most balanced • The motor is installed on a rubber anti-
microclimate. vibration connector for vibration absorbing and – for SILENT mode: from 40/33 to 83/72 m3/h (Ø
silent fan operation. 125/100 mm);
Design • The motor is equipped with overheating – for MAX mode: from 83/72 to 133/106 m3/h (Ø
protection. 125/100 mm);
• Unique motor design and aerodynamic
impeller profile ensure the minimum noise
level – only 21 dBA whereas the air flow remains 24 HOURS / Permanent ventilation
Modifications and Options
high.
• Permanent low-speed operation
Basic model with intellectual mode ensures continuous minimum
humidity control. air exchange in the room with air flow 40/33 m3/h
Model with intellectual (Ø 125/100 mm). After humidity change the fan
humidity control and is switched to MAX mode (by default) or SILENT
extra motion sensor mode. The fan is switched to SILENT mode after
control. signal from the motion sensor or external switch.
Dimensions [mm]
Model
ØD B H L L1
iFan
100/125 152 206 57 29
iFan Move
Technical data
24 HOURS 33 17 33 -
100 SILENT 72 22 72 33...72
iFan
iFan Move MAX 106 31 82 72...106
24 HOURS 40 17 40 -
125 SILENT 83 21 83 40...83
MAX 133 32 97 83...133
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.
READY
Series Automatic interval ventilation
Automatic interval ventilation (function is
iFan Wi-Fi only available when the 24 hours mode is
CONTROL
iFan Move Wi-Fi deactivated). This mode allows ventilating the room
every 12 hours for 30 minutes at the set speed.
Silent mode
The fan runs at Silent speed. The speed
can be adjusted in the range from 30 % to
100 % of the fan maximum performance.
Max (Boost Mode)
• The fan has an ultra-thin casing with a thickness
of only 29 mm without a spigot. The fan runs at Max speed. The speed can
be adjusted in the range from 30 % to 100
• The fan is equipped with an integrated on/off
% of the fan maximum performance.
power slide switch for quick disconnection from
power mains. HUMIDITY SENSOR / Humidity con-
trol adjustment
The fan has an integrated intelligent hu-
Motor midity sensor with the following operation modes:
Manual mode allows setting the humidity thresh-
Intellectual axial fan with an integrated • Reliable motor on ball bearings with minimum
old in range from 40 % to 80 %. If this threshold is
Wi-Fi module for exhaust ventilation with energy demand up to 6 W.
exceeded, the fan turns on or switches to higher
air flow up to • The bearings are maintenance-free and are filled speed.
133 m3/h with grease for the whole motor service life.
Auto – intelligent humidity control. This mode pro-
• The fan is powered through an integrated pulse vides for humidity threshold change and fan speed
power supply unit with a wide power supply range selection in automatic mode. The fan independent-
from 100 to 240 V and 50 to 60 Hz. The fan is suita-
17 1.6 133 ble for application in various countries and has sta-
ly selects the optimum humidity threshold for the
dBA W m3/h room in which it is installed. Fan operation algorithm
ble operation in versatile power mains. is selected based on analysing the statistical data of
• The motor is installed on a rubber anti-vibration indoor humidity level.
connector for vibration absorbing and silent fan op- Automatic operation based on temperature sen-
eration. sor. If the air temperature exceeds the set point, the
• The motor is equipped with overheating protec- fan will switch to Max speed and will return to the
Application tion. previous mode only after indoor temperature drops
by 4 °C below the set point.
• Innovative exhaust fan with stylish design for
MOTION SENSOR / Motion sensor (for
new comfort level in shower rooms, bathrooms,
Modifications the iFan Move Wi-Fi model)
kitchens and other residential premises.
READY
READY
When the motion sensor is activated, the
• Intellectual integrated control functions allow
READY
microclimate. CONTROL
CONTROL
switch to Silent speed. Once there is no motion de-
tected, and after turn-off delay time the fan will
Model with intellectual humidity control and auto-
switch to standby mode.
Design matic heat distribution.
READY
READY
•
READY
Specially designed motor and aerodynamically
optimized impeller shape provide super silent oper- CONTROL
CONTROL
CONTROL
ation at only 17 dBA, which is combined with high
air performance. Model with intellectual humidity control, automatic
heat distribution and extra motion sensor control.
Operation modes
The operating mode for the iFan Wi-Fi fan can be se-
lected using an application for Android or iOS.
24 HOURS / Non-stop ventilation
Silent – permanent low-speed operation
mode. If the humidity changes, the fan
switches to a higher speed (MAX mode). The fan is
• Front panel 3D design and rich colour palette of switched to Silent mode after signal from the motion
replaceable decorative panels give zest to the most sensor or external switch.
refined interior. Do not disturb – the function is only available when
• Due to replaceable spigots the fan is suitable for the 24 hours mode is activated. This function allows
mounting with Ø100 or Ø125 mm air ducts. for setting the time interval so that the fan will not re-
spond to sensors or switch actuation, and will oper-
ate at minimum speed (Silent).
TIMER/Turn-on and turn-off delay timers
Turn-on delay timer allows to delay
switching to a higher speed by 2 or 5 min-
utes after sensor activation.
Turn-off delay timer is designed to prolong the fan
operation for 5, 15, 30 or 60 minutes in the mode
• The motor-impeller block is easy to remove with- caused by sensor activation or Boost mode activa-
out special tools which grants easy servicing. tion.
30
25
20
H
15
10
B
5
0
0 20 40 60 80 100 120 140
Air flow [m3/h]
Technical data
iFan Wi-Fi
Model
iFan Move Wi-Fi
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.
Axial fans
VENTS Quiet Series page
Air flow – up to 370 m /h 3 38
Axial fans
VENTS Quiet DC Series page
Air flow – up to 101 m3/h 40
Axial fans
VENTS Quiet-Style page
Air flow – up to 90 m /h
3
42
Axial fans
VENTS Quiet-S page
Air flow – up to 99 m /h
3
44
Axial fans
VENTS Quiet-Disc page
Air flow – up to 370 m /h 3
46
Axial fans
VENTS Quiet Duo Series page
Air flow – up to 170 m /h 3
48
Axial fans
VENTS Quiet-dMEV DC Series page
Air flow – up to 83 m3/h 50
Axial fans
VENTS Silenta-M Series page
Air flow up to 242 m /h
3
52
Axial fans
VENTS Silenta-S Series page
Air flow up to 240 m /h
3
54
Axial fans
VENTS Style Duo Series page
Air flow up to 90 m /h 3 58
Colour modifications
Quiet 100/125/150 Quiet 100/125/150 Quiet 100/125/150 Quiet 100/125/150 Quiet 100/125/150
Red RAL 3013 Vintage Aluminum Lacquer Chrome Black Sapphire
Aerodynamic characteristics
45 120
30 50 80
25
40
60
20
30
15 40
20
10
20
5 10
Air flow [m3/h]
0 0
0
0 10 20 30 40 50 60 70 80 90 100 0 50 100 150 200 250 300 350 400
0 20 40 60 80 100 120 140 160 180 200
Air flow [m3/h] Air flow [m3/h] Air flow [m3/h]
Overall dimensions
Dimensions [mm]
Model
ØD B H L L1
VENTS Quiet 100 99 158 136 81 26
VENTS Quiet 125 123.5 182 158 91 27
VENTS Quiet 150
147.5 214 190 111 32
VENTS Quiet Extra 150
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.
• Low energy demand up to 3.5 W due to a new • The fan is turned off by default. The fan starts
Series high-efficient motor. operating at the low speed when the switch is
closed and switches to the high speed when the
• Maintenance-free bearings contain enough humidity or motion sensor is activated.
grease for 40 000 hrs non-stop operation.
• Motor equipped with electric overheating pro- Control
tection. Manual control:
Modifications and Options • Manual operation with a room light switch.
The switch is not included in the delivery set.
Quiet DC T: modification with a turn-
off delay timer regulated from 2 up to 30 • Operation with the integrated pull cord switch
V. Not applied in case of ceiling mounting.
minutes. All the Quiet DC fans have this
timer by default. Automatic control:
Quiet DC TH: modification • With the electronic control unit BU-1-60 (see
with a turn-off delay timer Electrical Accessories). The control unit is supplied
D
C E
regulated from 2 up to 30 min- separately.
B
utes and a humidity sensor with an adjustable • With the turn-off delay timer T. The built-in
A
threshold from 60 to 90 %. turn-off delay timer enables operation of the fan
Quiet DC VT: modification within 2 up to 30 minutes after turning the fan off
Updated version of low-noise axial with a pull cord switch and a with a switch.
fans with DC motors for low energy turn-off delay timer regulated • With the humidity sensor and timer TH. If the
consumption from 2 up to 30 minutes. indoor humidity exceeds the set humidity point
Quiet DC VTH: adjustable from 60 to 90 %, the fan switches au-
Application modification with tomatically to the high speed and operates until
a pull cord switch, the humidity level drops below the set point. After
• Innovative extract fan with stylish design for a turn-off delay timer regulated from 2 up to 30 that the fan continues operating according to the
enhanced comfort level in shower rooms, bath- minutes and a humidity sensor with an adjustable timer settings and turns either to the low speed
rooms, kitchens and other residential premises. threshold from 60 to 90 %. or turns off.
• Maximum air flow combined with low noise Quiet DC TP: modification • With the motion sensor and the timer TP. If the
level provide the ideal microclimate. with a turn-off delay timer motion sensor detects motion in the reach area up
to 4 m with a viewing angle up to 100°, the fan
• Mounting into ventilation shafts or connec- regulated from 2 up to 30 min-
turns on and operates from 2 to 30 minutes ac-
tion to Ø 100 mm air ducts. utes and a motion sensor with reach distance up
to 4 m and viewing angle up to 100°. cording to the timer settings.
• Two-speed operation modes with max. air
flow 100 m3/h. Operation modes of Quiet 100 DC Mounting features
Design
fan with an integrated turn-off • Installation directly inside a ventilation shaft.
delay timer, humidity sensor • Flexible air ducts may be used in case of re-
• The casing and the impeller are made of high- and motion sensor. mote location of the ventilation shaft. The air duct
quality and durable UV-resistant plastic. is connected to the exhaust spigot with a fixing
Operation mode selection and setup for Quiet 100
• The specially designed aerodynamic profile of DC models with modifications T, TH, VT, VTH, TP is clamp.
the mixed-flow impeller provides high air flow and
pressure combined with low-noise operation.
performed by setting the DIP switch to a respec- • Wall mounting with screws.
tive position.
• Suitable for ceiling mounting.
• A shortened spigot for mounting into a venti- Mode 1 (single-speed mode)
lation shaft or direct connection to Ø 100 mm air
duct. • The fan is turned off by default. The fan starts
operating at the low speed when the switch is
• The fan is equipped with a specially designed closed or one of the sensors is activated.
backdraft damper to prevent back flow and heat
Mode 2 (single-speed mode)
losses during the fan standby.
• The fan exhaust spigot incorporates special- • The fan is turned off by default. The fan starts
operating at the high speed when the switch is
ly designed air rectifiers to reduce air turbulance,
closed or one of the sensors is activated.
noise level and boost air pressure.
Mode 3 (two-speed mode)
• High ingress protection rating makes the fan
• The fan operates at the low speed by default.
the ideal solution for ventilation of a bathroom.
The fan switches to the high speed when the
The electronic components are protected with
switch is closed or the sensors are activated.
tight covers.
Colour modifications
Quiet 100 DC Quiet 100 DC Quiet 100 DC Quiet 100 DC Quiet 100 DC
Red RAL 3013 Vintage Aluminum Lacquer Chrome Black Sapphire
Aerodynamic characteristics
70
50
40
30
max
20
min
10
0
0 20 40 60 80 100
Air flow [m3/h]
Overall dimensions
Dimensions [mm]
Model
ØD B H L L1
VENTS Quiet DC 99 158 136 81 26
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.
Colour modifications
Quiet-Style A
(with a decorative aluminium
surface-mounted panel)
Sound Pressure
Frequency Power Current Maximum air Weight,
Model Voltage [V] Level at 3 m IP
[Hz] Consumption [W] [A] capacity [m3/h] kg
[dBA]
VENTS Quiet-Style 100 50 220-240
VENTS Quiet-Style 7.5 0.050 90 26 0.66 IP45
60 220
100 (220 V/60 Hz)
Aerodynamic characteristics
30
20
15
10
0
0 10 20 30 40 50 60 70 80 90 100
Air flow [m3/h]
Overall dimensions
Dimensions [mm]
Model
ØD B L L1
VENTS Quiet-Style 100 99 200 130 49
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.
Quiet-S VT – modification
with pull-cord switch and
off-delay timer with operating
time from 2 to 30 min.
Quiet-S VTH –
modification with
The delivery set includes three pull-cord switch, off-
decorative panels in white, blue and delay timer with operating time from 2 to 3 0 min
green. and humidity sensor with threshold from 60 to
90 %.
Quiet-S TP – modification
with off-delay timer with
operating time from 2 to
30 min and motion sensor; reach distance up to 4
m, viewing angle up to 100°.
Sound Pressure
Frequency Power Current Maximum air Weight,
Model Voltage [V] Level at 3 m IP
[Hz] Consumption [W] [A] capacity [m3/h] kg
[dBA]
VENTS Quiet-S 100 50 220-240
VENTS Quiet-S 100 7.5 0.049 99 24 0.58 IP45
60 220
(220 V/60 Hz)
Aerodynamic characteristics
45
35
30
25
20
15
10
0
0 10 20 30 40 50 60 70 80 90 100
Air flow [m3/h]
Overall dimensions
Dimensions [mm]
Model
ØD B L L1
VENTS Quiet-S 100 99 175 123 42
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.
VENTS Quiet-Disc • Motor on special anti-vibration dampers for vi- Mode 3 (two-speed mode)
bration absorption and silent operation.
• The fan operates at the 1st speed by default.
Series • Motor equipped with overheating protection. The fan switches to the 2nd speed when the
switch is closed or the sensors are activated.
• The VENTS Quiet-Disc 150 is supplied with a
two-speed motor. The VENTS Quiet-Disc Extra 150 Mode 4 (two-speed mode)
is supplied with a two-speed high powered mo-
tor.
• The fan is turned off by default. The fan starts
operating at the 1st speed when the switch is
closed and switches to the 2nd speed when the
Modifications and Options humidity sensor is activated.
Quiet-Disc Extra – high-powered mo- Mode 5 (two-speed mode)
tor. • The fan is turned off by default. The fan starts
operating at the 1st speed when the switch is
closed or when the humidity sensor is activated.
Quiet-Disc T – turn-off delay timer If during the operation at the 1st speed the sec-
modification with operating time from ond even takes place. i.e. the switch is closed or
2 to 30 min. the humidity sensor is activated, the fan switches
to the 2nd speed.
Intellectual axial low-noise and energy- Quiet-Disc TH – turn-off de-
saving fan for exhaust ventilation lay timer modification with Control
with air flow up to 370 m3/h operating time from 2 to 30
min and a humidity sensor with threshold from 60 Manual control:
Application to 90 %. • Manual control with a room light switch. The
switch is not included in the delivery set.
• Innovative exhaust fan with stylish design for Quiet-Disc V – pull-cord switch mod-
new comfort level in shower rooms, bathrooms, ification. • The fan is controlled by the built-in pull cord
kitchens and other residential premises. switch V. Not applied in case of ceiling mounting.
• Maximum air flow combined with low noise Quiet-Disc VT – modification • Speed control is possible through a thyris-
level provide the ideal microclimate. tor speed controller or through a P2-1-300 speed
with a pull-cord switch and
switch (only for VENTS Quiet-Disc 150 models), see
• Mounting into ventilation shafts or connec- a turn-off delay timer with
Electrical Accessories. Several fans may be con-
tion to Ø 100, 125, 150 mm. operating time from 2 to 30 min.
nected to the same controller. Speed controllers
Design Quiet-Disc VTH – can not be connected to the fans with the T, TH, TP,
modification with a VT, VTH modifications.
• Casing and impeller made of high-quality and pull-cord switch, a
Automatic control:
durable UV-resistant plastic. turn-off delay timer with operating time from 2 to
• Specially designed impeller aerodynamic pro- 30 min and a humidity sensor with threshold from • By the electronic control unit BU-1-60 (see
file provides high air flow and low noise. 60 to 90 %. Electrical Accessories). The control unit is supplied
separately.
• The compact design enables wall and ceiling Quiet-Disc TP – modification
mounting. with a turn-off delay timer • By the timer T (the built-in turn-off delay timer
with operating time from 2 to enables the fan operation within 2 to 30 minutes
• The shortened spigot for mounting into a 30 min and a motion sensor; reach distance up to after the fan switching off ).
ventilation shaft or connection to Ø 100, 125,
150 mm air ducts.
4 m, viewing angle up to 100°. • By the humidity sensor and timer TH (if the
* The VENTS Quiet-Disc 150 models with the T/TP/ humidity level in the room exceeds the sensor
• The fan is equipped with a specially designed VT/VTH modifications are additionaly supplied threshold within 60-90 % the fan switches auto-
back valve to prevent back flow and heat losses
with a turn-on delay timer adjustable from 0 up matically on and operates until the humidity level
during the fan standby.
to 2 minutes. drops to the standard level, after that the fan con-
• The fan exhaust spigot incorporates specially tinues operating within the set time period and
designed air rectifiers to reduce air turbulence, in- shuts down).
crease air pressure and lower noise level.
VENTS Quiet-Disc 150 and VENTS Qui-
et-Disc Extra 150 operation modes • By the motion sensor and timer TP (if motion
• High ingress protection rating makes the
Operation modes of the fans models VENTS Qui- is detected in the reach area, the fan is switched
fan the ideal solution for ventilation of a bath- automatically and operates within the set time
et-Disc 150 and VENTS Quiet-Disc Extra 150 with
room. The electronic components are protected period from 2 to 30 min). Reach distance up to
modifications T, TH, VT, VTH, TP are selected by set-
with tight covers. The VENTS Quiet-Disc 150 and 4 m, the max. viewing angle 100°.
ting the DIP switch into the required position.
VENTS Quiet-Disc Extra 150 models are addition-
aly equipped with a special vibration absorbing Mounting features
sealer along the fan countour. Mode 1 (single-speed mode)
• The fan is turned off by default. The fan starts
• Installation directly inside a ventilation shaft.
operating at the 1st speed when the switch is • Flexible air ducts may be used in case of re-
Motor closed or one of the sensors is activated. mote location of the ventilation shaft. Connection
of the air duct to the exhaust flange with a clamp.
• Low energy demand from 7.5 W due to new Mode 2 (single-speed mode)
high-efficient motor.
• The fan is turned off by default. The fan starts • Wall mounting with screws.
• Maintenance-free bearings contain enough operating at the 2nd speed when the switch is • Suitable for ceiling mounting.
grease for 40 000 hrs non-stop operation. closed or the sensors are activated.
Colour modifications
Quiet-Disc 100/125/150 Quiet-Disc 100/125/150 Quiet-Disc 100/125/150 Quiet-Disc 100/125/150 Quiet-Disc 100/125/150
Red Vintage Aluminum Lacquer Chrome Black Sapphire
Aerodynamic characteristics
45 120
30 50 80
25
40
60
20
30
15 40
20
10
20
5 10
0 0
0
0 10 20 30 40 50 60 70 80 90 100 0 50 100 150 200 250 300 350 400
0 20 40 60 80 100 120 140 160 180 200
Air flow [m3/h] Air flow [m3/h] Air flow [m3/h]
Overall dimensions
Dimensions [mm]
Model
ØD B H L L1
VENTS Quiet-Disc 100 99 158 136 81 26
VENTS Quiet-Disc 125 123.5 182 158 91 27
VENTS Quiet-Disc 150
147.5 214 190 111 32
VENTS Quiet-Disc Extra 150
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.
VENTS Quiet Duo • The fan exhaust spigot incorporates special- Control
ly designed air rectifiers to reduce air turbulance,
Manual control:
Series noise level and boost air pressure.
• High ingress protection rating makes the fan • Manual control with a room light switch. The
the ideal solution for bathroom ventilation. The switch is not included in the delivery set.
electronic components are protected with tight The fan is controlled by the built-in pull cord
covers. switch V. Not applied in case of ceiling moun-
ting.
Motor Speed control with the thyristor speed controller
or speed switch P2-1-300, see Electrical Accesso-
• Low energy demand from 4 W due to a new ries. Several fans may be connected to the same
two-speed high-efficient motor. controller. Speed controllers are not compatible
• Maintenance-free bearings contain enough with the fans with T, TH modification.
grease for 40 000 hrs non-stop operation. Automatic control:
• Motor on special anti-vibration dampers for vi- • By the electronic control unit BU-1-60 (see
bration absorbing and silent operation. Electrical Accessories). The control unit is supplied
• Motor equipped with overheating protection. separately.
• Two-speed ventilation up to 170 m3/h. • Flexible air ducts may be used in case of remote
Quiet Duo TH: off-delay tim- location of the ventilation shaft. The air duct is con-
• Permanent low-speed operation mode en-
er modification with a turn-off nected to the exhaust spigot with a fixing clamp.
sures continuous minimum air exchange in the
room. delay from 2 to 30 min and hu- • Wall mounting with screws.
midity sensor with an adjustable thres-hold from
• Mounting into ventilation shafts or connection 60 to 90 %.
to Ø 100 mm and 125 mm air ducts.
* VENTS Quiet 100 Duo and VENTS Quiet 125 Duo
with modifications T and TH are supplied with an
Design integrated switch delay timer to avoid the fan un-
necessary switching if you use your bathroom
• The casing and the impeller are made of high- shortly and frequently. After humidity increases or
quality and durable UV-resistant plastic.
after signalling from the external switch, the fan
• The specially designed aerodynamic profile switches to higher speed not immediately, but af-
of the mixed-flow impeller provides high air flow ter the set timer countdown (1 min).
combined with low-noise operation.
• The compact design enables wall and ceiling Operation modes of the fans with
installation. modifications T, TH:
• A shortened spigot for mounting into a venti- The fan operates at the low speed by default. The
lation shaft or direct connection to Ø 100 mm and fan switches to the high speed when the switch is
125 mm air duct. closed or the humidity sensor is activated.
• The fan is equipped with a specially designed
back valve to prevent back flow and heat losses
during the fan standby.
Colour modifications
Quiet 100/125 Duo Quiet 100/125 Duo Quiet 100/125 Duo Quiet 100/125 Duo Quiet 100/125 Duo
Red RAL 3013 Vintage Aluminum Lacquer Chrome Black sapphire
50 60
45
55 VENTS Quiet 125 Duo
VENTS Quiet 100 Duo
50
40
45
35
40
30 35
25 30
max
max
25
20 min
min 20
15
15
10
10
5 5
0 0
0 10 20 30 40 50 60 70 80 90 0 25 50 75 100 125 150 175
Air flow [m3/h] Air flow [m3/h]
Technical data
max 4 0.029 60 22
VENTS Quiet 100 Duo 50/60 220-240 0.55 IP45
min 7.5 0.052 90 25
max 9.5 0.065 145 28
VENTS Quiet 125 Duo 50/60 220-240 0.78 IP45
min 13.5 0.09 170 32
Overall dimensions
Overall dimensions [mm]
Model
ØD B H L L1
VENTS Quiet 100 Duo 99 158 136 81 26
VENTS Quiet 125 Duo 123.5 182 158 91 27
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.
• High-efficient direct current motor with low • The fan runs with the Trickle speed by default.
VENTS Quiet-dMEV DC energy consumption of maximum 3.4 W. In case of actuation of the switch the turn-on delay
timer countdown starts and then the fan starts to
• Maintenance-free bearings are greased for run with the Boost speed. After turning the fan off
40 000 hrs of non-stop operation.
the turn-off delay timer is activated.
• The motor is equipped with overheating pro-
Operation mode 3
tection.
• The fan runs with the Trickle speed by default.
Modifications and Options In case of actuation of the humidity sensor the fan
goes to the Boost speed mode. After decrease of
Quiet-dMEV DC 12: modification with the indoor humidity below the set threshold the
safe low-voltage 12 V ac motor. turn-off delay timer is activated.
Control
Quiet-dMEV DC T: timer modification
with a fixed turn-on delay of 60 s and a Manual control:
C
D E
regulated turn-off delay from 2 up to 30 • Manual operation with a room light switch.
minutes. The light switch is not included in the delivery set.
B
Colour modifications
Quiet-dMEV 100 DC Quiet-dMEV 100 DC Quiet-dMEV 100 DC Quiet-dMEV 100 DC Quiet-dMEV 100 DC
Red Vintage Aluminum Lacquer Chrome Black Sapphire
60
50
40
30
20
10
0
0 10 20 30 40 50 60 70 80 90
Air flow [m3/h]
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards
• The casing and the impeller are made of high- • The fan is controlled by a room light switch. It
quality durable ABS plastic, UV resistant. is not included in the delivery package.
• The intellectual impeller design makes the fan • The fan is controlled by the built-in pull cord
efficiency high and the service life long. switch V. Not applied in case of ceiling mounting.
• The fan and motor are specially designed for • Speed control is possible through a thyristor
silent operation. speed controller (see Electrical Accessories).
Several fans may connected to the same controller.
• Protection rating IP34. Speed controllers can not be connected to the
fans with T, TH, TP, VT, VTH modification.
Motor
Automatic:
• Reliable motor with the minimum power
• By the electronic control unit BU-1-60 (see
consumption 7 W (for 100 mm diameter).
Electrical Accessories). The control unit is supplied
• Designed for continuous operation and separately.
requires no maintenance.
• By the timer T (the built-in turn-off delay timer
• Equipped with overheating protection. enables the fan operation within 2 to 30 minutes
after the fan switching off ).
Low-noise and low-watt axial fans for Modifications and Options • By the humidity sensor and timer TH (if the
exhaust ventilation with air flow up to Silenta-M K – fan is equipped with humidity level in the room exceeds the sensor
242 m3/h a backdraft damper for back flow threshold adjustable value within 60-90 % the fan
preventing. switches automatically on and operates until the
humidity level drops to the standard level, after
Silenta-M L – the motor is equipped that the fan continues operating within the time
Application with ball bearings for long service period according to the timer setting, then shuts
• Continuous or periodic exhaust ventilation life (appr. 40 thousand hours) and down).
of bathroom, showers, kitchens and other utility fan mounting at any angle. The bearings are
spaces. maintenance-free and contain enough grease for • By the motion sensor and the timer TP (in case
the entire operating period. of motion detection the fan switches automatically
• Ventilation of premises with high noise level Silenta-MT – equipped with a
on and operates within the set time period from
limitations. 2 to 30 minutes. The motion sensitivity area is up
regulated timer with the operating to 4 meters and the maximum detection angle is
• Ventilation shaft mounting or duct connec-
time from 2 to 30 minutes. 100°).
tion.
Silenta-MTH – equipped
• Compatible with Ø 100, 125 and 150 mm air with a timer with the Mounting features
ducts.
operating time from 2 to 30
minutes and a humidity sensor with the threshold
• The fan is mounted directly into the ventilation
shaft.
value from 60 to 90 %.
Silenta-MV – equipped with a pull
• Flexible duct application is recommended in
case of remote location of the ventilation shaft.
cord switch. The air duct is connected to the fan exhaust flange
through a clamp.
Silenta-MVT – equipped • Fixed to wall by self-tapping screws.
with a pull cord switch and
a regulated timer with the • Suitable for ceiling mounting.
operating time adjustable from 2 to 30 minutes.
Silenta-MVTH –
equipped with a
pull cord switch,
regulated timer with the operating time adjustable
from 2 to 30 minutes and a humidity sensor with
the operating threshold range from 60 to 90 %.
Silenta-MTP – equipped
with a regulated timer and
a motion sensor with the
sensitivity area from 1 to 4 m and the detection
angle up to 100°.
Accessories
Backdraft
Air ducts Grilles and hoods damper Speed controllers Clamps
Technical data
Sound Pressure
Frequency Power Current Maximum air
Model Voltage [V] Level at 3 m Weight, kg
[Hz] Consumption [W] [A] capacity [m3/h]
[dBA]
Overall dimensions
Dimensions [mm]
Model
ØD B H L L1
VENTS 100 Silenta-M 100 159 135 89 23
VENTS 125 Silenta-M 125 180 150 94 25
VENTS 150 Silenta-M 150 206 182 106 26
Mounting example
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.
• The casing and the impeller are made of high- • The fan is controlled by a room light switch. It
quality durable ABS plastic, UV resistant. is not included in the delivery package.
• The intellectual impeller design makes the fan • The fan is controlled by the built-in pull cord
efficiency high and the service life long. switch V. Not applied in case of ceiling mounting.
• The fan and motor are specially designed for • Speed control is possible through a thyristor
silent operation. speed controller (see Electrical Accessories).
Several fans may connected to the same controller.
• Insect screen. Speed controllers can not be connected to the
• Protection rating IP34. fans with T, TH, TP, VT, VTH modification.
Automatic:
Motor
• By the electronic control unit BU-1-60 (see
Electrical Accessories). The control unit is supplied
• Reliable motor with the minimum power separately.
consumption 7 W (for 100 mm diameter).
• Designed for continuous operation and • By the timer T (the built-in turn-off delay timer
requires no maintenance. enables the fan operation within 2 to 30 minutes
after the fan switching off ).
• Equipped with overheating protection.
Low noise and low watt axial fans for • By the humidity sensor and timer TH (if the
humidity level in the room exceeds the sensor
exhaust ventilation with the capacity Modifications and Options threshold adjustable value within 60-90 % the fan
up to 240 m3/h Silenta-S K – fan is equipped with switches automatically on and operates until the
a backdraft damper for back flow humidity level drops to the standard level, after
preventing. that the fan continues operating within the time
Application period according to the timer setting, then shuts
Silenta-S L – The motor is equipped
down).
• Continuous or periodic exhaust ventilation with ball bearings for long service
of bathroom, showers, kitchens and other utility life (appr. 40 thousand hours) and
spaces.
Mounting features
fan mounting at any angle. The bearings are
• Ventilation of premises with high noise level maintenance-free and contain enough grease for • The fan is mounted directly into the ventilation
the entire operating period. shaft.
limitations.
• Ventilation shaft mounting or duct connec- Silenta-ST – equipped with a regulated • Flexible duct application is recommended in
timer with the operating time from 2 to case of remote location of the ventilation shaft.
tion.
30 minutes. The air duct is connected to the fan exhaust flange
• Compatible with Ø 100, 125 and 150 mm air Silenta-STH – equipped with
through a clamp.
ducts.
a timer with the operating • Fixed to wall by self-tapping screws.
time from 2 to 30 minutes and • Suitable for ceiling mounting.
a humidity sensor with the threshold value from
60 to 90 %.
Silenta-SV – equipped with a pull cord
switch.
Silenta-SVT – equipped
with a pull cord switch and
a regulated timer with the
operating time adjustable from 2 to 30 minutes.
Silenta-SVTH –
equipped with a
pull cord switch,
regulated timer with the operating time adjustable
from 2 to 30 minutes and a humidity sensor with
the operating threshold range from 60 to 90 %.
Accessories
Backdraft
Air ducts Grilles and hoods damper Speed controllers Clamps
Technical data
Sound Pressure
Frequency Power Current Maximum air
Model Voltage [V] Level at 3 m Weight, kg
[Hz] Consumption [W] [A] capacity [m3/h]
[dBA]
Overall dimensions
Dimensions [mm]
Model
ØD B H L L1
VENTS 100 Silenta-S 100 150 120 108 12
VENTS 125 Silenta-S 125 176 140 114 13
VENTS 150 Silenta-S 150 205 165 132 14
Mounting example
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.
Design
• The casing and the impeller are made of high-
quality and durable UV-resistant plastic.
Accessories
Backdraft
Air ducts Grilles and hoods dampers Speed controllers Clamps
35 e
c
30
25
20
Ød
15
10
b
5
0
0 10 20 30 40 50 60 70 80 90 100
Air flow [m3/h] a
Mounting example
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.
Control
Manual:
• The fan is controlled by a room light switch (not
included in the delivery set).
Automatic:
• By the T timer. The built-in timer switches the
fan to high speed in 60 seconds after the external
switch closes and allows it to operate at high speed
for 2-30 minutes after the external switch opens.
Motor Then the fan returns to the previous operation mode.
When the interval timer is activated, the fan will also
• The motor is equipped with a new energy ef- turn on every 6, 12 or 24 hours depending on the se-
ficient two-speed ball bearing motor with low en- lected interval and operate at the first speed for the
ergy demand. time specified by the turn-off delay timer (from 2 to
Innovative two-speed
domestic extract fan • Maintenance-free bearings contain enough 30 minutes).
grease for 40 000 hrs of non-stop operation.
with automatic shutters, • By the humidity sensor and the TH timer. If the hu-
low-noise operation and • Motor on special anti-vibration dampers for vi- midity level in the room exceeds the sensor threshold
bration absorbing and silent operation. (60-90 %), the fan will automatically switch to high
low energy consumption speed and continue running from 2 to 30 minutes
with the capacity of up to 90 m3/h • Motor equipped with electric overheating pro-
(specified by the timer) after the humidity returns to
tection.
normal levels. When the fan is turned on using the
room light switch, it will turn on at low speed with
Modifications and options a time delay of 60 s, and after opening the switch it
Application
will continue to operate for the time specified by the
• Innovative extract fan with stylish design for VENTS 100 Style Duo T: equipped turn-off delay timer (from 2 to 30 minutes).
enhanced comfort level in shower rooms, bath- with a non-adjustable turn-on delay
rooms, kitchens, and other residential premises. timer (60 s), an adjustable turn-off delay
timer (from 2 to 30 minutes), and an interval timer
• Maximum air flow combined with low noise (from 6 to 24 hours).
level provide the ideal microclimate.
• Intermittent or continuous ventilation of bath-
rooms, shower rooms, kitchens and other utility
spaces.
• Mounting into ventilation shafts or connec-
tion to Ø 100 mm air ducts.
Design
• The casing and the impeller are made of high-
quality and durable UV-resistant plastic.
• Due to its modern look the fan is compatible
with any interior design.
• Specially designed impeller aerodynamic pro-
file provides high air flow and low noise.
• A shortened spigot for mounting into a venti-
lation shaft or direct connection to Ø 100 mm air
ducts.
• The fan exhaust spigot incorporates special-
ly designed air rectifiers to reduce air turbulence,
noise level and boost air pressure.
• High ingress protection rating makes the
fan an ideal bathroom ventilation solution. The
electronic components are protected with tight
covers.
Accessories
Backdraft
Air ducts Grilles and hoods dampers Speed controllers Clamps
Design features
Aerodynamic
mixed-flow impeller
Ventilation
unit
Casing
with controls
Front panel
30
25
max
Ød
20
15
min
b
10
0
0 10 20 30 40 50 60 70 80 90
a
Air flow [m3/h]
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.
Solid L: modification with a ball bearing • Control with the timer T1. After turning of the
external switch the turn-on delay timer is activat-
motor for long service life (around 40 000
ed for from 10 seconds to 2 minutes. The fan re-
operating hours). Installation at any an-
mains turned off. After the fan is turned off with
gle is possible. The ball bearings require no main-
the external switch the fan keeps running within 2
tenance and are greased for the entire service life.
up to 30 minutes according to the settings of the
Solid T: modification with a regulated turn-off delay timer.
turn-off delay timer.
• Control with the timer and humidity sen-
Low-noise and low-power sor TH. If the indoor humidity exceeds the set hu-
extract axial fan with air flow Solid T1: modification with a turn-on midity point adjustable from 60 to 90 %, the fan
up to 85 m3/h delay timer regulated from 10 seconds to switches automatically on and runs until the in-
2 minutes and a turn-off delay timer reg- door humidity drops below the set humidity
ulated from 2 up to 30 minutes. point. After that the fan continues running accord-
Application ing to the timer settings and turns off.
Solid TH: modification with a
• Permanent or intermittent extract ventilation turn-off delay timer regulated
of shower rooms, bathrooms, kitchens and other from 2 up to 30 minutes and a Mounting features
residential premises humidity sensor regulated from 60 % up to 90 %.
• Ventilation of premises with high requi Solid V: modification with a pull-cord
• Direct installation inside a ventilation shaft.
rements to noise level. switch. • Flexible air ducts may be used in case of re-
mote location of the ventilation shaft. The air duct
• Mounting into ventilation shafts or connec- is connected to the exhaust spigot with a fixing
tion to Ø 100 mm air ducts. clamp.
Solid VT: modification with a
pull-cord switch and a turn-off • Wall mounting with screws.
Design delay timer regulated from 2
up to 30 minutes. • Suitable for ceiling mounting.
• Modern design and aesthetic look.
Solid VTH: modi-
• The casing, the impeller and the front pa-
fication with a pull
nel are made of high-quality and durable UV-
cord switch, turn-
resistant plastic.
off delay timer regulated from 2 up to 30 mi-nutes
• The specially designed aerodynamic profile of and a humidity sensor regulated from 60 % up to
the mixed-flow impeller provides high air flow and 90 %.
pressure combined with low-noise operation.
Colour modifications
Solid Solid Red Solid Black Solid Dim Solid Glass Solid Solid Solid Alu Solid Chrome
Front panel Front panel Sapphire white matte front panel made Glass Red Glass Black front panel front panel with a
in white, in red Front panel front panel of white front panel made front pane made of with a stainless polished stainless
basic model in black natural glass of red natural glass black natural glass steel trim steel trim
Accessories
Backdraft
Air ducts Grilles and hoods dampers Speedcontrollers Clamps
25 30
20 25
20
15
15
10
10
5 5
0 0
0 10 20 30 40 50 60 70 80 90 0 20 40 60 80 100 120 140 160
Air flow [m3/h] Air flow [m3/h]
Overall dimensions
Dimensions [mm]
Model
ØD B L L1
VENTS 100 Solid 99.0 160 79 38
VENTS 125 Solid 123.5 180 85 38
Technical data
Mounting example
Certificates
IP44 The fans meet the applicable safety and electromagnetic compatibility standards.
Accessories
Backdraft
Air ducts Grilles and hoods dampers Speed controllers Clamps
Model
40 VENTS 100 Wave ØD B L L1
VENTS 100 Wave 99 160 79 38
35
30
25
20
15
10
0
0 10 20 30 40 50 60 70 80 90
Air flow [m3/h]
Technical data
Power Maximum Sound
Frequency Voltage Current RPM Weight
Model consumption air flow pressure Level IP
[Hz] [V] [A] [min-1] [kg]
[W] [m3/h] at 3 m [dBA]
Mounting example
Certificates
IP44 The fans meet the applicable safety and electromagnetic compatibility standards.
Motor
• Reliable motor with low energy demand.
• Rated for continuous operation and is com-
pletely maintenance-free.
• Integrated overheating protection.
Accessories
Backdraft
Air ducts Grilles and hoods dampers Speed controllers Clamps
Model
40 VENTS 100 Flip ØD B L L1
30
25
20
15
10
0
0 10 20 30 40 50 60 70 80 90
Air flow [m3/h]
Technical data
Mounting example
Certificates
IP44 The fans meet the applicable safety and electromagnetic compatibility standards.
• Motor equipped with overheating protection. • Speed control is possible through a thyristor\
speed controller (see Electrical Accessories). Several
fans may connected to the same controller. Speed
Modifications and Options controllers can not be connected to the fans with T,
TH, TP, VT, VTH modification.
MF L – the motor is equipped with ball
bearings for long service life (appr. 40 Automatic:
thousand hours) and fan mounting at • By the electronic control unit BU-1-60. The
any angle. The bearings are maintenance-free and control unit is supplied separately.
contain enough grease for the entire operating
period.
• By the timer T (the built-in run-out timer enables
the fan operation within 2 to 30 minutes after the fan
MF T – off-delay timer modification switching off).
with operating time from 2 to 30 min.
• By the humidity sensor and timer TH (if the
humidity level in the room exceeds the sensor
Low-noise and energ saving threshold adjustable value within 60-90% the fan
MF T1 – modification with turn-on
axial fan for exhaust ventilation delay timer (adjustable from 0 to 2 switches automatically on and operates until the
with air capacity up to 255 m3/h humidity level drops to the standard level, after
minutes) and off-delay timer (adjustable
that the fan continues operating within the time
from 2 to 30 minutes).
period according to the timer setting, then shuts
Applications MF TH – off-delay timer down).
modification with the
• Continuous or periodic exhaust ventilation
operating time from 2 to 30
of bathroom, showers, kitchens and other utility Mounting features
spaces. min and humidity sensor with threshold from 60
to 90%. • The fan is mounted directly into the ventilation
• Ventilation of premises with high noise level
MF V – pull-cord switch modification.
shaft.
limitations. • Flexible duct application is recommended in
• Mounting into ventilation shafts or connection case of remote location of the ventilation shaft.
to Ø100, 125 and 150 mm air ducts. • The air duct is connected to the fan exhaust
MF VT – modification with flange through a clamp.
Design pull-cord switch and off-delay
timer with operating time
• Fixed to wall by self-tapping screws.
• The casing and the impeller are made of high- from 2 to 30 min. • Suitable for ceiling mounting.
quality durable ABS plastic, UV resistant.
MF VTH – modi-
• Specially designed impeller aerodynamic fication with pull-
profile provides high air capacity and low noise. cord switch, off-
• The fan is equipped with a back valve to delay timer with operating time from 2 to 30 min
prevent back flow and heat losses during the fan and humidity sensor with threshold from 60 to
standby. 90%.
• The fan exhaust spigot incorporates specially
designed air rectifiers to reduce air turbulence,
increase air pressure and lower noise level.
Accessories
Backdraft
Air ducts Grilles and hoods damper Speed controllers Clamps
Pressure ∆P [Pa]
Pressure ∆P [Pa]
40
VENTS 100 MF VENTS 125 MF VENTS 150 MF
VENTS 100 MF 12 60 60
35
50 50
30
25 40 40
20 30 30
15
20 20
10
10 10
5
0 0 0
0 10 20 30 40 50 60 70 80 90 100 0 20 40 60 80 100 120 140 160 180 0 40 80 120 160 200 240 280
Air capacity [m3/ h] Air capacity [m3/ h] Air capacity [m3/ h]
Technical data
Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]
VENTS 100 MF 50
VENTS 100 MF 220-240 8 0.05 2165 90 29 0.45
60
(220 V/60 Hz)
VENTS 100 MF 12 50 12 8 1.02 2075 85 28 0.45
VENTS 125 MF 50
VENTS 125 MF 220-240 18 0.11 2200 160 34 0.80
60
(220 V/60 Hz)
VENTS 150 MF 230 220-240 28 0.21 1545 255 35 0.97
Overall dimensions
Dimensions [mm]
Model
ØD B L L1
VENTS 100 MF 99 150 79 19
VENTS 125 MF 124 180 85 21
VENTS 150 MF 148 205 112 23
Mounting example
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.
Accessories
Backdraft
Air ducts Grilles and hoods damper Speed controllers Clamps
Pressure, ΔP [Pa]
Pressure, ΔP [Pa]
50 VENTS 100 MF Duo 40 VENTS 125 MF Duo 90 VENTS 150 MF Duo
45 80
35
40
70
30
35
60
30 25
max 50
25 max
20
max
min 40
20
15
30
15
min 10 min
20
10
5 10
5
0 0 0
0 10 20 30 40 50 60 70 80 90 0 25 50 75 100 125 150 175 0 50 100 150 200 250 300
Air flow [m3/ h] Air flow [m3/ h] Air flow [m3/ h]
Technical data
Frequency Voltage Power Current Maximum air Sound pressure level Weight
Model Speed RPM [min-1] IP Code
[Hz] [V] [W] [A] flow [m3/h] at 3 m distance [dBA] [kg]
Overall dimensions
Dimensions [mm]
Model
ØD B L L1
VENTS 100 MF Duo 99 150 79 19
VENTS 125 MF Duo 124 180 85 21
VENTS 150 MF Duo 148 205 112 23
Application example
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.
Accessories
Backdraft Speed
Air ducts Grilles and hoods damper controller Clamps
Pressure ∆P [Pa]
VENTS Casto 100 VENTS Casto 150
40
60 VENTS Casto 100-12 60 60 60
35
50 50 50 50
30
40
25 40 40 40
20
30 30 30 30
15
20 20 20 20
10
10 10 10 10
5
00 0 0 0
80 90 100 00 1020 20 4030 6040 80
50 60
100 70
120 8014090 160 100 180 0 0 20 40
40 60
80 80
120 100160120 200140 240 160 180
280 0 40 80 120 160 200 240 280
Air flow [m3/ h] Air flow [m3/ h]
Technical data
Overall dimensions
Dimensions [mm]
Model
ØD B L L1
VENTS Casto 100 99 150 79 23
VENTS Casto 150 148 206 112 23
Mounting example
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.
• Designed for continuous operation and requires • Flexible duct connection is recommended in
no maintenance. case of the remote ventilation shaft location. The
air duct is connected to the fan exhaust flange by
• Equipped with overheating protection. means of a clamp.
• Wall fixing with screws.
Modifications and options
• Suitable for ceiling mounting.
Casto L Duo – the motor is equipped
with ball bearings to increase the ser-
vice life (about 40000 of operating hours)
and a fan, mounting at any angle. The bearings are
maintenance-free and contain enough grease for
the entire operating period.
Casto T1 Duo – equipped with an adjust-
able high-speed turn-on delay timer (from
0 to 2 minutes) and an adjustable high-
speed turn-off delay timer (from 2 to 30 minutes).
Two-speed axial low-noise and low Casto TH Duo – equipped with
energy fans for exhaust ventilation an adjustable turn-off delay tim-
with air flow up to 300 m3/h er (from 2 to 30 minutes) and a
fixed turn-on delay timer (45 s) with a humidity sen-
sor adjustable from 60 % to 90 %.
Application
Control
• Continuous or periodic exhaust ventilation of Manual:
bathroom, showers, kitchens, and other residential
premises.
• The fan is operated via light switch (not included
in the delivery set).
• Ventilation of premises with high requirements
Automatic:
to noise level.
• Permanent low-speed operation mode ensures
• By the T1 timer. When the external switch is
turned on, the fan switches to a higher speed with
continuous air exchange in the room.
a delay of 0 to 2 minutes. When the external switch
• Ventilation shaft mounting or connection to is turned off, the fan will return to a low speed with a
Ø 100 and 150 mm air ducts. delay of 2 to 30 minutes.
• By a humidity sensor and the TH timer. If the
Design humidity level in the room exceeds the sensor
threshold (60-90 %), the fan will automatically switch
• The casing and the impeller are made of high- to a higher speed and will continue running until
quality durable plastic, UV resistant. humidity returns to normal levels. Then the fan runs
• The aerodynamic design of the impeller ensures for 5 minutes at a high speed and switches to a low
high air flow and low noise level. speed. The fan with the TH timer and a humidity
sensor can also be controlled in manual mode, for
• The fan is equipped with a specially designed
example, using the light switch. When the control
backdraft damper to prevent back flow and heat
voltage is applied, the turn-on delay timer is activa
losses during the fan standby.
ted for 45 seconds and the fan switches to the se
• The fan outlet spigot incorporates specially de- cond speed. After disconnecting the control voltage,
signed air rectifiers to reduce air turbulence, noise the fan runs for a time set by the turn-off delay timer
level and increase air pressure. (from 2 to 30 minutes), and switches to the first
speed.
Accessories
Backdraft
Air ducts Grilles and hoods dampers Clamps
Pressure, ΔP [Pa]
50
VENTS Casto 100-Duo VENTS Casto 150-Duo
90
45 80
40
70
35
60
30
50
25 max
max 40
20
30
15
min min
20
10
5 10
0 0
0 10 20 30 40 50 60 70 80 90 0 50 100 150 200 250 300
Air flow [m3/h] Air flow [m3/h]
Technical data
Overall dimensions
Dimensions [mm]
Model
ØD B L L1
VENTS Casto 100-Duo 99 150 79 23
VENTS Casto 150-Duo 148 206 112 23
Application example
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.
Axial inline fans, for exhaust or supply ventilation with the capacity up to 375 m3/h. Compatible
with Ø 100, 125 and 150 mm air ducts.
Axial inline fans, for exhaust or supply ventilation with the capacity up to 358 m3/h. Compatible
with Ø 100, 125 and 150 mm air ducts.
Axial inline fans, for exhaust or supply ventilation with the capacity up to 365 m3/h. Compatible
with Ø 100, 125 and 150 mm air ducts.
Accessories
Diffusers and air disk valves Air ducts Grilles and hoods Backdraft Speed controllers Control unit
damper
• The impeller design enhances fan efficiency and ensures low-noise operation of the fan.
• Ingress protection rating IPX4.
Model L ØD k
Aerodynamic characteristics
60 60 60
VENTS Quietline 100 VENTS Quietline 100 Duo VENTS Quietline 100 12
50 50 50
40 40 40
30 30 30
max
20 20 20
min
10 10 10
0 0 0
0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100
Air flow Air flow Air flow
80
80 8080 120 80
VENTS
VENTSQuietline
Quietline125
125 VENTS
VENTSQuietline125
Quietline125Duo
Duo VENTS Quietline 150
70
70 7070 70
100
60
60 6060 60
80
50
50 5050 50
40
40 4040 60 40
max
max
30
30 3030 30
min
min 40
20
20 2020 20
20
10
10 1010 10
00 00 0 0
00 50
50 100
100 150
150 200
200 00 5050 100
100 150
150 200
200 0 50 100 150 200 250 300 350 0 50
Air
Airflow
flow AirAir
flow
flow Air flow
8080 80 120
120
120 140
140
140
uietline
150150
tline150
ine VENTS
VENTS
VENTS Quietline
Quietline
Quietline 150QQ
150 VENTS Quietline
VENTSQuietline 150
Quietline150 Duo
150Duo
Duo VENTS Quietline
Quietline
VENTS 150
150
Quietline Extra
Extra
150 Extra
7070 70 120
120
120
100
100
100
6060 60
100
100
100
8080
80
5050 50
8080
80
4040 40 6060
60
max
max
max max
max
max
6060
60
3030 30
4040
40
4040
40
2020 20
min
min
2020
20 min
min
min
2020
20
1010 10
00 0 00 0 00 0
250300
300300350
350350 00 0 50 50 100
50 100100 150
150150 200
200200 250
250
250 300
300 350
350 00 0 50
50
50 100
100
100 150
150
150 200
200 250
250
250 300
300
300 350
350
350 00 0 5050 100 150150 200
100 200200 250
250250 300
300300 350
350350 400
400400
AirAir Air flow
flow
flow AirAir flow
flow Air
Air flow
Airflow
flow Air
Airflow
flow
Air flow
Mounting examples
Mounting examples
VKOk fan cottage
ventilation example
Accessories
Backdraft
Diffusers and air disk valves Air ducts Grilles and hoods damper Speed controllers Clamps
Technical data
Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consump- R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
tion [W]
Overall dimensions
Dimensions [mm]
Model
Ø D Ø D1 B B1 H L L1 L2 L3
VENTS 100 VKO 100 104 – – – 91 31 – –
VENTS 100 VKOk 100 104 160 144 114 91 31 45 29
VENTS 125 VKO 125 129 – – – 93 31 – –
VENTS 125 VKOk 125 129 185 169 139 93 31 45 29
VENTS 150 VKO 150 154 – – – 108 46 – –
VENTS 150 VKOk 150 154 200 184 163 108 46 45 29
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.
• Continuous or periodic exhaust ventilation • Two fans can be installed in series for higher
of bathroom, showers, kitchens and other utility performance.
VKO1 press – 5-blade low-noise
spaces.
impeller with improved aerodynamics • For 12 V low-voltage motor fan connection
• Exhaust or supply ventilation depending on for higher fan capacity.
to 220 V/50 Hz power mains use the step-down
the fan mounting type in the system. transformer TRF 220/12-25 that is available upon
VKO1 12 – modification with low- separate order.
• Designed for PVC ducting systems or flexible voltage motor. 12 V AC power supply.
ducts.
• Low to medium air flow motion for short VKO1 T – equipped with a regulated
distances at low air resistance.
timer with the operating time from
• Compatible with Ø 100, 125 and 150 mm air 2 to 30 minutes.
ducts.
Mounting examples
VKO1 fan flat
ventilation example
Accessories
Backdraft
Diffusers and air disk valves Air ducts Grilles and hoods damper Speed controllers Clamps
Technical data
Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]
Overall dimensions
Dimensions [mm]
Model
ØD Ød B B1 H L L1 L2 L3
VENTS 100 VKO1 100 59 – – – 85 28 – –
VENTS 100 VKO1k 100 59 160 144 110 85 28 45 29
VENTS 125 VKO1 125 59 – – – 90 28 – –
VENTS 125 VKO1k 125 59 185 169 125 90 28 45 29
VENTS 150 VKO1 150 59 – – – 100 28 – –
VENTS 150 VKO1k 150 59 200 184 162 100 28 45 29
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.
Axial fans for exhaust ventilation with the capacity up to 365 m3/h. Compatible with Ø 100, 125 or
150 mm air ducts. Some models are equipped with automatic or manual louver shutters. Wide range of
designs and options.
Axial fans
VENTS M Series page
Axial fans
VENTS M3 Series page
Axial fans
VENTS M1 Series page
Axial fans
VENTS X1 Series page
Axial fans
VENTS Simple Series page
Axial fans
VENTS F Series page
Axial fans
VENTS K Series page
Air flow up to 341 m /h3
104
Axial fans
VENTS K1 Series page
Air flow up to 226 m3/h 106
Axial fans
VENTS PF Series page
Air flow up to 342 m3/h 108
Axial fans
VENTS PF1 Series page
Air flow up to 349 m3/h 110
Axial fans
VENTS S Series page
Axial fans
VENTS D Series page
Axial fans
VENTS IFK Series page
Axial fans
VENTS IFT Series page
Air flow up to 78 m /h
3 117
Axial fans
VENTS IFP Series page
Air flow up to 80 m /h
3 118
Axial fans
damper for back flow preventing. • By the electronic control unit BU-1-60 (see
Electrical Accessories). The control unit is supplied
for exhaust ventilation separately.
M L – the motor is equipped with ball
with the capacity bearings for long service life (appr. 40 • By the timer T (the built-in turn-off delay timer
up to 345 m3/h thousand hours) and fan mounting at enables the fan operation within 2 to 30 minutes
any angle. The bearings are maintenance-free and after the fan switching off ).
Application
contain enough grease for the entire operating • By the humidity sensor and timer TH (if the
period. humidity level in the room exceeds the sensor
• Continuous or periodic exhaust ventilation M turbo – high-powered motor. threshold adjustable value within 60-90 % the fan
of bathroom, showers, kitchens and other utility switches automatically on and operates until the
spaces. humidity level drops to the standard level, after
that the fan continues operating within the time
• Ventilation shaft mounting or duct connec-
M press – 5-blade low-noise impeller period according to the timer setting, then shuts
tion.
with improved aerodynamics for higher down).
• Low to medium air flow motion for short dis- fan capacity. • By the motion sensor and the timer TP (in case
tances at low air resistance.
M 12 – modification with low-voltage of motion detection the fan switches automatically
• Compatible with Ø 100, 125 and 150 mm air motor. 12 V AC power supply. on and operates within the set time period from
ducts. 2 to 30 minutes. The motion sensitivity area is up
to 4 meters and the maximum detection angle is
MT – equipped with a regulated timer 100°).
with the operating time from 2 to 30
minutes.
Mounting features
MTH – equipped with a timer
with the operating time from 2 • The fan is mounted directly into the ventilation
to 30 minutes and a humidity shaft or used for ceiling mounting with the
sensor with the threshold value from 60 to 90 %. connection to the duct.
MV – equipped with a pull cord switch. • Flexible duct application is recommended in
case of remote location of the ventilation shaft.
The air duct is connected to the fan exhaust flange
through a clamp.
MVT – equipped with a pull
cord switch and a regulated • Fixed to wall by self-tapping screws.
timer with the operating time • For 12 V low-voltage motor fan connection
adjustable from 2 to 30 minutes. to 220 V/50 Hz power mains use the step-down
MVTH – equipped transformer TRF 220/12-25 that is available upon
with a pull cord separate order.
switch, regulated
timer with the operating time adjustable from
2 to 30 minutes and a humidity sensor with the
operating threshold range from 60 to 90 %.
Accessories
Backdraft
Air ducts Grilles and hoods damper Speed controllers Clamps
Pressure, ΔP (Pa)
Pressure, ΔP (Pa)
VENTS 100 M VENTS 125 M VENTS 150 M
VENTS 100 M turbo VENTS 125 M turbo VENTS 150 M turbo
VENTS 100 M press VENTS 125 M press VENTS 150 M press
VENTS 100 M VENTS 125 M VENTS 150 M
(127-220 V/60 Hz) (127-220 V/60 Hz) (127-220 V/60 Hz)
VENTS 100 M 12 VENTS 125 M 12 VENTS 150 M 12
Technical data
Frequency Power Current Maximum air Sound Pressure Weight
Model Voltage [V] R.p.m.
[Hz] Consumption [W] [A] flow [m3/h] Level at 3 m [dBA] [kg]
M fan kitchen
ventilation example
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.
Accessories
Backdraft
Air ducts Grilles and hoods damper Speed controllers Clamps
Technical data
Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]
VENTS 100 M3 50/60 220-240 14 0.085 2300 98 34 0.61
VENTS 100 M3 turbo 50/60 220-240 16 0.1 2300 128 37 0.69
VENTS 100 M3 press 50/60 220-240 16 0.1 2300 99 37 0.69
VENTS 100 M3 12 50/60 12 14 1.5 2200 86 33 0.60
VENTS 125 M3 50/60 220-240 16 0.1 2400 185 35 0.80
VENTS 125 M3 turbo 50/60 220-240 22 0.105 2400 232 40 0.86
VENTS 125 M3 press 50/60 220-240 22 0.105 2400 188 39 0.87
VENTS 125 M3 12 50/60 12 16 1.7 2300 165 34 0.78
VENTS 150 M3 50 220-240
VENTS 150 M3 24 0.13 2400 295 39 0.95
60 220
(220 V/60 Hz)
VENTS 150 M3 turbo 50 220-240
VENTS 150 M3 turbo 29 0.13 2400 345 43 1.01
60 220
(220 V/60 Hz)
VENTS 150 M3 press 50 220-240
VENTS 150 M3 press 29 0.13 2400 307 41 1.03
60 220
(220 V/60 Hz)
Dimensions [mm]
Model
ØD B B1 H H1 L L1
VENTS 100 M3 100 185 155 256 226 86 30
VENTS 125 M3 125 185 155 256 226 89 30
VENTS 150 M3 150 185 155 256 226 114 30
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.
Axial fans
M1 K – fan is equipped with a backdraft • By the electronic control unit BU-1-60 (see
damper for back flow preventing. Electrical Accessories). The control unit is supplied
for exhaust ventilation separately.
with the capacity
M1 L – The motor is equipped with ball • By the timer T (the built-in turn-off delay timer
up to 345 m3/h enables the fan operation within 2 to 30 minutes
bearings for long service life (appr. 40
after the fan switching off ).
thousand hours) and fan mounting at
Application
any angle. The bearings are maintenance-free and • By the humidity sensor and timer TH (if the
contain enough grease for the entire operating humidity level in the room exceeds the sensor
• Continuous or periodic exhaust ventilation period. threshold adjustable value within 60-90 % the fan
of bathroom, showers, kitchens and other utility switches automatically on and operates until the
M1 turbo – high-powered motor.
spaces. humidity level drops to the standard level, after
that the fan continues operating within the time
• Ventilation shaft mounting or duct connec-
period according to the timer setting, then shuts
tion.
M1 press – 5-blade low-noise impeller down).
• Low to medium air flow motion for short dis-
with improved aerodynamics for higher • By the motion sensor and the timer TP (in case
tances at low air resistance.
fan capacity. of motion detection the fan switches automatically
• Compatible with Ø 100, 125 and 150 mm air M1 12 – modification with low-voltage on and operates within the set time period from
ducts. 2 to 30 minutes. The motion sensitivity area is up
motor. 12 V AC power supply.
to 4 meters and the maximum detection angle is
100°).
M1T – equipped with a regulated timer
with the operating time from 2 to 30 Mounting features
minutes.
M1TH – equipped with a • The fan is mounted directly into the ventilation
timer with the operating time shaft.
from 2 to 30 minutes and a • Flexible duct application is recommended in
humidity sensor with the threshold value from 60 case of remote location of the ventilation shaft.
to 90 %. The air duct is connected to the fan exhaust flange
M1V – equipped with a pull cord through a clamp.
switch. • Fixed to wall by self-tapping screws.
• For 12 V low-voltage motor fan connection
M1VT – equipped with a pull to 220 V/50 Hz power mains use the step-down
cord switch and a regulated transformer TRF 220/12-25 that is available upon
timer with the operating time separate order.
adjustable from 2 to 30 minutes.
M1VTH – equipped
with a pull cord
switch, regulated
timer with the operating time adjustable from
2 to 30 minutes and a humidity sensor with the
operating threshold range from 60 to 90 %.
Accessories
Backdraft
Air ducts Grilles and hoods damper Speed controllers Clamps
Technical data
Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]
VENTS 100 M1 50/60 220-240 14 0.085 2300 98 34 0.51
VENTS 100 M1 turbo 50/60 220-240 16 0.1 2300 128 37 0.65
VENTS 100 M1 press 50/60 220-240 16 0.1 2300 99 37 0.65
VENTS 100 M1 12 50/60 12 14 1.5 2200 86 33 0.51
VENTS 125 M1 50/60 220-240 16 0.1 2400 185 35 0.68
VENTS 125 M1 turbo 50/60 220-240 22 0.105 2400 232 40 0.81
VENTS 125 M1 press 50/60 220-240 22 0.105 2400 188 39 0.81
VENTS 125 M1 12 50/60 12 16 1.7 2300 165 34 0.68
VENTS 150 M1 50 220-240
VENTS 150 M1 24 0.13 2400 295 39 0.80
60 220
(220 V/60 Hz)
VENTS 150 M1 turbo 50 220-240
VENTS 150 M1 turbo 29 0.13 2400 345 43 0.99
60 220
(220 V/60 Hz)
VENTS 150 M1 press 50 220-240
VENTS 150 M1 press 29 0.13 2400 307 41 0.99
60 220
(220 V/60 Hz)
Dimensions [mm]
Model
ØD B B1 B2 H L L1
VENTS 100 M1 100 165 150 150 150 92 32
VENTS 125 M1 125 190 174 128 173 98 33
VENTS 150 M1 150 212 196 150 195 114 33
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.
• Reliable and low-watt electric motor. • By the humidity sensor and timer TH (if the
humidity level in the room exceeds the sensor
• Designed for continuous operation and threshold adjustable value within 60-90 % the fan
requires no maintenance. switches automatically on and operates until the
• Equipped with overheating protection. humidity level drops to the standard level, after
that the fan continues operating within the time
Modifications and Options period according to the timer setting, then shuts
Axial fans with automatic louver down).
shutters for exhaust ventilation MA L – the motor is equipped with ball
with the capacity up to 345 m3/h bearings for long service life (appr. 40
• By the motion sensor and the timer TP (in case
of motion detection the fan switches automatically
thousand hours) and fan mounting at on and operates within the set time period from
any angle. The bearings are maintenance-free and 2 to 30 minutes. The motion sensitivity area is up
Application contain enough grease for the entire operating to 4 meters and the maximum detection angle is
period. 100°).
• Continuous or periodic exhaust ventilation MA turbo – high-powered motor.
of bathroom, showers, kitchens and other utility
spaces. Mounting features
• Ventilation shaft mounting or duct connection.
MA press – 5-blade low-noise • The fan is mounted directly into the ventilation
• Low to medium air flow motion for short impeller with improved aerodynamics shaft.
distances at low air resistance. for higher fan capacity. • Flexible duct application is recommended in
• Compatible with Ø 100, 125 and 150 mm air MA 12 – modification with low-voltage case of remote location of the ventilation shaft.
ducts. motor. 12 V AC power supply. The air duct is connected to the fan exhaust flange
through a clamp.
Accessories
Air ducts Grilles and hoods Speed controllers Clamps
Technical data
Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]
VENTS 100 MA 50/60 220-240 18 0.085 2300 98 34 0.65
VENTS 100 MA turbo 50/60 220-240 20 0.1 2300 128 37 0.65
VENTS 100 MA press 50/60 220-240 20 0.1 2300 99 37 0.65
VENTS 100 MA 12 50/60 12 18 1.5 2200 86 33 0.65
VENTS 125 MA 50/60 220-240 22 0.1 2400 185 35 0.75
VENTS 125 MA turbo 50/60 220-240 29 0.13 2400 232 37 0.81
VENTS 125 MA press 50/60 220-240 29 0.13 2400 188 39 0.81
VENTS 125 MA 12 50/60 12 22 1.7 2300 165 34 0.75
VENTS 150 MA 50 220-240
VENTS 150 MA 26 0.13 2400 295 39 1.02
60 220
(220 V/60 Hz)
VENTS 150 MA turbo 50 220-240
VENTS 150 MA turbo 32 0.13 2400 345 41 0.99
60 220
(220 V/60 Hz)
VENTS 150 MA press 50 220-240
VENTS 150 MA press 32 0.14 2400 307 41 0.99
60 220
(220 V/60 Hz)
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.
Design
Control
• Modern design and aesthetic look.
Manual:
• The casing and the impeller are made of high-
• Three bottom control unit (included into
quality durable ABS plastic, UV resistant.
delivery set) with integrated circuit board is used
• The intellectual impeller design makes the fan for:
efficiency high and the service life long.
1. On/off switching;
• Fan is equipped with a thermal actuator
2. Fan speed switching (min – max);
that provides smooth opening and shutting
of automatic louver shutters for air back flow 3. Fan operation mode switching (exhaust –
Axial reverse fans for exhaust and preventing. supply mode).
supply ventilation with the capacity • Supplied with a three bottom control unit and
up to 202 m3/h 220 V – 12 V transformer. Mounting features
• Transformer provides reliable fan operation
• Fan is designed for indoor mounting on the
with safe power supply 12 V. external wall and is connected to the air duct.
• Protection rating IP24.
• Fastening with screws. Flexible air duct is
connected to exhaust flange with a clamp.
Fan off – louver shutters CLOSED Control unit Supply mode 1 speed Off
Fan on – louver shutters OPEN Fan operation in EXHAUST mode Fan operation in SUPPLY mode
Accessories
Air ducts Grilles and hoods Clamps
Technical data
Mounting set
Dimensions [mm]
Model
ØD B B1 B2 H L L1
VENTS 150 MA reverse 150 212 196 150 195 114 33
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.
Accessories
Backdraft
Air ducts Grilles and hoods damper Speed controllers Clamps
Pressure, ΔР [Pa]
Pressure, ΔР [Pa]
Pressure, ΔР [Pa]
VENTS 100 Х1 VENTS 120 Х1 VENTS 125 Х1 VENTS 150 Х1
VENTS 100 Х1 turbo VENTS 120 Х1 turbo VENTS 125 Х1 turbo VENTS 150 Х1 turbo
VENTS 100 Х1 12 VENTS 120 Х1 12 VENTS 125 Х1 12 VENTS 150 Х1 12
Air flow [m3/h] Air flow [m3/h] Air flow [m3/h] Air flow [m3/h]
Technical data
Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]
VENTS 100 X1 50 220-240
14 0.085 2300 99 33 0.60
VENTS 100 X1 (220 V/60 Hz) 60 220
VENTS 100 X1 turbo 50 220-240
16 0.1 2300 129 37 0.68
VENTS 100 X1 turbo (220 V/60 Hz) 60 220
VENTS 100 X1 12 50 12 14 1.5 2200 86 33 0.59
VENTS 120 X1 50 220-240
17 0.1 2400 179 35 0.73
VENTS 120 X1 (220 V/60 Hz) 60 220
VENTS 120 X1 turbo 50 220-240
24 0.105 2400 225 37 0.80
VENTS 120 X1 turbo (220 V/60 Hz) 60 220
VENTS 120 X1 12 50 12 16 1.7 2300 160 34 0.71
VENTS 125 X1 50 220-240
16 0.1 2400 185 34 0.73
VENTS 125 X1 (220 V/60 Hz) 60 220
VENTS 125 X1 turbo 50 220-240
24 0.105 2400 232 37 0.80
VENTS 125 X1 turbo (220 V/60 Hz) 60 220
VENTS 125 X1 12 50 12 16 1.7 2300 160 34 0.71
VENTS 150 X1 50 220-240
24 0.13 2400 295 37 0.92
VENTS 150 X1 (220 V/60 Hz) 60 220
VENTS 150 X1 turbo 50 220-240
29 0.13 2400 345 41 1.06
VENTS 150 X1 turbo (220 V/60 Hz) 60 220
VENTS 150 X1 12 50 12 29 2 2300 263 36 0.88
Dimensions [mm]
Model
ØD B H L L1
VENTS 100 X1 100 152 120 108 12
VENTS 120 X1 120 177 140 95 13
VENTS 125 X1 125 177 140 114 13
VENTS 150 X1 150 205 165 132 13
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.
• Equipped with overheating protection. • The fan is controlled by the built-in V pull cord
switch. Not applied in case of ceiling mounting.
Modifications and Options • Speed control is possible through a thyristor
speed controller (see Electrical Accessories). Several
Simple K – fan is equipped with a backdraft fans may be connected to the same controller. Speed
damper for back flow preventing. controllers can not be connected to the fans with the
T, TH, TP, VT, VTH modifications.
Simple L – the motor is equipped with Automatic:
ball bearings for long service life (appr. • By the BU-1-60 electronic control unit (see
40 thousand hours) and fan mounting at Electrical Accessories). The control unit is supplied
any angle. The bearings are maintenance-free and separately.
contain enough grease for the entire operating
period.
• By the T timer (the built-in turn-off delay timer
enables the fan operation within 2 to 30 minutes
Simple turbo – high-powered motor. after the fan switching off).
Accessories
Backdraft
Air ducts Grilles and hoods damper Speed controllers Clamps
Pressure ∆P [Pa]
Pressure ∆P [Pa]
Pressure ∆P [Pa]
100 Simple turbo 120 Simple turbo 125 Simple turbo 150 Simple
40 80
100 Simple 60 120 Simple 60 125 Simple
35 70
50 50
30 60
25 40 40 50
20 30 30 40
15 30
20 20
10 20
10 10
5 10
0 0 0 0
0 20 40 60 80 100 120 140 0 40 80 120 160 200 240 0 40 80 120 160 200 240 0 50 100 150 200 250 300
Air flow [m3/h] Air flow [m3/h] Air flow [m3/h] Air flow [m3/h]
Technical data
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.
• The casing and the impeller are made of high- • The fan is controlled by a room light switch. It
quality durable ABS plastic, UV resistant. is not included in the delivery package.
• The intellectual impeller design makes the fan • Speed control is possible through a thyristor
efficiency high and the service life long. speed controller (see Electrical Accessories).
Several fans may connected to the same controller.
• The special front grille design enables natural Speed controllers can not be connected to the
ventilation of the premises without powering up fans with T, TH, TP, VT, VTH modification.
the fan if required.
Automatic:
• Insect screen.
• Protection rating IP34.
• By the electronic control unit BU-1-60 (see
Electrical Accessories). The control unit is supplied
• Ventilation grille for natural air exhaust for separately.
application in premises with gas stoves.
Mounting features
Motor • The fan is mounted directly into the ventilation
shaft.
• Reliable and low-watt electric motor.
• Designed for continuous operation and • Flexible duct application is recommended in
case of remote location of the ventilation shaft.
requires no maintenance.
The air duct is connected to the fan exhaust flange
• Equipped with overheating protection. through a clamp.
• Fixed to wall by self-tapping screws.
Modifications and Options
• For 12 V low-voltage motor fan connection
F L – the motor is equipped with ball to 220 V/50 Hz power mains use the step-down
Axial fans bearings for long service life (appr. 40 transformer TRF 220/12-25 that is available upon
for exhaust ventilation thousand hours) and fan mounting at separate order.
with the capacity up to 232 m3/h any angle. The bearings are maintenance-free and
contain enough grease for the entire operating
period.
Application F turbo – high-powered motor.
• Continuous or periodic exhaust ventilation
of bathroom, showers, kitchens and other utility
spaces. F 12 – modification with low-voltage
• Ventilation shaft mounting or duct connec- motor. 12 V AC power supply.
tion.
• For rectangular ventilation shafts.
• Low to medium air flow motion for short dis-
tances at low air resistance.
• Compatible with Ø 100 and 125 mm air ducts.
Accessories
Backdraft
Air ducts Grilles and hoods damper Speed controllers Clamps
Technical data
Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]
Dimensions [mm]
Model
ØD B B1 B2 H H1 L L1
VENTS 100 F 100 182 152 160 252 226 104 13
VENTS 125 F 125 182 152 160 252 226 110 15
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.
• The casing and the impeller are made of high- • The fan is controlled by a room light switch. It
quality durable ABS plastic, UV resistant. is not included in the delivery package.
• The intellectual impeller design makes the fan • Speed control is possible through a thyristor
efficiency high and the service life long. speed controller (see Electrical Accessories).
Several fans may connected to the same controller.
• The special front grille design enables natural Speed controllers can not be connected to the
ventilation of the premises without powering up fans with T, TH, TP, VT, VTH modification.
the fan if required.
Automatic:
• The enlarged front grille is specifically
designed to fit non-standard ventilation shafts. • By the electronic control unit BU-1-60 (see
Electrical Accessories). The control unit is supplied
• Insect screen. separately.
• Protection rating IP34.
• By the timer T (the built-in turn-off delay timer
• Ventilation grille for natural air exhaust for enables the fan operation within 2 to 30 minutes
application in premises with gas stoves. after the fan switching off ).
• Reliable and low-watt electric motor. • The fan is mounted directly into the ventilation
shaft.
• Designed for continuous operation and
• Flexible duct application is recommended in
requires no maintenance.
case of remote location of the ventilation shaft.
• Equipped with overheating protection. The air duct is connected to the fan exhaust flange
Axial fans through a clamp.
for exhaust ventilation Modifications and Options • Fixed to wall by self-tapping screws.
with the capacity up to 232 m3/h F1 L – the motor is equipped with ball • For 12 V low-voltage motor fan connection
bearings for long service life (appr. 40 to 220 V/50 Hz power mains use the step-down
thousand hours) and fan mounting at transformer TRF 220/12-25 that is available upon
Application any angle. The bearings are maintenance-free and separate order.
contain enough grease for the entire operating
• Continuous or periodic exhaust ventilation period.
of bathroom, showers, kitchens and other utility
spaces. F1 turbo – high-powered motor.
• Ventilation shaft mounting or duct connec-
tion.
• Designed for non-standard ventilation shafts F1 12 – modification with low-voltage
with a large cross section. motor. 12 V AC power supply.
• Low to medium air flow motion for short dis-
tances at low air resistance. F1T – equipped with a regulated timer
• Compatible with Ø 100 and 125 mm air ducts. with the operating time from 2 to 30
minutes.
Accessories
Backdraft
Air ducts Grilles and hoods damper Speed controllers Clamps
Technical data
Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]
Dimensions [mm]
Model
ØD B B1 B2 H H1 L L1
VENTS 100 F1 100 182 152 160 252 226 128 13
VENTS 125 F1 125 182 152 160 252 226 134 15
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.
• The casing and the impeller are made of high- • The fan is controlled by a room light switch. It
quality durable ABS plastic, UV resistant. is not included in the delivery package.
• The intellectual impeller design makes the fan • Speed control is possible through a thyristor
efficiency high and the service life long. speed controller (see Electrical Accessories).
Several fans may connected to the same controller.
• Insect screen. Speed controllers can not be connected to the
• Protection rating IP34. fans with T, TH, TP, VT, VTH modification.
Automatic:
Motor
• By the electronic control unit BU-1-60 (see
• Reliable and low-watt electric motor. Electrical Accessories). The control unit is supplied
separately.
• Designed for continuous operation and
requires no maintenance.
Mounting features
• Equipped with overheating protection.
• The fan is mounted directly into the ventilation
shaft.
Modifications and Options
• Flexible duct application is recommended in
K L – the motor is equipped with ball case of remote location of the ventilation shaft.
bearings for long service life (appr. 40 The air duct is connected to the fan exhaust flange
Axial fans thousand hours) and fan mounting at through a clamp.
for exhaust ventilation any angle. The bearings are maintenance-free and • Fixed to wall by self-tapping screws.
with the capacity up to 341 m3/h contain enough grease for the entire operating
period. • Suitable for ceiling mounting.
Accessories
Backdraft
Air ducts Grilles and hoods damper Speed controllers Clamps
Technical data
Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]
Dimensions [mm]
Model
ØD B H L L1
VENTS 100 K 100 154 110 105 15
VENTS 125 K 125 187 142 112 15
VENTS 150 K 150 250 214 127 15
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.
• The casing and the impeller are made of high- • The fan is controlled by a room light switch. It
quality durable ABS plastic, UV resistant. is not included in the delivery package.
• The intellectual impeller design makes the fan • Speed control is possible through a thyristor
efficiency high and the service life long. speed controller (see Electrical Accessories).
Several fans may connected to the same controller.
• Insect screen. Speed controllers can not be connected to the
• Protection rating IP34. fans with T, TH, TP, VT, VTH modification.
Automatic:
Motor
• By the electronic control unit BU-1-60 (see
Electrical Accessories). The control unit is supplied
• Reliable and low-watt electric motor.
separately.
• Designed for continuous operation and
requires no maintenance.
Mounting features
• Equipped with overheating protection.
• The fan is mounted directly into the ventilation
shaft.
Modifications and Options
• Flexible duct application is recommended in
K1 L – The motor is equipped with ball case of remote location of the ventilation shaft.
bearings for long service life (appr. 40 The air duct is connected to the fan exhaust flange
Axial fans thousand hours) and fan mounting at through a clamp.
for exhaust ventilation any angle. The bearings are maintenance-free and • Fixed to wall by self-tapping screws.
with the capacity up to 226 m3/h contain enough grease for the entire operating
period. • Suitable for ceiling mounting.
Accessories
Backdraft
Air ducts Grilles and hoods damper Speed controllers Clamps
Technical data
Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]
Dimensions [mm]
Model
ØD B H L L1
VENTS 100 K1 100 154 110 108.5 18.5
VENTS 125 K1 125 187 142 116 19
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.
• The casing and the impeller are made of high- • The fan is controlled by a room light switch. It
quality durable ABS plastic, UV resistant. is not included in the delivery set.
• The intellectual impeller design makes the fan • Speed control is possible through a thyristor
efficiency high and the service life long. speed controller (see Electrical Accessories).
Several fans may be connected to the same
• Insect screen. controller. Speed controllers can not be
• Protection rating IP34. connected to the fans with the T, TH, TP, VT, VTH
modifications.
Motor Automatic:
• Reliable and low-watt electric motor. • By the BU-1-60 electronic control unit (see
Electrical Accessories). The control unit is supplied
• Designed for continuous operation and
separately.
requires no maintenance.
• Equipped with overheating protection. Mounting features
• The fan is mounted directly into the ventilation
Modifications and Options shaft.
PF L – the motor is equipped with ball • In case of remote location of the ventilation
bearings for long service life (appr. 40 shaft flexible air ducts may be used. The air duct
Axial fans for exhaust thousand hours) and fan mounting at is connected to the fan exhaust flange through a
ventilation with air capacity any angle. The bearings are maintenance-free and clamp.
up to 342 m3/h contain enough grease for the entire operating • Fixed to wall by self-tapping screws.
period.
• Suitable for ceiling mounting.
PF turbo – high-powered motor.
Application • To connect a fan with a 12 V low voltage motor
to 220 V/50 Hz power mains, it is necessary to
• Continuous or periodic exhaust ventilation purchase a step-down transformer (e.g. the TRF
of bathroom, showers, kitchens and other utility PF press – 5-blade low-noise impeller 220/12-25 transformer).
spaces. with improved aerodynamics for higher
• Ventilation shaft mounting or duct connec- fan capacity.
tion. PF 12 – modification with low-voltage
• Low to medium air flow motion for short dis- motor. 12 V AC power supply.
tances at low air resistance.
• Compatible with Ø 100, 125 and 150 mm air
ducts.
Accessories
Backdraft
Air ducts Grilles and hoods damper Speed controllers Clamps
Pressure, ΔP [Pa]
Pressure, ΔP [Pa]
VENTS 100 PF VENTS 125 PF VENTS 150 PF
VENTS 100 PF turbo VENTS 125 PF turbo VENTS 150 PF turbo
VENTS 100 PF press VENTS 125 PF press VENTS 150 PF press
VENTS 100 PF VENTS 125 PF VENTS 150 PF
(127-220 V/60 Hz) (127-220 V/60 Hz) (127-220 V/60 Hz)
VENTS 100 PF 12 VENTS 125 PF 12 VENTS 150 PF 12
Technical data
Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]
VENTS 100 PF 50/60 220-240 14 0.085 2300 98 34 0.47
VENTS 100 PF turbo 50/60 220-240 16 0.1 2300 120 40 0.52
VENTS 100 PF press 50/60 220-240 16 0.1 2300 99 38 0.47
VENTS 100 PF 127 10 0.115
(127-220 V/60 Hz) 60 2500 92 34 0.47
220 9 0.054
VENTS 100 PF 12 50/60 12 14 1.5 2200 86 33 0.46
VENTS 125 PF 50/60 220-240 16 0.1 2400 185 35 0.58
VENTS 125 PF turbo 50/60 220-240 24 0.1 2400 230 42 0.60
VENTS 125 PF press 50/60 220-240 24 0.105 2400 188 39 0.58
VENTS 125 PF 127 16 0.119
(127-220 V/60 Hz) 60 2400 190 36 0.58
220 15 0.102
VENTS 125 PF 12 50/60 12 16 1.7 2300 165 34 0.56
VENTS 150 PF 50 220-240
VENTS 150 PF 24 0.13 2400 292 38 0.90
60 220
(220 V/60 Hz)
VENTS 150 PF turbo 50 220-240
VENTS 150 PF turbo 29 0.13 2400 342 42 1.02
60 220
(220 V/60 Hz)
VENTS 150 PF press 50 220-240
VENTS 150 PF press 29 0.13 2400 304 40 0.90
60 220
(220 V/60 Hz)
VENTS 150 PF 127 25 0.175
(127-220 V/60 Hz) 60 2350 267 38 0.90
220 25 0.388
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.
• The intellectual impeller design makes the fan • Speed control is possible through a thyristor
efficiency high and the service life long. speed controller (see Electrical Accessories).
Several fans may connected to the same controller.
• Insect screen. Speed controllers can not be connected to the
• Protection rating IP34. fans with T, TH, TP, VT, VTH modification.
Automatic:
Motor
• By the electronic control unit BU-1-60 (see
Electrical Accessories). The control unit is supplied
• Reliable and low-watt electric motor.
separately.
• Designed for continuous operation and
requires no maintenance. • By the timer T (the built-in turn-off delay timer
enables the fan operation within 2 to 30 minutes
• Equipped with overheating protection.
after the fan switching off ).
Axial fans
PF1 L – The motor is equipped with ball • The fan is mounted directly into the ventilation
bearings for long service life (appr. 40 shaft.
for exhaust ventilation
with the capacity
thousand hours) and fan mounting at • Flexible duct application is recommended in
any angle. The bearings are maintenance-free and case of remote location of the ventilation shaft.
up to 349 m3/h contain enough grease for the entire operating The air duct is connected to the fan exhaust flange
period. through a clamp.
Application
PF1 turbo – high-powered motor. • Fixed to wall by self-tapping screws.
• Suitable for ceiling mounting.
• Continuous or periodic exhaust ventilation
• For 12 V low-voltage motor fan connection
of bathroom, showers, kitchens and other utility PF1 press – 5-blade low-noise impeller to 220 V/50 Hz power mains use the step-down
spaces. with improved aerodynamics for higher transformer TRF 220/12-25 that is available upon
• Ventilation shaft mounting or duct connec- fan capacity. separate order.
tion. PF1 12 – modification with low-voltage
• Low to medium air flow motion for short dis- motor. 12 V AC power supply.
tances at low air resistance.
• Compatible with Ø 100, 125 and 150 mm air PF1T – equipped with a regulated timer
ducts. with the operating time from 2 to 30
minutes.
Accessories
Backdraft
Air ducts Grilles and hoods damper Speed controllers Clamps
Technical data
Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]
VENTS 100 PF1 50/60 220-240 14 0.085 2300 100 33 0.47
VENTS 100 PF1 turbo 50/60 220-240 16 0.1 2300 122 39 0.58
VENTS 100 PF1 press 50/60 220-240 16 0.1 2300 101 38 0.47
VENTS 100 PF1 12 50/60 12 14 1.5 2300 88 32 0.47
VENTS 125 PF1 50/60 220-240 16 0.1 2400 190 35 0.70
VENTS 125 PF1 turbo 50/60 220-240 24 0.105 2400 232 42 0.75
VENTS 125 PF1 press 50/60 220-240 24 0.105 2400 190 39 0.70
VENTS 125 PF1 12 50/60 12 16 1.7 2400 169 34 0.70
VENTS 150 PF1 50 220-240
VENTS 150 PF1 24 0.13 2400 299 38 0.84
60 220
(220 V/60 Hz)
VENTS 150 PF1 turbo 50 220-240
VENTS 150 PF1 turbo 29 0.13 2400 349 40 0.98
60 220
(220 V/60 Hz)
VENTS 150 PF1 press 50 220-240
VENTS 150 PF1 press 29 0.13 2400 309 38 0.84
60 220
(220 V/60 Hz)
Dimensions [mm]
Model
ØD Ø D1 L L1
VENTS 100 PF1 100 141 128 13
VENTS 125 PF1 125 166 134 15
VENTS 150 PF1 150 188 146 15
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.
8 mm
Accessories
Backdraft
Air ducts Grilles and hoods damper Speed controllers Clamps
Pressure, ΔP [Pa]
Pressure, ΔP [Pa]
VENTS100 S VENTS125 S VENTS150 S
VENTS100 S turbo VENTS125 S turbo VENTS150 S turbo
VENTS100 S VENTS125 S VENTS150 S
(127-220 V/60 Hz) (127-220 V/60 Hz) (127-220 V/60 Hz)
VENTS100 S 12 VENTS125 S 12 VENTS150 S 12
Technical data
Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]
VENTS 100 S 50/60 220-240 14 0.085 2300 95 34 0.58
VENTS 100 S turbo 50/60 220-240 16 0.1 2300 124 37 0.66
VENTS 100 S 127 10 0.115
(127-220 V/60 Hz) 60 2500 90 34 0.59
220 9 0.054
VENTS 100 S 12 50/60 12 14 1.5 2200 86 33 0.60
VENTS 125 S 50/60 220-240 16 0.1 2400 180 35 0.75
VENTS 125 S turbo 50/60 220-240 24 0.105 2400 226 37 0.78
VENTS 125 S 127 16 0.119
(127-220 V/60 Hz) 60 2400 185 36 0.76
220 15 0.102
VENTS 125 S 12 50/60 12 16 1.7 2300 165 34 0.78
VENTS 150 S 50 220-240
VENTS 150 S 24 0.13 2400 292 38 1.13
60 220
(220 V/60 Hz)
VENTS 150 S turbo 50 220-240
VENTS 150 S turbo 29 0.13 2400 341 40 1.13
60 220
(220 V/60 Hz)
VENTS 150 S 127 25 0.175
(127-220 V/60 Hz) 60 2350 267 38 1.13
220 25 0.388
VENTS 150 S 12 50 12 24 2 2300 260 37 1.13
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.
6.5 mm
Accessories
Backdraft
Air ducts Grilles and hoods damper Speed controllers Clamps
Pressure, ΔP (Pa)
Pressure, ΔP (Pa)
VENTS 100 D VENTS 125 D VENTS 150 D
VENTS 100 D turbo VENTS 125 D turbo VENTS 150 D turbo
VENTS 100 D VENTS 125 D VENTS 150 D
(127-220 V/60 Hz) (127-220 V/60 Hz) (127-220 V/60 Hz)
VENTS 100 D 12 VENTS 125 D 12 VENTS 150 D 12
Technical data
Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]
VENTS 100 D 50/60 220-240 14 0.085 2300 95 34 0.58
VENTS 100 D turbo 50/60 220-240 16 0.1 2300 124 37 0.66
VENTS 100 D 127 10 0.115
(127-220 V/60 Hz) 60 2500 90 34 0.59
220 9 0.054
VENTS 100 D 12 50/60 12 14 1.5 2200 86 33 0.60
VENTS 125 D 50/60 220-240 16 0.1 2400 180 35 0.74
VENTS 125 D turbo 50/60 220-240 24 0.105 2400 226 37 0.81
VENTS 125 D 127 16 0.119
(127-220 V/60 Hz) 60 2400 185 36 0.75
220 15 0.102
VENTS 125 D 12 50/60 12 16 1.7 2300 165 34 0.69
VENTS 150 D 50 220-240
VENTS 150 D 24 0.13 2400 292 38 0.92
60 220
(220 V/60 Hz)
VENTS 150 D turbo 50 220-240
VENTS 150 D turbo 29 0.13 2400 341 40 1.06
60 220
(220 V/60 Hz)
VENTS 150 D 127 25 0.175
(127-220 V/60 Hz) 60 2350 267 38 0.93
220 25 0.388
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.
• Reliable motor on ball bearings with minimum • The air duct is connected to the fan exhaust
energy demand up to 5 W. flange through a clamp.
40
VENTS 125 IFK
35
30
25
20
Dimensions [mm]
15
Model
Ø D Ø D1 L L1
10 VENTS 125 IFK 125 166 55 13.5
5
0
0 10 20 30 40 50 60 70 80 90 100
Air flow [m3/h]
Technical data
Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m. IP
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]
Accessories
Air ducts Grilles and hoods Back valves Speed controllers Clamps
• Reliable motor on ball bearings with • The air duct is connected to the fan exhaust
minimum energy demand up to 5 W. flange through a clamp.
35
VENTS 125 IFT
30
25
20
Dimensions [mm]
15 Model
ØD B H L L1
10
VENTS 125 IFT 125 193 188 67 18
5
0
0 10 20 30 40 50 60 70 80 90 100
Air flow [m3/h]
Technical data
Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m. IP
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]
Accessories
Air ducts Grilles and hoods Back valves Speed controllers Clamps
• Reliable motor on ball bearings with minimum • The air duct is connected to the fan exhaust
energy demand up to 5 W. flange through a clamp.
up to 80 m3/h Motor
• Reliable motor with low energy demand.
• Designed for continuous operation and re-
quires no maintenance.
• The motor is equipped with overheating pro-
tection for 72 hours.
35
VENTS 125 IFP
30
25
20
Dimensions [mm]
15 Model
ØD B L L1
10
VENTS 125 IFP 125 186 59 15
5
0
0 10 20 30 40 50 60 70 80 90 100
Air flow [m3/h]
Technical data
Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m. IP
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]
Accessories
Air ducts Grilles and hoods Back valves Speed controllers Clamps
LD alumat
Accessories
Backdraft
Air ducts Grilles and hoods damper Speed controllers Clamps
Pressure, ΔP [Pa]
Pressure, ΔP [Pa]
VENTS100 LD VENTS125 LD VENTS150 LD
VENTS100 LD turbo VENTS125 LD turbo VENTS150 LD turbo
VENTS100 LD VENTS125 LD VENTS150 LD
(127-220 V/60 Hz) (127-220 V/60 Hz) (127-220 V/60 Hz)
VENTS100 LD 12 VENTS125 LD 12 VENTS150 LD 12
Technical data
Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]
VENTS 100 LD 50/60 220-240 14 0.085 2300 88 33 0.60
VENTS 100 LD turbo 50/60 220-240 16 0.1 2300 115 36 0.68
VENTS 100 LD 127 10 0.115
(127-220 V/60 Hz) 60 2500 82 33 0.60
220 9 0.054
VENTS 100 LD 12 50/60 12 14 1.5 2200 77 32 0.59
VENTS 125 LD 50/60 220-240 16 0.1 2400 167 34 0.74
VENTS 125 LD turbo 50/60 220-240 24 0.105 2400 209 36 0.84
VENTS 125 LD 127 16 0.119
(127-220 V/60 Hz) 60 2400 172 35 0.74
220 15 0.102
VENTS 125 LD 12 50/60 12 16 1.7 2300 149 33 0.72
VENTS 150 LD 50 220-240
VENTS 150 LD 24 0.13 2400 265 37 0.96
60 220
(220 V/60 Hz)
VENTS 150 LD turbo 50 220-240
VENTS 150 LD turbo 29 0.13 2400 310 39 1.10
60 220
(220 V/60 Hz)
VENTS 150 LD 127 25 0.175
(127-220 V/60 Hz) 60 2350 240 37 0.96
220 25 0.388
Dimensions [mm]
Model
ØD B H L L1
VENTS 100 LD 100 152 120 126 30
VENTS 100 LD1 100 152 120 111 30
VENTS 125 LD 125 177 140 135 34
VENTS 125 LD1 125 177 140 116 34
VENTS 150 LD 150 206 165 154 36
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.
Accessories
Air ducts Grilles and hoods Back valves Speed controllers Control unit Transformer Clamps
Technical data
Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]
Dimensions [mm]
Model
ØD B L L1
VENTS 100 LD Auto 99.5 205 110 60
VENTS 125 LD Auto 125 205 118 65
VENTS 150 LD Auto 150 240 137 81
L
L1
D
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.
Accessories
Air ducts Grilles and hoods Back valves Speed controllers Control unit Transformer Clamps
Pressure, ΔP [Pa]
Pressure, ΔP [Pa]
VENTS 100 LD Light VENTS 125 LD Light VENTS 150 LD Light
VENTS 100 LD Light turbo VENTS 125 LD Light turbo VENTS 150 LD Light turbo
VENTS 100 LD Light 12 VENTS 125 LD Light 12 VENTS 150 LD Light 12
Technical data
Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]
L
L1
D
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.
Accessories
Backdraft
Air ducts Grilles and hoods damper Speed controllers Clamps
Technical data
Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]
Dimensions [mm]
Model
ØD B H L L1
VENTS 100 LD Fresh time 100 152 120 135 40
VENTS 125 LD Fresh time 125 175 140 145 44
VENTS 150 LD Fresh time 150 205 165 164 46
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.
Accessories
Backdraft
Air ducts Grilles and hoods damper Speed controllers Clamps
Technical data
Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]
Dimensions [mm]
Model
ØD B L L1
VENTS 100 Modern 100 170 130 35
VENTS 125 Modern 125 196 139 38
VENTS 150 Modern 150 226 157 39
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.
Accessories
Air ducts Grilles and hoods Back valves Speed controllers Control unit Transformer Clamps
VENTS 100 Modern Auto VENTS 125 Modern Auto VENTS 150 Modern Auto
VENTS 100 Modern Auto turbo VENTS 125 Modern Auto turbo VENTS 150 Modern Auto turbo
VENTS 100 Modern Auto press VENTS 125 Modern Auto press VENTS 150 Modern Auto press
VENTS 100 Modern Auto 12 VENTS 125 Modern Auto 12 VENTS 150 Modern Auto 12
Technical data
Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]
Dimensions [mm]
Model
ØD B H L L1
VENTS 100 Modern Auto 99.5 196 196 117 60
VENTS 125 Modern Auto 125 220 220 124 65
VENTS 150 Modern Auto 150 242 242 139 81
L
L1
H
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.
Accessories
Air ducts Grilles and hoods Back valves Controllers Control unit Transformer Clamps
Pressure, ΔP [Pa]
Pressure, ΔP [Pa]
VENTS 100 Domino VENTS 125 Domino VENTS 150 Domino
VENTS 100 Domino turbo VENTS 125 Domino turbo VENTS 150 Domino turbo
Technical data
Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]
Dimensions [mm]
Model
H B ØD L L1
VENTS 100 Domino 170 170 99.5 138 96
VENTS 125 Domino 196 196 124.5 143 101
VENTS 150 Domino 226 226 149.5 161 118
L
L1
H
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.
Z1 Z2 Z3 Z4 Z5 Z6
Accessories
Backdraft
Air ducts Grilles and hoods damper Speed controllers Clamps
Technical data
Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]
Dimensions [mm]
Model
ØD B H L L1
VENTS 100 Z 100 181 120 143 56
VENTS 125 Z 125 208 140 143 56
VENTS 150 Z 150 231 165 166 56
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.
Accessories
Backdraft
Air ducts Grilles and hoods damper Speed controllers Clamps
Technical data
Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]
Dimensions [mm]
Model
ØD B H L L1
VENTS 100 Z star 100 181 120 148 56
VENTS 125 Z star 125 204 140 154 56
VENTS 150 Z star 150 231 165 171 56
VENTS 100 Z star T 98 183 122 151 65
VENTS 100 Z star TH 98 183 122 151 65
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.
Motor
• By the electronic control unit BU-1-60 (see
Electrical Accessories). The control unit is supplied
separately.
• Reliable and low-watt electric motor.
• Designed for continuous operation and
Mounting features
requires no maintenance.
• Equipped with overheating protection. • The fan is mounted directly into the ventilation
shaft.
Accessories
Backdraft
Air ducts Grilles and hoods damper Speed controllers Clamps
Technical data
Dimensions [mm]
Model
ØD B H L L1
VENTS 100 Vitro 100 183 120 145 58
VENTS 125 Vitro 125 205 140 146 58
VENTS 150 Vitro 150 233 165 169 58
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.
Vitro star 1 Vitro star 2 Vitro star 3 Vitro star 4 Vitro star 5 Vitro star 6
Accessories
Backdraft
Air ducts Grilles and hoods damper Speed controllers Clamps
Technical data
Dimensions [mm]
Model
ØD B H L L1
VENTS 100 Vitro star 100 183 120 151 58
VENTS 100 Vitro star T 98 183 122 151 65
VENTS 100 Vitro star TH 98 183 122 151 65
VENTS 125 Vitro star 125 205 140 156 58
VENTS 150 Vitro star 150 233 165 173 58
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.
sensor with the threshold value from 60 to 90 %. • For 12 V low-voltage motor fan connection
to 220 V/50 Hz power mains use the step-down
XV – equipped with a pull cord switch. transformer TRF 220/12-25 that is available upon
separate order.
Accessories
Backdraft
Air ducts Grilles and hoods damper Speed controllers Clamps
Technical data
Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]
Dimensions [mm]
Model
ØD B H L L1
VENTS 100 X 100 152 120 125 30
VENTS 125 X 125 177 140 143 42
VENTS 150 X 150 205 165 160 42
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.
• The casing and the impeller are made of high- • The fan is controlled by a room light switch. It
quality durable ABS plastic, UV resistant. is not included in the delivery package.
• The intellectual impeller design makes the fan • Speed control is possible through a thyristor
efficiency high and the service life long. speed controller (see Electrical Accessories).
Several fans may connected to the same controller.
• A 2 W LED lamp is integrated into the fan Speed controllers can not be connected to the
casing. fans with T, TH, TP, VT, VTH modification.
• Protection rating IP24. Automatic:
Motor
• By the electronic control unit BU-1-60 (see
Electrical Accessories). The control unit is supplied
separately.
• Reliable and low-watt electric motor.
• Designed for continuous operation and
Mounting features
requires no maintenance.
• Equipped with overheating protection. • The fan is mounted directly into the ventilation
shaft.
Accessories
Backdraft
Air ducts Grilles and hoods damper Speed controllers Clamps
Technical data
Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]
Dimensions [mm]
Model
ØD B H L L1
VENTS 100 X star 100 152 120 131 36
VENTS 125 X star 125 177 140 143 42
VENTS 150 X star 150 205 165 160 42
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.
• Reliable motor with low energy demand. • The fan is mounted directly into the ventilation
shaft.
• Designed for continuous operation and
requires no maintenance. • Flexible duct connection is recommended in
case of the remote ventilation shaft location. The
• Equipped with overheating protection. air duct is connected to the fan exhaust flange
through a clamp.
Exhaust axial fan Modifications and options
• Fixing to wall with screws.
with integrated light source. Lumis 100 K – the fan is equipped with a • Suitable for ceiling mounting.
Air flow back valve to prevent air back drafting.
up to 115 m3/h
Lumis 100 L – the motor is equipped
Application with ball bearings for long service
life (appr. 40 thousand hours) and
• Continuous or periodic exhaust ventilation fan mounting at any angle. The bearings are
of bathroom, showers, kitchens and other utility maintenance-free and contain enough grease for
spaces. the entire operating period.
• Ventilation shaft mounting or duct connec- Lumis 100 turbo – high-powered
tion. motor.
• Low to medium air flow motion for short dis-
tances at low air resistance.
• Compatible with Ø 100 mm air ducts.
Accessories
Speed
Air ducts Grilles and hoods Back valves controllers Control unit Clamps
Technical data
Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]
Dimensions [mm]
Model
Ø D1 ØD L L1
VENTS Lumis 100 178 99.4 133.5 46
VENTS Lumis 100 turbo 178 99.4 133.5 46
L
L1
D
D1
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.
Axial window fan with automatic louver shutters for exhaust ventilation with the capacity up to
345 m3/h.
Axial window reverse fan with automatic louver shutters for exhaust ventilation with the capacity
up to 202 m3/h.
Axial window fan with automatic louver shutters for exhaust ventilation with the capacity up to
232 m3/h. The fan is equipped with an external hood.
Axial window fan with a backdraft damper for exhaust ventilation with the capacity up to 232
m3/h. The fan is equipped with an external hood.
VENTS VV Series
Axial window fan with automatic louver shutters for exhaust ventilation with the capacity up to
455 m3/h. Flange mounting sizes 180 mm and 230 mm.
Axial window fan with automatic louver shutters and reversing motor for exhaust or supply
ventilation with the capacity up to 455 m3/h. Flange mounting sizes 180 mm and 230 mm.
Back side of MAO2 fan Fan OFF – louver shutters CLOSED Fan ON – louver shutters OPEN
Accessories
Speed controllers
Technical data
Power
Frequency Voltage Maximum air Sound Pressure SEC Weight
Model Consumption Tok, A R.p.m.
[Hz] [V] flow [m3/h] Level at 3 m [dBA] class [kg]
[W]
VENTS 125 MAO1 50/60 220-240 22 0.1 2400 185 35 E 1.15
VENTS 125 MAO1 turbo 50/60 220-240 24 0.105 2400 232 37 E 1.31
VENTS 125 MAO1 12 50/60 12 16 1.7 2300 165 34 E 1.13
VENTS 125 MAO2 50/60 220-240 22 0.1 2400 185 35 E 1.14
VENTS 125 MAO2 turbo 50/60 220-240 24 0.105 2400 232 37 E 1.24
VENTS 125 MAO2 12 50/60 12 16 1.7 2300 165 34 E 1.12
VENTS 150 MAO1 50 220-240
VENTS 150 MAO1 26 0.13 2400 295 41 E 1.53
60 220
(220 V/60 Hz)
VENTS 150 MAO1 turbo 50 220-240
VENTS 150 MAO1 turbo 29 0.13 2400 345 43 E 1.67
60 220
(220 V/60 Hz)
Overall dimensions
Dimensions [mm]
Model
ØD B H H1 L1 L2
Mounting examples
MAO1 MAO2
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.
Fan on – louver
shutters OPEN
Technical Data
Power Sound
Frequency Voltage Current Maximum air SEC Weight
Model Mode Speed Consumption R.p.m. Pressure Level
[Hz] [V] [A] flow [m3/h] class [kg]
[W] at 3 m [dBA]
Overall dimensions
Dimensions [mm]
Model
ØD B H H1 L1 L2
Mounting examples
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.
• The intellectual impeller design makes the fan • The fan is controlled by the built-in pull cord
efficiency high and the service life long. switch V.
• The fan and motor are specially designed for • Speed control is possible through a thyristor
silent operation. speed controller (see Electrical Accessories).
Several fans may connected to the same controller.
• Fan is equipped with a backdraft damper for Speed controllers can not be connected to the
back flow preventing. fans with T, TH, TP, VT, VTH modification.
• The fan is equipped with an external hood. Automatic:
• Protection rating IP24.
• By the electronic control unit BU-1-60 (see
Electrical Accessories). The control unit is supplied
Motor separately.
Axial window fans • Reliable and low-watt electric motor. • By the timer T (the built-in turn-off delay timer
for exhaust ventilation enables the fan operation within 2 to 30 minutes
• Designed for continuous operation and
after the fan switching off ).
with the capacity up to 232 m3/h requires no maintenance.
• Equipped with overheating protection. Mounting features
Application • The fan is mounted directly into the window
Modifications and Options opening.
• Continuous or periodic exhaust ventilation M1OK2 L – the motor is equipped with • For 12 V low-voltage motor fan connection
of bathroom, showers, kitchens and other utility to 220 V/50 Hz power mains use the step-down
ball bearings for long service life (appr.
spaces. transformer TRF 220/12-25 that is available upon
40 thousand hours) and fan mounting
• For mounting in windows. at any angle. The bearings are maintenance- separate order.
free and contain enough grease for the entire
operating period.
M1OK2 turbo – high-powered motor.
M1OK2 VT – equipped
with a pull cord switch and
a regulated timer with the
operating time adjustable from 2 to 30 minutes.
Accessories
Speed controllers
Technical data
Dimensions [mm]
Model
ØD B H H1 L1 L2
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.
Motor
Accessories
Speed controllers
Technical data
Dimensions [mm]
Model
A B C D
VENTS VV 180 230 65 87 177
VENTS VVR 180 230 65 87 177
VENTS VV 230 295 74 85 237
VENTS VV 230 295 74 85 237
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.
VENTS CF Series
Centrifugal single-speed fans with a built-in filter for exhaust ventilation with the air flow of up to
122 m3/h. Compatible with Ø 100 mm air ducts.
Centrifugal three-speed fans with a built-in filter for exhaust ventilation with the air flow of up to 90
m3/h. Equipped with a three speed switch. Compatible with Ø 100 mm air ducts.
Centrifugal fans
VENTS CF3 Series page
Air flow up to 90 m3/h 164
bearings for long service life (appr. • Flexible duct application is recommended in
40 thousand hours) and mounted on specially case of remote location of the ventilation shaft.
designed vibration mounting. The bearings are The air duct is connected to the fan exhaust flange
maintenance-free and contain enough grease for through a clamp.
the entire operating period. • Fixed to wall by self-tapping screws or fixing
CF 100 T – equipped with a regulated brackets.
timer with the operating time from 2 to • Suitable for ceiling mounting.
30 minutes. • For 12 V low-voltage motor fan connection
CF 100 TH – equipped with a to 220 V/50 Hz power mains use the step-down
timer with the operating time transformer TRF 220/12-25 that is available upon
from 2 to 30 minutes and a separate order.
humidity sensor with the threshold value from 60
to 90 %.
CF 100 V – equipped with a pull cord
switch.
Accessories
Air ducts Grilles and hoods Speed controllers Clamps Replaceable filters
Technical data
Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.
• The casing and the impeller are made of high- • The fan is controlled by the speed switch P3-
quality durable ABS plastic, UV resistant. 1-300 delivered as a standard (CF3 P3 model).
Automatic:
• The easy to use removable grille with a filter
element protects the fan internal components • By the electronic control unit BU-1-60 (see
against grease and dust penetration and makes it Electrical Accessories). The control unit is supplied
suitable for kitchen exhaust ventilation. separately.
• The basic CF3 fan modification includes a dust Mounting features
filter. Aluminium grease filter configurations are
also available (CFA3 model). • Suitable for external or built-in mounting.
• The centrifugal fan impeller has forward- • Flexible duct application is recommended in
curved blades for high pressure and low noise case of remote location of the ventilation shaft.
levels. The air duct is connected to the fan exhaust flange
through a clamp.
• Equipped with a gravitational backdraft
damper for air back flow prevention. • Fixed to wall by self-tapping screws or fixing
brackets.
• Protection rating IP24.
• Suitable for ceiling mounting.
Centrifugal fans Motor
for exhaust ventilation with the
• Reliable and low-watt single-phase three-
capacity up to 90 m3/h speed electric motor.
• Motor equipped with ball bearings mounted
on specially designed vibration dampers.
Application
• Designed for continuous operation and
• Continuous or periodic exhaust ventilation requires no maintenance.
of bathroom, showers, kitchens and other utility
spaces.
• Equipped with overheating protection.
Accessories
Air ducts Grilles and hoods Speed controllers Clamps Replaceable filters
Dimensions [mm]
Model
ØD B H L L1 L2 L3
VENTS CF3 100 100 180 195 132 59 73 26
Technical data
Mounting examples
Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.
KO series • To prevent air back drafting. • Back valve is mounted on a fan with special
fasteners provided on the fan spigot.
• Does not disturb passive indoor ventilation.
• For domestic fan series VENTS M, M1, D, S, M3, X, X1,
LD, LD Fresh time, Silenta-M, Silenta-S, Modern, Vitro
star, Z star, X star.
• Designed for connection to Ø 100, 125 and
150 mm air ducts.
Design
• Casing made of ABS plastic and the membrane is
made of special light polymer.
Overall dimensions
Dimensions [mm]
Model
ØD a
KO 100 100 14
KO 120 120 14
KO 125 125 14
KO 150 150 14
Mounting
1
2
1. Fan.
Inner side view.
2. Single window glass.
3. Window flange.
Overall dimensions
Dimensions [mm]
Model
ØD Ø D1 a
FO 100 100 120 25
FO 125 125 147 25
FO 150 150 172 25
• MAO Series
• CF Series
Direct air exhaust through the wall Exhaust ventilation through the ceiling and wall
Air exhaust through the ventilation shaft Air exhaust through the wall. For warm air distribution from a
room with a fireplace to adjacent premises
Wiring diagram for the fans equipped Wiring diagram for the fans Wiring diagram for the fans equipped
with a built-in switch without built-in switch with a timer / timer, humidity sensor
and a built-in switch
Wiring diagram for the fans equipped Wiring diagram for the fans with Wiring diagram for the fans with
with a timer / timer with a humidity a light lamp. a light lamp. Parallel activation
sensor without built-in switch Separate activation of the fan and the of the fan and the built-in lamp.
built-in lamp.
Wiring diagram for the fans with Wiring diagram for the fans
with a light lamp and grounding. Wiring diagram for the fans
an light lamp and grounding. Separate
Parallel switching of the fan with grounding
activation of the fan and the built-in lamp.
and the built-in lamp.
* – only for fans designed for 12 V rated voltage (specified on the fan casing and packing).
S, S1, S2 – external switches.
BACK VALVE
Transformers page
188
Control unit Application • «Dark mode»: The control unit switches the fan on
after the light is off. The operation duration is adjusta-
BU-1-60 • Automation and control of residential fan opera- ble from 5 sec to 30 min and the photosensor thresh-
tion. It includes automatic controls as timer, humidity
old is set by the regulator.
sensor, photosensor and motion sensor. All these op-
tions can be used in any combination. • «Light mode»: The control unit switches the fan
on after the light is on. As light is off the fan con-
Design tinues operating and turns off as the turn-off delay
timer requires from 5 sec to 30 min. If the light is on
• The control unit casing is made of high-quality more than 60 minutes the fan switches off. The pho-
plastic. tosensor threshold is set by the control unit.
• The front panel is equipped with light indicators • The motion sensor responds to human motion
that display the current operating mode. in the sensitivity area and switches the fan automat-
• Automatic operation with selected mode is possi- ically on. When motion is not registered the control
ble. The switches are used to activate required opera- unit switches the fan off as the turn-off delay timer
tion modes depending on a specific application. The requires from 5 sec to 30 min. Use of the motion sen-
control units are available in several modifications: sor makes the fan control easy and is especially suit-
• Turn-off delay timer keeps the fan running for able for periodically visited premises. The sensitivity
a set time period after turning the built-in or exter- area is 4 m max. and the detection angle up to 100°.
nal switch off that provides extra ventilation in the
premise. The control unit switches the fan off from 5 Mounting
sec to 30 minutes. • The control unit is designed for indoor installation,
• Cyclic timer operation: the cyclic operation both close to the fan and remote. The installation place is
mode allows switching the fan on and off with set selected with respect to the furniture location and walk-
time intervals. Operation or standstill duration is ad- ing routes.
justed from 5 sec to 30 min. The fan switches on and
operates within pre-set time period followed by a
pause according to timer settings. After that the cy-
cle is renewed.
• Humidity sensor switches the fan on as the hu-
midity level in the premise increases above the set
threshold. As it drops back the control unit switches
the fan off. Humidity threshold is user-adjustable.
• Built-in photosensor is sensitive to illumination in
the room and switches the fan automatically on.
S1 X Options
LT humidity motion
L L Model switch timer photosensor
sensor sensor
M
220-240 V B VENTS BU-1-60
M
N N VENTS BU-1-60 TF
VENTS BU-1-60 THF
VENTS BU-1-60 THPF
S1 S2 X
LT
L L Technical data
M
220-240 V B BU-1-60
M
N N Voltage [V] at 50 Hz 1~ 230
Max. load power [W] 60
Wiring diagram of the control unit
Maximum load current [A] 0.3
Overall dimensions LxBxH [mm] 151x46x27
B – fan; Maximum ambient temperature [oC] +40
S1 – automatic circuit breaker;
S2 – external switch; Protection IP34
X – input terminal block BU. Weight [kg] 0.075
SRS-1 • Applied in ventilation systems for turning the • The controller is designed for indoor mount-
fans on/off and speed control of single-phase ing into standard round electric junction boxes.
voltage controlled fan motors. Several fans can
be connected to one speed controller if their to-
tal current does not exceed the maximum con-
troller current.
Design
• The casing is made of plastic and the sensor
panel is made of hardened glass. The sensor pan-
el has On/Off button for speed control from min-
imum to maximum. The set speed level is dis-
played on the LED display. The speed controller
has high control accuracy.
Technical data:
SRS-1
Voltage [V/50/60 Hz] 230
Maximum load current [A] 1
Cable cross section 0.35 up to 1 mm2
Temperature range [°C] from -10 up to +45
Humidity range 5 % up to 80 % (no condensation)
Service life 100 000 switching operations
Ingress Protection IP30
Weight [g] 138
110-240 V,
50/60 Hz
L
L
Out1
In
Overall dimensions:
86 31
21 58
11
R1,5
OUT OUT OUT OUT IN
L4 L3 L2 L1 L
4
86
62
52
Technical data
RS-1-300
Voltage [V] at 50 Hz 1~ 230
Rated current [A] 1.5
Overall dimensions LxBxH [mm] 95x85x60
Maximum ambient temperature [°C] 40
Protection IP40
Weight [kg] 0.11
MKV-2
Technical data
RS-1-400
Voltage 50/60 Hz [V] 1~ 230
Rated current [A] 1.8
Overall dimensions LxBxH [mm] 78x78x63
Maximum ambient temperature [°C] 35
Protection IP40
Weight [kg] 0.11
Modifications
• RS-1-0,5 – a speed controller without a
mounting junction box.
• RS -1-0,5 N – a speed controller, completed with
a surface mounting junction box.
• RS-1-0,5 V – a speed controller, completed with
a flush mounting junction box.
• RS-1-0,5 NV – a speed controller, completed
with surface and flush mounting junction boxes.
Technical data
RS-1-0,5
Voltage 50/60 Hz [V] 1~ 230
Rated current [A] 0.5
Overall dimensions LxBxH [mm] 78x78x63
Maximum ambient temperature [°C] 35
Protection IP40
Weight [kg] 0.11
• The controller is featured with high efficiency • The casing design allows mounting the
and control accuracy. controller on the wall (N modification) or inside the
wall (V modification).
• Regulation starts from the minimum to the
maximum voltage value. The maximum speed
produces the smoothest rotation.
Technical data
RS-1 N (V) RS-1.5 N (V) RS-2 N (V) RS-2,5 N (V)
Voltage [V] at 50 Hz 1~ 230 1~ 230 1~ 230 1~ 230
Rated current [A] 1.0 1.5 2.0 2.5
Overall dimensions LxBxH [mm] 162x80x70 162x80x70 162x80x70 162x80x70
Maximum ambient temperature [oC] 40 40 40 40
Protection IP30 IP30 IP30 IP30
Weight [kg] 0.3 0.3 0.3 0.3
• Start the controller by pressing the button. • The versatile casing design allows fan mounting
on the wall or inside the wall.
• Regulation starts from the minimum to the
maximum voltage value. The maximum speed • Suitable for installation inside the round junction
produces the smoothest rotation. boxes.
Technical data
RS-0,5-PS RS-1,5-PS RS-2,5-PS RS-4,0-PS
Voltage [V] at 50 Hz 1~ 230 1~ 230 1~ 230 1~ 230
Minimum current [A] 0.1 0.15 0.25 0.4
Maximum current [A] 0.5 1.5 2.5 4.0
Overall dimensions LxBxH [mm] 82x82x65 82x82x65 82x82x65 82x82x65
Maximum ambient temperature [oC] 35 35 35 35
Protection IP44 IP44 IP44 IP44
Weight [kg] 0.23 0.24 0.29 0.36
RSA-0,3 • RSA speed controller is used for air flow • For overload protection the controller is
control of single-speed fans with low power equipped with a replaceable melting fuse.
consumption by step speed control of electric
motors. Several fans can be controlled from the Mounting
same unit in case the total consumption current
does not exceed the permissible controller
• Transformer speed controller is designed
for indoor installation. Provide sufficient air
current value. circulation for cooling of the internal circuits and
do not install the speed controller above heating
Design equipment.
• The controller casing is made of high-quality
plastic.
• Speed controller has four speeds with output
frequency 160 V – 180 V – 200 V – 230 V. Speed
controller is equipped with on/off light indicator
and control knob for speed switch.
Technical data
RSA-0,3
Voltage [V] at 50 Hz 1~ 230
Output power, no more [VA] 60
Maximum load current [A] 0.3
Overall dimensions LxBxH [mm] 162x80x70
Maximum ambient temperature [oC] +40
Protection IP30
Weight [kg] 0.65
Speed control provides not only the best ventilation mode for periodically visited premises but
considerable reduction of energy consumption.
B – fan;
S – speed controller.
Sensor speed switch Application vated speed button to turn the ventilation unit off. The ac-
tivated speed button glows blue.
SP3-1 • Applied in ventilation systems for turning the fans
on/off and speed switch of multi-speed fan motors.
Mounting
Design and control • The speed switch is designed for indoor
mounting into special surface mounting box MKN-5
• The casing is made of plastic and is equipped (upon special order) or flush mounting junction box
with a sensor panel made of hardened glass. The
MKV-1 (included).
sensor panel has three speed switch buttons. Press
a respective speed button to activate a required
speed of a connected ventilation unit. Press an acti-
Technical data
SP3-1
Voltage [V/50/60 Hz] 110-240
Maximum load current [A] 1
Cable cross section 0.35 up to 1 mm2
Temperature range [°C] from -10 up to +45
Humidity range 5 % up to 80 % (no condensation)
Service life 100 000 switching operations
Ingress Protection IP30
Weight [g] 138
Overall dimensions:
SURFACE MOUNTING JUNCTION BOX
View on mounting side
MKN-5
Technical data
P2-1-300 P3-1-300
Voltage [V] at 50 Hz 1~ 230 1~ 230
Rated current [A] 3.0 3.0
Number of speeds 2 3
Overall dimensions LxBxH [mm] 88x88x51 88x88x51
Maximum ambient temperature [oC] 40 40
Protection IP40 IP40
Weight [kg] 0.13 0.13
diagram 1 diagram 4
The fan can be manually switched ON The fan can be manually switched ON
to one of the three required speeds to one of three speeds by means of the
or switched OFF by means of external external S speed switch as P2-1-300.
speed switch as P3-1-300. When switching the fan ON the light is
switched in parallel ON. The fan can be
switched OFF with parallel switching
the light OFF. The fan operates both
with light or without it.
diagram 2
The fan can be manually switched ON
to one of three speeds by means of such
external S speed switch as P3-1-300. FLUSH MOUNTING JUNCTION BOX
When switching the fan ON the light is
switched in parallel ON. The fan can be
switched OFF with parallel switching
the light OFF. The fan operates both
with light or without it.
diagram 3
The fan can be manually switched ON
to one of the two required speeds or
switched OFF by means of the external MKV-2
speed switch as P2-1-300.
Technical data
P2-5,0 P3-5,0 P5-5,0
Voltage [V] at 50 Hz 1~ 230 1~ 230 1~ 230
Rated current [A] 5.0 5.0 5.0
Number of speeds 2 3 5
Overall dimensions LxBxH [mm] 162x80x70 162x80x70 162x80x70
Maximum ambient temperature [oC] 40 40 40
Protection IP30 IP30 IP30
Weight [kg] 0.25 0.25 0.25
B – fan
S – switch
P2-5,0 N(V) P3-5,0 N(V) P5-5,0 N(V)
Technical data
RT-10
Voltage 50/60 Hz [V] 1~ 220-240
Overall dimensions LxBxH [mm] 84x84x35
Maximum ambient temperature [ C] o
40
Protection IP40
Fan operates until it reaches the pre-set Fan starts operation as the temperature reaches
temperature threshold the threshold value set by the thermostat.
fig. 1 fig. 2
Regulator connections
• The display shows current and set indoor air • The recommended installation height is 1.5 m
temperature, set speed and a selected operation above the floor level.
mode. The temperature controller may be set for • The installation place must not be close to
cooling, heating or auto mode. windows, doors and heating or cooling equip-
ment.
• The fan speed is set manually by pressing the
control buttons. • Wall flush mounting in the junction box
MKV-1 (available upon separate order).
• Automatic control of low/medium/high
speed, depending on indoor air temperature.
Technical data
RTS-1-400 RTSD-1-400
Voltage [V] at 50 Hz 1~ 230 1~ 230
Rated current [A] 2.0 2.0
Number of speeds 3 3
Temperature range °C +10…+30 +10…+30
Overall dimensions LxBxH [mm] 88x88x51 88x88x51
Maximum ambient temperature [oC] 40 40
Protection IP40 IP40
Remote control no yes
• Operation in heating mode: 30 minutes after activation of the night mode the indoor air
temperature drops by 1 °C and by one more 1 °C in the next hour. In the next hour the air temperature
drops by 1 °C more and remains constant for the next 5 hours. After turning the timer off the air
temperature reaches the initial value.
• Operation in cooling mode: 30 minutes after activation of the night mode the indoor air
temperature increases by 1 °C and by one more 1 °C in the next hour and remains constant for the next
6 hours. After turning the timer off the air temperature drops down to the initial value.
Temperature controller
wiring options
MKV-1
Technical data
TRF-220/12-25
Voltage [V] at 50 Hz 1~ 230
Output voltage [V] / 50 Hz 12
Max. load power, no more 16 (25 VA)
Maximum load current [A] 2.0
Transformer 91x58x62
Overall dimensions LxBxH [mm]
Terminal box 110x40x40
Maximum ambient temperature [oC] +40
Protection IP40
Weight [kg] 0.8
Technical data
TRF-220/12-25 K
Voltage [V] at 50 Hz 1~ 230
Output voltage [V] / 50 Hz 12
Max. load power, no more 16 (25VA)
Maximum load current [A] 2.0
Overall dimensions LxBxH [mm] 80x162x63
Maximum ambient temperature [oC] +40
Protection IP30
Weight [kg] 0.85
TRF-220/12-25 K TRF-220/12-25 KV
MV 100 Application
Series • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.
• Used for correct air flow distribution in premises.
• Wall or ceiling mounting.
Design
• Made of quality and durable plastic.
• Multi-element structure. The internal part is fixed to the base with latches for easy cleaning without
dismantling.
• Screw fixing.
• The grille has slanted vanes.
Colour modifications
Modifications
• Fitted with a round connecting flange for mounting with Ø100 mm air duct.
• Equipped with a movable flap for air flow regulation.
• Air pass is regulated with a tilt wand or pull cords.
• Suitable for direct mounting with VENTS VKO 100 fan.
• MV 100 VRs – model with a round flange, air flow regulator and a protecting
insect screen.
• Equipped with a multi-section connecting flange for mounting with Ø100, 125 mm
or 55x110 mm air duct.
• MV 100 VUs – model with a multi-section flange and a protecting insect screen.
MV 100 VUR – model with a multi-section flange and air flow regulator (VUR)
• Equipped with a multi-section connecting flange for mounting with Ø100, 125 mm
or 55x110 mm air duct.
• Equipped with a movable flap for air flow regulation.
• Air pass is regulated with a tilt wand or pull cords.
• MV 100 VURs – model with a multi-section flange, air flow regulator and a protecting
insect screen.
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2] Fig. no.
B H L L1 Flange (D)
MV 101 Application
Series • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.
• Used for correct air flow distribution in premises.
• Wall or ceiling mounting.
Design
• Made of quality and durable plastic.
• Multi-element structure. The internal part is fixed to the base with latches for easy cleaning without
dismantling.
• Screw fixing.
• The grille has straight vanes to increase air pass.
Colour modifications
Modifications
• Fitted with a round connecting flange for mounting with Ø 100 mm air duct.
• Suitable for direct mounting with VENTS VKO 100 fan.
• MV 101 Vs – model with a round flange and a protecting insect screen.
• Fitted with a round connecting flange for mounting with Ø100 mm air duct.
• Equipped with a movable flap for air flow regulation.
• Air pass is regulated with a tilt wand or pull cords.
• Suitable for direct mounting with VENTS VKO 100 fan.
• MV 101 VRs – model with a round flange, air flow regulator and a protecting insect
screen.
• Equipped with a multi-section connecting flange for mounting with Ø 100, 125 mm or
55x110 mm air duct.
• MV 101 VUs – model with a multi-section flange and a protecting insect screen.
MV 101 VUR – model with a multi-section flange and air flow regulator (VUR)
• Equipped with a multi-section connecting flange for mounting with Ø 100, 125 mm or
55x110 mm air duct.
• Equipped with a movable flap for air flow regulation.
• Air pass is regulated with a tilt wand or pull cords.
• MV 101 VURs – model with a multi-section flange, air flow regulator and a protecting
insect screen.
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2] Fig. no.
B H L L1 Flange (D)
MV 120 Application
Series • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.
• Used for correct air flow distribution in premises.
• Wall or ceiling mounting.
Design
• Made of quality and durable plastic.
• Multi-element structure. The internal part is fixed to the base with latches for easy cleaning without
dismantling.
• Screw fixing.
• The grille has slanted vanes.
Colour modifications
Modifications
• Fitted with a round connecting flange for mounting with Ø 125 mm air duct.
• Suitable for direct mounting with VENTS VKO 125 fan.
• MV 120 Vs – model with a round flange and a protecting insect screen.
• Fitted with a round connecting flange for mounting with Ø 125 mm air duct.
• Equipped with a movable flap for air flow regulation.
• Air pass is regulated with a tilt wand or pull cords.
• Suitable for direct mounting with VENTS VKO 125 fan.
• MV 120 VRs – model with a round flange, air flow regulator and a protecting insect
screen.
MV 120 VNR – model with a flange with various diameters and air flow regulator (VNR)
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2] Fig. no.
B H L L1 D
MV 121 Application
Series • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.
• Used for correct air flow distribution in premises.
• Wall or ceiling mounting.
Design
• Made of quality and durable plastic.
• Multi-element structure. The internal part is fixed to the base with latches for easy cleaning without
dismantling.
• Screw fixing.
• The grille has straight vanes to increase air pass.
Colour modifications
Modifications
• Fitted with a round connecting flange for mounting with Ø 125 mm air duct.
• Suitable for direct mounting with VENTS VKO 125 fan.
• MV 121 Vs – model with a round flange and a protecting insect screen.
• Fitted with a round connecting flange for mounting with Ø 125 mm air duct.
• Equipped with a movable flap for air flow regulation.
• Air pass is regulated with a tilt wand or pull cords.
• Suitable for direct mounting with VENTS VKO 125 fan.
• MV 121 VRs – model with a round flange, air flow regulator and a protecting insect
screen.
• Fitted with a round connecting flange with various diameters for mounting with
Ø 100/110/120/130/150 mm air duct.
• MV 121 VNs – model with a round flange with various diameters and a protecting
insect screen.
MV 121 VNR – model with a flange with various diameters and air flow regulator (VNR)
• Fitted with a round connecting flange with various diameters for mounting with
Ø 100/110/120/130/150 mm air duct.
• Equipped with a movable flap for air flow regulation.
• Air pass is regulated with a tilt wand or pull cords.
• MV 121 VNRs – model with a round flange with various diameters, air flow
regulator and a protecting insect screen.
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2] Fig. no.
B H L L1 D
MV 125 Application
Series • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.
• Used for correct air flow distribution in premises.
• Wall or ceiling mounting.
Design
• Made of quality and durable plastic.
• Multi-element structure. The internal part is fixed to the base with latches for easy cleaning without
dismantling.
• Fixing with screw or lugs depending on modification.
Colour modifications
Modifications
• Screw fixing.
• MV 125 s – model with a protecting screen and screw fixing.
• MV 125 M – model with fixing lugs.
• MV 125 Ms – model with fixing lugs and a protecting insect screen.
• Screw fixing.
• Equipped with four-element connecting flange with adjustable diameter for
connection to Ø 100-150 mm round air duct.
• MV 125 VDS – grille model with screw fixing and a protecting insect screen.
• MV 125 VDM – grille model with fixing lugs.
• MV 125 VDMs – grille model with fixing lugs and a protecting insect screen.
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2] Fig. no.
H B L L1 H1 B1 D
MV 125 251 182 16 – 226 157 – 0.0127 1, 2
MV 125 VD 251 182 16 41 226 157 100-150 0.0127 1, 3
MV 125-1 Application
Series • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.
• Used for correct air flow distribution in premises.
• Wall or ceiling mounting.
Design
• Made of quality and durable plastic.
• Single-element structure. Modification may include a protecting insect screen.
• Fixing with glue or silicon.
Colour modifications
Modifications
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2]
H B L
MV 125-1 238 170 8 0.0127
MV 126 Application
Series • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.
• Used for correct air flow distribution in premises.
• Wall or ceiling mounting.
Design
• Made of quality and durable plastic.
• Multi-element structure. The internal part is fixed to the base with latches for easy cleaning
without dismantling.
• Fixing with screws or lugs depending on grille modification.
Colour modifications
Modifications
• Screw fixing.
• MV 126 s – model with screw fixing and a protecting insect screen.
• MV 126 M – model with fixing lugs.
• MV 126 Ms – model with fixing lugs and a protecting insect screen.
• Screw fixing.
• Equipped with four-element connecting flange with adjustable diameter
for connection to Ø 100-150 mm round air duct.
• MV 126 VDs – model with screw fixing and a protecting insect screen.
• MV 126 VDM – model with fixing lugs.
• MV 126 VDMs – model with fixing lugs and a protecting insect screen.
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2] Fig. no.
H B L L1 H1 B1 D
MV 126 251 182 19.5 – 226 157 – 0.018 1, 2
MV 126 VD 251 182 19.5 45 226 157 100-150 0.018 1, 3
MV 126-1 Application
Series • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.
• Used for correct air flow distribution in premises.
• Wall or ceiling mounting.
Design
• Made of quality and durable plastic.
• Single-element structure. Modification may include a protecting insect screen.
• Fixing with glue or silicon.
Colour modifications
Modifications
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2]
H B L
MV 126-1 238 170 13.5 0.018
MV 150 V Application
Series • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.
• Used for correct air flow distribution in premises.
• Wall or ceiling mounting.
Design
• Made of quality and durable plastic.
• Multi-element structure. The internal part is fixed to the base with latches for easy cleaning without
dismantling.
• Screw fixing.
• The grille has slanted vanes.
Colour modifications
Modifications
• Fitted with a round connecting flange for mounting with Ø 150 mm air duct.
• Suitable for direct mounting with VENTS VKO 150 fan.
• MV 150 Vs – model with a round flange and a protecting insect screen.
MV 150 VR – model with a round flange and air flow regulator (VR)
• Fitted with a round connecting flange for mounting with Ø 150 mm air duct.
• Equipped with a movable flap for air flow regulation.
• Air pass is regulated with a tilt wand or pull cords.
• Suitable for direct mounting with VENTS VKO 150 fan.
• MV 150 VRs – model with a round flange, air flow regulator and a protecting insect
screen.
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2] Fig. no.
B H L L1 D
Fig. 1 Fig. 2
MV 151 V Application
Series • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.
• Used for correct air flow distribution in premises.
• Wall or ceiling mounting.
Design
• Made of quality and durable plastic.
• Multi-element structure. The internal part is fixed to the base with latches for easy cleaning without
dismantling.
• Screw fixing.
• The grille has straight vanes to increase air pass.
Colour modifications
Modifications
• Fitted with a round connecting flange for mounting with Ø 150 mm air duct.
• Suitable for direct mounting with VENTS VKO 150 fan.
• MV 151 Vs – model with a round flange and a protecting insect screen.
MV 151 VR – model with a round flange and air flow regulator (VR)
• Fitted with a round connecting flange for mounting with Ø 150 mm air duct.
• Equipped with a movable flap for air flow regulation.
• Air pass is regulated with a tilt wand or pull cords.
• Suitable for direct mounting with VENTS VKO 150 fan.
• MV 151 VRs – model with a round flange, air flow regulator and a protecting insect
screen.
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2] Fig. no.
B H L L1 D
Fig. 1 Fig. 2
MV 150 Application
Series • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.
• Used for correct air flow distribution in premises.
• Wall or ceiling mounting.
Design
• Made of quality and durable plastic.
• Multi-element structure. The internal part is fixed to the base with latches for easy cleaning without
dismantling.
• Fixing with screws or lugs depending on grille modification.
Colour modifications
Modifications
• Screw fixing.
• MV 150 s – model with a protecting insect screen and screw fixing.
• MV 150 M – model with fixing lugs.
• MV 150 Ms – model with fixing lugs and a protecting insect screen.
• Screw fixing.
• Equipped with four-element connecting flange with adjustable diameter for connection to Ø
100-150 mm round air duct.
• MV 150 VDs – model with four-element connecting flange, screw fixing and a protecting
insect screen.
• MV 150 VDM – model with four-element connecting flange and fixing lugs.
• MV 150 VDMs – model with four-element connecting flange, fixing lugs and a protecting
insect screen.
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2] Fig. no
B H L L1 D
MV 150 204 179 16 – – 0.0092 1, 2
MV 150 VD 204 179 16 41 100-150 0.0092 1, 3
MV 150-1 Application
Series • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.
• Used for correct air flow distribution in premises.
• Wall or ceiling mounting.
Design
• Made of quality and durable plastic.
• Multi-element structure. The internal part is fixed to the base with latches for easy cleaning without
dismantling.
• Fixing with glue or silicon.
Colour modifications
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2]
B L
MV 150-1 192 8 0.0092
MV 160 Application
Series • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.
• Used for correct air flow distribution in premises.
• Wall or ceiling mounting.
Design
• Made of quality and durable plastic.
• Multi-element structure. The internal part is fixed to the base with latches for easy cleaning without
dismantling.
• Fixing with screws or lugs depending on grille modification.
Colour modifications
Modifications
• Screw fixing.
• MV 160 s – model with a protecting insect screen and screw fixing.
• MV 160 M – model with fixing lugs.
• MV 160 Ms – model with fixing lugs and a protecting insect screen.
• Screw fixing.
• Equipped with four-element connecting flange with adjustable diameter for connection to Ø
100-150 mm round air duct.
• MV 160 VDs – model with four-element connecting flange and a protecting insect screen.
• MV 160 VDM – model with four-element connecting flange and fixing lugs.
• MV 160 VDMs – model with four-element connecting flange, fixing lugs and a protecting
insect screen.
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2] Fig. no.
H B L L1 H1 B1 D
MV 160 299 221 15 – 283 205 – 0.026 1, 2
MV 160 VD 299 221 15 42 283 205 100-150 0.026 1, 3
MV 170 Application
Series • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.
• Used for correct air flow distribution in premises.
• Wall or ceiling mounting.
Design
• Made of quality and durable plastic.
• Multi-element structure. The internal part is fixed to the base with latches for easy cleaning without
dismantling.
• Screw fixing.
Colour modifications
MV 170 VDR – model with four-element connecting flange and air flow regulator
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2] Fig. no.
H B L L1 H1 B1 D
MV 170 221 299 15 – 205 283 – 0.0237 1
MV 170 VD 221 299 15 42 205 283 100-150 0.018 1, 2
MV 170 R 221 299 15 – 205 283 – 0.012 1
MV 170 VDR 221 299 15 42 205 283 100-150 0.088 1, 2 Fig. 1 Fig. 2
MV 250 Application
Series • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.
• Used for correct air flow distribution in premises.
• Wall or ceiling mounting.
Design
• Made of quality and durable plastic.
• Multi-element structure. The internal part is fixed to the base with latches for easy cleaning without
dismantling.
• Fixing with screws or lugs depending on grille modification.
Colour modifications
Modifications
• Screw fixing.
• MV 250 s – model with a protecting insect screen and screw fxing.
• MV 250 M – model with fixing lugs.
• MV 250 Ms – model with fixing lugs and a protecting insect screen.
• OFitted with a round connecting flange for mounting with Ø 200 mm air duct.
• Screw fixing.
• MV 250/200 Vs – model with a round flange and a protecting insect screen.
• Fitted with a round connecting flange for mounting with Ø 150 mm air duct.
• Equipped with a movable flap for air flow regulation.
• Air pass is regulated with a tilt wand or pull cords.
• Suitable for direct mounting with VENTS VKO 150 fan.
• MV 250/150 VRs – model with a round flange, air flow regulator and a protecting insect
screen.
MV 250/200 VR – model with a round Ø 200 mm flange and air flow regulator (VR)
• Fitted with a round connecting flange for mounting with Ø 200 mm air duct.
• Equipped with a movable flap for air flow regulation.
• Air pass is regulated with a tilt wand or pull cords.
• Screw fixing.
• MV 250/200 VRs – model with a round flange, air flow regulator and a protecting insect
screen.
• Equipped with four-element connecting flange with adjustable diameter for connection
to Ø 100-150 mm round air duct.
• Screw fixing.
• MV 250 VDs – model with four-element flange and a protecting insect screen.
MV 250 VDR – model with four-element flange and air flow regulator (VDR)
• Equipped with four-element connecting flange with adjustable diameter for connection
to Ø 100-150 mm round air duct.
• Equipped with a movable flap for air flow regulation.
• Air pass is regulated with a tilt wand or pull cords.
• Screw fixing.
• MV 250 VDRs – model with four-element flange, air flow regulator and a protecting insect
screen.
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2] Fig. no.
H B L L1 D
MV 250 250 214 14 – – 0.02 1, 2
MV 250 R 250 214 14 – – 0.01 1, 2
MV 250/150 V 250 214 14 44 150 0.02 1, 3
MV 250/200 V 250 214 14 44 200 0.02 1, 3
MV 250/150 VR 250 214 14 44 150 0.01 1, 3
MV 250/200 VR 250 214 14 44 200 0.01 1, 3
MV 250 VD 250 214 14 42 100-150 0.02 1, 4
MV 250 VDR 250 214 14 42 100-150 0.01 1, 4
MV 250-1 Application
Series • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.
• Used for correct air flow distribution in premises.
• Wall or ceiling mounting.
Design
• Made of quality and durable plastic.
• Multi-element structure. The internal part is fixed to the base with latches for easy cleaning without
dismantling.
• Fixing with glue or silicon.
• Modifications with a protecting insect screen are available.
Colour modifications
Modifications
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2]
H B L
MV 250-1 230 230 8 0.02
MV 80-1 Application
Series • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.
• Used for correct air flow distribution in premises.
• Wall or ceiling mounting.
Design
• Made of quality and durable plastic.
• Multi-element structure. The internal part is fixed to the base with latches for easy cleaning without
dismantling.
• Fixing with glue or silicon.
• Modifications with a protecting insect screen are available.
Colour modifications
Modifications
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2]
H B L
MV 80-1 80 170 7 0.0039
MV Series Application
single-element • Decoration of supply and exhaust vents of public, residential and
industrial ventilation systems.
• Used for correct air flow distribution in premises.
• Wall or ceiling mounting.
Design
• Made of quality and durable plastic.
• Single-element structure.
• Various fixing modifications depending on the model type: screws, lugs
or glue (silicon).
• Grille modifications with an insect screen.
Colour modifications
Fixation options
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2]
H B L
MV 150x150 150 150 11 0.0058
MV 175x175 175 175 11 0.0089
MV 205x205 205 205 11 0.0135
MV 215x175 215 175 11 0.0115
MV 250x180 250 180 11 0.0141
MV 250x250 250 250 11 0.0213
MV 295x160 295 160 11 0.0147
MV 300x205 300 205 11 0.0207
MV 300x300 300 300 11 0.0302
MV 350x350 350 350 11 0.0432
MV 50 bV MV 51 bV Application
Series Series • Suitable for installation in furniture, bathroom and kitchen door leaves, etc.
• Used to arrange correct air circulation in premises.
Design
• Made of quality and durable plastic.
• Fixed with mounting ribs or glue.
Colour modifications
Modifications
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2] Fig.no.
D D1 D2 L L1
MV 50 bV 59 47 – 3.5 16.5 0.00078 1
MV 51 bV 59 47 – 3 16 0.00078 2
Fig. 1 Fig. 2
MV 52 bV Application
Series • Suitable for installation in furniture, bathroom and kitchen door leaves, etc.
• Used to arrange correct air circulation in premises.
Design
• Made of quality and durable plastic.
• Fixed with mounting ribs or glue.
Colour modifications
Modifications
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2]
D D1 D2 L L1
MV 52 bV 56 40 26 41.5 – 0.00053
MV 80 bV MV 81 bV Application
Series Series • Decoration of supply and exhaust vents of public, residential and
industrial ventilation systems.
• Wall or ceiling mounting.
• Suitable for installation in furniture, bathroom and kitchen door leaves,
etc.
Design
• Made of quality and durable plastic.
• Fixed with mounting ribs or glue.
Colour modifications
Modifications
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2] Fig. no.
D D1 L L1
MV 80 bV 100 80 5 19 0.0035 1
MV 81 bV 100 80 5 19 0.0035 2
Fig. 1 Fig. 2
MV 100 bV Application
MV 125 bV • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.
Colour modifications
Modifications
MV 100 bV, MV 125 bV, MV 150 bV – round grilles with a flange (bV)
• Fitted with a round connecting flange for mounting to Ø 100 mm (MV 100 bV), Ø 125
mm (MV 125 bV) or Ø 150 mm (MV 150 bV) air ducts.
• MV 100 bVs, MV 125 bVs, MV 150 bVs – models with a protecting insect screen.
MV 100 bVR, MV 125 bVR, MV 150 bVR – models with a round flange and air flow regulator (bVR)
• Fitted with a round connecting flange for mounting to Ø 100 mm (MV 100 bVR), Ø 125
mm (MV 125 bVR) or Ø 150 mm (MV 150 bVR) air ducts.
• Equipped with a movable flap for air flow regulation with a slider.
MV 125 bVRD, MV 150 bVRD – models with air flow regulator and four-element connecting flange (bVRD)
• Equipped with four-element connecting flange with adjustable diameter for connection to
Ø 100-125 mm (MV 125 bVRD) and Ø 100-150 mm (MV 150 bVRD) round air ducts.
• Equipped with a movable flap for air flow regulation with a slider.
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2] Fig. no.
L B D1 D
MV 100 bV 29 118 100 128 0.004 1, 2
MV 100 bVR 29 118 100 128 0.005 1, 3
Fig. 1 Fig. 3
MV 125 bV 29 148 125 160 0.0065 1, 2
MV 125 bVR 29 148 125 160 0.005 1, 3
MV 125 bVRD 45 148 100-125 160 0.005 1, 4
MV 150 bV 29 176 150 200 0.01 1, 2
MV 150 bVR 29 176 150 200 0.005 1, 3
MV 150 bVRD 45 176 100-150 200 0.005 1, 4
Fig. 2 Fig. 4
MVVM 162 • T he outer hood is designed to prevent ingress of water and large objects into the ventilation
equipment from outside.
Mounting from inside • re-installed with a hood the air duct is mounted in a core hole drilled in the wall. The installation
P
is done from inside.
• S pecial design allows installation of the hood by the operator on a wall of high-rise buildings and
enables airtight sealing of the air duct in the core hole.
Design
• Made of high-quality incombustible ultraviolet resistant plastic.
• Fixation at the end of the air duct with latches.
• The air duct with diameter of 160 mm is made of high-quality PVC plastic.
• T he ventilation hood [1] is equipped with a silicone sealing ring [2] that provides high sealing
integrity of the air duct [3] in the core hole in the wall.
1 2
Mounting
• Drill a core hole with a diameter of 180 mm in the wall.
• Insert the hood into the wall core hole and push it until the sealing ring appears on the outer side.
• Pull the hood in the opposite direction so the silicone sealing ring provides tight seal between the hood and the wall.
• The air duct must be fixed in the wall core hole using mounting foam.
Overall dimensions
L
Model Air pass, [m2]
mm
184
154
160
MVVM 162 -
MVVM 162 03 300
MVVM 162 05 500 0.0078
MVVM 162 07 700
84 L 207 MVVM 162 08 800
MV 102 Application
MV 122 • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.
Series Design
• Made of quality and durable plastic.
• Two-element structure for easy maintenance.
• Screw fixing.
• Equipped with a protecting grille against birds and rodents.
Colour modifications
Modifications
MV 102 VK, MV 122 VK, MV 152 VK – models with a round flange and a backdraft damper
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2] Fig. no.
B H L L1 L2 Flange (D)
MV 102 / MV 102 K 154 110 15 – 87 – 0.008 1
MV 102 V / MV 102 VK 154 110 15 45 87 100 0.008 1, 2
MV 102 VU / MV 102 VUK 154 110 15 39 87 100, 125, 55*110 0.008 1, 3
MV 122 / MV 122 K 186 142 15 – 101 – 0.012 1
MV 122 V / MV 122 VK 186 142 15 45 101 125 0.012 1, 2
MV 122 VN / MV 122 VNK 186 142 15 115 101 100, 110, 120, 130, 150 0.012 1.4
MV 152 V / MV 152 VK 186 142 15 50 101 150 0.012 1.2
MV 100 J Application
Series • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.
• External wall mounting.
Design
• Made of quality and durable plastic.
• Multi-element structure.
• Fitted with louvre shutters for back flow prevention.
• Screw fixing.
Colour modifications
Modifications
MV 100 VJ – model with a round flange and gravity louvre shutters (VJ)
MV 100 VUJ – model with a multi-section flange and gravity louvre shutters (VUJ)
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2] Fig. no.
B H L L1 Flange (D)
MV 100 J 154 110 15 – – 0.0096 1, 2
MV 100 VJ 154 110 15 45 100 0.0075 1, 3
MV 100 VUJ 154 110 15 39 100, 125, 55x110 0.0096 1, 4
MV 120 J Application
MV 150 VJ • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.
Design
• Made of quality and durable plastic.
• Multi-element structure.
• Fitted with louvre shutters for back flow prevention.
• Screw fixing.
Colour modifications
Modifications
MV 120 VJ, MV 150 VJ – models with a round flange and louvre shutters (VJ)
MV 120 VNJ – model with a flange with various diameters and louvre shutters (VNJ)
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2] Fig. no.
B H L L1 Flange (D)
MV 120 J 186 142 15 – – 0.016 1, 2
MV 120 VJ 186 142 15 45 125 0.0113 1, 3
MV 120 VNJ 186 142 15 115 100, 110, 120, 130, 150 0.012 1, 4
MV 150 VJ 186 142 15 50 150 0.0113 1.3
MV 160 J Application
Series • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.
• External wall mounting.
Design
• Made of quality and durable plastic.
• Multi-element structure.
• Fitted with louvre shutters for back flow prevention.
• Screw fixing.
Colour modifications
Modifications
MV 160 VJD – model with four-element flange and louvre shutters (VJD)
Overall dimensions
MV 250 J Application
Series • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.
• External wall mounting.
Design
• Made of quality and durable plastic.
• Multi-element structure.
• Fitted with louvre shutters for back flow prevention.
• Screw fixing.
Colour modifications
Modifications
MV 250/150 VJ, MV 250/200 VJ – models with a round flange and louvre shutters
• Fitted with a round connecting flange for mounting with Ø 150 mm (MV 250/150 VJ) or Ø
200 mm (MV 250/200 VJ) air ducts.
• Fitted with louvre shutters for back flow prevention.
• Equipped with four-element connecting flange with adjustable diameter for connection to
Ø 100-150 mm round air duct.
• Fitted with louvre shutters.
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2] Fig. no.
B H D L L1
MV 250 J 250 214 – 15 – 0.0177-0.056 1, 2
MV 250 VJD 250 214 100-150 15 41 0.0177-0.056 1, 3
MV 250/150 VJ 250 214 150 15 41 0.0177-0.056 1, 4
MV 250/200 VJ 250 214 200 15 41 0.0177-0.056 1, 5
MV 100 K Application
MV 125 K • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.
Design
• Made of quality and durable plastic.
• Designed for mounting with rigid air ducts.
• Extra ventilation grille is provided to arrange natural ventilation in premises with a gas stove.
• Equipped with deviators for back air flow prevention through the bottom ventilation grille.
• Screw fixing.
• The grille has a removable bottom part for easy cleaning.
Colour modifications
Modifications
• For mounting with rigid Ø 100 mm (MV 100 K) or Ø 125 mm (MV 125 K) air ducts.
• MV 100 Ks, MV 125 Ks – models with a protecting insect screen.
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2]
B H B2 H2 D L L1
MV 100 K 182 252 160 226 100 10 45 0.0039
MV 125 K 182 252 160 226 125 10 45 0.0039
MV 100 KV Application
MV 120 KV • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.
Series Design
• Made of quality and durable plastic.
• Suitable for mounting with flexible air ducts.
• Equipped with deviators for back air flow prevention through the bottom ventilation grille.
• Extra ventilation grille is provided to arrange natural ventilation in premises with a gas stove.
• Screw fixing.
• The grille has a removable bottom part for easy cleaning.
Colour modifications
Modifications
MV 100 KV, MV 120 KV, MV 125 KV – models with a round flange (KV)
• Equipped with a round flange for connection to Ø 100 mm (MV 100 KV), Ø 120 mm
(MV 120 KV), Ø 125 mm (MV 125 KV) air ducts.
• MV 100 KVs, MV 120 KVs, MV 125 Ks – models with a protecting insect screen.
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2]
B H B1 H1 D L1 L
MV 100 KV 182 252 160 226 100 75 10 0.0039
MV 120 KV 182 252 160 226 120 75 10 0.0039
MV 125 KV 182 252 160 226 125 75 10 0.0039
ASA (Acrylonitrile Styrene Acrylate) plastic is a 3-D polystyrene-copolymer with butadiene rubber, an updated version
of ABS plastic.
Due to the specially selected balance of mechanical and physical features the material is the ideal option for external
plastic products. ASA plastic is UV- and weather-resistant, durable and long-lasting.
ASA und ABS polymers have a similar chemical structure. Acrylonitrile and styrene ensure water resistance, elasticity and
hardness. Butadiene rubber adds higher density for ASA plastic and improves its chemical composition. The products made
of ASA plastic have numerous benefits:
high UV-resistance (due to single covalent bonds ASA plastic is less prone to oxidation and UV exposure)
h
igh temperature resistance (thermal deformation temperature is +91 °C)
excellent flexibility and high ultimate resistance (changing of plasticity index does not exceed 2 %)
fire resistance
w
eather resistance (no loss of mechanical properties and deterioration of exterior caused by negative weather impact)
ASA polymers are used in ventilation and car industry (xenon headlamps, car spoilers, radiator grilles, bodies for rear-
view mirror). Owing to high performance features of ASA plastic it is used for manufacture of window profiles, plastic roofs,
external ventilation parts.
Therefore you can shop ASA plastic ventilation grilles by VENTS with entire confidence that they will reliably serve
and retain their visual appeal for years to come. The external grilles are available in white, brown and beige colour
modifications.
Reliability.
ASA High mechanical toughness Long-term retention
UV STABIL and UV-resistance. of basic characteristics.
UV-resistant High light resistant Temperature resistant Морозостойкие Chemical
Ch i l resistant
i t t Reliableresistant
Impact
Contents
page
Exhaust grilles
MV 120 V ASA series 233
page
Design
• Made of quality and durable plastic.
• Multi-element structure. The internal part is fixed to the base with latches for easy cleaning without
dismantling.
• Screw fixing.
• The grille has slanted vanes.
Colour modifications
• Fitted with a round connecting flange for mounting with Ø 100 mm air duct.
• Suitable for direct mounting with VENTS VKO 100 fan.
• MV 100 Vs ASA – model with a round flange and a protecting insect screen.
• Equipped with a multi-section connecting flange for mounting with Ø100, 125 mm
or 55x110 mm air duct.
• MV 100 VUs ASA – model with a multi-section flange and a protecting insect
screen.
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2] Fig. no.
B H L L1 Flange (D)
Design
• Made of quality and durable plastic.
• Multi-element structure. The internal part is fixed to the base with latches for easy cleaning without
dismantling.
• Screw fixing.
• The grille has slanted vanes.
Colour modifications
Modifications
• Fitted with a round connecting flange for mounting with Ø 125 mm air duct.
• Suitable for direct mounting with VENTS VKO 125 fan.
• MV 120 Vs ASA – model with a round flange and a protecting insect screen.
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2] Fig. no.
B H L L1 Flange (D)
Fig. 1 Fig. 2
Design
• Made of quality and durable plastic.
• Multi-element structure. The internal part is fixed to the base with latches for easy cleaning without
dismantling.
• Screw fixing.
• The grille has slanted vanes.
Colour modifications
Modifications
• Fitted with a round connecting flange for mounting with Ø 150 mm air duct.
• Suitable for direct mounting with VENTS VKO 150 fan.
• MV 150 Vs ASA – model with a round flange and a protecting insect screen.
Overall dimensions
Dimensions, [mm]
Model Flange Air pass, [m2] Fig. no.
B H L L1
(D)
Fig. 1 Fig. 2
Design
• Made of quality and durable plastic.
• Multi-element structure. The internal part is fixed to the base with latches for easy cleaning without
dismantling.
• Fixing with screws or lugs depending on grille modification.
Colour modifications
• OFitted with a round connecting flange for mounting with Ø 200 mm air duct.
• Screw fixing.
• MV 250/200 Vs ASA – model with a round flange and a protecting insect screen.
• Equipped with four-element connecting flange with adjustable diameter for connection to Ø
100-150 mm round air duct.
• Screw fixing.
• MV 250 VDs ASA – model with four-element flange and a protecting insect screen.
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2] Fig. no.
B H L L1 Flange (D)
MV 250/150 V ASA 250 214 14 44 150 0.02 1, 2
MV 250/200 V ASA 250 214 14 44 200 0.02 1, 2
MV 250 VD ASA 250 214 14 42 100-150 0.02 1, 3
Colour modifications
Modifications
MV 100 bV ASA, MV 125 bV ASA, MV 150 bV ASA – round grilles with a flange (bV)
• Fitted with a round connecting flange for mounting to Ø 100 mm (MV 100 bV ASA),
Ø 125 mm (MV 125 bV ASA) or Ø 150 mm (MV 150 bV ASA) air ducts.
• MV 100 bVs ASA, MV 125 bVs ASA, MV 150 bVs ASA – models with a protecting insect
screen.
MV 100 bVR ASA – models with a round flange and air flow regulator (bVR)
MV 125 bVRD ASA, MV 150 bVRD ASA – models with air flow regulator and four-element connecting flange (bVRD)
• Equipped with four-element connecting flange with adjustable diameter for connection to
Ø 100-125 mm (MV 125 bVRD ASA) and Ø 100-150 mm (MV 150 bVRD ASA) round air ducts.
• Equipped with a movable flap for air flow regulation with a slider.
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2] Fig. no.
L B D1 D
MV 100 bV ASA 29 118 100 128 0.004 1, 2
MV 100 bVR ASA 29 118 100 128 0.005 1, 3
Fig. 1 Fig. 3
MV 125 bV ASA 29 148 125 160 0.0065 1, 2
MV 125 bVRD ASA 45 148 100-125 160 0.005 1, 4
MV 150 bV ASA 29 176 150 200 0.01 1, 2
MV 150 bVRD ASA 45 176 100-150 200 0.005 1, 4
Fig. 2 Fig. 4
Series Design
• Made of quality and durable plastic.
• Two-element structure for easy maintenance.
• Screw fixing.
• Equipped with a protecting grille against birds and rodents.
Colour modifications
Modifications
MV 102 VK ASA, MV 122 VK ASA, MV 152 VK ASA – models with a round flange and a backdraft damper
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2] Fig. no.
B H L L1 L2 Flange (D)
MV 102 VK ASA 154 110 15 45 87 100 0.008 1, 2
MV 102 VUK ASA 154 110 15 39 87 100, 125, 55*110 0.008 1, 3
MV 122 VK ASA 186 142 15 45 101 125 0.012 1, 2
MV 152 VK ASA 186 142 15 50 101 150 0.012 1.2
Design
• Made of quality and durable plastic.
• Multi-element structure.
• Fitted with louvre shutters for back flow prevention.
• Screw fixing.
Colour modifications
Modifications
MV 100 VJ ASA – model with a round flange and gravity louvre shutters (VJ)
MV 100 VUJ ASA – model with a multi-section flange and gravity louvre shutters (VUJ)
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2] Fig. no.
B H L L1 Flange (D)
MV 100 VJ ASA 154 110 15 45 100 0.0075 1, 2
MV 100 VUJ ASA 154 110 15 39 100, 125, 55x110 0.0096 1, 3
Design
• Made of quality and durable plastic.
• Multi-element structure.
• Fitted with louvre shutters for back flow prevention.
• Screw fixing.
Colour modifications
Modifications
MV 120 VJ ASA, MV 150 VJ ASA – models with a round flange and louvre shutters (VJ)
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2] Fig. no.
B H L L1 Flange (D)
Fig. 1 Fig. 2
Design
• Made of quality and durable plastic.
• Multi-element structure.
• Fitted with louvre shutters for back flow prevention.
• Screw fixing.
Colour modifications
Modifications
MV 250/150 VJ ASA, MV 250/200 VJ ASA – models with a round flange and louvre shutters
MV 250 VJD ASA – model with four-element flange and louvre shutters
• Equipped with four-element connecting flange with adjustable diameter for connection to
Ø 100-150 mm round air duct.
• Fitted with louvre shutters.
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2] Fig. no.
B H D L L1
MV 250 VJD ASA 250 214 100-150 15 41 0.0177-0.056 1, 2
MV 250/150 VJ ASA 250 214 150 15 41 0.0177-0.056 1, 3
MV 250/200 VJ ASA 250 214 200 15 41 0.0177-0.056 1, 4
MV 350 Application
Series • Mounting in door leaves of bathrooms, kitchens, etc.
• Suitable for installation into window sills for correct warm air distribution from radiators.
• Used to arrange correct air circulation in premises.
Design
• Made of high quality plastic.
• Available in various colour modifications.
• Fixing with screws directly to a door leaf or to window sills.
• Modifications with a protecting insect screen or a movable flap for air flow regulation are
available.
Colour modifications
Modifications
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2]
H L
MV 350 130 368 0.014
MV 350 R 130 368 0.0095
MV 350/2 Application
Series • Mounting in door leaves of bathrooms, kitchens, etc.
• Used to arrange correct air circulation in premises.
Design
• The grille consists of two parts.
• Made of high quality plastic.
• Available in various colour modifications.
• Fixing with screws directly to a door leaf.
• Modifications with a protecting insect screen or a movable flap for air flow regulation
are available.
Colour modifications
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2]
H L
MV 350/2 130 368 0.014
MV 350 R/2 130 368 0.0065
MV 450 Application
Series • Mounting in door leaves of bathrooms, kitchens, etc.
• Suitable for installation into window sills for correct warm air distribution from radiators.
• Used to arrange correct air circulation in premises.
Design
• Made of high quality plastic.
• Available in various colour modifications.
• Fixing with screws directly to a door leaf or to window sills .
• Modifications with a protecting insect screen or a movable flap for air flow regulation are
available.
Colour modifications
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2]
H L
MV 450/2 Application
Series • Mounting in door leaves of bathrooms, kitchens, etc.
• Used to arrange correct air circulation in premises.
Design
• The grille consists of two parts.
• Made of high quality plastic.
• Available in various colour modifications.
• Fixing with screws directly to a door leaf.
• Modifications with an insect screen or a movable flap for air flow regulation are
available.
Colour modifications
Modifications
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2]
H L
MV 380 Application
Series • Mounting in door leaves of bathrooms, kitchens, etc.
• Suitable for installation into window sills for correct warm air distribution from radiators.
• Used to arrange correct air circulation in premises.
Design
• Made of high quality plastic.
• Available in various colour modifications.
• Fixing with screws directly to a door leaf or to window sills.
• Modifications with a protecting insect screen or a movable flap for air flow regulation are
available.
Colour modifications
Modifications
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2]
H L
MV 380/2 Application
Series • Mounting in door leaves of bathrooms, kitchens, etc.
• Used to arrange correct air circulation in premises.
Design
• Two-section grille.
• Made of high quality plastic.
• Available in various colour modifications.
• The mating grille parts are connected by slots and fixed with screws.
• Minimum door leaf thickness is 29 mm.
• Required cutout area in door leaf is 86x358 mm.
• Modifications with a protecting insect screen are available.
Colour modifications
Modifications
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2]
H L
MV 430/2 Application
Series • Mounting in door leaves of bathrooms, kitchens, etc.
• Used to arrange correct air circulation in premises.
Design
• The grille consists of two parts.
• Made of high quality plastic.
• Available in various colour modifications.
• The mating grille parts are connected by slots and fixed with screws.
• Required cutout area in door leaf for is 80x434 mm.
• Minimum door leaf thickness is 30 mm.
• Modifications with a protecting insect screen are available.
Colour modifications
Modifications
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2]
H L
MV 440/2 Application
Series • Mounting in door leaves of bathrooms, kitchens, etc.
• Used to arrange correct air circulation in premises.
Design
• The grille consists of two parts.
• Made of high quality white plastic.
• Available in various colour modifications.
• The mating grille parts are connected by slots and fixed with screws.
• Minimum door leaf thickness is 32 mm.
• Required cutout area in door leaf is 99x435 mm.
• Modifications with a protecting insect screen are available.
Colour modifications
Modifications
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2]
H L
A…VR Application
Series • For supply and exhaust ventilation, air conditioning and heating.
• Mounting in false ceilings or walls.
• Used to arrange correct air circulation in premises.
Design
• Made of high quality plastic (ABS plastic or polystyrene).
• Special aerodynamic disk valve design ensures uniform air distribution.
• Smooth air pass regulation due to rotation of central part of the damper.
• Easy mounting with fixing lugs.
• The internal part has a sealing ring for more tight fit.
Grille modifications
A 80 VR, A 100 VR, A 125 VR, A 150 VR, A 200 R – basic modifications
Overall dimensions
Dimensions, [mm]
Model Damper normal Air pass, [m2] Fig. no.
D D1 D2 D3 H max H1 H2
pitch, mm
A 80 VR 80 64 90 132 50 34 16 0...8 0...0.002 1
A 100 VR 100 84 90 148 65 44 26 0...20 0...0.006 1
A 125 VR 125 105 110 166 70 40 20 0...22 0...0.008 1
A 150 VR 150 125 128 200 80 50 30 0...23 0...0.009 1
A 200 R 200 177.6 183 246 80 53 33 0...16 0...0.009 1
A 200 VR 200 177.6 128 246 80 53 33 0...19 0.001...0.008 2
Fig. 1 Fig. 2
The internal part of the air disk valve is pulled out to ensure the required clearance S (mm) (fig. 3) to provide required
air flow according to the diagram.
Fig. 3
A…VRF Application
Series • For supply and exhaust ventilation, air conditioning and heating.
• Mounting in false ceilings or walls.
• Used to arrange correct air circulation in premises.
Design
• Made of high quality plastic (ABS plastic or polystyrene).
• Special aerodynamic disk valve design ensures uniform air distribution.
• Smooth air pass regulation due to rotation of central part of the damper.
• Easy installation with fixing lugs and a mounting flange with a lock ring.
• The internal part has a sealing ring for more tight fit.
Grille modifications
A 80 VRF, A 100 VRF, A 125 VRF, A 150 VRF, A 200 RF – models with a mounting flange
Dimensions, [mm]
Damper normal
Model Air pass, [m2] Fig. no.
D D1 D2 H H1 pitch, mm
Technical parameters
The internal part of the air disk valve is pulled out to ensure the required clearance S mm (fig. 4) to provide required air flow according to the diagram.
A…PR Application
Series • For supply ventilation, air conditioning and heating.
• Designed for wall mounting or installation into false ceiling.
• Used to arrange correct air supply and circulation in premises.
Design
• Made of high quality plastic (ABS plastic or polystyrene).
• Special aerodynamic disk valve design ensures uniform air distribution.
• Smooth air pass regulation due to rotation of central part of the damper.
• Easy mounting with fixing lugs.
• The internal part has a sealing ring for more tight fit.
Grille modifications
The internal part of the air disk valve is pulled out to ensure the required clearance S (mm) to provide required air flow according to the diagram.
Overall dimensions
Dimensions, [mm]
Damper normal
Model Air pass, [m2] Fig. no.
D D1 D2 D3 H max H1 H2 pitch, [mm]
Fig. 1 Fig. 2
A…PRF Application
Series • For supply ventilation, air conditioning and heating.
• Designed for wall mounting or installation into false ceiling.
• Used to arrange correct air supply and circulation in premises.
Design
• Made of high quality plastic (ABS plastic or polystyrene).
• Special aerodynamic disk valve design ensures uniform air distribution.
• Smooth air pass regulation due to rotation of central part of the damper.
• Easy mounting with fixing lugs.
• The internal part has a sealing ring for more tight fit.
Grille modifications
The internal part of the air disk valve is pulled out to ensure the required clearance S (mm) to provide required air flow according to the diagram.
Overall dimensions
Dimensions, [mm]
Damper normal
Model Air pass, [m2] Fig. no.
D D1 D2 H max H1 H2 pitch, [mm]
Fig. 1 Fig. 2
AM…PRF Application
Series • For supply ventilation, air conditioning and heating.
• Designed for wall mounting or installation into false ceiling.
• Used to arrange correct air supply circulation in premises.
Design
• Made of polymer-coated steel.
• Special aerodynamic disk valve design ensures uniform air distribution.
• Smooth air pass regulation due to rotation of central part of the damper.
• Equipped with a mounting flange for easy connection to round Ø 100-200 mm air ducts.
• Mounting flange is fixed to false ceiling with screws.
• The internal part has a sealing ring for more tight fit.
Overall dimensions
Dimensions [mm]
Model
D D1 D2 D3
The internal part of the air disk valve is pulled out to ensure the required clearance S (mm) to provide required air flow according to
the diagram.
AM…VRF Application
Series • For supply and exhaust ventilation, air conditioning and heating.
• Mounting in false ceilings or walls.
• Used to arrange correct air circulation in premises.
Design
• Made of polymer-coated steel.
• Special aerodynamic disk valve design ensures uniform air distribution.
• Smooth air pass regulation due to rotation of central part of the damper.
• Equipped with a mounting flange for easy connection to round Ø 100-200 mm air ducts.
• Mounting flange is fixed to false ceiling with screws.
• The internal part has a sealing ring for more tight fit.
Overall dimensions
Dimensions [mm]
Model
D D1 D2 D3
The internal part of the air disk valve is pulled out to ensure the required clearance S (mm) to provide required air flow according to the
diagram.
AM...VRF N Application
Series • For supply and exhaust ventilation, air conditioning and heating.
• Mounting in false ceilings or walls.
• Used to arrange correct air circulation in premises.
Design
• Made of stainless steel.
• Special aerodynamic shape enables uniform air distribution.
• Smooth air flow control due to the central valve rotation.
• Equipped with a round Ø 100, 125 or 150 mm spigot for connection to air ducts.
• Easy mounting with fixing lugs or screws.
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2]
D D1 L
AM 100 VRF N 97 118 52 0.0032
AM 125 VRF N 120 141 52 0.0057
AM 150 VRF N 145 162 62 0.0090
AM 200 VRF N 195 214 73 0.0132
MV…PF Application
Series • For supply ventilation, air conditioning and heating.
• Designed for wall mounting or installation into false ceiling.
• Used to arrange correct air circulation in premises.
Design
• Made of high quality plastic (ABS plastic or polystyrene).
• Special aerodynamic disk valve design ensures uniform air distribution.
• Easy mounting with a mounting flange and a lock ring.
• The internal part has a sealing ring for more tight fit.
• Models with a built-in insect screen.
Diffuser modifications
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2]
D D1 H H1
FL 100 Application
Series • For supply and exhaust ventilation and air conditioning systems.
• For synchronous ventilation and backlighting of premises.
• Designed for a wall or suspended ceiling mounting.
• T he best solution for use in exhaust systems of premises with high humidity, such as bathrooms and
WCs, due to safe voltage 12 V.
Design
• Made of high quality plastic.
• T he diffuser is supplied with a LED lamp with power demand from 1 to 7 W and light temperature
from 3000 K (white warm) to 7000 K (white cold).
• Special aerodynamic shape ensures uniform air distribution.
• Easy mounting with a mounting flange and screws.
• External removable grille for technical maintenance and cleaning.
• Removable front panels are available in 3 colours: white, chrome and gold.
• IP rating is IPX4.
Colour modifications
Diffuser modifications
A model with a LED lamp 12 V/50 Hz: FL 100 LED 3K (12 V/50 Hz)
A model with a LED lamp 220-240 V/50 Hz: FL 100 LED 3K (220-240 V/50 V)
Overall dimensions
Dimensions [mm]
Model Air pass [m2]
D D1 L L1
FL2-100 Application
Series • For supply and exhaust ventilation and air conditioning systems.
• For synchronous ventilation and backlighting of premises.
• Designed for a wall or suspended ceiling mounting.
• T he best solution for use in exhaust systems of premises with high humidity, such as bathrooms
and WCs.
Design
• Made of high quality plastic.
• T he diffuser is supplied with a LED lamp with power demand from 3 to 7 W and light temperature
from 3000 K (white warm) to 7000 K (white cold).
• Special aerodynamic shape ensures uniform air distribution.
• Easy mounting with a mounting flange and screws.
• External removable grille for technical maintenance and cleaning.
• IP rating is IPX4.
Diffuser modifications
A model with a LED lamp FL2 100 LED 3K (12 V/50 Hz) A model with a LED lamp and a transformer unit FL2-T 100 LED 3K
• A LED lamp (3 W). • A LED lamp (3 W).
• Safe lamp voltage: 12 V/50 Hz. • The delivery set includes a 100-240/12 V power unit for LED lamps.
• White warm lightning colour - 3000 K. • Safe lamp voltage: 12 V.
• Lamp cap: G5.3. • White warm lightning colour - 3000 K.
• Supplied with a terminal box. • Lamp cap: G5.3.
• Supplied with a terminal box.
Dimensions [mm]
Model Air pass [m2]
D D1 L L1
Additional equipment
chrome
FL2-100 chrome
Exhaust gravity
metal grille page
MVM...VJ N Series 295
Exhaust metal
hoods page
MVM Application
Series • Decoration of exhaust vents of public, residential and industrial ventilation systems.
• For supply ventilation and air conditioning.
• Used for correct air flow distribution in premises.
• Internal or external wall and ceiling mounting.
Design
• Made of steel, galvanized steel or aluminium and are suitable for colourful polymer
painting.
• Screw fixing.
• Quality materials and zinc-phosphate treatment ensure coating integrity and provide
reliable corrosion protection.
• Modifications with a protecting insect screen are available.
Modifications
• MVM … – basic steel models with white polymer coating.
• MVM … s – steel models with white polymer coating and a protecting insect screen.
• MVM ... A – aluminium grille models with white polymer coating.
• MVM ... s A – aluminium models with white polymer coating and protecting insect
screen.
• MVM ... A (no/p) – aluminium grille models.
• MVM ... s A (no/p) – aluminium models with a protecting insect screen.
• MVM … Zn – galvanized steel grille models.
• MVM … s Zn – galvanized steel models with a protecting insect screen.
• MVM … «colour code» – colourful polymer painted models.
Colour modifications
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2]
L h A
MVM 125 125 111 0.8 0.0035
MVM 150 150 136 0.8 0.0060
MVM 200 200 182 0.8 0.0117
MVM 250 250 234 0.8 0.0166
MVM 300 300 284 0.8 0.0249
MVMP Application
Series • Decoration of exhaust vents of public, residential and industrial ventilation systems.
• For ventilation, air conditioning and heating.
• Used for correct air flow distribution in premises.
• Internal or external wall and ceiling mounting.
Design
• Made of steel, galvanized steel or aluminium and are suitable for colourful polymer
painting.
• Screw fixing.
• Quality materials and zinc-phosphate treatment ensure coating integrity and
provide reliable corrosion protection.
• Modifications with a protecting insect screen are available.
Modifications
• MVMP … – basic steel models with white polymer coating.
• MVMP …s – steel models with white polymer coating and a protecting insect
screen.
• MVMP ... A – aluminium grille models with white polymer coating.
• MVMP ... s A – aluminium models with white polymer coating and protecting insect
screen.
• MVMP ... A (no/p) – aluminium grille models.
• MVMP ... s A (no/p) – aluminium models with a protecting insect screen.
• MVMP …Zn – galvanized steel grille models.
• MVMP … s Zn – galvanized steel models with a protecting insect screen.
• MVMP … «colour code» – colourful polymer painted models.
Colour modifications
Dimensions, [mm]
Model Air pass, [m2]
L H I h A
MVMP 70 70 70 56 56 0.8 0.0009
MVMP 70x140 70 140 56 126 0.8 0.0018
MVMP 100 100 100 86 86 0.8 0.0018
MVMP 100x200 100 200 86 186 0.8 0.0050
MVMP 100x300 100 300 86 288 0.8 0.0081
MVMP 125 125 125 111 111 0.8 0.0028
MVMP 130x90 130 90 116 76 0.8 0.0019
MVMP 130x170 130 170 116 156 0.8 0.0045
MVMP 140 140 140 126 126 0.8 0.0036
MVMP 150 150 150 136 136 0.8 0.0036
MVMP 150x200 150 200 136 186 0.8 0.0054
MVMP 150x210 150 210 136 196 0.8 0.0054
MVMP 150x215 150 215 136 201 0.8 0.0059
MVMP 150x250 150 250 136 236 0.8 0.0069
MVMP 150x300 150 300 136 286 0.8 0.0081
MVMP 150x350 150 350 136 336 0.8 0.0096
MVMP 155 155 155 141 141 0.8 0.0044
MVMP 170 170 170 156 156 0.8 0.0053
MVMP 175 175 175 161 161 0.8 0.0045
MVMP 175x250 175 250 161 236 0.8 0.0068
MVMP 180x90 180 90 166 76 0.8 0.0030
MVMP 180x250 180 250 166 236 0.8 0.0083
MVMP 190x170 190 170 176 156 0.8 0.0059
MVMP Application
Series • Decoration of exhaust vents of public, residential and industrial ventilation systems.
• For ventilation, air conditioning and heating.
• Used for correct air flow distribution in premises.
• Internal or external wall and ceiling mounting.
Design
• Made of polymer-coated, galvanized steel or aluminium.
• Screw fixing.
• Quality materials and zinc-phosphate treatment ensure coating integrity and provide
reliable corrosion protection.
• Modifications with a protecting insect screen are available.
Modifications
• MVMP … – basic steel models with white polymer coating.
• MVMP … s – steel models with white polymer coating and a protecting insect screen.
• MVMP ... A – aluminium grille models with white polymer coating.
• MVMP ... s A – aluminium models with white polymer coating and protecting insect
screen.
• MVMP ... A (no/p) – aluminium grille models.
• MVMP ... s A (no/p) – aluminium models with a protecting insect screen.
• MVMP … Zn – galvanized steel grille models.
• MVMP … s Zn – galvanized steel models with a protecting insect screen.
• MVMP … «colour code» – colourful polymer painted models.
Colour modifications
Overall dimensions
MVMP Application
Series • Decoration of exhaust vents of public, residential and industrial ventilation systems.
• For ventilation, air conditioning and heating.
• Used for correct air flow distribution in premises.
• Internal or external wall and ceiling mounting.
Design
• Made of steel, galvanized steel or aluminium and are suitable for colourful polymer
painting.
• Screw fixing.
• Quality materials and zinc-phosphate treatment ensure coating integrity and provide
reliable corrosion protection.
• Modifications with a protecting insect screen are available.
Modifications
• MVMP … – basic steel models with white polymer coating.
• MVMP … s – steel models with white polymer coating and a protecting insect screen.
• MVMP ... A – aluminium grille models with white polymer coating.
• MVMP ... s A – aluminium models with white polymer coating and protecting insect
screen.
• MVMP ... A (no/p) – aluminium grille models.
• MVMP ... s A (no/p) – aluminium models with a protecting insect screen.
• MVMP … Zn – galvanized steel grille models.
• MVMP … s Zn – galvanized steel models with a protecting insect screen.
• MVMP … «colour code» – colourful polymer painted models.
Colour modifications
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2] Number of sections
L H I h A
MVMP 305x40/3 305 40 291 26 0.8 0.0022 3
MVMP 305x90/3 305 90 291 76 0.8 0.0050 3
MVMP 305x100/3 305 100 291 86 0.8 0.0056 3
MVMP 370x40/3 370 40 356 26 0.8 0.0027 3
MVMP 400x40/4 400 40 386 26 0.8 0.0029 4
MVMP 475x85/4 475 85 461 71 0.8 0.0074 4
MVMPO Application
Series • Decoration of exhaust vents of public, residential and industrial ventilation systems.
• For ventilation, air conditioning and heating.
• Used for correct air flow distribution in premises.
• Internal or external wall and ceiling mounting.
Design
• Made of steel, galvanized steel or aluminium and are suitable for colourful polymer
painting.
• Edge-raised grille design.
• Screw fixing.
• Quality materials and zinc-phosphate treatment ensure coating integrity and
provide reliable corrosion protection.
• Modifications with a protecting insect screen are available.
Modifications
• MVMPO … – basic steel models with white polymer coating.
• MVMPO … s – steel models with white polymer coating and a protecting insect
screen.
• MVMPO ... A – aluminium grille models with white polymer coating.
• MVMPO ... s A – aluminium models with white polymer coating and protecting
insect screen.
• MVMPO ... A (no/p) – aluminium grille models.
• MVMPO ... s A (no/p) – aluminium models with a protecting insect screen.
• MVMPO …Zn – galvanized steel grille models.
• MVMPO … s Zn – galvanized steel models with a protecting insect screen.
• MVMPO ... «colour code» – colourful polymer painted models.
Colour modifications
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2]
L H I h A
MVMPO 70x140 70 140 56 126 5.5 0.0018
MVMPO 100 100 100 86 86 5.5 0.0018
MVMPO 100x200 100 200 86 186 5.5 0.0050
MVMPO 100x300 100 302 86 288 5.5 0.0086
MVMPO 125 125 125 111 111 5.5 0.0033
MVMPO 130x170 130 170 116 156 5.5 0.0045
MVMPO 130x90 130 90 116 76 5.5 0.0018
MVMPO 140 140 140 126 126 5.5 0.0036
MVMPO 140x180 140 180 126 166 5.5 0.0045
MVMPO 140x240 140 240 126 226 5.5 0.0063
MVMPO 150 150 150 136 136 5.5 0.0036
MVMPO 150x210 150 210 136 196 5.5 0.0054
MVMPO 150x215 150 215 136 201 5.5 0.0059
MVMPO 155 155 155 141 141 5.5 0.0041
MVMPO Application
Series • Decoration of exhaust vents of public, residential and industrial ventilation systems.
• For ventilation, air conditioning and heating.
• Used for correct air flow distribution in premises.
• Internal or external wall and ceiling mounting.
Design
• Made of steel, galvanized steel or aluminium and are suitable for colourful polymer
painting.
• Edge-raised grille design.
• Screw fixing.
• Quality materials and zinc-phosphate treatment ensure coating integrity and provide
reliable corrosion protection.
• Modifications with a protecting insect screen are available.
Modifications
• MVMPO … – basic steel models with white polymer coating.
• MVMPO ... A – aluminium grille models with white polymer coating.
• MVMPO ... s A – aluminium models with white polymer coating and protecting insect
screen.
• MVMPO ... A (no/p) – aluminium grille models.
• MVMPO ... s A (no/p) – aluminium models with a protecting insect screen.
Overall dimensions
MVMPO Application
Series • Decoration of exhaust vents of public, residential and industrial ventilation systems.
• For ventilation, air conditioning and heating.
• Used for correct air flow distribution in premises.
• Internal or external wall and ceiling mounting.
Design
• Made of steel, galvanized steel or aluminium and are suitable for colourful polymer
painting.
• Edge-raised grille design.
• Screw fixing.
• Quality materials and zinc-phosphate treatment ensure coating integrity and provide
reliable corrosion protection.
• Models with insect screen are available.
Modifications
• MVMPO … – basic steel models with white polymer coating.
• MVMPO … s – steel models with white polymer coating and a protecting insect screen.
• MVMPO ... A – aluminium grille models with white polymer coating.
• MVMPO ... s A – aluminium models with white polymer coating and protecting insect
screen.
• MVMPO ... A (no/p) – aluminium grille models.
• MVMPO ... s A (no/p) – aluminium models with a protecting insect screen.
Colour modifications
• MVMPO … Zn – galvanized steel grille models.
• MVMPO … s Zn – galvanized steel models with a protecting insect screen.
• MVMPO … «colour code» – colourful polymer painted models.
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2] Number of sections
L H I h A
MVMPO...R Application
Series • Decoration of exhaust vents of public, residential and industrial ventilation systems.
• For ventilation, air conditioning and heating.
• Used for correct air flow distribution in premises.
• Internal or external wall and ceiling mounting.
Design
• Made of steel or aluminium and are suitable for colourful polymer painting.
• Quality materials and zinc-phosphate treatment ensure coating integrity and
provide reliable corrosion protection.
• Edge-raised grille design.
• Equipped with a movable flap for air flow regulation.
• Screw fixing.
Modifications
• MVMPO … R – basic steel models with white polymer coating.
• MVMPO…R A – aluminium grille models with white polymer coating.
• MVMPO…R A (no/p) – aluminium grille models.
• MVMPO …R «colour code» – colourful polymer painted models.
Colour modifications
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2]
L H I h A
MVMPO 155 R 155 155 132 132 9 0.0047
MVMPO 150x200 R 150 200 132 182 9 0.0067
MVMPO 160 R 160 160 137 137 9 0.0051
MVMPO 200x150 R 200 150 182 132 9 0.0061
MVMPO 200 R 200 200 182 182 9 0.0099
MVMPO 200x250 R 200 250 182 232 9 0.0135
MVMPO 200x300 R 200 300 182 282 9 0.0162
MVMPO 250x200 R 250 200 232 182 9 0.0108
MVMPO 250x300 R 250 300 232 282 9 0.0171
MVMPO 300x200 R 300 200 282 182 9 0.0172
MVMPO 300x250 R 300 250 282 232 9 0.0204
open closed
MVMPO...Rr Application
Series • Decoration of exhaust vents of public, residential and industrial ventilation systems.
• For ventilation, air conditioning and heating.
• Used for correct air flow distribution in premises.
• Internal or external wall and ceiling mounting.
Design
• Made of steel or aluminium and are suitable for colourful polymer painting.
• Quality materials and zinc-phosphate treatment ensure coating integrity and provide
reliable corrosion protection.
• Edge-raised grille design.
Modifications
• MVMPO…R / MVMPO…Rr – basic steel models with white polymer coating.
• MVMPO…R A / MVMPO…Rr A – aluminium grilles with white polymer coating.
• MVMPO...R A (no/p) / MVMPO...Rr A (no/p) is made of Aluminium.
• MVMPO…R «colour code» / MVMPO…Rr «colour code» – colourful grilles with polymer
coating.
Colour modifications
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2]
L H I h A
MVMPO 370x40 Rr 370 40 356 29 9 0.0033
MVMPO 380x40 Rr 380 43 366 29 9 0.0035
MVMPO 495x65 Rr 495 65 477 47 9 0.0072
MVMPO 500x40 Rr 500 40 482 29 9 0.0054
MVMPO 500x90 Rr 500 90 482 72 9 0.0090
MVMPO 650x60 Rr 650 60 632 42 9 0.0063
MVMPO 650x65 Rr 650 65 632 44 9 0.0110
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2]
L H I h A
MVMPO 380x40 R 380 43 366 29 9 0.0035
MVM Application
Series • Mounting in door leaves of bathrooms, kitchens, etc.
• Suitable for installation into window sills for correct warm air distribution from
radiators.
• Used to arrange correct air circulation in premises.
Design
• Made of polymer-coated or galvanized steel and are suitable for painting in various
colours.
• Quality materials and zinc-phosphate treatment ensure coating integrity and
provide reliable corrosion protection.
• Screw or lug fixing.
• Modifications with a protecting insect screen are available.
• Various decorative ornaments.
• Minimum door leaf thickness for grilles with fixing lugs is 30 mm.
Modifications
• MVM… – basic steel models with white polymer coating and screw fixing.
• MVM…s – steel grilles with white polymer coating and a protecting insect screen.
• MVM…K – steel grilles with white polymer coating and fixing lugs.
• MVM…s K – steel models with white polymer coating, fixing lugs and a protecting
insect screen.
• MVM…Zn – galvanized steel models with screw fixing.
• MVM…s Zn – galvanized steel models with screw fixing and a protecting insect
screen.
• MVM…K Zn – galvanized steel models with fixing lugs.
• MVM…s K Zn – galvanized steel models with fixing lugs and a protecting insect
screen.
• MVM… «colour code» – colourful polymer painted models.
Colour modifications
Overall dimensions
MVMP Application
Series • Mounting in door leaves of bathrooms, kitchens, etc.
• Suitable for installation into window sills for correct warm air distribution from radiators.
• Used to arrange correct air circulation in premises.
Design
• Made of polymer-coated or galvanized steel and are suitable for painting in various
colours.
• Quality materials and zinc-phosphate treatment ensure coating integrity and provide
reliable corrosion protection.
• Screw fixing.
• Modifications with an insect screen are available.
• Various decorative ornaments.
• Minimum door leaf thickness for grilles with fixing lugs is 30 mm.
Grille modifications
• MVMP… – basic steel models with white polymer coating and screw fixing.
• MVMP…s – steel grilles with white polymer coating equipped with a protecting insect
screen.
• MVMP…Zn – galvanized steel grilles with screw fixing.
• MVMP…s Zn – galvanized steel grilles with screw fixing and a protecting insect screen.
• MVMP…«colour code» – colourful polymer painted models.
Colour modifications
Overall dimensions
MVMA Application
Series • Mounting in door leaves of bathrooms, kitchens, etc.
• Suitable for installation into window sills for correct warm air distribution from
radiators.
• Used to arrange correct air circulation in premises.
Design
• Made of polymer-coated or galvanized steel and are suitable for painting in various
colours.
• Fixing with lugs.
• Modifications with a protecting insect screen are available.
• Minimum door leaf thickness is 32 mm.
Grille modifications
• MVMA…An – grilles from anodized aluminium
• MVMA…«colour code» – colourful polymer painted models.
• MVMA…s – models from aluminium with a protecting insect screen.
• MVMA…s An – models from anodized aluminium and a protecting insect screen.
Colour modifications
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2]
L H
MVMA 400x60 400 60 0.0062
MVMA 400x80 475 80 0.0093
MVMA 400x100 400 100 0.0120
MVMA 480x80 480 80 0.0120
MVMA 500x60 500 60 0.0078
MVMA 500x80 500 80 0.0120
MVMA 500x100 500 100 0.0156
MVMA 600x60 600 60 0.0093
MVMA 600x80 600 80 0.0140
MVMA 600x100 600 100 0.0186
MVMA 800x60 800 60 0.0120
MVMA 800x80 800 80 0.0186
H1
H
MVM...bV A Application
Series • Decoration of supply and exhaust vents of public, residential and industrial ventilation
systems.
• Applicable for HVAC systems.
• Used for correct air flow distribution in premises.
Design
• Made of aluminium.
• Mounting with fixing lugs.
• Equipped with a round Ø 100 mm spigot for connection to air ducts.
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2]
D L
MVM 101 bV A 101 24 0.0024
Design
• Made of stainless steel.
• Insect screen included.
• Mounting with fixing lugs.
• Equipped with a round Ø 100, 125, 150, 200 mm spigot for connection to air ducts.
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2]
D D1 L
MVM 100 bV N 96 150 134 0.0048
MVM 125 bV N 119 184 165 0.0082
MVM 150 bV N 143 205 190 0.0126
MVM...b N Application
Series • Decoration of supply and exhaust vents of public, residential and industrial
ventilation systems.
• Applicable for HVAC systems.
• Used for correct air flow distribution in premises.
Design
• Made of stamped stainless steel.
• Rubber seals for tight contact to the wall.
• Fixing with screws.
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2]
D D1 L
MVM 100 b N 95 133 22 0.0057
MVM 125 b N 122 165 24 0.0093
MVM 150 b N 144 190 26 0.0138
MVM...bVs N Application
Series • Decoration of supply and exhaust vents of public, residential and industrial
ventilation systems.
Design
• Made of stainless steel.
• Insect screen included.
• Rubber seals for tight contact to the wall.
• Fitted with a round Ø 100, 125, 150, 160 or 200 mm spigot for connection to the air
ducts.
• Fixation to the wall with screws.
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2 ]
D D1 L
MVM 102 bVs N 97 133 52 0.0048
MVM 122 bVs N 120 165 52 0.0082
MVM 152 bVs N 145 192 62 0.0126
MVM 162 bVs N 155 192 62 0.0135
MVM 202 bVs N 195 253 73 0.0178
MVM...bV N Application
Series • Decoration of supply and exhaust vents of public, residential and industrial ventilation
systems.
• Applicable for HVAC systems.
Design
• Made of stainless steel.
• Directing vanes and an insect screen included.
• Rubber seals for tight contact to the wall.
• Equipped with a round Ø 100, 125 or 150 mm
spigot for connection to air ducts.
• Fixing with screws.
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2]
D D1 L
MVM 102 bV N 97 133 52 0.0048
MVM 122 bV N 120 165 52 0.0082
MVM 152 bV N 145 192 62 0.0126
MVM 202 bV N 195 253 62 0.0178
MVM...VJ N Application
Series • Decoration of exhaust vents of public, residential and industrial ventilation systems.
• Applicable for exhaust HVAC systems.
Design
• Made of stainless steel.
• Fixing with screws.
• Rubber seals for tight contact to the wall.
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2]
D H L
MVM 100 VJ N 97 137 x 137 52 0.0070
MVM 125 VJ N 120 167 x 167 52 0.0112
H
MVM 150 VJ N 145 167 x 167 62 0.0164
MVM...V N Application
Series • Decoration of exhaust vents of public, residential and industrial ventilation systems.
Design
• Made of stainless steel.
• Back valve included.
• Rubber seals for tight contact to the wall.
• Equipped with a round Ø 100, 125 or 150 mm spigot for connection to air ducts.
• Fixing with screws.
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2]
D H L
526
MVM 102 V N 97 137 x 137 52 0.0071
H
MVM 122 V N 120 167 x 167 52 0.0113
MVM 152 V N 145 167 x 167 62 0.0165
MVM...bVL A Application
Series • Decoration of supply and exhaust vents of public, residential and industrial
ventilation systems.
• Applicable for HVAC systems.
• Used for correct air flow distribution in premises.
Design
• Made of cast aluminium.
• Equipped with a round Ø 100, 125 or 150 mm spigot for connection to air ducts.
• Insect screen included.
• Rubber seals for tight contact to the wall.
• Fixing with screws.
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2]
D D1 L
MVM 100 bVL A 97 140 52 0.0045
MVM 125 bVL A 120 178 52 0.0067
MVM 150 bVL A 145 178 62 0.0115
MVM...VR N Application
Series • Decoration of supply and exhaust vents of public, residential and industrial ventilation
systems.
• Applicable for HVAC systems.
• Used for correct air flow distribution in premises.
Design
• Made of stainless steel.
• Mounting to rectangular 55x110 and 60x204 mm air ducts with fixing lugs.
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2]
HxB
HxB L
MVM 110*54 VR N 110x54 25 0.0028
MVM 205*61 VR N 205x61 30 0.0042
MVMP...R N Application
Series • Decoration of supply and exhaust vents of public, residential and industrial
ventilation systems.
• Applicable for HVAC systems.
• Used for correct air flow distribution in premises.
Design
• Made of stainless steel.
• Movable flap for air flow control.
• Fixing with screws.
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2]
H1
H
B1 H1 B H
MVMP 260*90 R N 225 75 260 90 0.0036
MVMP 260*165 R N 225 150 260 165 0.0085 B1
MVMP 260*240 R N 225 225 260 240 0.0127 B
MVMP...R A Application
Series • Decoration of supply and exhaust vents of public, residential and industrial
ventilation systems.
• Applicable for HVAC systems.
• Used for correct air flow distribution in premises.
Design
• Made of aluminium.
• Movable flap for air flow control.
• Fixing with screws.
Overall dimensions
Dimensions, [mm]
Model Air pass, [m2]
H1
H
B1 H1 B H
MVMP 260*90 R A 225 75 260 90 0.0036
MVMP 260*165 R A 225 150 260 165 0.0085 B1
MVMP 260*240 R A 225 225 260 240 0.0127 B
MVMO1…b Application
Series • Decoration of exhaust vents of public, residential and industrial ventilation
systems.
• For ventilation, air conditioning and heating.
• Used for correct air flow distribution in premises.
• Internal or external wall and ceiling mounting.
Design
• Made of steel, galvanized steel, stainless steel or aluminium and are suitable for
colourful polymer painting.
• Screw fixing.
• Quality materials and zinc-phosphate treatment ensure coating integrity and
provide reliable corrosion protection.
• Equipped with a protecting insect screen.
Modifications
• MVMO1…bs – basic white polymer coated grilles.
• MVMO1…bs A – aluminium white polymer coated grilles with a protecting insect
screen.
• MVMO1…bs An – grilles made of anodized brushed aluminium with a protecting
insect screen.
• MVMO1…bs Ap – grilles made of polished aluminium with a protecting insect screen.
• MVMO1…bs N – grilles made of stainless steel with a protecting insect screen.
• MVMO1…bs Zn – grilles made of galvanized steel with a protecting insect screen.
• MVMO1…bs "colour code" – colourful polymer painted models.
Colour modifications
Dimensions [mm]
Model Air pass [m2]
D B B1 L
MVMO1 100 bs 142 1.3 8.4 114 0.0051
%
/
%
MVMO…bV Application
Series • Decoration of exhaust vents of public, residential and industrial ventilation
systems.
• For ventilation, air conditioning and heating.
• Used for correct air flow distribution in premises.
• Internal or external wall and ceiling mounting.
Design
• Made of steel, galvanized steel, stainless steel or aluminium and are suitable for colourful
polymer painting.
• Edge-raised grille design.
• Quality materials and zinc-phosphate treatment ensure coating integrity and
provide reliable corrosion protection.
• Modifications with a protecting insect screen.
Colour modifications
Modifications
Overall dimensions
MVMO 100 bV 1, 2
MVMO 100 bV1 99 129 48 0.0051 1, 3
MVMO 100 bV K 1, 4
'
MVMO 125 bV 1, 2
MVMO 125 bV1 124 154.5 48 0.0083 1, 3
MVMO 125 bV K 1, 4
'
'
'
MVMO 150 bV 1, 2
MVMO 150 bV1 149 179.5 48 0.0118 1, 3
MVMO 150 bV K 1, 4
/ / /
MVMO 160 bV 1, 2
MVMO 160 bV1 159 189.5 48 0.0138 1, 3 Fig. 1 Fig. 2
Fig. 3 Fig. 4
MVMO 160 bV K 1, 4
MVMO 200 bV 1, 2
MVMO 200 bV1 198 229 48 0.0214 1, 3
MVMO 200 bV K 1, 4
Polymer coated steel / Galvanized steel Anodized brushed aluminum Polished aluminum / stainless steel
polymer coated aluminium
MVMO…bS K1 Application
Series • Decoration of exhaust vents of public, residential and industrial ventilation systems.
• For ventilation, air conditioning and heating.
• Used for correct air flow distribution in premises.
• Internal/external wall and ceiling mounting.
Design
• Made of steel, galvanized steel, stainless steel or aluminium and are suitable for colourful
polymer painting.
• Equipped with a spacer mechanism for mounting in a round ventilation hole without
additional fastening elements.
• Quality materials and zinc-phosphate treatment ensure coating integrity and provide
reliable corrosion protection.
• Modifications with a protecting insect screen.
Modifications
• Equipped with a plastic spreader gearing to mount in a round air vent.
• MVMO…bs K1 – steel grilles with white polymer coating with a protecting insect screen
and plastic spreader gearing.
• MVMO…bs K1 A – grilles made of white polymer coated aluminium.
• MVMO…bs K1 An – grilles made of anodized brushed aluminium with a protecting
insect screen and plastic spreader gearing.
• MVMO…bs K1 Ap – grilles made of polished aluminium with a protecting insect screen
and plastic spreader gearing.
• MVMO…bs K1 Zn – grilles made of galvanizes steel with a protecting insect screen and
plastic spreader gearing.
• MVMO…bs „colour code“ – colourful polymer painted models.
Overall dimensions
Dimensions D
Model [mm] Air pass [m2]
D L
L
100 MVMO bs K1 129 114 0.0051
125 MVMO bs K1 155 139 0.0083
150 MVMO bs K1 180 164 0.0118
77
160 MVMO bs K1 190 174 0.0133
200 MVMO bs K1 229 211 0.0206
Steel grilles with white Grilles made of white Grilles made of Grilles made of Grilles made of
polymer coating polymer coated anodized brushed polished aluminium galvanizes steel
aluminium aluminium
Flexible air ducts, Polyvent and Isovent series are the air ducts with a frame made The Polyvent and Isovent air ducts’ frame is made of high-carbon steel spiral wire
of spiral wire reinforcement with elastic covering. Semi-flexible air ducts Aluvent with 0.8-2 mm diameter that is covered by a film of various materials.
and Thermovent are the spirally wound air ducts made of durable and less elas- The spiral wire must have corrosion-resistant material and be thoroughly
tic materials. checked to ensure its durability and defeat resistance.
The flexible and semi-flexible air duct design allows easy transportation to The distance between spiral turns is selected to ensure the air duct flexibility,
the site in compressed condition whereas during mounting the air ducts is to preserve its shape, comply with aerodynamic characteristics and to bear the
stretched up to required length. construction load.
The Polyvent series air ducts are available in round and rectangular mo
difications and manifold standard sizes to meet all the mounting require-
ments.
The Aluvent and Thermovent air ducts are the spirally wound air ducts with a
specially designed tight locks that provide impervious seam and complete air
tightness.
The covering materials are selected to suit required applications and differ in
thickness, durability and chemical composition. So the required air duct type is
determined by a specific environment and purpose.
Due to many advantages flexible and semi-flexible air ducts gain more and more
popularity. Environmental protection
Aspiration Aspiration
of chemical of abrasive
Temperature
Series Material vapours and and Application
mode, °C
aggressive powdered
substances particles
660, 661,
Air duct type 615, 6150 606, 6061 600, 601 620, 6201, 621 Aluvent
602, 607
DDT-kerosene X A A A A A
Amyl alcohol A A A A A A
Ammonium hydrate A A A A A A
Acetylene 0 0 0 0 0 A
Acetone A X X X 0 A
Benzene X X X X 0 B
Potassium bicarbonate A A A A A A
Butyl alcohol X A A A A A
Butyl ether 0 A A A A 0
Glycerine A C C C C A
Tannic acid A A A A A A
Potassium carbonate A A A A A X
Sodium carbonate A A A A A A
Xylene X X 0 0 0 A
Hydraulic oil 0 0 0 0 C 0
Methyl alcohol A A A A A A
Formic acid B 0 0 0 C B
Nitrobenzene X X X X 0 A
Ozone X A A A A B
Hydrogen peroxide B A A A A A
Perchloroethylene X 0 0 0 0 B
Sodium chloride A A A A A B
Propane (gas) A A A A A A
Esters (non-flammable) 0 0 0 0 0 0
Hydrochloric acid 15 % A A A A A 0
Spirits 0 C C C B 0
Toluene X X X X 0 A
Trichloroethylene (tri) X 0 0 0 0 C
Carbon monoxide A 0 0 0 0 A
Carbon dioxide A A A A A A
Carbonic acid A A A A A A
Pheron 12 0 B B B B 0
Ammonium phosphate 0 A A A A B
Sodium phosphate A A A A A A
Chlorine dry X 0 0 0 0 B
Potassium chlorate A A A A 0 A
Aluminium chloride A A A A A B
Ammonium chloride A A A A A A
Ferric chloride A 0 0 0 0 X
Zinc chloride A A A A A C
Ethylic alcohol A A A A A 0
Toluene Resistant
Correct air duct connection is of significant importance to ensure reliable oper- • Calculate the air duct length in such a way as to omit any sagging as mount-
ation and aerodynamic characteristics of mounted air ducts. ed.
Flexible air ducts are connected to basic ventilation system components by • Stretch the air duct to its maximum.
various fittings or connected directly to final components as ventilation grilles, • Measure the required length and mark it.
disk valves and fans. • For non-insulated air ducts: cut air duct along a spiral turn with a sharp knife
A wide range of VENTS fittings is designed to consider variety of manifold air or scissors and cut the wire with cutting pliers.
duct connections and facilitate mounting works a lot. • For insulated air ducts: first cut the outer sleeve with scissors. Use gloves
for that.
• Connect the air duct to a fitting by spiral turns, the branch pipe length for
General rules connection to the air duct must be at least 50 mm. Seal the joint with a mount-
ing tape if required.
• Mounted air duct must be stretched to the maximum to avoid pressure loss • Fix it with a fixing clamp.
• Air duct must not be deflected and sagged.
• Keep bend radius as large as possible because the minimum air bend in-
creases pressure drop. To level up this effect the bend radius must be equal to Mounting of non-insulated air ducts
the double air duct diameter.
• Provide grounding during mounting operations as static electricity can be • Cover the branch pipe with the air duct at least by 50 mm by spiral turnings
accumulated during transportation of air containing organic solvents along the over the air duct. Seal the joint with a mounting tape if required.
air ducts. • Fix the air duct with a fixing clamp.
• Air flow in the air duct must have spiral motion.
• Use metal connectors or reducers in case of layout through wall construc-
tions.
• Take precautions not to deform or damage air duct during mounting.
Warning! To avoid deformation stretch Aluvent air ducts gradually from the
middle to the ends.
Cover the branch pipe with the air duct at least by 50 mm by spiral turn-
ings over the air duct.
Pull off the insulation material. Seal the joint with a mounting tape if re-
quired.
Fix the air duct with a fixing clamp.
fig. 1 a fig. 1 b
Pull away the insulation material.
• Fix the outer shell with a mounting tape by wrapping it twice around
the air duct.
fig. 1 c fig. 1 d
• Flexible air ducts are not recommended for use in vertical shafts above
2 floors high.
• In case of application of the flexible air duct in high temperature operat-
ing conditions make sure that the air duct temperature resistance is suitable
for the specific operating conditions.
• During installation in fireproof constructions of the floors/ceilings the air
Suspension points ducts must comply with fire safety requirements.
• Flexible air ducts are not suitable for routing through the floor or below
• Maximum sagging of the air duct between two suspension points must ground. Contact with ground is not allowed.
not exceed 50 mm/m (fig. 1 a). • Use only specially designed air ducts for external mounting.
• Distance between two suspension points ranges between 1.5 to 3 m de- • Air ducts must be mounted far away enough from the places with exces-
pending on the air duct type (fig. 1 b). sive heat generation.
• Effective span distance for the flexible air duct must be 1 meter (fig. 1 b). • Application scope of flexible air ducts can be limited by national norms
• In case of vertical air duct layout the distance between the fixing clamps and standards. Read information on air duct application and technical data
shall be from 1 m to 1.8 m (fig. 1 d). before using the air ducts!
Technical data
Range of sizes [mm] Ø 102; 127; 152; 182; 203; 254; 315 110x54; 60x204
Air duct base Aluminium foil laminated with polyester film
Air duct wire steel spring, 0.8-1.5 mm thick
6051 M0 Safety class incombustible (for M0 model), self-extinguishing (for M1 model)
6051 M1 Operating temperature
-30 ... +250 (for M0 model), -30 ... +150 (for M1 model)
range [°C]
Standard length [m] 10
Available lengths
1; 1.5; 2.5; 3; 6 7.6; 10
(cutting) [m]
Flexible non-insulated aluminium foil Air speed [m/s] 30
air ducts with steel wire frame
Maximum operating
3000
pressure [Pa]
Colour range
Aluminium Brown
(_) (B)
Packing
Order code
605 M0 _ – Aluminium
6051 M1 B – brown
Accessories
Backdraft
Diffusers and air disk valves Grilles and hoods dampers Fittings Clamps
605-Iso M0 605-Sono M0
Item
605-Iso M1 605-Sono M1
Range of sizes [mm] Ø 102; 127; 152; 182; 203; 254; 315
Aluminium foil microperforated aluminium band
Air duct base
laminated with polyester film laminated with polyester film
Air duct wire steel spring, 0.8-1.5 mm thick
Insulation mineral wool, 25 mm
Colour range
Aluminium Brown
(_) (B)
Packing
Cardboard
box
Order code
Iso M0 _ – Aluminium
Sono M1 B – brown
Accessories
Backdraft
Diffusers and air disk valves Grilles and hoods dampers Fittings Clamps
Technical data
Colour range
Aluminium
(_)
Packing
Order code
Polyvent N Ø / length
Accessories
Backdraft
Diffusers and air disk valves Grilles and hoods dampers Fittings Clamps
Technical data
Flexible insulated air ducts
with steel wire frame covered Item Isovent N
with metalized polyester film
Range of sizes [mm] Ø 82; 102; 127; 152; 162; 182; 203; 254; 315; ...630
Air duct base metalized polyester film (45 μm)
Air duct wire steel spring, 0.8-1.5 mm thick
Insulation Mineral wool, 25 mm
Outer sleeve metalized polyester film (45 μm)
Operating temperature
-30...+120
range [°C]
Standard length [m] 7.6
Available lengths
7.6
(cutting) [m]
Air speed [m/s] 30
Maximum operating
3000
pressure [Pa]
Colour range
Aluminium
(_)
Packing
Cardboard
box
Order code
Isovent N Ø / length
Accessories
Backdraft
Diffusers and air disk valves Grilles and hoods dampers Fittings Clamps
660
Technical data
Colour range
White
(_)
Packing
Order code
660
6601
Accessories
Backdraft
Diffusers and air disk valves Grilles and hoods dampers Fittings Clamps
Technical data
Colour range
White
(_)
Packing
Order code
Accessories
Backdraft
Diffusers and air disk valves Grilles and hoods dampers Fittings Clamps
606
Technical data
Colour range
Packing
Order code
606 _ – white
6061 B – brown
G – grey
Accessories
Backdraft
Diffusers and air disk valves Grilles and hoods dampers Fittings Clamps
Technical data
Item 607
Range of sizes [mm] Ø 102; 120 Ø 127; 152; 160; 182; 203; 254
Flexible non-insulated Air duct base PVC film (700 μm)
PVC film air ducts Air duct wire steel spring, 1.5 mm thick
with steel wire frame (700 μm) Operating temperature
-18...+90
range [°C]
Standard length [m] 6 2
Available lengths
6 2
(cutting) [m]
Air speed [m/s] 30
Maximum operating
3000
pressure [Pa]
Colour range
Grey
(_)
Packing
Order code
Accessories
Backdraft
Diffusers and air disk valves Grilles and hoods dampers Fittings Clamps
Technical data
Range of sizes [mm] Ø 102; 114; 121; 127; 133; 140; 152; 165; 182; 203; 228; 254; 279; 304
Flexible non-insulated air ducts with
Air duct base polyester fiber covered with PVC (250 μm)
steel wire frame made of PVC-coated
Air duct wire steel spring, 0.8-2 mm thick
polyester fabric (250 μm)
Operating temperature
-21...+110
range [°C]
Standard length [m] 6
Available lengths
6
(cutting) [m]
Air speed [m/s] 30
Maximum operating
3000
pressure [Pa]
Colour range
Packing
Order code
_ – white
G – grey
B – brown
Accessories
Backdraft
Diffusers and air disk valves Grilles and hoods dampers Fittings Clamps
Technical data
Colour range
Packing
Order code
_ – white
G – grey
B – brown
Accessories
Backdraft
Diffusers and air disk valves Grilles and hoods dampers Fittings Clamps
620
Technical data
Colour range
Transparent
(_)
Packing
Order code
620
6201
Accessories
Backdraft
Diffusers and air disk valves Grilles and hoods dampers Fittings Clamps
Technical data
Flexible polyurethane Range of sizes [mm] Ø 102; 114; 121; 127; 133; 140; 152; 165; 182; 203; 228; 254; 304
non-insulated air ducts Air duct base Specially designed polyurethane film (450 μm)
with steel wire frame (450 μm) Air duct wire spring steel 0.8-2 mm thick
Operating temperature
-21...+110
range [°C]
Standard length [m] 6
Available lengths
6
(cutting) [m]
Air speed [m/s] 30
Maximum operating
3000
pressure [Pa]
Colour range
Transparent
(_)
Packing
Order code
Accessories
Backdraft
Diffusers and air disk valves Grilles and hoods dampers Fittings Clamps
Technical data
Colour range
White
(_)
Packing
Order code
M0
M1
Accessories
Backdraft
Diffusers and air disk valves Grilles and hoods dampers Fittings Clamps
Technical data
615
Item 615 6150
Range of sizes [mm] Ø 102; 127; 152; 182 55x110; 70x150; 80x150; 54x222
Air duct base Polyethylene film ( 150 μm) Polyethylene film (150 μm)
Air duct wire steel spring, 0.8 mm thick
Operating temperature
-18...+70
range [°C]
Standard length [m] 6
Available lengths
6
(cutting) [m]
Air speed [m/s] 30
6150 Maximum operating
3000
pressure [Pa]
Flexible polyurethane
non-insulated air ducts
with steel wire frame
(75 and 150 μm)
Colour range
White
(_)
Packing
Order code
615
6150
Accessories
Backdraft
Diffusers and air disk valves Grilles and hoods dampers Fittings Clamps
Calculation example
• Select a curve that matches the air duct diameter [mm], 200 mm
in this case.
• Find the intersection point of this line with the vertical line of
the required air flow in m3/h, 500 m3/h in this case.
• The horizontal line that shows the pressure loss in Pa per 1 m
straight air duct crosses this intersection point.
• Multiply pressure loss value (2.4 Pa/m at 20°C) by total air duct
length to get the total pressure loss value. To calculate pressure loss
in case of bends consider each bend as extra air duct meter.
Technical data
Packing
Polyethylene Cardboard
Thermal packing
bag box
Order code
M
N
S
D
Accessories
Backdraft
Diffusers and air disk valves Grilles and hoods dampers Fittings Clamps
Technical data
Packing
Cardboard
box
Order code
N _ – by default
S Stainless steel
Zn – galvanized steel
Accessories
Backdraft
Diffusers and air disk valves Grilles and hoods dampers Fittings Clamps
Technical data
Stainless steel air ducts
with high temperature resistance Item Thermovent Aero
80/100/110/120/125/130/135/140/150/160
Diameter range [mm]
/180/200/250/300/350/400
Material Stainless steel
Number of layers 1
Total thickness [μm] 100
Operating temperature
-30…+800
range [°C]
Maximum air speed [m/s] 30
Maximum operating
10 000
pressure [Pa]
Minimum bend radius [mm] 4xD (up to 200 mm diameter) and 4.5D (above 200 mm)
Length [m] 1; 2; 3; 6
Packing
Cardboard
box
Order code
Accessories
Backdraft
Diffusers and air disk valves Grilles and hoods dampers Fittings Clamps
Technical data
Packing
Cardboard
box
Order code
Accessories
Backdraft
Diffusers and air disk valves Grilles and hoods dampers Fittings Clamps
Recommended application
Features
• Applied in residential and industrial ventila-
• Made of incombustible corrosion-resisting tion, air conditioning and heating systems with
stainless steel band. the maximum pressure 10 000 Pa.
• Increased thermal resistance (up to 800°C). • For supply and exhaust ventilation.
• Specially designed high-quality locks ensure • Applied in the systems of hot air removal from
high seam tightness and total air tightness of the boiler houses and smoke exhaust systems.
Technical data
Double-layer stainless steel air ducts
with high temperature resistance Item Thermovent Aero Flex
50/60/80/100/110/120/125/130/135/140
Diameter range [mm]
/150/160/180/200/250/300/350/400
Material Stainless steel
Number of layers 2
Internal
Total 100
layer
thickness
[μm] External
100
layer
Operating temperature
-30…+800
range [°C]
Maximum air speed [m/s] 30
Maximum operating
10 000
pressure [Pa]
up to
Minimum 4D
Ø 200 mm
bend radius
[mm] above Ø 200
4.5xD
mm
Length [m] 1; 2; 3; 6
Packing
Cardboard
box
Order code
Accessories
Backdraft
Diffusers and air disk valves Grilles and hoods dampers Fittings Clamps
Calculation example
• Select a curve that matches the air duct diameter [mm], 200 mm
in this case.
• Find the intersection point of this line with the vertical line of
the required air flow in m3/h, 500 m3/h in this case.
• The horizontal line that shows the pressure loss in Pa per 1 m
straight air duct crosses this intersection point.
• Multiply pressure loss value (2.4 Pa/m at 20°C) by total air duct
length to get the total pressure loss value. To calculate pressure loss
in case of bends consider each bend as extra air duct meter.
Cross Tee
KM Series page
Cross Tee
KM…Zn Series page
T-joint
TM Series page
T-joint
TM…Zn Series page
Y-shaped T-joint
TMY Series page
Y-shaped T-joint
TMY…Zn Series page
Reducer
RM Series page
Reducer
RM…Zn Series page
Flange
FM Series page
Reducer
FMK Series page
Reducer
FMK…Zn Series page
Flange
F Series page
Flange
FK Series page
Reducer
PM series page
Reducer
PM…Zn series page
Mounting kit
NM Isovent Series page
350
Clamps page
352
KM KM…Zn Application
Series Series • For branch connections of the air ducts used in resi-
dential, public and industrial ventilation systems.
• For connection of various air ducts and their integra-
tion into complex ventilation systems.
Design
• Made of special steel with polymeric coating (KM se-
ries) or galvanized steel (KM…Zn series).
• The cross tee is designed for connection of 4 air ducts
of the same diameter at 90° angle.
• The cross tee model KM 125/160 is equipped with
two Ø 125 mm and two Ø 160 mm flanges.
• Ventilation system components are fixed by clamps
or any other fixing devices.
Overall dimensions
Dimensions [mm] B
Model ØD
D1 D2 B 1
KM 80 KM 80 Zn 80 80 170
KM 100 KM 100 Zn 100 100 190
KM 110 KM 110 Zn 110 110 200
KM 120 KM 120 Zn 120 120 210
KM 125 KM 125 Zn 125 125 215
Ø D2
Ø D2
Accessories
Backdraft Mounting
Diffusers and air disk valves Grilles and hoods dampers Clamps Air ducts tapes
TM TM…Zn Application
Series Series • For branch connections of the air ducts used
in residential, public and industrial ventilation sys-
tems.
• For connection of various air ducts and their in-
tegration into complex ventilation systems.
Design
• Made of special steel with polymeric coating
(TM series) or galvanized steel (TM…Zn series).
• The T-joint is designed for connection of 3 air
ducts at 90° angle.
• The TM 125/160 T-joint model is equipped with
two � 125 mm flanges and one � 160 mm flange.
• Ventilation system components are fixed by
clamps or any other fixing devices.
Overall dimensions
Dimensions [mm] B
Model ØD
D1 D2 B 2
TM 80 TM 80 Zn 80 80 170
TM 100 TM 100 Zn 100 100 190
TM 110 TM 110 Zn 110 110 200
TM 120 TM 120 Zn 120 120 210
TM 125 TM 125 Zn 125 125 215
Ø D1
Ø D1
Accessories
Backdraft Mounting
Diffusers and air disk valves Grilles and hoods dampers Clamps Air ducts tapes
Design
• Made of special steel with polymeric coating (TMY
series) or galvanized steel (TMY…Zn series).
• The T-joint is designed for connection of 3 air ducts
with the same diameter at 120° angle.
• Ventilation system components are fixed by clamps
or any other fixing devices.
Overall dimensions
Dimensions [mm]
Model
D B
TMY 80 TMY 80 Zn 80 170
TMY 100 TMY 100 Zn 100 190
TMY 110 TMY 110 Zn 110 200
TMY 120 TMY 120 Zn 120 210
TMY 125 TMY 125 Zn 125 215
TMY 130 TMY 130 Zn 130 220
TMY 140 TMY 140 Zn 140 230
B
Accessories
Backdraft Mounting
Diffusers and air disk valves Grilles and hoods dampers Clamps Air ducts tapes
RM RM…Zn Application
Series Series • For branch connections of the air ducts used
in residential, public and industrial ventilation sys-
tems.
• For connection of various air ducts and their in-
tegration into complex ventilation systems.
• For connection of two various air duct dia
meters.
Design
• Made of special steel with polymeric coating
(RM series) or galvanized steel (RM…Zn series).
• The reducer is designed for connection of two
air ducts with various diameters.
• Ventilation system components are fixed by
clamps or any other fixing devices.
Overall dimensions
Dimensions [mm]
Model L
D D1 L
RM 80/100 RM 80/100 Zn 80 100 115
RM 100/125 RM 100/125 Zn 100 125 125
RM 100/120 RM 100/120 Zn 100 120 125
RM 125/150 RM 125/150 Zn 125 150 125
RM 125/160 RM 125/160 Zn 125 160 144
1
RM 150/160 RM 150/160 Zn 150 160 172
RM 150/200 RM 150/200 Zn 150 200 172
RM 160/200 RM 160/200 Zn 160 200 154
RM 200/250 RM 200/250 Zn 200 250 172
RM 250/315 RM 250/315 Zn 250 315 195
Accessories
Backdraft Mounting
Diffusers and air disk valves Grilles and hoods dampers Clamps Air ducts tapes
FM FM…Zn Application
Series Series • For connection of flexible and plastic air ducts of the
respective diameter.
• For wall or ceiling mounting.
Design
• Made of special steel with polymeric coating (FM se-
ries) or galvanized steel (FM…Zn series).
• Fixing to wall or ceiling with screws.
Overall dimensions
Dimensions [mm]
Model
D D1 L L
FM 80 FM 80 Zn 80 116 62
FM 100 FM 100 Zn 100 136 62
FM 110 FM 110 Zn 110 146 62
FM 120 FM 120 Zn 120 156 62
1
Accessories
Backdraft Mounting
Diffusers and air disk valves Grilles and hoods dampers Clamps Air ducts tapes
Design
• Made of special steel with polymeric coating
(FMK series) or galvanized steel (FMK…Zn series).
• The flanges are equipped with a rectangular
connecting plate.
• Fixing to wall or ceiling with screws.
Overall dimensions
Dimensions [mm] L
Model
H B D L
FMK 80 FMK 80 Zn 130 114 80 50
FMK 100 FMK 100 Zn 150 134 100 50
FMK 110 FMK 110 Zn 158 142 110 50
FMK 120 FMK 120 Zn 162 146 120 50
FMK 125 FMK 125 Zn 170 156 125 50
FMK 130 FMK 130 Zn 180 164 130 50
FMK 140 FMK 140 Zn 190 174 140 50
H
FMK 150 FMK 150 Zn 204 188 150 50
FMK 160 FMK 160 Zn 210 194 160 50
FMK 180 FMK 180 Zn 220 204 180 50
FMK 200 FMK 200 Zn 250 234 220 50 B
FMK 250 FMK 250 Zn 300 284 250 50
FMK 315 FMK 315 Zn 360 344 315 50
Accessories
Backdraft Mounting
Diffusers and air disk valves Grilles and hoods dampers Clamps Air ducts tapes
Design
• Made of high-quality plastic.
• F Series flanges are equipped with a retaining ring for
fixation of flexible air ducts.
• The flange model F 200/150 can be used as a connec-
tor for the air disk valves A 200 VR and A 200 R.
• F 250 and F 315 flanges are equipped with an extra
X-deflector to reinforce the flange.
• FK Series flanges are equipped with a connecting
plate.
• Fixing to wall or ceiling with screws.
F 250 – F 315
Series
L
Overall dimensions
1
Dimensions [mm]
Model
D D1 D2 L
F 80 80 115 120 62
F 100 100 132 139 62
2
F 125 125 157 165 62
F 150 150 179 188 62
F 200 200 232 240 62
F 200/150 150 200 179 85
F 250 250 283 290 62 L
F 315 315 360 356 62
Dimensions [mm]
Model
H B D L
H
Accessories
Backdraft Mounting
Diffusers and air disk valves Grilles and hoods dampers Clamps Air ducts tapes
PM PM…Zn Application
Series Series • For connection of flexible air ducts of the re-
spective diameter.
Design
• Made of special steel with polymeric coating
(PM series) or galvanized steel (PM…Zn series).
• Fixing with clamps.
Overall dimensions
Dimensions [mm]
Model L
D L
PM 80 PM 80 Zn 80 62
PM 100 PM 100 Zn 100 62
PM 110 PM 110 Zn 110 62
PM 120 PM 120 Zn 120 62
PM 125 PM 125 Zn 125 62
PM 130 PM 130 Zn 130 62
PM 140 PM 140 Zn 140 62
PM 150 PM 150 Zn 150 62
PM 160 PM 160 Zn 160 62
PM 180 PM 180 Zn 180 62
PM 200 PM 200 Zn 200 62
PM 250 PM 250 Zn 250 62
PM 315 PM 315 Zn 315 62
Accessories
Backdraft Mounting
Diffusers and air disk valves Grilles and hoods dampers Clamps Air ducts tapes
Design
Overall dimensions
A D1
A-A
17
3,5
44holes
отв.
D2
A 20
Delivery set
NM Isovent mounting kit delivery set includes:
- Flange 2 items
- Self-drilling screws with drill 8 items
- Mounting clamp 2 items
- Packing 1 item
Cover the air handling unit spigots with the flanges from NM Isovent mounting kit and Cover the air handling unit spigots with the inner hoses of the heat-insulated air ducts
fix those with self-drilling screws with drill. and fix those with metal clamps (special accessory).
Tuck the inner insulation layer of the air ducts under the flanges of NM Isovent mount- Cover the flanges of NM Isovent mounting kit with inner hoses of heat-insulated air
ing kit. ducts by pressing the hoses tightly against the air handling unit casing and fixing those
with clamps (included into delivery).
Tighten the connection point between the inner hose of the heat-insulated air ducts Heat-insulated air ducts have reliable connection to the air handling unit spigots.
and the flanges of NM Isovent mounting kit with clamps.
The unit is ready to operate!
CZK CZ C
Series Series series
(nylon)
NZC snips
C CB CBR
Series Series Series
Application release clamps equipped with a stainless steel 1. Bend the edge of the band;
The clamps are designed for quick and reliable swing screw. The clamps are tightened with a 2. Fix the bent end inside the band holder;
mounting and connection of various round ven- screw. 3. Turn the band holder up to the required dia
tilation system components. The clamps facilitate • The CBR 3000 model is a band clamp in plastic meter marking on the casing;
installation process and fan removal for servicing casing (roll 30 m x 9 mm x 0.8 mm + 50 locking de- 4. Cut the band according to the marking on the
and maintenance. vices SU 50). Get the required clamp diameter with casing;
a clamp band of respective length and a locking de- 5. Fix the locking device on the band clamp.
Design vice. The clamps are tightened with a screw.
• C series clamps are made of stainless steel Snip cutters are everything you need to get the re-
band and CZ series clamps are made of galvanized quired clamp diameter as the plastic casing has a
steel band. The clamps are tightened with a screw. special design and necessary marking.
• CB series clamps are the stainless steel quick- Use:
Overall dimensions
Dimensions [mm]
Model
D H
C 100 90-110 9
C 125 110-130 9
C 150 140-160 9 1 2 3 4 5
C 160 150-170 9
C 200 190-210 9
C 250 240-260 9
C 315 300-330 9
Overall dimensions
Dimensions [mm]
Model
D H Locking device SU 50 for CBR 3000
CB 60-110 60-110 9
CB 60-135 60-135 9
CB 60-165 60-165 9
Length [m] 50 10 50 10
Width [mm] 50 50 50 50
Base thickness [μm] 30 30 55 55
Total tape thickness [μm] 32 32 96 96
Breaking force 57 N / 25 mm2 57 N / 25 mm2 336 N / 25 mm2 336 N / 25 mm2
Elongation at break [no more %] 3 3 6 6
Adhesiveness 8.25 N / 25 mm 2
8.25 N / 25 mm 2
10 N / 25 mm 2
10 N / 25 mm2
Operating temperature [°C] +10 ... +40 +10 ... +40 +10 ... +40 +10 ... +40
Max. working area surface [°C] +100 +100 +100 +100
UV-resistance yes yes yes yes
"Plastivent" air ductwork system is the ideal solution for arrangement of ventilation systems in small and medium-sized
residential, office and commercial premises as well for connection of cooker hoods, exhaust hoods, cowls and other exhaust
equipment. It includes rectangular 55x110, 60x120, 60x204 mm air ducts, round Ø 100, 125, 150, 200 mm air ducts and a great
variety of fittings such as bends, reducers, connectors, etc. Operation temperature from -30 0C up to +70 0C.
90° bend for round ducts 45° bend for round ducts T-joint for round ducts
Round to flat connector Round flexible duct Holder for round ducts
connector
Flexible flat duct Air duct connector with Air duct connector with
connector a plate a plate and a back valve
Vertical 90° bend for Horizontal 90° bend for Versatile flat angular
flat ducts flat ducts connector
T-joint for flat ducts Flat duct holder 90° connecting bend for
flat and round ducts
T-joint for flat and Reducer for flat ducts Wall plate for flat ducts
round ducts
End grille End grille with air pass Reducer for flat and
regulation round ducts
page page
384 385
Kitchen
Bathroom
Apartment
MV 120 VJ
Aluvent Ø125
Cafe Vents ВК 125
Aluvent Ø125
С 125
A 125 VRF
A 125 VRF
A 125 VRF
A 125 VRF
Aluvent Ø 150
A 125 VRF
Aluvent Ø 100
C 125
C 125
Aluvent Ø 125
C 125
A 125 VR A 125 VR
A 125 VR
A 125 VR
Office
Aluvent Ø125
Aluvent Ø125
Vents VK 150
FB 150
MVM 300
Vents 150 VK
Aluvent Ø125
C 125
C 125
A 125 VRF
A 125 VRF
Aluvent Ø125
C 125
A 125 VRF
Design D1
30 30
Pressure loss [Pa]
25 25
1010/2 (ø100 mm)
1010 (ø100 mm)
2010 (ø125 mm)
20 20
15 15
3010 (ø150 mm)
2010/2 (ø125 mm)
10 10
0 0
0 100 200 300 400 500 600 700 800 0 100 200 300 400 500 600
Air flow [m3/h] Air flow [m3/h]
30
25
20
15
10
366 5
VENTS. Domestic ventilation. Catalogue №6 | 02-2020
Round telescopic duct Application Design
• Supply and exhaust ventilation of various • Made of white PVC.
premises.
• Telescopic design of two parts.
• Wall mounting.
• Diameters: 100, 125, 150 mm.
• Air duct length is adjusted within 300 to 500
or 500 to 1000 mm.
Dimensions [mm]
Code D1 D3
D D1 D2 D3 L
1805 100 103 104 107 300-500
2805 125 128 129 132 300-500
3805 150 153 154 157 300-500
D L D2
1810 100 103 104 107 500-1000
2810 125 128 129 132 500-1000
inner duct outer duct
3810 150 153 154 157 500-1000
Dimensions [mm] D1
Code
a D D1
1113 60 100 103
2123 60 125 128
3133 60 150 153
4143 60 200 204 a D
Dimensions [mm]
Code
D D1 a b
a
60
222 (ø125 mm)
50
40
121 (ø100 mm)
30
20
0
0 100 200 300 400 500 600 700 800
Air flow [m3/h]
16
121-45 (ø100 mm)
с
14
12
10
b
a
D1
8
D
6
4
222-45 (ø125 mm)
2
0
0 50 100 150 200 250 300 350
Air flow [m3/h]
T-joint Application
for round ducts • Formation of branch connections in supply or exhaust ventilation systems located in residential,
public and other buildings.
• Connection of same diameter round ducts and integration into complex ventilation systems.
Design
• Made of white plastic.
• Connection of same diameter three round ducts at 90°.
• Connecting diameters: 100, 125, 150 mm.
D
Dimensions [mm] D1
Code b
D D1 a b c
131 100 97 173 30 139
c
Design
• Made of white plastic.
• Screw fixing to wall.
• Connecting diameters: 100, 125, 150, 200 mm.
Dimensions [mm]
Code
D h a b
b
Design
• Made of white plastic.
• Designed for direct installation into air duct and equipped with a lock ring.
• Connecting diameters: 100, 125, 150, 200 mm.
Dimensions [mm] D
Code
D D1 a
111 100 96 62
212 125 123 62
313 150 148 62
414 200 197 62 a D1
Connector Application
with backdraft damper • Supply and exhaust ventilation of various premises.
Design
• Made of white plastic.
• Equipped with a backdraft damper for back flow prevention.
• Designed for direct installation into air duct and equipped with a lock ring.
• Connecting diameters: 100, 125, 150, 200 mm.
Dimensions [mm] D
Code
D D1 a
1111 100 96 62
2121 125 123 62
3131 150 148 62
4141 200 197 62 a D1
120
Pressure loss [Pa]
2121 (125)
100
80
60
3131 (150)
4141 (200)
40
1111 (100)
20
0
0 200 400 600 800 1000 1200 1400
Air flow [m3/h]
Design
• Made of white plastic.
• Equipped with a wall plate for decoration of mounting openings.
• Equipped with a backdraft damper for back flow prevention.
• Screw fixing to wall.
• Connecting diameters: 100, 125, 150, 200 mm.
D
Dimensions [mm]
Code
a b c D
1511 150 134 62 100
b
2521 170 154 62 125
3531 204 188 62 150
4541 250 230 62 200
a c
Design
• Made of white plastic.
• Equipped with a wall plate for decoration of mounting openings.
• Screw fixing to wall.
• Connecting diameters: 100, 125, 150, 200 mm.
D
Dimensions [mm]
Code
a b c D
b
Design
• Made of white plastic.
• Connecting diameters: 80-100, 100-120, 100-125, 100-150, 125-150, 150-200 mm.
Dimensions [mm]
Code
a D1 D2 D3 D4
110 60 103 100 76 80
D1
D3
D4
D2
211 60 129 125 96 100
311 96 154 150 98.5 100
312 60 154 150 121 125
413 71 204 200 146 150 a
611 60 124 120 98.5 99
60 60 140 140
Pressure loss [Pa]
100 100
40 40 211 (Convergent)
110 (Convergent) 80 80
30 30
60 60
20 20
40 40
110 (Divergent) 211 (Divergent)
10 10
20 20
0 0 0 0
0 50 0 10050 150100 200150 250200 300250 350300 350 0 0 200 200400 400600 600800 800
Air flow [m3/h] Air flow [m3/h]
160 70 160 70
120
50
140 140
60 60
100
120 120 40
50 50
311 (Convergent)
100 80 100
40 30 40
80 60 80 312 (Convergent)
30 30
60 60 20
40
20 20
40 40 312 (Divergent)
10
20
20 10 20 10
311 (Divergent)
0 0 0 0 0 0
0 100 0 200 300 200400 500 400600 700 600
800 800 0 100 0 100
200 200
300 300
400 400
500 500
600 600700 700 800 0 0 200 100 200
400 300 400
600 500 800600 700
Air flow [m3/h] Air flow [m3/h]
40 60 180 30 80 30
Pressure loss [Pa]
160 70
20
50 25 25
140
60
00
611 (Convergent)
40 120 20 20
50
80 100 413 (Convergent)
30 15 40 15
60 80
30
20 60 10 10
40
20
40
10 5 5 611 (Divergent)
20
20 413 (Divergent) 10
0 0 0 0 0 0
0 0 200 200400 400600 600800 800 0 100 0 200 300 200
400 500 400
600 700 600
800 800 0 100 200
0 300
100 400
200 500
300 600
400 700
500 600 7
Air flow [m /h] 3
Air flow [m3/h]
Reducer Application
• Supply and exhaust ventilation of various premises.
• Connection of Ø 120 and 125 mm round air ducts.
Design
• Made of white plastic.
• Connecting diameters: 125-129 mm.
Dimensions [mm]
Code
D1
D2
D3
D4
a D1 D2 D3 D4
216 42 129 125 115 119
30 30
Pressure loss [Pa]
25 25 a
20 20
15 15
216 (Convergent)
10 10
216 (Divergent)
5 5
0 0
0 200 400 600 800 0 100 200 300 400 500 600 700
Air flow [m3/h]
125
120
Dimensions [mm]
Code
a Ø
310 125 80-100-120-125-150
180 80
Pressure loss [Pa]
100
150-80
150-80
150-100 40
150-100
80
150-120
150-120
150-125
30
150-125
60
20
40
20 10
0 0
0 100 200 300 400 500 600 700 800 0 100 200 300 400 500 600 700 800
Air flow [m3/h] Air flow [m3/h]
a
Eccentric Application
reducer • Supply and exhaust ventilation of various premises.
D1 D1
D5 D5
D4 D4
D2 D2
D3 D3
• Connection of round ducts.
Design
• Made of white plastic. 2118
a
• Connecting diameters: 100, 120, 125, 130, 150 mm.
a
Dimensions [mm]
Code
D1 D1
D6
D4
D3
D2 D2
D5
a D1 D2 D3 D4 D5 D6
D6
D4
D3
D5
2118 90 125 120 123 103 99 -
3128 96 151 148 152 132 129 125
3128
140 60
Pressure loss [Pa]
100
40
2118 (Convergent)
80
3128 (Convergent)
30
60
20
40
0 0
0 200 400 600 800 0 200 400 600 800
Air flow [m3/h] Air flow [m3/h]
Design
• Made of white plastic.
• Direct connection to round and flat ducts. L
Dimensions [mm]
Code
a a1 b b1 D1 D2 L
511 113 110 59 55 103 100 137
a
711 124 122 64 60 103 100 137
a1
812 208 204 64 60 128 125 140
913 224 220 94 90 150 146 165
b1
b
30 25
Pressure loss [Pa]
812
511 (60x204/125)
(55x110/100) Convergent
25
Convergent 20
511
(55x110/100) 812
711 913 (60x204/125)
20 Divergent
(60x122/100) (90x220/150) Divergent
Convergent Convergent 15
15 711
(60x122/100)
10 Divergent
10
5 913
5 (90x220/150)
Divergent
0 0
0 100 200 300 400 500 600 700 800 0 100 200 300 400 500 600 700 800
Air flow [m3/h] Air flow [m3/h]
Design
• Made of white plastic.
• Connection to flexible air ducts without clamps.
• Flexible spiral seam duct is connected to one side and the other side is connected to Ø 100 mm
flange.
• Left or right (R) thread. Right thread connectors are used with Polyvents air ducts.
Dimensions [mm]
Code
A B C D E
(inner)
E
A
D
1214 90 30 60 100 110
1214R 90 30 60 100 110
B
C
Design
• Made of white plastic.
• Connection to flexible air ducts without clamps.
• Flexible spiral seam duct is connected to one side and the other side is connected to Ø 100 mm
air duct.
• Left or right (R) thread. Right thread connectors are used with Polyvents air ducts.
Dimensions [mm]
Code
(outer)
A B C D E
E
A
D
Holder Application
for round ducts • Supply and exhaust ventilation of various premises.
• Mounting of round ducts to wall, ceiling or any other plane surface.
Design
• Made of white plastic.
• Fixation to plane surface with screws.
• Special snaps provide reliable fixation of the duct with the holder.
• Connecting diameters: 100, 125, 150, 200 mm.
b
Dimensions [mm]
Code
a b D
16 113 20 103
D
26 138 20 128
a
36 163 20 153
46 213 20 203
Design
• Made of white PVC.
• Size: 55x110, 60x122, 60x204, 90x220 mm.
• Duct length from 350 to 2500 mm.
• Connected with matching connectors.
b
b1
a1
a
L
Dimensions [mm]
Code
a b a1 b1 L
50035 55 110 52 107 350
70035 60 122 57 119 350
80035 60 204 57 200 350
90035 90 220 86 216 350
5005 55 110 52 107 500
7005 60 122 57 119 500
8005 60 204 57 200 500
5010 55 110 52 107 1000
7010 60 122 57 119 1000
8010 60 204 57 200 1000
9010 90 220 86 216 1000
5015 55 110 52 107 1500
7015 60 122 57 119 1500
8015 60 204 57 200 1500
9015 90 220 86 216 1500
5020 55 110 52 107 2000
7020 60 122 57 119 2000
8020 60 204 57 200 2000
9020 90 220 86 216 2000
5025 55 110 52 107 2500
7025 60 122 57 119 2500
8025 60 204 57 200 2500
9025 90 220 86 216 2500
70
Pressure loss [Pa]
60
5010 (55x110)
50
40
7010 (60x122)
30
8010 (60x204)
20
9010 (90x220)
10
0
0 200 400 600 800 1000
Air flow [m3/h]
Design
• Made of white plastic.
• Designed for installation into air duct and equipped with a lock ring for easy jointing.
• Connecting sizes: 55x110, 60x122, 60x204, 90x220 mm.
b1
Dimensions [mm]
Code c
a b a1 b1 c b
515 56 110 59 114 66
a1
717 60 122 65 126 69
a
818 60 204 65 209 62
919 90 220 95 225 62
Design
• Made of white plastic.
• Designed for installation into air duct and equipped with a lock ring for easy jointing.
• Equipped with a backdraft damper for back flow prevention.
• Connecting sizes: 55x110, 60x122, 60x204, 90x220 mm.
b1
Dimensions [mm]
Code c
a b a1 b1 c b
5151 56 110 59 114 66
a1
7171 60 122 65 126 69 a
8181 60 204 65 209 62
9191 90 220 95 225 62
30
Pressure loss [Pa]
25
5151 (55x110)
20
8181 (60x204)
15 7171 (60x122)
10
9191 (90x220)
0
0 100 200 300 400 500
Air flow [m3/h]
Design
• Made of white PVC.
• Cover the connector with air duct and fix it with clamps.
• Connecting sizes: 55x100, 60x122, 60x204 mm.
b
Dimensions [mm]
Code b1 c
a b a1 b1 c
5153 55 110 52 107 60
a1
a
7173 60 122 57 119 60
8183 60 204 57 200 60
Design
• Made of white plastic.
• Air ducts are fitted inside the connector.
• Equipped with lock rings for easy adjustment.
• Screw fixing to wall.
• Connecting sizes: 55x110, 60x120, 60x204 mm.
Dimensions [mm]
Code
a b c A B C D L
555 110 55 2 141 154 154 141 131
757 120 60 2 141 154 154 141 131
858 204 60 3 229 154 242 141 186
Design
• Made of white plastic.
• Air ducts are fitted inside the connector.
• Equipped with lock rings for easy adjustment.
• Equipped with a back valve to prevent back drafting.
• Screw fixing to wall.
• Connecting sizes: 55x110, 60x122, 60x204 mm.
Dimensions [mm]
Code
a b c A B C D L
5551 110 55 2 141 154 154 141 131
7571 120 60 2 141 154 154 141 131
8581 204 60 3 229 154 242 141 186
30
Pressure loss [Pa]
25
5551 (55x110)
20
8581 (60x204)
15 7571 (60x122)
10
0
0 100 200 300 400 500
Air flow [m3/h]
Design
• Made of white plastic.
• Connecting sizes: 55x110, 60x122, 60x204, 90x220 mm.
Dimensions [mm] b
Code
a b c a
5252 55x110 89 32
c
7272 60x122 93 32
8282 60x204 103 32
b
16
Pressure loss [Pa]
14
c
5252 (55x110)
12
9292 (90x220)
10
7272 (60x122)
8282 (60x204)
8
0
0 100 200 300 400 500
Air flow [m3/h]
Design
• Made of white plastic.
• Connecting sizes: 55x110, 60x122, 60x204, 90x220 mm.
Dimensions [mm] c
Code
a b c
5251 55x110 143 32
7271 60x122 155 32
a
b
8281 60x204 238 32
c
9291 90x220 262 35
16
Pressure loss [Pa]
a
14
b
5251 (55x110)
12
7271 (60x122)
10
9291 (90x220)
8281 (60x204)
8
0
0 100 200 300 400 500
Air flow [m3/h]
Design
• Made of white plastic.
• Turning point angle from 3° to 48°.
• Depending on selected turning angle one connector side is cut out. Connection to the flat duct
through matching sized connector.
• On flange side direct connection to flat duct of respective size.
• Connecting section: 55x100 and 60x204 mm.
a
Dimensions [mm]
Code 32
a b c
52510 190 143 55x110
82810 286 247 60x204
10
c
Pressure loss [Pa]
8
52510 (55x110)
c
3
82810 (60x204)
2
0
0 50 100 150 200 250 300 350
Air flow [m3/h]
Data for 45° angle
T-joint Application
for flat ducts • Formation of branch connections in supply or exhaust ventilation systems located in residential,
public and other buildings.
• Connection of same sized flat ducts and integration into complex ventilation systems.
Design
• Made of white plastic.
• Connection of same sized three flat ducts at 90°.
• Connecting sizes: 55x110, 60x122, 60x204, 90x220 mm.
• Direct connection to matching sized ducts.
Dimensions [mm]
Code
a b c
c
535 144 174 55x110
a
737 155 185 60x122
838 248 288 60x204
939 261 296 90x220
c
b
Design
• Made of white plastic.
• Fixation to plane surface with screws.
• Specially designed configuration provides reliable duct to holder fixation and quick dismantling.
• Connecting sizes: 55x110, 60x122, 60x204, 90x220 mm.
c
Dimensions [mm]
Code
a b c
b
56 114 59 74
76 126 64 86
86 209 65 169 a
96 227 95 175
Design
• Made of white plastic.
• Connecting dimensions: 55x110-100, 60x122-100, 60x204-100, 60x204-125, 60x204-150, 90x220-125,
90x220-150 mm.
• Flat ducts have direct connection and round ducts are connected through a matching connector.
Dimensions [mm] D1
Code
a D D1 b h L D
521 55x110 100 103 58x113 87 138
721 60x122 100 103 63x125 87 140
h
821 60x204 97 100 64x208 92 220
b
a
822 60x204 122 125 64x208 92 220
L
823 60x204 147 150 64x208 92 220
922 90x220 122 125 94x226 120 230
923 90x220 147 150 94x226 120 230
70
Pressure loss [Pa]
821(60x204/100), 521 (55x110/100),
60
721(60x122/100), 822 (60x204/125),
823 (60x204/150),
923 (90x220/150),
50
922 (90x220/125)
40
30
20
10
0
0 100 200 300 400 500 600 700 800
Air flow [m3/h]
T-joint Application
for flat and round ducts • Formation of branch connections in supply or exhaust ventilation systems located in residential,
public and other buildings.
• Connection of flat and round ducts.
Design
• Made of white plastic.
• Connecting dimensions: 55x110-100 mm. D1
• Direct connection to air duct. D
Dimensions [mm] L
Code
axb D D1 c d h L
531 55x110 100 103 58 113 87 172 d
b
h
a
c
Dimensions [mm]
Code
c
b a c
518 60x204 55x110 30
c
a
Design
• Made of white plastic.
• Screw fixing to wall. a
• Connecting sizes: 55x110, 60x122, 60x204 mm.
Dimensions [mm]
Code
b
E
e
a b c d e D E
55 111 56 2 141 141 154 154
75 123 61 2 141 141 154 154
d c
85 205 61 3 229 141 242 154
D
Design
• Made of white plastic.
• Detachable front part facilitates cleaning.
• Modification with an insect screen (s) is available.
• Connecting dimensions: 55x110 and 60x204 mm.
f
Dimensions [mm]
Code
a b c d e f
d
a
120
571 (55x110)
100
80
60
40
871 (60x204)
20
0
0 50 100 150 200 250 300 350
Air flow [m3/h]
Design
• Made of white plastic.
• Equipped with a movable flap for air flow regulation.
• Air pass is regulated with a tilt wand.
• Detachable front part facilitates cleaning.
• Modification with an insect screen (s) is available.
• Matches with 55x110 and 60x204 mm air ducts.
f
Dimensions [mm]
Code
a b c d e f
d
572 88 137 114 59 73 18
872 93 232 208 64 76 18 b e
c
350
Pressure loss [Pa]
300
572 (55x110)
250
200
150
100
872 (60x204)
50
0
0 50 100 150 200
Air flow [m3/h]
Design
• Made of white plastic.
• Connecting dimensions: 55x110-100 mm.
• Direct connection of reducer to round and flat ducts.
b
Dimensions [mm]
Code
cxb ØD f a
115 58x114 103 62 32
D
c
35
Pressure loss [Pa]
30 a
f
25
115
20 (55x110/100)
Convergent
15
115
10 (55x110/100)
Divergent
0
0 50 100 150 200 250 300 350
Air flow [m3/h]
Design
• Made of white plastic.
• Connecting dimensions: 55x110-100 mm.
• Reducer has direct connection to flat air ducts and connection through connector to round ducts.
Dimensions [mm]
Code
cxb ØD f a
D
c
1156 58x114 100 62 32
35
Pressure loss [Pa]
a
30
f
25
1156
20 (55x110/100)
Convergent
15
1156
10 (55x110/100)
Divergent
0
0 50 100 150 200 250 300 350
Air flow [m3/h]
Design
• Made of white plastic.
• Screw fixing to wall.
• Connecting sizes: 60x122 mm.
Dimensions [mm]
Code
a b c d D e E
750 126 172 3 65 113 60 65
Design
• Made of white plastic. a D1
b D
• Direct connection flat duct, connection to
round duct with connector.
•
h
e
Connecting ducts: 100-60x122 mm.
Dimensions [mm]
Code c c
a b c ØD Ø D1 e h L
7112 124 122 30 100 103 60 64 137
160
Pressure loss [Pa]
140
L
120
7112
100 (60x122/125)
Convergent
80
60
40
7112
20 (60x122/125)
Divergent
0
0 100 200 300 400 500 600 700 800
Air flow [m3/h]
Introducing folding plastic ducts – an innovative and versatile solution for ventilation systems from VENTS. The folding duct
construction benefits logistics and results in significant space savings immediately apparent while storing and handling the
products.
Y :20
QT
0
Y: 2
QT
-20 %
-40 %
-60 %
Construction
• White PVC plastic
• Diameter: 100
• Duct length ranges from 350 to 2.500 mm
• Joined by means of appropriate diameter connectors
Dimensions [mm]
Code
D D1 L
10035-1 100 103 350
1005-1 100 103 500
1010-1 100 103 1000
1015-1 100 103 1500
1020-1 100 103 2000
1025-1 100 103 2500
D1
L
D
Construction
• White PVC plastic
• Cross-section: 55x110
• Duct length ranges from 350 to 2.500 mm
• Joined by means of appropriate section connectors
Dimensions [mm]
Code
a b a1 b1 L
50035-1 55 110 52 107 350
5005-1 55 110 52 107 500
5010-1 55 110 52 107 1000
5015-1 55 110 52 107 1500
5020-1 55 110 52 107 2000
5025-1 55 110 52 107 2500
b
b1
a1
a
Access doors
Access doors page page
DMZ series
DM series
Metal
393 Metal 394
(with lock)
Sample installations
D2 series
Dimensions
Dimensions [mm]
Model
H B H1 B1 H2 L1 L B2
D 100x100 137 137 93 93 98 5 25 98
D 150x150 167 167 123 123 147 5 25 147
D 150x200 217 167 173 123 197 5 25 147
D 150x300 317 167 273 123 297 5 25 147
D 200x200 217 217 173 173 197 5 25 197
D 200x250 267 217 223 173 247 5 25 197
D 200x300 317 217 273 173 297 5 25 197
D 200x400 417 217 373 173 397 5 25 197 D2 series
D 250x250 267 267 246 246 247 5 25 247
D 250x300 347 267 303 223 327 5 25 247
D 250x400 417 267 373 223 397 5 25 247
D 300x300 317 317 273 273 297 5 25 297
D 300x400 417 317 373 273 397 5 25 297
D 300x500 517 317 473 273 497 5 25 297
D 300x600 617 317 573 273 597 5 25 297
D 400x500 517 417 473 373 497 5 25 397
D 400x600 617 417 573 373 597 5 25 397
D2 300x300 317 288 273 244 297 5 25 268
D2 400x400 416 388 372 344 397 5 25 370
Color options
White Beige Grey Sky Blue Beige Marble Grey Marble Blue Marble Green Marble
Dimensions
Dimensions [mm]
Model
H B H1 B1 H2 L1 L B2
DPV 200x300 317 217 273 173 296 6.5 19.5 196
Color options
White Beige Grey Sky Blue Beige Marble Grey Marble Blue Marble Green Marble
• Enable quick and convenient access to • Universal mountings for left or right-side
concealed equipment and utility lines. opening.
Design
• Made of high-quality ABS plastic.
• Left or right-side opening.
• Equipped with a key lock.
Sample installations
Plastic access doors
with key lock
Dimensions
Dimensions [mm]
Model
H B H1 B1 H2 L1 L B2
DZ 150x300 317 167 273 123 297 5 25 147
DZ 250x400 417 267 373 223 397 5 25 247
DZ 300x500 517 317 473 273 497 5 25 297
DZ 300x600 617 317 573 273 597 5 25 297
DZ 400x500 517 417 473 373 497 5 25 397
DZ 400x600 617 417 573 373 597 5 25 397
Color options
White Beige Grey Sky Blue Beige Marble Grey Marble Blue Marble Green Marble
Sample installations
Dimensions
Dimensions [mm]
Model
H B H1 B1 H2 L1 L B2
DD 200x300 336 236 291 189 297 3 20 197
Color options
White Beige Grey Sky Blue Beige Marble Grey Marble Blue Marble Green Marble
Mounting
• Protected by national patents worldwide.
• Easy mounting using mortar or glue.
Design • Universal mountings for left or right-side
• Made of high-quality steel with a durable opening.
powder coating.
• Easy servicing.
• The use of zinc phosphate compound ensures
100 % coating integrity and provides a reliable
corrosion protection.
Dimensions
Metal access doors Dimensions [mm]
Model
H B H1 B2 H2 B1 L
DM 100x100 136.5 136.5 96.5 98.1 98.1 96.5 25
DM 150x150 186.5 186.5 146.5 148.1 148.1 146.5 25
DM 150x200 236.5 186.5 196.5 148.1 198.1 146.5 25
DM 150x250 286.5 186.5 246.5 148.1 248.1 146.5 25
DM 150x300 336.5 186.5 296.5 148.1 298.1 146.5 25
DM 200x200 236.5 236.5 196.5 198.1 198.1 196.5 25
DM 200x250 286.5 236.5 246.5 198.1 248.1 196.5 25
DM 200x300 336.5 236.5 296.5 198.1 298.1 196.5 25
DM 200x350 386.5 236.5 346.5 198.1 348.1 196.5 25
DM 200x400 436.5 236.5 396.5 198.1 398.1 196.5 25
DM 200x500 536.5 236.5 496.5 198.1 498.1 196.5 25
DM 225x300 336.5 261.5 296.5 223.1 298.1 221.5 25
Magnetic latch DM 225x590 626.5 261.5 586.5 223.1 588.1 221.5 25
DM 250x250 286.5 286.5 246.5 248.1 248.1 246.5 25
DM 250x300 336.5 286.5 296.5 248.1 298.1 246.5 25
DM 250x350 386.5 286.5 346.5 248.1 348.1 246.5 25
DM 250x400 436.5 286.5 396.5 248.1 398.1 246.5 25
DM 250x450 486.5 286.5 446.5 248.1 448.1 246.5 25
DM 300x200 236.5 336.5 196.5 298.1 198.1 296.5 25
DM 300x300 336.5 336.5 296.5 298.1 298.1 296.5 25
DM 300x400 436.5 336.5 396.5 298.1 398.1 296.5 25
DM 300x500 536.5 336.5 496.5 298.1 498.1 296.5 25
DM 300x600 636.5 336.5 596.5 298.1 598.1 296.5 25
DM 350x350 386.5 386.5 346.5 348.1 348.1 346.5 25
DM 400x400 436.5 436.5 396.5 398.1 398.1 396.5 25
DM 400x500 536.5 436.5 496.5 398.1 498.1 396.5 25
DM 400x600 636.5 436.5 596.5 398.1 598.1 396.5 25
DM 450x250 286.5 486.5 246.5 448.1 248.1 446.5 25
DM 450x450 486.5 486.5 446.5 448.1 448.1 446.5 25
DM 500x500 536.5 536.5 496.5 498.1 498.1 496.5 25
DM 500x600 636.5 536.5 596.5 498.1 598.1 496.5 25
DM 500x800 836.5 536.5 796.5 498.1 798.1 496.5 25
DM 555x555 591.5 591.5 551.5 553.1 553.1 551.5 25
DM 600x400 436.5 636.5 396.5 598.1 398.1 596.5 25
DM 600x600 636.5 636.5 596.5 598.1 598.1 596.5 25
DM 600x800 836.5 636.5 796.5 598.1 798.1 596.5 25
Color options
Design
• Universal mountings for left or right-side
opening.
• Made of high-quality steel with a durable • Easy servicing.
powder coating.
• The use of zinc phosphate compound ensures
100 % coating integrity and provides a reliable
corrosion protection.
Dimensions
Metal access doors Dimensions [mm]
Model
H B H1 B2 H2 B1 L
DMZ 100x100 136.5 136.5 96.5 98.1 98.1 96.5 25
DMZ 150x150 186.5 186.5 146.5 148.1 148.1 146.5 25
DMZ 150x200 236.5 186.5 196.5 148.1 198.1 146.5 25
DMZ 150x250 286.5 186.5 246.5 148.1 248.1 146.5 25
DMZ 150x300 336.5 186.5 296.5 148.1 298.1 146.5 25
DMZ 200x200 236.5 236.5 196.5 198.1 198.1 196.5 25
DMZ 200x250 286.5 236.5 246.5 198.1 248.1 196.5 25
DMZ 200x300 336.5 236.5 296.5 198.1 298.1 196.5 25
DMZ 200x350 386.5 236.5 346.5 198.1 348.1 196.5 25
DMZ 200x400 436.5 236.5 396.5 198.1 398.1 196.5 25
DMZ 200x500 536.5 236.5 496.5 198.1 498.1 196.5 25
DMZ 225x300 336.5 261.5 296.5 223.1 298.1 221.5 25
Key lock DMZ 225x590 626.5 261.5 586.5 223.1 588.1 221.5 25
DMZ 250x250 286.5 286.5 246.5 248.1 248.1 246.5 25
DMZ 250x300 336.5 286.5 296.5 248.1 298.1 246.5 25
DMZ 250x350 386.5 286.5 346.5 248.1 348.1 246.5 25
DMZ 250x400 436.5 286.5 396.5 248.1 398.1 246.5 25
DMZ 250x450 486.5 286.5 446.5 248.1 448.1 246.5 25
DMZ 300x200 236.5 336.5 196.5 298.1 198.1 296.5 25
DMZ 300x300 336.5 336.5 296.5 298.1 298.1 296.5 25
DMZ 300x400 436.5 336.5 396.5 298.1 398.1 296.5 25
DMZ 300x500 536.5 336.5 496.5 298.1 498.1 296.5 25
DMZ 300x600 636.5 336.5 596.5 298.1 598.1 296.5 25
DMZ 350x350 386.5 386.5 346.5 348.1 348.1 346.5 25
DMZ 400x400 436.5 436.5 396.5 398.1 398.1 396.5 25
DMZ 400x500 536.5 436.5 496.5 398.1 498.1 396.5 25
DMZ 400x600 636.5 436.5 596.5 398.1 598.1 396.5 25
DMZ 450x250 286.5 486.5 246.5 448.1 248.1 446.5 25
DMZ 450x450 486.5 486.5 446.5 448.1 448.1 446.5 25
DMZ 500x500 536.5 536.5 496.5 498.1 498.1 496.5 25
DMZ 500x600 636.5 536.5 596.5 498.1 598.1 496.5 25
DMZ 500x800 836.5 536.5 796.5 498.1 798.1 496.5 25
DMZ 555x555 591.5 591.5 551.5 553.1 553.1 551.5 25
DMZ 600x400 436.5 636.5 396.5 598.1 398.1 596.5 25
DMZ 600x600 636.5 636.5 596.5 598.1 598.1 596.5 25
DMZ 600x800 836.5 636.5 796.5 598.1 798.1 596.5 25
Color options
Mounting
Design
• Easy mounting using mortar or glue.
• Made of high-quality steel with a durable • Universal mountings for left or right-side
powder coating. opening.
• The use of zinc phosphate compound ensures • Easy servicing.
100 % coating integrity and provides a reliable
Dimensions
Color options
Design Mounting
• Made of high-quality steel with a durable • Easy mounting using mortar or glue.
powder coating. • Universal mountings for left or right-side
• The use of zinc phosphate compound ensures opening.
100 % coating integrity and provides a reliable • Easy servicing.
corrosion protection.
Dimensions
Metal access doors
with ventilation openings Dimensions [mm]
Model
H B H1 B2 H2 B1 L
DMV 100x100 136.5 136.5 96.5 98.1 98.1 96.5 25
DMV 150x150 186.5 186.5 146.5 148.1 148.1 146.5 25
DMV 150x200 236.5 186.5 196.5 148.1 198.1 146.5 25
DMV 150x250 286.5 186.5 246.5 148.1 248.1 146.5 25
DMV 150x300 336.5 186.5 296.5 148.1 298.1 146.5 25
DMV 200x200 236.5 236.5 196.5 198.1 198.1 196.5 25
DMV 200x250 286.5 236.5 246.5 198.1 248.1 196.5 25
DMV 200x300 336.5 236.5 296.5 198.1 298.1 196.5 25
DMV 200x350 386.5 236.5 346.5 198.1 348.1 196.5 25
DMV 200x400 436.5 236.5 396.5 198.1 398.1 196.5 25
DMV 225x300 336.5 261.5 296.5 223.1 298.1 221.5 25
DMV 225x590 626.5 261.5 586.5 223.1 588.1 221.5 25
DMV 250x250 286.5 286.5 246.5 248.1 248.1 246.5 25
DMV 250x300 336.5 286.5 296.5 248.1 298.1 246.5 25
DMV 250x350 386.5 286.5 346.5 248.1 348.1 246.5 25
DMV 250x400 436.5 286.5 396.5 248.1 398.1 246.5 25
DMV 250x450 486.5 286.5 446.5 248.1 448.1 246.5 25
DMV 300x200 236.5 336.5 296.5 298.1 198.1 196.5 25
DMV 300x300 336.5 336.5 296.5 298.1 298.1 296.5 25
DMV 300x400 436.5 336.5 396.5 298.1 398.1 296.5 25
DMV 300x500 536.5 336.5 496.5 298.1 498.1 296.5 25
DMV 300x600 636.5 336.5 596.5 298.1 598.1 296.5 25
DMV 350x350 386.5 386.5 346.5 348.1 348.1 346.5 25
DMV 400x400 436.5 436.5 396.5 398.1 398.1 396.5 25
DMV 400x500 536.5 436.5 496.5 398.1 498.1 396.5 25
DMV 400x600 636.5 436.5 596.5 398.1 598.1 396.5 25
DMV 450x250 286.5 486.5 446.5 448.1 248.1 246.5 25
DMV 450x450 486.5 486.5 446.5 448.1 448.1 446.5 25
DMV 500x500 536.5 536.5 496.5 498.1 498.1 496.5 25
DMV 500x600 636.5 536.5 596.5 498.1 598.1 496.5 25
DMV 500x800 836.5 536.5 796.5 498.1 798.1 496.5 25
DMV 555x555 591.5 591.5 551.5 553.1 553.1 551.5 25
DMV 600x400 436.5 636.5 596.5 598.1 398.1 396.5 25
DMV 600x600 636.5 636.5 596.5 598.1 598.1 596.5 25
DMV 600x800 836.5 636.5 596.5 598.1 798.1 796.5 25
Color options
• Designed for wall installation and ceramic tile • Magnetic attachment of plate to the frame.
attachment. • Press gently to open and close or use a cup
plunger.
• Enable quick and convenient access to
concealed equipment and utility lines. • A wide range of sizes.
Sample installations
Dimensions
Dimensions [mm]
Model
B H B2 H2 B1 H1 L
DKP 150x150 156 156 145 145 153 153 30
DKP 150x200 156 206 145 195 153 203 30
DKP 150x300 156 306 145 295 153 303 30
DKP 200x200 206 206 195 195 203 203 30
DKP 200x250 206 256 195 245 203 253 30
DKP 200x300 206 306 195 295 203 303 30
DKP 200x350 206 356 195 345 203 353 30
DKP 200x400 206 406 195 395 203 403 30
DKP 200x450 206 456 195 445 203 453 30
DKP 200x500 206 506 195 495 203 503 30
DKP 250x250 256 256 245 245 253 253 30
DKP 250x300 256 306 245 295 253 303 30
DKP 250x350 256 356 245 345 253 353 30
DKP 250x400 256 406 245 395 253 403 30
DKP 300x300 306 306 295 295 303 303 30
DKP 300x350 306 356 295 345 303 353 30
DKP 300x400 306 406 295 395 303 403 30
DKP 300x450 306 456 295 445 303 453 30
DKP 300x500 306 506 295 495 303 503 30
DKP 400x400 406 406 395 395 403 403 30
• Designed for wall installation and ceramic tile • Magnetic attachment of plate to the frame.
attachment. • Press gently to open and close or use a cup
plunger.
• Enable quick and convenient access to
concealed equipment and utility lines. • A wide range of sizes.
Sample Installations
Access doors on a metal frame recessed
for ceramic tiles
Dimensions
Dimensions [mm]
Model
B H B2 H2 L
DKM 150x150 163.6 163.6 150 150 26
DKM 150x200 163.6 213.6 150 200 26
DKM 150x250 163.6 263.6 150 250 26
DKM 150x300 163.6 313.6 150 300 26
DKM 200x200 213.6 213.6 200 200 26
DKM 200x250 213.6 263.6 200 250 26
DKM 200x300 213.6 313.6 200 300 26
DKM 200x350 213.6 363.6 200 350 26
DKM 200x400 213.6 413.6 200 400 26
DKM 200x450 213.6 463.6 200 450 26
DKM 200x500 213.6 513.6 200 500 26
DKM 250x250 263.6 263.6 250 250 26
DKM 250x300 263.6 313.6 250 300 26
DKM 250x350 263.6 363.6 250 350 26
DKM 250x400 263.6 413.6 250 400 26
DKM 300x300 313.6 313.6 300 300 26
DKM 300x350 313.6 363.6 300 350 26
DKM 300x400 313.6 413.6 300 400 26
DKM 300x450 313.6 463.6 300 450 26
DKM 300x500 313.6 513.6 300 500 26
DKM 400x400 413.6 413.6 400 400 26
DKM 400x500 413.6 513.6 400 500 26
DKM 500x500 513.6 513.6 500 500 26
DKM 600x600 613.6 613.6 600 600 26
• Designed for plasterboard walls and ceilings • Press gently to open and close.
12.5 and 15 mm thick. • A wide range of sizes.
• Enable quick and convenient access to • Custom sizes are available upon request.
concealed equipment and utility lines.
Mounting
• Suitable for high-humidity areas.
• Protected by national patents worldwide. • The doors are attached to aluminum profiles
on self-tapping screws and flushed up with
plasterboard on the front.
Design
• Universal mountings for left or right-side
• The main structural frame and panel frame are opening.
made of aluminum profile. • Easy servicing.
• The special mechanism ensures secure locking,
large-size doors are equipped with double locks.
Sample Installations
Access doors for plasterboard
application
Dimensions
Dimensions [mm]
Model
H/B H1/B1 B2 L L1 Number of locks
DG 200x200 260 196 204 15 55 1
DG 300x300 360 296 304 15 55 1
The special mechanism provides
for secure locking DG 400x400 460 396 404 15 55 2
DG 500x500 560 496 504 15 55 2
DG 600x600 660 596 604 15 55 2
Dimensions
Dimensions [mm]
Model
B B1 H H1
DPM 300x300 336.5 296.5 298 200
Quality and functionality of ventilation and air conditioning depends a lot on end air distribution, supply and intake devices.
Profiplast are the professional air distribution systems with a great product variety to implement any technical and project designs that are featured with
extreme durability.
The benefits of Profiplast products are due to the use of specially designed plastics . These offer the following advantages to consumers: Profiplast grilles
produce no condensation, have excellent sound-insulating and corrosion-resistant properties. Moreover they are non-flammable and are easy to paint.
Plastic properties
Generally, plastic is the most widely used construction material due to the beneficial properties:
· Durability combined with a maintenance-free service life
· Extremely low heat conductivity and good sound insulation
· UV-resistance
· Good hygienic properties and easy to clean
· Detergent resistant
· The best balance of price and quality
· Corrosion- and decay-resistance
· Eco-friendly because it is 100 % recyclable
Design
• Made of high-quality plastic.
• Weather- and temperature-resistant.
• Removable spring-loaded vanes for simple maintenance.
• Simple and quick mounting.
Colour modifications
UV-resistant Waterproof Heat-resistant Frostproof Easy mounting Fire-resistant Antibacterial Impact-resistant Durable Maintenance-free
100
Pressure, ΔP [Pa]
80
Pa
60
50 dBA
40
30
20
10
8
6
5
4
3
2 3 4 5 6 7 8 9 10
Speed, V [m/s]
Dimensions [mm]
Model Air pass [m2]
H L h l
NUN 200×200 214 214 200 200 0.0066
NHN 300×200 214 303 200 289 0.0104
NHN 350×200 214 363 200 349 0.0131
NHN 400×200 214 392 200 378 0.0143
NHN 450×200 214 452 200 438 0.0170
NHN 500×200 214 512 200 498 0.0196
NHN 600×200 214 602 200 588 0.0235
NUN 300×300 303 303 289 289 0.0169
NHN 350×300 303 363 289 349 0.0212
NHN 400×300 303 392 289 378 0.0232
NHN 450×300 303 452 289 438 0.0275
NHN 500×300 303 512 289 498 0.0317
NHN 600×300 303 602 289 588 0.0381
NUN 350×350 363 363 349 349 0.0267
NHN 400×350 363 392 349 378 0.0292
NHN 450×350 363 452 349 438 0.0346
NHN 500×350 363 512 349 498 0.0399
NHN 600×350 363 602 349 588 0.0480
NUN 400×400 392 392 378 378 0.0321
NHN 450×400 392 452 378 438 0.0380
NHN 500×400 392 512 378 498 0.0439
NHN 600×400 392 602 378 588 0.0527
NUN 450×450 452 452 438 438 0.0451
NHN 500×450 452 512 438 498 0.0521
NHN 600×450 452 602 438 588 0.0626
NUN 500×500 512 512 498 498 0.0603
NHN 600×500 512 602 498 588 0.0724
Dimensions [mm]
Model Air pass [m2]
H L h l
NUN 580×580 599 599 585 585 0.0755
NUN 600×600 602 602 588 588 0.0764
NHN 900×200 214 912 200 898 0.0341
NHN 900×300 303 912 289 898 0.0553
NHN 900×350 363 912 349 898 0.0696
NHN 900×400 392 912 378 898 0.0765
NHN 900×450 452 912 438 898 0.0909
NHN 900×500 512 912 498 898 0.1052
NHN 900×600 602 912 588 898 0.1266
Dimensions [mm]
Model Air pass [m2]
H L h l
NHN 1200×300 303 1214 289 1200 0.0719
NHN 1200×350 363 1214 349 1200 0.0906
NHN 1200×400 392 1214 378 1200 0.0996
NHN 1200×450 452 1214 438 1200 0.1182
NHN 1200×500 512 1214 498 1200 0.1369
NHN 1200×600 602 1214 588 1200 0.1648
NHN 1350×300 303 1364 289 1350 0.0825
NHN 1350×350 363 1364 349 1350 0.1039
NHN 1350×400 392 1364 378 1350 0.1143
NHN 1350×450 452 1364 438 1350 0.1357
NHN 1350×500 512 1364 498 1350 0.1570
NHN 1350×600 602 1364 588 1350 0.1891
Dimensions [mm]
Model Air pass [m2]
H L h l
NHN 1500×300 303 1514 289 1500 0.0884
NHN 1500×350 363 1514 349 1500 0.1113
NHN 1500×400 392 1514 378 1500 0.1224
NHN 1500×450 452 1514 438 1500 0.1453
NHN 1500×500 512 1514 498 1500 0.1683
NHN 1500×600 602 1514 588 1500 0.2027
Design
• Made of high-quality plastic.
• Weather- and temperature-resistant.
• Removable spring-loaded vanes for simple maintenance.
• Simple and quick mounting.
Colour modifications
UV-resistant Waterproof Heat-resistant Frostproof Easy mounting Fire-resistant Antibacterial Impact-resistant Durable Maintenance-free
100
Pressure, ΔP [Pa]
80
Pa
60
50 dBA
40
30
20
10
8
6
5
4
3
2 3 4 5 6 7 8 9 10
Speed, V [m/s]
Dimensions [mm]
Model Air pass [m2]
H L h l
NUN 200×200 214 214 200 200 0.0066
NVN 300×200 214 303 200 289 0.0106
NVN 350×200 214 363 200 349 0.0134
NVN 400×200 214 392 200 378 0.0147
NVN 450×200 214 452 200 438 0.0174
NVN 500×200 214 512 200 498 0.0202
NVN 600×200 214 602 200 588 0.0243
NUN 300×300 303 303 289 289 0.0169
NVN 350×300 303 363 289 349 0.0213
NVN 400×300 303 392 289 378 0.0234
NVN 450×300 303 452 289 438 0.0278
NVN 500×300 303 512 289 498 0.0322
NVN 600×300 303 602 289 588 0.0387
NUN 350×350 363 363 349 349 0.0267
NVN 400×350 363 392 349 378 0.0293
NVN 450×350 363 452 349 438 0.0348
NVN 500×350 363 512 349 498 0.0402
NVN 600×350 363 602 349 588 0.0484
NUN 400×400 392 392 378 378 0.0321
NVN 450×400 392 452 378 438 0.0531
NVN 500×400 392 512 378 498 0.0441
NVN 600×400 392 602 378 588 0.0381
NUN 450×450 452 452 438 438 0.0451
NVN 500×450 452 512 438 498 0.0629
NVN 600×450 452 602 438 588 0.0522
NUN 500×500 512 512 498 498 0.0603
NVN 600×500 512 602 498 588 0.0726
NUN 580×580 599 599 585 585 0.0872
NUN 600×600 602 602 588 588 0.0862
Dimensions [mm]
Model Air pass [m2]
H L h l
NVN 900×200 214 934 200 920 0.0365
NVN 900×300 303 934 289 920 0.0581
NVN 1200×300 303 1234 289 1220 0.0800
NVN 900×350 363 934 349 920 0.0727
NVN 1200×350 363 1234 349 1220 0.1001
NVN 900×400 392 934 378 920 0.0798
NVN1200×400 392 1234 378 1220 0.1098
NVN 900×450 452 934 438 920 0.0944
NVN 1200×450 452 1234 438 1220 0.1299
NVN 900×500 512 934 498 920 0.1090
NVN 1200×500 512 1234 498 1220 0.1500
NVN 900×600 602 934 588 920 0.1309
NVN 1200×600 602 1234 588 1220 0.1801
Dimensions [mm]
Model Air pass [m2]
H L h l
NVN 1350×300 303 1377 289 1363 0.0857
NVN 1500×300 303 1559 289 1545 0.0989
NVN 1350×350 363 1377 349 1363 0.1072
NVN 1500×350 363 1559 349 1545 0.1238
NVN 1350×400 392 1377 378 1363 0.1176
NVN 1500×400 392 1559 378 1545 0.1358
NVN 1350×450 452 1377 438 1363 0.1391
NVN 1500×450 452 1559 438 1545 0.1606
NVN 1350×500 512 1377 498 1363 0.1606
NVN 1500×500 512 1559 498 1545 0.1854
NVN 1350×600 602 1377 588 1363 0.1928
NVN 1500×600 602 1559 588 1545 0.2227
GR Application
series • Exhaust ventilation, heating and air conditioning networks in industrial, commercial
and domestic premises.
Design
• Made of high-quality plastic.
• Weather- and temperature-resistant.
• Removable spring-loaded vanes for simple maintenance.
• Simple and quick mounting.
Colour modifications
UV-resistant Waterproof Heat-resistant Frostproof Easy mounting Fire-resistant Antibacterial Impact-resistant Durable Maintenance-free
100
Pressure, ΔP [Pa]
80
Pa
60
50 dBA
40
30
20
10
8
6
5
4
3
2 3 4 5 6 7 8 9 10
Speed, V [m/s]
Dimensions [mm]
Model Air pass [m2]
H L h l
GR 300×300 303 303 289 289 0.0543
GR 350×300 303 362 289 348 0.0677
GR 400×300 303 422 289 408 0.1013
GR 450×300 303 464 289 450 0.1132
GR 500×300 303 514 289 500 0.1530
GR 600×300 303 598 289 584 0.1816
GR 350×350 362 362 348 348 0.1512
GR 400×350 362 422 348 408 0.0813
GR 500×350 362 514 348 500 0.1022
GR 600×350 362 598 348 584 0.1212
GR 400×400 422 422 408 408 0.0813
GR 450×400 422 464 408 450 0.1132
GR 500×400 422 514 408 500 0.1274
GR 600×400 422 598 408 584 0.1816
GR 600×600 598 598 584 584 0.1816
Dimensions [mm]
Model Air pass [m2]
H L h l
GR 900×300 303 914 289 900 0.1882
GR 1200×300 303 1214 289 1200 0.2563
GR 900×350 362 914 348 900 0.2347
GR 1200×350 362 1214 348 1200 0.3196
GR 900×400 422 914 408 900 0.2819
GR 1200×400 422 1214 408 1200 0.3840
GR 900×600 598 914 584 900 0.4205
GR 1200×600 598 1214 584 1200 0.5727
Dimensions [mm]
Model Air pass [m2]
H L h l
GR 1350×300 303 1364 289 1350 0.2856
GR 1500×300 303 1514 289 1500 0.3197
GR 1350×350 362 1364 348 1350 0.3561
GR 1500×350 362 1514 348 1500 0.3986
GR 1350×400 422 1364 408 1350 0.4278
GR 1500×400 422 1514 408 1500 0.4788
GR 1350×600 598 1364 584 1350 0.6381
GR 1500×600 598 1514 584 1500 0.7142
RD Application
series • Supply and exhaust ventilation, heating and air conditioning networks in industrial,
commercial and domestic premises.
Design
• Made of high-quality plastic.
• Weather- and temperature-resistant.
• Simple and quick mounting.
Colour modifications
roof
tant Heat-resistant
Waterproof
UV-resistant Heat-resistant
Frostproof
Waterproof Easy
Frostproof
Heat-resistant
mounting Easy
Fire-resistant
mounting
Frostproof Fire-resistant
Antibacterial
Easy mounting Impact-resistant
Antibacterial
Fire-resistant Impact-resistant
Durable
Antibacterial Maintenance-free
Impact-resistant
Durable Maintenance-free
Durable Maintenance-free
100
Pressure, ΔP [Pa]
80
Pa
60
50 dBA
40
30
20
10
8
6
5
4
3
2 3 4 5 6 7 8 9 10
Speed, V [m/s]
Dimensions [mm]
Model
L H b
RD 600/1 M 300 300 10
RD 600/2 M 600 300 10
RD 600 M 600 600 10
RD 600/6 M 600 900 10
RD 600/8 M 600 1200 10
RD 600/1 L 300 300 12
RD 600/2 L 600 300 12
RD 600 L 600 600 12
RD 600/6 L 600 900 12
RD 600/8 L 600 1200 12
RD 600/1 300 300 15
RD 600/2 600 300 15
RD 600 600 600 15
RD 600/6 600 900 15
RD 600/8 600 1200 15
ND Application
series • Supply and exhaust ventilation, heating and air conditioning networks in industrial,
commercial and domestic premises.
Design
• Made of high-quality plastic.
• Weather- and temperature-resistant.
• Simple and quick mounting.
Colour modifications
UV-resistant Waterproof Heat-resistant Frostproof Easy mounting Fire-resistant Antibacterial Impact-resistant Durable Maintenance-free
100
Pressure, ΔP [Pa]
80
Pa
60
50 dBA
40
30
20
10
8
6
5
4
3
2 3 4 5 6 7 8 9 10
Speed, V [m/s]
Dimensions [mm]
Model Air pass [m2]
H L h l
ND 350×350 362 362 348 348 0.0729
ND 650×350 362 660 348 646 0.1458
ND 950×350 362 958 348 944 0.2187
ND 1250×350 362 1256 348 1242 0.2916
ND 650×650 660 660 646 646 0.2916
ND 950×650 660 958 646 944 0.4374
ND 1250×650 660 1256 646 1242 0.5832
NK-3 Application
series • Supply and exhaust ventilation, heating and air conditioning networks in industrial,
commercial and domestic premises.
Design
• Made of high-quality plastic.
• Weather- and temperature-resistant.
• Removable spring-loaded vanes for simple maintenance.
• Simple and quick mounting.
• Uniform air flow distribution.
UV-resistant Waterproof Heat-resistant Frostproof Easy mounting Fire-resistant Antibacterial Impact-resistant Durable Maintenance-free
NK H2V1 NK H1V2
100
Pressure, ΔP [Pa]
80
Pa
60
50 dBA
40
30
20
10
8
6
5
4
3
2 3 4 5 6 7 8 9 10
Speed, V [m/s]
Dimensions [mm]
Model Air pass [m2]
H L h l
NVNK H1V1 580×580 598 598 584 584 0.0755
Dimensions [mm]
Model Air pass [m2]
H L h l
NK H2V1 1200×600 602 1214 588 1200 0.1718
NK H2V1 1350×600 602 1364 588 1350 0.1966
NK H2V1 1500×600 602 1514 588 1500 0.2213
Dimensions [mm]
Model Air pass [m2]
H L h l
NK H1V2 900×300 303 929 289 915 0.0562
NK H1V2 1200×300 303 1214 289 1200 0.9069
NK H1V2 900×400 392 929 378 915 0.0774
NK H1V2 1200×400 392 1214 378 1200 0.1064
NK H1V2 900×600 602 929 588 915 0.1273
NK H1V2 1200×600 602 1214 588 1200 0.1750
NK H1V2 1350×600 602 1364 588 1350 0.2002
NK H1V2 1500×600 602 1514 588 1500 0.2253
NK-4 Application
series • Supply and exhaust ventilation, heating and air conditioning networks in industrial,
commercial and domestic premises.
Design
• Made of high-quality plastic.
• Weather- and temperature-resistant.
• Removable spring-loaded vanes for simple maintenance.
• Simple and quick mounting.
• Uniform air flow distribution.
Colour modifications
UV-resistant Waterproof Heat-resistant Frostproof Easy mounting Fire-resistant Antibacterial Impact-resistant Durable Maintenance-free
100
Pressure, ΔP [Pa]
80
Pa
60
50 dBA
40
30
20
10
8
6
5
4
3
2 3 4 5 6 7 8 9 10
Speed, V [m/s]
Dimensions [mm]
Model Air pass [m2]
H L h l
NK H2V2 550×550 570 570 556 556 0.0422
NK H2V2 600×600 630 630 616 616 0.0577
NK H2V2 900×600 630 930 616 619 0.0982
Series Application
ONG / ONV • Supply and exhaust ventilation, heating
and air conditioning networks in industrial,
commercial and domestic premises.
Design
• Made of high-quality extruded aluminium.
Modifications
• Available modifications with an air flow regulator
(R) and an adapter (A) for connection to air ducts.
Designation:
ΔP – pressure loss [Pa]
LWA – sound power level [dBA]
LWAO – sound power level for air pass 0.1 m2 [dBA]
K – correction factor for sound power level calculation depending on air pass [dBA]
Sap – air pass [m2]
V – rated speed [m/s]
Order code
LxH
Series Application
ONL • Supply and exhaust ventilation, heating
and air conditioning networks in industrial,
commercial and domestic premises.
Design
• Made of high-quality extruded aluminium.
Modifications
• Available modifications with an air flow regulator
(R) and an adapter (A) for connection to air ducts.
Single-row linear horizontal ventilation grille
with fixed vanes • Available modifications with versatile fixing (u)
or with special springs (p) for fast mounting.
Designation:
ΔP – pressure loss [Pa]
LWA – sound power level [dBA]
LWAO – sound power level for air pass 0.1 m2 [dBA]
K – correction factor for sound power level calculation depending on air pass [dBA]
Sap – air pass [m2]
V – rated speed [m/s]
Series Application
ONF/ONFS • Supply and exhaust ventilation, heating
and air conditioning networks in industrial,
commercial and domestic premises.
Design
• Made of high-quality extruded aluminium.
Modifications
• Available modifications with an
adapter (A) for connection to air ducts.
vane deflection
angle – 45°
Length L [mm]
Height H [mm]
100 150 200 250 300 350 400 450 500 600 700 800 900 1000
100 0.004 0.007 0.010 0.012 0.015 0.018 0.021 0.024 0.027 0.033 0.039 0.045 0.051 0.057
150 0.007 0.010 0.015 0.018 0.023 0.027 0.031 0.035 0.039 0.047 0.055 0.064 0.072 0.080
200 0.010 0.015 0.021 0.026 0.033 0.038 0.045 0.051 0.058 0.070 0.081 0.093 0.105 0.115
250 0.012 0.018 0.026 0.032 0.041 0.047 0.055 0.062 0.070 0.084 0.098 0.106 0.113 0.128
300 0.015 0.023 0.033 0.041 0.051 0.059 0.069 0.077 0.086 0.096 0.115 0.132 0.149 0.168
350 0.017 0.026 0.038 0.047 0.059 0.068 0.080 0.090 0.099 0.111 0.132 0.151 0.170 0.193
400 0.020 0.030 0.044 0.054 0.069 0.079 0.093 0.103 0.117 0.142 0.166 0.189 0.212 0.237
450 0.023 0.035 0.051 0.062 0.080 0.090 0.107 0.117 0.131 0.160 0.186 0.214 0.239 0.265
500 0.026 0.039 0.056 0.070 0.089 0.100 0.119 0.130 0.145 0.178 0.206 0.238 0.265 0.293
600 0.031 0.047 0.067 0.084 0.105 0.121 0.142 0.158 0.173 0.214 0.246 0.287 0.318 0.349
700 0.036 0.055 0.078 0.094 0.124 0.145 0.170 0.184 0.203 0.251 0.288 0.336 0.372 0.408
800 0.042 0.063 0.090 0.112 0.141 0.163 0.190 0.211 0.232 0.288 0.330 0.385 0.426 0.467
900 0.048 0.072 0.103 0.129 0.160 0.185 0.228 0.238 0.262 0.325 0.372 0.435 0.481 0.527
1000 0.053 0.079 0.113 0.141 0.177 0.204 0.239 0.266 0.292 0.361 0.414 0.484 0.536 0.587
Designation:
ΔP – pressure loss [Pa]
LWA – sound power level [dBA]
LWAO – sound power level for air pass 0.1 m2 [dBA]
K – correction factor for sound power level calculation depending on air pass [dBA]
Sap – air pass [m2]
V – rated speed [m/s]
V [m/s]
ΔP f(V) [Pa]
Lwao [dBA]
Order code
LxH
Grille coating:
"___ " – colour* (white by default)
"Anodized"
Series Application
ONK • Supply and exhaust ventilation, heating
and air conditioning networks in industrial,
commercial and domestic premises.
Design
• Made of high-quality extruded aluminium.
Modifications
• Available modifications with an air flow regulator
Single-row sectional ventilation grille with fixed vanes (R) and an adapter (A) for connection to air ducts.
450 0.117 0.131 0.146 0.160 0.173 0.186 0.200 0.214 0.226 0.239 0.252 0.265
500 0.130 0.145 0.162 0.178 0.192 0.206 0.222 0.238 0.252 0.265 0.279 0.293
550 0.144 0.159 0.178 0.196 0.211 0.226 0.244 0.263 0.277 0.292 0.306 0.321
600 0.158 0.173 0.194 0.214 0.230 0.246 0.267 0.287 0.303 0.318 0.334 0.349
650 0.171 0.188 0.210 0.233 0.250 0.267 0.289 0.312 0.328 0.345 0.362 0.379
700 0.184 0.203 0.227 0.251 0.270 0.288 0.312 0.336 0.354 0.372 0.390 0.408
750 0.198 0.217 0.243 0.270 0.289 0.309 0.335 0.361 0.380 0.399 0.418 0.438
800 0.211 0.232 0.260 0.288 0.309 0.330 0.358 0.385 0.406 0.426 0.447 0.467
850 0.225 0.247 0.277 0.306 0.329 0.351 0.380 0.410 0.432 0.453 0.475 0.497
900 0.238 0.262 0.293 0.325 0.348 0.372 0.403 0.435 0.458 0.481 0.504 0.527
950 0.252 0.277 0.310 0.343 0.368 0.393 0.426 0.459 0.484 0.508 0.533 0.557
1000 0.266 0.292 0.327 0.361 0.388 0.414 0.449 0.484 0.510 0.536 0.561 0.587
Designation:
ΔP – pressure loss [Pa]
LWA – sound power level [dBA]
LWAO – sound power level for air pass 0.1 m2 [dBA]
K – correction factor for sound power level calculation depending on air pass [dBA]
Sap – air pass [m2]
V – rated speed [m/s]
Order code
LxH
Grille coating:
"___ " – colour* (white by default)
"Anodized"
Grille type:
ONK – single-row sectional grille with fixed vanes
Series Application
ORG / ORV • Supply and exhaust ventilation, heating
and air conditioning networks in industrial,
commercial and domestic premises.
Design
• Made of high-quality extruded aluminium.
Modifications
• Available modifications with an air flow regulator
(R) and an adapter (A) for connection to air ducts.
Designation:
ΔPp – pressure loss at various vane positions [Pa]
ΔP – pressure loss [Pa]
Kp – correction factor for pressure loss calculation depending on louvre deflection
V [m/s] angle
ΔP f(V) [Pa] LWA – sound power level [dBA]
Lwao [dBA]
LWAO – sound power level for air pass 0.1 m2 [dBA]
K – correction factor for sound power level calculation depending on air pass [dBA]
Sap – air pass [m2]
V – rated speed [m/s]
Order code
LxH
Grille coating:
Grille type:
"___ " – colour* (white by default)
ORG – single-row grille with individually adjustable horizontal
"Anodized"
louvres
ORV – single-row grille with individually adjustable vertical Accessories:
louvres ___ – no
R – air flow regulator
A – adapter
Series Application
ORK • Supply and exhaust ventilation, heating and air
conditioning networks in industrial, commercial and
domestic premises.
Design
• Made of high-quality extruded aluminium.
Modifications
• Available modifications with an air flow regulator (R) and
an adapter (A) for connection to air ducts.
Single-row sectional ventilation grille with • Available modifications with versatile fixing (u) for fast
450 0.148 0.171 0.182 0.194 0.212 0.230 0.250 0.269 0.284 0.298 0.313 0.327
500 0.166 0.187 0.197 0.208 0.232 0.257 0.279 0.301 0.317 0.333 0.349 0.365
550 0.183 0.203 0.213 0.223 0.253 0.283 0.308 0.332 0.350 0.367 0.385 0.403
600 0.2 0.219 0.228 0.237 0.274 0.31 0.337 0.363 0.383 0.402 0.422 0.441
650 0.217 0.244 0.257 0.270 0.303 0.337 0.366 0.395 0.414 0.433 0.452 0.471
700 0.235 0.269 0.286 0.303 0.333 0.364 0.395 0.426 0.445 0.463 0.482 0.500
750 0.252 0.294 0.314 0.335 0.363 0.390 0.424 0.458 0.476 0.494 0.512 0.530
800 0.269 0.319 0.343 0.368 0.393 0.417 0.453 0.489 0.507 0.524 0.542 0.559
850 0.286 0.339 0.365 0.392 0.418 0.444 0.482 0.520 0.542 0.563 0.585 0.606
900 0.304 0.359 0.387 0.415 0.443 0.471 0.511 0.552 0.577 0.602 0.627 0.653
950 0.321 0.380 0.409 0.439 0.468 0.497 0.540 0.583 0.612 0.641 0.670 0.699
1000 0.338 0.4 0.431 0.462 0.493 0.524 0.569 0.614 0.647 0.68 0.713 0.746
Designation:
ΔPp – pressure loss at various vane positions [Pa]
ΔP – pressure loss [Pa]
Kp – correction factor for pressure loss calculation depending on louvre deflection
V [m/s] angle
ΔP f(V) [Pa] LWA – sound power level [dBA]
Lwao [dBA]
LWAO – sound power level for air pass 0.1 m2 [dBA]
K – correction factor for sound power level calculation depending on air pass [dBA]
Sap – air pass [m2]
V – rated speed [m/s]
Order code
LxH
Series Application
DR • Supply and exhaust ventilation, heating
and air conditioning networks in industrial,
commercial and domestic premises.
Design
• Made of high-quality extruded aluminium.
Modifications
• Available modifications with an air flow regulator
(R) and an adapter (A) for connection to air ducts.
Length L [mm]
Height H [mm]
100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000
100 0.004 0.008 0.014 0.018 0.023 0.027 0.033 0.038 0.044 0.046 0.049 0.055 0.061 0.067 0.072 0.076 0.080 0.084 0.088
150 0.015 0.020 0.026 0.031 0.037 0.042 0.044 0.047 0.049 0.052 0.058 0.064 0.070 0.075 0.079 0.083 0.087 0.091
200 0.025 0.034 0.040 0.048 0.054 0.063 0.072 0.077 0.082 0.089 0.096 0.104 0.112 0.118 0.124 0.130 0.136
250 0.045 0.053 0.064 0.072 0.082 0.093 0.099 0.105 0.112 0.118 0.128 0.138 0.146 0.153 0.161 0.168
300 0.062 0.075 0.084 0.098 0.113 0.121 0.129 0.140 0.150 0.163 0.175 0.185 0.194 0.204 0.213
350 0.091 0.102 0.116 0.130 0.140 0.150 0.161 0.171 0.186 0.200 0.211 0.222 0.232 0.243
400 0.118 0.137 0.155 0.167 0.179 0.191 0.203 0.221 0.238 0.251 0.264 0.276 0.289
450 0.148 0.171 0.182 0.194 0.212 0.230 0.250 0.269 0.284 0.298 0.313 0.327
500 0.187 0.197 0.208 0.232 0.257 0.279 0.301 0.317 0.333 0.349 0.365
550 0.199 0.223 0.253 0.283 0.308 0.332 0.350 0.367 0.385 0.403
600 0.237 0.274 0.310 0.337 0.363 0.383 0.402 0.422 0.441
1000 0.746
Designation:
ΔPp – pressure loss at various vane positions [Pa]
ΔP – pressure loss [Pa]
Kp – correction factor for pressure loss calculation depending on louvre deflection
V [m/s] angle
ΔP f(V) [Pa] LWA – sound power level [dBA]
Lwao [dBA]
LWAO – sound power level for air pass 0.1 m2 [dBA]
K – correction factor for sound power level calculation depending on air pass [dBA]
Sap – air pass [m2]
V – rated speed [m/s]
Order code
LxH
Grille fixation:
u – versatile
Series Application
DP • Supply and exhaust ventilation, heating
and air conditioning networks in industrial,
commercial and domestic premises.
Design
• Made of high-quality extruded aluminium.
Modifications
• Available modifications with an air flow regulator
(R) and an adapter (A) for connection to air ducts.
Length L [mm]
ΔP [Pa]
- 258х258
- 326х326
- 394x394
- 462x462
5 - 530x530
6 - 600x600
Designation:
ΔP – pressure loss [Pa]
Q – air flow [m3/h]
LWA –sound power level [dBA]
Q [m3/s]
ΔP f(Q) [Pa]
Lwao [dBA]
Order code
LxH
L - 50 x H - 50
l+6xh+6
lxh
LxH
Series Application
DPp • Supply and exhaust ventilation, heating
and air conditioning networks in industrial,
commercial and domestic premises.
Design
• Made of high-quality extruded aluminium.
Modifications
• Available modifications with an air flow regulator
(R) and an adapter (A) for connection to air ducts.
- 595х140
- 595х215
- 595x290
- 595x365
Designation:
ΔP – pressure loss [Pa]
Q – air flow [m3/h]
Q [m /h]
3
Order code
AxB
Series Application
DS • Supply and exhaust ventilation, heating
and air conditioning networks in industrial,
commercial and domestic premises.
Design
• Made of high-quality extruded aluminium.
Slit diffuser
Modifications
• Available modifications with an adapter
(A) for connection to air ducts.
Number of
H, mm 200 300 400 500 600 700 800 900 1000 1200 1400 1500 1600 1800 2000
slits
1 62 0.0043 0.0067 0.009 0.0114 0.0138 0.0162 0.0186 0.0209 0.0233 0.0281 0.0328 0.0352 0.0376 0.0423 0.0471
2 106 0.0086 0.0134 0.0180 0.0228 0.0276 0.0324 0.0372 0.0418 0.0466 0.0562 0.0656 0.0704 0.0752 0.0846 0.0942
3 151 0.0129 0.0201 0.0270 0.0342 0.0414 0.0486 0.0558 0.0627 0.0699 0.0843 0.0984 0.1056 0.1128 0.1269 0.1413
4 195 0.0172 0.0268 0.0360 0.0456 0.0552 0.0648 0.0744 0.0836 0.0932 0.1124 0.1312 0.1408 0.1504 0.1692 0.1884
5 239 0.0215 0.0335 0.0450 0.0570 0.0690 0.0810 0.0930 0.1045 0.1165 0.1405 0.1640 0.1760 0.1880 0.2115 0.2355
6 283 0.0258 0.0402 0.0540 0.0684 0.0828 0.0972 0.1116 0.1254 0.1398 0.1686 0.1968 0.2112 0.2256 0.2538 0.2826
Designation:
ΔPp – pressure loss at various vane positions [Pa]
ΔP – pressure loss [Pa]
Kp – correction factor for pressure loss calculation depending on louvre deflection
angle
V [m/s] LWA – sound power level [dBA]
∆Pf (V) [Pа]
LWAO [dBA]
LWAO – sound power level for air pass 0.1 m2 [dBA]
K – correction factor for sound power level calculation depending on air pass [dBA]
Sap – air pass [m2]
V – rated speed [m/s]
Order code
xLxH
Grille coating:
"___ " – colour* (white by default)
"Anodized"
Grille type:
DS – slit diffuser
Accessories:
Number of slits:
___ – no
1, 2, 3, 4, 5, 6
A – adapter
Series Application
RP • Supply and exhaust ventilation, heating
and air conditioning networks in industrial,
commercial and domestic premises.
Design
• Made of high-quality extruded aluminium shape and
an insert piece of perforated steel or expanded mesh.
Modifications
• Available modifications with an adapter
Exhaust ventilation grille with a mesh insert (A) for connection to air ducts.
300 0.058 0.065 0.071 0.099 0.112 0.139 0.159 0.176 0.199 0.221
350 0.067 0.087 0.110 0.123 0.153 0.175 0.211 0.231 0.252
400 0.102 0.120 0.134 0.166 0.190 0.245 0.264 0.282
450 0.143 0.162 0.201 0.230 0.269 0.299 0.328
500 0.184 0.228 0.261 0.305 0.338 0.371
600 0.283 0.324 0.378 0.419 0.460
700 0.370 0.433 0.480 0.527
800 0.505 0.561 0.616
900 0.628 0.684
1000 0.751
Length L [mm]
Height H [mm]
100 150 200 250 300 350 400 450 500 600 700 800 900 1000
100 0.003 0.005 0.007 0.009 0.011 0.013 0.015 0.017 0.019 0.024 0.026 0.032 0.035 0.038
150 0.008 0.012 0.014 0.017 0.021 0.024 0.027 0.031 0.039 0.043 0.520 0.058 0.063
200 0.017 0.021 0.026 0.031 0.035 0.040 0.046 0.057 0.063 0.076 0.084 0.092
250 0.026 0.032 0.038 0.044 0.050 0.057 0.071 0.078 0.094 0.104 0.114
Perforated sheet
300 0.041 0.049 0.056 0.063 0.071 0.088 0.101 0.118 0.131 0.143
350 0.059 0.066 0.074 0.083 0.104 0.119 0.139 0.154 0.169
400 0.076 0.085 0.095 0.120 0.137 0.160 0.177 0.194
450 0.096 0.109 0.135 0.149 0.180 0.198 0.216
500 0.123 0.138 0.153 0.170 0.204 0.246
600 0.154 0.171 0.190 0.228 0.274
700 0.189 0.210 0.253 0.304
800 0.233 0.281 0.338
900 0.338 0.407
1000 0.489
Designation:
ΔP – pressure loss [Pa]
LWA – sound power level [dBA]
LWAO – sound power level for air pass 0.1 m2 [dBA]
K – correction factor for sound power level calculation depending on air pass [dBA]
Sap – air pass [m2]
V – rated speed [m/s]
V [m/s]
ΔP f(V) [Pa]
Lwao [dBA]
Order code
LxH
LxH
L - 19 x H - 19
L - 22 x H - 22
L + 26 x H + 26
Series Application
RN • Supply and exhaust ventilation, heating
and air conditioning networks in industrial,
commercial and domestic premises.
Design
• Made of high-quality extruded aluminium shape and
an insert piece of perforated steel or expanded mesh.
Modifications
• Available modifications with an adapter
Supply and exhaust ventilation grille (A) for connection to air ducts.
with fixed vanes
• Available modifications with versatile
fixing (u) for fast mounting.
fixed (45°)
300 0.039 0.047 0.054 0.061 0.067 0.079 0.087 0.099 0.115 0.127
350 0.059 0.066 0.074 0.082 0.096 0.106 0.121 0.140 0.155
1000 0.511
Designation:
ΔP – pressure loss [Pa]
LWA – sound power level [dBA]
LWAO – sound power level for air pass 0.1 m2 [dBA]
– air supply K – correction factor for sound power level calculation depending on air pass [dBA]
– air exhaust Sap – air pass [m2]
V – rated speed [m/s]
V [m/s]
∆Pf (V) [Pа]
L WAO [dBA]
Order code
LxH
Grille fixation:
u – versatile
LxH
L-8xH-8
L + 30 x H + 30
Series Application
RG • Exhaust ventilation, heating and
air conditioning networks in industrial,
commercial and domestic premises.
Design
• Made of high-quality extruded aluminium shape and
an insert piece of perforated steel or expanded mesh.
Modifications
• Available modifications with an adapter
(A) for connection to air ducts.
Length L [mm]
Height H [mm]
100 150 200 250 300 350 400 450 500
100 0.002 0.008 0.014 0.018 0.023 0.027 0.033 0.038 0.044
150 0.005 0.011 0.017 0.021 0.026 0.030 0.036 0.041 0.047
200 0.008 0.018 0.025 0.031 0.040 0.045 0.054 0.062 0.072
250 0.010 0.021 0.032 0.038 0.048 0.055 0.066 0.076 0.043
300 0.013 0.027 0.041 0.051 0.062 0.071 0.084 0.096 0.113
350 0.016 0.031 0.046 0.057 0.073 0.081 0.096 0.11 0.13
400 0.019 0.037 0.055 0.068 0.087 0.100 0.114 0.131 0.155
450 0.022 0.042 0.062 0.077 0.098 0.112 0.132 0.148 0.171
500 0.024 0.047 0.069 0.085 0.109 0.125 0.144 0.166 0.187
Designation:
ΔPp – pressure loss at various vane positions [Pa]
ΔP – pressure loss [Pa]
Kp – correction factor for pressure loss calculation depending on louvre deflection
V [m/s] angle
∆Pf (V) [Pа] LWA – sound power level [dBA]
L WAO [dBA]
LWAO – sound power level for air pass 0.1 m2 [dBA]
K – correction factor for sound power level calculation depending on air pass [dBA]
Sap – air pass [m2]
V – rated speed [m/s]
Order code
LxH
Grille fixation:
u – versatile
Series Application
RGS • Exhaust ventilation, heating and
air conditioning networks in industrial,
commercial and domestic premises.
Design
• Made of high-quality extruded aluminium shape and
an insert piece of perforated steel or expanded mesh.
Modifications
• Available modifications with an adapter
(A) for connection to air ducts.
100 – – – – – – – – – – – 0.045 0.048 0.053 0.058 0.061 0.066 0.07 0.074 0.078 0.08 0.083 0.087
140 – – – – – – – – – – – 0.064 0.068 0.075 0.083 0.086 0.093 0.1 0.106 0.111 0.115 0.119 0.123
180 – – – – – – – – – – – 0.083 0.088 0.097 0.108 0.111 0.12 0.13 0.138 0.144 0.15 0.155 0.159
220 – – – – – – – – – – – 0.102 0.108 0.119 0.133 0.136 0.147 0.16 0.17 0.177 0.185 0.191 0.195
260 – – – – – – – – – – – 0.121 0.128 0.141 0.158 0.161 0.174 0.19 0.202 0.21 0.22 0.227 0.231
300 – – – – – – – – – – – 0.14 0.148 0.163 0.183 0.186 0.201 0.22 0.234 0.243 0.255 0.263 0.267
340 – – – – – – – – – – – 0.159 0.168 0.185 0.208 0.211 0.228 0.25 0.266 0.276 0.29 0.299 0.303
380 – – – – – – – – – – – 0.178 0.188 0.207 0.233 0.236 0.255 0.28 0.298 0.309 0.325 0.335 0.339
420 – – – – – – – – – – – 0.197 0.208 0.229 0.258 0.261 0.282 0.31 0.33 0.342 0.36 0.371 0.375
460 – – – – – – – – – – – 0.216 0.228 0.251 0.283 0.286 0.309 0.34 0.362 0.375 0.395 0.407 0.411
500 – – – – – – – – – – – 0.235 0.248 0.273 0.308 0.311 0.336 0.37 0.394 0.408 0.43 0.443 0.447
540 0.024 0.04 0.078 0.104 0.118 0.1 0.125 0.14 0.145 0.172 0.231 0.254 0.268 0.295 0.333 0.336 0.363 0.4 0.426 0.441 0.465 0.479 0.483
580 0.026 0.043 0.084 0.112 0.127 0.107 0.134 0.15 0.155 0.184 0.248 0.273 0.288 0.317 0.358 0.361 0.39 0.43 0.458 0.474 0.5 0.515 0.519
620 0.028 0.046 0.09 0.12 0.136 0.114 0.143 0.16 0.165 0.196 0.265 0.292 0.308 0.339 0.383 0.386 0.417 0.46 0.49 0.507 0.535 0.551 0.555
660 0.03 0.049 0.096 0.128 0.145 0.121 0.152 0.17 0.175 0.208 0.282 0.311 0.328 0.361 0.408 0.411 0.444 0.49 0.522 0.54 0.57 0.587 0.591
700 0.032 0.052 0.102 0.136 0.154 0.128 0.161 0.18 0.185 0.22 0.299 0.33 0.348 0.383 0.433 0.436 0.471 0.52 0.554 0.573 0.605 0.623 0.627
740 0.034 0.055 0.108 0.144 0.163 0.135 0.17 0.19 0.195 0.232 0.316 0.349 0.368 0.405 0.458 0.461 0.498 0.55 0.586 0.606 0.64 0.659 0.663
780 0.036 0.058 0.114 0.152 0.172 0.142 0.179 0.2 0.205 0.244 0.333 0.368 0.388 0.427 0.483 0.486 0.525 0.58 0.618 0.639 0.675 0.695 0.699
820 0.038 0.061 0.12 0.16 0.181 0.149 0.188 0.21 0.215 0.256 0.35 0.387 0.408 0.449 0.508 0.511 0.552 0.61 0.65 0.672 0.71 0.731 0.735
860 0.04 0.064 0.126 0.168 0.19 0.156 0.197 0.22 0.225 0.268 0.367 0.406 0.428 0.471 0.533 0.536 0.579 0.64 0.682 0.705 0.745 0.767 0.771
900 0.042 0.067 0.132 0.176 0.199 0.163 0.206 0.23 0.235 0.28 0.384 0.425 0.448 0.493 0.558 0.561 0.606 0.67 0.714 0.738 0.78 0.803 0.807
940 0.044 0.07 0.138 0.184 0.208 0.17 0.215 0.24 0.245 0.292 0.401 0.444 0.468 0.515 0.583 0.586 0.633 0.7 0.746 0.771 0.815 0.839 0.843
980 0.046 0.073 0.144 0.192 0.217 0.177 0.224 0.25 0.255 0.304 0.418 0.463 0.488 0.537 0.608 0.611 0.66 0.73 0.778 0.804 0.85 0.875 0.879
Designation:
ΔPp – pressure loss at various vane positions [Pa]
ΔP – pressure loss [Pa]
Kp – correction factor for pressure loss calculation depending on louvre deflection
V, [m/s] angle
Pf [V], Pa
LWA – sound power level [dBA]
LWAO, dBA
LWAO – sound power level for air pass 0.1 m2 [dBA]
K – correction factor for sound power level calculation depending on air pass [dBA]
Sap – air pass [m2]
V – rated speed [m/s]
Order code
LxH
Grille fixation:
u – versatile
p – spring
Series Application
GRM • Exhaust ventilation, heating and
air conditioning networks in industrial,
commercial and domestic premises.
Design
• Made of high-quality metal
shape with polymer coating
Modifications
• Available modifications with an adapter
(A) for connection to air ducts.
Designation:
ΔPp – pressure loss at various vane positions [Pa]
ΔP – pressure loss [Pa]
Kp – correction factor for pressure loss calculation depending on louvre deflection
angle
V [m/s]
∆Pf (V) [Pа] LWA – sound power level [dBA]
LWAO [dB(А)]
LWAO – sound power level for air pass 0.1 m2 [dBA]
K – correction factor for sound power level calculation depending on air pass [dBA]
Sap – air pass [m2]
V – rated speed [m/s]
Order code
L
Grille fixation:
u – versatile
p – springs
L2 e e
L2
Series Application
DVK • Supply and exhaust ventilation, heating
and air conditioning networks in industrial,
commercial and domestic premises.
Design
• The base made of high-quality polymer
coated steel, the plastic inserts.
Modifications
• Suspended ceiling mounting.
Swirl diffusers
DVK1 DVK3
DVK2
DVK4
Design
• The base made of high-quality polymer
coated steel, the plastic inserts.
Modifications
• Suspended ceiling mounting.
Swirl diffusers
DVP2 DVP3
DVP1
DVP4
Adapter Application
A DP • For connection of the square ceiling
diffusers DP to round air ducts.
Design
• Made of galvanized steel.
ØD
I
I
Connection to a duct
L x H: nominal size of the DP diffuser
b: horizontal connection
v: vertical connection
Design
• Made of galvanised steel.
• Equipped with a sealing ring for tight connection to
air ducts.
• One modification: vertical connection to the air duct.
ØD
Mating part
Package size
A: disk valve
Default – header bag
V: domestic fan
Thermal package – (t/p)
Sealed bag – (s/b)
Unsealed bag – (ns/b)
Designation example
Adapter Application
A DVK/DVP • For connection of the square ceiling
diffusers DVP and DVK to round air ducts.
Design
• Made of galvanized steel.
Overall dimensions and mounting dimensions of the adapter for ceiling diffusers
Order code (grille size, mm) a [mm] b [mm] ØD [mm] K [mm] Weight [kg]
Ab DVP/DVK 295x295/125 292.6 292.6 125 347 1.42
Av DVP/DVK 295 x295/125 292.6 292.6 125 305.5 1.88
Ab DVP/DVK 295x295/140 292.6 292.6 140 347 1.44
Av DVP/DVK 295 x295/140 292.6 292.6 140 305.5 1.88
Ab DVP/DVK 305x305/125 302.6 302.6 125 357 1.49
Av DVP/DVK 305x305/125 302.6 302.6 125 305.5 1.96
Ab DVP/DVK 305x305/140 302.6 302.6 140 357 1.51
Av DVP/DVK 305x305/140 302.6 302.6 140 305.5 1.96
Ab DVP/DVK 395x395/160 392.6 392.6 160 447 2.46
Av DVP/DVK 395x395/160 392.6 392.6 160 305.5 2.69
Ab DVP/DVK 395x395/200 392.6 392.6 200 447 2.52
Av DVP/DVK 395x395/200 392.6 392.6 200 305.5 2.69
Ab DVP/DVK 445x445/160 442.6 442.6 160 497 2.9 a
Av DVP/DVK 445x445/160 442.6 442.6 160 305.5 3.1
Ab DVP/DVK 445x445/200 442.6 442.6 200 497 2.9
Av DVP/DVK 445x445/200 442.6 442.6 200 305.5 3.1
Ab DVP/DVK 495x495/200 492.6 492.6 200 547 3.94
Av DVP/DVK 495x495/200 492.6 492.6 200 305.5 3.59
Ab DVP/DVK 495x495/250 492.6 492.6 250 547 4
Av DVP/DVK 495x495/250 492.6 492.6 250 305.5 3.55
Ab DVP/DVK 595x595/250 592.6 592.6 250 647 5.44
Ab DVP/DVK 595x595/200 592.6 592.6 200 647 5.51
Av DVP/DVK 595x595/250 592.6 592.6 250 305.5 4.55
Ab DVP/DVK 595x595/315 592.6 592.6 315 647 5.55
Av DVP/DVK 595x595/315 592.6 592.6 315 305.5 4.47
Ab DVP/DVK 620x620/250 617.6 617.6 250 672 5.77
Av DVP/DVK 620x620/250 617.6 617.6 250 305.5 4.81 a
Ab DVP/DVK 620x620/315 617.6 617.6 315 672 5.89
Av DVP/DVK 620x620/315 617.6 617.6 315 305.5 4.73
Ab DVP/DVK 695x695/250 692.6 692.6 250 747 6.54
Av DVP/DVK 695x695/250 692.6 692.6 250 305.5 5.64 a
Ab DVP/DVK 695x695/315 692.6 692.6 315 747 6.63
Av DVP/DVK 695x695/315 692.6 692.6 315 305.5 5.56
Ab DVP/DVK 795x795/250 792.6 792.6 250 847 7.98
Av DVP/DVK 795x795/250 792.6 792.6 250 305.5 6.83
Ab DVP/DVK 795x795/315 792.6 792.6 315 847 8.13
Av DVP/DVK 795x795/315 792.6 792.6 315 305.5 6.75
Connection to a duct
Characteristic dimension (1 figure for round and 2
b – horizontal connection
figures for rectangular and square) [mm]
v – vertical connection
100x100 – adapter is designed for specified type of grilles
with characteristic dimension of 100x100 mm
Type of the connected unit 150 – adapter is designed for specified grille or diffuser
The adapter can be used for the following type with characteristic diameter of 150 mm
unit types:
DVP
DVK
Adapter Application
• For connection of the DP, ORH, ORV, ONH, ONV,
ORK, ONL, ONS ventilation grilles with round air ducts.
Design
• Made of galvanized steel.
Order code (grille size [mm]) L [mm] H [mm] ØD [mm] K [mm] Weight [kg]
A (100x100) 86.4 96.4 0.053
A (100x150) 86.4 146.4 0.081
A (100x200) 86.4 196.4 0.108
A (100x250) 86.4 246.4 0.136
A (100x300) 86.4 296.4 80 0.164
A (100x350) 86.4 346.4 0.191
A (100x400) 86.4 396.4 0.219
A (100x450) 86.4 446.4 0.246
A (100x500) 86.4 496.4 0.274
A (150x150) 136.4 146.4 0.128
A (150x200) 136.4 196.4 0.171
A (150x250) 136.4 246.4 0.215
A (150x300) 136.4 296.4 0.258
A (150x350) 136.4 346.4 125 0.302
A (150x400) 136.4 396.4 0.345
A (150x450) 136.4 446.4 0.389
A (150x500) 136.4 496.4 0.432
A (150x600) 136.4 596.4 0.519
A (200x200) 186.4 196.4 0.234
100
A (200x250) 186.4 246.4 0.293
A (200x300) 186.4 296.4 0.353
A (200x350) 186.4 346.4 0.412
150
A (200x400) 186.4 396.4 0.472
A (200x450) 186.4 446.4 0.531
A (200x500) 186.4 496.4 0.591
A (200x600) 186.4 596.4 0.710
A (250x250) 236.4 246.4 0.372
A (250x300) 236.4 296.4 0.447 H ØD
A (250x350) 236.4 346.4 0.523
A (250x400) 236.4 396.4 0.598
A (250x450) 236.4 446.4 0.674
A (250x500) 236.4 496.4 0.749
200
A (300x300) 236.4 296.4 0.542
A (300x350) 236.4 346.4 0.634
A (300x400) 236.4 396.4 0.725
L
A (300x450) 236.4 446.4 0.816 K
A (300x500) 236.4 496.4 0.908
A (300x600) 236.4 596.4 1.091
A (350x350) 336.4 346.4 0.744
A (350x400) 336.4 396.4 0.852
315
A (350x450) 336.4 446.4 0.959
A (350x500) 336.4 496.4 1.066
A (400x400) 386.4 396.4 0.978
150
A (400x450) 386.4 446.4 350 1.102
A (400x500) 386.4 496.4 1.225
A (450x450) 436.4 446.4 1.244
A (450x500) 436.4 496.4 400 1.383
A (500x500) 486.4 496.4 1.542
Design
• Made of galvanized steel. The aluminium
rotating vanes are turned due to plastic gears.
Standard fixing
Fixing with a mounting pair (not included into the delivery set)
Features:
• mounting pair: versatile screw 3.5x35 mm; nylon dowel 6x40 mm;
• used for grille fixation into concrete or brick walls;
• the screw head has the grille colour;
• cross-shaped slot.
Versatile fixing
Features:
• versatile lock enables mounting into walls and ceilings
• easy mounting with a screw-driver
• concealed fixing.
Spring fixation
Features:
• mounting into walls (no ceiling mounting);