0% found this document useful (0 votes)
122 views461 pages

Energy-Saving Ventilation Catalogue

The document appears to be a catalogue for VENTS ventilation products. It includes sections on various types of fans such as intelligent fans, low-noise axial fans, axial inline fans, axial wall-mounted fans, and more. Product names and page numbers are listed on each page. The catalogue aims to bring fresh air and comfortable microclimate to homes.

Uploaded by

Charme Tibanu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
122 views461 pages

Energy-Saving Ventilation Catalogue

The document appears to be a catalogue for VENTS ventilation products. It includes sections on various types of fans such as intelligent fans, low-noise axial fans, axial inline fans, axial wall-mounted fans, and more. Product names and page numbers are listed on each page. The catalogue aims to bring fresh air and comfortable microclimate to homes.

Uploaded by

Charme Tibanu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 461

Air handling units Energy saving ventilation

AirVENTS Geothermal systems


(Catalogue no. 3) GEO VENTS
(Catalogue no. 4)
Energy saving air handling units
with air flow up to 40 000 m3/h, Energy saving system
for use in large residential, GEO VENTS with use of the earth’s
industrial and commercial objects. surface layers heat.
High ventilation system
energy efficiency and low
operating costs.

Domestic fans VENTS VN


(Catalogue no. 7) Mono-pipe exhaust
ventilation
Domestic fans with air flow (Catalogue no. 8)
up to 365 m3/h with extra functions:
timer, humidity sensor,
Exhaust ventilation in houses
motion sensor, etc.
with mono-pipe ventilation
Applied for premises up to 30 m2.
system based on VENTS VN fans.

Energy saving ventilation. Single VENTS presentation


room energy recovery ventilators catalogue
MICRA. (Catalogue no.12)
(Catalogue no.11)
VENTS mission is to bring fresh air to
MICRA single room ventilators with en- your house and surround you with the
ergy regeneration for efficient ventilation world of comfortable microclimate.
and lowest investments in ready-built and
brand new premises.

Round and flat PVC ducting Energy saving ventilation.


(Catalogue no. 15) Single room energy
recovery ventilators
Flat and round PVC ducts TwinFresh.
PLASTIVENT for ventilation of
residential, office and commercial
(Catalogue no.16)
premises and connection of exhaust
ventilation equipment Single room reverse ventilators with
(kitchen extractors, hoods, energy regeneration TwinFresh for
exhaust boxes, etc). efficient ventilation and lowest invest-
Wide product range of fittings. ments in ready-built and brand new
premises.

2020
4 VENTS. Domestic ventilation. Catalogue №6 | 02-2020
CONTENT

About VENTS............................................................................................................................... 20-21

Ventilation in our life................................................................................................................ 22-25

Domestic fans............................................................................................................................. 28-171

Electrical accessories................................................................................................................ 172-189

Air distribution units................................................................................................................. 190-304

Flexible air ducts for ventilation and air conditioning


ALUVENT, POLYVENT, ISOVENT, THERMOVENT............................................................. 306-355

Flat and round PVC ductworks PLASTIVENT..................................................................... 356-387

Access doors for accessing concealed equipment and utility lines.......................... 388-400

Plastic HVAC grilles PROFIPLAST........................................................................................... 402-417

Metal grilles for HVAC....................................................................................................................... 418-460

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 5


INTELLECTUAL FANS

Intellectual fan page Intellectual fan page


iFan 32 iFan Wi-Fi 34
iFan Move iFan Move Wi-Fi

LOW-NOISE AND ENERGY-SAVING AXIAL FANS

Low-noise and energy-saving page Low-noise and energy-saving axial page


axial fans 38 fans 40
VENTS Quiet VENTS Quiet DC

Low-noise and energy-saving page Low-noise and energy-saving axial page


axial fans 42 fans 44
VENTS Quiet-Style VENTS Quiet-S

Low-noise and energy-saving page Low-noise and energy-saving axial page


axial fans 46 fans 48
VENTS Quiet-Disc VENTS Quiet Duo

Low-noise and energy-saving page Low-noise and energy-saving axial page


axial fans 50 fans 52
VENTS Quiet-dMEV DC VENTS Silenta-M

Low-noise and energy-saving Low-noise and energy-saving axial


axial fans page fans page
VENTS Silenta-S 54 VENTS Style 56

Low-noise and energy-saving Axial decorative fans page


axial fans page VENTS Solid 60
VENTS Style DUO 58

Axial decorative fans page


Axial decorative fans page
VENTS Wave 62 VENTS Flip 64

Axial decorative fans page


Axial decorative fans page
VENTS MF 66 VENTS MF Duo 68

Axial decorative fans page


Axial decorative fans page
VENTS Casto 70 VENTS Casto Duo 72

6 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


AXIAL INLINE FANS

page Axial inline fans


Axial inline fans page
76 VENTS VKO
VENTS Quietline 80
VENTS VKOk

Axial inline fans


page
VENTS VKO1
82
VENTS VKO1k

AXIAL WALL- AND CEILING-MOUNTED FANS

Axial fans page Axial fans page


VENTS M 86 VENTS M3 88

Axial fans page Axial fans page


VENTS M1 90 VENTS MA 92

Axial reverse fans Axial fans page


page
VENTS MA reverse VENTS X1 96
94

Axial fans page Axial fans page


VENTS Simple 98 VENTS F 100

Axial fans page Axial fans page


VENTS F1 102 VENTS K 104

Axial fans page Axial fans page


VENTS K1 106 VENTS PF 108

Axial fans page Axial fans page


VENTS PF1 110 VENTS S 112

Axial fans page Axial fans page


VENTS D 114 VENTS IFK 116

Axial fans page Axial fans page


VENTS IFT 117 VENTS IFP 118

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 7


AXIAL DECORATIVE FANS

Axial decorative fans page


Axial decorative fans page
VENTS LD 122 VENTS LD Auto 124

Axial decorative fans page


Axial decorative fans page
VENTS LD light 126 VENTS LD Fresh time 128

Axial decorative fans page


Axial decorative fans page
VENTS Modern 130 VENTS Modern Auto 132

Axial decorative fans page


Axial decorative fans page
VENTS Domino 134 VENTS Z 136

Axial decorative fans page


Axial decorative fans page
VENTS Z star 138 VENTS Vitro VENTS Vitro star 140

Axial decorative fans


Axial decorative fans
VENTS X page page
144 VENTS Lumis 148
VENTS X star

AXIAL WINDOW FANS

Axial window fans page


Axial window reverse fans page
VENTS MAO1 152 VENTS MAO1 reverse 154
VENTS MAO2

Axial window fans


Axial window fans page
VENTS VV page
VENTS M1OK2 156 158
Axial window reverse fans
VENTS VVR

CENTRIFUGAL FANS

Centrifugal single speed fans page


Centrifugal three speed fans page
VENTS CF 162 VENTS CF3 164

ACCESSORIES FOR DOMESTIC FANS

Back valve page


Window flange page
KO series 166 FO Series 167

8 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


ELECTRICAL ACCESSORIES

Thyristor controllers
Fan control unit
page SRS-1, RS-1-300, page
BU-1-60 175
174 RS-1-400, RS-…N (V)

Autotransformer controller page


Speed switches page
RSA 180 SP3-1, P2, P3, P5 182

Temperature regulators page


Transformers page
RT, RTS, RTSD 185 TRF 188

PLASTIC VENTILATION GRILLES

Supply and exhaust grilles page Supply and exhaust grilles page
MV 100 Series 194 MV 101 Series 196

Supply and exhaust grilles page Supply and exhaust grilles page
MV 120 Series 198 MV 121 Series 200

Supply and exhaust grilles page Supply and exhaust grilles page
MV 125, MV 125-1 Series 202 MV 126, MV 126-1 Series 204

Supply and exhaust grilles page Supply and exhaust grilles page
MV 150 V Series 206 MV 151 V Series 207

Supply and exhaust grilles page Supply and exhaust grilles page
MV 150, MV 150-1 Series 208 MV 160 Series 210

Supply and exhaust grilles page Supply and exhaust grilles page
MV 170 Series 211 MV 250, MV 250-1 Series 212

Supply and exhaust grilles


Supply and exhaust grilles page
Single-element MV Series page
MV 80-1 Series 215 (from MV 150x150 to 216
MV 350x350)

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 9


Supply and exhaust round grilles page
Supply and exhaust round grilles page
MV 50 bV, MV 51 bV 217 MV 52 bV Series 218

Supply and exhaust round grilles


Supply and exhaust round grilles page
page MV 100 bV, MV 125 bV,
MV 80 bV, MV 81 bV Series 219 220
MV 150 bV Series

Supply and exhaust hoods


Outer ventilation hood page MV 102, MV 122, page
MVVM 162 Series 221 222
MV 152 Series

Exhaust grilles page Exhaust grilles page


MV 100 J Series 224 MV 120 J, MV 150 VJ Series 225

Exhaust grilles page Exhaust grilles page


MV 160 J Series 226 MV 250 J Series 227

Exhaust grilles
Exhaust grilles page
MV 100 KV, MV 120 KV, page
MV 100 K, MV 125 K Series 228 229
MV 125 KV Series

ASA PLASTIC VENTILATION GRILLES

Supply and exhaust grilles page Supply and exhaust grilles page
MV 100 V ASA series 232 MV 120 ASA series 233

Supply and exhaust grilles


Supply and exhaust grilles page
MV 250 ASA series, page
MV 150 V ASA series 234 235
MV 250-1 ASA series

Supply and exhaust grilles Supply and exhaust ventilation


MV 100 bV ASA, page hoods page
MV 125 bV ASA, 236 MV 102 ASA, MV 122 ASA, 237
MV 150 bV ASA series MV 152 ASA series

Exhaust grilles
Exhaust grilles page
MV 120 J ASA, page
MV 100 J ASA series 238 239
MV 150 VJ ASA series

Exhaust grilles page


MV 250 J ASA series 240

10 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


DOOR PLASTIC GRILLES

Supply and exhaust Supply and exhaust


page
door grille door grille page
MV 350 Series 244 MV 350/2 Series 245

Supply and exhaust Supply and exhaust


page
door grille door grille page
MV 450 Series 246 MV 450/2 Series 247

Supply and exhaust page


Supply and exhaust
door grille 248 door grille page
MV 380 Series MV 380/2 Series 249

Supply and exhaust page


Supply and exhaust
door grille 250 door grille page
MV 430/2 Series MV 440/2 Series 251

SUPPLY AND EXHAUST AIR DISK VALVES


Supply and exhaust plastic air page
Supply and exhaust plastic
disk valves 254 air disk valves page
A…VR Series A…VRF Series 256

Supply plastic air disk valves page Supply plastic air disk valves page
A…PR Series 258 A…PRF Series 260

Supply and exhaust metal


Supply metal air disk valves page page
262 air disk valves 264
AM…PRF Series
AM…VRF Series

Supply and exhaust


Supply and exhaust plastic diffusers page
metal air disk valves page
267
266 MV…PF Series
AM...VRF N Series

Supply and exhaust plastic Supply and exhaust plastic diffusers


diffusers with light page with light page
FL 100 Series 268 FL2-100 Series 270

SUPPLY AND EXHAUST METAL GRILLES


Supply and exhaust
Supply and exhaust
single-row metal grilles page
276 multiple-row metal grilles page
MVM Series 278
MVMP Series
MVMP Series

Supply and exhaust slot Supply and exhaust single-row


page
metal grilles metal edge-raised grilles page
MVMP Series 280 MVMPO Series 281

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 11


Supply and exhaust
Supply and exhaust metal
multiple-row metal page
slot edge-raised grilles page
edge-raised grilles 282 284
MVMPO Series
MVMPO Series

Supply and exhaust


Supply and exhaust
page regulated slot metal grilles
metal regulated grilles page
285 MVMPO...Rr Series 286
MVMPO...R Series
MVMPO...R Series

Supply and exhaust page


Supply and exhaust
metal door grilles 287 metal door grilles page
MVM Series MVMP Series 288

Supply and exhaust page


Supply and exhaust page
metal door grilles 289 metal grille 290
MVMA Series MVM...bV A Series

Supply and exhaust page


Supply and exhaust page
metal grille 291 metal grille 292
MVM...bV N Series MVM...b N Series

Supply and exhaust page Exhaust gravity metal grille page


metal hoods 293 295
MVM...VJ N Series
MVM... bVs N / bV N Series

Supply and exhaust


Exhaust metal hoods page page
296 metal grille 297
MVM...V N Series
MVM...bVL A Series

Supply and exhaust Supply and exhaust


page page
metal grille metal grille
MVM...VR N Series 298 MVMP...R N / R A Series 299

Supply and exhaust Supply and exhaust


page page
metal grille metal grille
MVMO1...b Series 301 MVMO...bV Series 302

Supply and exhaust


page
metal grille
MVMO…bS K1 304

12 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


FLEXIBLE AIR DUCTS FOR VENTILATION AND AIR CONDITIONING

Aluminium foil Aluminium foil


page
non-insulated air ducts insulated air ducts page
Polyvent 605 series 316 Isovent 605 series 317

metalized foil Metalized foil


page
non-insulated air ducts insulated air ducts page
Polyvent N series 318 Isovent N 319

Polyvinylchloride [65 μm] Polyvinylchloride [110 μm]


page
non-insulated air ducts non-insulated air ducts page
Polyvent 660 series 320 Polyvent 661 series 321

Polyvinylchloride [250 μm] Polyvinylchloride [700 μm]


page
non-insulated air ducts page non-insulated air ducts
Polyvent 606 series 322 Polyvent 607 series 323

Polyether fiber covered with Polyether fiber covered with


polyvinylchloride [250 μm] page
polyvinylchloride [250 μm] page
non-insulated air ducts 324 non-insulated air ducts 325
Polyvent 600 series Polyvent 601 series

Custom-designed polyurethane Specially designed polyurethane


[250 μm] page [450 μm] page
non-insulated air ducts 326 non-insulated air ducts 327
Polyvent 620 series Polyvent 621 series

Aluminium foil and PVC Polyethylene [75 μm / 150 μm]


page
non-insulated air ducts non-insulated air ducts page
Polyvent 665 Comby series 328 Polyvent 615 series 329

AIR DUCTS FOR VENTILATION, HEATING AND AIR CONDITIONING

Aluminium foil Galvanized and stainless steel non-


page
non-insulated air ducts insulated air ducts page
Aluvent series 334 Thermovent series 335

Stainless steel Stainless steel


page
non-insulated air ducts non-insulated air ducts page
Thermovent Aero series 336 Thermovent Flex series 337

Stainless steel
page
non-insulated air ducts
Thermovent Aero Flex series 338

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 13


FITTINGS

Polymer coated Galvanized steel


page page
Cross Tee Cross Tee
KM 342 KM…Zn Series 342

Polymer coated Galvanized steel


page
T-joint T-joint page
TM Series 343 TM…Zn Series 343

Polymer coated Galvanized steel


page
Y-shaped T-joint Y-shaped T-joint page
TMY Series 344 TMY…Zn Series 344

Polymer coated Galvanized steel


page
Reducer Reducer page
RM Series 345 RM…Zn Series 345

Polymer coated Galvanized steel


page
Flange Flange page
FM Series 346 FM…Zn Series 346

Polymer coated Galvanized steel


page
Reducer Reducer page
FMK Series 347 FMK…Zn Series 347

Polymer coated Plastic


page
Flange Flange page
F Series 348 FK Series 348

Polymer coated Galvanized steel


page
Reducer Reducer page
PM series 349 PM…Zn series 349

Mounting kit page page


Clamps
NM Isovent Series 350 352

Bend holder (bracket) page


page Mounting tapes
PDV series 354 355

14 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


FLAT AND ROUND PVC DUCTWORKS

page
Round duct Round telescopic duct page
366 367

page
Round flexible duct connector 90° bend for round ducts page
367 367

page
45° bend for round ducts page T-joint for round ducts
368 368

page
Wall plate for round ducts page Round duct connector
368 369

Connector with backdraft


Connector with backdraft page
page damper and wall plate for
damper for round ducts 369 370
round ducts

Connector with plate for page


page Reducer
round ducts 370 371

page
Reducer page Step round reducer
372 372

page
Eccentric reducer Round to flat connector page
373 373

page
Round flexible duct connector 374 Holder for round ducts page
374

page
Flat duct 375 Flat duct connector page
376

Flat duct connector page


376 Flexible flat duct connector page
with damper 377

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 15


page Air duct connector with page
Air duct connector with a plate 377 378
a plate and a back valve

Vertical 90° bend for page Horizontal 90° bend for page
flat ducts 378 flat ducts 379

Versatile flat angular page


379 T-joint for flat ducts page
connector 380

page 90° connecting bend for


Flat duct holder 308
page
flat and round ducts 381

T-joint for flat and page


381 Reducer for flat ducts page
round ducts 382

page
Wall plate for flat ducts 382 End grille page
382

End grille with air pass page Reducer for flat and page
regulation 383 round ducts 383

page Round to flat connector


Wall plate with flange 384
page
(symmetric) 385

ROUND AND FLAT FOLDING PVC DUCT SYSTEM

page
Round duct 387 Flat duct page
387

ACCESS DOORS FOR ACCESSING CONCEALED EQUIPMENT AND UTILITY LINES


Plastic page
Plastic
access doors 389 access doors page
D (D2) series DPV series 390

Plastic (with lock) Plastic (double sided hinges) page


access doors page access doors 392
DZ series 391 DD series

16 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Metal Metal (with lock) page
access doors page access doors 394
DM series 393 DMZ series

Metal Metal page


access doors page access doors 396
DMR series 395 DMV series

Recessed for ceramic tiles Recessed for ceramic tiles page


access doors page access doors 398
DKP series 397 DKM series

Designed for plasterboard


Access metal doors for
wall or ceiling application page ceiling mounting page
access doors 399 400
DPM series
DG series

PLASTIC HVAC GRILLES

Supply and exhaust grilles page Supply and exhaust grilles page
NHN (NUN) series 404 NVN (NUN) series 404

Supply and exhaust grilles page Supply and exhaust grilles page
GR series 406 RD series 410

Supply and exhaust grilles page


Supply and exhaust grilles page
ND series 412 NK-3 series 414

Supply and exhaust grilles page


NK-4 series 416

METAL GRILLES FOR HVAC

Single-row unregulated
Single-row unregulated grilles page
linear grilles page
ONG, ONV 420 422
ONL

Single-row unregulated
Single-row unregulated grilles page
page sectional grilles
ONF, ONFS 424 424
ONK

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 17


Single-row regulated
Single-row regulated grilles page sectional grilles page
ORG, ORV 428 430
ORK

Double-row regulated grilles page Ceiling diffusers page


DR 432 DP 434

Ceiling diffusers page Slit diffusers page


DPp 436 DS 438

Supply and exhaust


Perforated grilles page
ventilation grille page
RP 440 442
RN

Fravity grilles page Gravity grilles page


RG 444 RGS 446

Gravity grilles page Swirl diffusers page


GRM 448 DVK 450

Swirl diffusers page page


Adapters
DVP 451 452

page
Air flow regulator
459

18 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


VENTS. Domestic ventilation. Catalogue №6 | 02-2020 19
WELCOME TO THE WORLD OF VENTS!
Being the world's ventilation leader VENTS brand you can be confident that you have made
offers a wide range of cutting-edge ventilation the right choice. Thanks to a comprehensive range
equipment to satisfy most demanding customers. of ventilation equipment for home, commercial
Since the inception, the company's products and industrial application you can always find
have become popular in more than 100 countries the necessary equipment and components to suit
worldwide while the VENTS brand has earned your needs. The climatic engineering and design
a solid reputation for quality, reliability and solutions department is tasked with developing
innovation. Every tenth domestic fan in the world bespoke ventilation and air conditioning systems
rolled off the assembly line of the VENTS factory. for even the most challenging projects.
Every time you buy a product carrying the VENTS

Technology of the future


The company's product range The VENTS factory is not just about state-of-the-
includes over 50.000 items
art production lines equipped with processing
machines from the leading global suppliers. Today
Over the years the company has this is a full-on research and development facility
produced 100 million fans spreading across 150.000 square metres of territory
which includes a climatic equipment research and
development centre and a comprehensive suite of
The production facilities spread
across 150.000 square meters of state-of-the-art laboratories.
territory The full-time staff of more than 200 engineers
are continuously seeking to improve the VENTS
products. The company utilises cutting-edge
The company employs more than
metal and polymer processing technology
3.500 professionals involved in the
entire life cycle of creating ventila- manufacturing 99 % of its products in-house.
tion equipment – from concept to We are the only company in the industry
high-tech product which develops and builds 85 % of its ventilation
equipment components including electric motors,
heat exchangers as well as control and automation
Among other assets the facilities
include the climatic equipment equipment.
research and development centre
and a suite of state-of-the-art labo-
ratories manned by 200 engineers
Getting better every day
The company utilises the latest The world of today is nothing but stable or
metal and polymer processing permanent. Each day the market comes up with
technology new expectations with regards to ventilation
equipment quality and performance. Therefore,
VENTS places a strong emphasis on constant
99 % of our products are made
in-house development and improvement.
To this end the company has adopted a
policy which includes continuous upgrades to
We are the only company in the its process equipment fleet, implementing the
industry which develops and builds
latest in manufacturing technology, and holding
85 % of its ventilation equipment
components. regular training workshops for its staff. Not only
does this help us keep abreast with the times –
these efforts help us to exceed our customers'
expectations.

20 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Uncompromising quality
VENTS maintains a stringent quality control standard for quality management systems of
system to make sure that its products always organizations and enterprises. The company Following the
customer's lead
meet most demanding international standards as operates in accordance with all the applicable
confirmed by numerous certificates issued by the environmental standards and continuously
world's largest and most reputable organisations implements new technology in order to ensure
for quality control.The VENTS production process is compliance with the latest environmental VENTS uses its extensive research
certified according to ISO 9001:2015 international regulations. and technical capabilities to develop
bespoke ventilation products and
solutions for its customers from
around the world.
Energy efficiency and energy saving
Energy resources are finite and costly. This is more competitive products. The outstanding Our products have earned a reputa-
why energy-saving is among the company's top energy efficiency and low power consumption tion for reliability being used in polar
priorities. We pay a special attention to using heat of our ventilation equipment are achieved by regions and in the Sahara desert, in
and electricity in the most efficient manner which using high-performance EC motors and heat the jungle of South-Eastern Asia and
helps us reduce the environmental footprint exchangers. in the Pamir mountains.
of the manufacturing process and develop
Wherever our customers are they can
always depend on prompt delivery
thanks to our worldwide network of
Human resources: a valuable asset strategically located logistics centres.
Besides maintaining technical leadership and
developing new technology the company also The company's newest arrivals are
values the people that it owes its success to. presented by its engineers at numer-
Today VENTS employs more than 3.500 ous international exhibitions every
professionals involved in the entire life cycle of year.
ventilation equipment creation – from concept to
high-tech product. The company strives to create a
comfortable working environment for its employees
to maximise their performance and encourage
their professional and personal development.

Responsible corporate citizen


Being a responsible corporate citizen VENTS
takes an active part in various academic and
charity initiatives. The company has a long
history of cooperation with a number of
educational establishments extending its
support to talented youth.
The company takes an active part in student
competitions and workshops sharing its wealth Welcome to the world
of practical knowledge and providing access of modern ventilation
to state-of-the-art ventilation equipment. The by VENTS!
company employees participate in a range of
charitable events and sporting competitions on
a regular basis.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 21


VENTILATION IN OUR LIFE

from outside the oxygen content decreases, humidity and dustiness level increase. If ex-
haust ventilation is not provided or it is not effective, polluted air, smells, humidity and
harmful substances are not removed.
Well coordinated operation of supply and exhaust air vents is one more important factor
for properly arrangement of ventilation system. In case of exhaust ventilation only (i.e.
exhaust ventilation in the bathroom) air from outside flows through all possible gaps in
windows, doors and walling. Such non-arranged air supply brings dust ingress, smells and
drafts.
The door grilles installed in the bathrooms, wall or window vents, open windows or win-
dow leaves serve as natural sources of supply ventilation and are used to compensate air
removal. However, forced mechanical ventilation with centralized air supply and distribu-
 What is ventilation? tion is a much better solution.

Ventilation is a complex of actions and facilities used for air exchange arrangement to  Calculation of the required air exchange
provide the specified air condition in the premises and in working places. Engineering recommendations
Ventilation systems maintain admissible meteorological parameters in various premises.
Ventilation system should create the internal atmosphere that meets the specified hy- Effective ventilation depends on fan or ventilation system selection with suitable air flow
gienic standards and technological requirements. that meets your requirements.
Some factors to be considered:
 What is ventilation required for? – Ventilated area volume
– Air exchange by the hour
We are surrounded with air and breathe in and out 20 000 litres of air every day. How much Multiple the ventilated premise volume by air exchange per hour and get the required fan
healthy is the air we breath in? capacity.
There is a range of aspects to determine air quality. Air exchange calculation according to the ventilation rate in the room.
 Oxygen and Carbon Dioxide Concentration in the Air. Oxygen decrease and carbon di- Ventilated air amount is calculated on an individual basis for each premise with respect to
oxide cause stuffiness in the premises. harmful substances content or is determined by test results. If the nature and number of
 Harmful Substances and Dust in the Air. High content of dust, tobacco smoke and harmful impurities (substances) cannot be identified or measured air exchange is calcu-
other substances in the air are harmful for the human organism and can cause various lated with the formula:
lung and skin diseases. L = Varea * Kp (m3/h),
 Odours. Bad smell causes discomfort or irritates nervous system. where: Varea – ventilated area volume [m /h]. Kp – minimum air exchange per hour, see air
3

 Air Humidity. High or low humidity causes discomfort and even may result in acute exchange table.
disease attacks. Air humidity is important also for the internal atmosphere. So, decreased
humidity in winter can cause shrinkage and cracks of wooden doors, window frames, fur- How to calculate ventilated area volume?
niture and high humidity in swimming pools and bathrooms and other humid premises Calculate the total volume of the premise in m3. Use a simple formula:
can cause excessive humidity absorption and swelling.
 Air temperature. A person feels comfortable in a premise with the temperature 21- Length x Width x Height = Volume of the premises m3
23°C. Temperature variation causes the change of «comfort» well-being more or less that
influences a person’s physical and mental activity. A x B x H = V (m3)
 Air Motion. Increased air speed in the premises causes the feeling of draft, and decreased
speed causes air blanketing. Being inside we feel the impact of any of these factors. Example: premise with 5 m length,
3  m width and 2.8 m height. To
 Ventilation system arrangement determine the air volume required
for ventilation of this premises,
Properly arranged ventilation system is the only solution in this situation. It provides fil- calculate the volume of the room:
tered air supply in summer and filtered and warmed supply air in winter as well as extract 5 x 3 x 2.8 = 42 m3. After that
stale air removal from the premises. determine the required fan capacity
Any ventilation system must include synchronous fresh air supply and extract air exhaust using the following tables of recom-
thus ensuring the ideal air balance in the room. In case of poor or insufficient air intake mended ventilation rate.

22 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


 Natural and mechanical ventilation Air exchange rate:

Premise type Air exchange rate


Natural ventilation requires no electric equipment such as fans or motors and is origi-
nated by natural seasonal factors as external and internal air temperature drop, pres-
3 m3/h per 1m2 for
sure level as a function of height, wind loading. But no matter of the season or weather Living room
residential premises
natural ventilation cannot provide full-featured air exchange. Natural ventilation is
Kitchen 6-8
enough to provide minimum air exchange for passive ventilation of periodically oc-

Residential premises
Bathroom 7-9
cupied premises but its capacity is not enough for well balanced air exchange.
Shower room 7-9
Mechanical ventilation devices ensure active air exchange and can operate continu-
WC 8-10
ously or periodically depending on the ventilation need. Unlike natural ventilation,
Domestic laundry 7
mechanical ventilation operates regardless of natural conditions and indoor and out-
door temperature difference. Fan and electric motors are the basic mechanical ventila- Dressing room 1.5
tion components that provide controllable air exchange. So mechanical ventialtion is Store room 1
the best solution. Garage 4-8
Cellar 4-6

Natural ventilation Mechanical ventilation

 Ventilation shaft functionality check


easy assembling and layout in case
of correct equipment and materials
easy and value-priced, provided selection and installation during Make sure of available ventilation pressure in the shaft before mounting a fan inside.
during construction stage construction or finishing works. In Ventilation shafts may be clogged by construction waste or closed because of incorrect
some cases installation after finishing construction alteration of flat(s) above. To check the ventilation pressure in the shaft
works is possible
cover it with a paper sheet. If the ventilation pressure is enough the paper sheet sticks
to the shaft surface. Otherwise you have to contact your house manager to get the
no electric mechanisms and no power requires connection to power mains ventilation shaft duly operable.
supply connection and consumes electric energy
 Provide even ventilation for all the premise
the modern fans reliability is quite
no failure possibility high, however as all mechanical
devices they can break down Air motion in the room depends not only of supply and exhaust ventilation accessories
but on their location.
Fan operation generates low pressure area that attracts fresh air supply through any
weather-dependent efficiency: very provide required ventilation no matter openings and slots. That is why location of supply and exhaust ventilation accessories is
low in summer of season and weather conditions of great importance for ventilation system efficiency. In other words, air supply and air
exhaust vents should be located in such a way as to ensure fresh air motion throughout
all the room space. For large premises it is recommended to install several fans with
low or medium capacity instead of one high-powered fan to observe the total air flow.
higher air exchange rate is effected by
limited ventilation rate regulation
switching the fan to higher speed

significant thermal losses in winter


reducing heating costs in case of use
open windows for ventilation in of heat recovery technology
summer

fans provide required air flow and


excessive air flow or backdraft in case
backdraft dampers provide required
of strong wind pressure
air distribution

filtration, heating or cooling intake air


no air filtration, heating or cooling from outside before supplying it to
the premise

no draughts as ventilation does not


drafts make feel uncomfortable
require open windows

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 23


VENTILATION IN OUR LIFE

 Fan types: dBA Characteristics Sound source


0 no noise
Fans are the mechanical devices that provide air motion along air ducts, direct air supply
5
or air exhaust from the premise. Air motion is effected due to pressure drop between the almost not audible
10 low leaves rustling
fan intake and exhaust.
15 medium leaves rustling
hardly audible
20 human whisper (1 m distance)
 High efficiency at low air resistance
25 human whisper (1 m distance)

Axial fans are the wheels with blades (so called im- low noise whisper, wall clock ticking
30 standard sound level for residential premises
peller) enclosed in cylindrical casings and attached
from 23.00 till 07.00
to the hub at required angle to plane of rotation.
35 low speech
As impeller blades rotate air is trapped between
standard speech
the blades and moved further axially. Air is hardly 40 audible enough standard sound level for residential premises
moved in radial plane of rotation. Normally the axial from 07.00 till 23.00
fan blades are fixed directly to the motor shaft. 45 conventional conversation
Application: air exhaust and air supply through 50 conversation, typing
definitely audible
free openings or vents or in assembly with air ducts mounted up to 30 m horizontally with 55 Standard sound level for class A offices (EN)
low air resistance in the system. 60 office standard sound level
65 loud conversation ( > 1m)
 Solutions for long air ducts noisy
70 several conversations (< 1m)
75 loud conversation (<1 m)
Turbine and scroll casing are the basic components of the centrifugal fan. The centrifugal
80 shouting, operating motorcycle with a silencer
fan impeller is a hollow cylinder with the blades inside that are fixed to the cylinder cir-
85 loud shouting, operating motorcycle with a silencer
cumference with disk plates. The hub is located inside of these plates and is designed for very noisy
90 Loud shouts, moving railway vehicle (7 m)
mounting of the impeller on the shaft. As the impeller rotates air is trapped between its
95 moving subway train (7 m)
blades, gets pressurized and moves in radial direc-
Orchestra, top noise level of the moving subway train,
tion from the center.
thunder
Under centrifugal force air is transported to the 100
Maximum permissible sound pressure for headphones
scroll casing and then to the exhaust pipe. of a personal stereo (EN)
extremely noisy
Application: air exhaust and air supply in ventila- 105 inside the airplane (before 1980s)
tion systems with extended air ductworks and high 110 helicopter
air resistance. 115 sandblaster (1 m)
120 nearly unbearable pneumatic hammer (1 m)
 Fan noise level characteristics
130 pain threshold airplane at start

Noise parameters are shown in the tables that include the following characteristics:
 Noise level LWA, dBA with various frequency band groups, LWA inlet, LWA outlet and
LWA surrounding.
 The total sound power level at 3 m distance.
The frequency band has eight wave groups. Each group has a definite medium
frequency: 63 Hz, 125 Hz, 250 Hz, 500 Hz, 1000 Hz, 2 kHz, 4 kHz and 8 kHz.
Any noise is classified according to frequency bands and the sound energy has various
frequency groups.
The sound produced by the operating fan is spread along the air duct, get partially attenu-
ated inside the unit and penetrates through the grilles inside the premise.
Ventilation system design is based on acoustic calculation which is an integral part of any
ventilation project for any construction object.
The calculation is aimed to define the octave-frequency band in various operating points
and to determine the required sound attenuation level by comparing this spectrum with
the permissible values according to hygienic norms and standards. After selection of the
design and acoustic facilities to be used for noise level reducing the sound pressure levels
are checked for consistence with expected values in the same operating points.

24 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


VENTILATION IN OUR LIFE

 What is IP?

While selecting the equipment and its location it is extremely important to ensure compliance of the protection rating to the operating conditions. Any electrical device must
meet two protection requirements:
safety for the user and operating personnel
protection of the electrical components located in the device against environmental impact.
IP rating refers to dust and moisture protection of the equipment and its electrical safety. Ingress protection rating marked as IP followed by two digits is stated in the technical
documentation and on the equipment casing. F.e. IP20 or IP65. The first digit means protection rating against contact to the electrical parts and contact to foreign objects. The
first digit designations and characteristics are listed in the table 1.
The second digit means water ingress protection rating and its designations and characteristics are listed in the table 2.

Table 1
First digit Protection characteristics Description
x No special protection Open design, no special protection against dust ingress and contact to electrical parts.
1 Protection against large objects Protected against large solid objects up to 50 mm, e.g. accidental contact with hands.
Protection against medium-sized
2 Protected against solid objects up to 12 mm, e.g. fingers contact to electrical parts.
objects
Protected against penetration of solid objects over 2.5 mm (tools and wires). Protection against accidental
3 Protection against small objects
contact to electrical parts with tools or fingers.
Protected against solid objects over 1 mm (small tools and wires). Protection against accidental contact to
4 Protection against sand penetration
electrical parts with tools or fingers.
Very limited dust ingress inside the casing that does not disturb the rated equipment operation. Total
5 Protection against dust accumulation
protection against contact to electrical parts.
6 Total dust ingress protection Total protection against dust penetration.

Table 2
Second digit Protection characteristics Description

x No protection Open design, no water protection


Protection against vertically falling
1 Vertically falling drops of water e.g. condensation cause no harmful effect for the equipment.
drops of water.
Protection against water drops falling
2 Water drops falling at 15° or less cause no harmful effect for the equipment.
at angle
3 Protection against water sprays Water sprays falling at 60° or less cause no harmful effect for the equipment.
Protection against water sprays from
4 Water sprays from all directions cause no harmful effect for the equipment.
all directions
5 Protection against water jets Directed water jets cause no harmful effect for the equipment in the casing.
Protection against flooding
6 Water flooding causes no harmful effect for the equipment in the casing.
of water
Protection against immersion
7 Immersion of the casing in water causes no harmful effect for the equipment inside the casing.
in water
Protection against immersion in Immersion of the equipment in water to some depth causes no harmful effect (protection against pressurized
8
water under pressure water, the pressure value is stated separately).

Certification

CE mark means that the equipment is produced in compliance with Mark of conformity of the goods subject to obligatory certification
the quality and safety standards provided by EU regulations for the in DSTR system as well as technical norms and standards acting in
given product type (marked by manufacturer). Russian Federation. Confirmed by the RosTEST certificates (Moscow).

Mark of conformity to the European Quality Standards and


Electrical Safety issued by Association for Technical Inspection Insulation class: double insulation.
(Technischer Überwachungsverein, Germany).

Mark of conformity to the Ukrainian Quality Standards and electrical


Equipment protection rating (refer to tables 1, 2).
safety issued by UkrTEST.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 25


DOMESTIC FANS OPTIONS

Domestic fans options

Pull cord switch


Fan is switched on and off by a pull cord. The pull length is adjustable.

Timer
On power-off the fan continues operating within the time period set by the timer setting from 2 to 30 minutes.

Humidity sensor
Fan is equipped with an electronic processor with permanent humidity level monitoring function that prevents condensate
generation. The fan switches automatically on as the relative humidity in the premise reaches the preset threshold value
adjustable from 60 to 90 % and continues operating within 2 to 30 minutes according to the timer setting.

Motion sensor
Fan switches automatically on in case of motion detection in the premises and continues operating within the time period from 2
to 30 minutes according to the timer setting. The motion sensitivity area from 1 to 4 m and the detection angle up to 100°.

Ball bearings motor


Fan motors are equipped with ball bearings that ensure long service life rated for 40.000 hrs and reliable operation in case of
ceiling mounting.

Turbo
Fan is equipped with a high-powered electric motor for higher air flow.

Press
Models are equipped with a 5-blade silent operation impeller with improved aerodynamics for higher fan pressure. Such impeller
design allows attaining previously unachievable air flow characteristics for axial fans.

12 V
Fan is equipped with a low-voltage (12 V) electric motor for safe operation in humid areas and spaces with high water ingress
probability (bathrooms, saunas etc.).

Backdraft damper
Fan is equipped with a backdraft damper for air back flow preventing. The backdraft damper is supplied as a standard with all
modifications of M, M1, D, S, M3, X, X1, and LD fans. The damper is also available as a separate equipment for KO 100, KO 125, and
KO 150 models.

26 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


DESIGNATION KEY

Domestic fans designation key

VENTS Flange diameter Series Built-in options Extra Option Motor options
[mm]

100 V – Pull cord Backdraft Ball bearings


switch damper motor (L)
125
150 T – Timer
180 Turbo

230
TH – Humidity
Sensor Press

TP – Motion
12 V
Sensor

Designation key example

Flange
diameter [mm]

TM Series

VENTS 100 M V T H K L Turbo

Pull cord High-powered


switch motor

Timer Ball bearings motor

Humidity Backdraft damper


sensor

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 27


DOMESTIC FANS
for areas up to 30 m2

Axial inline fans


Axial decorative fans Low-noise and Centrifugal fans
energy-saving axial fans

Axial window fans


Axial wall- and
ceiling-mounted fans

VENTS offers a wide range of domestic fans that combine outstanding performance and reliability
with low power consumption and noise levels. These units are the perfect solution for ventilating
bathrooms, kitchens, living quarters and other premises of up to 30 m2.
VENTS fans are available in manifold modifications with various air flow, design and functioning.

28 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Intellectual fans page
30

Low-noise and energy-saving axial fans page


36

Axial inline fans page


74

Axial wall- and ceiling-mounted fans page


84

Axial decorative fans page


120

Axial window fans page


150

Centrifugal fans page


160

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 29


INTELLECTUAL FANS

Intellectual ventilation era!

30 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Intellectual fans
VENTS iFan Series, VENTS iFan Move Series page
Air flow up to 133 m /h
3 32

Intellectual fans
VENTS iFan Wi-Fi, VENTS iFan Move Wi-Fi Series page
Air flow up to 133 m /h
3 34

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 31


INTELLECTUAL FANS

iFan • The motor-impeller block is easy to remove


without special tools which grants easy servicing.
SLEEP – the fan is ready to accept a signal from
the humidity sensor or external switch.
iFan Move SILENT – optimum humidity extraction mode that
Series provides sufficient air flow (up to 83 m3/h) combined
with silent operation.
MAX – excessive humidity extraction mode
with highest speed and maximum air flow (up to
133 m3/h).

TIMER / Control of time / humidity


extraction / switch delay time /
turn-off delay time

• The fan has a ultra-thin casing with its • The fan is equipped with three timers:
thickness only 29 mm without a spigot. Humidity timer – setting of the fan operation for
• The fan is equipped with an integrated on/off total humidity extraction after its stabilization (30,
power slide switch for quick disconnection from 45, 60 min).
power mains. Turn-off timer – the fan continues operation for
5, 15 or 30 minutes after activation of the motion
sensor or the external switch and then reverts to
Motor the previous operation mode.
Intellectual axial fans for exhaust Switch delay timer – adjust the switch delay
ventilation with air flow
• Reliable motor on ball bearings with minimum timer to avoid the fan unnecessary switching if
energy demand up to 3.8 W.
up to 133 m3/h you use your bathroom shortly and frequently.
• The bearings are maintenance-free and are After humidity increases or after signal from the
filled with grease for the motor service life. external switch/motion sensor, the fan switches to
Application • The fan is powered through an integrated higher speed not immediately, but after the timer
pulse power supply unit with a wide power countdown (0, 2 and 5 minutes).
• Innovative exhaust fan with stylish design for supply range from 100 to 240 V and 50 to
new comfort level in shower rooms, bathrooms, 60 Hz. The fan is suitable for application in various
kitchens and other residential premises. countries and has stable operation in versatile SPEED / Fan speed adjustments

• Intellectual integrated control functions let power mains. • The fan has smooth ten step speed
control:
adjust personal settings for the most balanced • The motor is installed on a rubber anti-
microclimate. vibration connector for vibration absorbing and – for SILENT mode: from 40/33 to 83/72 m3/h (Ø
silent fan operation. 125/100 mm);
Design • The motor is equipped with overheating – for MAX mode: from 83/72 to 133/106 m3/h (Ø
protection. 125/100 mm);
• Unique motor design and aerodynamic
impeller profile ensure the minimum noise
level – only 21 dBA whereas the air flow remains 24 HOURS / Permanent ventilation
Modifications and Options
high.
• Permanent low-speed operation
Basic model with intellectual mode ensures continuous minimum
humidity control. air exchange in the room with air flow 40/33 m3/h
Model with intellectual (Ø 125/100 mm). After humidity change the fan
humidity control and is switched to MAX mode (by default) or SILENT
extra motion sensor mode. The fan is switched to SILENT mode after
control. signal from the motion sensor or external switch.

Automatic interval ventilation


Intellectual functions
• Integrated function of automatic
• Multi-functional control panel for control of ventilation switching. Once in 15
intellectual functions. hours the fan is switched on for 2 hours to
• Front panel 3D design and rich colour palette ventilate the premise with air flow 83/72 m3/h
of replaceable decorative panels give zest to the
(Ø 125/100 mm).
most refined interior.
• Due to replaceable spigots the fan is suitable for
mounting with Ø 100 or Ø 125 mm air ducts. MOVE / Motion sensor (for the
model iFan Move)
• The fan is switched to SILENT mode
automatically in case of a signal from the motion
sensor with the reach distance 1-4 m and viewing
angle 100°.
HUMIDITY MODE / Humidity
control adjustments
• The fan is equipped with an
intellectual humidity sensor with three operation
modes:

32 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Decorative front panel colours*

melange silver ruby star topaz violet graphite  black sapphire


* The decorative panels are available separately.

Aerodynamic characteristics Overall dimensions

Dimensions [mm]
Model
ØD B H L L1
iFan
100/125 152 206 57 29
iFan Move

Air flow [m3/h]


B

Technical data

Spigot Max. air Sound Pressure


Air flow, factory Regulation
Model diameter Mode capacity Level at 3 m
settings [m3/h] range [m3/h]
[mm] [m3/h] [dBA]

24 HOURS 33 17 33 -
100 SILENT 72 22 72 33...72
iFan
iFan Move MAX 106 31 82 72...106
24 HOURS 40 17 40 -
125 SILENT 83 21 83 40...83
MAX 133 32 97 83...133

Certificates

The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 33


INTELLIGENT FANS

READY
Series Automatic interval ventilation
Automatic interval ventilation (function is
iFan Wi-Fi only available when the 24 hours mode is
CONTROL
iFan Move Wi-Fi deactivated). This mode allows ventilating the room
every 12 hours for 30 minutes at the set speed.
Silent mode
The fan runs at Silent speed. The speed
can be adjusted in the range from 30 % to
100 % of the fan maximum performance.
Max (Boost Mode)
• The fan has an ultra-thin casing with a thickness
of only 29 mm without a spigot. The fan runs at Max speed. The speed can
be adjusted in the range from 30 % to 100
• The fan is equipped with an integrated on/off
% of the fan maximum performance.
power slide switch for quick disconnection from
power mains. HUMIDITY SENSOR / Humidity con-
trol adjustment
The fan has an integrated intelligent hu-
Motor midity sensor with the following operation modes:
Manual mode allows setting the humidity thresh-
Intellectual axial fan with an integrated • Reliable motor on ball bearings with minimum
old in range from 40 % to 80 %. If this threshold is
Wi-Fi module for exhaust ventilation with energy demand up to 6 W.
exceeded, the fan turns on or switches to higher
air flow up to • The bearings are maintenance-free and are filled speed.
133 m3/h with grease for the whole motor service life.
Auto – intelligent humidity control. This mode pro-
• The fan is powered through an integrated pulse vides for humidity threshold change and fan speed
power supply unit with a wide power supply range selection in automatic mode. The fan independent-
from 100 to 240 V and 50 to 60 Hz. The fan is suita-
17 1.6 133 ble for application in various countries and has sta-
ly selects the optimum humidity threshold for the
dBA W m3/h room in which it is installed. Fan operation algorithm
ble operation in versatile power mains. is selected based on analysing the statistical data of
• The motor is installed on a rubber anti-vibration indoor humidity level.
connector for vibration absorbing and silent fan op- Automatic operation based on temperature sen-
eration. sor. If the air temperature exceeds the set point, the
• The motor is equipped with overheating protec- fan will switch to Max speed and will return to the
Application tion. previous mode only after indoor temperature drops
by 4 °C below the set point.
• Innovative exhaust fan with stylish design for
MOTION SENSOR / Motion sensor (for
new comfort level in shower rooms, bathrooms,
Modifications the iFan Move Wi-Fi model)
kitchens and other residential premises.
READY
READY
When the motion sensor is activated, the
• Intellectual integrated control functions allow
READY

turn-on delay timer is switched on. Then the fan will


adjusting personal settings for the most balanced CONTROL

microclimate. CONTROL
CONTROL
switch to Silent speed. Once there is no motion de-
tected, and after turn-off delay time the fan will
Model with intellectual humidity control and auto-
switch to standby mode.
Design matic heat distribution.
READY
READY


READY
Specially designed motor and aerodynamically
optimized impeller shape provide super silent oper- CONTROL
CONTROL

CONTROL
ation at only 17 dBA, which is combined with high
air performance. Model with intellectual humidity control, automatic
heat distribution and extra motion sensor control.

Operation modes
The operating mode for the iFan Wi-Fi fan can be se-
lected using an application for Android or iOS.
24 HOURS / Non-stop ventilation
Silent – permanent low-speed operation
mode. If the humidity changes, the fan
switches to a higher speed (MAX mode). The fan is
• Front panel 3D design and rich colour palette of switched to Silent mode after signal from the motion
replaceable decorative panels give zest to the most sensor or external switch.
refined interior. Do not disturb – the function is only available when
• Due to replaceable spigots the fan is suitable for the 24 hours mode is activated. This function allows
mounting with Ø100 or Ø125 mm air ducts. for setting the time interval so that the fan will not re-
spond to sensors or switch actuation, and will oper-
ate at minimum speed (Silent).
TIMER/Turn-on and turn-off delay timers
Turn-on delay timer allows to delay
switching to a higher speed by 2 or 5 min-
utes after sensor activation.
Turn-off delay timer is designed to prolong the fan
operation for 5, 15, 30 or 60 minutes in the mode
• The motor-impeller block is easy to remove with- caused by sensor activation or Boost mode activa-
out special tools which grants easy servicing. tion.

34 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Decorative front panel colours*

Melange Silver Ruby star Violet Topaz Graphite Black Sapphire


*decorative front panels are available upon separate order

Aerodynamic characteristics Overall dimensions


Air flow [l/s]
0 5 10 15 20 25 30 35 Dimensions [mm]
Model
40 ØD B H L L1
Pressure, ΔP [Pa]

100 iFan Wi-Fi


35 100/125 152 206 57 29
125 iFan Move Wi-Fi

30

25

20

H
15

10

B
5

0
0 20 40 60 80 100 120 140
Air flow [m3/h]

Technical data

iFan Wi-Fi
Model
iFan Move Wi-Fi

Duct diameter [mm] 100 125


Speed 24 hours Silent Max 24 hours Silent Max
Frequency [Hz] 50/60
Voltage [V] 100-240
Power [W] 1.6 2.9 5.6 1.7 3 6
Current [A] 0.02 0.04 0.06 0.03 0.04 0.07
RPM [min-1] 950 1650 2150 850 1350 2200
Maximum air flow [m3/h] 33 72 106 40 83 133
Maximum air flow [l/s] 9 20 29 11 23 37
Air flow control range [m3/h] - 33…106 - 40…133
Air flow control range [l/s] - 9…29 - 11…37
SFP [W/l/s] 0.17 0.14 0.19 0.15 0.13 0.16
Sound pressure level at a distance of 3 m [dBA] 17 21 31 17 22 32
IP IP44

Certificates

The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 35


LOW-NOISE AND
ENERGY-SAVING AXIAL FANS

Axial fans
VENTS Quiet Series page
Air flow – up to 370 m /h 3 38

Axial fans
VENTS Quiet DC Series page
Air flow – up to 101 m3/h 40

Axial fans
VENTS Quiet-Style page
Air flow – up to 90 m /h
3
42

Axial fans
VENTS Quiet-S page
Air flow – up to 99 m /h
3
44

Axial fans
VENTS Quiet-Disc page
Air flow – up to 370 m /h 3
46

Axial fans
VENTS Quiet Duo Series page
Air flow – up to 170 m /h 3
48

Axial fans
VENTS Quiet-dMEV DC Series page
Air flow – up to 83 m3/h 50

Axial fans
VENTS Silenta-M Series page
Air flow up to 242 m /h
3
52

Axial fans
VENTS Silenta-S Series page
Air flow up to 240 m /h
3
54

36 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Axial fans
VENTS Style Series page
Air flow up to 97 m /h 3 56

Axial fans
VENTS Style Duo Series page
Air flow up to 90 m /h 3 58

Axial decorative fans


VENTS Solid Series page
Air flow up to 155 m /h3 60

Axial decorative fans


VENTS Wave Series page
Air flow up to 85 m3/h 62

Axial decorative fans


VENTS Flip Series page
Air flow up to 85 m /h
3
64

Axial decorative fans


VENTS MF Series page
Air flow up to 255 m /h3
66

Axial decorative fans


VENTS MF Duo Series page
Air flow up to 300 m3/h 68

Axial decorative fans


VENTS Casto Series page
Air flow up to 255 m3/h 70

Axial decorative fans


VENTS Casto Duo Series page
Air flow up to 300 m /h3
72

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 37


LOW-NOISE AND ENERGY-SAVING AXIAL FANS

VENTS Quiet • Maintenance-free bearings contain enough Mode 3 (two-speed mode)


grease for 40 000 hrs non-stop operation.
• The fan operates at the 1st speed by default.
Series • Motor on special anti-vibration dampers for The fan switches to the 2nd speed when the
vibration absorbing and silent operation. switch is closed or the sensors are activated.
• Motor equipped with overheating protection. Mode 4 (two-speed mode)
• VENTS Quiet 150 supplied with 2 speed • The fan is turned off by default. The fan starts
motor. VENTS Quiet Extra 150 supplied with operating at the 1st speed when the switch is
2 speed high powered motor. closed and switches to the 2nd speed when the
humidity sensor is activated.
Modifications and Options Mode 5 (two-speed mode)
• The fan is turned off by default. The fan starts
Quiet Extra – high-powered motor. operating at the 1st speed when the switch is
closed or when the humidity sensor is activated. If
during the operation at the 1st speed the second
Quiet T – off-delay timer modifica- even takes place. i.e. the switch is closed or the
tion with operating time from 2 to humidity sensor is activated, the fan switches to
30 min. the 2nd speed.
Intellectual axial low-noise and energy-
saving fan for exhaust ventilation Quiet TH – off-delay timer
with air flow up to 370 m3/h modification with the opera­ Control
ting time from 2 to 30 min Manual control:
Application and humidity sensor with threshold from 60
• Manual control with a room light switch. The
• Innovative exhaust fan with stylish design for to 90 %. switch is not included into delivery set.
new comfort level in shower rooms, bathrooms, Quiet V – pull-cord switch modifica-
kitchens and other residential premises. tion.
• The fan is controlled by the built-in pull cord
switch V. Not applied in case of ceiling mounting.
• Maximum air flow combined with low noise • Speed control is possible through a thyristor
level provide the ideal microclimate. Quiet VT – modification speed controller or through speed switch P2-
• Mounting into ventilation shafts or connection with pull-cord switch and 1-300 (only for VENTS Quiet 150 models), see
to Ø 100, 125, 150 mm. off-delay timer with opera­ting Electrical Accessories. Several fans may connected
time from 2 to 30 min. to the same controller. Speed controllers can not
Design
Quiet VTH – be connected to the fans with T, TH, TP, VT, VTH
• Casing and impeller made of high-quality and modification with modification.
durable UV-resistant plastic. pull-cord switch, off- Automatic control:
• Specially designed impeller aerodynamic delay timer with operating time from 2 to 3­ 0 min
• By the electronic control unit BU-1-60 (see
profile provides high air flow and low noise. and humidity sensor with threshold from 60 to Electrical Accessories). The control unit is supplied
90 %.
• The compact design enables wall and ceiling separately.
Quiet TP – modification
mounting.
with off-delay timer with
• By the timer T (the built-in turn-off delay timer
• The shortened spigot for mounting into a operating time from 2 to­
enables the fan operation within 2 to 30 minutes
ventilation shaft or connection to Ø 100, 125, after the fan switching off ).
30 min and motion sensor; reach distance up to 4
150 mm air ducts.
m, viewing angle up to 100°. • By the humidity sensor and timer TH (if the
• The fan is equipped with a specially designed
* Models VENTS Quiet 150 with modification T / TP
humidity level in the room exceeds the sensor
back valve to prevent back flow and heat losses threshold within 60-90  % the fan switches
/ VT / VTH additionaly supplied with turn-on delay automatically on and operates until the humidity
during the fan standby.
timer adjustable from 0 up to 2 minutes. level drops to the standard level, after that the fan
• The fan exhaust spigot incorporates specially continues operating within the set time period
designed air rectifiers to reduce air turbulence,
increase air pressure and lower noise level.
Operation modes of the VENTS and shuts down).
Quiet 150 and VENTS Quiet Extra 150
• High ingress protection rating ensures • By the motion sensor and timer TP (if motion
Operation modes of the fans models VENTS Quiet is detected in the reach area, the fan is switched
makes the fan the ideal solution for ventilation
150 and VENTS Quiet Extra 150 with modifications automatically and operates within the set time
of a bathroom. The electronic components are
T, TH, VT, VTH, TP is selected by setting the DIP period from 2 to 30 min). Reach distance up to
protected with tight covers. Models VENTS Quiet
switch into the required position. 4 m, the max. viewing angle 100°.
150 and VENTS Quiet Extra 150 are additionaly
equipped with a special vibration absorbing Mode 1 (single-speed mode)
sealer along the fan countour. • The fan is turned off by default. The fan starts Mounting features
operating at the 1st speed when the switch is • Installation directly inside a ventilation shaft.
closed or one of the sensors is activated.
Motor • Flexible air ducts may be used in case of remote
Mode 2 (single-speed mode) location of the ventilation shaft. Connection of the
• Low energy demand from 7.5 W due to new • The fan is turned off by default. The fan starts air duct to the exhaust flange with a clamp.
high-efficient motor.
operating at the 2nd speed when the switch is • Wall mounting with screws.
closed or the sensors are activated.
• Suitable for ceiling mounting.

Colour modifications

Quiet 100/125/150 Quiet 100/125/150 Quiet 100/125/150 Quiet 100/125/150 Quiet 100/125/150
Red RAL 3013 Vintage Aluminum Lacquer Chrome Black Sapphire

38 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Technical data

Power Sound Pressure


Frequency Current Maximum air Weight
Model Speed Voltage [V] Consump- Level at 3 m IP
[Hz] [A] capacity [m3/h] [kg]
tion [W] [dBA]
VENTS Quiet 100 50 220-240
– 7.5 0.049 97 25 0.55
VENTS Quiet 100 (220 V/60 Hz) 60 220
IP45
VENTS Quiet 125 50 220-240
– 17 0.11 185 32 0.78
VENTS Quiet 125 (220 V/60 Hz) 60 220
max. 19 0.09 315 33
VENTS Quiet 150 50/60 220-240 1.33
min. 17 0.08 220 28
IP45
max. 22 0.1 370 38
VENTS Quiet Extra 150 50/60 220-240 1.33
min. 19 0.09 280 32

Aerodynamic characteristics
45 120

VENTS Quiet 100 70 VENTS Quiet 125 VENTS Quiet 150


40 VENTS Quiet Extra 150
100
60
35

30 50 80

25
40
60
20
30
15 40

20
10
20
5 10
Air flow [m3/h]
0 0
0
0 10 20 30 40 50 60 70 80 90 100 0 50 100 150 200 250 300 350 400
0 20 40 60 80 100 120 140 160 180 200
Air flow [m3/h] Air flow [m3/h] Air flow [m3/h]

Overall dimensions

Dimensions [mm]
Model
ØD B H L L1
VENTS Quiet 100 99 158 136 81 26
VENTS Quiet 125 123.5 182 158 91 27
VENTS Quiet 150
147.5 214 190 111 32
VENTS Quiet Extra 150

Certificates

The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 39


LOW-NOISE AND ENERGY-SAVING AXIAL FANS

VENTS Quiet DC Motor Mode 4 (two-speed mode)

• Low energy demand up to 3.5 W due to a new • The fan is turned off by default. The fan starts
Series high-efficient motor. operating at the low speed when the switch is
closed and switches to the high speed when the
• Maintenance-free bearings contain enough humidity or motion sensor is activated.
grease for 40 000 hrs non-stop operation.
• Motor equipped with electric overheating pro- Control
tection. Manual control:
Modifications and Options • Manual operation with a room light switch.
The switch is not included in the delivery set.
Quiet DC T: modification with a turn-
off delay timer regulated from 2 up to 30 • Operation with the integrated pull cord switch
V. Not applied in case of ceiling mounting.
minutes. All the Quiet DC fans have this
timer by default. Automatic control:
Quiet DC TH: modification • With the electronic control unit BU-1-60 (see
with a turn-off delay timer Electrical Accessories). The control unit is supplied
D
C E
regulated from 2 up to 30 min- separately.
B

utes and a humidity sensor with an ad­justable • With the turn-off delay timer T. The built-in
A

threshold from 60 to 90 %. turn-off delay timer enables operation of the fan
Quiet DC VT: modification within 2 up to 30 minutes after turning the fan off
Updated version of low-noise axial with a pull cord switch and a with a switch.
fans with DC motors for low energy turn-off delay timer regu­lated • With the humidity sensor and timer TH. If the
consumption from 2 up to 30 minutes. indoor humidity exceeds the set humidity point
Quiet DC VTH: adjustable from 60 to 90 %, the fan switches au-
Application modification with tomatically to the high speed and ope­rates until
a pull cord switch, the humidity level drops below the set point. After
• Innovative extract fan with stylish design for a turn-off delay timer regulated from 2 up to 30 that the fan continues operating according to the
enhanced comfort level in shower rooms, bath- minutes and a humidity sensor with an adjustable timer settings and turns either to the low speed
rooms, kitchens and other residential premises. threshold from 60 to 90 %. or turns off.
• Maximum air flow combined with low noise Quiet DC TP: modification • With the motion sensor and the timer TP. If the
level provide the ideal microclimate. with a turn-off delay timer motion sensor detects motion in the reach area up
to 4 m with a viewing angle up to 100°, the fan
• Mounting into ventilation shafts or connec- regulated from 2 up to 30 min-
turns on and operates from 2 to 30 mi­nutes ac-
tion to Ø 100 mm air ducts. utes and a motion sensor with reach distance up
to 4 m and viewing angle up to 100°. cording to the timer settings.
• Two-speed operation modes with max. air
flow 100 m3/h. Operation modes of Quiet 100 DC Mounting features
Design
fan with an integrated turn-off • Installation directly inside a ventilation shaft.
delay timer, humidity sensor • Flexible air ducts may be used in case of re-
• The casing and the impeller are made of high- and motion sensor. mote location of the ventilation shaft. The air duct
quality and durable UV-resistant plastic. is connected to the exhaust spigot with a fixing
Operation mode selection and setup for Quiet 100
• The specially designed aerodynamic profile of DC models with modifications T, TH, VT, VTH, TP is clamp.
the mixed-flow impeller provides high air flow and
pressure combined with low-noise operation.
performed by setting the DIP switch to a respec- • Wall mounting with screws.
tive position.
• Suitable for ceiling mounting.
• A shortened spigot for mounting into a venti- Mode 1 (single-speed mode)
lation shaft or direct connection to Ø 100 mm air
duct. • The fan is turned off by default. The fan starts
operating at the low speed when the switch is
• The fan is equipped with a specially designed closed or one of the sensors is activated.
backdraft damper to prevent back flow and heat
Mode 2 (single-speed mode)
losses during the fan standby.
• The fan exhaust spigot incorporates special- • The fan is turned off by default. The fan starts
operating at the high speed when the switch is
ly designed air rectifiers to reduce air turbulance,
closed or one of the sensors is activated.
noise level and boost air pressure.
Mode 3 (two-speed mode)
• High ingress protection rating makes the fan
• The fan operates at the low speed by default.
the ideal solution for ventilation of a bathroom.
The fan switches to the high speed when the
The electronic components are protected with
switch is closed or the sensors are activated.
tight covers.

Colour modifications

Quiet 100 DC Quiet 100 DC Quiet 100 DC Quiet 100 DC Quiet 100 DC
Red RAL 3013 Vintage Aluminum Lacquer Chrome Black Sapphire

40 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Technical data

Power Maximum air Sound Pressure


Frequency Voltage Current Weight
Model Speed consumption R.p.m. capacity Level at 3 m IP
[Hz] [V] [A] [kg]
[W] [m3/h] [dBA]
min. 1.5 0.063 1850 70 22
VENTS Quiet DC 50/60 220-240 0.55 IP45
max. 3.5 0.137 2650 101 27

Aerodynamic characteristics
70

VENTS Quiet 100 DC


60

50

40

30
max
20

min
10

0
0 20 40 60 80 100
Air flow [m3/h]

Overall dimensions

Dimensions [mm]
Model
ØD B H L L1
VENTS Quiet DC 99 158 136 81 26

Certificates

The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 41


LOW-NOISE AND ENERGY-SAVING AXIAL FANS

VENTS Quiet-Style Motor Control


Series • Low energy demand 7.5 W due to new high- Manual control:
efficient motor. • Manual control with a room light switch. The
switch is not included into delivery set.
• Maintenance-free bearings contain enough
grease for 40 000 hrs non-stop operation. • The fan is controlled by the built-in pull cord
switch V. Not applied in case of ceiling mounting.
• Motor on special anti-vibration dampers for vi-
bration absorbing and silent operation. • Speed control is possible through a thyristor
speed controller, see Electrical Accessories. Sev-
• Motor equipped with overheating protection.
eral fans may connected to the same controller.
Speed controllers can not be connected to the
Modifications and Options fans with T, TH, VT, VTH modification.
Quiet-Style T – off-delay timer mod- Automatic control:
ification with operating time from 2 to
30 min.
• By the electronic control unit BU-1-60 (see
Electrical Accessories). The control unit is supplied
Quiet-Style TH – off-delay separately.
timer modification with the
opera­ting time from 2 to 30
• By the timer T (the built-in turn-off delay timer
enables the fan operation within 2 to 30 minutes
min and humidity sensor with threshold from 60 after the fan switching off ).
to 90 %.
Intellectual axial low-noise and energy- Quiet-Style V – pull-cord switch mod-
• By the humidity sensor and timer TH (if the
humidity level in the room exceeds the sensor
saving fan for exhaust ventilation ification. threshold within 60-90  % the fan switches auto-
with air flow up to 90 m3/h matically on and operates until the humidity level
Quiet-Style VT – modifica- drops to the standard level, after that the fan con-
tion with pull-cord switch and tinues operating within the set time period and
Application off-delay timer with opera­ting shuts down).
time from 2 to 30 min.
• Innovative exhaust fan with stylish design for Mounting features
new comfort level in shower rooms, bathrooms, Quiet-Style VTH –
kitchens and other residential premises. modification with • Installation directly inside a ventilation shaft.
pull-cord switch, off-
• Maximum air flow combined with low noise delay timer with operating time from 2 to 3­ 0 min
• Flexible air ducts may be used in case of re-
level provide the ideal microclimate. mote location of the ventilation shaft. Connection
and humidity sensor with threshold from 60 to of the air duct to the exhaust flange with a clamp.
• Mounting into ventilation shafts or connec- 90 %.
tion to Ø 100 mm. • Wall mounting with screws.
• Suitable for ceiling mounting.
Design
• Casing, impeller and frontpanels made of
high-quality and durable UV-resistant plastic.
• Specially designed impeller aerodynamic pro-
file provides high air flow and low noise.
• The compact design enables wall and ceiling
mounting.
• The shortened spigot for mounting into a ven-
tilation shaft or connection to Ø 100 mm air ducts.
• The fan is equipped with a specially designed
back valve to prevent back flow and heat losses
during the fan standby.
• The fan exhaust spigot incorporates specially
designed air rectifiers to reduce air turbulence, in-
crease air pressure and lower noise level.
• High ingress protection rating ensures makes
the fan the ideal solution for ventilation of a bath-
room. The electronic components are protected
with tight covers.

Colour modifications

Quiet-Style A
(with a decorative aluminium
surface-mounted panel)

42 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Technical data

Sound Pressure
Frequency Power Current Maximum air Weight,
Model Voltage [V] Level at 3 m IP
[Hz] Consumption [W] [A] capacity [m3/h] kg
[dBA]
VENTS Quiet-Style 100 50 220-240
VENTS Quiet-Style 7.5 0.050 90 26 0.66 IP45
60 220
100 (220 V/60 Hz)

Aerodynamic characteristics
30

VENTS Quiet-Style 100


25

20

15

10

0
0 10 20 30 40 50 60 70 80 90 100
Air flow [m3/h]

Overall dimensions
Dimensions [mm]
Model
ØD B L L1
VENTS Quiet-Style 100 99 200 130 49

Certificates

The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 43


LOW-NOISE AND ENERGY-SAVING AXIAL FANS

VENTS Quiet-S Design Control


Series • Casing, impeller and frontpanels made of Manual control:
high-quality and durable UV-resistant plastic. • Manual control with a room light switch. The
switch is not included into delivery set.
• Specially designed impeller aerodynamic
profile provides high air flow and low noise. • The fan is controlled by the built-in pull cord
switch V. Not applied in case of ceiling mounting.
• The compact design enables wall and ceiling
mounting. • Speed control is possible through a thyristor
speed controller, see Electrical Accessories. Several
• The shortened spigot for mounting into a
fans may connected to the same controller. Speed
ventilation shaft or connection to Ø 100 mm air
ducts. controllers can not be connected to the fans with
T, TH, VT, VTH, TP modification.
• The fan is equipped with a specially designed Automatic control:
back valve to prevent back flow and heat losses
during the fan standby. • By the electronic control unit BU-1-60 (see
Electrical Accessories). The control unit is supplied
• The fan exhaust spigot incorporates specially separately.
designed air rectifiers to reduce air turbulence,
increase air pressure and lower noise level. • By the timer T (the built-in turn-off delay timer
enables the fan operation within 2 to 30 minutes
• High ingress protection rating ensures
after the fan switching off ).
makes the fan the ideal solution for ventilation
Intellectual axial low-noise and energy- of a bathroom. The electronic components are • By the humidity sensor and timer TH (if the
protected with tight covers. humidity level in the room exceeds the sensor
saving fan for exhaust ventilation threshold within 60-90  % the fan switches
with air flow up to 99 m3/h automatically on and operates until the humidity
Motor
level drops to the standard level, after that the fan
• Low energy demand 7.5 W due to new high- continues operating within the set time period
Application efficient motor. and shuts down).
• Innovative exhaust fan with stylish design for • Maintenance-free bearings contain enough Mounting features
new comfort level in shower rooms, bathrooms, grease for 40 000 hrs non-stop operation.
kitchens and other residential premises. • Motor on special anti-vibration dampers for • Installation directly inside a ventilation shaft.
• Maximum air flow combined with low noise vibration absorbing and silent operation. • Flexible air ducts may be used in case of remote
level provide the ideal microclimate. • Motor equipped with overheating protection. location of the ventilation shaft. Connection of the
air duct to the exhaust flange with a clamp.
• Mounting into ventilation shafts or connection
to Ø 100 mm. Modifications and Options • Wall mounting with screws.

Quiet-S T – off-delay timer modifi- • Suitable for ceiling mounting.


cation with operating time from 2 to
30 min.
Quiet-S TH – off-delay timer
modification with the opera­
ting time from 2 to 30 min
and humidity sensor with threshold from 60
to 90 %.
Quiet-S V – pull-cord switch modifica-
tion.

Quiet-S VT – modification
with pull-cord switch and
off-delay timer with opera­ting
time from 2 to 30 min.
Quiet-S VTH –
modification with
The delivery set includes three pull-cord switch, off-
decorative panels in white, blue and delay timer with operating time from 2 to 3­ 0 min
green. and humidity sensor with threshold from 60 to
90 %.
Quiet-S TP – modification
with off-delay timer with
operating time from 2 to­
30 min and motion sensor; reach distance up to 4
m, viewing angle up to 100°.

44 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Technical data

Sound Pressure
Frequency Power Current Maximum air Weight,
Model Voltage [V] Level at 3 m IP
[Hz] Consumption [W] [A] capacity [m3/h] kg
[dBA]
VENTS Quiet-S 100 50 220-240
VENTS Quiet-S 100 7.5 0.049 99 24 0.58 IP45
60 220
(220 V/60 Hz)

Aerodynamic characteristics
45

VENTS Quiet-S 100


40

35

30

25

20

15

10

0
0 10 20 30 40 50 60 70 80 90 100
Air flow [m3/h]

Overall dimensions

Dimensions [mm]
Model
ØD B L L1
VENTS Quiet-S 100 99 175 123 42

Certificates

The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 45


LOW-NOISE AND ENERGY-SAVING AXIAL FANS

VENTS Quiet-Disc • Motor on special anti-vibration dampers for vi- Mode 3 (two-speed mode)
bration absorption and silent operation.
• The fan operates at the 1st speed by default.
Series • Motor equipped with overheating protection. The fan switches to the 2nd speed when the
switch is closed or the sensors are activated.
• The VENTS Quiet-Disc 150 is supplied with a
two-speed motor. The VENTS Quiet-Disc Extra 150 Mode 4 (two-speed mode)
is supplied with a two-speed high powered mo-
tor.
• The fan is turned off by default. The fan starts
operating at the 1st speed when the switch is
closed and switches to the 2nd speed when the
Modifications and Options humidity sensor is activated.
Quiet-Disc Extra – high-powered mo- Mode 5 (two-speed mode)
tor. • The fan is turned off by default. The fan starts
operating at the 1st speed when the switch is
closed or when the humidity sensor is activated.
Quiet-Disc T – turn-off delay timer If during the operation at the 1st speed the sec-
modification with operating time from ond even takes place. i.e. the switch is closed or
2 to 30 min. the humidity sensor is activated, the fan switches
to the 2nd speed.
Intellectual axial low-noise and energy- Quiet-Disc TH – turn-off de-
saving fan for exhaust ventilation lay timer modification with Control
with air flow up to 370 m3/h opera­ting time from 2 to 30
min and a humidity sensor with threshold from 60 Manual control:
Application to 90 %. • Manual control with a room light switch. The
switch is not included in the delivery set.
• Innovative exhaust fan with stylish design for Quiet-Disc V – pull-cord switch mod-
new comfort level in shower rooms, bathrooms, ification. • The fan is controlled by the built-in pull cord
kitchens and other residential premises. switch V. Not applied in case of ceiling mounting.
• Maximum air flow combined with low noise Quiet-Disc VT – modification • Speed control is possible through a thyris-
level provide the ideal microclimate. tor speed controller or through a P2-1-300 speed
with a pull-cord switch and
switch (only for VENTS Quiet-Disc 150 models), see
• Mounting into ventilation shafts or connec- a turn-off delay timer with
Electrical Accessories. Several fans may be con-
tion to Ø 100, 125, 150 mm. opera­ting time from 2 to 30 min.
nected to the same controller. Speed controllers
Design Quiet-Disc VTH – can not be connected to the fans with the T, TH, TP,
modification with a VT, VTH modifications.
• Casing and impeller made of high-quality and pull-cord switch, a
Automatic control:
durable UV-resistant plastic. turn-off delay timer with operating time from 2 to
• Specially designed impeller aerodynamic pro- ­30 min and a humidity sensor with threshold from • By the electronic control unit BU-1-60 (see
file provides high air flow and low noise. 60 to 90 %. Electrical Accessories). The control unit is supplied
separately.
• The compact design enables wall and ceiling Quiet-Disc TP – modification
mounting. with a turn-off delay timer • By the timer T (the built-in turn-off delay timer
with operating time from 2 to­ enables the fan operation within 2 to 30 minutes
• The shortened spigot for mounting into a 30 min and a motion sensor; reach distance up to after the fan switching off ).
ventilation shaft or connection to Ø 100, 125,
150 mm air ducts.
4 m, viewing angle up to 100°. • By the humidity sensor and timer TH (if the
* The VENTS Quiet-Disc 150 models with the T/TP/ humidity level in the room exceeds the sensor
• The fan is equipped with a specially designed VT/VTH modifications are additionaly supplied threshold within 60-90  % the fan switches auto-
back valve to prevent back flow and heat losses
with a turn-on delay timer adjustable from 0 up matically on and operates until the humidity level
during the fan standby.
to 2 minutes. drops to the standard level, after that the fan con-
• The fan exhaust spigot incorporates specially tinues operating within the set time period and
designed air rectifiers to reduce air turbulence, in- shuts down).
crease air pressure and lower noise level.
VENTS Quiet-Disc 150 and VENTS Qui-
et-Disc Extra 150 operation modes • By the motion sensor and timer TP (if motion
• High ingress protection rating makes the
Operation modes of the fans models VENTS Qui- is detected in the reach area, the fan is switched
fan the ideal solution for ventilation of a bath- automatically and operates within the set time
et-Disc 150 and VENTS Quiet-Disc Extra 150 with
room. The electronic components are protected period from 2 to 30 min). Reach distance up to
modifications T, TH, VT, VTH, TP are selected by set-
with tight covers. The VENTS Quiet-Disc 150 and 4 m, the max. viewing angle 100°.
ting the DIP switch into the required position.
VENTS Quiet-Disc Extra 150 models are addition-
aly equipped with a special vibration absorbing Mounting features
sealer along the fan countour. Mode 1 (single-speed mode)
• The fan is turned off by default. The fan starts
• Installation directly inside a ventilation shaft.
operating at the 1st speed when the switch is • Flexible air ducts may be used in case of re-
Motor closed or one of the sensors is activated. mote location of the ventilation shaft. Connection
of the air duct to the exhaust flange with a clamp.
• Low energy demand from 7.5 W due to new Mode 2 (single-speed mode)
high-efficient motor.
• The fan is turned off by default. The fan starts • Wall mounting with screws.

• Maintenance-free bearings contain enough operating at the 2nd speed when the switch is • Suitable for ceiling mounting.
grease for 40 000 hrs non-stop operation. closed or the sensors are activated.

Colour modifications

Quiet-Disc 100/125/150 Quiet-Disc 100/125/150 Quiet-Disc 100/125/150 Quiet-Disc 100/125/150 Quiet-Disc 100/125/150
Red Vintage Aluminum Lacquer Chrome Black Sapphire

46 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Technical data

Power Sound pressure


Frequency Voltage Current Maximum air Weight
Model Speed consump- level at 3 m IP
[Hz] [V] [A] flow [m3/h] [kg]
tion [W] [dBA]
VENTS Quiet-Disc 100 50 220-240
– 7.5 0.049 97 25 0.55
VENTS Quiet-Disc 100 (220 V/60 Hz) 60 220
IP45
VENTS Quiet-Disc 125 50 220-240
– 17 0.11 185 32 0.78
VENTS Quiet-Disc 125 (220 V/60 Hz) 60 220
max. 19 0.09 315 33
VENTS Quiet-Disc 150 50/60 220-240 1.33
min. 17 0.08 220 28
IP45
max. 22 0.1 370 38
VENTS Quiet-Disc Extra 150 50/60 220-240 1.33
min. 19 0.09 280 32

Aerodynamic characteristics
45 120

VENTS Quiet-Disc 100 70 VENTS Quiet-Disc 125 VENTS Quiet-Disc 150


40 VENTS Quiet-DiscExtra 150
100
60
35

30 50 80

25
40
60
20
30
15 40

20
10
20
5 10

0 0
0
0 10 20 30 40 50 60 70 80 90 100 0 50 100 150 200 250 300 350 400
0 20 40 60 80 100 120 140 160 180 200
Air flow [m3/h] Air flow [m3/h] Air flow [m3/h]

Overall dimensions
Dimensions [mm]
Model
ØD B H L L1
VENTS Quiet-Disc 100 99 158 136 81 26
VENTS Quiet-Disc 125 123.5 182 158 91 27
VENTS Quiet-Disc 150
147.5 214 190 111 32
VENTS Quiet-Disc Extra 150

Certificates

The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 47


LOW-NOISE AND ENERGY-SAVING AXIAL FANS

VENTS Quiet Duo • The fan exhaust spigot incorporates special- Control
ly designed air rectifiers to reduce air turbulance,
Manual control:
Series noise level and boost air pressure.
• High ingress protection rating makes the fan • Manual control with a room light switch. The
the ideal solution for bathroom ventilation. The switch is not included in the delivery set.
electronic components are protected with tight The fan is controlled by the built-in pull cord
covers. switch V. Not applied in case of ceiling moun-
ting.
Motor Speed control with the thyristor speed controller
or speed switch P2-1-300, see Electrical Accesso-
• Low energy demand from 4 W due to a new ries. Several fans may be connected to the same
two-speed high-efficient motor. controller. Speed controllers are not compatible
• Maintenance-free bearings contain enough with the fans with T, TH modification.
grease for 40 000 hrs non-stop operation. Automatic control:
• Motor on special anti-vibration dampers for vi- • By the electronic control unit BU-1-60 (see
bration absorbing and silent operation. Electrical Accessories). The control unit is supplied
• Motor equipped with overheating protection. separately.

Two-speed axial low-noise and low


• By the timer T. The built-in turn-off delay timer
Modifications and Options* enables the fan operation at the high speed within
energy fans for exhaust ventilation 2 to 30 minutes after the fan switching off.
with the capacity up to 170 m3/h Quiet Duo V: modification with a pull
cord switch. • By the humidity sensor and timer TH. If the
humidity level in the room exceeds the sensor
threshold within 60-90  % the fan switches auto-
Quiet Duo T: modification matically to the high speed and operates until the
with a turn-off delay timer and humidity level drops to the standard level. After
inverval timer – integrated that the fan continues operating within the set
Application function of automatic ventilation activation. time period and then reverts to the standard op-
eration mode with the low speed.
• Innovative exhaust fan with stylish design. Once in 6, 14 or 24 hours the fan is switched on for
up to 30 min to ventilate a premise with the low
• Ideal for intermittent or continuous ventilation
speed. On elapsing of the set run-out time the fan Mounting features
of bathroom, showers, kitchens and other utility
spaces. switches off automatically. • Installation directly inside a ventilation shaft.

• Two-speed ventilation up to 170 m3/h. • Flexible air ducts may be used in case of remote
Quiet Duo TH: off-delay tim- location of the ventilation shaft. The air duct is con-
• Permanent low-speed operation mode en-
er modification with a turn-off nected to the exhaust spigot with a fixing clamp.
sures continuous minimum air exchange in the
room. delay from 2 to 30 min and hu- • Wall mounting with screws.
midity sensor with an adjustable thres-hold from
• Mounting into ventilation shafts or con­nection 60 to 90 %.
to Ø 100 mm and 125 mm air ducts.
* VENTS Quiet 100 Duo and VENTS Quiet 125 Duo
with modifications T and TH are supplied with an
Design integrated switch delay timer to avoid the fan un-
necessary switching if you use your bathroom
• The casing and the impeller are made of high- shortly and frequently. After humidity increases or
quality and durable UV-resistant plastic.
after signalling from the external switch, the fan
• The specially designed aerodynamic profile switches to higher speed not immediately, but af-
of the mixed-flow impeller provides high air flow ter the set timer countdown (1 min).
combined with low-noise operation.
• The compact design enables wall and ceiling Operation modes of the fans with
installation. modifications T, TH:
• A shortened spigot for mounting into a venti- The fan operates at the low speed by default. The
lation shaft or direct connection to Ø 100 mm and fan switches to the high speed when the switch is
125 mm air duct. closed or the humidity sensor is activated.
• The fan is equipped with a specially designed
back valve to prevent back flow and heat losses
during the fan standby.

Colour modifications

Quiet 100/125 Duo Quiet 100/125 Duo Quiet 100/125 Duo Quiet 100/125 Duo Quiet 100/125 Duo
Red RAL 3013 Vintage Aluminum Lacquer Chrome Black sapphire

48 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Aerodynamic characteristics

50 60

45
55 VENTS Quiet 125 Duo
VENTS Quiet 100 Duo
50
40
45
35
40
30 35

25 30
max
max
25
20 min
min 20
15
15
10
10
5 5

0 0
0 10 20 30 40 50 60 70 80 90 0 25 50 75 100 125 150 175
Air flow [m3/h] Air flow [m3/h]

Technical data

Fre- Power Sound pressure


Voltage Current Maximum air Weight
Model Speed quency consump- level at 3 m IP
[V] [A] capacity [m3/h] [kg]
[Hz] tion [W] [dBA]

max 4 0.029 60 22
VENTS Quiet 100 Duo 50/60 220-240 0.55 IP45
min 7.5 0.052 90 25
max 9.5 0.065 145 28
VENTS Quiet 125 Duo 50/60 220-240 0.78 IP45
min 13.5 0.09 170 32

Overall dimensions
Overall dimensions [mm]
Model
ØD B H L L1
VENTS Quiet 100 Duo 99 158 136 81 26
VENTS Quiet 125 Duo 123.5 182 158 91 27

Certificates

The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 49


LOW-NOISE AND ENERGY-SAVING AXIAL FANS

Series Motor Operation mode 2

• High-efficient direct current motor with low • The fan runs with the Trickle speed by default.
VENTS Quiet-dMEV DC energy consumption of maximum 3.4 W. In case of actuation of the switch the turn-on delay
timer countdown starts and then the fan starts to
• Maintenance-free bearings are greased for run with the Boost speed. After turning the fan off
40 000 hrs of non-stop operation.
the turn-off delay timer is activated.
• The motor is equipped with overheating pro-
Operation mode 3
tection.
• The fan runs with the Trickle speed by default.
Modifications and Options In case of actuation of the humidity sensor the fan
goes to the Boost speed mode. After decrease of
Quiet-dMEV DC 12: modification with the indoor humidity below the set threshold the
safe low-voltage 12 V ac motor. turn-off delay timer is activated.

Control
Quiet-dMEV DC T: timer modification
with a fixed turn-on delay of 60 s and a Manual control:
C
D E
regulated turn-off delay from 2 up to 30 • Manual operation with a room light switch.
minutes. The light switch is not included in the delivery set.
B

• Manual operation with the integrated pull cord


A

Quiet-dMEV DC TH: modifica-


tion with a turn-off delay timer switch V. Not applied in case of ceiling mounting.
regulated from 2 up to 30 min-
Updated version of low-noise axial Automatic control:
utes and a humidity sensor with an adjustable
fans with DC motors for low energy threshold from 60 to 90 % RF. • Automatic control with the electronic control
consumption unit BU-1-60 (seeElectrical Accessories). The con-
Quiet-dMEV DC VT: modifi-
trol unit is supplied separately.
cation with a pull cord switch
Application and a turn-off delay timer reg- • Automatic control with the timer T: the in-
ulated from 2 up to 30 minutes. tegrated timer with turn-on and turn-off delay
• Innovative extract fan with stylish design for functions enables to switch the fan to the inten-
enhanced comfort level in shower rooms, bath- Quiet-dMEV DC VTH:
sive operation mode 60 seconds after the switch
rooms, kitchens and other residential premises. modificati­­on with
actuation and to keep the fan running from 2 to
a pull cord switch,
• Maximum air flow combined with low noise a turn-off delay timer regulated from 2 up to 30
30 minutes after it is turned off with the switch.
level provides the ideal indoor microclimate.
minutes and a humidity sensor with an adjustable • Automatic control with the humidity sensor
• Mounting into ventilation shafts or connec- threshold from 60 to 90 % RF. and timer TH: as the indoor humidity exceeds
tion to Ø 100 mm air ducts. the set threshold from 60  % up to 90  %, the fan
• Two operation modes with the speed up to turns automatically on or goes to higher speed
100 m3/h Operation modes of Quiet-dMEV 100 and runs until the humidity decreases below the
DC fan with a pull cord switch, set threshold.
Design integrated turn-on and turn-off • After that the fan continues to run within the
set time period and then turns off or goes to lower
• The casing and the impeller are made of high- delay timer and a humidity sensor
speed.
quality and durable UV-resistant plastic. Operation mode selection and setup for the
• The specially designed aerodynamic profile of Quiet-dMEV 100 DC models with T, TH, VT, VTH op-
the mixed-flow impeller provides high air capac- tions is performed by setting the DIP switch to a Mounting features
ity, powerful pressure and low operation noise. respective position.
• Direct installation inside a ventilation shaft.
• A shortened spigot enables to mount the fan Trickle speed modes:
• In case of remote location of the ventilation
into a ventilation shaft or connect it to a Ø 100 mm 1 – 0 l/s: the fan is off shaft flexible air ducts may be used.
air duct.
• The specially designed air backdraft damp-
2 – 6 l/s: the fan runs with the speed 2 • The air duct is connected to the exhaust spigot
3 – 8 l/s: the fan runs with the speed 3 with a fixing clamp.
er prevents air backdraft and heat losses during
standstill of the fan. 4 – 13 l/s: the fan runs with the speed 4 • Wall mounting with screws.
• The fan exhaust spigot is equipped with spe- Intensive operation modes (Boost) • Suitable for ceiling mounting.
cially designed air rectifiers that reduce air turbu- 5 – 15 l/s: the fan runs with the speed 5
lence, noise level and boost air pressure.
6 – max: the fan runs with the highest speed.
• High ingress protection rating makes the fan
Operation mode 1
the ideal solution for ventilation of a bathroom.
• The electronic components are protected with • The fan runs with the Trickle speed by default.
In case of actuation of the pull cord switch the fan
tight covers.
goes to the Boost speed mode.

Colour modifications

Quiet-dMEV 100 DC Quiet-dMEV 100 DC Quiet-dMEV 100 DC Quiet-dMEV 100 DC Quiet-dMEV 100 DC
Red Vintage Aluminum Lacquer Chrome Black Sapphire

50 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Technical data

Frequency Power Sound Pressure


Model Speed Voltage [V] Current [A] Air capacity Specific Power
[Hz] Consumption [W] Level at 3 m [dBA]

min. max. [m3/h] [l/s] W/l/s


Trickle Low 0.014 0.6 0.7 22 6 0.10 10
Trickle Middle 0.017 0.8 0.9 29 8 0.10 11
Quiet-dMEV 100 DC Trickle High 50/60 220-240 0.024 1.3 1.7 47 13 0.10 13
Boost Low 0.028 1.9 2.1 54 15 0.13 14
Boost High 0.039 3.0 3.4 83 23 0.15 21

Aerodynamic characteristics Overall dimensions


Air flow [l/s]
0 5 10 15 20 25
Dimensions [mm]
Model
80 ØD B H L L1
Static pressure ΔР [Pa]

VENTS Quiet-dMEV 100 DC VENTS Quiet-dMEV 100 DC 99 158 136 81 26


70

60

50

40

30

20

10

0
0 10 20 30 40 50 60 70 80 90
Air flow [m3/h]

Certificates

The fans meet the applicable safety and electromagnetic compatibility standards

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 51


LOW-NOISE AND ENERGY-SAVING AXIAL FANS

VENTS Silenta-M Design Control


Series • Modern design and aesthetic look. Manual:

• The casing and the impeller are made of high- • The fan is controlled by a room light switch. It
quality durable ABS plastic, UV resistant. is not included in the delivery package.

• The intellectual impeller design makes the fan • The fan is controlled by the built-in pull cord
efficiency high and the service life long. switch V. Not applied in case of ceiling mounting.

• The fan and motor are specially designed for • Speed control is possible through a thyristor
silent operation. speed controller (see Electrical Accessories).
Several fans may connected to the same controller.
• Protection rating IP34. Speed controllers can not be connected to the
fans with T, TH, TP, VT, VTH modification.
Motor
Automatic:
• Reliable motor with the minimum power
• By the electronic control unit BU-1-60 (see
consumption 7 W (for 100 mm diameter).
Electrical Accessories). The control unit is supplied
• Designed for continuous operation and separately.
requires no maintenance.
• By the timer T (the built-in turn-off delay timer
• Equipped with overheating protection. enables the fan operation within 2 to 30 minutes
after the fan switching off ).
Low-noise and low-watt axial fans for Modifications and Options • By the humidity sensor and timer TH (if the
exhaust ventilation with air flow up to Silenta-M K – fan is equipped with humidity level in the room exceeds the sensor
242 m3/h a backdraft damper for back flow threshold adjustable value within 60-90 % the fan
preventing. switches automatically on and operates until the
humidity level drops to the standard level, after
Silenta-M L – the motor is equipped that the fan continues operating within the time
Application with ball bearings for long service period according to the timer setting, then shuts
• Continuous or periodic exhaust ventilation life (appr. 40 thousand hours) and down).
of bathroom, showers, kitchens and other utility fan mounting at any angle. The bearings are
spaces. maintenance-free and contain enough grease for • By the motion sensor and the timer TP (in case
the entire operating period. of motion detection the fan switches automatically
• Ventilation of premises with high noise level Silenta-MT – equipped with a
on and operates within the set time period from
limitations. 2 to 30 minutes. The motion sensitivity area is up
regulated timer with the operating to 4 meters and the maximum detection angle is
• Ventilation shaft mounting or duct connec-
time from 2 to 30 minutes. 100°).
tion.
Silenta-MTH – equipped
• Compatible with Ø 100, 125 and 150 mm air with a timer with the Mounting features
ducts.
operating time from 2 to 30
minutes and a humidity sensor with the threshold
• The fan is mounted directly into the ventilation
shaft.
value from 60 to 90 %.
Silenta-MV – equipped with a pull
• Flexible duct application is recommended in
case of remote location of the ventilation shaft.
cord switch. The air duct is connected to the fan exhaust flange
through a clamp.
Silenta-MVT – equipped • Fixed to wall by self-tapping screws.
with a pull cord switch and
a regulated timer with the • Suitable for ceiling mounting.
operating time adjustable from 2 to 30 minutes.
Silenta-MVTH –
equipped with a
pull cord switch,
regulated timer with the operating time adjustable
from 2 to 30 minutes and a humidity sensor with
the operating threshold range from 60 to 90 %.
Silenta-MTP – equipped
with a regulated timer and
a motion sensor with the
sensitivity area from 1 to 4 m and the detection
angle up to 100°.

Accessories
Backdraft
Air ducts Grilles and hoods damper Speed controllers Clamps

52 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Aerodynamic characteristics

Air flow [m3/h] Air flow [m3/h] Air flow [m3/h]

Technical data

Sound Pressure
Frequency Power Current Maximum air
Model Voltage [V] Level at 3 m Weight, kg
[Hz] Consumption [W] [A] capacity [m3/h]
[dBA]

VENTS 100 Silenta-M 50/60 220-240 7 0.035 78 26 0.48


VENTS 125 Silenta-M 50/60 220-240 9.1 0.059 152 31 0.63
VENTS 150 Silenta-M 50 220-240
VENTS 150 Silenta-M 20 0.14 242 33 0.82
60 220
(220 V/60 Hz)
Air flow [m3/h] Air flow [m3/h] Air flow [m3/h]

Overall dimensions

Dimensions [mm]
Model
ØD B H L L1
VENTS 100 Silenta-M 100 159 135 89 23
VENTS 125 Silenta-M 125 180 150 94 25
VENTS 150 Silenta-M 150 206 182 106 26

Mounting example

Certificates

The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 53


LOW-NOISE AND ENERGY-SAVING AXIAL FANS

VENTS Silenta-S Design Control


Series • Modern design and aesthetic look. Manual:

• The casing and the impeller are made of high- • The fan is controlled by a room light switch. It
quality durable ABS plastic, UV resistant. is not included in the delivery package.

• The intellectual impeller design makes the fan • The fan is controlled by the built-in pull cord
efficiency high and the service life long. switch V. Not applied in case of ceiling mounting.

• The fan and motor are specially designed for • Speed control is possible through a thyristor
silent operation. speed controller (see Electrical Accessories).
Several fans may connected to the same controller.
• Insect screen. Speed controllers can not be connected to the
• Protection rating IP34. fans with T, TH, TP, VT, VTH modification.
Automatic:
Motor
• By the electronic control unit BU-1-60 (see
Electrical Accessories). The control unit is supplied
• Reliable motor with the minimum power separately.
consumption 7 W (for 100 mm diameter).
• Designed for continuous operation and • By the timer T (the built-in turn-off delay timer
requires no maintenance. enables the fan operation within 2 to 30 minutes
after the fan switching off ).
• Equipped with overheating protection.
Low noise and low watt axial fans for • By the humidity sensor and timer TH (if the
humidity level in the room exceeds the sensor
exhaust ventilation with the capacity Modifications and Options threshold adjustable value within 60-90 % the fan
up to 240 m3/h Silenta-S K – fan is equipped with switches automatically on and operates until the
a backdraft damper for back flow humidity level drops to the standard level, after
preventing. that the fan continues operating within the time
Application period according to the timer setting, then shuts
Silenta-S L – The motor is equipped
down).
• Continuous or periodic exhaust ventilation with ball bearings for long service
of bathroom, showers, kitchens and other utility life (appr. 40 thousand hours) and
spaces.
Mounting features
fan mounting at any angle. The bearings are
• Ventilation of premises with high noise level maintenance-free and contain enough grease for • The fan is mounted directly into the ventilation
the entire operating period. shaft.
limitations.
• Ventilation shaft mounting or duct connec- Silenta-ST – equipped with a regulated • Flexible duct application is recommended in
timer with the operating time from 2 to case of remote location of the ventilation shaft.
tion.
30 minutes. The air duct is connected to the fan exhaust flange
• Compatible with Ø 100, 125 and 150 mm air Silenta-STH – equipped with
through a clamp.
ducts.
a timer with the operating • Fixed to wall by self-tapping screws.
time from 2 to 30 minutes and • Suitable for ceiling mounting.
a humidity sensor with the threshold value from
60 to 90 %.
Silenta-SV – equipped with a pull cord
switch.

Silenta-SVT – equipped
with a pull cord switch and
a regulated timer with the
operating time adjustable from 2 to 30 minutes.
Silenta-SVTH –
equipped with a
pull cord switch,
regulated timer with the operating time adjustable
from 2 to 30 minutes and a humidity sensor with
the operating threshold range from 60 to 90 %.

Accessories
Backdraft
Air ducts Grilles and hoods damper Speed controllers Clamps

54 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Air flow [m3/h] Air flow [m3/h] Air flow [m3/h]
Aerodynamic characteristics

Air flow [m3/h] Air flow [m3/h] Air flow [m3/h]

Technical data

Sound Pressure
Frequency Power Current Maximum air
Model Voltage [V] Level at 3 m Weight, kg
[Hz] Consumption [W] [A] capacity [m3/h]
[dBA]

VENTS 100 Silenta-S 50/60 220-240 7 0.035 78 26 0.52


VENTS 125 Silenta-S 50/60 220-240 9.3 0.06 148 31 0.69
VENTS 150 Silenta-S 50 220-240
VENTS 150 Silenta-S 20 0.14 240 33 0.85
60 220
(220 V/60 Hz)

Overall dimensions

Dimensions [mm]
Model
ØD B H L L1
VENTS 100 Silenta-S 100 150 120 108 12
VENTS 125 Silenta-S 125 176 140 114 13
VENTS 150 Silenta-S 150 205 165 132 14

Mounting example

Certificates

The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 55


LOW-NOISE AND ENERGY-SAVING AXIAL FANS

VENTS Style • The integrated thermal actuator enables


smooth opening and closing of the front panel to
Control
Series prevent backdrafting. Manual
The fan is controlled by a room light switch (not
Motor included in the delivery set).
Automatic
• Reliable ball bearing motor with low energy
demand. • By the T timer. The built-in timer turns on the
fan in 60 seconds after closing of the external
• Maintenance-free bearings contain enough switch and allows the fan to operate from 2 to
grease for 40 000 hrs of non-stop operation. 30 minutes after opening of the external switch.
• Motor on special anti-vibration dampers When the interval timer is activated, the fan will
for vibration absorbing and silent operation. also turn on every 6, 12 or 24 hours depending
• Motor equipped with electric overheating on the selected interval and operate for the time
protection. specified by the turn-off delay timer (from 2 to
30 minutes).
Modifications and options • By the humidity sensor and the TH timer. If
the humidity level in the room exceeds the sensor
VENTS 100 Style T: equipped with threshold (60-90 %), the fan will automatically
a non-adjustable turn-on delay timer turn on and continue running for 2-30 minutes
(60 s), an adjustable turn-off delay timer (specified by the turn-off delay timer) after the
Innovative domestic extract (from 2 to 30 minutes), and an interval timer (from humidity returns to normal levels. When the fan is
fan with automatic shutters, 6 to 24 hours). turned on using the room light switch, it will turn
low-noise operation and low VENTS 100 Style TH: on with a time delay of 60 s, and after opening
equipped with a n
­ on-adjustable the switch it will continue to operate for the time
energy consumption specified by the turn-off delay timer (from 2 to 30
turn-on delay timer (60 s), an
with the capacity of up to 97 m3/h minutes).
adjustable turn-off delay timer (from 2 to 30 mi­­
nutes), and a humidity sensor adjustable from
Application 60 % to 90 %.
• Innovative extract fan with stylish design
for enhanced comfort level in shower rooms,
bathrooms, kitchens, and other residential
premises.
• Maximum air flow combined with low noise
level provide the ideal microclimate.
Design features
• Intermittent or continuous ventilation of
bathrooms, shower rooms, kitchens and other Aerodynamic mixed-flow
utility spaces. impeller
• Mounting into ventilation shafts or connection
to Ø 100 mm air ducts.

Design
• The casing and the impeller are made of high-
quality and durable UV-resistant plastic.

• Due to its modern look the fan is compatible


with any interior design.

• Specially designed impeller aerodynamic


profile provides high air flow and low noise.

• A shortened spigot for mounting into


a ventilation shaft or direct connection to
Ø 100 mm air ducts.

• The fan exhaust spigot incorporates specially Ventilation


unit
designed air rectifiers to reduce air turbulence,
noise level and boost air pressure.

• The removable ventilation unit enables easy


maintenance.
Casing with
• High ingress protection rating makes the controls
fan an ideal bathroom ventilation solution. The
electronic components are protected with tight Front panel
covers.

Accessories
Backdraft
Air ducts Grilles and hoods dampers Speed controllers Clamps

56 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Technical data

Power Maximum Sound


Frequency Voltage Current Weight
Model consumption RPM [min-1] air flow pressure level IP
[Hz] [V] [A] [kg]
[W] [m3/h] at 3 m [dBA]

VENTS 100 Style 50 220-240


9 0.059 2165 97 25 0.55 44
VENTS 100 Style
60 220
(220 V/60 Hz)

Aerodynamic characteristics Overall dimensions


Air flow [l/s]
Dimensions [mm]
0 5 10 15 20 25 Model
45
a b c Ød e
Static pressure [Pa]

40 VENTS 100 Style VENTS 100 Style 175 221 77 99 39

35 e
c
30

25

20

Ød
15

10

b
5

0
0 10 20 30 40 50 60 70 80 90 100
Air flow [m3/h] a

Mounting example

Certificates

The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 57


LOW-NOISE AND ENERGY-SAVING AXIAL FANS

VENTS Style • The integrated thermal actuator enables


smooth opening and closing of the front panel to
VENTS 100 Style Duo TH:
equipped with a non-adjusta-
Duo Series prevent backdrafting. ble turn-on delay timer (60 s),
an adjustable turn-off delay timer (from 2 to 30
minutes), and a humidity sensor adjustable from
60 % to 90 %.

Control
Manual:
• The fan is controlled by a room light switch (not
included in the delivery set).
Automatic:
• By the T timer. The built-in timer switches the
fan to high speed in 60 seconds after the external
switch closes and allows it to operate at high speed
for 2-30 minutes after the external switch opens.
Motor Then the fan returns to the previous operation mode.
When the interval timer is activated, the fan will also
• The motor is equipped with a new energy ef- turn on every 6, 12 or 24 hours depending on the se-
ficient two-speed ball bearing motor with low en- lected interval and operate at the first speed for the
ergy demand. time specified by the turn-off delay timer (from 2 to
Innovative two-speed
domestic extract fan • Maintenance-free bearings contain enough 30 minutes).
grease for 40 000 hrs of non-stop operation.
with automatic shutters, • By the humidity sensor and the TH timer. If the hu-
low-noise operation and • Motor on special anti-vibration dampers for vi- midity level in the room exceeds the sensor threshold
bration absorbing and silent operation. (60-90 %), the fan will automatically switch to high
low energy consumption speed and continue running from 2  to 30  minutes
with the capacity of up to 90 m3/h • Motor equipped with electric overheating pro-
(specified by the timer) after the humidity returns to
tection.
normal levels. When the fan is turned on using the
room light switch, it will turn on at low speed with
Modifications and options a time delay of 60 s, and after opening the switch it
Application
will continue to operate for the time specified by the
• Innovative extract fan with stylish design for VENTS 100 Style Duo T: equipped turn-off delay timer (from 2 to 30 minutes).
enhanced comfort level in shower rooms, bath- with a non-adjustable turn-on delay
rooms, kitchens, and other residential premises. timer (60 s), an adjustable turn-off delay
timer (from 2 to 30 minutes), and an interval timer
• Maximum air flow combined with low noise (from 6 to 24 hours).
level provide the ideal microclimate.
• Intermittent or continuous ventilation of bath-
rooms, shower rooms, kitchens and other utility
spaces.
• Mounting into ventilation shafts or connec-
tion to Ø 100 mm air ducts.

Design
• The casing and the impeller are made of high-
quality and durable UV-resistant plastic.
• Due to its modern look the fan is compatible
with any interior design.
• Specially designed impeller aerodynamic pro-
file provides high air flow and low noise.
• A shortened spigot for mounting into a venti-
lation shaft or direct connection to Ø 100 mm air
ducts.
• The fan exhaust spigot incorporates special-
ly designed air rectifiers to reduce air turbulence,
noise level and boost air pressure.
• High ingress protection rating makes the
fan an ideal bathroom ventilation solution. The
electronic components are protected with tight
­covers.

Accessories
Backdraft
Air ducts Grilles and hoods dampers Speed controllers Clamps

58 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Technical data

Power Maximum Sound


Voltage Current Weight
Model Speed consumption RPM [min-1] air flow pressure level IP
[V/50 Hz] [A] [kg]
[W] [m3/h] at 3 m [dBA]
min 6 0.039 1850 60 22
VENTS 100 Style Duo 220-240 0.55 44
max 8.5 0.063 2400 90 25

Design features

Aerodynamic
mixed-flow impeller

Ventilation
unit

Casing
with controls
Front panel

Aerodynamic characteristics Overall dimensions

Air flow [l/s]


Dimensions [mm]
0 5 10 15 20 25 Model
50 a b c Ød e
Static pressure [Pa]

VENTS 100 Style Duo 175 221 77 99 39


45 VENTS 100 Style Duo
40
e
c
35

30

25
max
Ød

20

15
min
b

10

0
0 10 20 30 40 50 60 70 80 90
a
Air flow [m3/h]

Certificates

The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 59


LOW-NOISE AND ENERGY-SAVING AXIAL FANS

Series • The fan is equipped with a specially designed Control


backdraft damper to prevent back flow and heat
VENTS Solid losses during the fan standby. Manual control:
• The fan exhaust spigot incorporates special- • Manual operation with a room light switch
ly designed air rectifiers to reduce air turbulence, (not included in the delivery set).
noise level and boost air pressure. • Operation with a built-in pull cord switch V.
Not applicable in case of the ceiling mounting.
Motor Automatic control:
• Reliable motor with low energy demand. • Control with the electronic control unit
• Rated for continuous operation and is com- BU-1-60 (see Electrical Accessories). The control
pletely maintenance-free. unit is supplied separately.
• Integrated overheating protection. • Control with the turn-off delay timer T. The
built-in turn-off delay timer enables operation of
the fan within 2 up to 30 minutes after turning the
Modifications and Options fan off with a switch.

Solid L: modification with a ball bearing • Control with the timer T1. After turning of the
external switch the turn-on delay timer is activat-
motor for long service life (around 40 000
ed for from 10 se­conds to 2 minutes. The fan re-
operating hours). Installation at any an-
mains turned off. After the fan is turned off with
gle is possible. The ball bearings require no main-
the external switch the fan keeps running within 2
tenance and are greased for the entire service life.
up to 30 minutes according to the settings of the
Solid T: modification with a regulated turn-off delay timer.
turn-off delay timer.
• Control with the timer and humidity sen-
Low-noise and low-power sor TH. If the indoor humidity exceeds the set hu-
extract axial fan with air flow Solid T1: modification with a turn-on midity point adjustable from 60 to 90 %, the fan
up to 85 m3/h delay timer regulated from 10 se­conds to switches automatically on and runs until the in-
2 minutes and a turn-off delay timer reg- door humidity drops below the set humidity
ulated from 2 up to 30 minutes. point. After that the fan continues running accord-
Application ing to the timer settings and turns off.
Solid TH: modification with a
• Permanent or intermittent extract ventilation turn-off delay timer regulated
of shower rooms, bathrooms, kitchens and other from 2 up to 30 minutes and a Mounting features
residential premises humidity sensor regulated from 60 % up to 90 %.
• Ventilation of premises with high requi­ Solid V: modification with a pull-cord
• Direct installation inside a ventilation shaft.
rements to noise level. switch. • Flexible air ducts may be used in case of re-
mote location of the ventilation shaft. The air duct
• Mounting into ventilation shafts or connec- is connected to the exhaust spigot with a fixing
tion to Ø 100 mm air ducts. clamp.
Solid VT: modification with a
pull-cord switch and a turn-off • Wall mounting with screws.
Design delay timer regulated from 2
up to 30 minutes. • Suitable for ceiling mounting.
• Modern design and aesthetic look.
Solid VTH: modi-
• The casing, the impeller and the front pa-
fication with a pull
nel are made of high-quality and durable UV-
cord switch, turn-
resistant plastic.
off delay timer regulated from 2 up to 30 mi-nutes
• The specially designed aerodynamic profile of and a humidity sensor regulated from 60 % up to
the mixed-flow impeller provides high air flow and 90 %.
pressure combined with low-noise operation.

Colour modifications

Solid Solid Red Solid Black Solid Dim Solid Glass Solid Solid Solid Alu Solid Chrome
Front panel Front panel Sapphire white matte front panel made Glass Red Glass Black front panel front panel with a
in white, in red Front panel front panel of white front panel made front pane made of with a stainless polished stainless
basic model in black natural glass of red natural glass black natural glass steel trim steel trim

Accessories
Backdraft
Air ducts Grilles and hoods dampers Speedcontrollers Clamps

60 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Aerodynamic characteristics
Air flow [l/s] Air flow [l/s]
0 3 6 9 12 15 18 21 24 0 5 10 15 20 25 30 35 40 45
45 55
Static pressure, ∆P [Pa]

Static pressure, ∆P [Pa]


50
40 VENTS 100 Solid VENTS 125 Solid
VENTS 100 Solid 12 45
35
40
30
35

25 30

20 25

20
15
15
10
10
5 5

0 0
0 10 20 30 40 50 60 70 80 90 0 20 40 60 80 100 120 140 160
Air flow [m3/h] Air flow [m3/h]

Overall dimensions
Dimensions [mm]
Model
ØD B L L1
VENTS 100 Solid 99.0 160 79 38
VENTS 125 Solid 123.5 180 85 38

Technical data

Power Maximum Sound


Frequency Voltage Current Weight
Model consumption RPM [min-1] air flow pressure Level IP
[Hz] [V] [A] [kg]
[W] [m3/h] at 3 m [dBA]
VENTS 100 Solid 50 220-240
VENTS 100 Solid 8 0.05 2000 85 27 0.51 44
60 220
(220 V/60 Hz)
VENTS 100 Solid 12 50 12 9 1.06 1950 80 26 0.51 44
VENTS 125 Solid 50 220-240
VENTS 125 Solid 18 0.11 2200 155 32 0.75 44
60 220
(220 V/60 Hz)

Mounting example

Certificates

IP44 The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 61


LOW-NOISE AND ENERGY-SAVING AXIAL FANS

Series Motor Control


VENTS Wave • Reliable motor with low energy demand. Manual control:
• Rated for continuous operation and is • Manual operation with a room light switch
completely maintenance-free. (not included in the delivery set).
• Integrated overheating protection • Operation with a built-in pull cord switch V.
Not applicable in case of the ceiling mounting.
Modifications and Options Automatic control:
Wave L: modification with a ball bearing • Control with the electronic control unit
motor for long service life (around BU-1-60 (see Electrical Accessories). The control
40  000 operating hours). Installation at unit is supplied separately.
any angle is possible. The ball bearings require • Control with the turn-off delay timer T. The
no maintenance and are greased for the entire built-in turn-off delay timer enables operation of
service life. the fan within 2 up to 30 minutes after turning the
Wave T: modification with a regulated fan off with a switch.
turn-off delay timer. • Control with the timer T1. After turning of
the external switch the turn-on delay timer is
activated for from 10 se­conds to 2 minutes. The fan
Wave T1: modification with a turn-on remains turned off. After the fan is turned off with
delay timer regulated from 10 se­conds the external switch the fan keeps running within 2
Low-noise and low-power to 2 minutes and a turn-off delay timer up to 30 minutes according to the settings of the
extract axial fan with regulated from 2 up to 30 minutes. turn-off delay timer.
air flow up to 85 m3/h Wave TH: modification
with a turn-off delay timer
• Control with the humidity sensor and timer
TH. If the indoor humidity exceeds the set
regulared from 2 up to 30 humidity point adjustable from 60 to 90  %, the
Application minutes and a humidity sensor regulated from fan switches automatically on and runs until the
60 % up to 90 %.
• Permanent or intermittent extract ventilation indoor humidity drops below the set humidity
of shower rooms, bathrooms, kitchens and other Wave V: modification with a pull-cord point. After that the fan continues running
residential premises switch. according to the timer settings and turns off.
• Ventilation of premises with high require-
ments to noise level. Wave VT: modification with a
• Mounting into ventilation shafts or connec- pull-cord switch and a turn-off
tion to Ø 100 mm air ducts. delay timer regulated from 2
up to 30 minutes.
Design Wave VTH: modi-
fication with a pull
• Modern design and aesthetic look. cord switch, turn-
• The casing, the impeller and the front pa- off delay timer regulated from 2 up to 30 mi-nutes
nel are made of high-quality and durable UV- and a humidity sensor regulated from 60 % up to
resistant plastic. 90 %.
• The specially designed aerodynamic profile of
the mixed-flow impeller provides high air flow and Mounting features
pressure combined with low-noise operation.
• Direct installation inside a ventilation shaft.
• The fan is equipped with a specially designed
• Flexible air ducts may be used in case of
backdraft damper to prevent back flow and heat
losses during the fan standby. remote location of the ventilation shaft. The air
duct is connected to the exhaust spigot with a
• The fan exhaust spigot incorporates specially fixing clamp.
designed air rectifiers to reduce air turbulence,
noise level and boost air pressure. • Wall mounting with screws.
• Suitable for ceiling mounting.

Accessories
Backdraft
Air ducts Grilles and hoods dampers Speed controllers Clamps

62 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Aerodynamic characteristics Overall dimensions
45 Dimensions [mm]
Static pressure, ∆P [Pa]

Model
40 VENTS 100 Wave ØD B L L1
VENTS 100 Wave 99 160 79 38
35

30

25

20

15

10

0
0 10 20 30 40 50 60 70 80 90
Air flow [m3/h]

Technical data
Power Maximum Sound
Frequency Voltage Current RPM Weight
Model consumption air flow pressure Level IP
[Hz] [V] [A] [min-1] [kg]
[W] [m3/h] at 3 m [dBA]

VENTS 100 Wave 50 220-240 8 0.05 2000 85 25 0.51 44


VENTS 100 Wave (220 V/60 Hz) 60 220 8 0.05 2000 85 25 0.51 44

Mounting example

Certificates

IP44 The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 63


LOW-NOISE AND ENERGY-SAVING AXIAL FANS

Series Modifications and Options Control


VENTS Flip Flip L: modification with a ball bear- Manual control:
ing motor for long service life (around
40  000 operating hours). Installation at
• Manual operation with a room light switch
(not included in the delivery set).
any angle is possible. The ball bearings require no
maintenance and are greased for the entire ser- • Operation with a built-in pull cord switch V.
vice life. Not applicable in case of the ceiling mounting.

Flip T: modification with a regulated Automatic control:


turn-off delay timer. • Control with the electronic control unit
BU-1-60 (see Electrical Accessories). The control
unit is supplied separately.
Flip T1: modification with a turn-on
delay timer regulated from 10 se­conds • Control with the turn-off delay timer T. The
to 2 minutes and a turn-off delay timer built-in turn-off delay timer enables operation of
regulated from 2 up to 30 minutes. the fan within 2 up to 30 minutes after turning the
fan off with a switch.
Flip TH: modification with a
turn-off delay timer regulated • Control with the timer T1. After turning of the
from 2 up to 30 minutes and a external switch the turn-on delay timer is activat-
humidity sensor regulated from 60 % up to 90 %. ed for from 10 se­conds to 2 minutes. The fan re-
Low-noise and low-power mains turned off. After the fan is turned off with
Flip V: modification with a pull-cord the external switch the fan keeps running within 2
extract axial fan with air flow switch. up to 30 minutes according to the settings of the
up to 85 m3/h turn-off delay timer.
Flip VT: modification with a • Control with the timer and humidity sen-
pull-cord switch and a turn-off sor TH. If the indoor humidity exceeds the set hu-
Application delay timer regulated from 2 midity point adjustable from 60 to 90 %, the fan
up to 30 minutes. switches automatically on and runs until the in-
• Permanent or intermittent extract ventilation door humidity drops below the set humidity
of shower rooms, bathrooms, kitchens and other Flip VTH: modifi-
residential premises. cation with a pull point. After that the fan continues running accord-
cord switch, turn- ing to the timer settings and turns off.
• Ventilation of premises with high require-
off delay timer regulated from 2 up to 30 mi-
ments to noise level.
nutes and a humidity sensor regulated from 60 %
• Mounting into ventilation shafts or connec- up to 90 %.
tion to Ø 100 mm air ducts.
Mounting features
Design
• Direct installation inside a ventilation shaft.
• Modern design and aesthetic look.
• Flexible air ducts may be used in case of remote
• The casing, the impeller and the front pa- location of the ventilation shaft. The air duct is con-
nel are made of high-quality and durable UV-re- nected to the exhaust spigot with a fixing clamp.
sistant plastic.
• Wall mounting with screws.
• The specially designed aerodynamic profile of
• Suitable for ceiling mounting.
the mixed-flow impeller provides high air flow and
pressure combined with low-noise operation.
• The fan is equipped with a specially designed
backdraft damper to prevent back flow and heat
losses during the fan standby.
• The fan exhaust spigot incorporates special-
ly designed air rectifiers to reduce air turbulence,
noise level and boost air pressure.

Motor
• Reliable motor with low energy demand.
• Rated for continuous operation and is com-
pletely maintenance-free.
• Integrated overheating protection.

Accessories
Backdraft
Air ducts Grilles and hoods dampers Speed controllers Clamps

64 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Aerodynamic characteristics Overall dimensions
45 Dimensions [mm]
Static pressure, ∆P [Pa]

Model
40 VENTS 100 Flip ØD B L L1

35 VENTS 100 Flip 99 160 79 38

30

25

20

15

10

0
0 10 20 30 40 50 60 70 80 90
Air flow [m3/h]

Technical data

Power Maximum Sound


Frequency Voltage Current RPM Weight
Model consumption air flow pressure level IP
[Hz] [V] [A] [min-1] [kg]
[W] [m3/h] at 3 m [dBA]

VENTS 100 Flip 50 220-240 8 0.05 2000 85 25 0.51 44


VENTS 100 Flip (220 V/60 Hz) 60 220 8 0.05 2000 85 25 0.51 44

Mounting example

Certificates

IP44 The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 65


LOW-NOISE AND ENERGY-SAVING AXIAL FANS

VENTS MF Motor Control


Manual control:
Series • Low energy demand from 8 W due to new
high-efficient motor. • Manual control with a room light switch. The
switch is not included into delivery set.
• Protection rating IP 44.
• Designed for continuous operation and • The fan is controlled by the built-in pull cord
requires no maintenance. switch V. Not applied in case of ceiling mounting.

• Motor equipped with overheating protection. • Speed control is possible through a thyristor\
speed controller (see Electrical Accessories). Several
fans may connected to the same controller. Speed
Modifications and Options controllers can not be connected to the fans with T,
TH, TP, VT, VTH modification.
MF L – the motor is equipped with ball
bearings for long service life (appr. 40 Automatic:
thousand hours) and fan mounting at • By the electronic control unit BU-1-60. The
any angle. The bearings are maintenance-free and control unit is supplied separately.
contain enough grease for the entire operating
period.
• By the timer T (the built-in run-out timer enables
the fan operation within 2 to 30 minutes after the fan
MF T – off-delay timer modification switching off).
with operating time from 2 to 30 min.
• By the humidity sensor and timer TH (if the
humidity level in the room exceeds the sensor
Low-noise and energ saving threshold adjustable value within 60-90% the fan
MF T1 – modification with turn-on
axial fan for exhaust ventilation delay timer (adjustable from 0 to 2 switches automatically on and operates until the
with air capacity up to 255 m3/h humidity level drops to the standard level, after
minutes) and off-delay timer (adjustable
that the fan continues operating within the time
from 2 to 30 minutes).
period according to the timer setting, then shuts
Applications MF TH – off-delay timer down).
modification with the
• Continuous or periodic exhaust ventilation
operating time from 2 to 30
of bathroom, showers, kitchens and other utility Mounting features
spaces. min and humidity sensor with threshold from 60
to 90%. • The fan is mounted directly into the ventilation
• Ventilation of premises with high noise level
MF V – pull-cord switch modification.
shaft.
limitations. • Flexible duct application is recommended in
• Mounting into ventilation shafts or connection case of remote location of the ventilation shaft.
to Ø100, 125 and 150 mm air ducts. • The air duct is connected to the fan exhaust
MF VT – modification with flange through a clamp.
Design pull-cord switch and off-delay
timer with operating time
• Fixed to wall by self-tapping screws.

• The casing and the impeller are made of high- from 2 to 30 min. • Suitable for ceiling mounting.
quality durable ABS plastic, UV resistant.
MF VTH – modi-
• Specially designed impeller aerodynamic fication with pull-
profile provides high air capacity and low noise. cord switch, off-
• The fan is equipped with a back valve to delay timer with operating time from 2 to 30 min
prevent back flow and heat losses during the fan and humidity sensor with threshold from 60 to
standby. 90%.
• The fan exhaust spigot incorporates specially
designed air rectifiers to reduce air turbulence,
increase air pressure and lower noise level.

Accessories
Backdraft
Air ducts Grilles and hoods damper Speed controllers Clamps

66 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Aerodynamic characteristics
Air capacity [l/s] Air capacity [l/s] Air capacity [l/s]
0 5 10 15 20 25 0 5 10 15 20 25 30 35 40 45 50 0 10 20 30 40 50 60 70
45 70 70
Pressure ∆P [Pa]

Pressure ∆P [Pa]

Pressure ∆P [Pa]
40
VENTS 100 MF VENTS 125 MF VENTS 150 MF
VENTS 100 MF 12 60 60
35
50 50
30

25 40 40

20 30 30
15
20 20
10
10 10
5

0 0 0
0 10 20 30 40 50 60 70 80 90 100 0 20 40 60 80 100 120 140 160 180 0 40 80 120 160 200 240 280
Air capacity [m3/ h] Air capacity [m3/ h] Air capacity [m3/ h]

Technical data
Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]
VENTS 100 MF 50
VENTS 100 MF 220-240 8 0.05 2165 90 29 0.45
60
(220 V/60 Hz)
VENTS 100 MF 12 50 12 8 1.02 2075 85 28 0.45
VENTS 125 MF 50
VENTS 125 MF 220-240 18 0.11 2200 160 34 0.80
60
(220 V/60 Hz)
VENTS 150 MF 230 220-240 28 0.21 1545 255 35 0.97

Overall dimensions
Dimensions [mm]
Model
ØD B L L1
VENTS 100 MF 99 150 79 19
VENTS 125 MF 124 180 85 21
VENTS 150 MF 148 205 112 23

Mounting example

Certificates

The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 67


LOW-NOISE AND ENERGY-SAVING AXIAL FANS

Series Motor Mounting features


VENTS MF Duo • Low energy demand from 5 W due to a new two- • The fan is mounted directly into the ventilation
speed high-efficient motor. shaft.

• Ingress protection rating IP44. • Flexible duct connection is recommended in


case of the remote ventilation shaft location. The air
• Designed for continuous operation and requires duct is connected to the fan exhaust flange through
no maintenance. a clamp.
• Equipped with overheating protection. • Wall fixing with screws.
• Suitable for ceiling mounting.
Modifications and options
MF L Duo – the motor is equipped with
ball bearings to increase the service life
(about 40 thousand operating hours) and
fan mounting at any angle. The bearings are mainte-
nance-free and contain enough grease for the entire
operating period.
MF T1 Duo – equipped with an adjustable
high-speed turn-on delay timer (from 0 to
2 minutes) and an adjustable high-speed
Two-speed axial low-noise and low turn-off delay timer (from 2 to 30 minutes).
energy fans for exhaust ventilation MF TH Duo – equipped with an
with air flow up to 300 m3/h adjustable turn-off delay tim-
er (from 2 to 30 minutes) and a
fixed turn-on delay timer (45 s) with a humidity sen-
Application sor adjustable from 60 % to 90 %.

• Continuous or periodic exhaust ventilation of Control


bathroom, showers, kitchens, and other residential
Manual:
premises.
• Ventilation of premises with high requirements
• The fan is operated via a light switch (not includ-
ed in the delivery set).
to noise level.
Automatic:
• Permanent low-speed operation mode ensures
continuous air exchange in the room. • By the T1 timer. When the external switch is
turned on, the fan switches to a higher speed with
• Ventilation shaft mounting or connection to a delay of 0 to 2 minutes. When the external switch
Ø 100, 125 and 150 mm air ducts. is turned off, the fan will return to a low speed with a
delay of 2 to 30 minutes.
Design • By the humidity sensor and the TH timer. If
• The casing and the impeller are made of high- the humidity level in the room exceeds the sensor
threshold (60-90 %), the fan will automatically switch
quality durable plastic, UV resistant.
to a higher speed and will continue running until
• The aerodynamic design of the impeller ensures humidity returns to normal levels. Then the fan runs
high air flow and low noise level. for 5 minutes at a high speed and switches to a low
• The fan is equipped with a specially designed speed. The fan with a timer and TH humidity sensor
backdraft damper to prevent back flow and heat can also be controlled in manual mode, for example,
losses during the fan standby. using the light switch. When the control vol­­tage is
applied, the turn-on delay timer is activa­ted for 45 se­­
• The fan outlet spigot incorporates specially de-
conds and the fan switches to the se­­cond speed.
signed air rectifiers to reduce air turbulence, noise
After disconnecting the control voltage, the fan runs
level and increase air pressure.
for a time set by the turn-off delay timer (from 2 to 30
minutes), and switches to the first speed.

Accessories
Backdraft
Air ducts Grilles and hoods damper Speed controllers Clamps

68 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Aerodynamic characteristics
55 45 100
Pressure, ΔP [Pa]

Pressure, ΔP [Pa]

Pressure, ΔP [Pa]
50 VENTS 100 MF Duo 40 VENTS 125 MF Duo 90 VENTS 150 MF Duo
45 80
35
40
70
30
35
60
30 25
max 50
25 max
20
max
min 40
20
15
30
15
min 10 min
20
10
5 10
5

0 0 0
0 10 20 30 40 50 60 70 80 90 0 25 50 75 100 125 150 175 0 50 100 150 200 250 300
Air flow [m3/ h] Air flow [m3/ h] Air flow [m3/ h]

Technical data

Frequency Voltage Power Current Maximum air Sound pressure level Weight
Model Speed RPM [min-1] IP Code
[Hz] [V] [W] [A] flow [m3/h] at 3 m distance [dBA] [kg]

VENTS min. 5 0.030 54 1800 23


50 220-240 0.55 IP44
100 MF Duo max. 8 0.050 81 2100 28
VENTS min. 10 0.068 130 1100 29
50 220-240 0.78 IP44
125 MF Duo max. 14 0.092 160 1800 33
VENTS min. 18 0.079 210 1520 29
50 220-240 0.97 IP44
150 MF Duo max. 21 0.085 300 2050 35

Overall dimensions
Dimensions [mm]
Model
ØD B L L1
VENTS 100 MF Duo 99 150 79 19
VENTS 125 MF Duo 124 180 85 21
VENTS 150 MF Duo 148 205 112 23

Application example

Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 69


LOW-NOISE AND ENERGY-SAVING AXIAL FANS

VENTS Casto Motor Control


Series • Low energy demand from 8 W due to new Manual control:
high-efficient motor. • Manual control by a room light switch. The
switch is not included into the delivery set.
• Designed for continuous operation and
requires no maintenance. • The fan is controlled by the built-in pull cord
switch V. Not applied in case of ceiling mounting.
• Motor equipped with overheating protection.
• Speed control is possible through a thyristor
speed controller (see Electrical Accessories). Speed
Modifications and Options controllers can not be connected to the fans with T,
Casto L – the motor is equipped with TH, TP, VT, VTH modification.
ball bearings for long service life (appr. Automatic:
40 thousand hours) and fan mounting at
any angle. The bearings are maintenance-free and • By the electronic control unit BU-1-60 (see
Electrical Accessories). The control unit is supplied
contain enough grease for the entire operating separately.
period.
Casto T – an adjustable turn-off delay
• By the timer T (the built-in adjustable turn-off
delay timer enables the fan to operate within 2 to 30
timer modification with operating time minutes after the fan switching off).
from 2 to 30 min.
Casto T1 – modification with a turn-
• By the timer T1 (the built-in adjustable turn-
on and turn-off delay timer turns on the fan in
Low-noise and energy saving on delay timer (adjustable from 0 to 0…2 min after the switch provides a control signal
axial fan for exhaust ventilation 2 minutes) and a turn-off delay timer and allows it to operate from 2 to 30 minutes after
with air flow up to 255 m3/h (adjustable from 2 to 30 minutes). opening of the switch).
Casto TH – an adjustable • By a humidity sensor and timer TH (if the
timer modification with the humidity level in the room exceeds the sensor
Application operating time from 2 to 30 threshold adjustable value within 60-90% the fan
• Continuous or periodic exhaust ventilation min and a humidity sensor with threshold from switches automatically on and operates until the
of bathroom, showers, kitchens and other utility 60 to 90%. humidity level drops to the standard level, after
spaces. Casto V – a pull-cord switch modifi­ca­ that the fan continues operating within the time
• Ventilation of premises with high noise level tion. period according to the timer setting, then shuts
limitations. down).
• Mounting into ventilation shafts or connection Mounting features
to Ø100 and 150 mm air ducts.
Casto VT – modification
with a pull-cord switch and
• The fan is mounted directly into the ventilation
shaft.
Design an adjustable timer with
operating time from 2 to 30 min. • Flexible duct application is recommended in
• The casing and the impeller are made of high- case of remote location of the ventilation shaft.
quality durable ABS plastic, UV resistant. Casto VTH – modi-
fication with a pull- • The air duct is connected to the fan exhaust
• Specially designed impeller aerodynamic
cord switch, an
flange through a clamp.
profile provides high air flow and low noise.
adjustable timer with operating time from 2 to 30 • Fixed to the wall by self-tapping screws.
• The fan is equipped with a back valve to min and a humidity sensor with threshold from • Can be ceiling mounted in case the fan is
prevent back flow and heat losses during the fan 60 to 90%. ordered with ball bearings (Casto L modification).
standby.
• The fan exhaust spigot incorporates specially
designed air rectifiers to reduce air turbulence,
increase air pressure and lower noise level.

Accessories
Backdraft Speed
Air ducts Grilles and hoods damper controller Clamps

70 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Aerodynamic characteristics
Air flow [l/s] Air flow [l/s]
25 00 5 5 10 1510 20 15
25 30 20 35 4025 45 50 0 05 10
10 15
20 2030 25 40 30 5035 40 45
60 70 50 0 10 20 30 40 50 60 70
45
70 70 70 70
Pressure ∆P [Pa]

Pressure ∆P [Pa]
VENTS Casto 100 VENTS Casto 150
40
60 VENTS Casto 100-12 60 60 60
35
50 50 50 50
30

40
25 40 40 40

20
30 30 30 30
15
20 20 20 20
10
10 10 10 10
5

00 0 0 0
80 90 100 00 1020 20 4030 6040 80
50 60
100 70
120 8014090 160 100 180 0 0 20 40
40 60
80 80
120 100160120 200140 240 160 180
280 0 40 80 120 160 200 240 280
Air flow [m3/ h] Air flow [m3/ h]

Technical data

Power Maximum Specific Sound Pressure


Model Frequency Voltage Current Weight IP
Consumption Air Flow Power Level at 3 m

[Hz] [V] [W] [A] [m3/h] [l/s] [W/l/s] [dBA] [kg]


VENTS Casto 100 50 220-240
VENTS Casto 100 8 0.05 90 25 0.32 29 0.45 IP44
60 220
(220 V/60 Hz)
VENTS Casto 100-12 50 12 8 1.02 85 24 0.34 28 0.45 IP44
VENTS Casto 150 50 220-240 28 0.21 255 71 0.39 35 0.97 IP44

Overall dimensions

Dimensions [mm]
Model
ØD B L L1
VENTS Casto 100 99 150 79 23
VENTS Casto 150 148 206 112 23

Mounting example

Certificates

The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 71


LOW-NOISE AND ENERGY-SAVING AXIAL FANS

Series Motor Mounting features


VENTS Casto Duo • Low energy demand from 5 W due to a new two- • The fan is mounted directly into the ventilation
speed high-efficient motor. shaft.

• Designed for continuous operation and requires • Flexible duct connection is recommended in
no maintenance. case of the remote ventilation shaft location. The
air duct is connected to the fan exhaust flange by
• Equipped with overheating protection. means of a clamp.
• Wall fixing with screws.
Modifications and options
• Suitable for ceiling mounting.
Casto L Duo – the motor is equipped
with ball bearings to increase the ser-
vice life (about 40000 of operating hours)
and a fan, mounting at any angle. The bearings are
maintenance-free and contain enough grease for
the entire operating period.
Casto T1 Duo – equipped with an adjust-
able high-speed turn-on delay timer (from
0 to 2 minutes) and an adjustable high-
speed turn-off delay timer (from 2 to 30 minutes).
Two-speed axial low-noise and low Casto TH Duo – equipped with
energy fans for exhaust ventilation an adjustable turn-off delay tim-
with air flow up to 300 m3/h er (from 2 to 30 minutes) and a
fixed turn-on delay timer (45 s) with a humidity sen-
sor adjustable from 60 % to 90 %.
Application
Control
• Continuous or periodic exhaust ventilation of Manual:
bathroom, showers, kitchens, and other residential
premises.
• The fan is operated via light switch (not included
in the delivery set).
• Ventilation of premises with high requirements
Automatic:
to noise level.
• Permanent low-speed operation mode ensures
• By the T1 timer. When the external switch is
turned on, the fan switches to a higher speed with
continuous air exchange in the room.
a delay of 0 to 2 minutes. When the external switch
• Ventilation shaft mounting or connection to is turned off, the fan will return to a low speed with a
Ø 100 and 150 mm air ducts. delay of 2 to 30 minutes.
• By a humidity sensor and the TH timer. If the
Design humidity level in the room exceeds the sensor
threshold (60-90 %), the fan will automatically switch
• The casing and the impeller are made of high- to a higher speed and will continue running until
quality durable plastic, UV resistant. humidity returns to normal levels. Then the fan runs
• The aerodynamic design of the impeller ensures for 5 minutes at a high speed and switches to a low
high air flow and low noise level. speed. The fan with the TH timer and a humidity
sensor can also be controlled in manual mode, for
• The fan is equipped with a specially designed
example, using the light switch. When the control
backdraft damper to prevent back flow and heat
vol­­tage is applied, the turn-on delay timer is activa­
losses during the fan standby.
ted for 45  se­­conds and the fan switches to the se­­
• The fan outlet spigot incorporates specially de- cond speed. After disconnecting the control voltage,
signed air rectifiers to reduce air turbulence, noise the fan runs for a time set by the turn-off delay timer
level and increase air pressure. (from 2 to 30 minutes), and switches to the first
speed.

Accessories
Backdraft
Air ducts Grilles and hoods dampers Clamps

72 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Aerodynamic characteristics
Air flow [l/s] Air flow [l/s]
0 5 10 15 20 25 0 10 20 30 40 50 60 70 80
55 100
Pressure, ΔP [Pa]

Pressure, ΔP [Pa]
50
VENTS Casto 100-Duo VENTS Casto 150-Duo
90

45 80
40
70
35
60
30
50
25 max
max 40
20
30
15
min min
20
10

5 10

0 0
0 10 20 30 40 50 60 70 80 90 0 50 100 150 200 250 300
Air flow [m3/h] Air flow [m3/h]

Technical data

Power Maximum Specific Sound Pressure


Model Speed Frequency Voltage Current Weight IP
Consumption Air Flow Power Level at 3 m

[Hz] [V] [W] [A] [m3/h] [l/s] [W/l/s] [dBA] [kg]


min. 5 0.030 54 15 0.33 23
VENTS Casto 100-Duo 50 220-240 0.55 IP44
max. 8 0.050 81 23 0.35 28
min. 18 0.079 210 58 0.31 29
VENTS Casto 150-Duo 50 220-240 0.97 IP44
max. 21 0.085 300 83 0.25 35

Overall dimensions
Dimensions [mm]
Model
ØD B L L1
VENTS Casto 100-Duo 99 150 79 23
VENTS Casto 150-Duo 148 206 112 23

Application example

Certificates
The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 73


AXIAL INLINE FANS

 VENTS Quietline Series

Axial inline fans, for exhaust or supply ventilation with the capacity up to 375 m3/h. Compatible
with Ø 100, 125 and 150 mm air ducts.

 VENTS VKO and VKOk Series

Axial inline fans, for exhaust or supply ventilation with the capacity up to 358 m3/h. Compatible
with Ø 100, 125 and 150 mm air ducts.

 VENTS VKO1 and VKO1k Series

Axial inline fans, for exhaust or supply ventilation with the capacity up to 365 m3/h. Compatible
with Ø 100, 125 and 150 mm air ducts.

74 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Axial inline fans
VENTS Quietline Series page
Air flow up to 375 m3/h 76

Axial inline fans


VENTS VKO Series page
Air flow up to 358 m /h
3
80

Axial inline fans with a fixing bracket


VENTS VKOk Series page
Air flow up to 358 m /h
3
80

Axial inline fans


VENTS VKO1 Series page
Air flow up to 365 m /h
3
82

Axial inline fans with a fixing bracket


VENTS VKO1k Series page
Air flow up to 365 m /h
3
82

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 75


AXIAL INLINE FANS

VENTS Quietline Modifications and Options Control


Manual speed control:
Series Quietline Extra: modification with a
two speed high-powered motor. • The fan is controlled by a room light switch. It
is not included in the delivery package.
Quietline Duo: modification with a • Speed control is performed with SRS-1
reliable single-phase two speed motor. thyristor speed controller (applicable for the
models without timer). Optionally, speed control
Quietline Q: modification with a low- for VENTS Quietline 100 Duo, VENTS Quietline 125
speed motor for quiet operation. Duo, VENTS Quietline 150 Duo, VENTS Quietline
150 Extra may be performed with P2-1-300 speed
Quietline 12: modification with a low switch (for details, see Electrical Accessories).
voltage 12V AC motor. Automatic speed control:

Quietline K: modification with a • With BU-1-60 electronic control unit (for


details, see Electrical Accessories). Available upon
backdraft damper for back flow
separate order.
prevention.
Quietline T: modification with a
• With timer T (integrated turn-off delay timer
keeps the fan operating 2 up to 30 minutes after
regulated timer with the operating time turning the fan off ).
adjustable from 2 to 30 minutes.
Quietline R: modification with a power cord Mounting features
Brand new low-noise axial inline fans, and IEC C14 electric plug.
• The fan is mounted into a matching duct size.
for exhaust or supply ventilation Quietline-k: modification with a fixing bracket Fastening with clamps in case of flexible duct
with superior capacity connection.
for flat surface mounting.
up to 375 m3/h • The mounting bracket enables fan installation
Operation modes of fans with on both horizontal and vertical flat surfaces
(Quietline-k model).
Application timer
• Serial mounting of two fans boosts the
• Innovative stylish extract or supply fans for Operation modes for T modifications of VENTS operation pressure.
enhanced comfort level. Quietline 100, VENTS Quietline 125, VENTS
Quietline 150 and VENTS Quietline 150 Extra • For 12 V low-voltage motor fan connection
• Continuous or periodic ventilation of
models are selected by setting the DIP switch in
to 220 V/50 Hz power mains use the step-down
bathroom, showers, kitchens and other utility transformer TRF 220/12-25 (available upon
spaces. required position.
separate order).
• Maximum air flow combined with low noise Mode 1
level ensures an ideal room microclimate. • The fan is turned off by default. The fan starts
• Exhaust or supply ventilation depending on operating at the low speed when the switch is
fan installation in the system. closed.
• Designed for plastic (flexible) ducts. Mode 2
• Transportation of low and medium air flow • The fan is turned off by default. The fan starts
volumes for small distances at low air resistance in operating at the high speed when the switch is
the ventilation system. closed.
• Compatible with Ø 100, 125 and 150 mm air Mode 3 (two-speed mode)
ducts.
• The fan operates at the low speed by default.
The fan switches to the high speed when the
Motor switch is closed.
• Reliable ball bearing motor with low energy
Mode 4 (automatic interval mode)
demand from 4.5 W.
• VENTS Quietline models are equipped • The fan operates at the low speed by default.
with a single-phase single or two speed motor The fan switches to the high speed each set
(Quietline Duo and Quietline Extra modifica- time period (adjustable from 1 to 15 hours) and
tions). operates up to 30 min to ventilate the premise
with maximum capacity. After that the fan models
• The integrated thermal overheating protec-
back to the continuous operation at low speed.
tion prevents motor overload.
• The motor rests on rubber anti-vibration con-
nectors to ensure low-noise operation of the fan
(except for VENTS Quietline 150 Q).

Accessories

Diffusers and air disk valves Air ducts Grilles and hoods Backdraft Speed controllers Control unit
damper

76 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Design
• The casing and the impeller are made of high-quality durable plastic.
• The exhaust spigot is fitted with specially designed air flow rectifiers to reduce air turbulence, noise level and increase air pressure.

• The impeller design enhances fan efficiency and ensures low-noise operation of the fan.
• Ingress protection rating IPX4.

Overall Dimensions [mm]

Model L ØD k

VENTS Quietline 100 137.5 99 -


VENTS Quietline-k 100 137.5 99 54
VENTS Quietline 125 161.5 125 -
VENTS Quietline-k 125 161.5 125 53.5
VENTS Quietline 150 182 150 -
VENTS Quietline-k 150 182 150 54

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 77


AXIAL INLINE FANS

Aerodynamic characteristics
60 60 60

VENTS Quietline 100 VENTS Quietline 100 Duo VENTS Quietline 100 12

50 50 50

40 40 40

30 30 30
max

20 20 20

min
10 10 10

0 0 0
0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100
Air flow Air flow Air flow

80
80 8080 120 80

VENTS
VENTSQuietline
Quietline125
125 VENTS
VENTSQuietline125
Quietline125Duo
Duo VENTS Quietline 150
70
70 7070 70
100

60
60 6060 60

80
50
50 5050 50

40
40 4040 60 40
max
max
30
30 3030 30
min
min 40

20
20 2020 20

20
10
10 1010 10

00 00 0 0
00 50
50 100
100 150
150 200
200 00 5050 100
100 150
150 200
200 0 50 100 150 200 250 300 350 0 50
Air
Airflow
flow AirAir
flow
flow Air flow

8080 80 120
120
120 140
140
140

uietline
150150
tline150
ine VENTS
VENTS
VENTS Quietline
Quietline
Quietline 150QQ
150 VENTS Quietline
VENTSQuietline 150
Quietline150 Duo
150Duo
Duo VENTS Quietline
Quietline
VENTS 150
150
Quietline Extra
Extra
150 Extra
7070 70 120
120
120
100
100
100

6060 60
100
100
100
8080
80
5050 50
8080
80
4040 40 6060
60
max
max
max max
max
max
6060
60
3030 30
4040
40
4040
40
2020 20
min
min
2020
20 min
min
min
2020
20
1010 10

00 0 00 0 00 0
250300
300300350
350350 00 0 50 50 100
50 100100 150
150150 200
200200 250
250
250 300
300 350
350 00 0 50
50
50 100
100
100 150
150
150 200
200 250
250
250 300
300
300 350
350
350 00 0 5050 100 150150 200
100 200200 250
250250 300
300300 350
350350 400
400400
AirAir Air flow
flow
flow AirAir flow
flow Air
Air flow
Airflow
flow Air
Airflow
flow
Air flow

78 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Technical data

Power Sound Pressure


Frequency Voltage Current Maximum air Weight
Model Speed consumption r.p.m. Level at
[Hz] [V] [A] flow [m3/h] [kg]
[W] 3 m [dBA]

VENTS Quietline 100 50 220-240


- 7.5 0.049 2100 100 25
VENTS Quietline 100 [220 V/60 Hz] 60 220
min. 4.5 0.029 1650 75 22
VENTS Quietline 100 Duo 50 220-240
max. 7.5 0.049 2100 100 25
0.61
VENTS Quietline 100 Duo min. 4.5 0.029 1650 75 22
60 220
[220 V/60 Hz] max. 7.5 0.049 2100 100 25

VENTS Quietline 100 12 - 50 12 7.5 0.99 2100 100 25

Vents Quietline 125 50 220-240


- 13 0.085 2250 197 32
Vents Quietline 125 [220 V/60 Hz] 60 220
min. 10 0.065 1950 145 29
Vents Quiteline 125 Duo 50 220-240 0.75
max. 13 0.085 2250 197 32
Vents Quiteline 125 Duo min. 10 0.065 1950 145 29
60 220
[220 V/60 Hz] max. 13 0.085 2250 197 32
VENTS Quietline 150 50 220-240
- 22 0.095 2250 335 39
VENTS Quietline 150 [220 V/60 Hz] 60 220
VENTS Quietline 150 Q 50
- 220-240 26 0.085 1900 305 37
VENTS Quietline 150 Q [220 V/60 Hz] 60 1.3
min. 19 0.087 1950 250 36
VENTS Quietline 150 Duo 50/60 220-240
max. 22 0.095 2250 335 39
min. 22 0.103 2300 285 36
VENTS Quietline 150 Extra 50/60 220-240
max. 25 0.109 2600 375 41

Mounting examples

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 79


AXIAL INLINE FANS

VENTS VKO Design Control


Series • The casing and the impeller are made of high- Manual:
quality durable ABS plastic, UV resistant. • The fan is controlled by a room light switch. It
is not included in the delivery package.
• The intellectual impeller design makes the fan
efficiency high and the service life long. • Speed control is possible through a thyristor
speed controller (see Electrical Accessories).
• Protection rating IPX4.
Several fans may connected to the same controller.
Speed controllers can not be connected to the
Motor fans with T, TH, TP, VT, VTH modification.
• Reliable and low-watt electric motor. Automatic:
• Designed for continuous operation and • By the electronic control unit BU-1-60 (see
requires no maintenance. Electrical Accessories). The control unit is supplied
separately.
• Equipped with overheating protection.

Modifications and Options Mounting features


VKOk – fan with a fixing bracket for flat surface • The fan is mounted into a matching duct size.
mounting. Fastening with clamps in case of flexible duct
connection.
VKO L – the motor is equipped with ball
Axial inline fans, bearings for long service life (appr. 40 • This series fans have different intake and
for exhaust or supply ventilation with thousand hours) and fan mounting at exhaust flange diameters to enable attachment of
the capacity up to 358 m3/h any angle. The bearings are maintenance-free and the decorative grille MV to the appropriate intake
contain enough grease for the entire operating flange diameter in case of direct installation into
period. the ventilation shaft or instead of the existing
ventilation grille.
Application VKO turbo – high-powered motor.
• The fan can be mounted on a horizontal or
• Continuous or periodic exhaust ventilation vertical flat surface by a fixing bracket (VKOk
of bathroom, showers, kitchens and other utility model).
spaces. VKO press – 5-blade low-noise impeller
• Two fans can be installed in series for higher
• Exhaust or supply ventilation depending on with improved aerodynamics for higher performance.
the fan mounting type in the system. fan capacity.
• For 12 V low-voltage motor fan connection
• Designed for PVC ducting systems or flexible VKO 12 – modification with low- to 220 V/50 Hz power mains use the step-down
ducts. voltage motor. 12 V AC power supply. transformer TRF 220/12-25 that is available upon
• Low to medium air flow motion for short dis- separate order.
tances at low air resistance.
• Compatible with Ø 100, 125 and 150 mm air
ducts.

Mounting examples
VKOk fan cottage
ventilation example

VKO fan flat ventilation


example

Accessories
Backdraft
Diffusers and air disk valves Air ducts Grilles and hoods damper Speed controllers Clamps

80 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Aerodynamic characteristics

Air flow [m3/h] Air flow [m3/h] Air flow [m3/h]

Technical data

Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consump- R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
tion [W]

VENTS 100 VKO 50/60 220-240 14 0.085 2300 105 37 0.41


VENTS 100 VKO turbo 50/60 220-240 16 0.1 2300 135 38 0.41
VENTS 100 VKO press 50/60 220-240 16 0.1 2300 106 39 0.41
VENTS 100 VKO 12 50/60 12 14 1.5 2200 92 36 0.40
VENTS 125 VKO 50/60 220-240 16 0.1 2400 185 38 0.48
VENTS 125 VKO turbo 50/60 220-240 24 0.105 2400 243 39 0.48
VENTS 125 VKO press 50/60 220-240 24 0.105 2400 192 39 0.48
VENTS 125 VKO 12 50/60 12 16 1.33 2300 165 37 0.46
VENTS 150 VKO 50 220-240
VENTS 150 VKO 24 0.13 2400 298 40 0.80
60 220
(220 V/60Hz)
VENTS 150 VKO turbo 50 220-240
VENTS 150 VKO turbo 29 0.13 2400 358 44 0.80
60 220
(220 V/60 Hz)
VENTS 150 VKO press 50 220-240
VENTS 150 VKO press 29 0.13 2400 312 44 0.80
60 220
(220 V/60 Hz)

VENTS 150 VKO 12 50 12 29 2 2300 266 39 0.76

Overall dimensions

Dimensions [mm]
Model
Ø D Ø D1 B B1 H L L1 L2 L3
VENTS 100 VKO 100 104 – – – 91 31 – –
VENTS 100 VKOk 100 104 160 144 114 91 31 45 29
VENTS 125 VKO 125 129 – – – 93 31 – –
VENTS 125 VKOk 125 129 185 169 139 93 31 45 29
VENTS 150 VKO 150 154 – – – 108 46 – –
VENTS 150 VKOk 150 154 200 184 163 108 46 45 29

Certificates

The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 81


AXIAL INLINE FANS

VENTS VKO1 Design Control


Series • The casing and the impeller are made of high- Manual:
quality durable ABS plastic, UV resistant.
• The fan is controlled by a room light switch. It
• The intellectual impeller design makes the fan is not included in the delivery package.
efficiency high and the service life long.
• Speed control is possible through a thyristor
• Protection rating IPX4. speed controller (see Electrical Accessories).
Several fans may connected to the same controller.
Motor Speed controllers can not be connected to the
fans with T, TH, TP, VT, VTH modification.
• Reliable and low-watt electric motor.
Automatic:
• Designed for continuous operation and
requires no maintenance. • By the electronic control unit BU-1-60 (see
Electrical Accessories). The control unit is supplied
• Equipped with overheating protection. separately.

Modifications and Options


• By the timer T (the built-in turn-off delay timer
enables the fan operation within 2 to 30 minutes
VKO1k – fan with a fixing bracket for flat surface after the fan switching off ).
mounting.
VKO1 L – the motor is equipped with Mounting features
Axial inline fans, ball bearings for long service life (appr.
• The fan is mounted into a matching duct size.
for exhaust or supply ventilation with 40 thousand hours) and fan mounting at Fastening with clamps in case of flexible duct
any angle. The bearings are maintenance-free and
the capacity up to 365 m3/h connection.
contain enough grease for the entire operating
period. • The mounting bracket enables fan installation
on both horizontal and vertical flat surfaces
Application VKO1 turbo – high-powered motor. (VKO1k model).

• Continuous or periodic exhaust ventilation • Two fans can be installed in series for higher
of bathroom, showers, kitchens and other utility performance.
VKO1 press – 5-blade low-noise
spaces.
impeller with improved aerodynamics • For 12 V low-voltage motor fan connection
• Exhaust or supply ventilation depending on for higher fan capacity.
to 220 V/50 Hz power mains use the step-down
the fan mounting type in the system. transformer TRF 220/12-25 that is available upon
VKO1 12 – modification with low- separate order.
• Designed for PVC ducting systems or flexible voltage motor. 12 V AC power supply.
ducts.
• Low to medium air flow motion for short VKO1 T – equipped with a regulated
distances at low air resistance.
timer with the operating time from
• Compatible with Ø 100, 125 and 150 mm air 2 to 30 minutes.
ducts.

Mounting examples
VKO1 fan flat
ventilation example

VKO1k fan cottage


ventilation example

Accessories
Backdraft
Diffusers and air disk valves Air ducts Grilles and hoods damper Speed controllers Clamps

82 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Aerodynamic characteristics

Air flow [m3/h] Air flow [m3/h] Air flow [m3/h]

Technical data

Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]

VENTS 100 VKO1 50/60 220-240 14 0.085 2300 107 36 0.41


VENTS 100 VKO1 turbo 50/60 220-240 16 0.1 2300 137 37 0.49
VENTS 100 VKO1 press 50/60 220-240 16 0.1 2300 108 39 0.41
VENTS 100 VKO1 12 50/60 12 14 1.5 2200 94 35 0.40
VENTS 125 VKO1 50/60 220-240 16 0.1 2400 190 38 0.43
VENTS 125 VKO1 turbo 50/60 220-240 24 0.105 2400 245 39 0.51
VENTS 125 VKO1 press 50/60 220-240 24 0.105 2400 194 39 0.43
VENTS 125 VKO1 12 50/60 12 16 1.7 2300 169 37 0.41
VENTS 150 VKO1 50 220-240
VENTS 150 VKO1 29 0.13 2400 305 40 0.80
60 220
(220 V/60 Hz)
VENTS 150 VKO1 turbo 50 220-240
VENTS 150 VKO1 turbo 36 0.16 2400 365 42 0.58
60 220
(220 V/60 Hz)
VENTS 150 VKO1 press 50 220-240
VENTS 150 VKO1 press 36 0.16 2400 317 42 0.80
60 220
(220 V/60 Hz)

VENTS 150 VKO1 12 50 12 29 2 2300 272 39 0.76

Overall dimensions
Dimensions [mm]
Model
ØD Ød B B1 H L L1 L2 L3
VENTS 100 VKO1 100 59 – – – 85 28 – –
VENTS 100 VKO1k 100 59 160 144 110 85 28 45 29
VENTS 125 VKO1 125 59 – – – 90 28 – –
VENTS 125 VKO1k 125 59 185 169 125 90 28 45 29
VENTS 150 VKO1 150 59 – – – 100 28 – –
VENTS 150 VKO1k 150 59 200 184 162 100 28 45 29

Certificates

The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 83


AXIAL WALL- AND
CEILING-MOUNTED FANS

Axial fans for exhaust ventilation with the capacity up to 365 m3/h. Compatible with Ø 100, 125 or
150 mm air ducts. Some models are equipped with automatic or manual louver shutters. Wide range of
designs and options.

Axial fans
VENTS M Series page

Air flow up to 345 m /h


3 86

Axial fans
VENTS M3 Series page

Air flow up to 345 m3/h 88

Axial fans
VENTS M1 Series page

Air flow up to 345 m3/h 90

Axial fans with automatic louvre shutters


VENTS MA Series page

Air flow up to 345 m3/h 92

Axial wall and ceiling fans


VENTS MA reverse Series page

Air flow up to 202 m3/h 94

Axial fans
VENTS X1 Series page

Air flow up to 365 m3/h 96

Axial fans
VENTS Simple Series page

Air flow up to 280 m /h


3 98

Axial fans
VENTS F Series page

Air flow up to 232 m3/h 100

84 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Axial fans
VENTS F1 Series page
Air flow up to 232 m /h3 102

Axial fans
VENTS K Series page
Air flow up to 341 m /h3
104

Axial fans
VENTS K1 Series page
Air flow up to 226 m3/h 106

Axial fans
VENTS PF Series page
Air flow up to 342 m3/h 108

Axial fans
VENTS PF1 Series page
Air flow up to 349 m3/h 110

Axial fans
VENTS S Series page

Air flow up to 341 m3/h 112

Axial fans
VENTS D Series page

Air flow up to 341 m /h3 114

Axial fans
VENTS IFK Series page

Air flow up to 82 m3/h 116

Axial fans
VENTS IFT Series page

Air flow up to 78 m /h
3 117

Axial fans
VENTS IFP Series page

Air flow up to 80 m /h
3 118

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 85


AXIAL WALL- AND CEILING-MOUNTED FANS

VENTS M Design MTP – equipped with a


regulated timer and a motion
Series • Modern design and aesthetic look. sensor with the sensitivity
• The casing and the impeller are made of high- area from 1 to 4 m and the detection angle up to
quality durable ABS plastic, UV resistant. 100°.
• The intellectual impeller design makes the fan
efficiency high and the service life long. Control
• Protection rating IP34. Manual:
• The fan is controlled by a room light switch. It
Motor is not included in the delivery package.
• Reliable and low-watt electric motor. • The fan is controlled by the built-in pull cord
switch V. Not applied in case of ceiling mounting.
• Designed for continuous operation and
requires no maintenance. • Speed control is possible through a thyristor
speed controller (see Electrical Accessories).
• Equipped with overheating protection.
Several fans may connected to the same controller.
Speed controllers can not be connected to the
Modifications and Options fans with T, TH, TP, VT, VTH modification.
M K – fan is equipped with a backdraft Automatic:

Axial fans
damper for back flow preventing. • By the electronic control unit BU-1-60 (see
Electrical Accessories). The control unit is supplied
for exhaust ventilation separately.
M L – the motor is equipped with ball
with the capacity bearings for long service life (appr. 40 • By the timer T (the built-in turn-off delay timer
up to 345 m3/h thousand hours) and fan mounting at enables the fan operation within 2 to 30 minutes
any angle. The bearings are maintenance-free and after the fan switching off ).

Application
contain enough grease for the entire operating • By the humidity sensor and timer TH (if the
period. humidity level in the room exceeds the sensor
• Continuous or periodic exhaust ventilation M turbo – high-powered motor. threshold adjustable value within 60-90 % the fan
of bathroom, showers, kitchens and other utility switches automatically on and operates until the
spaces. humidity level drops to the standard level, after
that the fan continues operating within the time
• Ventilation shaft mounting or duct connec-
M press – 5-blade low-noise impeller period according to the timer setting, then shuts
tion.
with improved aerodynamics for higher down).
• Low to medium air flow motion for short dis- fan capacity. • By the motion sensor and the timer TP (in case
tances at low air resistance.
M 12 – modification with low-voltage of motion detection the fan switches automatically
• Compatible with Ø 100, 125 and 150 mm air motor. 12 V AC power supply. on and operates within the set time period from
ducts. 2 to 30 minutes. The motion sensitivity area is up
to 4 meters and the maximum detection angle is
MT – equipped with a regulated timer 100°).
with the operating time from 2 to 30
minutes.
Mounting features
MTH – equipped with a timer
with the operating time from 2 • The fan is mounted directly into the ventilation
to 30 minutes and a humidity shaft or used for ceiling mounting with the
sensor with the threshold value from 60 to 90 %. connection to the duct.
MV – equipped with a pull cord switch. • Flexible duct application is recommended in
case of remote location of the ventilation shaft.
The air duct is connected to the fan exhaust flange
through a clamp.
MVT – equipped with a pull
cord switch and a regulated • Fixed to wall by self-tapping screws.
timer with the operating time • For 12 V low-voltage motor fan connection
adjustable from 2 to 30 minutes. to 220 V/50 Hz power mains use the step-down
MVTH – equipped transformer TRF 220/12-25 that is available upon
with a pull cord separate order.
switch, regulated
timer with the operating time adjustable from
2 to 30 minutes and a humidity sensor with the
operating threshold range from 60 to 90 %.

Accessories
Backdraft
Air ducts Grilles and hoods damper Speed controllers Clamps

86 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Aerodynamic characteristics
Pressure, ΔP (Pa)

Pressure, ΔP (Pa)

Pressure, ΔP (Pa)
VENTS 100 M VENTS 125 M VENTS 150 M
VENTS 100 M turbo VENTS 125 M turbo VENTS 150 M turbo
VENTS 100 M press VENTS 125 M press VENTS 150 M press
VENTS 100 M VENTS 125 M VENTS 150 M
(127-220 V/60 Hz) (127-220 V/60 Hz) (127-220 V/60 Hz)
VENTS 100 M 12 VENTS 125 M 12 VENTS 150 M 12

Air flow [m3/h] Air flow [m3/h] Air flow [m3/h]

Technical data
Frequency Power Current Maximum air Sound Pressure Weight
Model Voltage [V] R.p.m.
[Hz] Consumption [W] [A] flow [m3/h] Level at 3 m [dBA] [kg]

VENTS 100 M 50/60 220-240 14 0.085 2300 98 34 0.55


VENTS 100 M turbo 50/60 220-240 16 0.1 2300 128 37 0.57
VENTS 100 M press 50/60 220-240 16 0.1 2300 99 37 0.65
VENTS 100 M 127 10 0.115
(127-220 V/60 Hz) 60 2500 92 34 0.55
220 9 0.054
VENTS 100 M 12 50/60 12 14 1.5 2200 86 33 0.50
VENTS 125 M 50/60 220-240 16 0.1 2400 185 35 0.70
VENTS 125 M turbo 50/60 220-240 22 0.105 2400 232 37 0.72
VENTS 125 M press 50/60 220-240 22 0.105 2400 188 39 0.81
VENTS 125 M 127 16 0.119
(127-220 V/60 Hz) 60 2400 190 36 0.70
220 15 0.102
VENTS 125 M 12 50/60 12 16 1.7 2300 165 34 0.70
VENTS 150 M 50 220-240
VENTS 150 M 24 0.13 2400 295 39 0.89
60 220
(220 V/60 Hz)
VENTS 150 M turbo 50 220-240
VENTS 150 M turbo 29 0.13 2400 345 41 0.93
60 220
(220 V/60 Hz)
VENTS 150 M press 50 220-240
VENTS 150 M press 29 0.13 2400 307 41 0.99
60 220
(220 V/60 Hz)
VENTS 150 M 127 25 0.175
(127-220 V/60 Hz) 60 2350 270 39 0.89
220 25 0.338
VENTS 150 M 12 50 12 29 2 2300 263 38 0.89

Mounting example Overall dimensions


Dimensions [mm]
Model
ØD B H L L1
VENTS 100 M 100 159 135 88.5 23
VENTS 125 M 125 180 150 94 25
VENTS 150 M 150 206 182 106 25.5

M fan kitchen
ventilation example

Certificates

The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 87


AXIAL WALL- AND CEILING-MOUNTED FANS

VENTS M3 Design Control


Series • Modern design and aesthetic look. Manual:
• The casing and the impeller are made of high- • The fan is controlled by a room light switch. It
quality durable ABS plastic, UV resistant. is not included in the delivery package.
• The intellectual impeller design makes the fan • The fan is controlled by the built-in pull cord
efficiency high and the service life long. switch V. Not applied in case of ceiling mounting.
• Protection rating IP34. • Speed control is possible through a thyristor
speed controller (see Electrical Accessories).
Motor Several fans may connected to the same controller.
Speed controllers can not be connected to the
• Reliable and low-watt electric motor. fans with T, TH, TP, VT, VTH modification.
• Designed for continuous operation and Automatic:
requires no maintenance.
• By the electronic control unit BU-1-60 (see
• Equipped with overheating protection. Electrical Accessories). The control unit is supplied
separately.
Modifications and Options • By the timer T (the built-in turn-off delay timer
enables the fan operation within 2 to 30 minutes
M3 K – fan is equipped with a backdraft after the fan switching off ).
damper for back flow preventing.
M3 L – the motor is equipped
• By the humidity sensor and timer TH (if the
humidity level in the room exceeds the sensor
with ball bearings for long threshold adjustable value within 60-90 % the fan
service life (appr. 40 thousand switches automatically on and operates until the
hours) and fan mounting at any angle. The humidity level drops to the standard level, after
bearings are maintenance-free and contain that the fan continues operating within the time
Axial fans enough grease for the entire operating period. period according to the timer setting, then shuts
for exhaust ventilation M3 turbo – high-powered motor. down).
with the capacity up to 345 m3/h • By the motion sensor and the timer TP (in case
of motion detection the fan switches automatically
M3 press – 5-blade low-noise impeller on and operates within the set time period from
Application with improved aerodynamics for higher 2 to 30 minutes. The motion sensitivity area is up
fan capacity. to 4 meters and the maximum detection angle is
• Continuous or periodic exhaust ventilation 100°).
of bathroom, showers, kitchens and other utility M3 12 – modification with low-voltage
spaces. motor. 12 V AC power supply.
Mounting features
• Ventilation shaft mounting or duct
connection. M3T – equipped with a regulated timer • The fan is mounted directly into the ventilation
shaft or wall mounted and connected to the air
• For rectangular ventilation shafts. with the operating time from 2 to 30
ducts.
minutes.
• Low to medium air flow motion for short
distances at low air resistance. M3TH – equipped with a • The enlarged front grille modification makes
timer with the operating time the fan suitable for mounting into rectangular
• Compatible with Ø 100, 125 and 150 mm air from 2 to 30 minutes and a ventilation shafts.
ducts.
humidity sensor with the threshold value from 60 • Flexible duct application is recommended in
to 90 %. case of remote location of the ventilation shaft.
M3V – equipped with a pull cord The air duct is connected to the fan exhaust flange
switch. through a clamp.
• Fixed to wall by self-tapping screws.
M3VT – equipped with a pull • For 12 V low-voltage motor fan connection
cord switch and a regulated to 220 V/50 Hz power mains use the step-down
timer with the operating time transformer TRF 220/12-25 that is available upon
adjustable from 2 to 30 minutes. separate order.
M3VTH – equipped
with a pull cord
switch, regulated
timer with the operating time adjustable from
2 to 30 minutes and a humidity sensor with the
operating threshold range from 60 to 90 %.
M3TP – equipped with a
regulated timer and a motion
sensor with the sensitivity
area from 1 to 4 m and the detection angle up to
100°.

Accessories
Backdraft
Air ducts Grilles and hoods damper Speed controllers Clamps

88 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Aerodynamic characteristics

Air flow [m3/h] Air flow [m3/h] Air flow [m3/h]

Technical data

Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]
VENTS 100 M3 50/60 220-240 14 0.085 2300 98 34 0.61
VENTS 100 M3 turbo 50/60 220-240 16 0.1 2300 128 37 0.69
VENTS 100 M3 press 50/60 220-240 16 0.1 2300 99 37 0.69
VENTS 100 M3 12 50/60 12 14 1.5 2200 86 33 0.60
VENTS 125 M3 50/60 220-240 16 0.1 2400 185 35 0.80
VENTS 125 M3 turbo 50/60 220-240 22 0.105 2400 232 40 0.86
VENTS 125 M3 press 50/60 220-240 22 0.105 2400 188 39 0.87
VENTS 125 M3 12 50/60 12 16 1.7 2300 165 34 0.78
VENTS 150 M3 50 220-240
VENTS 150 M3 24 0.13 2400 295 39 0.95
60 220
(220 V/60 Hz)
VENTS 150 M3 turbo 50 220-240
VENTS 150 M3 turbo 29 0.13 2400 345 43 1.01
60 220
(220 V/60 Hz)
VENTS 150 M3 press 50 220-240
VENTS 150 M3 press 29 0.13 2400 307 41 1.03
60 220
(220 V/60 Hz)

VENTS 150 M3 12 50 12 29 2 2300 263 38 0.91

Mounting example Overall dimensions

Dimensions [mm]
Model
ØD B B1 H H1 L L1
VENTS 100 M3 100 185 155 256 226 86 30
VENTS 125 M3 125 185 155 256 226 89 30
VENTS 150 M3 150 185 155 256 226 114 30

Certificates

The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 89


AXIAL WALL- AND CEILING-MOUNTED FANS

VENTS M1 Design M1TP – equipped with a


regulated timer and a motion
Series • Modern design and aesthetic look. sensor with the sensitivity
• The casing and the impeller are made of high- area from 1 to 4 m and the detection angle up to
quality durable ABS plastic, UV resistant. 100°.
• The intellectual impeller design makes the fan
efficiency high and the service life long. Control
• Insect screen. Manual:
• Protection rating IP34. • The fan is controlled by a room light switch. It
is not included in the delivery package.
Motor • The fan is controlled by the built-in pull cord
switch V. Not applied in case of ceiling mounting.
• Reliable and low-watt electric motor.
• Designed for continuous operation and • Speed control is possible through a thyristor
speed controller (see Electrical Accessories).
requires no maintenance.
Several fans may connected to the same controller.
• Equipped with overheating protection. Speed controllers can not be connected to the
fans with T, TH, TP, VT, VTH modification.
Modifications and Options Automatic:

Axial fans
M1 K – fan is equipped with a backdraft • By the electronic control unit BU-1-60 (see
damper for back flow preventing. Electrical Accessories). The control unit is supplied
for exhaust ventilation separately.
with the capacity
M1 L – The motor is equipped with ball • By the timer T (the built-in turn-off delay timer
up to 345 m3/h enables the fan operation within 2 to 30 minutes
bearings for long service life (appr. 40
after the fan switching off ).
thousand hours) and fan mounting at
Application
any angle. The bearings are maintenance-free and • By the humidity sensor and timer TH (if the
contain enough grease for the entire operating humidity level in the room exceeds the sensor
• Continuous or periodic exhaust ventilation period. threshold adjustable value within 60-90 % the fan
of bathroom, showers, kitchens and other utility switches automatically on and operates until the
M1 turbo – high-powered motor.
spaces. humidity level drops to the standard level, after
that the fan continues operating within the time
• Ventilation shaft mounting or duct connec-
period according to the timer setting, then shuts
tion.
M1 press – 5-blade low-noise impeller down).
• Low to medium air flow motion for short dis-
with improved aerodynamics for higher • By the motion sensor and the timer TP (in case
tances at low air resistance.
fan capacity. of motion detection the fan switches automatically
• Compatible with Ø 100, 125 and 150 mm air M1 12 – modification with low-voltage on and operates within the set time period from
ducts. 2 to 30 minutes. The motion sensitivity area is up
motor. 12 V AC power supply.
to 4 meters and the maximum detection angle is
100°).
M1T – equipped with a regulated timer
with the operating time from 2 to 30 Mounting features
minutes.
M1TH – equipped with a • The fan is mounted directly into the ventilation
timer with the operating time shaft.
from 2 to 30 minutes and a • Flexible duct application is recommended in
humidity sensor with the threshold value from 60 case of remote location of the ventilation shaft.
to 90 %. The air duct is connected to the fan exhaust flange
M1V – equipped with a pull cord through a clamp.
switch. • Fixed to wall by self-tapping screws.
• For 12 V low-voltage motor fan connection
M1VT – equipped with a pull to 220 V/50 Hz power mains use the step-down
cord switch and a regulated transformer TRF 220/12-25 that is available upon
timer with the operating time separate order.
adjustable from 2 to 30 minutes.
M1VTH – equipped
with a pull cord
switch, regulated
timer with the operating time adjustable from
2 to 30 minutes and a humidity sensor with the
operating threshold range from 60 to 90 %.

Accessories
Backdraft
Air ducts Grilles and hoods damper Speed controllers Clamps

90 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Aerodynamic characteristics

Air flow [m3/h] Air flow [m3/h] Air flow [m3/h]

Technical data

Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]
VENTS 100 M1 50/60 220-240 14 0.085 2300 98 34 0.51
VENTS 100 M1 turbo 50/60 220-240 16 0.1 2300 128 37 0.65
VENTS 100 M1 press 50/60 220-240 16 0.1 2300 99 37 0.65
VENTS 100 M1 12 50/60 12 14 1.5 2200 86 33 0.51
VENTS 125 M1 50/60 220-240 16 0.1 2400 185 35 0.68
VENTS 125 M1 turbo 50/60 220-240 22 0.105 2400 232 40 0.81
VENTS 125 M1 press 50/60 220-240 22 0.105 2400 188 39 0.81
VENTS 125 M1 12 50/60 12 16 1.7 2300 165 34 0.68
VENTS 150 M1 50 220-240
VENTS 150 M1 24 0.13 2400 295 39 0.80
60 220
(220 V/60 Hz)
VENTS 150 M1 turbo 50 220-240
VENTS 150 M1 turbo 29 0.13 2400 345 43 0.99
60 220
(220 V/60 Hz)
VENTS 150 M1 press 50 220-240
VENTS 150 M1 press 29 0.13 2400 307 41 0.99
60 220
(220 V/60 Hz)

VENTS 150 M1 12 50 12 29 2 2300 262 38 0.76

Mounting example Overall dimensions

Dimensions [mm]
Model
ØD B B1 B2 H L L1
VENTS 100 M1 100 165 150 150 150 92 32
VENTS 125 M1 125 190 174 128 173 98 33
VENTS 150 M1 150 212 196 150 195 114 33

Certificates

The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 91


AXIAL WALL- AND CEILING-MOUNTED FANS

VENTS MA Design Control


Series • Modern design and aesthetic look. Manual:
• The casing and the impeller are made of high- • The fan is controlled by a room light switch. It
quality durable ABS plastic, UV resistant. is not included in the delivery package.
• The intellectual impeller design makes the fan • The fan is controlled by the built-in pull cord
efficiency high and the service life long. switch V. Not applied in case of ceiling mounting.
• Fan is equipped with a thermal actuator Automatic:
that provides smooth opening and shutting
of automatic louver shutters for air back flow
• By the electronic control unit BU-1-60 (see
Electrical Accessories). The control unit is supplied
preventing. separately.
• Protection rating IP24.
• By the timer T (the built-in turn-off delay timer
enables the fan operation within 2 to 30 minutes
Motor after the fan switching off ).

• Reliable and low-watt electric motor. • By the humidity sensor and timer TH (if the
humidity level in the room exceeds the sensor
• Designed for continuous operation and threshold adjustable value within 60-90 % the fan
requires no maintenance. switches automatically on and operates until the
• Equipped with overheating protection. humidity level drops to the standard level, after
that the fan continues operating within the time
Modifications and Options period according to the timer setting, then shuts
Axial fans with automatic louver down).
shutters for exhaust ventilation MA L – the motor is equipped with ball
with the capacity up to 345 m3/h bearings for long service life (appr. 40
• By the motion sensor and the timer TP (in case
of motion detection the fan switches automatically
thousand hours) and fan mounting at on and operates within the set time period from
any angle. The bearings are maintenance-free and 2 to 30 minutes. The motion sensitivity area is up
Application contain enough grease for the entire operating to 4 meters and the maximum detection angle is
period. 100°).
• Continuous or periodic exhaust ventilation MA turbo – high-powered motor.
of bathroom, showers, kitchens and other utility
spaces. Mounting features
• Ventilation shaft mounting or duct connection.
MA press – 5-blade low-noise • The fan is mounted directly into the ventilation
• Low to medium air flow motion for short impeller with improved aerodynamics shaft.
distances at low air resistance. for higher fan capacity. • Flexible duct application is recommended in
• Compatible with Ø 100, 125 and 150 mm air MA 12 – modification with low-voltage case of remote location of the ventilation shaft.
ducts. motor. 12 V AC power supply. The air duct is connected to the fan exhaust flange
through a clamp.

MAT – equipped with a regulated timer


• Fixed to wall by self-tapping screws.

with the operating time from 2 to 30 • Suitable for ceiling mounting.


minutes. • Flange of 92 mm length for easy mounting
MATH – equipped with a tim- into concrete walls and floor decks up to
er with the operating time from 100 mm thick.
2 to 30 minutes and a humidity • For 12 V low-voltage motor fan connection
sensor with the threshold value from 60 to 90 %. to 220 V/50 Hz power mains use the step-down
MAV – equipped with a pull cord transformer TRF 220/12-25 that is available upon
switch. separate order.

MAVT – equipped with a pull


Fan OFF – louver shutters CLOSED cord switch and a regulated
timer with the operating time
adjustable from 2 to 30 minutes.
MAVTH – equipped
with a pull cord
switch, regulated
timer with the operating time adjustable from 2 to
30 minutes and a humidity sensor with the
operating threshold range from 60 to 90 %.
MATP – equipped with a
regulated timer and a motion
sensor with the sensitivity area
Fan ON – louver shutters OPEN from 1 to 4 m and the detection angle up to 100°.

Accessories
Air ducts Grilles and hoods Speed controllers Clamps

92 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Aerodynamic characteristics

Air flow [m3/h] Air flow [m3/h] Air flow [m3/h]

Technical data

Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]
VENTS 100 MA 50/60 220-240 18 0.085 2300 98 34 0.65
VENTS 100 MA turbo 50/60 220-240 20 0.1 2300 128 37 0.65
VENTS 100 MA press 50/60 220-240 20 0.1 2300 99 37 0.65
VENTS 100 MA 12 50/60 12 18 1.5 2200 86 33 0.65
VENTS 125 MA 50/60 220-240 22 0.1 2400 185 35 0.75
VENTS 125 MA turbo 50/60 220-240 29 0.13 2400 232 37 0.81
VENTS 125 MA press 50/60 220-240 29 0.13 2400 188 39 0.81
VENTS 125 MA 12 50/60 12 22 1.7 2300 165 34 0.75
VENTS 150 MA 50 220-240
VENTS 150 MA 26 0.13 2400 295 39 1.02
60 220
(220 V/60 Hz)
VENTS 150 MA turbo 50 220-240
VENTS 150 MA turbo 32 0.13 2400 345 41 0.99
60 220
(220 V/60 Hz)
VENTS 150 MA press 50 220-240
VENTS 150 MA press 32 0.14 2400 307 41 0.99
60 220
(220 V/60 Hz)

VENTS 150 MA 12 50 12 29 2 2300 263 38 0.98

Mounting example Overall dimensions


Dimensions [mm]
Model
ØD B B1 B2 H L L1
VENTS 100 MA 100 165 150 150 150 92 32
VENTS 125 MA 125 190 174 128 173 98 33
VENTS 150 MA 150 212 196 150 195 114 33

Certificates

The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 93


AXIAL WALL- AND CEILING-MOUNTED FANS

VENTS MA reverse Application Motor


Series • Continuous or periodic exhaust and supply • Reliable DC motor (12 V) with low energy
ventilation of bathrooms, showers, kitchens, demand.
garages and other residential spaces.
• Two-speed reverse DC motor provides fan
• Mounting on the external wall together operation both in supply and exhaust mode.
with ventilation kit that includes an air duct and
an external grille provides the most efficient
• Special motor design ensures low noise level.

operation. • Designed for continuous operation and


requires no maintenance.
• Compatible with Ø 150 mm air ducts.
• Equipped with overheating protection.

Design
Control
• Modern design and aesthetic look.
Manual:
• The casing and the impeller are made of high-
• Three bottom control unit (included into
quality durable ABS plastic, UV resistant.
delivery set) with integrated circuit board is used
• The intellectual impeller design makes the fan for:
efficiency high and the service life long.
1. On/off switching;
• Fan is equipped with a thermal actuator
2. Fan speed switching (min – max);
that provides smooth opening and shutting
of automatic louver shutters for air back flow 3. Fan operation mode switching (exhaust –
Axial reverse fans for exhaust and preventing. supply mode).
supply ventilation with the capacity • Supplied with a three bottom control unit and
up to 202 m3/h 220 V – 12 V transformer. Mounting features
• Transformer provides reliable fan operation
• Fan is designed for indoor mounting on the
with safe power supply 12 V. external wall and is connected to the air duct.
• Protection rating IP24.
• Fastening with screws. Flexible air duct is
connected to exhaust flange with a clamp.

Exhaust mode 2 speed On

Fan off – louver shutters CLOSED Control unit Supply mode 1 speed Off

Fan on – louver shutters OPEN Fan operation in EXHAUST mode Fan operation in SUPPLY mode

Accessories
Air ducts Grilles and hoods Clamps

94 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Aerodynamic characteristics

Air flow [m3/h]

Technical data

Power Sound Pressure


Frequency Voltage Current Maximum air Weight
Model Mode Speed Consumption R.p.m. Level at 3 m
[Hz] [V] [A] flow [m3/h] [kg]
[W] [dBA]

max 8.7 0.045 1950 202 33


exhaust
min 5.2 0.025 1215 123 28
VENTS 150 MA reverse 50/60 220-240 1.02
max 7.6 0.045 2030 187 32
supply
min 5.1 0.025 1210 110 26

Mounting set

Fan Telescopic duct Ventilation grille


Vents 150 MA reverse (Ø 150, length 350-500 mm) MV 250/150 Vs

Mounting example Overall dimensions

Dimensions [mm]
Model
ØD B B1 B2 H L L1
VENTS 150 MA reverse 150 212 196 150 195 114 33

Certificates

The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 95


AXIAL WALL- AND CEILING-MOUNTED FANS

VENTS X1 Design Control


Series • Modern design and aesthetic look. Manual:
• The casing and the impeller are made of high- • The fan is controlled by a room light switch. It
quality durable ABS plastic, UV resistant. is not included in the delivery package.
• The intellectual impeller design makes the fan • The fan is controlled by the built-in pull cord
efficiency high and the service life long. switch V. Not applied in case of ceiling mounting.
• Protection rating IP24. • Speed control is possible through a thyristor
speed controller (see Electrical Accessories).
Motor Several fans may connected to the same controller.
Speed controllers can not be connected to the
• Reliable and low-watt electric motor. fans with T, TH, TP, VT, VTH modification.
• Designed for continuous operation and Automatic:
requires no maintenance.
• By the electronic control unit BU-1-60 (see
• Equipped with overheating protection. Electrical Accessories). The control unit is supplied
separately.
Modifications and Options • By the timer T (the built-in turn-off delay timer
enables the fan operation within 2 to 30 minutes
X1 K – fan is equipped with a backdraft after the fan switching off ).
Axial fans damper for back flow preventing.
for exhaust ventilation with the • By the humidity sensor and timer TH (if the
humidity level in the room exceeds the sensor
capacity up to 345 m3/h X1 L – the motor is equipped with ball threshold adjustable value within 60-90 % the fan
bearings for long service life (appr. 40 switches automatically on and operates until the
thousand hours) and fan mounting at humidity level drops to the standard level, after
Application any angle. The bearings are maintenance-free and that the fan continues operating within the time
contain enough grease for the entire operating period according to the timer setting, then shuts
• Continuous or periodic exhaust ventilation period. down).
of bathroom, showers, kitchens and other utility
spaces. X1 turbo – high-powered motor.
Mounting features
• Ventilation shaft mounting or duct connec-
tion. • The fan is mounted directly into the ventilation
X1 12 – modification with low-voltage shaft.
• Low to medium air flow motion for short dis-
tances at low air resistance. motor. 12 V AC power supply. • Flexible duct application is recommended in
case of remote location of the ventilation shaft.
• Compatible with Ø 100, 120, 125 and 150 mm The air duct is connected to the fan exhaust flange
air ducts. X1T – equipped with a regulated timer through a clamp.
with the operating time from 2 to 30
minutes. • Fixed to wall by self-tapping screws.
X1TH – equipped with a timer • Suitable for ceiling mounting.
with the operating time from 2 • For 12 V low-voltage motor fan connection
to 30 minutes and a humidity to 220 V/50 Hz power mains use the step-down
sensor with the threshold value from 60 to 90 %. transformer TRF 220/12-25 that is available upon
X1V – equipped with a pull cord switch. separate order.

X1VT – equipped with a pull


cord switch and a regulated
timer with the operating time
adjustable from 2 to 30 minutes.
X1VTH – equipped
with a pull cord
switch, regulated
timer with the operating time adjustable from
7 mm 2 to 30 minutes and a humidity sensor with the
operating threshold range from 60 to 90 %.

Accessories
Backdraft
Air ducts Grilles and hoods damper Speed controllers Clamps

96 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Aerodynamic characteristics
Pressure, ΔР [Pa]

Pressure, ΔР [Pa]

Pressure, ΔР [Pa]

Pressure, ΔР [Pa]
VENTS 100 Х1 VENTS 120 Х1 VENTS 125 Х1 VENTS 150 Х1

VENTS 100 Х1 turbo VENTS 120 Х1 turbo VENTS 125 Х1 turbo VENTS 150 Х1 turbo
VENTS 100 Х1 12 VENTS 120 Х1 12 VENTS 125 Х1 12 VENTS 150 Х1 12

Air flow [m3/h] Air flow [m3/h] Air flow [m3/h] Air flow [m3/h]

Technical data
Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]
VENTS 100 X1 50 220-240
14 0.085 2300 99 33 0.60
VENTS 100 X1 (220 V/60 Hz) 60 220
VENTS 100 X1 turbo 50 220-240
16 0.1 2300 129 37 0.68
VENTS 100 X1 turbo (220 V/60 Hz) 60 220
VENTS 100 X1 12 50 12 14 1.5 2200 86 33 0.59
VENTS 120 X1 50 220-240
17 0.1 2400 179 35 0.73
VENTS 120 X1 (220 V/60 Hz) 60 220
VENTS 120 X1 turbo 50 220-240
24 0.105 2400 225 37 0.80
VENTS 120 X1 turbo (220 V/60 Hz) 60 220
VENTS 120 X1 12 50 12 16 1.7 2300 160 34 0.71
VENTS 125 X1 50 220-240
16 0.1 2400 185 34 0.73
VENTS 125 X1 (220 V/60 Hz) 60 220
VENTS 125 X1 turbo 50 220-240
24 0.105 2400 232 37 0.80
VENTS 125 X1 turbo (220 V/60 Hz) 60 220
VENTS 125 X1 12 50 12 16 1.7 2300 160 34 0.71
VENTS 150 X1 50 220-240
24 0.13 2400 295 37 0.92
VENTS 150 X1 (220 V/60 Hz) 60 220
VENTS 150 X1 turbo 50 220-240
29 0.13 2400 345 41 1.06
VENTS 150 X1 turbo (220 V/60 Hz) 60 220
VENTS 150 X1 12 50 12 29 2 2300 263 36 0.88

Mounting example Overall dimensions

Dimensions [mm]
Model
ØD B H L L1
VENTS 100 X1 100 152 120 108 12
VENTS 120 X1 120 177 140 95 13
VENTS 125 X1 125 177 140 114 13
VENTS 150 X1 150 205 165 132 13

Certificates

The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 97


AXIAL WALL- AND CEILING-MOUNTED FANS

VENTS Simple Motor Control


Manual:
Series • Reliable and low-watt electric motor.
• Designed for continuous operation and requires • The fan is controlled by a room light switch. It is
no maintenance. not included in the delivery set.

• Equipped with overheating protection. • The fan is controlled by the built-in V pull cord
switch. Not applied in case of ceiling mounting.
Modifications and Options • Speed control is possible through a thyristor
speed controller (see Electrical Accessories). Several
Simple K – fan is equipped with a backdraft fans may be connected to the same controller. Speed
damper for back flow preventing. controllers can not be connected to the fans with the
T, TH, TP, VT, VTH modifications.
Simple L – the motor is equipped with Automatic:
ball bearings for long service life (appr. • By the BU-1-60 electronic control unit (see
40 thousand hours) and fan mounting at Electrical Accessories). The control unit is supplied
any angle. The bearings are maintenance-free and separately.
contain enough grease for the entire operating
period.
• By the T timer (the built-in turn-off delay timer
enables the fan operation within 2 to 30 minutes
Simple turbo – high-powered motor. after the fan switching off).

Axial fans • By the humidity sensor and the TH timer (if


the humidity level in the room exceeds the sensor
for exhaust ventilation threshold adjustable value within 60-90  %, the fan
Simple T – equipped with a regulated
with air capacity timer with the operating time from 2 to 30 switches automatically on and operates until the
up to 280 m3/h minutes. humidity level drops to the standard level, after that
Simple TH – equipped with a the fan continues operating within the time period
timer with the operating time according to the timer setting, then shuts down).
Application from 2 to 30 minutes and a
humidity sensor with the threshold value from 60 to Mounting features
• Continuous or periodic exhaust ventilation of
bathroom, showers, kitchens and other utility spaces. 90 %. • The fan is mounted directly into the ventilation
Simple V – equipped with a pull cord shaft.
• Ventilation shaft mounting or duct connection.
• Low to medium air flow motion for short distances
switch. • In case of remote location of the ventilation
shaft flexible air ducts may be used. The air duct
at low air resistance. is connected to the fan exhaust flange through a
• Compatible with Ø 100, 120, 125 and 150 mm air Simple VT – equipped with a clamp.
ducts. pull cord switch and a regulated • Fixed to the wall by means of screws.
timer with the operating time
adjustable from 2 to 30 minutes.
• Can be ceiling mounted in case the fan is ordered
with ball bearings (Simple L modification).
Design Simple VTH –
equip­­ped with a pull
• Modern design and aesthetic look.
cord switch, regulat-
• The casing and the impeller are made of high- ed timer with the operating time adjustable from 2
quality durable ABS plastic, UV resistant. to 30 minutes and a humidity sensor with the oper-
• The intellectual impeller design makes the fan ating threshold range from 60 to 90 %.
efficiency high and the service life long.
• Insect screen.
• Protection rating IP34.

Accessories
Backdraft
Air ducts Grilles and hoods damper Speed controllers Clamps

98 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Aerodynamic characteristics
Air flow [l/s] Air flow [l/s] Air flow [l/s] Air flow [l/s]
0 5 10 15 20 25 30 35 0 10 20 30 40 50 60 0 10 20 30 40 50 60 0 20 40 60 80
45 70 70 90
Pressure ∆P [Pa]

Pressure ∆P [Pa]

Pressure ∆P [Pa]

Pressure ∆P [Pa]
100 Simple turbo 120 Simple turbo 125 Simple turbo 150 Simple
40 80
100 Simple 60 120 Simple 60 125 Simple
35 70
50 50
30 60

25 40 40 50

20 30 30 40

15 30
20 20
10 20

10 10
5 10

0 0 0 0
0 20 40 60 80 100 120 140 0 40 80 120 160 200 240 0 40 80 120 160 200 240 0 50 100 150 200 250 300

Air flow [m3/h] Air flow [m3/h] Air flow [m3/h] Air flow [m3/h]

Technical data

Power Maximum Specific Sound Pressure


Model Frequency Voltage Current Weight IP
Consumption Air Flow Power Level at 3 m

[Hz] [V] [W] [A] [m3/h] [l/s] [W/l/s] [dBA] [kg]


50 220-240
VENTS 100 Simple 14 0.09 95 26 0.53 34 0.58 IP34
60 220
50 220-240
VENTS 100 Simple turbo 16 0.01 124 34 0.46 37 0.66 IP34
60 220
50 220-240
VENTS 120 Simple 16 0.09 174 48 0.33 35 0.74 IP34
60 220
50 220-240
VENTS 120 Simple turbo 24 0.1 219 61 0.39 37 0.81 IP34
60 220
50 220-240
VENTS 125 Simple 16 0.1 180 50 0.32 35 0.74 IP34
60 220
50 220-240
VENTS 125 Simple turbo 24 0.105 226 63 0.38 37 0.81 IP34
60 220
VENTS 150 Simple 50 220-240
25 0.17 280 78 0.32 34 0.92 IP34
VENTS 150 Simple turbo 60 220

Mounting example Overall dimensions


Dimensions [mm]
Model
ØD B H L L1
VENTS 100 Simple 100 150 125 97 15
VENTS 120 Simple 120 175 140 94 15
VENTS 125 Simple 125 175 140 101 15
VENTS 150 Simple 150 205 165 117 15

Certificates

The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 99


AXIAL WALL- AND CEILING-MOUNTED FANS

VENTS F Design Control


Series • Modern design and aesthetic look. Manual:

• The casing and the impeller are made of high- • The fan is controlled by a room light switch. It
quality durable ABS plastic, UV resistant. is not included in the delivery package.

• The intellectual impeller design makes the fan • Speed control is possible through a thyristor
efficiency high and the service life long. speed controller (see Electrical Accessories).
Several fans may connected to the same controller.
• The special front grille design enables natural Speed controllers can not be connected to the
ventilation of the premises without powering up fans with T, TH, TP, VT, VTH modification.
the fan if required.
Automatic:
• Insect screen.
• Protection rating IP34.
• By the electronic control unit BU-1-60 (see
Electrical Accessories). The control unit is supplied
• Ventilation grille for natural air exhaust for separately.
application in premises with gas stoves.
Mounting features
Motor • The fan is mounted directly into the ventilation
shaft.
• Reliable and low-watt electric motor.
• Designed for continuous operation and • Flexible duct application is recommended in
case of remote location of the ventilation shaft.
requires no maintenance.
The air duct is connected to the fan exhaust flange
• Equipped with overheating protection. through a clamp.
• Fixed to wall by self-tapping screws.
Modifications and Options
• For 12 V low-voltage motor fan connection
F L – the motor is equipped with ball to 220 V/50 Hz power mains use the step-down
Axial fans bearings for long service life (appr. 40 transformer TRF 220/12-25 that is available upon
for exhaust ventilation thousand hours) and fan mounting at separate order.
with the capacity up to 232 m3/h any angle. The bearings are maintenance-free and
contain enough grease for the entire operating
period.
Application F turbo – high-powered motor.
• Continuous or periodic exhaust ventilation
of bathroom, showers, kitchens and other utility
spaces. F 12 – modification with low-voltage
• Ventilation shaft mounting or duct connec- motor. 12 V AC power supply.
tion.
• For rectangular ventilation shafts.
• Low to medium air flow motion for short dis-
tances at low air resistance.
• Compatible with Ø 100 and 125 mm air ducts.

Accessories
Backdraft
Air ducts Grilles and hoods damper Speed controllers Clamps

100 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Aerodynamic characteristics

Air flow [m3/h] Air flow [m3/h]

Technical data

Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]

VENTS 100 F 50/60 220-240 14 0.085 2300 98 34 0.64


VENTS 100 F turbo 50/60 220-240 16 0.1 2300 128 37 0.72
VENTS 100 F 12 50/60 12 14 1.5 2200 86 33 0.63
VENTS 125 F 50/60 220-240 16 0.1 2400 185 35 0.70
VENTS 125 F turbo 50/60 220-240 24 0.1 2400 232 37 0.77
VENTS 125 F 12 50/60 12 16 1.7 2300 165 34 0.68

Mounting example Overall dimensions

Dimensions [mm]
Model
ØD B B1 B2 H H1 L L1
VENTS 100 F 100 182 152 160 252 226 104 13
VENTS 125 F 125 182 152 160 252 226 110 15

Certificates

The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 101


AXIAL WALL- AND CEILING-MOUNTED FANS

VENTS F1 Design Control


Series • Modern design and aesthetic look. Manual:

• The casing and the impeller are made of high- • The fan is controlled by a room light switch. It
quality durable ABS plastic, UV resistant. is not included in the delivery package.

• The intellectual impeller design makes the fan • Speed control is possible through a thyristor
efficiency high and the service life long. speed controller (see Electrical Accessories).
Several fans may connected to the same controller.
• The special front grille design enables natural Speed controllers can not be connected to the
ventilation of the premises without powering up fans with T, TH, TP, VT, VTH modification.
the fan if required.
Automatic:
• The enlarged front grille is specifically
designed to fit non-standard ventilation shafts. • By the electronic control unit BU-1-60 (see
Electrical Accessories). The control unit is supplied
• Insect screen. separately.
• Protection rating IP34.
• By the timer T (the built-in turn-off delay timer
• Ventilation grille for natural air exhaust for enables the fan operation within 2 to 30 minutes
application in premises with gas stoves. after the fan switching off ).

Motor Mounting features

• Reliable and low-watt electric motor. • The fan is mounted directly into the ventilation
shaft.
• Designed for continuous operation and
• Flexible duct application is recommended in
requires no maintenance.
case of remote location of the ventilation shaft.
• Equipped with overheating protection. The air duct is connected to the fan exhaust flange
Axial fans through a clamp.
for exhaust ventilation Modifications and Options • Fixed to wall by self-tapping screws.
with the capacity up to 232 m3/h F1 L – the motor is equipped with ball • For 12 V low-voltage motor fan connection
bearings for long service life (appr. 40 to 220 V/50 Hz power mains use the step-down
thousand hours) and fan mounting at transformer TRF 220/12-25 that is available upon
Application any angle. The bearings are maintenance-free and separate order.
contain enough grease for the entire operating
• Continuous or periodic exhaust ventilation period.
of bathroom, showers, kitchens and other utility
spaces. F1 turbo – high-powered motor.
• Ventilation shaft mounting or duct connec-
tion.
• Designed for non-standard ventilation shafts F1 12 – modification with low-voltage
with a large cross section. motor. 12 V AC power supply.
• Low to medium air flow motion for short dis-
tances at low air resistance. F1T – equipped with a regulated timer
• Compatible with Ø 100 and 125 mm air ducts. with the operating time from 2 to 30
minutes.

Accessories
Backdraft
Air ducts Grilles and hoods damper Speed controllers Clamps

102 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Aerodynamic characteristics

Air flow [m3/h] Air flow [m3/h]

Technical data

Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]

VENTS 100 F1 50/60 220-240 14 0.085 2300 100 33 0.58


VENTS 100 F1 turbo 50/60 220-240 16 0.1 2300 122 36 0.68
VENTS 100 F1 12 50/60 12 14 1.5 2200 88 32 0.58
VENTS 125 F1 50/60 220-240 16 0.1 2400 190 35 0.80
VENTS 125 F1 turbo 50/60 220-240 24 0.105 2400 232 37 0.85
VENTS 125 F1 12 50/60 12 16 1.7 2300 169 34 0.80

Mounting example Overall dimensions

Dimensions [mm]
Model
ØD B B1 B2 H H1 L L1
VENTS 100 F1 100 182 152 160 252 226 128 13
VENTS 125 F1 125 182 152 160 252 226 134 15

Certificates

The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 103


AXIAL WALL- AND CEILING-MOUNTED FANS

VENTS K Design Control


Series • Classic design and aesthetic look. Manual:

• The casing and the impeller are made of high- • The fan is controlled by a room light switch. It
quality durable ABS plastic, UV resistant. is not included in the delivery package.

• The intellectual impeller design makes the fan • Speed control is possible through a thyristor
efficiency high and the service life long. speed controller (see Electrical Accessories).
Several fans may connected to the same controller.
• Insect screen. Speed controllers can not be connected to the
• Protection rating IP34. fans with T, TH, TP, VT, VTH modification.
Automatic:
Motor
• By the electronic control unit BU-1-60 (see
• Reliable and low-watt electric motor. Electrical Accessories). The control unit is supplied
separately.
• Designed for continuous operation and
requires no maintenance.
Mounting features
• Equipped with overheating protection.
• The fan is mounted directly into the ventilation
shaft.
Modifications and Options
• Flexible duct application is recommended in
K L – the motor is equipped with ball case of remote location of the ventilation shaft.
bearings for long service life (appr. 40 The air duct is connected to the fan exhaust flange
Axial fans thousand hours) and fan mounting at through a clamp.
for exhaust ventilation any angle. The bearings are maintenance-free and • Fixed to wall by self-tapping screws.
with the capacity up to 341 m3/h contain enough grease for the entire operating
period. • Suitable for ceiling mounting.

K turbo – high-powered motor. • For 12 V low-voltage motor fan connection


Application to 220 V/50 Hz power mains use the step-down
transformer TRF 220/12-25 that is available upon
• Continuous or periodic exhaust ventilation separate order.
of bathroom, showers, kitchens and other utility K 12 – modification with low-voltage
spaces. motor. 12 V AC power supply.
• Ventilation shaft mounting or duct connec-
tion.
• Low to medium air flow motion for short dis-
tances at low air resistance.
• Compatible with Ø 100, 125 and 150 mm air
ducts.

Accessories
Backdraft
Air ducts Grilles and hoods damper Speed controllers Clamps

104 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Aerodynamic characteristics

Air flow [m3/h] Air flow [m3/h] Air flow [m3/h]

Technical data

Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]

VENTS 100 K 50/60 220-240 14 0.085 2300 95 34 0.53


VENTS 100 K turbo 50/60 220-240 16 0.1 2300 124 37 0.61
VENTS 100 K 12 50/60 12 14 1.5 2200 83 33 0.52
VENTS 125 K 50/60 220-240 16 0.1 2400 180 35 0.65
VENTS 125 K turbo 50/60 220-240 24 0.105 2400 226 37 0.72
VENTS 125 K 12 50/60 12 16 1.7 2300 161 34 0.63
VENTS 150 K 50 220-240
VENTS 150 K 24 0.13 2400 292 38 1.07
60 220
(220 V/60 Hz)
VENTS 150 K turbo 50 220-240
VENTS 150 K turbo 29 0.13 2400 341 40 1.21
60 220
(220 V/60 Hz)

VENTS 150 K 12 50 12 29 2 2300 260 37 1.03

Mounting example Overall dimensions

Dimensions [mm]
Model
ØD B H L L1
VENTS 100 K 100 154 110 105 15
VENTS 125 K 125 187 142 112 15
VENTS 150 K 150 250 214 127 15

Certificates

The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 105


AXIAL WALL- AND CEILING-MOUNTED FANS

VENTS K1 Design Control


Series • Classic design and aesthetic look. Manual:

• The casing and the impeller are made of high- • The fan is controlled by a room light switch. It
quality durable ABS plastic, UV resistant. is not included in the delivery package.

• The intellectual impeller design makes the fan • Speed control is possible through a thyristor
efficiency high and the service life long. speed controller (see Electrical Accessories).
Several fans may connected to the same controller.
• Insect screen. Speed controllers can not be connected to the
• Protection rating IP34. fans with T, TH, TP, VT, VTH modification.
Automatic:
Motor
• By the electronic control unit BU-1-60 (see
Electrical Accessories). The control unit is supplied
• Reliable and low-watt electric motor.
separately.
• Designed for continuous operation and
requires no maintenance.
Mounting features
• Equipped with overheating protection.
• The fan is mounted directly into the ventilation
shaft.
Modifications and Options
• Flexible duct application is recommended in
K1 L – The motor is equipped with ball case of remote location of the ventilation shaft.
bearings for long service life (appr. 40 The air duct is connected to the fan exhaust flange
Axial fans thousand hours) and fan mounting at through a clamp.
for exhaust ventilation any angle. The bearings are maintenance-free and • Fixed to wall by self-tapping screws.
with the capacity up to 226 m3/h contain enough grease for the entire operating
period. • Suitable for ceiling mounting.

K1 turbo – high-powered motor. • For 12 V low-voltage motor fan connection


Application to 220 V/50 Hz power mains use the step-down
transformer TRF 220/12-25 that is available upon
• Continuous or periodic exhaust ventilation separate order.
of bathroom, showers, kitchens and other utility K1 12 – modification with low-voltage
spaces. motor. 12 V AC power supply.
• Ventilation shaft mounting or duct connec-
tion.
• Low to medium air flow motion for short dis-
tances at low air resistance.
• Compatible with Ø 100 and 125 mm air ducts.

Accessories
Backdraft
Air ducts Grilles and hoods damper Speed controllers Clamps

106 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Aerodynamic characteristics

Air flow [m3/h] Air flow [m3/h]

Technical data

Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]

VENTS 100 K1 50/60 220-240 14 0.085 2300 95 34 0.52


VENTS 100 K1 turbo 50/60 220-240 16 0.1 2300 124 37 0.60
VENTS 100 K1 12 50/60 12 14 1.5 2200 83 33 0.50
VENTS 125 K1 50/60 220-240 16 0.1 2400 180 35 0.70
VENTS 125 K1 turbo 50/60 220-240 24 0.105 2400 226 37 0.77
VENTS 125 K1 12 50/60 12 16 1.7 2300 161 34 0.66

Mounting example Overall dimensions

Dimensions [mm]
Model
ØD B H L L1
VENTS 100 K1 100 154 110 108.5 18.5
VENTS 125 K1 125 187 142 116 19

Certificates

The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 107


AXIAL WALL- AND CEILING-MOUNTED FANS

VENTS PF Design Control


Series • Modern design and aesthetic look. Manual:

• The casing and the impeller are made of high- • The fan is controlled by a room light switch. It
quality durable ABS plastic, UV resistant. is not included in the delivery set.

• The intellectual impeller design makes the fan • Speed control is possible through a thyristor
efficiency high and the service life long. speed controller (see Electrical Accessories).
Several fans may be connected to the same
• Insect screen. controller. Speed controllers can not be
• Protection rating IP34. connected to the fans with the T, TH, TP, VT, VTH
modifications.
Motor Automatic:

• Reliable and low-watt electric motor. • By the BU-1-60 electronic control unit (see
Electrical Accessories). The control unit is supplied
• Designed for continuous operation and
separately.
requires no maintenance.
• Equipped with overheating protection. Mounting features
• The fan is mounted directly into the ventilation
Modifications and Options shaft.
PF L – the motor is equipped with ball • In case of remote location of the ventilation
bearings for long service life (appr. 40 shaft flexible air ducts may be used. The air duct
Axial fans for exhaust thousand hours) and fan mounting at is connected to the fan exhaust flange through a
ventilation with air capacity any angle. The bearings are maintenance-free and clamp.
up to 342 m3/h contain enough grease for the entire operating • Fixed to wall by self-tapping screws.
period.
• Suitable for ceiling mounting.
PF turbo – high-powered motor.
Application • To connect a fan with a 12 V low voltage motor
to 220 V/50 Hz power mains, it is necessary to
• Continuous or periodic exhaust ventilation purchase a step-down transformer (e.g. the TRF
of bathroom, showers, kitchens and other utility PF press – 5-blade low-noise impeller 220/12-25 transformer).
spaces. with improved aerodynamics for higher
• Ventilation shaft mounting or duct connec- fan capacity.
tion. PF 12 – modification with low-voltage
• Low to medium air flow motion for short dis- motor. 12 V AC power supply.
tances at low air resistance.
• Compatible with Ø 100, 125 and 150 mm air
ducts.

Accessories
Backdraft
Air ducts Grilles and hoods damper Speed controllers Clamps

108 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Aerodynamic characteristics
Pressure, ΔP [Pa]

Pressure, ΔP [Pa]

Pressure, ΔP [Pa]
VENTS 100 PF VENTS 125 PF VENTS 150 PF
VENTS 100 PF turbo VENTS 125 PF turbo VENTS 150 PF turbo
VENTS 100 PF press VENTS 125 PF press VENTS 150 PF press
VENTS 100 PF VENTS 125 PF VENTS 150 PF
(127-220 V/60 Hz) (127-220 V/60 Hz) (127-220 V/60 Hz)
VENTS 100 PF 12 VENTS 125 PF 12 VENTS 150 PF 12

Air flow [m3/h] Air flow [m3/h] Air flow [m3/h]

Technical data
Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]
VENTS 100 PF 50/60 220-240 14 0.085 2300 98 34 0.47
VENTS 100 PF turbo 50/60 220-240 16 0.1 2300 120 40 0.52
VENTS 100 PF press 50/60 220-240 16 0.1 2300 99 38 0.47
VENTS 100 PF 127 10 0.115
(127-220 V/60 Hz) 60 2500 92 34 0.47
220 9 0.054
VENTS 100 PF 12 50/60 12 14 1.5 2200 86 33 0.46
VENTS 125 PF 50/60 220-240 16 0.1 2400 185 35 0.58
VENTS 125 PF turbo 50/60 220-240 24 0.1 2400 230 42 0.60
VENTS 125 PF press 50/60 220-240 24 0.105 2400 188 39 0.58
VENTS 125 PF 127 16 0.119
(127-220 V/60 Hz) 60 2400 190 36 0.58
220 15 0.102
VENTS 125 PF 12 50/60 12 16 1.7 2300 165 34 0.56
VENTS 150 PF 50 220-240
VENTS 150 PF 24 0.13 2400 292 38 0.90
60 220
(220 V/60 Hz)
VENTS 150 PF turbo 50 220-240
VENTS 150 PF turbo 29 0.13 2400 342 42 1.02
60 220
(220 V/60 Hz)
VENTS 150 PF press 50 220-240
VENTS 150 PF press 29 0.13 2400 304 40 0.90
60 220
(220 V/60 Hz)
VENTS 150 PF 127 25 0.175
(127-220 V/60 Hz) 60 2350 267 38 0.90
220 25 0.388

VENTS 150 PF 12 50 12 29 2 2300 260 37 0.74

Mounting example Overall dimensions


Dimensions [mm]
Model
Ø D Ø D1 L L1
VENTS 100 PF 100 141 104 13
VENTS 125 PF 125 166 110 15
VENTS 150 PF 150 188 125 15

Certificates

The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 109


AXIAL WALL- AND CEILING-MOUNTED FANS

VENTS PF1 Design Control


Manual:
Series • Modern design and aesthetic look.
• The casing and the impeller are made of high- • The fan is controlled by a room light switch. It
quality durable ABS plastic, UV resistant. is not included in the delivery package.

• The intellectual impeller design makes the fan • Speed control is possible through a thyristor
efficiency high and the service life long. speed controller (see Electrical Accessories).
Several fans may connected to the same controller.
• Insect screen. Speed controllers can not be connected to the
• Protection rating IP34. fans with T, TH, TP, VT, VTH modification.
Automatic:
Motor
• By the electronic control unit BU-1-60 (see
Electrical Accessories). The control unit is supplied
• Reliable and low-watt electric motor.
separately.
• Designed for continuous operation and
requires no maintenance. • By the timer T (the built-in turn-off delay timer
enables the fan operation within 2 to 30 minutes
• Equipped with overheating protection.
after the fan switching off ).

Modifications and Options Mounting features

Axial fans
PF1 L – The motor is equipped with ball • The fan is mounted directly into the ventilation
bearings for long service life (appr. 40 shaft.
for exhaust ventilation
with the capacity
thousand hours) and fan mounting at • Flexible duct application is recommended in
any angle. The bearings are maintenance-free and case of remote location of the ventilation shaft.
up to 349 m3/h contain enough grease for the entire operating The air duct is connected to the fan exhaust flange
period. through a clamp.

Application
PF1 turbo – high-powered motor. • Fixed to wall by self-tapping screws.
• Suitable for ceiling mounting.
• Continuous or periodic exhaust ventilation
• For 12 V low-voltage motor fan connection
of bathroom, showers, kitchens and other utility PF1 press – 5-blade low-noise impeller to 220 V/50 Hz power mains use the step-down
spaces. with improved aerodynamics for higher transformer TRF 220/12-25 that is available upon
• Ventilation shaft mounting or duct connec- fan capacity. separate order.
tion. PF1 12 – modification with low-voltage
• Low to medium air flow motion for short dis- motor. 12 V AC power supply.
tances at low air resistance.
• Compatible with Ø 100, 125 and 150 mm air PF1T – equipped with a regulated timer
ducts. with the operating time from 2 to 30
minutes.

Accessories
Backdraft
Air ducts Grilles and hoods damper Speed controllers Clamps

110 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Aerodynamic characteristics

Air flow [m3/h] Air flow [m3/h] Air flow [m3/h]

Technical data

Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]
VENTS 100 PF1 50/60 220-240 14 0.085 2300 100 33 0.47
VENTS 100 PF1 turbo 50/60 220-240 16 0.1 2300 122 39 0.58
VENTS 100 PF1 press 50/60 220-240 16 0.1 2300 101 38 0.47
VENTS 100 PF1 12 50/60 12 14 1.5 2300 88 32 0.47
VENTS 125 PF1 50/60 220-240 16 0.1 2400 190 35 0.70
VENTS 125 PF1 turbo 50/60 220-240 24 0.105 2400 232 42 0.75
VENTS 125 PF1 press 50/60 220-240 24 0.105 2400 190 39 0.70
VENTS 125 PF1 12 50/60 12 16 1.7 2400 169 34 0.70
VENTS 150 PF1 50 220-240
VENTS 150 PF1 24 0.13 2400 299 38 0.84
60 220
(220 V/60 Hz)
VENTS 150 PF1 turbo 50 220-240
VENTS 150 PF1 turbo 29 0.13 2400 349 40 0.98
60 220
(220 V/60 Hz)
VENTS 150 PF1 press 50 220-240
VENTS 150 PF1 press 29 0.13 2400 309 38 0.84
60 220
(220 V/60 Hz)

VENTS 150 PF1 12 50 12 29 2 2400 267 37 0.84

Mounting example Overall dimensions

Dimensions [mm]
Model
ØD Ø D1 L L1
VENTS 100 PF1 100 141 128 13
VENTS 125 PF1 125 166 134 15
VENTS 150 PF1 150 188 146 15

Certificates

The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 111


AXIAL WALL- AND CEILING-MOUNTED FANS

VENTS S Design SVTH – equipped


with a pull cord
Series • Modern design and aesthetic look. switch, regulated
• The casing and the impeller are made of high- timer with the operating time adjustable from
quality durable ABS plastic, UV resistant. 2 to 30 minutes and a humidity sensor with the
operating threshold range from 60 to 90 %.
• The intellectual impeller design makes the fan
efficiency high and the service life long.
Control
• Ultra thin front panel.
Manual:
• Insect screen.
• The fan is controlled by a room light switch. It
• Protection rating IP34. is not included in the delivery package.
• The fan is controlled by the built-in pull cord
Motor switch V. Not applied in case of ceiling mounting.
• Reliable and low-watt electric motor. • Speed control is possible through a thyristor
speed controller (see Electrical Accessories).
• Designed for continuous operation and
Several fans may connected to the same controller.
requires no maintenance.
Speed controllers can not be connected to the
• Equipped with overheating protection. fans with T, TH, TP, VT, VTH modification.
Automatic:
Modifications and Options
• By the electronic control unit BU-1-60 (see
S1 – shortened flange model. Electrical Accessories). The control unit is supplied
S K – fan is equipped with a backdraft separately.
Axial fans
for exhaust ventilation damper for back flow preventing. • By the timer T (the built-in turn-off delay timer
enables the fan operation within 2 to 30 minutes
with the capacity up to 341 m3/h after the fan switching off ).
S L – the motor is equipped with ball
bearings for long service life (appr. 40 • By the humidity sensor and timer TH (if the
humidity level in the room exceeds the sensor
Application thousand hours) and fan mounting at
any angle. The bearings are maintenance-free and threshold adjustable value within 60-90 % the fan
• Continuous or periodic exhaust ventilation contain enough grease for the entire operating switches automatically on and operates until the
of bathroom, showers, kitchens and other utility period. humidity level drops to the standard level, after
spaces. that the fan continues operating within the time
S turbo – high-powered motor. period according to the timer setting, then shuts
• Ventilation shaft mounting or duct connec-
down).
tion.
• Low to medium air flow motion for short dis-
S 12 – modification with low-voltage Mounting features
tances at low air resistance.
• Compatible with Ø 100, 125 and 150 mm air
motor. 12 V AC power supply. • The fan is mounted directly into the ventilation
shaft.
ducts.
ST – equipped with a regulated timer • Flexible duct application is recommended in
with the operating time from 2 to 30 case of remote location of the ventilation shaft.
minutes. The air duct is connected to the fan exhaust flange
through a clamp.
STH – equipped with a timer
with the operating time from 2 • Fixed to wall by self-tapping screws.
to 30 minutes and a humidity • Suitable for ceiling mounting.
sensor with the threshold value from 60 to 90 %.
• For 12 V low-voltage motor fan connection
SV – equipped with a pull cord switch. to 220 V/50 Hz power mains use the step-down
transformer TRF 220/12-25 that is available upon
separate order.

SVT – equipped with a pull


cord switch and a regulated
timer with the operating time
adjustable from 2 to 30 minutes.

8 mm

Accessories
Backdraft
Air ducts Grilles and hoods damper Speed controllers Clamps

112 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Aerodynamic characteristics
Pressure, ΔP [Pa]

Pressure, ΔP [Pa]

Pressure, ΔP [Pa]
VENTS100 S VENTS125 S VENTS150 S
VENTS100 S turbo VENTS125 S turbo VENTS150 S turbo
VENTS100 S VENTS125 S VENTS150 S
(127-220 V/60 Hz) (127-220 V/60 Hz) (127-220 V/60 Hz)
VENTS100 S 12 VENTS125 S 12 VENTS150 S 12

Air flow [m3/h] Air flow [m3/h] Air flow [m3/h]

Technical data
Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]
VENTS 100 S 50/60 220-240 14 0.085 2300 95 34 0.58
VENTS 100 S turbo 50/60 220-240 16 0.1 2300 124 37 0.66
VENTS 100 S 127 10 0.115
(127-220 V/60 Hz) 60 2500 90 34 0.59
220 9 0.054
VENTS 100 S 12 50/60 12 14 1.5 2200 86 33 0.60
VENTS 125 S 50/60 220-240 16 0.1 2400 180 35 0.75
VENTS 125 S turbo 50/60 220-240 24 0.105 2400 226 37 0.78
VENTS 125 S 127 16 0.119
(127-220 V/60 Hz) 60 2400 185 36 0.76
220 15 0.102
VENTS 125 S 12 50/60 12 16 1.7 2300 165 34 0.78
VENTS 150 S 50 220-240
VENTS 150 S 24 0.13 2400 292 38 1.13
60 220
(220 V/60 Hz)
VENTS 150 S turbo 50 220-240
VENTS 150 S turbo 29 0.13 2400 341 40 1.13
60 220
(220 V/60 Hz)
VENTS 150 S 127 25 0.175
(127-220 V/60 Hz) 60 2350 267 38 1.13
220 25 0.388
VENTS 150 S 12 50 12 24 2 2300 260 37 1.13

Mounting example Overall dimensions


Dimensions [mm]
Model
ØD B H L L1
VENTS 100 S 100 150 120 108 12
VENTS 100 S1 100 150 120 93 12
VENTS 125 S 125 176 140 114 13
VENTS 125 S1 125 176 140 96 13
VENTS 150 S 150 205 165 132 14

Certificates

The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 113


AXIAL WALL- AND CEILING-MOUNTED FANS

VENTS D Design DVTH – equipped


with a pull cord
Series • Ultra slim front panel – only 6.5 mm. switch, regulated
• Modern design and aesthetic look. timer with the operating time adjustable from
2 to 30 minutes and a humidity sensor with the
• The casing and the impeller are made of high-
operating threshold range from 60 to 90 %.
quality durable ABS plastic, UV resistant.
• The intellectual impeller design makes the fan Control
efficiency high and the service life long.
Manual:
• Insect screen.
• The fan is controlled by a room light switch. It
• Protection rating IP34. is not included in the delivery set.
• The fan is controlled by the built-in V pull cord
Motor switch. Not applied in case of ceiling mounting.
• Reliable and low-watt electric motor. • Speed control is possible through a thyristor
speed controller (see Electrical Accessories).
• Designed for continuous operation and
Several fans may be connected to the same
requires no maintenance.
controller. Speed controllers can not be
• Equipped with overheating protection. connected to the fans with the T, TH, TP, VT, VTH
modifications.
Modifications and Options Automatic:
D1 – shortened spigot model. • By the BU-1-60 electronic control unit (see
D K – fan is equipped with a backdraft Electrical Accessories). The control unit is supplied
Axial fans separately.
for exhaust ventilation damper for back flow preventing.
with air capacity • By the T timer (the built-in turn-off delay timer
enables the fan operation within 2 to 30 minutes
up to 341 m3/h D L – the motor is equipped with ball after the fan switching off ).
bearings for long service life (appr. 40
thousand hours) and fan mounting at • By the humidity sensor and the TH timer (if
any angle. The bearings are maintenance-free and the humidity level in the room exceeds the sensor
Application threshold adjustable value within 60-90 %, the fan
contain enough grease for the entire operating
• Continuous or periodic exhaust ventilation period. switches automatically on and operates until the
of bathroom, showers, kitchens and other utility humidity level drops to the standard level, after
D turbo – high-powered motor. that the fan continues operating within the time
spaces.
period according to the timer setting, then shuts
• Ventilation shaft mounting or duct connec-
down).
tion.
D 12 – modification with low-voltage
• Low to medium air flow motion for short dis-
motor. 12 V AC power supply. Mounting features
tances at low air resistance.
• The fan is mounted directly into the ventilation
• Compatible with Ø 100, 125 and 150 mm air
DT – equipped with a regulated timer shaft.
ducts.
with the operating time from 2 to 30 • In case of remote location of the ventilation
minutes. shaft flexible air ducts may be used. The air duct
DTH – equipped with a timer is connected to the fan exhaust flange through a
with the operating time from 2 clamp.
to 30 minutes and a humidity • Fixed to the wall by means of screws.
sensor with the threshold value from 60 to 90 %. • Suitable for ceiling mounting.
DV – equipped with a pull cord switch. • To connect a fan with a 12 V low voltage motor
to 220 V/50 Hz power mains, it is necessary to
purchase a step-down transformer (e.g. the TRF
220/12-25 transformer).
DVT – equipped with a pull
cord switch and a regulated
timer with the operating time
adjustable from 2 to 30 minutes.

6.5 mm

Accessories
Backdraft
Air ducts Grilles and hoods damper Speed controllers Clamps

114 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Aerodynamic characteristics
Pressure, ΔP (Pa)

Pressure, ΔP (Pa)

Pressure, ΔP (Pa)
VENTS 100 D VENTS 125 D VENTS 150 D
VENTS 100 D turbo VENTS 125 D turbo VENTS 150 D turbo
VENTS 100 D VENTS 125 D VENTS 150 D
(127-220 V/60 Hz) (127-220 V/60 Hz) (127-220 V/60 Hz)
VENTS 100 D 12 VENTS 125 D 12 VENTS 150 D 12

Air flow [m3/h] Air flow [m3/h] Air flow [m3/h]

Technical data
Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]
VENTS 100 D 50/60 220-240 14 0.085 2300 95 34 0.58
VENTS 100 D turbo 50/60 220-240 16 0.1 2300 124 37 0.66
VENTS 100 D 127 10 0.115
(127-220 V/60 Hz) 60 2500 90 34 0.59
220 9 0.054
VENTS 100 D 12 50/60 12 14 1.5 2200 86 33 0.60
VENTS 125 D 50/60 220-240 16 0.1 2400 180 35 0.74
VENTS 125 D turbo 50/60 220-240 24 0.105 2400 226 37 0.81
VENTS 125 D 127 16 0.119
(127-220 V/60 Hz) 60 2400 185 36 0.75
220 15 0.102
VENTS 125 D 12 50/60 12 16 1.7 2300 165 34 0.69
VENTS 150 D 50 220-240
VENTS 150 D 24 0.13 2400 292 38 0.92
60 220
(220 V/60 Hz)
VENTS 150 D turbo 50 220-240
VENTS 150 D turbo 29 0.13 2400 341 40 1.06
60 220
(220 V/60 Hz)
VENTS 150 D 127 25 0.175
(127-220 V/60 Hz) 60 2350 267 38 0.93
220 25 0.388

VENTS 150 D 12 50 12 29 2 2300 260 37 0.88

Mounting example Overall dimensions


Dimensions [mm]
Model
ØD B H L L1
VENTS 100 D 100 150 120 108.5 12.5
VENTS 100 D1 100 150 120 93 12.5
VENTS 125 D 125 176 140 114 12.5
VENTS 125 D1 125 176 140 96 12.5
VENTS 150 D 150 205 165 132 13

Certificates

The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 115


AXIAL WALL- AND CEILING-MOUNTED FANS

VENTS IFK Application Control


Series • Continuous or periodic exhaust ventilation Manual:
of bathrooms, showers, kitchens and and utility
spaces.
• The fan is controlled by a room light switch.
• It is not included in the delivery.
• Ventilation shaft mounting or connection to Ø
Automatic:
125 mm air ducts.
• Low to medium air flow motion for short dis- • Speed control with a an electronic control unit
tances at low air resistance. BU-1-60, refer to the Electric accessories.
• The control unit is available upon separate or-
der.
Design
• Modern design and aesthetic look.
Mounting features
• The casing and the impeller are made of high-
• The fan is mounted directly into the ventila-
quality durable ABS plastic, UV resistant.
tion shaft.
• The fan is delivered with a safe low-voltage • Flexible duct connection is recommended in
motor of 12 V (transformer power unit 220 / 12 V is
included in the delivery). case of the remote ventilation shaft location.

• Reliable motor on ball bearings with minimum • The air duct is connected to the fan exhaust
energy demand up to 5 W. flange through a clamp.

• Protection rating IP24 • Fixing to wall with screws.


Axial fans for exhaust ventilation • Suitable for ceiling mounting.
with air flow Motor
up to 82 m3/h
• Reliable motor with low energy demand.
• Designed for continuous operation and re-
quires no maintenance.
• The motor is equipped with overheating pro-
tection for 72 hours.

Aerodynamic characteristics Overall dimensions


45

40
VENTS 125 IFK
35

30

25

20
Dimensions [mm]
15
Model
Ø D Ø D1 L L1
10 VENTS 125 IFK 125 166 55 13.5
5

0
0 10 20 30 40 50 60 70 80 90 100
Air flow [m3/h]

Technical data

Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m. IP
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]

VENTS 125 IFK 50/60 220 5 0.048 2300 82 35 0.44 IP24

Accessories

Air ducts Grilles and hoods Back valves Speed controllers Clamps

116 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


VENTS IFT Application Control
Series • Continuous or periodic exhaust ventilation Manual:
of bathrooms, showers, kitchens and and utility
spaces.
• The fan is controlled by a room light switch.
• It is not included in the delivery.
• Ventilation shaft mounting or connection to
Automatic:
Ø 125 mm air ducts.
• Low to medium air flow motion for short • Speed control with a an electronic control
distances at low air resistance. unit BU-1-60, refer to the Electric accessories.
• The control unit is available upon separate
order.
Design
• Modern design and aesthetic look.
Mounting features
• The casing and the impeller are made of high-
• The fan is mounted directly into the
quality durable ABS plastic, UV resistant.
ventilation shaft.
• The fan is delivered with a safe low-voltage • Flexible duct connection is recommended in
motor of 12 V (transformer power unit 220 / 12 V
is included in the delivery). case of the remote ventilation shaft location.

• Reliable motor on ball bearings with • The air duct is connected to the fan exhaust
minimum energy demand up to 5 W. flange through a clamp.

• Protection rating IP24 • Fixing to wall with screws.


Axial fans for exhaust ventilation • Suitable for ceiling mounting.
with air flow Motor
up to 78 m3/h
• Reliable motor with low energy demand.
• Designed for continuous operation and
requires no maintenance.
• The motor is equipped with overheating
protection for 72 hours.

Aerodynamic characteristics Overall dimensions


40

35
VENTS 125 IFT
30

25

20

Dimensions [mm]
15 Model
ØD B H L L1
10
VENTS 125 IFT 125 193 188 67 18
5

0
0 10 20 30 40 50 60 70 80 90 100
Air flow [m3/h]

Technical data

Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m. IP
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]

VENTS 125 IFT 50/60 220 5 0.049 2200 78 34 0.49 IP24

Accessories

Air ducts Grilles and hoods Back valves Speed controllers Clamps

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 117


AXIAL WALL- AND CEILING-MOUNTED FANS

VENTS IFP Application Control


Series • Continuous or periodic exhaust ventilation Manual:
of bathrooms, showers, kitchens and and utility
spaces.
• The fan is controlled by a room light switch.
• It is not included in the delivery.
• Ventilation shaft mounting or connection to Ø
Automatic:
125 mm air ducts.
• Low to medium air flow motion for short dis- • Speed control with a an electronic control unit
tances at low air resistance. BU-1-60, refer to the Electric accessories.
• The control unit is available upon separate or-
der.
Design
• Modern design and aesthetic look.
Mounting features
• The casing and the impeller are made of high-
• The fan is mounted directly into the ventila-
quality durable ABS plastic, UV resistant.
tion shaft.
• The fan is delivered with a safe low-voltage • Flexible duct connection is recommended in
motor of 12 V (transformer power unit 220 / 12 V is
included in the delivery). case of the remote ventilation shaft location.

• Reliable motor on ball bearings with minimum • The air duct is connected to the fan exhaust
energy demand up to 5 W. flange through a clamp.

• Protection rating IP24 • Fixing to wall with screws.


Axial fans for exhaust ventilation
with air flow
• Suitable for ceiling mounting.

up to 80 m3/h Motor
• Reliable motor with low energy demand.
• Designed for continuous operation and re-
quires no maintenance.
• The motor is equipped with overheating pro-
tection for 72 hours.

Aerodynamic characteristics Overall dimensions


40

35
VENTS 125 IFP
30

25

20

Dimensions [mm]
15 Model
ØD B L L1
10
VENTS 125 IFP 125 186 59 15
5

0
0 10 20 30 40 50 60 70 80 90 100
Air flow [m3/h]

Technical data

Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m. IP
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]

VENTS 125 IFP 50/60 220 5 0.048 2285 80 35 0.5 IP24

Accessories

Air ducts Grilles and hoods Back valves Speed controllers Clamps

118 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


VENTS. Domestic ventilation. Catalogue №6 | 02-2020 119
AXIAL DECORATIVE FANS

Axial decorative fans


VENTS LD, VENTS LD Auto, VENTS LD light Series page

Air flow up to 345 m3/h 122

Axial decorative fans


VENTS LD Fresh Time Series page
Air flow up to 115 m /h
3 128

Axial decorative fans


VENTS Modern, VENTS Modern Auto Series page
Air flow up to 345 m /h
3 130

Axial decorative fans


VENTS Domino Series page
Air flow up to 310 m3/h 134

Axial decorative fans


VENTS Z Series page
Air flow up to 358 m /h
3 136

Axial decorative fans


VENTS Z Star Series page

Air flow up to 358 m3/h 138

120 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Axial decorative fans
VENTS Vitro Series page

Air flow up to 358 m /h


3 140

Axial decorative fans


VENTS Vitro Star Series page

Air flow up to 358 m /h


3 142

Axial decorative fans


VENTS X Series, VENTS X Star Series page
Air flow up to 302 m /h 3
144

Axial decorative fans


VENTS Lumis Series page

Air flow up to 115 m /h3 148

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 121


AXIAL DECORATIVE FANS

VENTS LD Design LDVT – equipped with a pull


cord switch and a regulated
Series • Modern design and aesthetic look. timer with the operating time
• The casing and the impeller are made of high- adjustable from 2 to 30 minutes.
quality durable ABS plastic, UV resistant. LDVTH – equipped
• Various decorative plates for the front panel of with a pull cord
the natural aluminum. switch, regulated
timer with the operating time adjustable from
• The intellectual impeller design makes the fan 2 to 30 minutes and a humidity sensor with the
efficiency high and the service life long.
operating threshold range from 60 to 90 %.
• Protection rating IP34.
Control
Motor
Manual:
• Reliable and low-watt electric motor.
• The fan is controlled by a room light switch. It
• Designed for continuous operation and is not included in the delivery set.
requires no maintenance.
• The fan is controlled by the built-in pull cord
• Equipped with overheating protection. switch V. Not applied in case of ceiling mounting.
• Speed control is possible through a thyristor
Modifications and Options speed controller (see Electrical Accessories).
Axial decorative fans Several fans may be connected to the same
LDA – the fan with a ground alumunium front
for exhaust ventilation with air panel.
controller. Speed controllers can not be connected
capacity up to 310 m3/h to the fans with T, TH, TP, VT, VTH modifications.
LDA gold – the fan with a gold-tinted aluminium
Automatic:
front panel.
Application LDA chrome – the fan with a mirror finish • By the BU-1-60 electronic control unit (see
Electrical Accessories). The control unit is supplied
aluminium front panel.
separately.
• Continuous or periodic exhaust ventilation LD alumat – the fan with a front panel painted
of bathroom, showers, kitchens and other utility silver (matt). • By the T timer (the built-in turn-off delay timer
spaces. enables the fan operation within 2 to 30 minutes
LD alulak – the fan with a front panel painted after the fan switching off ).
• Ventilation shaft mounting or duct connec- silver (gloss).
tion.
LD1 – shortened branch pipe model.
• By the humidity sensor and the TH timer (if the
humidity level in the room exceeds the sensor
• Low to medium air flow motion for short dis-
LD K – fan is equipped with a backdraft threshold adjustable value within 60-90 % the fan
tances at low air resistance.
damper for back flow preventing. switches automatically on and operates until the
• Compatible with Ø 100, 125 and 150 mm air humidity level drops to the standard level, after
ducts. that the fan continues operating within the time
LD L – the motor is equipped with ball period according to the timer setting, then shuts
bearings for long service life (appr. 40 down).
thousand hours) and fan mounting at
any angle. The bearings are maintenance-free and Mounting features
contain enough grease for the entire operating
period. • The fan is mounted directly into the ventilation
shaft.
LD turbo – high-powered motor.
• In case of remote location of the ventilation
LDA shaft flexible air ducts may be used. The air duct
is connected to the fan exhaust flange through a
LD 12 – modification with low-voltage clamp.
motor. 12 V AC power supply.
• Fixed to the wall by means of screws.
LDA chrome • Suitable for ceiling mounting.
LDT – equipped with a regulated timer
with the operating time from 2 to 30
• To connect a fan with a 12 V low voltage motor
to 220 V/50 Hz power mains, it is necessary to
minutes. purchase a step-down transformer (e.g. the TRF
LDA gold LDTH – equipped with a timer 220/12-25 transformer).
with the operating time from 2
to 30 minutes and a humidity
sensor with the threshold value from 60 to 90 %.
LD alulak LDV – equipped with a pull cord switch.

LD alumat

Accessories
Backdraft
Air ducts Grilles and hoods damper Speed controllers Clamps

122 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Aerodynamic characteristics
Pressure, ΔP [Pa]

Pressure, ΔP [Pa]

Pressure, ΔP [Pa]
VENTS100 LD VENTS125 LD VENTS150 LD
VENTS100 LD turbo VENTS125 LD turbo VENTS150 LD turbo
VENTS100 LD VENTS125 LD VENTS150 LD
(127-220 V/60 Hz) (127-220 V/60 Hz) (127-220 V/60 Hz)
VENTS100 LD 12 VENTS125 LD 12 VENTS150 LD 12

Air flow [m3/h] Air flow [m3/h] Air flow [m3/h]

Technical data
Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]
VENTS 100 LD 50/60 220-240 14 0.085 2300 88 33 0.60
VENTS 100 LD turbo 50/60 220-240 16 0.1 2300 115 36 0.68
VENTS 100 LD 127 10 0.115
(127-220 V/60 Hz) 60 2500 82 33 0.60
220 9 0.054
VENTS 100 LD 12 50/60 12 14 1.5 2200 77 32 0.59
VENTS 125 LD 50/60 220-240 16 0.1 2400 167 34 0.74
VENTS 125 LD turbo 50/60 220-240 24 0.105 2400 209 36 0.84
VENTS 125 LD 127 16 0.119
(127-220 V/60 Hz) 60 2400 172 35 0.74
220 15 0.102
VENTS 125 LD 12 50/60 12 16 1.7 2300 149 33 0.72
VENTS 150 LD 50 220-240
VENTS 150 LD 24 0.13 2400 265 37 0.96
60 220
(220 V/60 Hz)
VENTS 150 LD turbo 50 220-240
VENTS 150 LD turbo 29 0.13 2400 310 39 1.10
60 220
(220 V/60 Hz)
VENTS 150 LD 127 25 0.175
(127-220 V/60 Hz) 60 2350 240 37 0.96
220 25 0.388

VENTS 150 LD 12 50 12 29 2 2300 236 36 0.92

Mounting example Overall dimensions

Dimensions [mm]
Model
ØD B H L L1
VENTS 100 LD 100 152 120 126 30
VENTS 100 LD1 100 152 120 111 30
VENTS 125 LD 125 177 140 135 34
VENTS 125 LD1 125 177 140 116 34
VENTS 150 LD 150 206 165 154 36

Certificates

The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 123


AXIAL DECORATIVE FANS

VENTS LD Auto Design Control


Series • Modern design and aesthetic look. Manual:
• The casing, impeller and front panel are made • The fan is controlled with a room light switch
of high-quality and durable UV-resistant ABS (not included into delivery set).
plastic.
• The fan is controlled with a built-in pull cord
• Various decorative natural aluminium plates. switch "V". This option is not applicable for ceiling
mounting.
• The thermal actuator provides smooth
opening and closing of the automatic louvre Automatic:
shutters that prevent air back drafting.
• Speed control with a an electronic control unit
• The impeller design enhances the fan BU-1-60, refer Electric accessories. The control
efficiency and prolongs the motor service life. unit is available upon separate order.
• Protection rating IP24. • Fan control with a turn-off delay timer "T" that
enables fan running from 2 to 30 minutes after
Motor turning the fan off.
• Fan control with a humidity sensor and turn-
• Reliable motor with low energy demand off delay timer "TH" that enables fan switching
• Designed for continuous operation and on and running until the indoor humidity drops
requires no maintenance. below the set point adjustable from 60 to 90  %
and subsequent fan running within the set time
• Equipped with overheating protection.
before turning off.
Exhaust axial decorative fans with
automatic louvre shutters with air Modifications and options
Mounting features
flow up to 345 m3/h LD Auto L – the motor is equipped with
ball bearings for long service life (appr. • The fan is mounted directly into the ventilation
40 thousand hours) and fan mounting at shaft.
Application any angle. The bearings are maintenance-free and • Flexible duct connection is recommended in
contain enough grease for the entire operating case of the remote ventilation shaft location. The
• Continuous or periodic exhaust ventilation period. air duct is connected to the fan exhaust flange
of bathroom, showers, kitchens and other utility
spaces. LD Auto turbo – high-powered motor. through a clamp.

• Ventilation shaft mounting or duct connec- • Fixing with screws.


tion. • Suitable for ceiling mounting.
• Low to medium air flow motion for short dis- LD Auto press – 5-blade low-noise
impeller with improved aerodynamics
• The step-down transformer (TRF 220/12-25)
tances at low air resistance. enables connection of a low-voltage fan 12 V/50
for higher fan capacity. Hz to 220 V/50 Hz power mains. Available upon
• Compatible with Ø 100, 125 and 150 mm air LD Auto 12 – equipped with a reliable separate order.
ducts.
low-voltage motor, 12 V.

LD Auto T – equipped with a turn-


off delay timer adjustable from 2 to 30
minutes.
LD Auto TH – equipped
with a turn-off delay timer
adjustable from 2 to 30
minutes and a humidity sensor adjustable from
60 to 90 %.
LD Auto V – equipped with a pull cord
switch.
Fan off – louver Fan on – louver
shutters CLOSED shutters OPEN

LD Auto VT – equipped with


a pull cord switch and a turn-
off delay timer adjustable
from 2 to 30 minutes.
LD Auto VTH –
equipped with a pull
cord switch, turn-off
delay timer adjustable from 2 to 30 minutes and a
humidity sensor adjustable from 60 to 90 %.
LDA Auto LDA Auto LDA Auto
Chrome Gold

Accessories
Air ducts Grilles and hoods Back valves Speed controllers Control unit Transformer Clamps

124 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Aerodynamic characteristics

VENTS 100 LD Auto VENTS 125 LD Auto VENTS 150 LD Auto


VENTS 100 LD Auto turbo VENTS 125 LD Auto turbo VENTS 150 LD Auto turbo
VENTS 100 LD Auto press VENTS 125 LD Auto press VENTS 150 LD Auto press
VENTS 100 LD Auto 12 VENTS 125 LD Auto 12 VENTS 150 LD Auto 12

Air flow [m3/h] Air flow [m3/h] Air flow [m3/h]

Technical data

Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]

VENTS 100 LD Auto 50/60 220-240 18 0.085 2300 98 34 0.73


VENTS 100 LD Auto turbo 50/60 220-240 20 0.1 2300 128 37 0.79
VENTS 100 LD Auto press 50/60 220-240 20 0.1 2300 99 37 0.73
VENTS 100 LD Auto 12 50/60 12 18 1.5 2200 86 33 0.72
VENTS 125 LD Auto 50/60 220-240 22 0.1 2400 185 35 0.83
VENTS 125 LD Auto turbo 50/60 220-240 29 0.13 2400 232 37 0.89
VENTS 125 LD Auto press 50/60 220-240 29 0.13 2400 188 39 0.83
VENTS 125 LD Auto 12 50/60 12 22 1.7 2300 165 34 0.82
VENTS 150 LD Auto 50 220-240
VENTS 150 LD Auto 26 0.13 2400 295 39 1.14
60 220
(220 V/60 Hz)
VENTS 150 LD Auto turbo 50 220-240
VENTS 150 LD Auto turbo 32 0.13 2400 345 41 1.2
60 220
(220 V/60 Hz)
VENTS 150 LD Auto press 50 220-240
VENTS 150 LD Auto press 32 0.14 2400 307 41 1.14
60 220
(220 V/60 Hz)

VENTS 150 LD Auto 12 50 12 29 2 2300 263 38 1.13

Mounting example Overall dimensions

Dimensions [mm]
Model
ØD B L L1
VENTS 100 LD Auto 99.5 205 110 60
VENTS 125 LD Auto 125 205 118 65
VENTS 150 LD Auto 150 240 137 81

L
L1
D

Certificates

The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 125


AXIAL DECORATIVE FANS

VENTS LD light Design Control


Series • Modern design and original look. Manual:
• The casing and the impeller are made of high- • The fan is controlled with a room light switch
quality durable ABS plastic, UV resistant. (not included into delivery set).
• Front panel edge is made of transparent • The fan is controlled with a built-in pull cord
plexiglass with LED illumination of various colours switch "V". This option is not applicable for ceiling
(blue, red, green). mounting.
• The impeller design enhances the fan • Speed control is possible through a thyristor
efficiency and prolongs the motor service life. speed controller (see Electrical Accessories).
Several fans may connected to the same controller.
• Protection rating IP34.
Speed controllers can not be connected to the
fans with T, TH, TP, VT, VTH modification.
Motor
Automatic:
• Reliable motor with low energy demand.
• Speed control with a an electronic control
• Designed for continuous operation and unit BU-1-60, refer the Electric accessories.
requires no maintenance. The control unit is available upon separate order.
• Equipped with overheating protection. • Fan control with a turn-off delay timer "T" that
enables fan running from 2 to 30 minutes after
Modifications and options turning the fan off.
Exhaust axial decorative fans with air LD Light K – the fan is equipped with a
• Fan control with a humidity sensor and turn-
off delay timer "TH" that enables fan switching
flow up to 310 m3/h back valve to prevent air backdrafting. on and running until the indoor humidity drops
below the set point adjustable from 60 to 90  %
LD Light L – the motor is equipped with and subsequent fan running within the set time
Application before turning off.
ball bearings for long service life (appr.
• Continuous or periodic exhaust ventilation 40 thousand hours) and fan mounting at
of bathroom, showers, kitchens and other utility any angle. The bearings are maintenance-free and Mounting features
spaces. contain enough grease for the entire operating
• Ventilation shaft mounting or duct connec- period. • The fan is mounted directly into the ventilation
shaft.
tion. LD Light turbo – high-powered motor.
• Low to medium air flow motion for short dis- • Flexible duct connection is recommended in
case of the remote ventilation shaft location. The
tances at low air resistance.
air duct is connected to the fan exhaust flange
• Compatible with Ø 100, 125 and 150 mm air LD Light T – equipped with a turn- through a clamp.
ducts. off delay timer adjustable from 2 to 30 • Fixing to wall with screws.
minutes.
• Suitable for ceiling mounting.
LD Light TH – equipped
with a turn-off delay timer
adjustable from 2 to 30
minutes and a humidity sensor adjustable from
60 to 90 %.
LD Light V – equipped with a pull cord
switch.

LD Light VT – equipped with


LD Light blue a pull cord switch and a turn-
off delay timer adjustable
from 2 to 30 minutes.
LD Light VTH –
equipped with a pull
cord switch, turn-off
delay timer adjustable from 2 to 30 minutes and a
LD Light red humidity sensor adjustable from 60 to 90 %.

Accessories
Air ducts Grilles and hoods Back valves Speed controllers Control unit Transformer Clamps

126 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Aerodynamic characteristics
Pressure, ΔP [Pa]

Pressure, ΔP [Pa]

Pressure, ΔP [Pa]
VENTS 100 LD Light VENTS 125 LD Light VENTS 150 LD Light
VENTS 100 LD Light turbo VENTS 125 LD Light turbo VENTS 150 LD Light turbo
VENTS 100 LD Light 12 VENTS 125 LD Light 12 VENTS 150 LD Light 12

Air flow [m3/h] Air flow [m3/h] Air flow [m3/h]

Technical data

Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]

VENTS 100 LD Light 50/60 220-240 14 0.085 2300 88 33 0.73


VENTS 100 LD Light turbo 50/60 220-240 16 0.1 2300 115 36 0.81
VENTS 125 LD Light 50/60 220-240 16 0.1 2400 167 34 0.89
VENTS 125 LD Light turbo 50/60 220-240 24 0.105 2400 209 36 0.99
VENTS 150 LD Light 50 220-240
VENTS 150 LD Light 24 0.13 2400 265 37 1.14
60 240
(220 V/60 Hz)
VENTS 150 LD Light turbo 50 220-240
VENTS 150 LD Light turbo 29 0.13 2400 310 39 1.28
60 220
(220 V/60 Hz)

Mounting example Overall dimensions

Overall dimensions [mm]


Model
ØD B L L1
VENTS 100 LD Light 99.5 160 126 96
VENTS 125 LD Light 125 187 135 101
VENTS 150 LD Light 150 216 154 118

L
L1
D

Certificates

The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 127


AXIAL DECORATIVE FANS

VENTS LD Fresh time Design LDVT Fresh time – equipped


with a pull cord switch and
Series • A battery-powered quartz clock is built into a regulated timer with the
the fan casing. operating time adjustable from 2 to 30 minutes.
• Both Arabic and Roman hour plates are LDVTH Fresh
available on the front panel. time – equipped
• Modern design and aesthetic look. with a pull cord
switch, regulated timer with the operating time
• The casing and the impeller are made of high-
adjustable from 2 to 30 minutes and a humidity
quality durable ABS plastic, UV resistant.
sensor with the operating threshold range from
• The intellectual impeller design makes the fan 60 to 90 %.
efficiency high and the service life long.
• Protection rating IP34. Control
Manual:
Motor
• The fan is controlled by a room light switch. It
• Reliable and low-watt electric motor. is not included in the delivery package.
• Designed for continuous operation and • Speed control is possible through a thyristor
requires no maintenance. speed controller (see Electrical Accessories).
• Equipped with overheating protection. Several fans may connected to the same controller.
Speed controllers can not be connected to the
fans with T, TH, TP, VT, VTH modification.
Axial fans Modifications and Options
for exhaust ventilation Automatic:
LD Fresh time R – fan with a Roman hour plate.
with a built-in clock and capacity
LD Fresh time K – fan is equipped
• By the electronic control unit BU-1-60 (see
up to 310 m3/h Electrical Accessories). The control unit is supplied
with a backdraft damper for back flow separately.
preventing.
LD Fresh time L – the motor is
• By the timer T (the built-in turn-off delay timer
Application enables the fan operation within 2 to 30 minutes
equipped with ball bearings for long after the fan switching off ).
• Continuous or periodic exhaust ventilation service life (appr. 40 thousand hours)
• By the humidity sensor and timer TH (if the
of bathroom, showers, kitchens and other utility and fan mounting at any angle. The bearings are
humidity level in the room exceeds the sensor
spaces. maintenance-free and contain enough grease for
threshold adjustable value within 60-90 % the fan
the entire operating period.
• Ventilation shaft mounting or duct connec- switches automatically on and operates until the
tion. LD Fresh time turbo – high-powered humidity level drops to the standard level, after
motor.
• Low to medium air flow motion for short dis- that the fan continues operating within the time
tances at low air resistance. period according to the timer setting, then shuts
down).
• Compatible with Ø 100, 125, 150 mm air LD Fresh time 12 – modification with
ducts. low-voltage motor. 12 V AC power
supply. Mounting features
LDT Fresh time – equipped with a • The fan is mounted directly into the ventilation
regulated timer with the operating time shaft.
from 2 to 30 minutes. • Flexible duct application is recommended in
LDTH Fresh time – case of remote location of the ventilation shaft.
equipped with a timer The air duct is connected to the fan exhaust flange
with the operating time through a clamp.
from 2 to 30 minutes and a humidity sensor • Fixed to wall by self-tapping screws.
with the threshold value from 60 to 90 %.
• For 12 V low-voltage motor fan connection
LDV Fresh time – equipped with a pull to 220 V/50 Hz power mains use the step-down
cord switch. transformer TRF 220/12-25 that is available upon
separate order.

Accessories
Backdraft
Air ducts Grilles and hoods damper Speed controllers Clamps

128 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Aerodynamic characteristics

Air flow [m3/h] Air flow [m3/h] Air flow [m3/h]

Technical data

Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]

VENTS 100 LD Fresh time 50/60 220-240 14 0.085 2300 88 33 0.60


VENTS 100 LD Fresh time turbo 50/60 220-240 16 0.1 2300 115 36 0.68
VENTS 100 LD Fresh time 12 50/60 12 14 1.5 2200 77 32 0.59
VENTS 125 LD Fresh time 50/60 220-240 16 0.1 2400 167 34 0.74
VENTS 125 LD Fresh time turbo 50/60 220-240 24 0.105 2400 209 36 0.84
VENTS 125 LD Fresh time 12 50/60 12 16 1.7 2300 149 33 0.72
VENTS 150 LD Fresh time 50 220-240
VENTS 150 LD Fresh time 24 0.13 2400 265 37 0.96
60 220
(220 V/60 Hz)
VENTS 150 LD Fresh time turbo 50 220-240
VENTS 150 LD Fresh time turbo 30 0.13 2400 310 39 1.10
60 220
(220 V/60 Hz)

VENTS 150 LD Fresh time 12 50 12 29 2 2300 236 36 0.92

Mounting example Overall dimensions

Dimensions [mm]
Model
ØD B H L L1
VENTS 100 LD Fresh time 100 152 120 135 40
VENTS 125 LD Fresh time 125 175 140 145 44
VENTS 150 LD Fresh time 150 205 165 164 46

Certificates

The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 129


AXIAL DECORATIVE FANS

VENTS Modern Design Control


Series • Modern design and aesthetic look. Manual:
• The casing and the impeller are made of high- • The fan is controlled by a room light switch. It
quality durable ABS plastic, UV resistant. is not included in the delivery package.
• The front panel from organic glass. • The fan is controlled by the built-in pull cord
switch V. Not applied in case of ceiling mounting.
• The intellectual impeller design makes the fan
efficiency high and the service life long. • Speed control is possible through a thyristor
speed controller (see Electrical Accessories).
• Protection rating IP34.
Several fans may connected to the same controller.
Speed controllers can not be connected to the
Motor fans with T, TH, TP, VT, VTH modification.
• Reliable and low-watt electric motor. Automatic:
• Designed for continuous operation and • By the electronic control unit BU-1-60 (see
requires no maintenance. Electrical Accessories). The control unit is supplied
separately.
• Equipped with overheating protection.
• By the timer T (the built-in turn-off delay timer
Modifications and Options enables the fan operation within 2 to 30 minutes
after the fan switching off ).
Modern K – fan is equipped with
Axial fans
a backdraft damper for back flow
• By the humidity sensor and timer TH (if the
for exhaust ventilation humidity level in the room exceeds the sensor
preventing. threshold adjustable value within 60-90 % the fan
with the capacity up to 310 m3/h Modern L – the motor is equipped with switches automatically on and operates until the
ball bearings for long service life (appr. humidity level drops to the standard level, after
40 thousand hours) and fan mounting at that the fan continues operating within the time
Application any angle. The bearings are maintenance-free and period according to the timer setting, then shuts
• Continuous or periodic exhaust ventilation contain enough grease for the entire operating down).
of bathroom, showers, kitchens and other utility period.
spaces. Modern turbo – high-powered motor. Mounting features
• Ventilation shaft mounting or duct connec- • The fan is mounted directly into the ventilation
tion. shaft.
• Low to medium air flow motion for short dis- Modern 12 – modification with low- • Flexible duct application is recommended in
tances at low air resistance. voltage motor. 12 V AC power supply. case of remote location of the ventilation shaft.
The air duct is connected to the fan exhaust flange
• Compatible with Ø 100, 125 and 150 mm air through a clamp.
ducts. Modern T – equipped with a regulated
timer with the operating time from 2 to • Fixed to wall by self-tapping screws.
30 minutes. • Suitable for ceiling mounting.
Modern TH – equipped with • For 12 V low-voltage motor fan connection
a timer with the operating to 220 V/50 Hz power mains use the step-down
time from 2 to 30 minutes and transformer TRF 220/12-25 that is available upon
a humidity sensor with the threshold value from separate order.
60 to 90 %.
Modern V – equipped with a pull cord
switch.

Modern VT – equipped  with


a pull cord switch and a
regulated timer with the
operating time adjustable from 2 to 30 minutes.
Modern VTH –
equipped with a
pull cord switch,
regulated timer with the operating time adjustable
from 2 to 30 minutes and a humidity sensor with
the operating threshold range from 60 to 90 %.

Accessories
Backdraft
Air ducts Grilles and hoods damper Speed controllers Clamps

130 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Aerodynamic characteristics

Air flow [m3/h] Air flow [m3/h] Air flow [m3/h]

Technical data

Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]

VENTS 100 Modern 50/60 220-240 14 0.085 2300 88 33 0.60


VENTS 100 Modern turbo 50/60 220-240 16 0.1 2300 115 36 0.68
VENTS 100 Modern 12 50/60 12 14 1.5 2200 77 32 0.59
VENTS 125 Modern 50/60 220-240 16 0.1 2400 167 34 0.74
VENTS 125 Modern turbo 50/60 220-240 24 0.105 2400 209 36 0.84
VENTS 125 Modern 12 50/60 12 16 1.7 2300 149 33 0.72
VENTS 150 Modern 50/60 220-240
VENTS 150 Modern 24 0.13 2400 265 37 0.96
60 220
(220 V/60 Hz)
VENTS 150 Modern turbo 50 220-240
VENTS 150 Modern turbo 29 0.13 2400 310 39 1.10
60 220
(220 V/60 Hz)

VENTS 150 Modern 12 50 12 29 2 2300 236 36 0.92

Mounting example Overall dimensions

Dimensions [mm]
Model
ØD B L L1
VENTS 100 Modern 100 170 130 35
VENTS 125 Modern 125 196 139 38
VENTS 150 Modern 150 226 157 39

Certificates

The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 131


AXIAL DECORATIVE FANS

VENTS Modern Auto Design Control


Series • Modern design and aesthetic look. Manual:
• The casing and the impeller are made of high- • The fan is controlled with a room light switch
quality durable ABS plastic, UV resistant. (not included into delivery set).
• Front panel is made of white or black organic • The fan is controlled with a built-in pull cord
glass. switch "V". This option is not applicable for ceiling
mounting.
• The fan and motor are specially designed for
silent operation. Automatic:
• The impeller design enhances the fan • Speed control with a an electronic control unit
efficiency and prolongs the motor service life. BU-1-60, refer Electric accessories. The control
unit is available upon separate order.
• Protection rating IP24
• Fan control with a turn-off delay timer "T" that
Motor enables fan running from 2 to 30 minutes after
turning the fan off.
• Reliable motor with low energy demand
• Fan control with a humidity sensor and turn-
• Designed for continuous operation and off delay timer "TH" that enables fan switching
requires no maintenance. on and running until the indoor humidity drops
below the set point adjustable from 60 to 90  %
• Equipped with overheating protection.
and subsequent fan running within the set time
before turning off.
Exhaust axial decorative fans with Modifications and options
automatic louvre shutters with air Modern Auto L – the motor is Mounting features
flow up to 345 m3/h equipped with ball bearings for long
service life (appr. 40 thousand hours) • The fan is mounted directly into the ventilation
and fan mounting at any angle. The bearings are shaft.
Application maintenance-free and contain enough grease for • Flexible duct connection is recommended in
the entire operating period. case of the remote ventilation shaft location. The
• Continuous or periodic exhaust ventilation air duct is connected to the fan exhaust flange
of bathroom, showers, kitchens and other utility Modern Auto turbo – high-powered
spaces. motor. through a clamp.

• Ventilation shaft mounting or duct connec- • Fixing with screws.


tion. Modern Auto press – 5-blade
low-noise impeller with improved
• Suitable for ceiling mounting.
• Low to medium air flow motion for short dis- aerodynamics for higher fan capacity. • The step-down transformer (TRF 220/12-25)
tances at low air resistance. enables connection of a low-voltage fan 12 V/50
Modern Auto 12 – equipped with a Hz to 220 V/50 Hz power mains. Available upon
• Compatible with Ø 100, 125 and 150 mm air reliable low-voltage motor, 12 V. separate order.
ducts.

Modern Auto T – equipped with a


turn-off delay timer adjustable from 2 to
30 minutes.
Modern Auto TH –
equipped with a turn-off delay
timer adjustable from 2 to 30
minutes and a humidity sensor adjustable from 60
to 90 %.
Modern Auto V – equipped with a pull
cord switch.

Fan off – louver shutters CLOSED


Modern Auto VT – equipped
with a pull cord switch and a
turn-off delay timer adjustable
from 2 to 30 minutes.
Modern Auto VTH –
equipped with a pull
cord switch, turn-off
delay timer adjustable from 2 to 30 minutes and a
humidity sensor adjustable from 60 to 90 %.

Fan on – louver shutters OPEN

Accessories
Air ducts Grilles and hoods Back valves Speed controllers Control unit Transformer Clamps

132 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Aerodynamic characteristics

VENTS 100 Modern Auto VENTS 125 Modern Auto VENTS 150 Modern Auto
VENTS 100 Modern Auto turbo VENTS 125 Modern Auto turbo VENTS 150 Modern Auto turbo
VENTS 100 Modern Auto press VENTS 125 Modern Auto press VENTS 150 Modern Auto press
VENTS 100 Modern Auto 12 VENTS 125 Modern Auto 12 VENTS 150 Modern Auto 12

Air flow [m3/h] Air flow [m3/h] Air flow [m3/h]

Technical data

Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]

VENTS 100 Modern Auto 50/60 220-240 18 0.085 2300 98 34 0.85


VENTS 100 Modern Auto turbo 50/60 220-240 20 0.1 2300 128 37 0.90
VENTS 100 Modern Auto press 50/60 220-240 20 0.1 2300 99 37 0.85
VENTS 100 Modern Auto 12 50/60 12 18 1.5 2200 86 33 0.84
VENTS 125 Modern Auto 50/60 220-240 22 0.1 2400 185 35 1.00
VENTS 125 Modern Auto turbo 50/60 220-240 29 0.13 2400 232 37 1.06
VENTS 125 Modern Auto press 50/60 220-240 29 0.13 2400 188 39 1.00
VENTS 125 Modern Auto 12 50/60 12 22 1.7 2300 165 34 0.99
VENTS 150 Modern Auto 50 220-240
VENTS 150 Modern 26 0.13 2400 295 39 1.31
60 220
Auto (220 V/60 Hz)
VENTS 150 Modern Auto turbo 50 220-240
VENTS 150 Modern Auto turbo 32 0.13 2400 345 41 1.28
60 220
(220 V/60 Hz)
VENTS 150 Modern Auto press 50 220-240
VENTS 150 Modern Auto 32 0.14 2400 307 41 1.31
60 220
press (220 V/60 Hz)

VENTS 150 Modern Auto 12 50 12 29 2 2300 263 38 1.29

Mounting example Overall dimensions

Dimensions [mm]
Model
ØD B H L L1
VENTS 100 Modern Auto 99.5 196 196 117 60
VENTS 125 Modern Auto 125 220 220 124 65
VENTS 150 Modern Auto 150 242 242 139 81

L
L1
H

Certificates

The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 133


AXIAL DECORATIVE FANS

VENTS Domino Design Control


Series • Modern design and original look. Manual:
• The casing and the impeller are made of high- • The fan is controlled with a room light switch
quality durable ABS plastic, UV resistant. (not included into delivery set).
• Front panel is made of white, black or red • The fan is controlled with a built-in pull cord
organic glass in various combinations. switch "V". This option is not applicable for ceiling
mounting.
• The impeller design enhances the fan
efficiency and prolongs the motor service life. • Speed control is possible through a thyristor
speed controller (see Electrical Accessories).
• Protection rating IP34.
Several fans may connected to the same controller.
Speed controllers can not be connected to the
Motor fans with T, TH, TP, VT, VTH modification.
• Reliable motor with low energy demand. Automatic:
• Designed for continuous operation and • Speed control with a an electronic control
requires no maintenance. unit BU-1-60, refer the Electric accessories. The
control unit is available upon separate order.
• Equipped with overheating protection.
• Fan control with a turn-off delay timer "T" that
Modifications and options enables fan running from 2 to 30 minutes after
Exhaust decorative axial fan with air turning the fan off.
Domino K – the fan is equipped with a
flow up to 310 m3/h back valve to prevent air backdrafting.
• Fan control with a humidity sensor and turn-
off delay timer "TH" that enables fan switching
on and running until the indoor humidity drops
Application Domino L – the motor is equipped with below the set point adjustable from 60 to 90  %
ball bearings for long service life (appr. and subsequent fan running within the set time
• Continuous or periodic exhaust ventilation 40 thousand hours) and fan mounting at before turning off.
of bathroom, showers, kitchens and other utility any angle. The bearings are maintenance-free and
spaces. contain enough grease for the entire operating Mounting features
• Ventilation shaft mounting or duct connec- period. • The fan is mounted directly into the ventilation
tion. Domino turbo – high-powered motor. shaft.
• Low to medium air flow motion for short dis- • Flexible duct connection is recommended in
tances at low air resistance. case of the remote ventilation shaft location. The
air duct is connected to the fan exhaust flange
• Compatible with Ø 100, 125 and 150 mm air Domino 12 – equipped with a reliable
through a clamp.
ducts. low-voltage motor, 12 V.
• Fixing to wall with screws.

Domino T – equipped with a turn- • Suitable for ceiling mounting.


off delay timer adjustable from 2 to 30 • The step-down transformer (TRF 220/12-25)
minutes. enables connection of a low-voltage fan 12 V/50
Hz to 220 V/50 Hz power mains. Available upon
Domino TH – equipped
separate order.
with a turn-off delay timer
adjustable from 2 to 30
minutes and a humidity sensor adjustable from
60 to 90 %.
Domino V – equipped with a pull cord
Domino 1 switch.

Domino VT – equipped with


a pull cord switch and a turn-
off delay timer adjustable
from 2 to 30 minutes.
Domino VTH –
equipped with a pull
cord switch, turn-off
delay timer adjustable from 2 to 30 minutes and a
humidity sensor adjustable from 60 to 90 %.
Domino 2

Accessories
Air ducts Grilles and hoods Back valves Controllers Control unit Transformer Clamps

134 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Aerodynamic characteristics
Pressure, ΔP [Pa]

Pressure, ΔP [Pa]

Pressure, ΔP [Pa]
VENTS 100 Domino VENTS 125 Domino VENTS 150 Domino
VENTS 100 Domino turbo VENTS 125 Domino turbo VENTS 150 Domino turbo

VENTS 100 Domino 12 VENTS 125 Domino 12 VENTS 150 Domino 12

Air flow [m3/h] Air flow [m3/h] Air flow [m3/h]

Technical data

Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]

VENTS 100 Domino 50/60 220-240 14 0.085 2300 88 33 0.86


VENTS 100 Domino turbo 50/60 220-240 16 0.1 2300 115 36 0.94
VENTS 100 Domino 12 50/60 12 14 1.5 2200 77 32 0.88
VENTS 125 Domino 50/60 220-240 16 0.1 2400 167 34 1.11
VENTS 125 Domino turbo 50/60 220-240 24 0.105 2400 209 36 1.18
VENTS 125 Domino 12 50/60 12 16 1.7 2300 149 33 1.06
VENTS 150 Domino 50 220-240
VENTS 150 Domino 24 0.13 2400 265 37 1.35
60 220
(220 V/60 Hz)
VENTS 150 Domino turbo 50 220-240
VENTS 150 Domino turbo 30 0.13 2400 310 39 1.49
60 220
(220 V/60 Hz)

VENTS 150 Domino 12 50 12 29 2 2300 236 36 1.31

Mounting example Overall dimensions

Dimensions [mm]
Model
H B ØD L L1
VENTS 100 Domino 170 170 99.5 138 96
VENTS 125 Domino 196 196 124.5 143 101
VENTS 150 Domino 226 226 149.5 161 118

L
L1
H

Certificates

The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 135


AXIAL DECORATIVE FANS

VENTS Z Design Control


Series • Modern design and aesthetic look. Manual:
• The polished steel front panel with various • The fan is controlled by a room light switch. It
ornamental modifications. is not included in the delivery package.
• The casing and the impeller are made of high- • Speed control is possible through a thyristor
quality durable ABS plastic, UV resistant. speed controller (see Electrical Accessories).
Several fans may connected to the same controller.
• The intellectual impeller design makes the fan Speed controllers can not be connected to the
efficiency high and the service life long.
fans with T, TH, TP, VT, VTH modification.
• Protection rating IP24.
Automatic:
Motor • By the electronic control unit BU-1-60 (see
Electrical Accessories). The control unit is supplied
• Reliable and low-watt electric motor. separately.
• Designed for continuous operation and
Mounting features
requires no maintenance.
• Equipped with overheating protection. • The fan is mounted directly into the ventilation
shaft.
Modifications and Options • Flexible duct application is recommended in
Axial design fans case of remote location of the ventilation shaft.
Z L – The motor is equipped with ball The air duct is connected to the fan exhaust flange
for exhaust ventilation bearings for long service life (appr. 40 through a clamp.
with the capacity thousand hours) and fan mounting at
up to 358 m3/h any angle. The bearings are maintenance-free and • Fixed to wall by self-tapping screws.
contain enough grease for the entire operating • For 12 V low-voltage motor fan connection
period. to 220 V/50 Hz power mains use the step-down
Application transformer TRF 220/12-25 that is available upon
Z turbo – high-powered motor.
separate order.
• Continuous or periodic exhaust ventilation
of bathroom, showers, kitchens and other utility
spaces. Z 12 – modification with low-voltage
• Ventilation shaft mounting or duct connec- motor. 12 V AC power supply.
tion.
• Low to medium air flow motion for short dis-
tances at low air resistance.
• Compatible with Ø 100, 125 and 150 mm air
ducts.

Front panel modifications

Z1 Z2 Z3 Z4 Z5 Z6

Accessories
Backdraft
Air ducts Grilles and hoods damper Speed controllers Clamps

136 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Aerodynamic characteristics

Air flow [m3/h] Air flow [m3/h] Air flow [m3/h]

Technical data

Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]

VENTS 100 Z 50/60 220-240 14 0.085 2300 105 37 0.41


VENTS 100 Z turbo 50/60 220-240 16 0.1 2300 135 38 0.41
VENTS 100 Z 12 50/60 12 14 1.5 2200 92 36 0.40
VENTS 125 Z 50/60 220-240 16 0.1 2400 185 38 0.48
VENTS 125 Z turbo 50/60 220-240 24 0.105 2400 243 39 0.48
VENTS 125 Z 12 50/60 12 16 1.33 2300 165 37 0.46
VENTS 150 Z 50/60 220-240
VENTS 150 Z 24 0.13 2400 298 40 0.80
60 220
(220 V/60 Hz)
VENTS 150 Z turbo 50/60 220-240
VENTS 150 Z turbo 29 0.13 2400 358 44 0.80
60 220
(220 V/60 Hz)
VENTS 150 Z 12 50 12 29 2 2300 266 39 0,76

Mounting example Overall dimensions

Dimensions [mm]
Model
ØD B H L L1
VENTS 100 Z 100 181 120 143 56
VENTS 125 Z 125 208 140 143 56
VENTS 150 Z 150 231 165 166 56

Certificates

The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 137


AXIAL DECORATIVE FANS

VENTS Z star Design Control


Series • The polished steel front panel with various Manual:
ornamental modifications. • The fan is controlled by a room light switch. It
is not included in the delivery package.
• A 2 W LED lamp is integrated into the fan
casing. • Speed control is possible through a thyristor
speed controller (see Electrical Accessories).
• Modern design and aesthetic look.
Several fans may connected to the same controller.
• The casing and the impeller are made of high- Speed controllers can not be connected to the
quality durable ABS plastic, UV resistant. fans with T, TH, TP, VT, VTH modification.
• The intellectual impeller design makes the fan Automatic:
efficiency high and the service life long.
• Protection rating IP24.
• By the electronic control unit BU-1-60 (see
Electrical Accessories). The control unit is supplied
separately.
Motor
• By the timer T (the built-in turn-off delay timer
enables the fan operation within 2 to 30 minutes
• Reliable and low-watt electric motor.
after the fan switching off ).
• Designed for continuous operation and
requires no maintenance. • By the humidity sensor and timer TH (if the
humidity level in the room exceeds the sensor
• Equipped with overheating protection.
threshold adjustable value within 60-90 % the fan
Axial design fans switches automatically on and operates until the
for exhaust ventilation Modifications and Options humidity level drops to the standard level, after
with the capacity Z star K – fan is equipped with a
that the fan continues operating within the time
up to 302 m3/h period according to the timer setting, then shuts
backdraft damper for back flow
down).
preventing.
Z star L – the motor is equipped with Mounting features
Application
ball bearings for long service life (appr.
• Continuous or periodic exhaust ventilation 40 thousand hours) and fan mounting at • The fan is mounted directly into the ventilation
shaft.
of bathroom, showers, kitchens and other utility any angle. The bearings are maintenance-free and
spaces. contain enough grease for the entire operating • Flexible duct application is recommended in
period. case of remote location of the ventilation shaft.
• Ventilation shaft mounting or duct connec- The air duct is connected to the fan exhaust flange
tion. Z star turbo – high-powered motor.
through a clamp.
• Low to medium air flow motion for short dis-
• Fixed to wall by self-tapping screws.
tances at low air resistance.
• Compatible with Ø 100, 125 and 150 mm air Z star 12 – modification with low- • Both parallel or separate switching of the fan
voltage motor. 12 V AC power supply. and the built-in lamp (refer wiring diagrams).
ducts.
• For 12 V low-voltage motor fan connection
to 220 V/50 Hz power mains use the step-down
Z star T* – equipped with a regulated transformer TRF 220/12-25 that is available upon
timer with the operating time from 2 to separate order.
30 minutes.
Z star TH* – equipped with a
timer with the operating time
from 2 to 30 minutes and a
humidity sensor with the threshold value from 60
to 90 %.

LED lamp, 2 W * only for Ø 100 mm fans

Front panel modifications

Z star 1 Z star 2 Z star 3 Z star 4 Z star 5 Z star 6

Accessories
Backdraft
Air ducts Grilles and hoods damper Speed controllers Clamps

138 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Aerodynamic characteristics

Air flow [m3/h] Air flow [m3/h] Air flow [m3/h]

Technical data

Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]

VENTS 100 Z star 50/60 220-240 14 0.085 2300 89 33 0.61


VENTS 100 Z star turbo 50/60 220-240 16 0.1 2300 116 36 0.69
VENTS 100 Z star 12 50/60 12 14 1.5 2200 78 32 0.60
VENTS 125 Z star 50/60 220-240 16 0.1 2400 164 34 0.75
VENTS 125 Z star turbo 50/60 220-240 24 0.105 2400 206 36 0.83
VENTS 125 Z star 12 50/60 12 16 1.7 2300 146 33 0.73
VENTS 150 Z star 50 220-240
VENTS 150 Z star 24 0.13 2400 258 37 0.94
60 220
(220 V/60 Hz)
VENTS 150 Z star turbo 50 220-240
VENTS 150 Z star turbo 29 0.13 2400 302 39 1.08
60 220
(220 V/60 Hz)

VENTS 150 Z star 12 50 12 29 2 2300 230 36 0.90

Mounting example Overall dimensions

Dimensions [mm]
Model
ØD B H L L1
VENTS 100 Z star 100 181 120 148 56
VENTS 125 Z star 125 204 140 154 56
VENTS 150 Z star 150 231 165 171 56
VENTS 100 Z star T 98 183 122 151 65
VENTS 100 Z star TH 98 183 122 151 65

Certificates

The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 139


AXIAL DECORATIVE FANS

VENTS Vitro Design Control


Series • The glass front panel with various ornamental Manual:
modifications. • The fan is controlled by a room light switch. It
is not included in the delivery package.
• Modern design and aesthetic look.
• The casing and the impeller are made of high- • Speed control is possible through a thyristor
quality durable ABS plastic, UV resistant. speed controller (see Electrical Accessories).
Several fans may connected to the same controller.
• The intellectual impeller design makes the fan Speed controllers can not be connected to the
efficiency high and the service life long. fans with T, TH, TP, VT, VTH modification.
• Protection rating IP24. Automatic:

Motor
• By the electronic control unit BU-1-60 (see
Electrical Accessories). The control unit is supplied
separately.
• Reliable and low-watt electric motor.
• Designed for continuous operation and
Mounting features
requires no maintenance.
• Equipped with overheating protection. • The fan is mounted directly into the ventilation
shaft.

Modifications and Options • Flexible duct application is recommended in


case of remote location of the ventilation shaft.
Vitro L – the motor is equipped with The air duct is connected to the fan exhaust flange
Axial design fans ball bearings for long service life (appr. through a clamp.
for exhaust ventilation 40 thousand hours) and fan mounting at • Fixed to wall by self-tapping screws.
with the capacity any angle. The bearings are maintenance-free and
up to 358 m3/h contain enough grease for the entire operating • For 12 V low-voltage motor fan connection
to 220 V/50 Hz power mains use the step-down
period.
transformer TRF 220/12-25 that is available upon
Vitro turbo – high-powered motor. separate order.
Application
• Continuous or periodic exhaust ventilation
of bathroom, showers, kitchens and other utility Vitro 12 – modification with low-
spaces. voltage motor. 12 V AC power supply.
• Ventilation shaft mounting or duct connec-
tion.
• Low to medium air flow motion for short dis-
tances at low air resistance.
• Compatible with Ø 100, 125 and 150 mm air
ducts.

Front panel modifications

Vitro 1 Vitro 2 Vitro 3 Vitro 4 Vitro 5 Vitro 6

Accessories
Backdraft
Air ducts Grilles and hoods damper Speed controllers Clamps

140 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Aerodynamic characteristics

Air flow [m3/h] Air flow [m3/h] Air flow [m3/h]

Technical data

Power Sound Pressure


Frequency Current Maximum air Weight
Model Voltage [V] Consumption R.p.m. Level at 3 m
[Hz] [A] flow [m3/h] [kg]
[W] [dBA]

VENTS 100 Vitro 50/60 220-240 14 0.085 2300 105 37 0.41


VENTS 100 Vitro turbo 50/60 220-240 16 0.1 2300 135 38 0.41
VENTS 100 Vitro 12 50/60 12 14 1.5 2200 92 36 0.40
VENTS 125 Vitro 50/60 220-240 16 0.1 2400 185 38 0.48
VENTS 125 Vitro turbo 50/60 220-240 24 0.105 2400 243 39 0.48
VENTS 125 Vitro 12 50/60 12 16 1.33 2300 165 37 0.46
VENTS 150 Vitro 50 220-240
VENTS 150 Vitro 24 0.13 2400 298 40 0.80
60 220
(220 V/60 Hz)
VENTS 150 Vitro turbo 50 220-240
VENTS 150 Vitro turbo 29 0.13 2400 358 44 0.80
60 220
(220 V/60 Hz)

VENTS 150 Vitro 12 50 12 29 2 2300 266 39 0.76

Mounting example Overall dimensions

Dimensions [mm]
Model
ØD B H L L1
VENTS 100 Vitro 100 183 120 145 58
VENTS 125 Vitro 125 205 140 146 58
VENTS 150 Vitro 150 233 165 169 58

Certificates

The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 141


AXIAL DECORATIVE FANS

VENTS Vitro star Design Control


Series • The glass front panel with various ornamental Manual:
modifications. • The fan is controlled by a room light switch. It
is not included in the delivery package.
• Modern design and aesthetic look.
• The casing and the impeller are made of high- • Speed control is possible through a thyristor
quality durable ABS plastic, UV resistant. speed controller (see Electrical Accessories).
Several fans may connected to the same controller.
• The intellectual impeller design makes the fan Speed controllers can not be connected to the
efficiency high and the service life long. fans with T, TH, TP, VT, VTH modification.
• A 2 W LED lamp is integrated into the fan Automatic:
casing.
• Protection rating IP24.
• By the electronic control unit BU-1-60 (see
Electrical Accessories). The control unit is supplied
separately.
Motor
• By the timer T (the built-in turn-off delay timer
enables the fan operation within 2 to 30 minutes
• Reliable and low-watt electric motor.
after the fan switching off ).
• Designed for continuous operation and
requires no maintenance. • By the humidity sensor and timer TH (if the
humidity level in the room exceeds the sensor
• Equipped with overheating protection.
threshold adjustable value within 60-90 % the fan
Axial design fans switches automatically on and operates until the
for exhaust ventilation Modifications and Options humidity level drops to the standard level, after
with the capacity Vitro star K – fan is equipped with
that the fan continues operating within the time
up to 302 m3/h period according to the timer setting, then shuts
a backdraft damper for back flow
down).
preventing.
Vitro star L – the motor is equipped Mounting features
Application
with ball bearings for long service
• Continuous or periodic exhaust ventilation life (appr. 40 thousand hours) and • The fan is mounted directly into the ventilation
shaft.
of bathroom, showers, kitchens and other utility fan mounting at any angle. The bearings are
spaces. maintenance-free and contain enough grease for • Flexible duct application is recommended in
the entire operating period. case of remote location of the ventilation shaft.
• Ventilation shaft mounting or duct connec- The air duct is connected to the fan exhaust flange
tion. Vitro star turbo – high-powered
through a clamp.
motor.
• Low to medium air flow motion for short dis-
• Fixed to wall by self-tapping screws.
tances at low air resistance.
• Compatible with Ø 100, 125 and 150 mm air Vitro star 12 – modification with low- • Both parallel or separate switching of the fan
voltage motor. 12 V AC power supply. and the built-in lamp (refer wiring diagrams).
ducts.
• For 12 V low-voltage motor fan connection
to 220 V/50 Hz power mains use the step-down
Vitro star T* – equipped with a
transformer TRF 220/12-25 that is available upon
regulated timer with the operating time
separate order.
from 2 to 30 minutes.
Vitro star TH* – equipped
with a timer with the
operating time from 2 to 30
minutes and a humidity sensor with the threshold
value from 60 to 90 %.

LED lamp, 2 W * only for 100 mm fans

Front panel modifications

Vitro star 1 Vitro star 2 Vitro star 3 Vitro star 4 Vitro star 5 Vitro star 6

Accessories
Backdraft
Air ducts Grilles and hoods damper Speed controllers Clamps

142 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Aerodynamic characteristics

Air flow [m3/h] Air flow [m3/h] Air flow [m3/h]

Technical data

Power Sound Pressure


Frequency Current Maximum air Weight
Model Voltage [V] Consumption R.p.m. Level at 3 m
[Hz] [A] flow [m3/h] [kg]
[W] [dBA]

VENTS 100 Vitro star 50/60 220-240 14 0.085 2300 89 33 0.61


VENTS 100 Vitro star turbo 50/60 220-240 16 0.1 2300 116 36 0.69
VENTS 100 Vitro star 12 50/60 12 14 1.5 2200 78 32 0.60
VENTS 125 Vitro star 50/60 220-240 16 0.1 2400 164 34 0.75
VENTS 125 Vitro star turbo 50/60 220-240 24 0.105 2400 206 36 0.83
VENTS 125 Vitro star 12 50/60 12 16 1.7 2300 146 33 0.73
VENTS 150 Vitro star 50 220-240
VENTS 150 Vitro star 24 0.13 2400 258 37 0.94
60 220
(220 V/60 Hz)
VENTS 150 Vitro star turbo 50 220-240
VENTS 150 Vitro star turbo 29 0.13 2400 302 39 1.08
60 220
(220 V/60 Hz)

VENTS 150 Vitro star 12 50 12 29 2 2300 230 36 0.90

Mounting example Overall dimensions

Dimensions [mm]
Model
ØD B H L L1
VENTS 100 Vitro star 100 183 120 151 58
VENTS 100 Vitro star T 98 183 122 151 65
VENTS 100 Vitro star TH 98 183 122 151 65
VENTS 125 Vitro star 125 205 140 156 58
VENTS 150 Vitro star 150 233 165 173 58

Certificates

The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 143


AXIAL DECORATIVE FANS

VENTS X Design XVTH – equipped


with a pull cord
Series • Modern design and aesthetic look. switch, regulated
• The casing and the impeller are made of high- timer with the operating time adjustable from
quality durable ABS plastic, UV resistant. 2 to 30 minutes and a humidity sensor with the
operating threshold range from 60 to 90 %.
• The intellectual impeller design makes the fan
efficiency high and the service life long.
Control
• Decorative replaceable colour covers: light
Manual:
blue, bright green, yellow and pink.
• Protection rating IP24. • The fan is controlled by a room light switch. It
is not included in the delivery package.

Motor • The fan is controlled by the built-in pull cord


switch V. Not applied in case of ceiling mounting.
• Reliable and low-watt electric motor. • Speed control is possible through a thyristor
• Designed for continuous operation and speed controller (see Electrical Accessories).
requires no maintenance. Several fans may connected to the same controller.
Speed controllers can not be connected to the
• Equipped with overheating protection.
fans with T, TH, TP, VT, VTH modification.
Automatic:
Modifications and Options
Axial decorative fans
X alumat – fan with a matt gray painted front
• By the electronic control unit BU-1-60 (see
Electrical Accessories). The control unit is supplied
for exhaust ventilation plate. separately.
with the capacity X K – fan is equipped with a backdraft
up to 302 m3/h damper for back flow preventing.
• By the timer T (the built-in turn-off delay timer
enables the fan operation within 2 to 30 minutes
after the fan switching off ).
Application X L – the motor is equipped with ball • By the humidity sensor and timer TH (if the
bearings for long service life (appr. 40 humidity level in the room exceeds the sensor
• Continuous or periodic exhaust ventilation thousand hours) and fan mounting at threshold adjustable value within 60-90 % the fan
of bathroom, showers, kitchens and other utility any angle. The bearings are maintenance-free and switches automatically on and operates until the
spaces. contain enough grease for the entire operating humidity level drops to the standard level, after
• Ventilation shaft mounting or duct connec- period. that the fan continues operating within the time
tion. X turbo – high-powered motor. period according to the timer setting, then shuts
down).
• Low to medium air flow motion for short dis-
tances at low air resistance.
Mounting features
• Compatible with Ø 100, 125 and 150 mm air X 12 – modification with low-voltage
• The fan is mounted directly into the ventilation
ducts. motor. 12 V AC power supply. shaft.
• Flexible duct application is recommended in
X T – equipped with a regulated timer case of remote location of the ventilation shaft.
with the operating time from 2 to 30 The air duct is connected to the fan exhaust flange
minutes. through a clamp.
XTH – equipped with a timer • Fixed to wall by self-tapping screws.
with the operating time from 2
to 30 minutes and a humidity
• Suitable for ceiling mounting.

sensor with the threshold value from 60 to 90 %. • For 12 V low-voltage motor fan connection
to 220 V/50 Hz power mains use the step-down
XV – equipped with a pull cord switch. transformer TRF 220/12-25 that is available upon
separate order.

XVT – equipped with a pull


cord switch and a regulated
timer with the operating time
adjustable from 2 to 30 minutes.

Accessories
Backdraft
Air ducts Grilles and hoods damper Speed controllers Clamps

144 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Aerodynamic characteristics

Air flow [m3/h] Air flow [m3/h] Air flow [m3/h]

Technical data

Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]

VENTS 100 X 50/60 220-240 14 0.085 2300 89 33 0.61


VENTS 100 X turbo 50/60 220-240 16 0.1 2300 116 36 0.69
VENTS 100 X 12 50/60 12 14 1.5 2200 78 32 0.60
VENTS 125 X 50/60 220-240 16 0.1 2400 164 34 0.75
VENTS 125 X turbo 50/60 220-240 24 0.105 2400 206 36 0.83
VENTS 125 X 12 50/60 12 16 1.7 2300 146 33 0.73
VENTS 150 X 50 220-240
VENTS 150 X 24 0.13 2400 258 37 0.94
60 220
(220 V/60 Hz)
VENTS 150 X turbo
50 220-240
(220 V/60 Hz)
29 0.13 2400 302 39 1.08
VENTS 150 X turbo
60 220
(220 V/60 Hz)

VENTS 150 X 12 50 12 29 2 2300 230 36 0.90

Mounting example Overall dimensions

Dimensions [mm]
Model
ØD B H L L1
VENTS 100 X 100 152 120 125 30
VENTS 125 X 125 177 140 143 42
VENTS 150 X 150 205 165 160 42

Certificates

The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 145


AXIAL DECORATIVE FANS

VENTS X star Design Control


Series • Modern design and aesthetic look. Manual:

• The casing and the impeller are made of high- • The fan is controlled by a room light switch. It
quality durable ABS plastic, UV resistant. is not included in the delivery package.

• The intellectual impeller design makes the fan • Speed control is possible through a thyristor
efficiency high and the service life long. speed controller (see Electrical Accessories).
Several fans may connected to the same controller.
• A 2 W LED lamp is integrated into the fan Speed controllers can not be connected to the
casing. fans with T, TH, TP, VT, VTH modification.
• Protection rating IP24. Automatic:

Motor
• By the electronic control unit BU-1-60 (see
Electrical Accessories). The control unit is supplied
separately.
• Reliable and low-watt electric motor.
• Designed for continuous operation and
Mounting features
requires no maintenance.
• Equipped with overheating protection. • The fan is mounted directly into the ventilation
shaft.

Modifications and Options • Flexible duct application is recommended in


case of remote location of the ventilation shaft.
Axial decorative fans The air duct is connected to the fan exhaust flange
X star alumat – fan with a matt gray painted
for exhaust ventilation front plate. through a clamp.
with the capacity X star K – fan is equipped with a • Fixed to wall by self-tapping screws.
up to 302 m3/h backdraft damper for back flow • Suitable for ceiling mounting.
preventing.
• Both parallel or separate switching of the fan
X star L – the motor is equipped with and the built-in lamp (refer wiring diagrams).
Application
ball bearings for long service life (appr.
• For 12 V low-voltage motor fan connection
• Continuous or periodic exhaust ventilation 40 thousand hours) and fan mounting at
to 220 V/50 Hz power mains use the step-down
of bathroom, showers, kitchens and other utility any angle. The bearings are maintenance-free and
transformer TRF 220/12-25 that is available upon
spaces. contain enough grease for the entire operating
separate order.
period.
• Ventilation shaft mounting or duct connec-
tion. X star turbo – high-powered motor.
• Low to medium air flow motion for short dis-
tances at low air resistance.
• Compatible with Ø 100, 125 and 150 mm air X star 12 – modification with low-
ducts. voltage motor. 12 V AC power supply.

Vents X star alumat LED lamp, 2 W

Accessories
Backdraft
Air ducts Grilles and hoods damper Speed controllers Clamps

146 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Aerodynamic characteristics

Air flow [m3/h] Air flow [m3/h] Air flow [m3/h]

Technical data

Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]

VENTS 100 X star 50/60 220-240 16 0.085 2300 89 33 0.61


VENTS 100 X star turbo 50/60 220-240 16 0.1 2300 116 36 0.69
VENTS 100 X star 12 50/60 12 14 1.5 2200 78 32 0.60
VENTS 125 X star 50/60 220-240 16 0.1 2400 164 34 0.75
VENTS 125 X star turbo 50/60 220-240 24 0.105 2400 206 36 0.83
VENTS 125 X star 12 50/60 12 16 1.7 2300 146 33 0.73
VENTS 150 X star 50 220-240
VENTS 150 X star 24 0.13 2400 258 37 0.94
60 220
(220 V/60 Hz)
VENTS 150 X star turbo 50 220-240
VENTS 150 X star turbo 29 0.13 2400 302 39 1.08
60 220
(220 V/60 Hz)

VENTS 150 X star 12 50 12 29 2 2300 230 36 0.90

Mounting example Overall dimensions

Dimensions [mm]
Model
ØD B H L L1
VENTS 100 X star 100 152 120 131 36
VENTS 125 X star 125 177 140 143 42
VENTS 150 X star 150 205 165 160 42

Certificates

The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 147


AXIAL DECORATIVE FANS

VENTS Lumis Design Control


Series • Modern design and aesthetic look. Manual:
• The casing and the impeller are made of high- • The fan is controlled with a room light switch
quality durable ABS plastic, UV resistant. (not included in the delivery).
• The impeller design enhances the fan • Speed control with a thyristor speed controller,
efficiency and prolongs the motor service life. refer to the Electric accessories. Several fans may
be connected to one controller.
• The 10 watt LED backlight lamp is integrated
in the casing with a working life of 40 000 hours. Automatic:
• The lamp colour temperature is 3000 K (warm • Speed control with a an electronic control
light). unit BU-1-60, refer to the Electric accessories. The
control unit is available upon separate order.
• Protection rating IP24.

Motor Mounting features

• Reliable motor with low energy demand. • The fan is mounted directly into the ventilation
shaft.
• Designed for continuous operation and
requires no maintenance. • Flexible duct connection is recommended in
case of the remote ventilation shaft location. The
• Equipped with overheating protection. air duct is connected to the fan exhaust flange
through a clamp.
Exhaust axial fan Modifications and options
• Fixing to wall with screws.
with integrated light source. Lumis 100 K – the fan is equipped with a • Suitable for ceiling mounting.
Air flow back valve to prevent air back drafting.
up to 115 m3/h
Lumis 100 L – the motor is equipped
Application with ball bearings for long service
life (appr. 40 thousand hours) and
• Continuous or periodic exhaust ventilation fan mounting at any angle. The bearings are
of bathroom, showers, kitchens and other utility maintenance-free and contain enough grease for
spaces. the entire operating period.
• Ventilation shaft mounting or duct connec- Lumis 100 turbo – high-powered
tion. motor.
• Low to medium air flow motion for short dis-
tances at low air resistance.
• Compatible with Ø 100 mm air ducts.

Accessories
Speed
Air ducts Grilles and hoods Back valves controllers Control unit Clamps

148 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Aerodynamic characteristics

VENTS Lumis 100


VENTS Lumis 100 turbo

Air flow [m3/h]

Technical data

Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]

VENTS Lumis 100 50/60 220-240 24 0.135 2410 92 33 0.79


VENTS Lumis 100 turbo 50/60 220-240 26 0.15 2400 115 37 0.87

Mounting example Overall dimensions

Dimensions [mm]
Model
Ø D1 ØD L L1
VENTS Lumis 100 178 99.4 133.5 46
VENTS Lumis 100 turbo 178 99.4 133.5 46

L
L1
D

D1

Certificates

The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 149


AXIAL WINDOW FANS

 VENTS MAO1 and VENTS MAO1 reverse Series

Axial window fan with automatic louver shutters for exhaust ventilation with the capacity up to
345 m3/h.

Axial window reverse fan with automatic louver shutters for exhaust ventilation with the capacity
up to 202 m3/h.

 VENTS MAO2 Series

Axial window fan with automatic louver shutters for exhaust ventilation with the capacity up to
232 m3/h. The fan is equipped with an external hood.

 VENTS M1OK2 Series

Axial window fan with a backdraft damper for exhaust ventilation with the capacity up to 232
m3/h. The fan is equipped with an external hood.

 VENTS VV Series

Axial window fan with automatic louver shutters for exhaust ventilation with the capacity up to
455 m3/h. Flange mounting sizes 180 mm and 230 mm.

 VENTS VVR Series

Axial window fan with automatic louver shutters and reversing motor for exhaust or supply
ventilation with the capacity up to 455 m3/h. Flange mounting sizes 180 mm and 230 mm.

150 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Axial window fans
VENTS MAO1 Series page
Air flow up to 345 m /h
3 152

Axial window fans


VENTS MAO2 Series page
Air flow up to 232 m /h
3 152

Axial window reverse fans


VENTS MAO1 reverse page
Air flow up to 202 m /h
3 154

Axial window fans


VENTS M1OK2 Series page
Air flow up to 232 m /h
3 156

Axial window fans


VENTS VV Series page
Air flow up to 455 m /h
3 158

Axial window fans


VENTS VVR Series page
Air flow up to 455 m /h
3 158

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 151


AXIAL WINDOW FANS

VENTS MAO1 Application MAO1 12 / MAO2 12 – modification


with low-voltage motor. 12 V AC power
Series • Continuous or periodic exhaust ventilation supply.
of bathroom, showers, kitchens and other utility
MAO1 T / MAO2 T – equipped with a
spaces.
regulated timer with the operating time
• For mounting in windows. from 2 to 30 minutes.
MAO1 V / MAO2 V – equipped with a
Design pull cord switch.

• Modern design and aesthetic look.


MAO1 VT / MAO2 VT –
• The casing and the impeller are made of high-
equipped with a pull cord
quality durable ABS plastic, UV resistant.
switch and a regulated timer
• The intellectual impeller design makes the fan with the operating time adjustable from 2 to 30
efficiency high and the service life long. minutes.
• The fan and motor are specially designed for
Axial window fans silent operation. Control
for exhaust ventilation • Fan is equipped with a thermal actuator Manual:
that provides smooth opening and shutting
with the capacity up to 345 m3/h
of automatic louver shutters for air back flow
• The fan is controlled by a room light switch. It
is not included in the delivery package.
preventing.
• The fan is controlled by the built-in pull cord
• MAO2 Series fans are equipped with an switch V.
external hood.
Automatic:
VENTS MAO2 • Protection rating IP24.
• By the electronic control unit BU-1-60 (see
Series Motor
Electrical Accessories). The control unit is supplied
separately.
• Reliable and low-watt electric motor. • By the timer T (the built-in turn-off delay timer
enables the fan operation within 2 to 30 minutes
• Designed for continuous operation and
after the fan switching off ).
requires no maintenance.
• Equipped with overheating protection. Mounting features

Modifications and Options


• The fan is mounted directly into the window
opening.
MAO1 L / MAO2 L – the motor is • For 12 V low-voltage motor fan connection
equipped with ball bearings for long to 220 V/50 Hz power mains use the step-down
service life (appr. 40 thousand hours) transformer TRF 220/12-25 that is available upon
and fan mounting at any angle. The bearings are separate order.
Axial window fans maintenance-free and contain enough grease for
the entire operating period.
for exhaust ventilation
with the capacity up to 232 m3/h MAO1 turbo / MAO2 turbo – high-
powered motor.

Back side of MAO2 fan Fan OFF – louver shutters CLOSED Fan ON – louver shutters OPEN

Accessories
Speed controllers

152 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Aerodynamic characteristics

Air flow [m3/h] Air flow [m3/h]

Technical data
Power
Frequency Voltage Maximum air Sound Pressure SEC Weight
Model Consumption Tok, A R.p.m.
[Hz] [V] flow [m3/h] Level at 3 m [dBA] class [kg]
[W]
VENTS 125 MAO1 50/60 220-240 22 0.1 2400 185 35 E 1.15
VENTS 125 MAO1 turbo 50/60 220-240 24 0.105 2400 232 37 E 1.31
VENTS 125 MAO1 12 50/60 12 16 1.7 2300 165 34 E 1.13
VENTS 125 MAO2 50/60 220-240 22 0.1 2400 185 35 E 1.14
VENTS 125 MAO2 turbo 50/60 220-240 24 0.105 2400 232 37 E 1.24
VENTS 125 MAO2 12 50/60 12 16 1.7 2300 165 34 E 1.12
VENTS 150 MAO1 50 220-240
VENTS 150 MAO1 26 0.13 2400 295 41 E 1.53
60 220
(220 V/60 Hz)
VENTS 150 MAO1 turbo 50 220-240
VENTS 150 MAO1 turbo 29 0.13 2400 345 43 E 1.67
60 220
(220 V/60 Hz)

VENTS 150 MAO1 12 50 12 29 2 2300 263 40 E 1.49

Overall dimensions
Dimensions [mm]
Model
ØD B H H1 L1 L2

VENTS 125 MAO1 125 190 173 – 58 53


VENTS 150 MAO1 150 212 195 – 66 60
VENTS 125 MAO2 – 190 173 160 58 123

Mounting examples
MAO1 MAO2

Certificates

The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 153


AXIAL WINDOW REVERSE FANS

VENTS MAO1 reverse Series Application Motor


• Permanent or periodic exhaust and supply • Reliable DC motor (12V) with low energy
ventilation of kitchens, garages, workshops and demand.
residential premises.
• Two-speed reverse DC motor provides fan
• For mounting in windows. operation both in supply and exhaust mode.
• Special motor design ensures low noise level.
Design • Designed for continuous operation and
required no maintenance.
• Modern design and aesthetic look.
• The casing and the impeller are made of high- • Equipped with overload protection.
quality durable ABS plastic, UV resistant.
Control
• The intellectual impeller design makes the fan
Manual control:
efficiency high and the service life long.
• The fan and motor are specially designed for • Three button control unit (included into
silent operation. delivery set) with integrated circuit board is used
Axial window two-speed reverse fans for:
for exhaust and supply ventilation • Fan is equipped with a thermal actuator 1. On/off switching;
that provides smooth opening and shutting
with the capacity
of automatic louver shutters for air back flow 2. Fan speed switching on/off (min – max);
up to 202 m3/h preventing. 3. Fan operation mode switching (exhaust mode –
• Supplied with a three bottom control unit and supply mode).
220 V – 12 V transformer.
• Transformer provides reliable fan operation Mounting features
with safe power supply 12 V. • Fan is installed directly into window opening.
• Protection rating IP24.

Exhaust mode 2 speed on

Fan off – louver


shutters CLOSED Control unit Supply mode 1 speed off

Fan on – louver
shutters OPEN

154 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Aerodynamic characteristics

Air flow [m3/h]

Technical Data

Power Sound
Frequency Voltage Current Maximum air SEC Weight
Model Mode Speed Consumption R.p.m. Pressure Level
[Hz] [V] [A] flow [m3/h] class [kg]
[W] at 3 m [dBA]

max 50/60 8.7 0.045 1950 202 33


exhaust
VENTS 150 min 50/60 5.2 0.025 1215 123 28
220-240 E 1.53
MAO1 reverse max 50/60 7.6 0.045 2030 187 32
supply
min 50/60 5.1 0.025 1210 110 26

Overall dimensions

Dimensions [mm]
Model
ØD B H H1 L1 L2

VENTS 150 MAO1 reverse 150 212 195 – 66 60

Mounting examples

Fan operation in EXHAUST mode Fan operation in reverse SUPPLY-


EXHAUST mode

Certificates

The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 155


AXIAL WINDOW FANS

VENTS M1OK2 Design Control


Manual:
Series • Modern design and aesthetic look.
• The casing and the impeller are made of high- • The fan is controlled by a room light switch. It
quality durable ABS plastic, UV resistant. is not included in the delivery package.

• The intellectual impeller design makes the fan • The fan is controlled by the built-in pull cord
efficiency high and the service life long. switch V.

• The fan and motor are specially designed for • Speed control is possible through a thyristor
silent operation. speed controller (see Electrical Accessories).
Several fans may connected to the same controller.
• Fan is equipped with a backdraft damper for Speed controllers can not be connected to the
back flow preventing. fans with T, TH, TP, VT, VTH modification.
• The fan is equipped with an external hood. Automatic:
• Protection rating IP24.
• By the electronic control unit BU-1-60 (see
Electrical Accessories). The control unit is supplied
Motor separately.
Axial window fans • Reliable and low-watt electric motor. • By the timer T (the built-in turn-off delay timer
for exhaust ventilation enables the fan operation within 2 to 30 minutes
• Designed for continuous operation and
after the fan switching off ).
with the capacity up to 232 m3/h requires no maintenance.
• Equipped with overheating protection. Mounting features
Application • The fan is mounted directly into the window
Modifications and Options opening.
• Continuous or periodic exhaust ventilation M1OK2 L – the motor is equipped with • For 12 V low-voltage motor fan connection
of bathroom, showers, kitchens and other utility to 220 V/50 Hz power mains use the step-down
ball bearings for long service life (appr.
spaces. transformer TRF 220/12-25 that is available upon
40 thousand hours) and fan mounting
• For mounting in windows. at any angle. The bearings are maintenance- separate order.
free and contain enough grease for the entire
operating period.
M1OK2 turbo – high-powered motor.

M1OK2 12 – modification with low-


voltage motor. 12 V AC power supply.

M1OK2 T – equipped with a regulated


timer with the operating time from
2 to 30 minutes.
M1OK2 V – equipped with a pull cord
switch.
Back side of M1OK2 fan

M1OK2 VT – equipped
with a pull cord switch and
a regulated timer with the
operating time adjustable from 2 to 30 minutes.

Accessories
Speed controllers

156 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Aerodynamic characteristics

Air flow [m3/h]

Technical data

Power Sound Pressure


Frequency Voltage [V] Current Maximum air SEC Weight
Model Consumption R.p.m. Level at 3 m
[Hz] /50 Hz [A] flow [m3/h] class [kg]
[W] [dBA]

VENTS 125 M1OK2 50/60 220-240 22 0.1 2400 185 35 E 1.15


VENTS 125 M1OK2 turbo 50/60 220-240 24 0.105 2400 232 37 E 1.31
VENTS 125 M1OK2 12 50/60 12 16 1.7 2300 165 34 E 1.13

Mounting example Overall dimensions

Dimensions [mm]
Model
ØD B H H1 L1 L2

VENTS 125 M1OK2 – 190 173 160 58 123

Certificates

The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 157


AXIAL WINDOW FANS

VENTS VV Application Control


Series • Continuous or periodic exhaust ventilation Manual:
of bathroom, showers, kitchens and other utility • The fan is controlled by a room light switch. It
spaces. is not included in the delivery package.
• For mounting in windows. • Speed control is possible through a thyristor
speed controller (see Electrical Accessories).
Design Several fans may connected to the same
controller. Speed controllers can not be
• Modern design and aesthetic look. connected to the fans with T, TH, TP, VT, VTH
modification.
• The casing and the impeller are made of high-
quality durable ABS plastic, UV resistant. Automatic:
• The intellectual impeller design makes the • By the electronic control unit BU-1-60
fan efficiency high and the service life long. (see Electrical Accessories). The control unit is
supplied separately.
• The fan and motor are specially designed for
Axial window fan with automatic silent operation.
Mounting features
louver shutters for exhaust • Equipped with automatic louver shutter for
ventilation with the air back flow prevention. • The fan is mounted directly into the window
opening.
capacity up to 455 m3/h • Protection rating IP24.

Motor

VENTS VVR • Reliable and low-watt electric motor.


• Designed for continuous operation and
Series requires no maintenance.
• Equipped with overheating protection.
• VVR series fans are equipped with a reversing
motor for combination of air exhaust and air
supply functions.

Axial window fan with automatic


louver shutters and reversing
motor for exhaust and supply Fan ON – louver shutters OPEN Fan OFF – louver shutters CLOSED
ventilation with the
capacity up to 455 m3/h

Accessories
Speed controllers

158 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Aerodynamic characteristics

Air flow [m3/h] Air flow [m3/h]

Technical data

Power Sound Pressure


Frequency Current Maximum air Weight
Model Voltage [V] Consumption R.p.m. Level at 3 m
[Hz] [A] flow [m3/h] [kg]
[W] [dBA]
VENTS VV 180 air exhaust 50/60 220-240 25 0.10 1400 212 31 1.6
air exhaust 212 31
VENTS VVR 180 50/60 220-240 25 0.10 1400 1.6
air supply 176 31
VENTS VV 230 air exhaust 50/60 220-240 29 0.13 1300 455 32 2.2
air exhaust 455 32
VENTS VVR 230 50/60 220-240 29 0.13 1300 2.2
air supply 290 32

Mounting example Overall dimensions

Dimensions [mm]
Model
A B C D
VENTS VV 180 230 65 87 177
VENTS VVR 180 230 65 87 177
VENTS VV 230 295 74 85 237
VENTS VV 230 295 74 85 237

Certificates

The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 159


CENTRIFUGAL FANS

 VENTS CF Series

Centrifugal single-speed fans with a built-in filter for exhaust ventilation with the air flow of up to
122 m3/h. Compatible with Ø 100 mm air ducts.

 VENTS CF3 Series

Centrifugal three-speed fans with a built-in filter for exhaust ventilation with the air flow of up to 90
m3/h. Equipped with a three speed switch. Compatible with Ø 100 mm air ducts.

160 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Centrifugal fans
VENTS CF Series page
Air flow up to 122 m /h
3 162

Centrifugal fans
VENTS CF3 Series page
Air flow up to 90 m3/h 164

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 161


CENTRIFUGAL FANS

VENTS CF Design CF 100 VT – equipped


with a pull cord switch and
Series • Modern design and aesthetic look. a regulated timer with the
• The casing and the impeller are made of high- operating time adjustable from 2 to 30 minutes.
quality durable ABS plastic, UV resistant. CF 100 VTH –
• The easy to use removable grille with a filter equipped with a
element protects the fan internal components pull cord switch,
against grease and dust penetration and makes it regulated timer with the operating time adjustable
suitable for kitchen exhaust ventilation. from 2 to 30 minutes and a humidity sensor with
the operating threshold range from 60 to 90 %.
• The basic CF fan modification includes a dust
filter. Aluminium grease filter configurations are CF 100 TP – equipped with a
also available (CFA model). regulated timer and a motion
sensor with the sensitivity
• The centrifugal fan impeller has forward- area from 1 to 4 m and the detection angle up to
curved blades for high pressure and low noise
100°.
levels.
CF 100 12 – modification with low-
• The centrifugal fan impeller has forward- voltage motor. 12 V AC power supply.
curved blades for high pressure and low noise
levels.
• Protection rating IP24.
Control
Centrifugal fans for exhaust Manual:
Motor
ventilation with the capacity • The fan is controlled by a room light switch. It
up to 122 m3/h • Reliable and low-watt single-phase electric is not included in the delivery package.
motor.
• The fan is controlled by the built-in pull cord
• The basic motor modification includes plain switch V. Not applied in case of ceiling mounting.
Application bearings.
• Speed control is possible through a thyristor
• Continuous or periodic exhaust ventilation • The „turbo“ modification includes the motor speed controller (see Electrical Accessories).
equipped with ball bearings mounted on specially Several fans may connected to the same controller.
of bathroom, showers, kitchens and other utility
designed vibration dampers. Speed controllers can not be connected to the
spaces.
• Ventilation shaft mounting or duct connec- • Designed for continuous operation and fans with T, TH, TP, VT, VTH modification.
requires no maintenance. Automatic:
tion.
• Designed for high-resistance ventilation duct • Equipped with overheating protection. • By the electronic control unit BU-1-60 (see
systems. Electrical Accessories). The control unit is supplied
Modifications and Options separately.
• Compatible with Ø 100 mm air ducts.
CFA – fan with an aluminium grease filter. Mounting features
CF 100 turbo – high-powered motor.
The motor is equipped with ball
• Suitable for external or built-in mounting.

bearings for long service life (appr. • Flexible duct application is recommended in
40 thousand hours) and mounted on specially case of remote location of the ventilation shaft.
designed vibration mounting. The bearings are The air duct is connected to the fan exhaust flange
maintenance-free and contain enough grease for through a clamp.
the entire operating period. • Fixed to wall by self-tapping screws or fixing
CF 100 T – equipped with a regulated brackets.
timer with the operating time from 2 to • Suitable for ceiling mounting.
30 minutes. • For 12 V low-voltage motor fan connection
CF 100 TH – equipped with a to 220 V/50 Hz power mains use the step-down
timer with the operating time transformer TRF 220/12-25 that is available upon
from 2 to 30 minutes and a separate order.
humidity sensor with the threshold value from 60
to 90 %.
CF 100 V – equipped with a pull cord
switch.

Accessories
Air ducts Grilles and hoods Speed controllers Clamps Replaceable filters

162 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Aerodynamic characteristics

Air flow [m3/h]

Technical data

Power
Frequency Current Maximum air Sound Pressure Weight
Model Voltage [V] Consumption R.p.m.
[Hz] [A] flow [m3/h] Level at 3 m [dBA] [kg]
[W]

VENTS CF 100 50/60 220-240 16 0.12 2250 98 36 1.20


VENTS CF 100 turbo 50/60 220-240 29 0.170 2500 122 38 1.30
VENTS CF 100 12 50/60 12 24 3.00 2300 110 37 1.2

Mounting examples Overall dimensions


Dimensions [mm]
Model
ØD B H L L1 L2 L3
VENTS CF 100 100 180 195 132 59 73 26

Wall surface mounting Wall flush mounting

Certificates

The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 163


CENTRIFUGAL FANS

VENTS CF3 Design Control


Series • Modern design and aesthetic look. Manual:

• The casing and the impeller are made of high- • The fan is controlled by the speed switch P3-
quality durable ABS plastic, UV resistant. 1-300 delivered as a standard (CF3 P3 model).
Automatic:
• The easy to use removable grille with a filter
element protects the fan internal components • By the electronic control unit BU-1-60 (see
against grease and dust penetration and makes it Electrical Accessories). The control unit is supplied
suitable for kitchen exhaust ventilation. separately.
• The basic CF3 fan modification includes a dust Mounting features
filter. Aluminium grease filter configurations are
also available (CFA3 model). • Suitable for external or built-in mounting.
• The centrifugal fan impeller has forward- • Flexible duct application is recommended in
curved blades for high pressure and low noise case of remote location of the ventilation shaft.
levels. The air duct is connected to the fan exhaust flange
through a clamp.
• Equipped with a gravitational backdraft
damper for air back flow prevention. • Fixed to wall by self-tapping screws or fixing
brackets.
• Protection rating IP24.
• Suitable for ceiling mounting.
Centrifugal fans Motor
for exhaust ventilation with the
• Reliable and low-watt single-phase three-
capacity up to 90 m3/h speed electric motor.
• Motor equipped with ball bearings mounted
on specially designed vibration dampers.
Application
• Designed for continuous operation and
• Continuous or periodic exhaust ventilation requires no maintenance.
of bathroom, showers, kitchens and other utility
spaces.
• Equipped with overheating protection.

• Ventilation shaft mounting or duct connec-


Modifications and Options
tion.
• Designed for high-resistance ventilation duct CFA3 – fan with an aluminium grease filter
systems. CF3 P3 – fan with a three speed switch.
• Compatible with Ø 100 mm air ducts.

Accessories
Air ducts Grilles and hoods Speed controllers Clamps Replaceable filters

164 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Aerodynamic characteristics Overall dimensions

Dimensions [mm]
Model
ØD B H L L1 L2 L3
VENTS CF3 100 100 180 195 132 59 73 26

Air flow [m3/h]

Technical data

Power Sound Pressure


Frequency Current Maximum air Weight
Model Voltage [V] Consumption R.p.m. Level at 3 m
[Hz] [A] flow [m3/h] [kg]
[W] [dBA]

1 speed 50/60 220-240 13 0.08 825 48 25


VENTS CF3 100 2 speed 50/60 220-240 17 0.11 1010 65 31 1.30
3 speed 50/60 220-240 27 0.16 1593 90 34

Mounting examples

Wall surface mounting Wall flush mounting

Certificates

The fans meet the applicable safety and electromagnetic compatibility standards.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 165


ACCESSORIES FOR DOMESTIC FANS

Back valve Application Mounting

KO series • To prevent air back drafting. • Back valve is mounted on a fan with special
fasteners provided on the fan spigot.
• Does not disturb passive indoor ventilation.
• For domestic fan series VENTS M, M1, D, S, M3, X, X1,
LD, LD Fresh time, Silenta-M, Silenta-S, Modern, Vitro
star, Z star, X star.
• Designed for connection to Ø 100, 125 and
150 mm air ducts.

Design
• Casing made of ABS plastic and the membrane is
made of special light polymer.

Overall dimensions

Dimensions [mm]
Model
ØD a
KO 100 100 14
KO 120 120 14
KO 125 125 14
KO 150 150 14

166 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Window flange Application • Connection to the fan spigot by means of
mounting ribs provides reliable fixation of the
FO Series • The window flange is designed for fan.
mounting of the fans in the window single-
thickness sheet glass, 3-4 mm thick.
• Applicable for all VENTS fans except for
VKO, VKO1, iFan, Quiet, MAO, CF.
• Connecting diameters: 100, 125 and 150
mm.

Mounting

• Fan installation in the window sheet glass.

1
2

1. Fan.
Inner side view.
2. Single window glass.
3. Window flange.

Overall dimensions

Dimensions [mm]
Model
ØD Ø D1 a
FO 100 100 120 25
FO 125 125 147 25
FO 150 150 172 25

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 167


FAN MOUNTING EXAMPLES

Various mounting options for various design features

• VKO and VKO1 Series

• K, K1, PF, PF1, F and F1 Series

• M, M3, MA and MA1 Series

• D, LD, S, X, X1, X Star Series

• MAO Series

• CF Series

168 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Control of built-in fan functions

• Humidity sensor threshold value is adjusted with potentiometer H by turning its


control knob clockwise to increase or counter-clockwise to decrease the humidity
threshold value.

Fan maintenance and cleaning

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 169


FAN MOUNTING EXAMPLES

Wall surface mounting Ceiling mounting

Direct air exhaust through the wall Exhaust ventilation through the ceiling and wall

Wall surface mounting Wall surface mounting

Air exhaust through the ventilation shaft Air exhaust through the wall. For warm air distribution from a
room with a fireplace to adjacent premises

170 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


FAN WIRING DIAGRAMS

Wiring diagram for the fans equipped Wiring diagram for the fans Wiring diagram for the fans equipped
with a built-in switch without built-in switch with a timer / timer, humidity sensor
and a built-in switch

Wiring diagram for the fans equipped Wiring diagram for the fans with Wiring diagram for the fans with
with a timer / timer with a humidity a light lamp. a light lamp. Parallel activation
sensor without built-in switch Separate activation of the fan and the of the fan and the built-in lamp.
built-in lamp.

Wiring diagram for the fans with Wiring diagram for the fans
with a light lamp and grounding. Wiring diagram for the fans
an light lamp and grounding. Separate
Parallel switching of the fan with grounding
activation of the fan and the built-in lamp.
and the built-in lamp.

* – only for fans designed for 12 V rated voltage (specified on the fan casing and packing).
S, S1, S2 – external switches.

Operating logic of the fans with optional equipment


• The fan equipped with a timer is activated by the control voltage supplied to LT input. After the control voltage is disconnected the fan continues operating
within the time period within 2 to 30 minutes according to the timer settings. The turn-off delay time is adjusted by turning the respective potentiometer T
control knob clockwise to increase and counter-clockwise to reduce it.
• The fan equipped with a timer and humidity sensor is activated by the control voltage supplied to LT input or in case of exceeding the preset humidity
threshold value adjustable from ~60 % to ~90 %. After the control voltage is disconnected or as the humidity level H drops below the set threshold the fan
continues operating within the time period within 2 to 30 minutes according to the timer settings. The turn-off delay time and the threshold humidity level
are adjusted by turning the control knob of the respective potentiometer T for timer and H for humidity sensor clockwise to increase and counter-clockwise to
reduce the set value. To set the maximum humidity level (90 %) set the potentiometer control knob for H max position.
• The fan equipped with a timer and motion sensor is activated in case of the moving detection at the distance from 1 m to 4 m with 100° detection angle.
After motion is off the fan continues operating within the time period within 2 to 30 minutes according to the timer settings. The turn-off delay time is adjusted
by turning the respective potentiometer T control knob clockwise to increase and counter-clockwise to reduce it.
• Wiring diagram for connection of the light lamp to the fan timer operated by the common switch is shown on diagram 4. Upon the light lamp disconnection
the fan continues operating according to the timer setting within the set time period.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 171


ELECTRIC ACCESSORIES

MULTI-FUNCTION CONTROL UNITS

TRANSFORMERS SPEED CONTROLLERS

TEMPERATURE REGULATORS SPEED SWITCHES

BACK VALVE

172 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Control unit page
174

Thyristor speed controllers page


175

Autotransformer speed controller page


180

Speed switches for multiple-speed fans page


182

Temperature regulators page


185

Transformers page
188

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 173


CONTROL UNIT

Control unit Application • «Dark mode»: The control unit switches the fan on
after the light is off. The operation duration is adjusta-
BU-1-60 • Automation and control of residential fan opera- ble from 5 sec to 30 min and the photosensor thresh-
tion. It includes automatic controls as timer, humidity
old is set by the regulator.
sensor, photosensor and motion sensor. All these op-
tions can be used in any combination. • «Light mode»: The control unit switches the fan
on after the light is on. As light is off the fan con-
Design tinues operating and turns off as the turn-off delay
timer requires from 5 sec to 30 min. If the light is on
• The control unit casing is made of high-quality more than 60 minutes the fan switches off. The pho-
plastic. tosensor threshold is set by the control unit.
• The front panel is equipped with light indicators • The motion sensor responds to human motion
that display the current operating mode. in the sensitivity area and switches the fan automat-
• Automatic operation with selected mode is possi- ically on. When motion is not registered the control
ble. The switches are used to activate required opera- unit switches the fan off as the turn-off delay timer
tion modes depending on a specific application. The requires from 5 sec to 30 min. Use of the motion sen-
control units are available in several modifications: sor makes the fan control easy and is especially suit-
• Turn-off delay timer keeps the fan running for able for periodically visited premises. The sensitivity
a set time period after turning the built-in or exter- area is 4 m max. and the detection angle up to 100°.
nal switch off that provides extra ventilation in the
premise. The control unit switches the fan off from 5 Mounting
sec to 30 minutes. • The control unit is designed for indoor installation,
• Cyclic timer operation: the cyclic operation both close to the fan and remote. The installation place is
mode allows switching the fan on and off with set selected with respect to the furniture location and walk-
time intervals. Operation or standstill duration is ad- ing routes.
justed from 5 sec to 30 min. The fan switches on and
operates within pre-set time period followed by a
pause according to timer settings. After that the cy-
cle is renewed.
• Humidity sensor switches the fan on as the hu-
midity level in the premise increases above the set
threshold. As it drops back the control unit switches
the fan off. Humidity threshold is user-adjustable.
• Built-in photosensor is sensitive to illumination in
the room and switches the fan automatically on.

S1 X Options
LT humidity motion
L L Model switch timer photosensor
sensor sensor
M
220-240 V B VENTS BU-1-60     
M
N N VENTS BU-1-60 TF  
VENTS BU-1-60 THF   
VENTS BU-1-60 THPF    
S1 S2 X
LT
L L Technical data
M
220-240 V B BU-1-60
M
N N Voltage [V] at 50 Hz 1~ 230
Max. load power [W] 60
Wiring diagram of the control unit
Maximum load current [A] 0.3
Overall dimensions LxBxH [mm] 151x46x27
B – fan; Maximum ambient temperature [oC] +40
S1 – automatic circuit breaker;
S2 – external switch; Protection IP34
X – input terminal block BU. Weight [kg] 0.075

174 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


THYRISTOR SPEED CONTROLLERS

Sensor speed controller Application Mounting

SRS-1 • Applied in ventilation systems for turning the • The controller is designed for indoor mount-
fans on/off and speed control of single-phase ing into standard round electric junction boxes.
voltage controlled fan motors. Several fans can
be connected to one speed controller if their to-
tal current does not exceed the maximum con-
troller current.

Design
• The casing is made of plastic and the sensor
panel is made of hardened glass. The sensor pan-
el has On/Off button for speed control from min-
imum to maximum. The set speed level is dis-
played on the LED display. The speed controller
has high control accuracy.

Technical data:
SRS-1
Voltage [V/50/60 Hz] 230
Maximum load current [A] 1
Cable cross section 0.35 up to 1 mm2
Temperature range [°C] from -10 up to +45
Humidity range 5 % up to 80 % (no condensation)
Service life 100 000 switching operations
Ingress Protection IP30
Weight [g] 138

110-240 V,
50/60 Hz
L

L
Out1
In

М – ventilation equipment motor

Sensor speed controller mounting Wiring diagram

Overall dimensions:

86 31
21 58
11

R1,5
OUT OUT OUT OUT IN
L4 L3 L2 L1 L
4
86

62
52

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 175


THYRISTOR SPEED CONTROLLERS

Speed controller Application • Regulation starts from the minimum to the


maximum voltage value. The maximum speed
RS-1-300 • Used in ventilation systems for switching on/off produces the smoothest rotation.
and speed control of single-phase fan motors with
voltage control. • The minimum speed value is set by a variable
resistor located at the controller control panel.
• Several fans can be controlled from the same
unit in case the total consumption current does not
Protection
exceed the permissible controller current value.
• For overload protection the controller is
Design and control equipped with a replaceable melting fuse.

• The casing is made of plastic.


Mounting
• The controller is featured with high efficiency
• The controller is designed for indoor mounting
and control accuracy.
into special flush mounting junction box MKV-2 (under
• Turn to maximum speed by rotating the control separate order) or into standard round electric junction
knob. boxes.

Technical data
RS-1-300
Voltage [V] at 50 Hz 1~ 230
Rated current [A] 1.5
Overall dimensions LxBxH [mm] 95x85x60
Maximum ambient temperature [°C] 40
Protection IP40
Weight [kg] 0.11

Controller wiring diagram

FLUSH MOUNTING JUNCTION BOX

MKV-2

176 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


THYRISTOR SPEED CONTROLLERS

Speed controller Application • The minimum speed value is set by a variable


resistor located at the controller circuit board.
RS-1-400 • Used in ventilation systems for switching on/
off and speed control of single-phase fan motors
with voltage control.
Protection
• Several fans can be controlled from the same • The input circuit of the speed controller is
equipped with a fuse for overload protection.
unit in case the total consumption current does
not exceed the permissible controller current • The controller is equipped with a transient
value. filter.

Design and control Mounting


• The casing is made of plastic. • The controller is designed for indoor
mounting into special flush mounting (MKN-3)
• The controller is featured with high efficiency
or surface mounting (MKV-4) junction box (under
and control accuracy.
separate order) or into standard round electric
• Turn to maximum speed by rotating the junction boxes.
control knob.
• Regulation starts from the minimum to the
maximum voltage value. The maximum speed
produces the smoothest rotation.

Technical data
RS-1-400
Voltage 50/60 Hz [V] 1~ 230
Rated current [A] 1.8
Overall dimensions LxBxH [mm] 78x78x63
Maximum ambient temperature [°C] 35
Protection IP40
Weight [kg] 0.11

Controller wiring diagram

MOUNTING JUNCTION BOX

MKN-3 (for surface mounting) MKV-3 (for flush mounting)

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 177


THYRISTOR SPEED CONTROLLERS

Speed controller Application Protection


RS-1-0,5 • Used in ventilation systems for switching on/ • The input circuit of the speed controller is
off and speed control of single-phase fan motors equipped with a fuse for overload protection.
with voltage control.
• The controller is equipped with a transient
• Several fans can be controlled from the same filter.
unit in case the total consumption current does
not exceed the permissible controller current Mounting
value.
• The controller is designed for indoor
mounting into special surface mounting (MKN-3)
Design and control or flush mounting (MKV-4) junction box (under
• The casing is made of plastic. separate order) or into standard round electric
• The controller is featured with high efficiency junction boxes.
and control accuracy.
• Turn to maximum speed by rotating the
control knob.
• Regulation starts from the minimum to the
maximum voltage value. The maximum speed
produces the smoothest rotation.
• The minimum speed value is set by a variable
resistor located at the controller circuit board.

Modifications
• RS-1-0,5 – a speed controller without a
mounting junction box.
• RS -1-0,5 N – a speed controller, completed with
a surface mounting junction box.
• RS-1-0,5 V – a speed controller, completed with
a flush mounting junction box.
• RS-1-0,5 NV – a speed controller, completed
with surface and flush mounting junction boxes.

Controller wiring diagram

Technical data

RS-1-0,5
Voltage 50/60 Hz [V] 1~ 230
Rated current [A] 0.5
Overall dimensions LxBxH [mm] 78x78x63
Maximum ambient temperature [°C] 35
Protection IP40
Weight [kg] 0.11

MOUNTING JUNCTION BOX

MKN-3 (for surface mounting) MKV-4 (for flush mounting)

178 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


THYRISTOR SPEED CONTROLLERS

Speed controller Application • The minimum speed value is set by a variable


resistor located at the controller circuit board.
RS-…N (V) • Used in ventilation systems for switching on/off
and speed control of single-phase fan motors with
Protection
voltage control.
• Several fans can be controlled from the same • The input circuit of the speed controller
is equipped with a melting fuse for overload
unit in case the total consumption current does not
protection.
exceed the permissible controller current value.
• The controller is equipped with a transient filter.
Design and control
Mounting
• The controller casing is made of plastic and on/
off button with light indicator. • The regulator is designed for indoor installation.

• The controller is featured with high efficiency • The casing design allows mounting the
and control accuracy. controller on the wall (N modification) or inside the
wall (V modification).
• Regulation starts from the minimum to the
maximum voltage value. The maximum speed
produces the smoothest rotation.

Technical data
RS-1 N (V) RS-1.5 N (V) RS-2 N (V) RS-2,5 N (V)
Voltage [V] at 50 Hz 1~ 230 1~ 230 1~ 230 1~ 230
Rated current [A] 1.0 1.5 2.0 2.5
Overall dimensions LxBxH [mm] 162x80x70 162x80x70 162x80x70 162x80x70
Maximum ambient temperature [oC] 40 40 40 40
Protection IP30 IP30 IP30 IP30
Weight [kg] 0.3 0.3 0.3 0.3

Controller wiring diagram

Speed controller Application • The minimum speed value is set by a variable


resistor located at the controller circuit board.
RS…PS • Used in ventilation systems for switching on/off
and speed control of single-phase fan motors with • Controller is equipped with an extra terminal
voltage control. (230 V) for connection and control of the external
equipment.
• Several fans can be controlled from the same
unit in case the total consumption current does not
exceed the permissible controller current value. Protection
• The input circuit of the speed controller has
Design and control overload protection.
• The casing is made of plastic. • Controller is equipped with a transient filter.
• The control knob is equipped with a light
Mounting
indicator that displays a current operation mode.
• The controller is featured with high efficiency • The controller is suitable for indoor installation
and control accuracy. on the wall.

• Start the controller by pressing the button. • The versatile casing design allows fan mounting
on the wall or inside the wall.
• Regulation starts from the minimum to the
maximum voltage value. The maximum speed • Suitable for installation inside the round junction
produces the smoothest rotation. boxes.

Technical data
RS-0,5-PS RS-1,5-PS RS-2,5-PS RS-4,0-PS
Voltage [V] at 50 Hz 1~ 230 1~ 230 1~ 230 1~ 230
Minimum current [A] 0.1 0.15 0.25 0.4
Maximum current [A] 0.5 1.5 2.5 4.0
Overall dimensions LxBxH [mm] 82x82x65 82x82x65 82x82x65 82x82x65
Maximum ambient temperature [oC] 35 35 35 35
Protection IP44 IP44 IP44 IP44
Weight [kg] 0.23 0.24 0.29 0.36

Controller wiring diagram

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 179


AUTOTRANSFORMER SPEED CONTROLLER

Speed controller Application Protection

RSA-0,3 • RSA speed controller is used for air flow • For overload protection the controller is
control of single-speed fans with low power equipped with a replaceable melting fuse.
consumption by step speed control of electric
motors. Several fans can be controlled from the Mounting
same unit in case the total consumption current
does not exceed the permissible controller
• Transformer speed controller is designed
for indoor installation. Provide sufficient air
current value. circulation for cooling of the internal circuits and
do not install the speed controller above heating
Design equipment.
• The controller casing is made of high-quality
plastic.
• Speed controller has four speeds with output
frequency 160 V – 180 V – 200 V – 230 V. Speed
controller is equipped with on/off light indicator
and control knob for speed switch.

Technical data
RSA-0,3
Voltage [V] at 50 Hz 1~ 230
Output power, no more [VA] 60
Maximum load current [A] 0.3
Overall dimensions LxBxH [mm] 162x80x70
Maximum ambient temperature [oC] +40
Protection IP30
Weight [kg] 0.65

Speed control provides not only the best ventilation mode for periodically visited premises but
considerable reduction of energy consumption.

B – fan;
S – speed controller.

180 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


VENTS. Domestic ventilation. Catalogue №6 | 02-2020 181
SPEED SWITCHES FOR MULTIPLE-SPEED FANS

Sensor speed switch Application vated speed button to turn the ventilation unit off. The ac-
tivated speed button glows blue.
SP3-1 • Applied in ventilation systems for turning the fans
on/off and speed switch of multi-speed fan motors.
Mounting
Design and control • The speed switch is designed for indoor
mounting into special surface mounting box MKN-5
• The casing is made of plastic and is equipped (upon special order) or flush mounting junction box
with a sensor panel made of hardened glass. The
MKV-1 (included).
sensor panel has three speed switch buttons. Press
a respective speed button to activate a required
speed of a connected ventilation unit. Press an acti-

Technical data

SP3-1
Voltage [V/50/60 Hz] 110-240
Maximum load current [A] 1
Cable cross section 0.35 up to 1 mm2
Temperature range [°C] from -10 up to +45
Humidity range 5 % up to 80 % (no condensation)
Service life 100 000 switching operations
Ingress Protection IP30
Weight [g] 138

Sensor speed switch mounting Sensor speed switch mounting

Overall dimensions:
SURFACE MOUNTING JUNCTION BOX
View on mounting side

MKN-5

182 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


SPEED SWITCHES FOR MULTIPLE-SPEED FANS

Speed switch Application Mounting


P2-1-300 • Used for switching the fan on/off and speed • The speed switch is designed for indoor
selection for the fans with multiple-stage fans. installation on the wall inside a flush junction
P3-1-300 mounting box.
Design and control • Suitable for installation inside the round
• The switch casing is made of plastic. junction boxes.
• Both direct speed switching (wiring diagram
1 and 3) and fan switching and speed control in
parallel with light in the room (wiring diagrams
2 and 4).

Technical data
P2-1-300 P3-1-300
Voltage [V] at 50 Hz 1~ 230 1~ 230
Rated current [A] 3.0 3.0
Number of speeds 2 3
Overall dimensions LxBxH [mm] 88x88x51 88x88x51
Maximum ambient temperature [oC] 40 40
Protection IP40 IP40
Weight [kg] 0.13 0.13

SWITCH CONNECTION OPTIONS

diagram 1 diagram 4
The fan can be manually switched ON The fan can be manually switched ON
to one of the three required speeds to one of three speeds by means of the
or switched OFF by means of external external S speed switch as P2-1-300.
speed switch as P3-1-300. When switching the fan ON the light is
switched in parallel ON. The fan can be
switched OFF with parallel switching
the light OFF. The fan operates both
with light or without it.

diagram 2
The fan can be manually switched ON
to one of three speeds by means of such
external S speed switch as P3-1-300. FLUSH MOUNTING JUNCTION BOX
When switching the fan ON the light is
switched in parallel ON. The fan can be
switched OFF with parallel switching
the light OFF. The fan operates both
with light or without it.

diagram 3
The fan can be manually switched ON
to one of the two required speeds or
switched OFF by means of the external MKV-2
speed switch as P2-1-300.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 183


SPEED SWITCHES FOR MULTIPLE-SPEED FANS

Speed switch Application with multi-speed transformer speed controllers.


P5-5,0 speed switch can be connected to transformer
P2-5,0 N(V) • Used for switching the fan on/off and speed speed controller.
selection for the fans with multiple-stage fans.
P3-5,0 N(V) Design and control
Mounting
P5-5,0 N(V) • The switch casing is made of plastic and
• The speed switch is designed for indoor
installation.
equipped with on/off button and operation light
indicator. • The casing design allows mounting on the wall (N
modification) or inside the wall (V modification).
• Speed switch is used either for local speed
switch by rotating a control knob or can be
used as a remote wire control panel connected

Technical data
P2-5,0 P3-5,0 P5-5,0
Voltage [V] at 50 Hz 1~ 230 1~ 230 1~ 230
Rated current [A] 5.0 5.0 5.0
Number of speeds 2 3 5
Overall dimensions LxBxH [mm] 162x80x70 162x80x70 162x80x70
Maximum ambient temperature [oC] 40 40 40
Protection IP30 IP30 IP30
Weight [kg] 0.25 0.25 0.25

B – fan
S – switch
P2-5,0 N(V) P3-5,0 N(V) P5-5,0 N(V)

Speed switch connections

184 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


TEMPERATURE CONTROLLERS

Temperature regulator Application Mounting


RT-10 • Used for temperature control in the room and • Thermostat is designed for indoor wall
control of ventilation, heating and conditioning mounting.
systems.
• The recommended installation height is 1.5 m
from the floor.
Design and control
• Do not install the thermostat close to
• The casing is made of durable casing. windows, doors and heating equipment.
• As the temperature decreases or increases the
thermostat can break or close the contacts. The
operation mode is selected while connection.
• Temperature range from +10 °C to +30 °C.

Technical data
RT-10
Voltage 50/60 Hz [V] 1~ 220-240
Overall dimensions LxBxH [mm] 84x84x35
Maximum ambient temperature [ C] o
40
Protection IP40

Fan operates until it reaches the pre-set Fan starts operation as the temperature reaches
temperature threshold the threshold value set by the thermostat.
fig. 1 fig. 2

Regulator connections

For wiring diagram fig. 1 For wiring diagram fig. 2


– maximum active load current no more 10A – maximum active load current no more 6 A
– maximum inductive load current no more 3A – maximum inductive load current no more 2 A

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 185


TEMPERATURE CONTROLLERS

Temperature controller Application • Due to illuminated LCD display the tempera-


ture controller is suitable for use in bad light con-
RTS-1-400 • Temperature control in ventilation, heating ditions.
and air conditioning systems.
RTSD-1-400 • Compatible with fans and fan coil valves, air
• Temperature control accuracy up to 1 °C.
heating units equipped with three-speed 230 V • Saving of user setting saving in case of pow-
fans. er outage.

• Automatic control of heating/cooling ca- • RTSD-1-400 is available with a remote con-


pacity. trol.
• Night operation mode. For details, refer to the
Design and control night operation mode diagram.
• Plastic casing with a built-in temperature sen-
Mounting
sor.
• The front panel incorporates an integrated • The temperature controller is designed for in-
LCD display and control buttons. door wall flush mounting.

• The display shows current and set indoor air • The recommended installation height is 1.5 m
temperature, set speed and a selected operation above the floor level.
mode. The temperature controller may be set for • The installation place must not be close to
cooling, heating or auto mode. windows, doors and heating or cooling equip-
ment.
• The fan speed is set manually by pressing the
control buttons. • Wall flush mounting in the junction box
MKV-1 (available upon separate order).
• Automatic control of low/medium/high
speed, depending on indoor air temperature.

Technical data
RTS-1-400 RTSD-1-400
Voltage [V] at 50 Hz 1~ 230 1~ 230
Rated current [A] 2.0 2.0
Number of speeds 3 3
Temperature range °C +10…+30 +10…+30
Overall dimensions LxBxH [mm] 88x88x51 88x88x51
Maximum ambient temperature [oC] 40 40
Protection IP40 IP40
Remote control no yes

Night mode operation

• Operation in heating mode: 30 minutes after activation of the night mode the indoor air
temperature drops by 1 °C and by one more 1 °C in the next hour. In the next hour the air temperature
drops by 1 °C more and remains constant for the next 5 hours. After turning the timer off the air
temperature reaches the initial value.
• Operation in cooling mode: 30 minutes after activation of the night mode the indoor air
temperature increases by 1 °C and by one more 1 °C in the next hour and remains constant for the next
6 hours. After turning the timer off the air temperature drops down to the initial value.

186 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


TEMPERATURE CONTROLLERS

Temperature controller
wiring options

Ventilation with Ventilation with


heating and cooling heating and cooling
Three-wire SPDT valve system Two-wire SPST valve system

Operation in night mode

The timer is off.


The timer is off.
The temperature
The temperature
resets to the last set point.
resets to the last set point.

JUNCTION BOX FOR WALL FLUSH MOUNTING

MKV-1

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 187


TRANSFORMERS

Insulating Application Mounting


transformer • Low-voltage step-down transformers are used in • Transformer is designed for indoor installation
humid premises as bathroom and kitchen with low- in areas not subjected to high humidity and
TRF-220/12-25 voltage (12 V) safety requirements. TRF transformers temperature influence.
are used to provide safe power voltage 12 V/ 50 Hz for
the domestic fans not more than 16 W (25VA) with
• Transformer is designed for ceiling flush
mounting or recess wall mounting. In case of
current load up to 2 A. installation into a junction box provide sufficient air
ventilation to prevent the device overheating.
Design
• Observe the applicable fire safety requirements
• Transformer for flush mounting. The trans­ while installation and operation. Do not install
former casing is made of plastic and supplied with a transformers above heating equipment.
protective terminal box. Electrical connection of the
fan with the safe voltage 12 V is done through the
output terminal block.
• For overload protection the transformer is
equipped with a replaceable melting fuse built in the
input terminal board.
• Protection rating (except terminal blocks) IP40.

Technical data
TRF-220/12-25
Voltage [V] at 50 Hz 1~ 230
Output voltage [V] / 50 Hz 12
Max. load power, no more 16 (25 VA)
Maximum load current [A] 2.0
Transformer 91x58x62
Overall dimensions LxBxH [mm]
Terminal box 110x40x40
Maximum ambient temperature [oC] +40
Protection IP40
Weight [kg] 0.8

Transformer wiring diagrams

Q1 – external switch integrated into fixed wiring system;


XT1 – input terminal block with built-in fuse in the protecting terminal box;
XF1 – socket integrated into fixed wiring system;
XM1 – standard wall plug;
T1 – transformer;
XT2 – output terminal block for connection of 12 V fan.
B – low voltage fan, 12 V.

188 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


TRANSFORMERS

Insulating transformer Application KTH – equipped with a timer


with the operating
TRF-220/12-25 K • Low-voltage step-down transformers are time from 2 to 30 minutes and
used in humid premises as bathroom and kitchen
TRF-220/12-25 KV with low-voltage (12 V) safety requirements. TRF a humidity sensor with the
threshold value from 60 to 90 %.
transformers are used to provide safe power
voltage 12 V/ 50 Hz for the domestic fans not KTP – equipped with a
more than 16 W (25VA) with current load up to regulated timer and a motion
2 A. sensor with the sensitivity
area from 1 to 4 m and the
Design detection angle up to 100°.
• TRF-220/12-25 K transformer in plastic casing
for wall mounting.
Mounting
• TRF-220/12-25 KV transformer in plastic
casing for wall mounting with a built-in switch. • Transformer is designed for indoor installation
The casing is equipped with a light indicator. in areas not subjected to high humidity and
temperature influence.
• For overload protection the transformer is
equipped with a replaceable melting fuse. • Transformer is designed for wall mounting.
Provide sufficient air circulation for cooling of the
internal circuits.
Modifications and options • Observe the applicable fire safety
requirements while installation and operation.
Do not install transformers above heating
KV – equipped with a pull cord switch. equipment.

KT – equipped with a regulated timer


with the operating time from 2 to 30
minutes.

Technical data
TRF-220/12-25 K
Voltage [V] at 50 Hz 1~ 230
Output voltage [V] / 50 Hz 12
Max. load power, no more 16 (25VA)
Maximum load current [A] 2.0
Overall dimensions LxBxH [mm] 80x162x63
Maximum ambient temperature [oC] +40
Protection IP30
Weight [kg] 0.85

TRF-220/12-25 K TRF-220/12-25 KV

TRF-220/12-25 KT / KTH TRF-220/12-25 KTP

Transformer wiring diagrams

B – low voltage fan, 12 V;


T – protective transformer;
S – external switch.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 189


AIR DISTRIBUTION UNITS

190 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


SUPPLY AND EXHAUST GRILLES page
MV 100 Series 194

SUPPLY AND EXHAUST GRILLES page


MV 101 Series 196

SUPPLY AND EXHAUST GRILLES page


MV 120 Series 198

SUPPLY AND EXHAUST GRILLES page


MV 121 Series 200

SUPPLY AND EXHAUST GRILLES page


MV 125, MV 125-1 Series 202

SUPPLY AND EXHAUST GRILLES page


MV 126, MV 126-1 Series 204

SUPPLY AND EXHAUST GRILLES page


MV 150 V Series 204

SUPPLY AND EXHAUST GRILLES page


MV 151 V Series 207

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 191


SUPPLY AND EXHAUST GRILLES page
MV 150, MV 150-1 Series 208

SUPPLY AND EXHAUST GRILLES page


MV 160 Series 210

SUPPLY AND EXHAUST GRILLES page


MV 170 Series 211

SUPPLY AND EXHAUST GRILLES page


MV 250, MV 250-1 Series 212

SUPPLY AND EXHAUST GRILLES page


MV 80-1 Series 215

SUPPLY AND EXHAUST GRILLES page


Single-element MV Series (from MV 150x150 to MV 350x350) 216

SUPPLY AND EXHAUST ROUND GRILLES page


MV 50 bV, MV 51 bV 217

SUPPLY AND EXHAUST ROUND GRILLES page


MV 52 bV Series 218

SUPPLY AND EXHAUST ROUND GRILLES page


MV 80 bV, MV 81 bV Series 219

192 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


SUPPLY AND EXHAUST ROUND GRILLES page
MV 100 bV, MV 125 bV, MV 150 bV Series 220

OUTER VENTILATION HOOD page


MVVM 162 Series 221

SUPPLY AND EXHAUST HOODS page


MV 102, MV 122, MV 152 Series 222

EXHAUST GRILLES page


MV 100 J Series 224

EXHAUST GRILLES page


MV 120 J, MV 150 VJ Series 225

EXHAUST GRILLES page


MV 160 J Series 226

EXHAUST GRILLES page


MV 250 J Series 227

EXHAUST GRILLES page


MV 100 K, MV 125 K Series 228

EXHAUST GRILLES page


MV 100 KV, MV 120 KV, MV 125 KV Series 229

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 193


SUPPLY AND EXHAUST
PLASTIC GRILLES

MV 100 Application
Series • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.
• Used for correct air flow distribution in premises.
• Wall or ceiling mounting.

Design
• Made of quality and durable plastic.
• Multi-element structure. The internal part is fixed to the base with latches for easy cleaning without
dismantling.
• Screw fixing.
• The grille has slanted vanes.

Colour modifications

white brown grey beige mahogany lightwood black

Modifications

MV 100 – basic modification

• Wall or ceiling mounting.


• MV 100 s – model with a protecting insect screen.

MV 100 R – model with air flow regulator (R)

• Equipped with a movable flap for air flow regulation.


• Air pass is regulated with a tilt wand or pull cords.
• MV 100 Rs – model with air flow regulator and a protecting insect screen.

MV 100 V – model with a round flange (V)

• Fitted with a round connecting flange for mounting with Ø 100 mm


air duct.
• Suitable for direct mounting with VENTS VKO 100 fan.
• MV 100 Vs – model with a round flange and a protecting insect
screen.

194 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


MV 100 VR – model with a round flange and air flow regulator (VR)

• Fitted with a round connecting flange for mounting with Ø100 mm air duct.
• Equipped with a movable flap for air flow regulation.
• Air pass is regulated with a tilt wand or pull cords.
• Suitable for direct mounting with VENTS VKO 100 fan.
• MV 100 VRs – model with a round flange, air flow regulator and a  protecting
insect screen.

MV 100 VU – model with a multi-section flange (VU)

• Equipped with a multi-section connecting flange for mounting with Ø100, 125 mm
or 55x110 mm air duct.
• MV 100 VUs – model with a multi-section flange and a protecting insect screen.

MV 100 VUR – model with a multi-section flange and air flow regulator (VUR)

• Equipped with a multi-section connecting flange for mounting with Ø100, 125 mm
or 55x110 mm air duct.
• Equipped with a movable flap for air flow regulation.
• Air pass is regulated with a tilt wand or pull cords.
• MV 100 VURs – model with a multi-section flange, air flow regulator and a protecting
insect screen.

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2] Fig. no.
 B  H L L1 Flange (D)

MV 100 154 110 15 – – 0.0067 1, 2


MV 100 R 154 110 15 – – 0.0049 1, 2
MV 100 V 154 110 15 45 100 0.004 1, 3
MV 100 VR 154 110 15 45 100 0.0037 1, 3
MV 100 VU 154 110 15 39 100, 125, 55x110 0.0067 1, 4
MV 100 VUR 154 110 15 39 100, 125, 55x110 0.0049 1, 4

Fig. 1 Fig. 2 Fig. 3 Fig. 4

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 195


SUPPLY AND EXHAUST
PLASTIC GRILLES

MV 101 Application
Series • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.
• Used for correct air flow distribution in premises.
• Wall or ceiling mounting.

Design
• Made of quality and durable plastic.
• Multi-element structure. The internal part is fixed to the base with latches for easy cleaning without
dismantling.
• Screw fixing.
• The grille has straight vanes to increase air pass.

Colour modifications

white brown grey beige mahogany lightwood black

Modifications

MV 101 – basic modification

• Wall or ceiling mounting


• MV 101 s – model with a protecting insect screen.

MV 101 R – model with an air flow regulator (R)

• Equipped with a movable flap for air flow regulation.


• Air pass is regulated with a tilt wand or pull cords.
• MV 101 Rs – model with air flow regulator and a protecting insect screen.

MV 101 V – model with a round flange (V)

• Fitted with a round connecting flange for mounting with Ø 100 mm air duct.
• Suitable for direct mounting with VENTS VKO 100 fan.
• MV 101 Vs – model with a round flange and a protecting insect screen.

196 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


MV 101 VR – model with a round flange and air flow regulator (VR)

• Fitted with a round connecting flange for mounting with Ø100 mm air duct.
• Equipped with a movable flap for air flow regulation.
• Air pass is regulated with a tilt wand or pull cords.
• Suitable for direct mounting with VENTS VKO 100 fan.
• MV 101 VRs – model with a round flange, air flow regulator and a protecting insect
screen.

MV 101 VU – model with a multi-section flange (VU)

• Equipped with a multi-section connecting flange for mounting with Ø 100, 125 mm or
55x110 mm air duct.
• MV 101 VUs – model with a multi-section flange and a protecting insect screen.

MV 101 VUR – model with a multi-section flange and air flow regulator (VUR)

• Equipped with a multi-section connecting flange for mounting with Ø 100, 125 mm or
55x110 mm air duct.
• Equipped with a movable flap for air flow regulation.
• Air pass is regulated with a tilt wand or pull cords.
• MV 101 VURs – model with a multi-section flange, air flow regulator and a protecting
insect screen.

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2] Fig. no.
 B H L L1 Flange (D)

MV 101 154 110 19 – – 0.0089 1, 2


MV 101 R 154 110 19 – – 0.005 1, 2
MV 101 V 154 110 19 49 100 0.0079 1, 3
MV 101 VR 154 110 19 49 100 0.0044 1, 3
MV 101 VU 154 110 19 43 100, 125, 55x110 0.0089 1, 4
MV 101 VUR 154 110 19 43 100, 125, 55x110 0.005 1, 4

Fig. 1 Fig. 2 Fig. 3 Fig. 4

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 197


SUPPLY AND EXHAUST
PLASTIC GRILLES

MV 120 Application
Series • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.
• Used for correct air flow distribution in premises.
• Wall or ceiling mounting.

Design
• Made of quality and durable plastic.
• Multi-element structure. The internal part is fixed to the base with latches for easy cleaning without
dismantling.
• Screw fixing.
• The grille has slanted vanes.

Colour modifications

white brown grey beige mahogany lightwood black

Modifications

MV 120 – basic modification

• Wall or ceiling mounting.


• MV 120 s – model with a protecting insect screen.

MV 120 R – model with an air flow regulator (R)

• Equipped with a movable flap for air flow regulation.


• Air pass is regulated with a tilt wand or pull cords.
• MV 120 Rs – model with air flow regulator and a protecting insect screen.

MV 120 V – model with a round flange (V)

• Fitted with a round connecting flange for mounting with Ø 125 mm air duct.
• Suitable for direct mounting with VENTS VKO 125 fan.
• MV 120 Vs – model with a round flange and a protecting insect screen.

198 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


MV 120 VR – model with a round flange and air flow regulator (VR)

• Fitted with a round connecting flange for mounting with Ø 125 mm air duct.
• Equipped with a movable flap for air flow regulation.
• Air pass is regulated with a tilt wand or pull cords.
• Suitable for direct mounting with VENTS VKO 125 fan.
• MV 120 VRs – model with a round flange, air flow regulator and a protecting insect
screen.

MV 120 VN – model with a flange with various diameters (VN)

• Fitted with a round connecting flange for mounting with Ø 100/110/120/130/150 mm


air duct.
• MV 120 VNs – model with a round flange with various diameters and a protecting insect
screen.

MV 120 VNR – model with a flange with various diameters and air flow regulator (VNR)

• Fitted with a round connecting flange for mounting with Ø 100/110/120/130/150 mm


air duct.
• Equipped with a movable flap for air flow regulation.
• Air pass is regulated with a tilt wand or pull cords.
• MV 120 VNRs – model with a round variable diameter flange, air flow regulator and a
protecting insect screen.

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2] Fig. no.
 B  H L L1 D

MV 120 186 142 15 – – 0.0115 1, 2


MV 120 R 186 142 15 – – 0.0062 1, 2
MV 120 V 186 142 15 45 125 0.0083 1, 3
MV 120 VR 186 142 15 45 125 0.0044 1, 3
MV 120 VN 186 142 15 115 100-150 0.009 1, 4
MV 120 VNR 186 142 15 115 100-150 0.0051 1, 4

Fig. 1 Fig. 2 Fig. 3 Fig. 4

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 199


SUPPLY AND EXHAUST
PLASTIC GRILLES

MV 121 Application
Series • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.
• Used for correct air flow distribution in premises.
• Wall or ceiling mounting.

Design
• Made of quality and durable plastic.
• Multi-element structure. The internal part is fixed to the base with latches for easy cleaning without
dismantling.
• Screw fixing.
• The grille has straight vanes to increase air pass.

Colour modifications

white brown grey beige mahogany lightwood black

Modifications

MV 121 – basic modification

• Wall or ceiling mounting.


• MV 121 s – model with a protecting insect screen.

MV 121 R – model with an air flow regulator (R)

• Equipped with a movable flap for air flow regulation.


• Air pass is regulated with a tilt wand or pull cords.
• MV 121 Rs – model with air flow regulator and a protecting insect screen.

MV 121 V – model with a round flange (V)

• Fitted with a round connecting flange for mounting with Ø 125 mm air duct.
• Suitable for direct mounting with VENTS VKO 125 fan.
• MV 121 Vs – model with a round flange and a protecting insect screen.

200 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


MV 121 VR – model with a round flange and air flow regulator (VR)

• Fitted with a round connecting flange for mounting with Ø 125 mm air duct.
• Equipped with a movable flap for air flow regulation.
• Air pass is regulated with a tilt wand or pull cords.
• Suitable for direct mounting with VENTS VKO 125 fan.
• MV 121 VRs – model with a round flange, air flow regulator and a protecting insect
screen.

MV 121 VN – model with a flange with various diameters (VN)

• Fitted with a round connecting flange with various diameters for mounting with
Ø 100/110/120/130/150 mm air duct.
• MV 121 VNs – model with a round flange with various diameters and a protecting
insect screen.

MV 121 VNR – model with a flange with various diameters and air flow regulator (VNR)

• Fitted with a round connecting flange with various diameters for mounting with
Ø 100/110/120/130/150 mm air duct.
• Equipped with a movable flap for air flow regulation.
• Air pass is regulated with a tilt wand or pull cords.
• MV 121 VNRs – model with a round flange with various diameters, air flow
regulator and a protecting insect screen.

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2] Fig. no.
 B H L L1 D

MV 121 186 142 19 – – 0.0155 1, 2


MV 121 R 186 142 19 – – 0.0083 1, 2
MV 121 V 186 142 19 49 125 0.0123 1, 3
MV 121 VR 186 142 19 49 125 0.0066 1, 3
MV 121 VN 186 142 19 119 100-150 0.0123 1, 4
MV 121 VNR 186 142 19 119 100-150 0.0066 1, 4

Fig. 1 Fig. 2 Fig. 3 Fig. 4

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 201


SUPPLY AND EXHAUST
PLASTIC GRILLES

MV 125 Application
Series • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.
• Used for correct air flow distribution in premises.
• Wall or ceiling mounting.

Design
• Made of quality and durable plastic.
• Multi-element structure. The internal part is fixed to the base with latches for easy cleaning without
dismantling.
• Fixing with screw or lugs depending on modification.

Colour modifications

white brown grey beige mahogany lightwood black

Modifications

MV 125 – basic modification

• Screw fixing.
• MV 125 s – model with a protecting screen and screw fixing.
• MV 125 M – model with fixing lugs.
• MV 125 Ms – model with fixing lugs and a protecting insect screen.

MV 125 VD – model with four-element connecting flange (VD)

• Screw fixing.
• Equipped with four-element connecting flange with adjustable diameter for
connection to Ø 100-150 mm round air duct.
• MV 125 VDS – grille model with screw fixing and a protecting insect screen.
• MV 125 VDM – grille model with fixing lugs.
• MV 125 VDMs – grille model with fixing lugs and a protecting insect screen.

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2] Fig. no.
H B L L1 H1 B1 D
MV 125 251 182 16 – 226 157 – 0.0127 1, 2
MV 125 VD 251 182 16 41 226 157 100-150 0.0127 1, 3

Fig. 1 Fig. 2 Fig. 3

202 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


SUPPLY AND EXHAUST
PLASTIC GRILLES

MV 125-1 Application
Series • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.
• Used for correct air flow distribution in premises.
• Wall or ceiling mounting.

Design
• Made of quality and durable plastic.
• Single-element structure. Modification may include a protecting insect screen.
• Fixing with glue or silicon.

Colour modifications

white brown grey beige mahogany lightwood black

Modifications

MV 125-1 – single-element model

• Wall or ceiling mounting.


• Fixing with glue or silicon.
• MV 125-1 s – model with a protecting insect screen.

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2]
H B L
MV 125-1 238 170 8 0.0127

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 203


SUPPLY AND EXHAUST
PLASTIC GRILLES

MV 126 Application
Series • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.
• Used for correct air flow distribution in premises.
• Wall or ceiling mounting.

Design
• Made of quality and durable plastic.
• Multi-element structure. The internal part is fixed to the base with latches for easy cleaning
without dismantling.
• Fixing with screws or lugs depending on grille modification.

Colour modifications

white brown grey beige mahogany lightwood black

Modifications

MV 126 – basic modification

• Screw fixing.
• MV 126 s – model with screw fixing and a protecting insect screen.
• MV 126 M – model with fixing lugs.
• MV 126 Ms – model with fixing lugs and a protecting insect screen.

MV 126 VD – model with four-element connecting flange (VD)

• Screw fixing.
• Equipped with four-element connecting flange with adjustable diameter
for connection to Ø 100-150 mm round air duct.
• MV 126 VDs – model with screw fixing and a protecting insect screen.
• MV 126 VDM – model with fixing lugs.
• MV 126 VDMs – model with fixing lugs and a protecting insect screen.

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2] Fig. no.
H B L L1 H1 B1 D
MV 126 251 182 19.5 – 226 157 – 0.018 1, 2
MV 126 VD 251 182 19.5 45 226 157 100-150 0.018 1, 3

Fig. 1 Fig. 2 Fig. 3

204 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


SUPPLY AND EXHAUST
PLASTIC GRILLES

MV 126-1 Application
Series • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.
• Used for correct air flow distribution in premises.
• Wall or ceiling mounting.

Design
• Made of quality and durable plastic.
• Single-element structure. Modification may include a protecting insect screen.
• Fixing with glue or silicon.

Colour modifications

white brown grey beige mahogany lightwood black

Modifications

MV 126-1 – single-element structure

• Wall or ceiling mounting.


• Fixing with glue or silicon.
• MV 126-1 s – model with a protecting insect screen.

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2]
H B L
MV 126-1 238 170 13.5 0.018

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 205


SUPPLY AND EXHAUST
PLASTIC GRILLES

MV 150 V Application
Series • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.
• Used for correct air flow distribution in premises.
• Wall or ceiling mounting.

Design
• Made of quality and durable plastic.
• Multi-element structure. The internal part is fixed to the base with latches for easy cleaning without
dismantling.
• Screw fixing.
• The grille has slanted vanes.

Colour modifications

white brown grey beige mahogany lightwood black

Modifications

MV 150 V – model with a round flange (V)

• Fitted with a round connecting flange for mounting with Ø 150 mm air duct.
• Suitable for direct mounting with VENTS VKO 150 fan.
• MV 150 Vs – model with a round flange and a protecting insect screen.

MV 150 VR – model with a round flange and air flow regulator (VR)

• Fitted with a round connecting flange for mounting with Ø 150 mm air duct.
• Equipped with a movable flap for air flow regulation.
• Air pass is regulated with a tilt wand or pull cords.
• Suitable for direct mounting with VENTS VKO 150 fan.
• MV 150 VRs – model with a round flange, air flow regulator and a protecting insect
screen.

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2] Fig. no.
 B  H L L1 D

MV 150 V 186 142 15 50 150 0.0083 1, 2


MV 150 VR 186 142 15 50 150 0.0044 1, 2

Fig. 1 Fig. 2

206 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


SUPPLY AND EXHAUST
PLASTIC GRILLES

MV 151 V Application
Series • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.
• Used for correct air flow distribution in premises.
• Wall or ceiling mounting.

Design
• Made of quality and durable plastic.
• Multi-element structure. The internal part is fixed to the base with latches for easy cleaning without
dismantling.
• Screw fixing.
• The grille has straight vanes to increase air pass.

Colour modifications

white brown grey beige mahogany lightwood black

Modifications

MV 151 V – model with a round flange (V)

• Fitted with a round connecting flange for mounting with Ø 150 mm air duct.
• Suitable for direct mounting with VENTS VKO 150 fan.
• MV 151 Vs – model with a round flange and a protecting insect screen.

MV 151 VR – model with a round flange and air flow regulator (VR)

• Fitted with a round connecting flange for mounting with Ø 150 mm air duct.
• Equipped with a movable flap for air flow regulation.
• Air pass is regulated with a tilt wand or pull cords.
• Suitable for direct mounting with VENTS VKO 150 fan.
• MV 151 VRs – model with a round flange, air flow regulator and a protecting insect
screen.

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2] Fig. no.
 B  H L L1 D

MV 151 V 186 142 19 54 150 0.0123 1, 2


MV 151 VR 186 142 19 54 150 0.0066 1, 2

Fig. 1 Fig. 2

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 207


SUPPLY AND EXHAUST
PLASTIC GRILLES

MV 150 Application
Series • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.
• Used for correct air flow distribution in premises.
• Wall or ceiling mounting.

Design
• Made of quality and durable plastic.
• Multi-element structure. The internal part is fixed to the base with latches for easy cleaning without
dismantling.
• Fixing with screws or lugs depending on grille modification.

Colour modifications

white brown grey beige mahogany lightwood black

Modifications

MV 150 – basic modification

• Screw fixing.
• MV 150 s – model with a protecting insect screen and screw fixing.
• MV 150 M – model with fixing lugs.
• MV 150 Ms – model with fixing lugs and a protecting insect screen.

MV 150 VD – model with four-element connecting flange

• Screw fixing.
• Equipped with four-element connecting flange with adjustable diameter for connection to Ø
100-150 mm round air duct.
• MV 150 VDs – model with four-element connecting flange, screw fixing and a protecting
insect screen.
• MV 150 VDM – model with four-element connecting flange and fixing lugs.
• MV 150 VDMs – model with four-element connecting flange, fixing lugs and a protecting
insect screen.

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2] Fig. no
B H L L1 D
MV 150 204 179 16 – – 0.0092 1, 2
MV 150 VD 204 179 16 41 100-150 0.0092 1, 3

Fig. 1 Fig. 2 Fig. 3

208 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


SUPPLY AND EXHAUST
PLASTIC GRILLES

MV 150-1 Application
Series • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.
• Used for correct air flow distribution in premises.
• Wall or ceiling mounting.

Design
• Made of quality and durable plastic.
• Multi-element structure. The internal part is fixed to the base with latches for easy cleaning without
dismantling.
• Fixing with glue or silicon.

Colour modifications

white brown grey beige mahogany lightwood black


Modifications

MV 150-1 – single-element model

• Wall or ceiling mounting.


• Fixing with glue or silicon.
• MV 150-1 s – model with a protecting insect screen.

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2]
B L
MV 150-1 192 8 0.0092

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 209


SUPPLY AND EXHAUST
PLASTIC GRILLES

MV 160 Application
Series • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.
• Used for correct air flow distribution in premises.
• Wall or ceiling mounting.

Design
• Made of quality and durable plastic.
• Multi-element structure. The internal part is fixed to the base with latches for easy cleaning without
dismantling.
• Fixing with screws or lugs depending on grille modification.

Colour modifications

white brown grey beige mahogany lightwood black

Modifications

MV 160 – basic modification

• Screw fixing.
• MV 160 s – model with a protecting insect screen and screw fixing.
• MV 160 M – model with fixing lugs.
• MV 160 Ms – model with fixing lugs and a protecting insect screen.

MV 160 VD – model with four-element connecting flange (VD)

• Screw fixing.
• Equipped with four-element connecting flange with adjustable diameter for connection to Ø
100-150 mm round air duct.
• MV 160 VDs – model with four-element connecting flange and a protecting insect screen.
• MV 160 VDM – model with four-element connecting flange and fixing lugs.
• MV 160 VDMs – model with four-element connecting flange, fixing lugs and a protecting
insect screen.

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2] Fig. no.
H B L L1 H1 B1 D
MV 160 299 221 15 – 283 205 – 0.026 1, 2
MV 160 VD 299 221 15 42 283 205 100-150 0.026 1, 3

Fig. 1 Fig. 2 Fig. 3

210 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


SUPPLY AND EXHAUST
PLASTIC GRILLES

MV 170 Application
Series • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.
• Used for correct air flow distribution in premises.
• Wall or ceiling mounting.

Design
• Made of quality and durable plastic.
• Multi-element structure. The internal part is fixed to the base with latches for easy cleaning without
dismantling.
• Screw fixing.

Colour modifications

Modifications white brown grey beige mahogany lightwood black

MV 170 – basic modification

• Wall or ceiling mounting.


• MV 170 s – model with a protecting insect screen.

MV 170 R – model with an air flow regulator (R)

• Equipped with a movable flap for air flow regulation.


• Air pass is regulated with a tilt wand or pull cords.
• MV 170 Rs – model with air flow regulator and a protecting insect screen.

MV 170 VD – model with four-element connecting flange (VD)

• Equipped with four-element connecting flange with adjustable diameter for


connection to Ø 100-150 mm round air duct.
• MV 170 VDs – model with four-element connecting flange and a protecting
insect screen.

MV 170 VDR – model with four-element connecting flange and air flow regulator

• Equipped with four-element connecting flange with adjustable diameter for


connection to Ø 100-150 mm round air duct.
• Equipped with a movable flap for air flow regulation.
• Air pass is regulated with a tilt wand or pull cords.
• MV 170 VDRs – model with four-element connecting flange, air flow regulator
and a protecting insect screen.

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2] Fig. no.
H B L L1 H1 B1 D
MV 170 221 299 15 – 205 283 – 0.0237 1
MV 170 VD 221 299 15 42 205 283 100-150 0.018 1, 2
MV 170 R 221 299 15 – 205 283 – 0.012 1
MV 170 VDR 221 299 15 42 205 283 100-150 0.088 1, 2 Fig. 1 Fig. 2

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 211


SUPPLY AND EXHAUST
PLASTIC GRILLES

MV 250 Application
Series • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.
• Used for correct air flow distribution in premises.
• Wall or ceiling mounting.

Design
• Made of quality and durable plastic.
• Multi-element structure. The internal part is fixed to the base with latches for easy cleaning without
dismantling.
• Fixing with screws or lugs depending on grille modification.

Colour modifications

white brown grey beige mahogany lightwood black

Modifications

MV 250 – basic modification

• Screw fixing.
• MV 250 s – model with a protecting insect screen and screw fxing.
• MV 250 M – model with fixing lugs.
• MV 250 Ms – model with fixing lugs and a protecting insect screen.

MV 250 R – model with an air flow regulator (R)

• Equipped with a movable flap for air flow regulation.


• Air pass is regulated with a tilt wand or pull cords.
• MV 250 Rs – model with air flow regulator and a protecting insect screen.

MV 250/150 V – model with a round Ø 150 mm flange

• Wall or ceiling mounting.


• Fitted with a round connecting flange for mounting with Ø 150 mm air duct.
• Suitable for direct mounting with VENTS VKO 150 fan.
• Screw fixing.
• MV 250/150 Vs – model with a round flange and a protecting insect screen.

MV 250/200 V – model with a round Ø 200 mm flange

• OFitted with a round connecting flange for mounting with Ø 200 mm air duct.
• Screw fixing.
• MV 250/200 Vs – model with a round flange and a protecting insect screen.

212 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


MV 250/150 VR – model with a round Ø 150 mm flange and air flow regulator (VR)

• Fitted with a round connecting flange for mounting with Ø 150 mm air duct.
• Equipped with a movable flap for air flow regulation.
• Air pass is regulated with a tilt wand or pull cords.
• Suitable for direct mounting with VENTS VKO 150 fan.
• MV 250/150 VRs – model with a round flange, air flow regulator and a protecting insect
screen.

MV 250/200 VR – model with a round Ø 200 mm flange and air flow regulator (VR)
• Fitted with a round connecting flange for mounting with Ø 200 mm air duct.
• Equipped with a movable flap for air flow regulation.
• Air pass is regulated with a tilt wand or pull cords.
• Screw fixing.
• MV 250/200 VRs – model with a round flange, air flow regulator and a protecting insect
screen.

MV 250 VD – model with four-element connecting flange

• Equipped with four-element connecting flange with adjustable diameter for connection
to Ø 100-150 mm round air duct.
• Screw fixing.
• MV 250 VDs – model with four-element flange and a protecting insect screen.

MV 250 VDR – model with four-element flange and air flow regulator (VDR)

• Equipped with four-element connecting flange with adjustable diameter for connection
to Ø 100-150 mm round air duct.
• Equipped with a movable flap for air flow regulation.
• Air pass is regulated with a tilt wand or pull cords.
• Screw fixing.
• MV 250 VDRs – model with four-element flange, air flow regulator and a protecting insect
screen.

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2] Fig. no.
 H  B L L1 D
MV 250 250 214 14 – – 0.02 1, 2
MV 250 R 250 214 14 – – 0.01 1, 2
MV 250/150 V 250 214 14 44 150 0.02 1, 3
MV 250/200 V 250 214 14 44 200 0.02 1, 3
MV 250/150 VR 250 214 14 44 150 0.01 1, 3
MV 250/200 VR 250 214 14 44 200 0.01 1, 3
MV 250 VD 250 214 14 42 100-150 0.02 1, 4
MV 250 VDR 250 214 14 42 100-150 0.01 1, 4

Fig. 1 Fig. 2 Fig. 3 Fig. 4

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 213


SUPPLY AND EXHAUST
PLASTIC GRILLES

MV 250-1 Application
Series • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.
• Used for correct air flow distribution in premises.
• Wall or ceiling mounting.

Design
• Made of quality and durable plastic.
• Multi-element structure. The internal part is fixed to the base with latches for easy cleaning without
dismantling.
• Fixing with glue or silicon.
• Modifications with a protecting insect screen are available.

Colour modifications

white brown grey beige mahogany lightwood black

Modifications

MV 250-1 – basic modification

• Wall or ceiling mounting.


• MV 250-1 s – model with a protecting insect screen.
• Fixing with glue or silicon.

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2]
H B L
MV 250-1 230 230 8 0.02

214 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


SUPPLY AND EXHAUST
PLASTIC GRILLES

MV 80-1 Application
Series • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.
• Used for correct air flow distribution in premises.
• Wall or ceiling mounting.

Design
• Made of quality and durable plastic.
• Multi-element structure. The internal part is fixed to the base with latches for easy cleaning without
dismantling.
• Fixing with glue or silicon.
• Modifications with a protecting insect screen are available.

Colour modifications

white brown grey beige mahogany lightwood black

Modifications

MV 80-1 – basic modification

• Wall or ceiling mounting.


• MV 80-1 s – model with a protecting insect screen.
• Fixing with glue or silicon.

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2]
H B L
MV 80-1 80 170 7 0.0039

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 215


SUPPLY AND EXHAUST
PLASTIC GRILLES

MV Series Application
single-element • Decoration of supply and exhaust vents of public, residential and
industrial ventilation systems.
• Used for correct air flow distribution in premises.
• Wall or ceiling mounting.

Design
• Made of quality and durable plastic.
• Single-element structure.
• Various fixing modifications depending on the model type: screws, lugs
or glue (silicon).
• Grille modifications with an insect screen.

Colour modifications

white brown grey beige mahogany lightwood black

Fixation options

Glue (silicone): MV Screws: MV Fixing lugs: MV…M

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2]
H B L
MV 150x150 150 150 11 0.0058
MV 175x175 175 175 11 0.0089
MV 205x205 205 205 11 0.0135
MV 215x175 215 175 11 0.0115
MV 250x180 250 180 11 0.0141
MV 250x250 250 250 11 0.0213
MV 295x160 295 160 11 0.0147
MV 300x205 300 205 11 0.0207
MV 300x300 300 300 11 0.0302
MV 350x350 350 350 11 0.0432

216 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


SUPPLY AND EXHAUST
PLASTIC GRILLES

MV 50 bV MV 51 bV Application
Series Series • Suitable for installation in furniture, bathroom and kitchen door leaves, etc.
• Used to arrange correct air circulation in premises.

Design
• Made of quality and durable plastic.
• Fixed with mounting ribs or glue.

Colour modifications

white brown grey beige mahogany lightwood black

Modifications

MV 50 bV – round model with a flange (bV)

• Round model with Ø 47 mm flange.


• Minimum door leaf thickness is 28 mm
• MV 50 bVs – model with a protecting insect screen.

MV 51 bV – round model with a flange (bV)

• Round model with Ø 47 mm flange.


• Minimum door leaf thickness is 28 mm
• MV 51 bVs – model with a protecting insect screen.

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2] Fig.no.
D D1 D2 L L1
MV 50 bV 59 47 – 3.5 16.5 0.00078 1
MV 51 bV 59 47 – 3 16 0.00078 2

Fig. 1 Fig. 2

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 217


SUPPLY AND EXHAUST
PLASTIC GRILLES

MV 52 bV Application
Series • Suitable for installation in furniture, bathroom and kitchen door leaves, etc.
• Used to arrange correct air circulation in premises.

Design
• Made of quality and durable plastic.
• Fixed with mounting ribs or glue.

Colour modifications

white brown grey beige mahogany lightwood black

Modifications

MV 52 bV – round model with a flange (bV)

• Round model with Ø 41 mm flange.


• Minimum door leaf thickness is 37 mm
• The complete set includes two items.
• The grilles are connected with slots.

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2]
D D1 D2 L L1
MV 52 bV 56 40 26 41.5 – 0.00053

218 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


SUPPLY AND EXHAUST
PLASTIC GRILLES

MV 80 bV MV 81 bV Application
Series Series • Decoration of supply and exhaust vents of public, residential and
industrial ventilation systems.
• Wall or ceiling mounting.
• Suitable for installation in furniture, bathroom and kitchen door leaves,
etc.

Design
• Made of quality and durable plastic.
• Fixed with mounting ribs or glue.

Colour modifications

white brown grey beige mahogany lightwood black

Modifications

MV 80 bV – model with a round flange (bV)

• Equipped with a round flange for connection with Ø 80 mm air duct.


• MV 80 bVs – model with a protecting insect screen.

MV 81 bV – round model with a flange

• Equipped with a round flange for connection with Ø 80 mm air duct.


• MV 81 bVs – model with a protecting insect screen.

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2] Fig. no.
D D1 L L1
MV 80 bV 100 80 5 19 0.0035 1
MV 81 bV 100 80 5 19 0.0035 2

Fig. 1 Fig. 2

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 219


SUPPLY AND EXHAUST
PLASTIC GRILLES

MV 100 bV Application
MV 125 bV • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.

MV 150 bV • Used for correct air flow distribution in premises.


• Wall or ceiling mounting.
Series
Design
• Made of quality and durable plastic.
• Fixing with screws or glue.
• Modifications with air flow regulator and a protecting insect screen are available.

Colour modifications

white brown grey beige mahogany lightwood black

Modifications

MV 100 bV, MV 125 bV, MV 150 bV – round grilles with a flange (bV)

• Fitted with a round connecting flange for mounting to Ø 100 mm (MV 100 bV), Ø 125
mm (MV 125 bV) or Ø 150 mm (MV 150 bV) air ducts.
• MV 100 bVs, MV 125 bVs, MV 150 bVs – models with a protecting insect screen.

MV 100 bVR, MV 125 bVR, MV 150 bVR – models with a round flange and air flow regulator (bVR)

• Fitted with a round connecting flange for mounting to Ø 100 mm (MV 100 bVR), Ø 125
mm (MV 125 bVR) or Ø 150 mm (MV 150 bVR) air ducts.
• Equipped with a movable flap for air flow regulation with a slider.

MV 125 bVRD, MV 150 bVRD – models with air flow regulator and four-element connecting flange (bVRD)

• Equipped with four-element connecting flange with adjustable diameter for connection to
Ø 100-125 mm (MV 125 bVRD) and Ø 100-150 mm (MV 150 bVRD) round air ducts.
• Equipped with a movable flap for air flow regulation with a slider.

Overall dimensions
Dimensions, [mm]
Model Air pass, [m2] Fig. no.
L B D1 D
MV 100 bV 29 118 100 128 0.004 1, 2
MV 100 bVR 29 118 100 128 0.005 1, 3
Fig. 1 Fig. 3
MV 125 bV 29 148 125 160 0.0065 1, 2
MV 125 bVR 29 148 125 160 0.005 1, 3
MV 125 bVRD 45 148 100-125 160 0.005 1, 4
MV 150 bV 29 176 150 200 0.01 1, 2
MV 150 bVR 29 176 150 200 0.005 1, 3
MV 150 bVRD 45 176 100-150 200 0.005 1, 4

Fig. 2 Fig. 4

220 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


PLASTIC HOODS

Outer ventilation hood Application

MVVM 162 • T he outer hood is designed to prevent ingress of water and large objects into the ventilation
equipment from outside.
Mounting from inside •  re-installed with a hood the air duct is mounted in a core hole drilled in the wall. The installation
P
is done from inside.
• S pecial design allows installation of the hood by the operator on a wall of high-rise buildings and
enables airtight sealing of the air duct in the core hole.

Design
• Made of high-quality incombustible ultraviolet resistant plastic.
• Fixation at the end of the air duct with latches.
• The air duct with diameter of 160 mm is made of high-quality PVC plastic.
• T he ventilation hood [1] is equipped with a silicone sealing ring [2] that provides high sealing
integrity of the air duct [3] in the core hole in the wall.

1 2

Mounting
• Drill a core hole with a diameter of 180 mm in the wall.
• Insert the hood into the wall core hole and push it until the sealing ring appears on the outer side.
• Pull the hood in the opposite direction so the silicone sealing ring provides tight seal between the hood and the wall.
• The air duct must be fixed in the wall core hole using mounting foam.

Overall dimensions

L
Model Air pass, [m2]
mm
184
154
160

MVVM 162 -
MVVM 162 03 300
MVVM 162 05 500 0.0078
MVVM 162 07 700
84 L 207 MVVM 162 08 800

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 221


SUPPLY AND EXHAUST
HOODS

MV 102 Application
MV 122 • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.

MV 152 • External wall mounting.

Series Design
• Made of quality and durable plastic.
• Two-element structure for easy maintenance.
• Screw fixing.
• Equipped with a protecting grille against birds and rodents.

Colour modifications

white brown grey beige mahogany lightwood black

Modifications

MV 102, MV 122 – basic modifications

• Supply and exhaust hoods for wall mounting.


• Screw fixing.

MV 102 V, MV 122 V, MV 152 V – models with a round flange

• Supply and exhaust hoods for wall mounting.


• Equipped with a round connecting flange for mounting to Ø 100 mm (MV 102 V), Ø 125
mm (MV 122 V), Ø 150 mm (MV 125 V) air ducts.

MV 102 VU – model with a multi-section flange (VU)

• Supply and exhaust hood for wall mounting.


• Equipped with a connecting flange for mounting to Ø 100, 125 or 55x110 mm air
ducts.

MV 122 VN – model with a flange with various diameters

• Supply and exhaust hood for wall mounting.


• Equipped with a round connecting flange with various diameters for mounting
to Ø 100/110/120/130/150 mm air ducts.

222 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


MV 102 K and MV 122 K – models with a backdraft damper

• Exhaust hoods for wall mounting.


• Fitted with a gravity backdraft damper for back flow prevention.

MV 102 VK, MV 122 VK, MV 152 VK – models with a round flange and a backdraft damper

• Exhaust hoods for wall mounting.


• Fitted with a gravity backdraft damper for back flow prevention.
• Equipped with a round connecting flange for mounting with Ø  100 mm (MV 102 VK),
Ø 125 mm (MV 122 VK), Ø 150 mm (MV 152 VK) air ducts.

MV 102 VUK – model with a multi-section flange (VU)

• Exhaust hood for wall mounting.


• Fitted with a gravity backdraft damper for back flow prevention.
• Equipped with a multi-section flange for mounting with Ø 100, 125 mm or 55x110 mm
air duct.

MV 122 VNK – model with a flange with various diameters (VN)

• Exhaust hood for wall mounting.


• Equipped with a round connecting flange with various diameters for mounting with
Ø 100/110/120/130/150 mm air ducts.
• Fitted with a gravity backdraft damper for back flow prevention.

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2] Fig. no.
 B  H L L1 L2 Flange (D)
MV 102 / MV 102 K 154 110 15 – 87 – 0.008 1
MV 102 V / MV 102 VK 154 110 15 45 87 100 0.008 1, 2
MV 102 VU / MV 102 VUK 154 110 15 39 87 100, 125, 55*110 0.008 1, 3
MV 122 / MV 122 K 186 142 15 – 101 – 0.012 1
MV 122 V / MV 122 VK 186 142 15 45 101 125 0.012 1, 2
MV 122 VN / MV 122 VNK 186 142 15 115 101 100, 110, 120, 130, 150 0.012 1.4
MV 152 V / MV 152 VK 186 142 15 50 101 150 0.012 1.2

Fig. 1 Fig. 2 Fig. 3 Fig. 4

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 223


EXHAUST
PLASTIC GRILLES

MV 100 J Application
Series • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.
• External wall mounting.

Design
• Made of quality and durable plastic.
• Multi-element structure.
• Fitted with louvre shutters for back flow prevention.
• Screw fixing.

Colour modifications

white brown grey beige mahogany lightwood black

Modifications

MV 100 J – basic model with gravity louvre shutters (J)

• Exhaust grille for wall mounting.


• Fitted with louvre shutters for back flow prevention.

MV 100 VJ – model with a round flange and gravity louvre shutters (VJ)

• Exhaust grille for wall mounting.


• Fitted with louvre shutters.
• Fitted with a round connecting flange for connection to Ø 100 mm air duct.

MV 100 VUJ – model with a multi-section flange and gravity louvre shutters (VUJ)

• Exhaust grille for wall mounting.


• Fitted with louvre shutters.
• Equipped with a connecting multi-section flange for connection to Ø 100, 125 mm or
55x110 mm air duct.

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2] Fig. no.
 B H L L1 Flange (D)
MV 100 J 154 110 15 – – 0.0096 1, 2
MV 100 VJ 154 110 15 45 100 0.0075 1, 3
MV 100 VUJ 154 110 15 39 100, 125, 55x110 0.0096 1, 4

Fig. 1 Fig. 2 Fig. 3 Fig. 4

224 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


EXHAUST
PLASTIC GRILLES

MV 120 J Application
MV 150 VJ • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.

Series • External wall mounting.

Design
• Made of quality and durable plastic.
• Multi-element structure.
• Fitted with louvre shutters for back flow prevention.
• Screw fixing.

Colour modifications

white brown grey beige mahogany lightwood black

Modifications

MV 120 J – basic model with gravity louvre shutters (J)

• Exhaust grille for wall mounting.


• Fitted with louvre shutters for back flow prevention.

MV 120 VJ, MV 150 VJ – models with a round flange and louvre shutters (VJ)

• Exhaust grille for wall mounting.


• Fitted with louvre shutters.
• Fitted with a round connecting flange for mounting with Ø 125 mm air duct
(MV 120 J) and 150 mm air duct (MV 150 VJ).

MV 120 VNJ – model with a flange with various diameters and louvre shutters (VNJ)

• Exhaust grille for wall mounting.


• Fitted with louvre shutters.
• Fitted with a round connecting flange for mounting with Ø  100/110/120/130/150 mm
air duct.

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2] Fig. no.
 B H L L1 Flange (D)
MV 120 J 186 142 15 – – 0.016 1, 2
MV 120 VJ 186 142 15 45 125 0.0113 1, 3
MV 120 VNJ 186 142 15 115 100, 110, 120, 130, 150 0.012 1, 4
MV 150 VJ 186 142 15 50 150 0.0113 1.3

Fig. 1 Fig. 2 Fig. 3 Fig. 4

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 225


EXHAUST
PLASTIC GRILLES

MV 160 J Application
Series • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.
• External wall mounting.

Design
• Made of quality and durable plastic.
• Multi-element structure.
• Fitted with louvre shutters for back flow prevention.
• Screw fixing.

Colour modifications

white brown grey beige mahogany lightwood black

Modifications

MV 160 J – basic model with gravity louvre shutters (J)

• Exhaust grille for wall mounting.


• Fitted with louvre shutters for back flow prevention.

MV 160 VJD – model with four-element flange and louvre shutters (VJD)

• Exhaust grille for wall mounting.


• Fitted with louvre shutters.
• Equipped with four-element connecting flange with adjustable diameter for
connection to Ø 100-150 mm round air duct.

Overall dimensions

Overall dimensions, [mm]


Model Air pass, [m2] Fig. no.
B H B1 H1 D L L1
MV 160 J 221 299 205 283 – 15 – 0.034 1, 2
MV 160 VJD 221 299 205 283 100-150 15 42 0.034 1, 3

Fig. 1 Fig. 2 Fig. 3

226 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


EXHAUST
PLASTIC GRILLES

MV 250 J Application
Series • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.
• External wall mounting.

Design
• Made of quality and durable plastic.
• Multi-element structure.
• Fitted with louvre shutters for back flow prevention.
• Screw fixing.

Colour modifications

white brown grey beige mahogany lightwood black

Modifications

MV 250 J – basic model with gravity louvre shutters (J)

• Exhaust grille for wall mounting.


• Fitted with louvre shutters for back flow prevention.

MV 250/150 VJ, MV 250/200 VJ – models with a round flange and louvre shutters

• Fitted with a round connecting flange for mounting with Ø 150 mm (MV 250/150 VJ) or Ø
200 mm (MV 250/200 VJ) air ducts.
• Fitted with louvre shutters for back flow prevention.

MV 250 VJD – model with four-element flange and louvre shutters

• Equipped with four-element connecting flange with adjustable diameter for connection to
Ø 100-150 mm round air duct.
• Fitted with louvre shutters.

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2] Fig. no.
 B  H D L L1
MV 250 J 250 214 – 15 – 0.0177-0.056 1, 2
MV 250 VJD 250 214 100-150 15 41 0.0177-0.056 1, 3
MV 250/150 VJ 250 214 150 15 41 0.0177-0.056 1, 4
MV 250/200 VJ 250 214 200 15 41 0.0177-0.056 1, 5

Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 227


EXHAUST
PLASTIC GRILLES

MV 100 K Application
MV 125 K • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.

Series • External wall mounting.

Design
• Made of quality and durable plastic.
• Designed for mounting with rigid air ducts.
• Extra ventilation grille is provided to arrange natural ventilation in premises with a gas stove.
• Equipped with deviators for back air flow prevention through the bottom ventilation grille.
• Screw fixing.
• The grille has a removable bottom part for easy cleaning.

Colour modifications

white brown grey beige mahogany lightwood black

Modifications

MV 100 K, MV 125 K – basic modifications

• For mounting with rigid Ø 100 mm (MV 100 K) or Ø 125 mm (MV 125 K) air ducts.
• MV 100 Ks, MV 125 Ks – models with a protecting insect screen.

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2]
B H B2 H2 D L L1
MV 100 K 182 252 160 226 100 10 45 0.0039
MV 125 K 182 252 160 226 125 10 45 0.0039

228 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


EXHAUST
PLASTIC GRILLES

MV 100 KV Application
MV 120 KV • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.

MV 125 KV • Wall mounting.

Series Design
• Made of quality and durable plastic.
• Suitable for mounting with flexible air ducts.
• Equipped with deviators for back air flow prevention through the bottom ventilation grille.
• Extra ventilation grille is provided to arrange natural ventilation in premises with a gas stove.
• Screw fixing.
• The grille has a removable bottom part for easy cleaning.

Colour modifications

white brown grey beige mahogany lightwood black

Modifications

MV 100 KV, MV 120 KV, MV 125 KV – models with a round flange (KV)

• Equipped with a round flange for connection to Ø 100 mm (MV 100 KV), Ø 120 mm
(MV 120 KV), Ø 125 mm (MV 125 KV) air ducts.
• MV 100 KVs, MV 120 KVs, MV 125 Ks – models with a protecting insect screen.

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2]
B H B1 H1 D L1 L
MV 100 KV 182 252 160 226 100 75 10 0.0039
MV 120 KV 182 252 160 226 120 75 10 0.0039
MV 125 KV 182 252 160 226 125 75 10 0.0039

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 229


ASA PLASTIC
VENTILATION GRILLES

 External ventilation grilles made of weather-resistant ASA plastic.

ASA (Acrylonitrile Styrene Acrylate) plastic is a 3-D polystyrene-copolymer with butadiene rubber, an updated version
of ABS plastic.
Due to the specially selected balance of mechanical and physical features the material is the ideal option for external
plastic products. ASA plastic is UV- and weather-resistant, durable and long-lasting.
ASA und ABS polymers have a similar chemical structure. Acrylonitrile and styrene ensure water resistance, elasticity and
hardness. Butadiene rubber adds higher density for ASA plastic and improves its chemical composition. The products made
of ASA plastic have numerous benefits:
 
 high UV-resistance (due to single covalent bonds ASA plastic is less prone to oxidation and UV exposure)


 
 h
igh temperature resistance (thermal deformation temperature is +91 °C)

 
 excellent flexibility and high ultimate resistance (changing of plasticity index does not exceed 2 %)


 
 fire resistance


 
 w
eather resistance (no loss of mechanical properties and deterioration of exterior caused by negative weather impact)

 ASA plastic application

ASA polymers are used in ventilation and car industry (xenon headlamps, car spoilers, radiator grilles, bodies for rear-
view mirror). Owing to high performance features of ASA plastic it is used for manufacture of window profiles, plastic roofs,
external ventilation parts.
Therefore you can shop ASA plastic ventilation grilles by VENTS with entire confidence that they will reliably serve
and retain their visual appeal for years to come. The external grilles are available in white, brown and beige colour
modifications.

230 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


 Benefits of ASA plastic products

Reliability.
ASA High mechanical toughness Long-term retention
UV STABIL and UV-resistance. of basic characteristics.
UV-resistant High light resistant Temperature resistant Морозостойкие Chemical
Ch i l resistant
i t t Reliableresistant
Impact

Heat-ageing resistance. The colours remain Resistant to sulphuric acid, alkali,


ASA ASA
bright ammonia, diesel fuel and engine oil,
STABIL UV STABIL and clear even after many years of
weather exposure. ethanol and ethylene glycol.
esistant High light resistant UV-resistant High light
Temperature resistant resistant
Морозостойкие Temperaturei resistant
Chemical
Ch i t t Морозостойкие
l resistant Impact resistant Chemical
Ch i l resistant
i t t Impact resistant

High heat and frost resistance means no


ASA deformation and no cracks during outer Improved impact resistance.
UV STABIL
temperature and humidity drops.
ht resistant UV-resistant
Temperature resistant High Морозостойкие
light resistant Temperature
i resistant
Chemical
Ch l resistant
i t t Морозостойкие
Impact resistant Chemical
Ch i l resistant
i t t Impact resistant

 Contents

Supply and exhaust grilles Supply and exhaust ventilation hoods


page page

MV 100 V ASA series 232 MV 102 V ASA, MV 122 V ASA, 237


MV 152 V ASA series

page
Exhaust grilles
MV 120 V ASA series 233
page

MV 100 J ASA series 238


page

MV 150 V ASA series 234


page

MV 120 J ASA, 239


page MV 150 VJ ASA series
MV 250 ASA series 235
page

MV 250 J ASA series 240


Round supply and exhaust grilles
page

MV 100 bV ASA, MV 125 bV ASA, 236


MV 150 bV ASA series

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 231


SUPPLY AND EXHAUST
PLASTIC GRILLES

MV 100 V ASA Application


Series • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.
• Used for correct air flow distribution in premises.
• Wall or ceiling mounting.

Design
• Made of quality and durable plastic.
• Multi-element structure. The internal part is fixed to the base with latches for easy cleaning without
dismantling.
• Screw fixing.
• The grille has slanted vanes.

Colour modifications

white brown beige


Modifications

MV 100 V ASA – model with a round flange (V)

• Fitted with a round connecting flange for mounting with Ø 100 mm air duct.
• Suitable for direct mounting with VENTS VKO 100 fan.
• MV 100 Vs ASA – model with a round flange and a protecting insect screen.

MV 100 VU ASA – model with a multi-section flange (VU)

• Equipped with a multi-section connecting flange for mounting with Ø100, 125 mm
or 55x110 mm air duct.
• MV 100 VUs ASA – model with a multi-section flange and a protecting insect
screen.

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2] Fig. no.
B  H L L1 Flange (D)

MV 100 V ASA 154 110 15 45 100 0.004 1, 2


MV 100 VU ASA 154 110 15 39 100, 125, 55x110 0.0067 1, 3

Fig. 1 Fig. 2 Fig. 3

232 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


MV 120 V ASA Application
Series • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.
• Used for correct air flow distribution in premises.
• Wall or ceiling mounting.

Design
• Made of quality and durable plastic.
• Multi-element structure. The internal part is fixed to the base with latches for easy cleaning without
dismantling.
• Screw fixing.
• The grille has slanted vanes.

Colour modifications

white brown beige

Modifications

MV 120 V ASA – model with a round flange (V)

• Fitted with a round connecting flange for mounting with Ø 125 mm air duct.
• Suitable for direct mounting with VENTS VKO 125 fan.
• MV 120 Vs ASA – model with a round flange and a protecting insect screen.

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2] Fig. no.
B  H L L1 Flange (D)

MV 120 V ASA 186 142 15 45 125 0.0083 1, 2

Fig. 1 Fig. 2

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 233


SUPPLY AND EXHAUST
PLASTIC GRILLES

MV 150 V ASA Application


Series • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.
• Used for correct air flow distribution in premises.
• Wall or ceiling mounting.

Design
• Made of quality and durable plastic.
• Multi-element structure. The internal part is fixed to the base with latches for easy cleaning without
dismantling.
• Screw fixing.
• The grille has slanted vanes.

Colour modifications

white brown beige

Modifications

MV 150 V ASA – model with a round flange (V)

• Fitted with a round connecting flange for mounting with Ø 150 mm air duct.
• Suitable for direct mounting with VENTS VKO 150 fan.
• MV 150 Vs ASA – model with a round flange and a protecting insect screen.

Overall dimensions

Dimensions, [mm]
Model Flange Air pass, [m2] Fig. no.
B  H L L1
(D)

MV 150 V ASA 186 142 15 50 150 0.0083 1, 2

Fig. 1 Fig. 2

234 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


MV 250 ASA Application
Series • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.
• Used for correct air flow distribution in premises.
• Wall or ceiling mounting.

Design
• Made of quality and durable plastic.
• Multi-element structure. The internal part is fixed to the base with latches for easy cleaning without
dismantling.
• Fixing with screws or lugs depending on grille modification.

Colour modifications

white brown beige


Modifications

MV 250/150 V ASA – model with a round Ø 150 mm flange

• Wall or ceiling mounting.


• Fitted with a round connecting flange for mounting with Ø 150 mm air duct.
• Suitable for direct mounting with VENTS VKO 150 fan.
• Screw fixing.
• MV 250/150 Vs ASA – model with a round flange and a protecting insect screen.

MV 250/200 V ASA – model with a round Ø 200 mm flange

• OFitted with a round connecting flange for mounting with Ø 200 mm air duct.
• Screw fixing.
• MV 250/200 Vs ASA – model with a round flange and a protecting insect screen.

MV 250 VD ASA – model with four-element connecting flange

• Equipped with four-element connecting flange with adjustable diameter for connection to Ø
100-150 mm round air duct.
• Screw fixing.
• MV 250 VDs ASA – model with four-element flange and a protecting insect screen.

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2] Fig. no.
B  H L L1 Flange (D)
MV 250/150 V ASA 250 214 14 44 150 0.02 1, 2
MV 250/200 V ASA 250 214 14 44 200 0.02 1, 2
MV 250 VD ASA 250 214 14 42 100-150 0.02 1, 3

Fig. 1 Fig. 2 Fig. 3

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 235


SUPPLY AND EXHAUST
PLASTIC GRILLES

MV 100 bV ASA Application


MV 125 bV ASA • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.

MV 150 bV ASA • Used for correct air flow distribution in premises.


• Wall or ceiling mounting.
Series
Design
• Made of quality and durable plastic.
• Fixing with screws or glue.
• Modifications with air flow regulator and a protecting insect screen are available.

Colour modifications

white brown beige

Modifications

MV 100 bV ASA, MV 125 bV ASA, MV 150 bV ASA – round grilles with a flange (bV)

• Fitted with a round connecting flange for mounting to Ø 100 mm (MV 100 bV ASA),
Ø 125 mm (MV 125 bV ASA) or Ø 150 mm (MV 150 bV ASA) air ducts.
• MV 100 bVs ASA, MV 125 bVs ASA, MV 150 bVs ASA – models with a protecting insect
screen.

MV 100 bVR ASA – models with a round flange and air flow regulator (bVR)

• Fitted with a round connecting flange for mounting to Ø 100 mm.


• Equipped with a movable flap for air flow regulation with a slider.
• MV 100 bVRs ASA – with a protecting insect screen.

MV 125 bVRD ASA, MV 150 bVRD ASA – models with air flow regulator and four-element connecting flange (bVRD)

• Equipped with four-element connecting flange with adjustable diameter for connection to
Ø 100-125 mm (MV 125 bVRD ASA) and Ø 100-150 mm (MV 150 bVRD ASA) round air ducts.
• Equipped with a movable flap for air flow regulation with a slider.

Overall dimensions
Dimensions, [mm]
Model Air pass, [m2] Fig. no.
L B D1 D
MV 100 bV ASA 29 118 100 128 0.004 1, 2
MV 100 bVR ASA 29 118 100 128 0.005 1, 3
Fig. 1 Fig. 3
MV 125 bV ASA 29 148 125 160 0.0065 1, 2
MV 125 bVRD ASA 45 148 100-125 160 0.005 1, 4
MV 150 bV ASA 29 176 150 200 0.01 1, 2
MV 150 bVRD ASA 45 176 100-150 200 0.005 1, 4

Fig. 2 Fig. 4

236 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


SUPPLY AND EXHAUST
HOODS

MV 102 V ASA Application


MV 122 V ASA • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.

MV 152 V ASA • External wall mounting.

Series Design
• Made of quality and durable plastic.
• Two-element structure for easy maintenance.
• Screw fixing.
• Equipped with a protecting grille against birds and rodents.

Colour modifications

white brown beige

Modifications

MV 102 VK ASA, MV 122 VK ASA, MV 152 VK ASA – models with a round flange and a backdraft damper

• Exhaust hoods for wall mounting.


• Fitted with a gravity backdraft damper for back flow prevention.
• Equipped with a round connecting flange for mounting with Ø  100 mm (MV 102 VK ASA),
Ø 125 mm (MV 122 VK ASA), Ø 150 mm (MV 152 VK ASA) air ducts.

MV 102 VUK ASA – model with a multi-section flange (VU)

• Exhaust hood for wall mounting.


• Fitted with a gravity backdraft damper for back flow prevention.
• Equipped with a multi-section flange for mounting with Ø 100, 125 mm or 55x110 mm
air duct.

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2] Fig. no.
 B H L L1 L2 Flange (D)
MV 102 VK ASA 154 110 15 45 87 100 0.008 1, 2
MV 102 VUK ASA 154 110 15 39 87 100, 125, 55*110 0.008 1, 3
MV 122 VK ASA 186 142 15 45 101 125 0.012 1, 2
MV 152 VK ASA 186 142 15 50 101 150 0.012 1.2

Fig. 1 Fig. 2 Fig. 3

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 237


EXHAUST
PLASTIC GRILLES

MV 100 J ASA Application


Series • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.
• External wall mounting.

Design
• Made of quality and durable plastic.
• Multi-element structure.
• Fitted with louvre shutters for back flow prevention.
• Screw fixing.

Colour modifications

white brown beige

Modifications

MV 100 VJ ASA – model with a round flange and gravity louvre shutters (VJ)

• Exhaust grille for wall mounting.


• Fitted with louvre shutters.
• Fitted with a round connecting flange for connection to Ø 100 mm air duct.

MV 100 VUJ ASA – model with a multi-section flange and gravity louvre shutters (VUJ)

• Exhaust grille for wall mounting.


• Fitted with louvre shutters.
• Equipped with a connecting multi-section flange for connection to Ø 100, 125 mm or
55x110 mm air duct.

Overall dimensions
Dimensions, [mm]
Model Air pass, [m2] Fig. no.
 B  H L L1 Flange (D)
MV 100 VJ ASA 154 110 15 45 100 0.0075 1, 2
MV 100 VUJ ASA 154 110 15 39 100, 125, 55x110 0.0096 1, 3

Fig. 1 Fig. 2 Fig. 3

238 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


MV 120 VJ ASA Application
MV 150 VJ ASA • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.

Series • External wall mounting.

Design
• Made of quality and durable plastic.
• Multi-element structure.
• Fitted with louvre shutters for back flow prevention.
• Screw fixing.

Colour modifications

white brown beige

Modifications

MV 120 VJ ASA, MV 150 VJ ASA – models with a round flange and louvre shutters (VJ)

• Exhaust grille for wall mounting.


• Fitted with louvre shutters.
• Fitted with a round connecting flange for mounting with Ø 125 mm air duct
(MV 120 VJ ASA) and 150 mm air duct (MV 150 VJ ASA).

Overall dimensions
Dimensions, [mm]
Model Air pass, [m2] Fig. no.
 B  H L L1 Flange (D)

MV 120 VJ ASA 186 142 15 45 125 0.0113 1, 2


MV 150 VJ ASA 186 142 15 50 150 0.0113 1, 2

Fig. 1 Fig. 2

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 239


SUPPLY AND EXHAUST
PLASTIC GRILLES

MV 250 J ASA Application


Series • Decoration of supply and exhaust vents of public, residential and industrial ventilation systems.
• External wall mounting.

Design
• Made of quality and durable plastic.
• Multi-element structure.
• Fitted with louvre shutters for back flow prevention.
• Screw fixing.

Colour modifications

white brown beige

Modifications

MV 250/150 VJ ASA, MV 250/200 VJ ASA – models with a round flange and louvre shutters

• Fitted with a round connecting flange for mounting with Ø 150 mm


(MV 250/150 VJ ASA) or Ø 200 mm (MV 250/200 VJ ASA) air ducts.
• Fitted with louvre shutters for back flow prevention.

MV 250 VJD ASA – model with four-element flange and louvre shutters

• Equipped with four-element connecting flange with adjustable diameter for connection to
Ø 100-150 mm round air duct.
• Fitted with louvre shutters.

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2] Fig. no.
B H D L L1
MV 250 VJD ASA 250 214 100-150 15 41 0.0177-0.056 1, 2
MV 250/150 VJ ASA 250 214 150 15 41 0.0177-0.056 1, 3
MV 250/200 VJ ASA 250 214 200 15 41 0.0177-0.056 1, 4

Fig. 1 Fig. 2 Fig. 3 Fig. 4

240 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


VENTS. Domestic ventilation. Catalogue №6 | 02-2020 241
DOOR
PLASTIC GRILLES

242 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Supply and exhaust
door grille page

MV 350 Series 244

Supply and exhaust


door grille page

MV 350/2 Series 245

Supply and exhaust


door grille page

MV 450 Series 246

Supply and exhaust


door grille page

MV 450/2 Series 247

Supply and exhaust


door grille page

MV 380 Series 248

Supply and exhaust


door grille page

MV 380/2 Series 249

Supply and exhaust


door grille page

MV 430/2 Series 250

Supply and exhaust


door grille page

MV 440/2 Series 251

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 243


SUPPLY AND EXHAUST
DOOR GRILLES

MV 350 Application
Series • Mounting in door leaves of bathrooms, kitchens, etc.
• Suitable for installation into window sills for correct warm air distribution from radiators.
• Used to arrange correct air circulation in premises.

Design
• Made of high quality plastic.
• Available in various colour modifications.
• Fixing with screws directly to a door leaf or to window sills.
• Modifications with a protecting insect screen or a movable flap for air flow regulation are
available.

Colour modifications

white brown grey beige mahogany lightwood black

Modifications

MV 350 – basic modification

• Mounting in door leaves of bathrooms, kitchens, etc.


• Minimum door leaf thickness is 32 mm.
• Required cutout area in door leaf is 95x334 mm.
• MV 350 s – model with a protecting insect screen.

MV 350 R – model with an air flow regulator (R)

• Mounting in door leaves of bathrooms, kitchens, etc.


• Minimum door leaf thickness is 32 mm.
• Required cutout area in door leaf for MV 350 R model is 95x334 mm.
• MV 350 Rs – model with a movable flap for air flow regulation and a protecting insect screen.

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2]
H L
MV 350 130 368 0.014
MV 350 R 130 368 0.0095

244 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


SUPPLY AND EXHAUST
DOOR GRILLES

MV 350/2 Application
Series • Mounting in door leaves of bathrooms, kitchens, etc.
• Used to arrange correct air circulation in premises.

Design
• The grille consists of two parts.
• Made of high quality plastic.
• Available in various colour modifications.
• Fixing with screws directly to a door leaf.
• Modifications with a protecting insect screen or a movable flap for air flow regulation
are available.

Colour modifications

white brown grey beige mahogany lightwood black

MV 350/2 – basic modification

• Mounting in door leaves of bathrooms, kitchens, etc.


• Minimum door leaf thickness is 32 mm.
• Required cutout area in door leaf for MV 350/2 model is 95x334 mm.
• MV 350/2s – model with a protecting insect screen.

MV 350 R/2 – model with an air flow regulator (R)

• Mounting in door leaves of bathrooms, kitchens, etc.


• Minimum door leaf thickness is 32 mm.
• Required cutout area in door leaf for MV 350 R/2 model is 95x334 mm.
• MV 350 R/2s – model with a protecting insect screen.

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2]
H L
MV 350/2 130 368 0.014
MV 350 R/2 130 368 0.0065

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 245


SUPPLY AND EXHAUST
DOOR GRILLES

MV 450 Application
Series • Mounting in door leaves of bathrooms, kitchens, etc.
• Suitable for installation into window sills for correct warm air distribution from radiators.
• Used to arrange correct air circulation in premises.

Design
• Made of high quality plastic.
• Available in various colour modifications.
• Fixing with screws directly to a door leaf or to window sills .
• Modifications with a protecting insect screen or a movable flap for air flow regulation are
available.

Colour modifications

white brown grey beige mahogany lightwood black


Modifications

MV 450 – basic modification

• Mounting in door leaves of bathrooms, kitchens, etc.


• Minimum door leaf thickness is 32 mm.
• Required cutout area in door leaf for MV 450 model is 95x432 mm.
• MV 450 s – model with a protecting insect screen.

MV 450 R – model with air flow regulator (R)

• Mounting in door leaves of bathrooms, kitchens, etc.


• Minimum door leaf thickness is 32 mm.
• Required cutout area in door leaf for MV 450 R model is 95x432 mm.
• MV 450 Rs – model with a movable flap and a protecting insect screen.

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2]
H L

MV 450 124 462 0.019


MV 450 R 124 462 0.015

246 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


SUPPLY AND EXHAUST
DOOR GRILLES

MV 450/2 Application
Series • Mounting in door leaves of bathrooms, kitchens, etc.
• Used to arrange correct air circulation in premises.

Design
• The grille consists of two parts.
• Made of high quality plastic.
• Available in various colour modifications.
• Fixing with screws directly to a door leaf.
• Modifications with an insect screen or a movable flap for air flow regulation are
available.

Colour modifications

white brown grey beige mahogany lightwood black

Modifications

MV 450/2 – double grille models

• Mounting in door leaves of bathrooms, kitchens, etc.


• Minimum door leaf thickness is 32 mm.
• Required cutout area in door leaf for MV 420/2 model is 95x432 mm.
• MV 450/2s – model with a protecting insect screen.

MV 450 R/2 – double models with air flow regulator (R)

• Mounting in door leaves of bathrooms, kitchens, etc.


• Minimum door leaf thickness is 32 mm.
• Required cutout area in door leaf for MV 450 R/2 model is 95x432 mm.
• MV 450 R/2s – models with a protecting insect screen.

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2]
H L

MV 450/2 124 462 0.019


MV 450 R/2 124 462 0.015

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 247


SUPPLY AND EXHAUST
DOOR GRILLES

MV 380 Application
Series • Mounting in door leaves of bathrooms, kitchens, etc.
• Suitable for installation into window sills for correct warm air distribution from radiators.
• Used to arrange correct air circulation in premises.

Design
• Made of high quality plastic.
• Available in various colour modifications.
• Fixing with screws directly to a door leaf or to window sills.
• Modifications with a protecting insect screen or a movable flap for air flow regulation are
available.

Colour modifications

white brown grey beige mahogany lightwood black

Modifications

• MV 380 s – model with a protecting insect screen.

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2]
H L

MV 380 104 382 0.0078

248 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


SUPPLY AND EXHAUST
DOOR GRILLES

MV 380/2 Application
Series • Mounting in door leaves of bathrooms, kitchens, etc.
• Used to arrange correct air circulation in premises.

Design
• Two-section grille.
• Made of high quality plastic.
• Available in various colour modifications.
• The mating grille parts are connected by slots and fixed with screws.
• Minimum door leaf thickness is 29 mm.
• Required cutout area in door leaf is 86x358 mm.
• Modifications with a protecting insect screen are available.

Colour modifications

white brown grey beige mahogany lightwood black

Modifications

• MV 380/2 s – model with a protecting insect screen.

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2]
H L

MV 380/2 104 382 0.0078

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 249


SUPPLY AND EXHAUST
DOOR GRILLES

MV 430/2 Application
Series • Mounting in door leaves of bathrooms, kitchens, etc.
• Used to arrange correct air circulation in premises.

Design
• The grille consists of two parts.
• Made of high quality plastic.
• Available in various colour modifications.
• The mating grille parts are connected by slots and fixed with screws.
• Required cutout area in door leaf for is 80x434 mm.
• Minimum door leaf thickness is 30 mm.
• Modifications with a protecting insect screen are available.

Colour modifications

white brown grey beige mahogany lightwood black

Modifications

• MV 430/2 s – model with a protecting insect screen.

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2]
H L

MV 430/2 91 453 0.0152

250 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


SUPPLY AND EXHAUST
DOOR GRILLES

MV 440/2 Application
Series • Mounting in door leaves of bathrooms, kitchens, etc.
• Used to arrange correct air circulation in premises.

Design
• The grille consists of two parts.
• Made of high quality white plastic.
• Available in various colour modifications.
• The mating grille parts are connected by slots and fixed with screws.
• Minimum door leaf thickness is 32 mm.
• Required cutout area in door leaf is 99x435 mm.
• Modifications with a protecting insect screen are available.

Colour modifications

white brown grey beige mahogany lightwood black

Modifications

• MV 440/2 s – model with a protecting insect screen.

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2]
H L

MV 440/2 120 460 0.0152

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 251


SUPPLY AND EXHAUST
AIR DISK VALVES

252 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Supply and exhaust plastic air disk valves page
A…VR Series 254

Supply and exhaust plastic air disk valves page


A…VRF Series 256

Supply plastic air disk valves page


A…PR Series 258

Supply plastic air disk valves page


A…PRF Series 260

Supply metal air disk valves page


AM…PRF Series 262

Supply and exhaust metal air disk valves page


AM…VRF Series 264

Supply and exhaust metal air disk valves page


AM...VRF N Series 266

Supply and exhaust plastic diffusers page


MV…PF Series 267

Supply and exhaust


plastic diffusers with light page
FL 100 Series 268

Supply and exhaust


plastic diffusers with light page
FL-2 100 Series 270

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 253


SUPPLY AND EXHAUST
PLASTIC AIR DISK VALVES

A…VR Application
Series • For supply and exhaust ventilation, air conditioning and heating.
• Mounting in false ceilings or walls.
• Used to arrange correct air circulation in premises.

Design
• Made of high quality plastic (ABS plastic or polystyrene).
• Special aerodynamic disk valve design ensures uniform air distribution.
• Smooth air pass regulation due to rotation of central part of the damper.
• Easy mounting with fixing lugs.
• The internal part has a sealing ring for more tight fit.

Grille modifications

A 80 VR, A 100 VR, A 125 VR, A 150 VR, A 200 R – basic modifications

• Equipped with fixing lugs for easy connection to


Ø 80/100/125/150/200 mm round air ducts.
• Modification may include F 80 – F 200 flange (available upon
separate order).

A 200 VR – two-element model

• Equipped with fixing lugs for easy connection to Ø 200 mm


round air ducts.
• Two regulating elements for more perfect air flow
distribution.
• Modification may include F 200 flange (available upon
separate order).

Overall dimensions

Dimensions, [mm]
Model Damper normal Air pass, [m2] Fig. no.
D D1 D2 D3 H max H1 H2
pitch, mm
A 80 VR 80 64 90 132 50 34 16 0...8 0...0.002 1
A 100 VR 100 84 90 148 65 44 26 0...20 0...0.006 1
A 125 VR 125 105 110 166 70 40 20 0...22 0...0.008 1
A 150 VR 150 125 128 200 80 50 30 0...23 0...0.009 1
A 200 R 200 177.6 183 246 80 53 33 0...16 0...0.009 1
A 200 VR 200 177.6 128 246 80 53 33 0...19 0.001...0.008 2

Fig. 1 Fig. 2

254 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Technical parameters

The internal part of the air disk valve is pulled out to ensure the required clearance S (mm) (fig. 3) to provide required
air flow according to the diagram.

Fig. 3

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 255


SUPPLY AND EXHAUST
PLASTIC AIR DISK VALVES

A…VRF Application
Series • For supply and exhaust ventilation, air conditioning and heating.
• Mounting in false ceilings or walls.
• Used to arrange correct air circulation in premises.

Design
• Made of high quality plastic (ABS plastic or polystyrene).
• Special aerodynamic disk valve design ensures uniform air distribution.
• Smooth air pass regulation due to rotation of central part of the damper.
• Easy installation with fixing lugs and a mounting flange with a lock ring.
• The internal part has a sealing ring for more tight fit.

Grille modifications

A 80 VRF, A 100 VRF, A 125 VRF, A 150 VRF, A 200 RF – models with a mounting flange

• Equipped with a mounting flange and a lock ring for easy


connection to round Ø 80/100/125 /150/200 mm air ducts.
• Mounting flange is fixed to false ceiling with screws.
• Lock ring provides easy fixing of the flexible air duct on a
mounting flange.

A 200 VRF – double model with Ø 200 mm mounting flange

• Two regulating elements for more perfect air flow


distribution.
• Equipped with a mounting flange and a lock ring for easy
connection to round Ø 200 mm air ducts.
• Mounting flange is fixed to false ceiling with screws.
• Lock ring provides easy fixing of the flexible air duct on a
mounting flange.

A 200/150 VRF – two-element model with a mounting flange

• Two regulating elements for more perfect air flow


distribution.
• Equipped with a mounting reducing flange and a lock ring
for easy connection to round Ø 150 mm air ducts.
• Mounting flange is fixed to false ceiling with screws.
• Lock ring provides easy fixing of the flexible air duct on a
mounting flange.

256 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Overall dimensions

Dimensions, [mm]
Damper normal
Model Air pass, [m2] Fig. no.
D D1 D2 H H1 pitch, mm

A 80 VRF 80 90 132 58 18 0...0.002 0...8 1


A 100 VRF 100 90 148 58 28 0...0.006 0...20 1
A 125 VRF 125 110 166 58 20 0...0.008 0...22 1
A 150 VRF 150 128 200 58 20 0...0.009 0...23 1
A 200 RF 200 183 246 58 20 0...0.009 0...16 1
A 200 VRF 200 128 246 58 20 0.001...0.008 0...19 2 Fig. 4
A 200/150 VRF 150 128 246 82 20 0.001...0.008 0...19 3

Fig. 1 Fig. 2 Fig. 3

Technical parameters

The internal part of the air disk valve is pulled out to ensure the required clearance S mm (fig. 4) to provide required air flow according to the diagram.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 257


SUPPLY
PLASTIC AIR DISK VALVES

A…PR Application
Series • For supply ventilation, air conditioning and heating.
• Designed for wall mounting or installation into false ceiling.
• Used to arrange correct air supply and circulation in premises.

Design
• Made of high quality plastic (ABS plastic or polystyrene).
• Special aerodynamic disk valve design ensures uniform air distribution.
• Smooth air pass regulation due to rotation of central part of the damper.
• Easy mounting with fixing lugs.
• The internal part has a sealing ring for more tight fit.

Grille modifications

A 150 PR – basic modification

• Equipped with fixing lugs for easy connection with Ø 150 mm


round air ducts.
• Modification may include F 150 flange (available upon
separate order).

A 200 PR – two-element models

• Equipped with fixing lugs for easy connection with


Ø 200 mm round air ducts.
• Two regulating elements for more perfect air flow
distribution.
• Modification may include F 200 flange (available upon
separate order).

258 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Technical parameters

Air flow [m3/h] Air flow [m3/h]

The internal part of the air disk valve is pulled out to ensure the required clearance S (mm) to provide required air flow according to the diagram.

Overall dimensions

Dimensions, [mm]
Damper normal
Model Air pass, [m2] Fig. no.
D D1 D2 D3 H max H1 H2 pitch, [mm]

A 150 PR 150 125 155 200 80.5 50 30 0...0.011 0...21 1


A 200 PR 200 177.6 155 246 80.5 53 33 0...0.012 0...21 2

Fig. 1 Fig. 2

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 259


SUPPLY
PLASTIC AIR DISK VALVES

A…PRF Application
Series • For supply ventilation, air conditioning and heating.
• Designed for wall mounting or installation into false ceiling.
• Used to arrange correct air supply and circulation in premises.

Design
• Made of high quality plastic (ABS plastic or polystyrene).
• Special aerodynamic disk valve design ensures uniform air distribution.
• Smooth air pass regulation due to rotation of central part of the damper.
• Easy mounting with fixing lugs.
• The internal part has a sealing ring for more tight fit.

Grille modifications

A 150 PRF – models with a mounting flange

• Equipped with a mounting flange and a lock ring for easy


connection to round Ø 150 mm air ducts.
• Mounting flange is fixed to false ceiling with screws.
• Lock ring provides easy fixing of the flexible air duct on a
mounting flange.

A 200 PRF – models with a mounting flange

• Equipped with a mounting flange and lock ring for easy


connection to round Ø 200 mm air ducts.
• Two regulating elements for more perfect air flow
distribution.
• Mounting flange is fixed to false ceiling with screws.
• Lock ring provides easy fixing of the flexible air duct on a
mounting flange.

260 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Technical parameters

Air flow [m3/h] Air flow [m3/h]

The internal part of the air disk valve is pulled out to ensure the required clearance S (mm) to provide required air flow according to the diagram.

Overall dimensions

Dimensions, [mm]
Damper normal
Model Air pass, [m2] Fig. no.
D D1 D2 H max H1 H2 pitch, [mm]

A 150 PRF 150 155 200 80.5 78 58 0...21 0...0.011 1


A 200 PRF 200 155 246 80.5 78 58 0...22 0...0.012 2

Fig. 1 Fig. 2

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 261


SUPPLY METAL AIR DISK VALVES

AM…PRF Application
Series • For supply ventilation, air conditioning and heating.
• Designed for wall mounting or installation into false ceiling.
• Used to arrange correct air supply circulation in premises.

Design
• Made of polymer-coated steel.
• Special aerodynamic disk valve design ensures uniform air distribution.
• Smooth air pass regulation due to rotation of central part of the damper.
• Equipped with a mounting flange for easy connection to round Ø 100-200 mm air ducts.
• Mounting flange is fixed to false ceiling with screws.
• The internal part has a sealing ring for more tight fit.

Overall dimensions

Dimensions [mm]
Model
D D1 D2 D3

AM 100 PRF 99 125 88 138


AM 125 PRF 124 150 112 167
AM 150 PRF 149 175 144 199
AM 200 PRF 199 225 200 249

262 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Technical parameters

AM 100 PRF AM 125 PRF

Air flow [m3/h] Air flow [m3/h]

AM 150 PRF AM 200 PRF

Air flow [m3/h] Air flow [m3/h]

The internal part of the air disk valve is pulled out to ensure the required clearance S (mm) to provide required air flow according to
the diagram.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 263


SUPPLY AND EXHAUST
METAL AIR DISK VALVES

AM…VRF Application
Series • For supply and exhaust ventilation, air conditioning and heating.
• Mounting in false ceilings or walls.
• Used to arrange correct air circulation in premises.

Design
• Made of polymer-coated steel.
• Special aerodynamic disk valve design ensures uniform air distribution.
• Smooth air pass regulation due to rotation of central part of the damper.
• Equipped with a mounting flange for easy connection to round Ø 100-200 mm air ducts.
• Mounting flange is fixed to false ceiling with screws.
• The internal part has a sealing ring for more tight fit.

Overall dimensions

Dimensions [mm]
Model
D D1 D2 D3

AM 100 VRF 99 123 75 128


AM 125 VRF 124 152 100 154
AM 150 VRF 149 173 128 184
AM 200 VRF 199 225 178 235

264 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Technical parameters

Air flow [m3/h] Air flow [m3/h]

Air flow [m3/h] Air flow [m3/h]

The internal part of the air disk valve is pulled out to ensure the required clearance S (mm) to provide required air flow according to the
diagram.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 265


SUPPLY AND EXHAUST
METAL AIR DISK VALVES

AM...VRF N Application
Series • For supply and exhaust ventilation, air conditioning and heating.
• Mounting in false ceilings or walls.
• Used to arrange correct air circulation in premises.

Design
• Made of stainless steel.
• Special aerodynamic shape enables uniform air distribution.
• Smooth air flow control due to the central valve rotation.
• Equipped with a round Ø 100, 125 or 150 mm spigot for connection to air ducts.
• Easy mounting with fixing lugs or screws.

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2]
D D1 L
AM 100 VRF N 97 118 52 0.0032
AM 125 VRF N 120 141 52 0.0057
AM 150 VRF N 145 162 62 0.0090
AM 200 VRF N 195 214 73 0.0132

266 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


SUPPLY AND EXHAUST
PLASTIC DIFFUSERS

MV…PF Application
Series • For supply ventilation, air conditioning and heating.
• Designed for wall mounting or installation into false ceiling.
• Used to arrange correct air circulation in premises.

Design
• Made of high quality plastic (ABS plastic or polystyrene).
• Special aerodynamic disk valve design ensures uniform air distribution.
• Easy mounting with a mounting flange and a lock ring.
• The internal part has a sealing ring for more tight fit.
• Models with a built-in insect screen.

Diffuser modifications

MV 80 PF – MV 315 PF – basic modifications

• Equipped with mounting flanges with a lock ring for easy


connection to round Ø 80-315 mm air ducts.
• MV 80 PFs – MV 315 PFs – models with a protecting insect
screen.

MV 200/150 PF – model with Ø 150 mm reducing flange

• MV 200/150 PF – model equipped with a reducing flange for


connection to Ø 150 mm air duct.
• MV 200/150 PFs – model with a protecting insect screen.

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2]
D D1 H H1

MV 80 PF 80 123 70 12.5 0.004


MV 100 PF 100 141 71 12.5 0.006
MV 125 PF 125 166 72 14 0.010
MV 150 PF 150 188 72 15 0.014
MV 200 PF 200 240 72 14.5 0.025
MV 200/150 PF 150 240 99 14.5 0.025
MV 250 PF 250 294 78 20.5 0.039
MV 315 PF 315 371 82.5 25 0.062

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 267


SUPPLY AND EXHAUST
PLASTIC DIFFUSERS WITH LIGHT

FL 100 Application
Series • For supply and exhaust ventilation and air conditioning systems.
• For synchronous ventilation and backlighting of premises.
• Designed for a wall or suspended ceiling mounting.
• T he best solution for use in exhaust systems of premises with high humidity, such as bathrooms and
WCs, due to safe voltage 12 V.

Design
• Made of high quality plastic.
• T he diffuser is supplied with a LED lamp with power demand from 1 to 7 W and light temperature
from 3000 K (white warm) to 7000 K (white cold).
• Special aerodynamic shape ensures uniform air distribution.
• Easy mounting with a mounting flange and screws.
• External removable grille for technical maintenance and cleaning.
• Removable front panels are available in 3 colours: white, chrome and gold.
• IP rating is IPX4.

Colour modifications

white chrome gold


FL 100 LED FL 100 LED chrome FL 100 LED gold

Diffuser modifications

A model with a LED lamp 12 V/50 Hz: FL 100 LED 3K (12 V/50 Hz)

• A LED lamp (3 W).


• Safe lamp voltage: 12 V/50 Hz.
• Lamp cap: G5.3.
• Supplied with a terminal box.
•  vailable for order with lamps:
A
3 W 3000 K – FL 100 LED 3K (12 V/50 Hz)
3 W 7000 K – FL 100 LED 7K (12 V/50 Hz)
4 W 7000 K – FL 100 LED4 7K (12 V/50 Hz)
4.6 W 4000 K – FL 100 LED4.6 4K (12 V/50 Hz)
5 W 3000 K – FL 100 LED5 3K (12 V/50 Hz)
5 W 7000 K – FL 100 LED5 7K (12 V/50 Hz)

268 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


A model with a LED lamp 12 V/50 Hz and a transformer unit 220-240/12 V: FL-T 100 LED 3K

• A LED lamp (3 W).


• The delivery set includes a 220-240/12 power unit for LED lamps.
• Safe lamp voltage: 12 V.
• White warm lightning colour.
• Lamp cap: G5.3.
• Supplied with a terminal box.
•  vailable for order with lamps:
A
3 W 3000 K – FL-T 100 LED 3K
3 W 7000 K – FL-T 100 LED 7K
4 W 7000 K – FL-T 100 LED4 7K
4.6 W 4000 K – FL-T 100 LED4.6 4K
5 W 3000 K – FL-T 100 LED5 3K
5 W 7000 K – FL-T 100 LED5 7K

A model with a LED lamp 220-240 V/50 Hz: FL 100 LED 3K (220-240 V/50 V)

• A LED lamp (3 W).


• Lamp supply voltage: 220-240 V/50 Hz.
• White warm lightning colour.
• Lamp cap: GU10.
• Supplied with a terminal box.

Overall dimensions

Dimensions [mm]
Model Air pass [m2]
D D1 L L1

FL 100 141 99.4 87.5 15 0.00302

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 269


SUPPLY AND EXHAUST
PLASTIC DIFFUSERS WITH LIGHT

FL2-100 Application
Series • For supply and exhaust ventilation and air conditioning systems.
• For synchronous ventilation and backlighting of premises.
• Designed for a wall or suspended ceiling mounting.
• T he best solution for use in exhaust systems of premises with high humidity, such as bathrooms
and WCs.

Design
• Made of high quality plastic.
• T he diffuser is supplied with a LED lamp with power demand from 3 to 7 W and light temperature
from 3000 K (white warm) to 7000 K (white cold).
• Special aerodynamic shape ensures uniform air distribution.
• Easy mounting with a mounting flange and screws.
• External removable grille for technical maintenance and cleaning.
• IP rating is IPX4.

Diffuser modifications
A model with a LED lamp FL2 100 LED 3K (12 V/50 Hz) A model with a LED lamp and a transformer unit FL2-T 100 LED 3K
• A LED lamp (3 W). • A LED lamp (3 W).
• Safe lamp voltage: 12 V/50 Hz. • The delivery set includes a 100-240/12 V power unit for LED lamps.
• White warm lightning colour - 3000 K. • Safe lamp voltage: 12 V.
• Lamp cap: G5.3. • White warm lightning colour - 3000 K.
• Supplied with a terminal box. • Lamp cap: G5.3.
• Supplied with a terminal box.

Diffuser supply voltage,


Model Lamp wattage, W Light temperature, K Power unit
V/50 Hz
FL2 100 LED 3K (12 V/50 Hz) 3 3000 No 12
FL2 100 LED 7K (12 V/50 Hz) 3 7000 No 12
FL2 100 LED4 7K (12 V/50 Hz) 4 7000 No 12
FL2 100 LED4.6 4K (12 V/50 Hz) 4.6 4000 No 12
FL2 100 LED5 3K (12 V/50 Hz) 5 3000 No 12
FL2 100 LED5 7K (12 V/50 Hz) 5 7000 No 12
FL2-T 100 LED 3K 3 3000 Yes 220-240
FL2-T 100 LED 7K 3 7000 Yes 220-240
FL2-T 100 LED4 7K 4 7000 Yes 220-240
FL2-T 100 LED4.6 4K 4.6 4000 Yes 220-240
FL2-T 100 LED5 3K 5 3000 Yes 220-240
FL2-T 100 LED5 7K 5 7000 Yes 220-240
FL2 100 LED 3K (220-240 V/50 Hz) 3 3000 No 220-240

270 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Overall dimensions

Dimensions [mm]
Model Air pass [m2]
D D1 L L1

FL2-100 140 97 73.2 13.2 0.00302

Additional equipment

chrome
FL2-100 chrome

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 271


SUPPLY AND EXHAUST
METAL GRILLES

272 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Supply and exhaust
single-row metal grilles page

MVM Series 276


MVMP Series

Supply and exhaust


multiple-row metal grilles page
MVMP Series 278

Supply and exhaust


slot metal grilles page
MVMP Series 280

Supply and exhaust


single-row metal edge-raised grilles page
MVMPO Series 281

Supply and exhaust


multiple-row metal edge-raised grilles page
MVMPO Series 282

Supply and exhaust


metal slot edge-raised grilles page
MVMPO Series 284

Supply and exhaust


metal regulated grilles page
MVMPO...R Series 285

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 273


Supply and exhaust
regulated slot metal grilles page
MVMPO...Rr Series 286
MVMPO...R Series

Supply and exhaust


metal door grilles page
MVM Series 287

Supply and exhaust


metal door grilles page

MVMP Series 288

Supply and exhaust


metal door grilles page
MVMA Series 289

Supply and exhaust


metal grille page
MVM...bV A Series 290

Supply and exhaust


metal grille page

MVM...bV N Series 291

Supply and exhaust


metal grille page

MVM...b N Series 292

Supply and exhaust


metal hoods page

MVM... bVs N / bV N Series 293

Exhaust gravity
metal grille page
MVM...VJ N Series 295

Exhaust metal
hoods page

MVM...V N Series 296

274 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Supply and exhaust
metal grille page

MVM...bVL A Series 297

Supply and exhaust


metal grille page

MVM...VR N Series 298

Supply and exhaust


metal grille page
MVMP...R N / R A Series 299

Supply and exhaust


metal grille page

MVMO...b Series 301

Supply and exhaust


metal grille page
MVMO...bV Series 302

Supply and exhaust


metal grille page
MVMO…bS K1 304

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 275


SUPPLY AND EXHAUST
SINGLE-ROW GRILLES

MVM Application
Series • Decoration of exhaust vents of public, residential and industrial ventilation systems.
• For supply ventilation and air conditioning.
• Used for correct air flow distribution in premises.
• Internal or external wall and ceiling mounting.

Design
• Made of steel, galvanized steel or aluminium and are suitable for colourful polymer
painting.
• Screw fixing.
• Quality materials and zinc-phosphate treatment ensure coating integrity and provide
reliable corrosion protection.
• Modifications with a protecting insect screen are available.

Modifications
• MVM … – basic steel models with white polymer coating.
• MVM … s – steel models with white polymer coating and a protecting insect screen.
• MVM ... A – aluminium grille models with white polymer coating.
• MVM ... s A – aluminium models with white polymer coating and protecting insect
screen.
• MVM ... A (no/p) – aluminium grille models.
• MVM ... s A (no/p) – aluminium models with a protecting insect screen.
• MVM … Zn – galvanized steel grille models.
• MVM … s Zn – galvanized steel models with a protecting insect screen.
• MVM … «colour code» – colourful polymer painted models.

Colour modifications

white brown blue beige grey black


RAL 9016 RAL 8017 RAL 5005 RAL 1015 RAL 7001 RAL 9005

Overall dimensions
Dimensions, [mm]
Model Air pass, [m2]
L h A
MVM 125 125 111 0.8 0.0035
MVM 150 150 136 0.8 0.0060
MVM 200 200 182 0.8 0.0117
MVM 250 250 234 0.8 0.0166
MVM 300 300 284 0.8 0.0249

276 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


SUPPLY AND EXHAUST
SINGLE-ROW GRILLES

MVMP Application
Series • Decoration of exhaust vents of public, residential and industrial ventilation systems.
• For ventilation, air conditioning and heating.
• Used for correct air flow distribution in premises.
• Internal or external wall and ceiling mounting.

Design
• Made of steel, galvanized steel or aluminium and are suitable for colourful polymer
painting.
• Screw fixing.
• Quality materials and zinc-phosphate treatment ensure coating integrity and
provide reliable corrosion protection.
• Modifications with a protecting insect screen are available.

Modifications
• MVMP … – basic steel models with white polymer coating.
• MVMP …s – steel models with white polymer coating and a protecting insect
screen.
• MVMP ... A – aluminium grille models with white polymer coating.
• MVMP ... s A – aluminium models with white polymer coating and protecting insect
screen.
• MVMP ... A (no/p) – aluminium grille models.
• MVMP ... s A (no/p) – aluminium models with a protecting insect screen.
• MVMP …Zn – galvanized steel grille models.
• MVMP … s Zn – galvanized steel models with a protecting insect screen.
• MVMP … «colour code» – colourful polymer painted models.

Colour modifications

white brown blue beige grey black


RAL 9016 RAL 8017 RAL 5005 RAL 1015 RAL 7001 RAL 9005
Overall dimensions

Dimensions, [mm]
Model Air pass, [m2]
L H I h A
MVMP 70 70 70 56 56 0.8 0.0009
MVMP 70x140 70 140 56 126 0.8 0.0018
MVMP 100 100 100 86 86 0.8 0.0018
MVMP 100x200 100 200 86 186 0.8 0.0050
MVMP 100x300 100 300 86 288 0.8 0.0081
MVMP 125 125 125 111 111 0.8 0.0028
MVMP 130x90 130 90 116 76 0.8 0.0019
MVMP 130x170 130 170 116 156 0.8 0.0045
MVMP 140 140 140 126 126 0.8 0.0036
MVMP 150 150 150 136 136 0.8 0.0036
MVMP 150x200 150 200 136 186 0.8 0.0054
MVMP 150x210 150 210 136 196 0.8 0.0054
MVMP 150x215 150 215 136 201 0.8 0.0059
MVMP 150x250 150 250 136 236 0.8 0.0069
MVMP 150x300 150 300 136 286 0.8 0.0081
MVMP 150x350 150 350 136 336 0.8 0.0096
MVMP 155 155 155 141 141 0.8 0.0044
MVMP 170 170 170 156 156 0.8 0.0053
MVMP 175 175 175 161 161 0.8 0.0045
MVMP 175x250 175 250 161 236 0.8 0.0068
MVMP 180x90 180 90 166 76 0.8 0.0030
MVMP 180x250 180 250 166 236 0.8 0.0083
MVMP 190x170 190 170 176 156 0.8 0.0059

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 277


SUPPLY AND EXHAUST
MULTIPLE-ROW METAL GRILLES

MVMP Application
Series • Decoration of exhaust vents of public, residential and industrial ventilation systems.
• For ventilation, air conditioning and heating.
• Used for correct air flow distribution in premises.
• Internal or external wall and ceiling mounting.

Design
• Made of polymer-coated, galvanized steel or aluminium.
• Screw fixing.
• Quality materials and zinc-phosphate treatment ensure coating integrity and provide
reliable corrosion protection.
• Modifications with a protecting insect screen are available.

Modifications
• MVMP … – basic steel models with white polymer coating.
• MVMP … s – steel models with white polymer coating and a protecting insect screen.
• MVMP ... A – aluminium grille models with white polymer coating.
• MVMP ... s A – aluminium models with white polymer coating and protecting insect
screen.
• MVMP ... A (no/p) – aluminium grille models.
• MVMP ... s A (no/p) – aluminium models with a protecting insect screen.
• MVMP … Zn – galvanized steel grille models.
• MVMP … s Zn – galvanized steel models with a protecting insect screen.
• MVMP … «colour code» – colourful polymer painted models.

Colour modifications

white brown blue beige grey black


RAL 9016 RAL 8017 RAL 5005 RAL 1015 RAL 7001 RAL 9005

Overall dimensions

Dimensions, [mm] Number of


Model Air pass, [m2]
L H I h A rows
MVMP 195/2 195 195 181 181 0.8 0.0070 2
MVMP 195x245/2 195 245 181 231 0.8 0.0088 2
MVMP 200x100/2 200 100 186 186 0.8 0.0036 2
MVMP 200/2 200 200 186 186 0.8 0.0099 2
MVMP 200x250/2 200 250 186 238 0.8 0.0093 2
MVMP 200x300/2 200 300 186 286 0.8 0.0162 2
MVMP 200x350/2 200 350 186 336 0.8 0.0129 2
MVMP 200x405/2 200 405 186 391 0.8 0.0149 2
MVMP 215x150/2 215 150 201 136 0.8 0.0059 2
MVMP 240/2 240 240 226 226 0.8 0.0126 2
MVMP 240x140/2 240 140 226 126 0.8 0.0063 2
MVMP 240x190/2 240 190 226 176 0.8 0.0099 2
MVMP 245x195/2 245 195 231 181 0.8 0.0088 2
MVMP 250/2 250 250 236 236 0.8 0.0135 2
MVMP 250x80/2 250 80 236 66 0.8 0.0037 2
MVMP 250x110/2 250 110 236 96 0.8 0.0051 2
MVMP 250x140/2 250 140 236 126 0.8 0.0064 2
MVMP 250x150/2 250 150 236 136 0.8 0.0069 2
MVMP 250x170/2 250 170 236 156 0.8 0.0078 2
MVMP 250x200/2 250 200 236 186 0.8 0.0092 2
MVMP 250x300/2 250 300 236 286 0.8 0.0171 2
MVMP 250x350/2 250 350 236 336 0.8 0.0161 2
MVMP 250x400/2 250 400 236 386 0.8 0.0184 2
MVMP 250x450/2 250 450 236 436 0.8 0.0207 2
MVMP 250x500/2 250 500 236 486 0.8 0.0230 2

278 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Dimensions, [mm] Number of
Model Air pass, [m2]
L H I h A rows
MVMP 300x100/3 300 100 286 86 0.8 0.0054 3
MVMP 300x210/3 300 210 286 196 0.8 0.0162 3
MVMP 300x250/3 300 250 286 236 0.8 0.0189 3
MVMP 300x290/3 300 290 286 276 0.8 0.0230 3
MVMP 300/3 300 300 286 286 0.8 0.0243 3
MVMP 305x150/3 305 150 291 136 0.8 0.0084 3
MVMP 305x200/3 305 200 291 186 0.8 0.0112 3
MVMP 305x250/3 305 250 291 236 0.8 0.0140 3
MVMP 305x300/3 305 300 291 286 0.8 0.0168 3
MVMP 305x350/3 305 350 291 336 0.8 0.0196 3
MVMP 305x400/3 305 400 291 386 0.8 0.0224 3
MVMP 305x450/3 305 450 291 436 0.8 0.0252 3
MVMP 305x500/3 305 500 291 486 0.8 0.0280 3
MVMP 350x150/3 350 150 336 136 0.8 0.0096 3
MVMP 350x200/3 350 200 336 186 0.8 0.0129 3
MVMP 350x250/3 350 250 336 236 0.8 0.0161 3
MVMP 350x300/3 350 300 336 286 0.8 0.0193 3
MVMP 350/3 350 350 336 336 0.8 0.0225 3
MVMP 350x400/3 350 400 336 386 0.8 0.0257 3
MVMP 350x450/3 350 450 336 436 0.8 0.0289 3
MVMP 350x500/3 350 500 336 486 0.8 0.0321 3
MVMP 360x140/3 360 140 346 126 0.8 0.0093 3
MVMP 360x180/3 360 180 346 166 0.8 0.0119 3

Dimensions, [mm] Number of


Model Air pass, [m2]
L H I h A rows
MVMP 400x200/4 400 200 386 186 0.8 0.0147 4
MVMP 400x250/4 400 250 436 236 0.8 0.0184 4
MVMP 400x300/4 400 300 386 286 0.8 0.0324 4
MVMP 400x350/4 400 350 386 336 0.8 0.0257 4
MVMP 400/4 400 400 386 386 0.8 0.0294 4
MVMP 400x450/4 400 450 386 436 0.8 0.0331 4
MVMP 400x500/4 400 500 386 486 0.8 0.0367 4
MVMP 450x250/4 450 250 436 236 0.8 0.0207 4
MVMP 450x300/4 450 300 436 286 0.8 0.0248 4
MVMP 450x350/4 450 350 436 336 0.8 0.0289 4
MVMP 450x400/4 450 400 436 386 0.8 0.0331 4
MVMP 450/4 450 450 436 436 0.8 0.0372 4
MVMP 450x500/4 450 500 436 486 0.8 0.0413 4

Dimensions, [mm] Number of


Model Air pass, [m2]
L H I h A rows
MVMP 500x250/5 500 250 486 236 0.8 0.0236 5
MVMP 500x300/5 500 300 486 286 0.8 0.0276 5
MVMP 500x350/5 500 350 486 336 0.8 0.0321 5
MVMP 500x400/5 500 400 486 386 0.8 0.0367 5
MVMP 500x450/5 500 450 486 436 0.8 0.0413 5
MVMP 500/5 500 500 486 486 0.8 0.0459 5

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 279


SUPPLY AND EXHAUST
SLOT METAL GRILLES

MVMP Application
Series • Decoration of exhaust vents of public, residential and industrial ventilation systems.
• For ventilation, air conditioning and heating.
• Used for correct air flow distribution in premises.
• Internal or external wall and ceiling mounting.

Design
• Made of steel, galvanized steel or aluminium and are suitable for colourful polymer
painting.
• Screw fixing.
• Quality materials and zinc-phosphate treatment ensure coating integrity and provide
reliable corrosion protection.
• Modifications with a protecting insect screen are available.

Modifications
• MVMP … – basic steel models with white polymer coating.
• MVMP … s – steel models with white polymer coating and a protecting insect screen.
• MVMP ... A – aluminium grille models with white polymer coating.
• MVMP ... s A – aluminium models with white polymer coating and protecting insect
screen.
• MVMP ... A (no/p) – aluminium grille models.
• MVMP ... s A (no/p) – aluminium models with a protecting insect screen.
• MVMP … Zn – galvanized steel grille models.
• MVMP … s Zn – galvanized steel models with a protecting insect screen.
• MVMP … «colour code» – colourful polymer painted models.

Colour modifications

white brown blue beige grey black


RAL 9016 RAL 8017 RAL 5005 RAL 1015 RAL 7001 RAL 9005

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2] Number of sections
L H I h A
MVMP 305x40/3 305 40 291 26 0.8 0.0022 3
MVMP 305x90/3 305 90 291 76 0.8 0.0050 3
MVMP 305x100/3 305 100 291 86 0.8 0.0056 3
MVMP 370x40/3 370 40 356 26 0.8 0.0027 3
MVMP 400x40/4 400 40 386 26 0.8 0.0029 4
MVMP 475x85/4 475 85 461 71 0.8 0.0074 4

MVMP 495x63/4 495 63 481 49 0.8 0.0057 4

MVMP 500x40/5 500 40 486 26 0.8 0.0037 5

MVMP 500x60/5 500 60 486 46 0.8 0.0055 5

MVMP 500x90/5 500 90 486 76 0.8 0.0083 5

MVMP 650x70/7 650 70 636 56 0.8 0.0084 7

MVMP 650x100/7 650 100 636 86 0.8 0.0119 7

280 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


SUPPLY AND EXHAUST
SINGLE-ROW EDGE-RAISED METAL GRILLES

MVMPO Application
Series • Decoration of exhaust vents of public, residential and industrial ventilation systems.
• For ventilation, air conditioning and heating.
• Used for correct air flow distribution in premises.
• Internal or external wall and ceiling mounting.

Design
• Made of steel, galvanized steel or aluminium and are suitable for colourful polymer
painting.
• Edge-raised grille design.
• Screw fixing.
• Quality materials and zinc-phosphate treatment ensure coating integrity and
provide reliable corrosion protection.
• Modifications with a protecting insect screen are available.

Modifications
• MVMPO … – basic steel models with white polymer coating.
• MVMPO … s – steel models with white polymer coating and a protecting insect
screen.
• MVMPO ... A – aluminium grille models with white polymer coating.
• MVMPO ... s A – aluminium models with white polymer coating and protecting
insect screen.
• MVMPO ... A (no/p) – aluminium grille models.
• MVMPO ... s A (no/p) – aluminium models with a protecting insect screen.
• MVMPO …Zn – galvanized steel grille models.
• MVMPO … s Zn – galvanized steel models with a protecting insect screen.
• MVMPO ... «colour code» – colourful polymer painted models.

Colour modifications

white brown blue beige grey black


RAL 9016 RAL 8017 RAL 5005 RAL 1015 RAL 7001 RAL 9005

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2]
L H I h A
MVMPO 70x140 70 140 56 126 5.5 0.0018
MVMPO 100 100 100 86 86 5.5 0.0018
MVMPO 100x200 100 200 86 186 5.5 0.0050
MVMPO 100x300 100 302 86 288 5.5 0.0086
MVMPO 125 125 125 111 111 5.5 0.0033
MVMPO 130x170 130 170 116 156 5.5 0.0045
MVMPO 130x90 130 90 116 76 5.5 0.0018
MVMPO 140 140 140 126 126 5.5 0.0036
MVMPO 140x180 140 180 126 166 5.5 0.0045
MVMPO 140x240 140 240 126 226 5.5 0.0063
MVMPO 150 150 150 136 136 5.5 0.0036
MVMPO 150x210 150 210 136 196 5.5 0.0054
MVMPO 150x215 150 215 136 201 5.5 0.0059
MVMPO 155 155 155 141 141 5.5 0.0041

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 281


SUPPLY AND EXHAUST
MULTIPLE-ROW EDGE-RAISED METAL GRILLES

MVMPO Application
Series • Decoration of exhaust vents of public, residential and industrial ventilation systems.
• For ventilation, air conditioning and heating.
• Used for correct air flow distribution in premises.
• Internal or external wall and ceiling mounting.

Design
• Made of steel, galvanized steel or aluminium and are suitable for colourful polymer
painting.
• Edge-raised grille design.
• Screw fixing.
• Quality materials and zinc-phosphate treatment ensure coating integrity and provide
reliable corrosion protection.
• Modifications with a protecting insect screen are available.

Modifications
• MVMPO … – basic steel models with white polymer coating.
• MVMPO ... A – aluminium grille models with white polymer coating.
• MVMPO ... s A – aluminium models with white polymer coating and protecting insect
screen.
• MVMPO ... A (no/p) – aluminium grille models.
• MVMPO ... s A (no/p) – aluminium models with a protecting insect screen.

Colour modifications • MVMPO … Zn – galvanized steel grille models.


• MVMPO … s – steel models with white polymer coating and a protecting insect screen.
• MVMPO … s Zn – galvanized steel models with a protecting insect screen.
• MVMPO «colour code» – colourful polymer painted models.
white brown blue beige grey black
RAL 9016 RAL 8017 RAL 5005 RAL 1015 RAL 7001 RAL 9005

Overall dimensions

Dimensions, [mm] Number of


Model Air pass, [m2]
L H I h A rows
MVMPO 150x250/2 150 250 136 236 5.5 0.0068 2
MVMPO 150x350/2 150 350 136 336 5.5 0.0104 2
MVMPO 180x250/2 180 250 166 236 5.5 0.0068 2
MVMPO 195x245/2 195 245 181 231 5.5 0.0135 2
MVMPO 200/2 200 200 186 186 5.5 0.0099 2
MVMPO 200x100/2 200 100 186 86 5.5 0.0036 2
MVMPO 200x250/2 200 252 186 238 5.5 0.0135 2
MVMPO 200x300/2 200 300 186 286 5.5 0.0162 2
MVMPO 200x350/2 200 350 186 336 5.5 0.0199 2
MVMPO 200x405/2 200 405 186 391 5.5 0.0235 2
MVMPO 215x150/2 215 150 201 136 5.5 0.0072 2
MVMPO 225x150/2 225 150 211 136 5.5 0.0072 2
MVMPO 225/2 225 225 211 211 5.5 0.0117 2
MVMPO 240/2 240 240 226 226 5.5 0.0126 2
MVMPO 240x165/2 240 165 226 151 5.5 0.0081 2
MVMPO 240x195/2 240 195 231 181 5.5 0.0099 2
MVMPO 250/2 250 250 236 236 5.5 0.0135 2
MVMPO 250x110/2 250 110 236 96 5.5 0.0045 2
MVMPO 250x140/2 250 140 236 126 5.5 0.0072 2
MVMPO 250x150/2 250 150 236 136 5.5 0.0072 2
MVMPO 250x170/2 250 170 236 156 5.5 0.0090 2
MVMPO 250x200/2 250 200 236 186 5.5 0.0108 2
MVMPO 250x300/2 250 300 236 286 5.5 0.0162 2
MVMPO 250x350/2 250 350 236 336 5.5 0.0208 2
MVMPO 250x400/2 250 400 236 386 5.5 0.0235 2
MVMPO 250x450/2 250 450 236 436 5.5 0.0271 2
MVMPO 250x500/2 250 500 236 486 5.5 0.0298 2

282 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Dimensions, [mm] Number of
Model Air pass, [m2]
L H I h A rows
MVMPO 300/3 300 300 286 286 5.5 0.0243 3
MVMPO 305x100/3 305 100 291 86 5.5 0.0068 3
MVMPO 305x150/3 305 150 291 136 5.5 0.0108 3
MVMPO 305x350/3 305 350 291 336 5.5 0.0311 3
MVMPO 305x400/3 305 400 291 386 5.5 0.0352 3
MVMPO 305x450/3 305 450 291 436 5.5 0.0406 3
MVMPO 305x500/3 305 500 291 486 5.5 0.0447 3
MVMPO 350x200/3 350 200 336 186 5.5 0.0162 3
MVMPO 350x250/3 350 250 336 236 5.5 0.0203 3
MVMPO 350x300/3 350 300 336 286 5.5 0.0257 3
MVMPO 350/3 350 350 336 336 5.5 0.0311 3
MVMPO 350x400/3 350 400 336 386 5.5 0.0352 3
MVMPO 350x450/3 350 450 336 436 5.5 0.0406 3
MVMPO 350x500/3 350 500 336 486 5.5 0.0447 3
MVMPO 360x140/3 360 140 346 126 5.5 0.0108 3
MVMPO 360x180/3 360 180 346 166 5.5 0.0135 3

Dimensions, [mm] Number of


Model Air pass, [m2]
L H I h A rows
MVMPO 400/4 400 400 386 386 5.5 0.0270 4
MVMPO 400x200/4 400 200 386 186 5.5 0.0217 4
MVMPO 400x250/4 400 250 386 236 5.5 0.0468 4
MVMPO 400x300/4 400 300 386 286 5.5 0.0325 4
MVMPO 400x350/4 400 350 386 336 5.5 0.0415 4
MVMPO 400x450/4 400 450 386 436 5.5 0.0541 4
MVMPO 400x500/4 400 500 386 486 5.5 0.0596 4
MVMPO 450x250/4 450 250 436 236 5.5 0.0271 4
MVMPO 450x300/4 450 300 436 286 5.5 0.0343 4
MVMPO 450x350/4 450 350 436 336 5.5 0.0415 4
MVMPO 450x400/4 450 400 436 386 5.5 0.0469 4
MVMPO 450/4 450 450 436 436 5.5 0.0541 4
MVMPO 450x500/4 450 500 436 486 5.5 0.0596 4

Dimensions, [mm] Number of


Model Air pass, [m2]
L H I h A rows
MVMPO 500x250/5 500 250 486 236 5.5 0.0338 5
MVMPO 500x300/5 500 300 486 286 5.5 0.0429 5
MVMPO 500x350/5 500 350 486 336 5.5 0.0519 5
MVMPO 500x400/5 500 400 486 386 5.5 0.0587 5
MVMPO 500x450/5 500 450 486 436 5.5 0.0677 5

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 283


SUPPLY AND EXHAUST
EDGE-RAISED SLOT METAL GRILLES

MVMPO Application
Series • Decoration of exhaust vents of public, residential and industrial ventilation systems.
• For ventilation, air conditioning and heating.
• Used for correct air flow distribution in premises.
• Internal or external wall and ceiling mounting.

Design
• Made of steel, galvanized steel or aluminium and are suitable for colourful polymer
painting.
• Edge-raised grille design.
• Screw fixing.
• Quality materials and zinc-phosphate treatment ensure coating integrity and provide
reliable corrosion protection.
• Models with insect screen are available.

Modifications
• MVMPO … – basic steel models with white polymer coating.
• MVMPO … s – steel models with white polymer coating and a protecting insect screen.
• MVMPO ... A – aluminium grille models with white polymer coating.
• MVMPO ... s A – aluminium models with white polymer coating and protecting insect
screen.
• MVMPO ... A (no/p) – aluminium grille models.
• MVMPO ... s A (no/p) – aluminium models with a protecting insect screen.

Colour modifications
• MVMPO … Zn – galvanized steel grille models.
• MVMPO … s Zn – galvanized steel models with a protecting insect screen.
• MVMPO … «colour code» – colourful polymer painted models.

white brown blue beige grey black


RAL 9016 RAL 8017 RAL 5005 RAL 1015 RAL 7001 RAL 9005

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2] Number of sections
L H I h A

MVMPO 225x75/2 225 75 211 61 5.5 0.0027 2

MVMPO 250x80/2 250 80 236 66 5.5 0.0027 2

MVMPO 300x75/3 300 75 286 61 5.5 0.0041 3


MVMPO 305x40/3 305 40 291 26 5.5 0.0014 3
MVMPO 305x90/3 305 90 291 76 5.5 0.0054 3
MVMPO 370x40/3 370 43 352 22 5.5 0.0027 3

MVMPO 380x40/4 380 43 366 29 5.5 0.0054 4

MVMPO 400x40/4 400 40 386 26 5.5 0.0018 4

MVMPO 400x80/4 400 80 386 66 5.5 0.0072 4

MVMPO 475x85/5 475 85 461 71 5.5 0.0068 5

MVMPO 500x40/5 500 40 488 22 5.5 0.0045 5

MVMPO 500x60/5 500 60 486 46 5.5 0.0045 5

MVMPO 500x90/5 500 90 486 76 5.5 0.0090 5

MVMPO 650x60/6 650 60 636 46 5.5 0.0063 6


MVMPO 650x65/6 650 65 632 47 5.5 0.0081 6
MVMPO 650x70/6 650 70 636 56 5.5 0.0081 6
MVMPO 650x100/6 650 100 636 86 5.5 0.0108 6

284 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


SUPPLY AND EXHAUST
REGULATED METAL GRILLES

MVMPO...R Application
Series • Decoration of exhaust vents of public, residential and industrial ventilation systems.
• For ventilation, air conditioning and heating.
• Used for correct air flow distribution in premises.
• Internal or external wall and ceiling mounting.

Design
• Made of steel or aluminium and are suitable for colourful polymer painting.
• Quality materials and zinc-phosphate treatment ensure coating integrity and
provide reliable corrosion protection.
• Edge-raised grille design.
• Equipped with a movable flap for air flow regulation.
• Screw fixing.

Modifications
• MVMPO … R – basic steel models with white polymer coating.
• MVMPO…R A – aluminium grille models with white polymer coating.
• MVMPO…R A (no/p) – aluminium grille models.
• MVMPO …R «colour code» – colourful polymer painted models.

Colour modifications

white brown blue beige grey black


RAL 9016 RAL 8017 RAL 5005 RAL 1015 RAL 7001 RAL 9005

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2]
L H I h A
MVMPO 155 R 155 155 132 132 9 0.0047
MVMPO 150x200 R 150 200 132 182 9 0.0067
MVMPO 160 R 160 160 137 137 9 0.0051
MVMPO 200x150 R 200 150 182 132 9 0.0061
MVMPO 200 R 200 200 182 182 9 0.0099
MVMPO 200x250 R 200 250 182 232 9 0.0135
MVMPO 200x300 R 200 300 182 282 9 0.0162
MVMPO 250x200 R 250 200 232 182 9 0.0108
MVMPO 250x300 R 250 300 232 282 9 0.0171
MVMPO 300x200 R 300 200 282 182 9 0.0172
MVMPO 300x250 R 300 250 282 232 9 0.0204

open closed

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 285


SUPPLY AND EXHAUST
REGULATED SLOT METAL GRILLES

MVMPO...Rr Application
Series • Decoration of exhaust vents of public, residential and industrial ventilation systems.
• For ventilation, air conditioning and heating.
• Used for correct air flow distribution in premises.
• Internal or external wall and ceiling mounting.

Design
• Made of steel or aluminium and are suitable for colourful polymer painting.
• Quality materials and zinc-phosphate treatment ensure coating integrity and provide
reliable corrosion protection.
• Edge-raised grille design.

MVMPO...R • Equipped with a movable flap for air flow regulation.


• Regulation with a wheel (MVMPO…Rs) or a tilt wand (MVMPO…R).
Series • Screw fixing.

Modifications
• MVMPO…R / MVMPO…Rr – basic steel models with white polymer coating.
• MVMPO…R A / MVMPO…Rr A – aluminium grilles with white polymer coating.
• MVMPO...R A (no/p) / MVMPO...Rr A (no/p) is made of Aluminium.
• MVMPO…R «colour code» / MVMPO…Rr «colour code» – colourful grilles with polymer
coating.

Colour modifications

white brown blue beige grey black


RAL 9016 RAL 8017 RAL 5005 RAL 1015 RAL 7001 RAL 9005

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2]
L H I h A
MVMPO 370x40 Rr 370 40 356 29 9 0.0033
MVMPO 380x40 Rr 380 43 366 29 9 0.0035
MVMPO 495x65 Rr 495 65 477 47 9 0.0072
MVMPO 500x40 Rr 500 40 482 29 9 0.0054
MVMPO 500x90 Rr 500 90 482 72 9 0.0090
MVMPO 650x60 Rr 650 60 632 42 9 0.0063
MVMPO 650x65 Rr 650 65 632 44 9 0.0110

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2]
L H I h A
MVMPO 380x40 R 380 43 366 29 9 0.0035

open closed open closed

286 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


SUPPLY AND EXHAUST
METAL DOOR GRILLES

MVM Application
Series • Mounting in door leaves of bathrooms, kitchens, etc.
• Suitable for installation into window sills for correct warm air distribution from
radiators.
• Used to arrange correct air circulation in premises.

Design
• Made of polymer-coated or galvanized steel and are suitable for painting in various
colours.
• Quality materials and zinc-phosphate treatment ensure coating integrity and
provide reliable corrosion protection.
• Screw or lug fixing.
• Modifications with a protecting insect screen are available.
• Various decorative ornaments.
• Minimum door leaf thickness for grilles with fixing lugs is 30 mm.

Modifications
• MVM… – basic steel models with white polymer coating and screw fixing.
• MVM…s – steel grilles with white polymer coating and a protecting insect screen.
• MVM…K – steel grilles with white polymer coating and fixing lugs.
• MVM…s K – steel models with white polymer coating, fixing lugs and a protecting
insect screen.
• MVM…Zn – galvanized steel models with screw fixing.
• MVM…s Zn – galvanized steel models with screw fixing and a protecting insect
screen.
• MVM…K Zn – galvanized steel models with fixing lugs.
• MVM…s K Zn – galvanized steel models with fixing lugs and a protecting insect
screen.
• MVM… «colour code» – colourful polymer painted models.

Colour modifications

white brown blue beige grey black


RAL 9016 RAL 8017 RAL 5005 RAL 1015 RAL 7001 RAL 9005

Overall dimensions

Dimensions, [mm] Number of


Model Air pass, [m2]
L H l h A sections
MVM 250x80/5-3 250 80 236 66 11.5 5 0.0055
MVM 475x80/10-3 475 80 461 71 11.5 10 0.0103

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 287


SUPPLY AND EXHAUST
METAL DOOR GRILLES

MVMP Application
Series • Mounting in door leaves of bathrooms, kitchens, etc.
• Suitable for installation into window sills for correct warm air distribution from radiators.
• Used to arrange correct air circulation in premises.

Design
• Made of polymer-coated or galvanized steel and are suitable for painting in various
colours.
• Quality materials and zinc-phosphate treatment ensure coating integrity and provide
reliable corrosion protection.
• Screw fixing.
• Modifications with an insect screen are available.
• Various decorative ornaments.
• Minimum door leaf thickness for grilles with fixing lugs is 30 mm.

Grille modifications
• MVMP… – basic steel models with white polymer coating and screw fixing.
• MVMP…s – steel grilles with white polymer coating equipped with a protecting insect
screen.
• MVMP…Zn – galvanized steel grilles with screw fixing.
• MVMP…s Zn – galvanized steel grilles with screw fixing and a protecting insect screen.
• MVMP…«colour code» – colourful polymer painted models.

Colour modifications

white brown blue beige grey black


RAL 9016 RAL 8017 RAL 5005 RAL 1015 RAL 7001 RAL 9005

Decorative ornament types

MVMP...-2 MVMP...-3 MVMP...-4 MVMP...-5 MVMP...-6

Overall dimensions

Dimensions, [mm] Number of


Model Air pass, [m2]
L H l h A sections
MVMP 250x80 250 80 236 66 0.8 5 0.0055
MVMP 350x80 350 80 338 68 0.8 6 0.0067
MVMP 430x80 430 80 418 68 0.8 7 0.0083
MVMP 450x80 450 80 438 68 0.8 8 0.0094
MVMP 475*80 475 80 461 71 0.8 10 0.0110

288 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


SUPPLY AND EXHAUST
METAL DOOR GRILLES

MVMA Application
Series • Mounting in door leaves of bathrooms, kitchens, etc.
• Suitable for installation into window sills for correct warm air distribution from
radiators.
• Used to arrange correct air circulation in premises.

Design
• Made of polymer-coated or galvanized steel and are suitable for painting in various
colours.
• Fixing with lugs.
• Modifications with a protecting insect screen are available.
• Minimum door leaf thickness is 32 mm.

Grille modifications
• MVMA…An – grilles from anodized aluminium
• MVMA…«colour code» – colourful polymer painted models.
• MVMA…s – models from aluminium with a protecting insect screen.
• MVMA…s An – models from anodized aluminium and a protecting insect screen.

Colour modifications

white brown blue beige grey black


RAL 9016 RAL 8017 RAL 5005 RAL 1015 RAL 7001 RAL 9005

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2]
L H
MVMA 400x60 400 60 0.0062
MVMA 400x80 475 80 0.0093
MVMA 400x100 400 100 0.0120
MVMA 480x80 480 80 0.0120
MVMA 500x60 500 60 0.0078
MVMA 500x80 500 80 0.0120
MVMA 500x100 500 100 0.0156
MVMA 600x60 600 60 0.0093
MVMA 600x80 600 80 0.0140
MVMA 600x100 600 100 0.0186
MVMA 800x60 800 60 0.0120
MVMA 800x80 800 80 0.0186
H1
H

MVMA 800x100 800 100 0.0248


MVMA 1000x60 1000 60 0.0160
MVMA 1000x80 1000 80 0.0256
MVMA 1000x100 1000 100 0.0326

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 289


SUPPLY AND EXHAUST
METAL GRILLE

MVM...bV A Application
Series • Decoration of supply and exhaust vents of public, residential and industrial ventilation
systems.
• Applicable for HVAC systems.
• Used for correct air flow distribution in premises.

Design
• Made of aluminium.
• Mounting with fixing lugs.
• Equipped with a round Ø 100 mm spigot for connection to air ducts.

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2]
D L
MVM 101 bV A 101 24 0.0024

290 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


MVM...bV N Application
Series • Decoration of supply and exhaust vents of public, residential and industrial
ventilation systems.
• Applicable for HVAC systems.
• Used for correct air flow distribution in premises.

Design
• Made of stainless steel.
• Insect screen included.
• Mounting with fixing lugs.
• Equipped with a round Ø 100, 125, 150, 200 mm spigot for connection to air ducts.

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2]
D D1 L
MVM 100 bV N 96 150 134 0.0048
MVM 125 bV N 119 184 165 0.0082
MVM 150 bV N 143 205 190 0.0126

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 291


SUPPLY AND EXHAUST METAL
GRILLE

MVM...b N Application
Series • Decoration of supply and exhaust vents of public, residential and industrial
ventilation systems.
• Applicable for HVAC systems.
• Used for correct air flow distribution in premises.

Design
• Made of stamped stainless steel.
• Rubber seals for tight contact to the wall.
• Fixing with screws.

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2]
D D1 L
MVM 100 b N 95 133 22 0.0057
MVM 125 b N 122 165 24 0.0093
MVM 150 b N 144 190 26 0.0138

292 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


SUPPLY AND EXHAUST
METAL HOODS

MVM...bVs N Application
Series • Decoration of supply and exhaust vents of public, residential and industrial
ventilation systems.

Design
• Made of stainless steel.
• Insect screen included.
• Rubber seals for tight contact to the wall.
• Fitted with a round Ø 100, 125, 150, 160 or 200 mm spigot for connection to the air
ducts.
• Fixation to the wall with screws.

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2 ]
D D1 L
MVM 102 bVs N 97 133 52 0.0048
MVM 122 bVs N 120 165 52 0.0082
MVM 152 bVs N 145 192 62 0.0126
MVM 162 bVs N 155 192 62 0.0135
MVM 202 bVs N 195 253 73 0.0178

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 293


SUPPLY AND EXHAUST METAL
HOODS

MVM...bV N Application
Series • Decoration of supply and exhaust vents of public, residential and industrial ventilation
systems.
• Applicable for HVAC systems.

Design
• Made of stainless steel.
• Directing vanes and an insect screen included.
• Rubber seals for tight contact to the wall.
• Equipped with a round Ø 100, 125 or 150 mm
spigot for connection to air ducts.
• Fixing with screws.

Overall dimensions
Dimensions, [mm]
Model Air pass, [m2]
D D1 L
MVM 102 bV N 97 133 52 0.0048
MVM 122 bV N 120 165 52 0.0082
MVM 152 bV N 145 192 62 0.0126
MVM 202 bV N 195 253 62 0.0178

294 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


EXHAUST GRAVITY METAL
GRILLE

MVM...VJ N Application
Series • Decoration of exhaust vents of public, residential and industrial ventilation systems.
• Applicable for exhaust HVAC systems.

Design
• Made of stainless steel.
• Fixing with screws.
• Rubber seals for tight contact to the wall.

Overall dimensions
Dimensions, [mm]
Model Air pass, [m2]
D H L
MVM 100 VJ N 97 137 x 137 52 0.0070
MVM 125 VJ N 120 167 x 167 52 0.0112

H
MVM 150 VJ N 145 167 x 167 62 0.0164

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 295


EXHAUST METAL HOODS

MVM...V N Application
Series • Decoration of exhaust vents of public, residential and industrial ventilation systems.

Design
• Made of stainless steel.
• Back valve included.
• Rubber seals for tight contact to the wall.
• Equipped with a round Ø 100, 125 or 150 mm spigot for connection to air ducts.
• Fixing with screws.

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2]
D H L

526
MVM 102 V N 97 137 x 137 52 0.0071

H
MVM 122 V N 120 167 x 167 52 0.0113
MVM 152 V N 145 167 x 167 62 0.0165

296 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


SUPPLY AND EXHAUST METAL
GRILLE

MVM...bVL A Application
Series • Decoration of supply and exhaust vents of public, residential and industrial
ventilation systems.
• Applicable for HVAC systems.
• Used for correct air flow distribution in premises.

Design
• Made of cast aluminium.
• Equipped with a round Ø 100, 125 or 150 mm spigot for connection to air ducts.
• Insect screen included.
• Rubber seals for tight contact to the wall.
• Fixing with screws.

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2]
D D1 L
MVM 100 bVL A 97 140 52 0.0045
MVM 125 bVL A 120 178 52 0.0067
MVM 150 bVL A 145 178 62 0.0115

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 297


SUPPLY AND EXHAUST METAL
GRILLE

MVM...VR N Application
Series • Decoration of supply and exhaust vents of public, residential and industrial ventilation
systems.
• Applicable for HVAC systems.
• Used for correct air flow distribution in premises.

Design
• Made of stainless steel.
• Mounting to rectangular 55x110 and 60x204 mm air ducts with fixing lugs.

Overall dimensions
Dimensions, [mm]
Model Air pass, [m2]

HxB
HxB L
MVM 110*54 VR N 110x54 25 0.0028
MVM 205*61 VR N 205x61 30 0.0042

298 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


SUPPLY AND EXHAUST METAL
GRILLE

MVMP...R N Application
Series • Decoration of supply and exhaust vents of public, residential and industrial
ventilation systems.
• Applicable for HVAC systems.
• Used for correct air flow distribution in premises.

Design
• Made of stainless steel.
• Movable flap for air flow control.
• Fixing with screws.

Overall dimensions

Dimensions, [mm]
Model Air pass, [m2]

H1

H
B1 H1 B H
MVMP 260*90 R N 225 75 260 90 0.0036
MVMP 260*165 R N 225 150 260 165 0.0085 B1
MVMP 260*240 R N 225 225 260 240 0.0127 B

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 299


SUPPLY AND EXHAUST METAL GRILLE

MVMP...R A Application
Series • Decoration of supply and exhaust vents of public, residential and industrial
ventilation systems.
• Applicable for HVAC systems.
• Used for correct air flow distribution in premises.

Design
• Made of aluminium.
• Movable flap for air flow control.
• Fixing with screws.

Overall dimensions
Dimensions, [mm]
Model Air pass, [m2]

H1

H
B1 H1 B H
MVMP 260*90 R A 225 75 260 90 0.0036
MVMP 260*165 R A 225 150 260 165 0.0085 B1
MVMP 260*240 R A 225 225 260 240 0.0127 B

300 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


SUPPLY AND EXHAUST
ROUND METAL GRILLES

MVMO1…b Application
Series • Decoration of exhaust vents of public, residential and industrial ventilation
systems.
• For ventilation, air conditioning and heating.
• Used for correct air flow distribution in premises.
• Internal or external wall and ceiling mounting.

Design
• Made of steel, galvanized steel, stainless steel or aluminium and are suitable for
colourful polymer painting.
• Screw fixing.
• Quality materials and zinc-phosphate treatment ensure coating integrity and
provide reliable corrosion protection.
• Equipped with a protecting insect screen.

Modifications
• MVMO1…bs – basic white polymer coated grilles.
• MVMO1…bs A – aluminium white polymer coated grilles with a protecting insect
screen.
• MVMO1…bs An – grilles made of anodized brushed aluminium with a protecting
insect screen.
• MVMO1…bs Ap – grilles made of polished aluminium with a protecting insect screen.
• MVMO1…bs N – grilles made of stainless steel with a protecting insect screen.
• MVMO1…bs Zn – grilles made of galvanized steel with a protecting insect screen.
• MVMO1…bs "colour code" – colourful polymer painted models.

Colour modifications

white brown blue beige grey black


RAL 9016 RAL 8017 RAL 5005 RAL 1015 RAL 7001 RAL 9005

Overall dimensions ‘'

Dimensions [mm]
Model Air pass [m2]
D B B1 L
MVMO1 100 bs 142 1.3 8.4 114 0.0051

%
/
%

MVMO1…bs / MVMO1…bs A MVMO1…bs Zn MVMO1…bs An MVMO1…bs Ap / MVMO1…bs N

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 301


SUPPLY AND EXHAUST ROUND
EDGE-RAISED METAL GRILLES

MVMO…bV Application
Series • Decoration of exhaust vents of public, residential and industrial ventilation
systems.
• For ventilation, air conditioning and heating.
• Used for correct air flow distribution in premises.
• Internal or external wall and ceiling mounting.

Design
• Made of steel, galvanized steel, stainless steel or aluminium and are suitable for colourful
polymer painting.
• Edge-raised grille design.
• Quality materials and zinc-phosphate treatment ensure coating integrity and
provide reliable corrosion protection.
• Modifications with a protecting insect screen.

Colour modifications

white brown blue beige grey black


RAL 9016 RAL 8017 RAL 5005 RAL 1015 RAL 7001 RAL 9005

Modifications

Round grille with a flange (bV): MVMO…bV

• Equipped with a flange for connection to round air ducts.


• MVMO…bV – steel grilles with white polymer coating.
• MVMO…bV A – aluminium grilles with white polymer coating.
• MVMO…bVs An – grilles made of anodized brushed aluminium with a protecting
insect screen.
• MVMO…bVs Ap – grilles made of polished aluminium with a protecting insect screen.
• MVMO…bVs N – grilles made of stainless steel with a protecting insect screen.
• MVMO…bVs Zn – grilles made of galvanized steel with a protecting insect screen.
• MVMO … bV "colour code" – colourful polymer painted models.

Round grille with a flange and a lip seal (bV1): MVMO…bV1

• Equipped with a flange for connection to round air ducts.


• MVMO…bV1 – steel grilles with white polymer coating.
• MVMO…bV1 A – grilles made of white polymer coated aluminium.
• MVMO…bV1s An – grilles made of anodized brushed aluminium with a protecting
insect screen.
• MVMO…bV1s Ap – grilles made of polished aluminium with a protecting insect screen.
• MVMO…bV1s N – grilles made of stainless steel with a protecting insect screen.
• MVMO…bV1s Zn – grilles made of galvanizes steel with a protecting insect screen.
• MVMO…bV1 "colour code" – colourful polymer painted models.

302 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Round grille with a flange and springs (bV K): MVMO…bV K

• Equipped with a flange for connection to round air ducts.


• MVMO…bV K – steel white polymer coated grilles.
• MVMO…bV K A – aluminium white polymer coated grilles.
• MVMO…bVs K An – grilles made of anodized brushed aluminium with a protecting
insect screen.
• MVMO…bVs K Ap – grilles made of polished aluminium with a protecting insect
screen.
• MVMO…bVs K N – grilles made of stainless steel with a protecting insect screen.
• MVMO…bVs K Zn – grilles made of galvanized steel with a protecting insect screen.
• MVMO…bV K "colour code" – colourful polymer painted models.

Overall dimensions

Dimensions [mm] Fig.


Model Air pass [m2]
D D1 L no.

MVMO 100 bV 1, 2
MVMO 100 bV1 99 129 48 0.0051 1, 3
MVMO 100 bV K 1, 4
‘'
MVMO 125 bV 1, 2
MVMO 125 bV1 124 154.5 48 0.0083 1, 3
MVMO 125 bV K 1, 4
 ‘'

 ‘'

 ‘'
MVMO 150 bV 1, 2
MVMO 150 bV1 149 179.5 48 0.0118 1, 3
MVMO 150 bV K 1, 4
/ / /
MVMO 160 bV 1, 2
MVMO 160 bV1 159 189.5 48 0.0138 1, 3 Fig. 1 Fig. 2
Fig. 3 Fig. 4
MVMO 160 bV K 1, 4
MVMO 200 bV 1, 2
MVMO 200 bV1 198 229 48 0.0214 1, 3
MVMO 200 bV K 1, 4

Polymer coated steel / Galvanized steel Anodized brushed aluminum Polished aluminum / stainless steel
polymer coated aluminium

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 303


SUPPLY AND EXHAUST ROUND
EDGE-RAISED METAL GRILLES

MVMO…bS K1 Application
Series • Decoration of exhaust vents of public, residential and industrial ventilation systems.
• For ventilation, air conditioning and heating.
• Used for correct air flow distribution in premises.
• Internal/external wall and ceiling mounting.

Design
• Made of steel, galvanized steel, stainless steel or aluminium and are suitable for colourful
polymer painting.
• Equipped with a spacer mechanism for mounting in a round ventilation hole without
additional fastening elements.
• Quality materials and zinc-phosphate treatment ensure coating integrity and provide
reliable corrosion protection.
• Modifications with a protecting insect screen.

Modifications
• Equipped with a plastic spreader gearing to mount in a round air vent.
• MVMO…bs K1 – steel grilles with white polymer coating with a protecting insect screen
and plastic spreader gearing.
• MVMO…bs K1 A – grilles made of white polymer coated aluminium.
• MVMO…bs K1 An – grilles made of anodized brushed aluminium with a protecting
insect screen and plastic spreader gearing.
• MVMO…bs K1 Ap – grilles made of polished aluminium with a protecting insect screen
and plastic spreader gearing.
• MVMO…bs K1 Zn – grilles made of galvanizes steel with a protecting insect screen and
plastic spreader gearing.
• MVMO…bs „colour code“ – colourful polymer painted models.

Overall dimensions

Dimensions D
Model [mm] Air pass [m2]

D L
L
100 MVMO bs K1 129 114 0.0051
125 MVMO bs K1 155 139 0.0083
150 MVMO bs K1 180 164 0.0118
77
160 MVMO bs K1 190 174 0.0133
200 MVMO bs K1 229 211 0.0206

Spacer mechanism for mounting Colour modifications

white brown blue beige grey black


RAL 9016 RAL 8017 RAL 5005 RAL 1015 RAL 7001 RAL 9005

Steel grilles with white Grilles made of white Grilles made of Grilles made of Grilles made of
polymer coating polymer coated anodized brushed polished aluminium galvanizes steel
aluminium aluminium

304 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


VENTS. Domestic ventilation. Catalogue №6 | 02-2020 305
FLEXIBLE AIR DUCTS
FOR VENTILATION
AND AIR CONDITIONING

Non-insulated air ducts


Polyvent 605 series page

Aluminium foil 316

Insulated air ducts


Isovent 605 series page

Aluminium foil 317

Non-insulated air ducts


Polyvent N series page

metalized foil 318

Insulated air ducts


Isovent N page

metalized foil 319

Non-insulated air ducts


Polyvent 660 series page

polyvinylchloride [65 μm] 320

Non-insulated air ducts


Polyvent 661 series page

polyvinylchloride [110 μm] 321

Non-insulated air ducts


Polyvent 606 series page

polyvinylchloride [250 μm] 322

Non-insulated air ducts


Polyvent 607 series page

polyvinylchloride [700 μm] 323

306 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Non-insulated air ducts
Polyvent 600 series page

polyether fiber covered with polyvinylchloride [250 μm] 324

Non-insulated air ducts


Polyvent 601 page

polyether fiber covered with polyvinylchloride [250 μm] 325

Non-insulated air ducts


Polyvent 620 series page

custom-designed polyurethane [250 μm] 326

Non-insulated air ducts


Polyvent 621 series page

specially designed polyurethane [450 μm] 327

Non-insulated air ducts


Polyvent 665 Comby series page

Aluminium foil and PVC 328

Non-insulated air ducts


Polyvent 615 series page

polyethylene [75 μm / 150 μm] 329

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 307


What is a flexible air duct? VENTS air duct design

Flexible air ducts, Polyvent and Isovent series are the air ducts with a frame made The Polyvent and Isovent air ducts’ frame is made of high-carbon steel spiral wire
of spiral wire reinforcement with elastic covering. Semi-flexible air ducts Aluvent with 0.8-2 mm diameter that is covered by a film of various materials.
and Thermovent are the spirally wound air ducts made of durable and less elas- The spiral wire must have corrosion-resistant material and be thoroughly
tic materials. checked to ensure its durability and defeat resistance.
The flexible and semi-flexible air duct design allows easy transportation to The distance between spiral turns is selected to ensure the air duct flexi­bility,
the site in compressed condition whereas during mounting the air ducts is to preserve its shape, comply with aerodynamic characteristics and to bear the
stretched up to required length. construction load.
The Polyvent series air ducts are available in round and rectangular mo­
difications and manifold standard sizes to meet all the mounting require-
ments.
The Aluvent and Thermovent air ducts are the spirally wound air ducts with a
specially designed tight locks that provide impervious seam and complete air
tightness.
The covering materials are selected to suit required applications and differ in
thickness, durability and chemical composition. So the required air duct type is
determined by a specific environment and purpose.

Due to many advantages flexible and semi-flexible air ducts gain more and more
popularity. Environmental protection

VENTS Company keeps a watchful eye on the ecological compatibility of the


Basic advantages: production process and applied materials. The use of the up-to-date technolo-
gies allows the VENTS air ducts comply with the highest ecology standards and
• Compact transportation; be classified as non-toxic. These air ducts produce no harmful substances emis-
• Low cost and easy weight of the system; sion and not harmful.
• Less time for mounting of the system;
• Quick system geometry amendment whenever required;
• Easy to use for dismantling, service and repair works; Fire resistance
• Cost reduction for the project.
Polyvent 605, Isovent 605, Polyvent 665 COMBY, Aluvent, Thermovent are used
for objects with special fire-resistance requirements to air ducts.
Air duct application Flexible air ducts Polyvent 605, Isovent 605, Polyvent 665 COMBY have M0 and
M1 fire protection class according to European fire standards.
Flexible and semi-flexible air ducts are used for transportation of air masses in The air ducts are available on two modifications: M0 for short-time resistance
ventilation, air heating and conditioning systems and for the technological pur- up to +250°C for and M1 for short-time resistance up to +150°C.
poses as air supply to industrial units, technological waste aspiration and trans- Semi-flexible air ducts have higher fire resistance rating: Aluvent series up to
portation of granular and granulated materials in pneumatic systems, etc. +250°C, Isovent series up to +800°C.
The air ducts are installed in ventilation systems and vents of high-rise build-
ings, cottages and residential houses.
In commercial and industrial objects the air duct are used for air conditioning Sound- and thermal insulation
systems, air supply and exhaust systems, air heating systems.
A wide range of the VENTS air ducts offers the best suitable air duct type not Isovent series insulated air ducts are the flexible air ducts covered with miner-
only for ventilation, air conditioning and air heating systems but for specially al wool and outer sleeve. Such design meets the strictest sound- and thermal
designed industrial application: insulation requirements and prevents condensate generation, minimizes heat
• Chemistry: aggressive media transportation. and cold losses, decreases noise level.
• Pharmaceutics: technological processes including pneumatic transporta- Mineral wool layer with 25 mm thickness is used for high operating conditions.
tion. This material is environmentally safe and has perfect insulating characteristics.
• Food and beverage: transportation of food products and waste within
permissible limits. Depending on required insulation type the air ducts are available in two insu-
• Car service centres, filling stations, oil refineries: gas mixture exhaust. lation modifications:
• Woodwork: transportation of saw-dust and woodwork waste. • ISO – thermal insulation;
• Glass industry: aspiration of dust, glass and ceramic particles. • SONO – sound-insulation.
Use Tables 1, 2 and 3 to select air duct type.

308 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Table 1. Air ducts characteristics
Aspiration Aspiration
of chemical of abrasive
Temperature
Series Material vapours and and Application
mode, °C
aggressive powdered
substances particles

-30 ... +250 Residential and industrial ventilation, air conditioning


Flexible non-insulated
(for M0) and heating systems, peripheral sections of large cen-
aluminium foil air ducts
Polyvent 605 + - tral utility systems with the maximum pressure 3000
with steel wire frame -30 ... +150 Pa and special fire-resistance requirements to air ducts
(for M1) (M0 or M1 models).

Residential and industrial ventilation, air conditioning and


heating systems, peripheral sections of large central utility
Flexible aluminium foil heat- -30 ... +250 systems with the maximum pressure 3000 Pa and special
insulated air ducts (for M0) fire-resistance requirements to air ducts (M0 or M1 mod-
Isovent 605 ISO – thermal insulation; + -
-30 ... +150 els). Especially suitable for applications with requirements
SONO – sound-insulation.
(for M1) to thermal insulation (Iso series) or sound insulation (Sono
series) to prevent condensate ge­neration, heat and cold
losses and noise level decrease.

Residential and industrial ventilation, heating and air


Flexible non-insulated air conditioning systems with no special requirements to
ducts with steel wire frame the combustibility and temperature resistance, in heat
Polyvent N -30...+120 + -
covered with metalized poly- accumulation units and peripheral sections of  large
ester film (45 µm) central utility systems with the maximum pressure
3000 Pa.

Residential and industrial ventilation, air condition-


Flexible insulated air ducts ing and heating systems with special flammabili-
with steel wire frame covered ty and temperature resisting requirements, in partic-
with metalized polyester film ular for applications with the need of heat insulation
Isovent N -30...+120 + -
(45 µm) combined with flexible air ducts to prevent conden-
ISO – thermal insulation; sate generation and heat and cold losses as well as in
SONO – sound-insulation. peripheral sections of large central utility systems with
the maximum pressure 3000 Pa.

Flexible PVC film non-insulated


Polyvent 660 air ducts with steel wire frame -18...+70 - - Residential and commercial ventilation systems.
(65 μm)

Flexible PVC film non-insulated


Polyvent 661 air ducts with steel wire frame -18...+70 - - Residential and commercial ventilation systems.
(110 μm)

Residential, commercial and industrial ventilation


Flexible non-insulated PVC film and air conditioning systems operating in heavy-duty
Polyvent 606 air ducts with steel wire frame -18...+90 - + mode for humid air removal, removal of smoke, post-
(250 μm) welding gases, powdered solid particles, waste chips,
fibres, vapours, soot and low-abrasive materials.

Industrial ventilation systems operating in heavy-duty


Flexible non-insulated PVC
mode for humid air removal, removal of smoke, post-
Polyvent 607 film air ducts with steel -18...+90 + +
welding gases, powdered solid particles, waste chips,
wire frame (700 μm)
fibres, vapours, soot and abrasive materials.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 309


Table 1 (continued)

Aspiration Aspiration
of chemical of abrasive
Temperature
Series Material vapours and and Application
mode, °C
aggressive powdered
substances particles

Industrial ventilation systems operating in heavy-duty


mode, incl. agricultural and pharmaceutical applica-
Flexible non-insulated air
tions for aspiration of granulated material, removal of
ducts with steel wire frame
Polyvent 600 -21...+110 + + chemical vapours, smoke, postwelding gases, pow-
made of PVC-coated polyester
dered solid particles, waste chips, fibres, vapours, soot
fabric (250 μm)
and low-abrasive dust and in environment with special
temperature resistance requirements (up to +110 °C).

Industrial ventilation systems operating in heavy-du-


ty mode, incl. agricultural and pharmaceutical applica-
Flexible non-insulated air tions for aspiration of granular and granulated mate-
ducts with steel wire frame rial, removal of chemical vapours, smoke, postwelding
Polyvent 601 -21...+110 + +
made of PVC-coated polyester gases, powdered solid particles, waste chips, fibres, va-
fabric (250 μm) pours, soot and low-abrasive dust and in environment
with special temperature resistance requirements (up
to +110 °C).

Industrial ventilation systems, the ideal solution for ap-


Flexible polyurethane non-in- plication in woodwork and timber industry, car service
Polyvent 620 sulated air ducts with steel -21...+110 + + and fuel stations, oil refineries. Used for removal of gas
wire frame (250 μm) mixture with high abrasive dust content. Suitable for
outside installation.

Industrial ventilation systems, the ideal solution for ap-


Flexible polyurethane non-in- plication in woodwork and timber industry, car service
Polyvent 621 sulated air ducts with steel -21...+110 + + and fuel stations, oil refine­ries. Used for removal of gas
wire frame (450 μm) mixture with high abrasive dust content. Suitable for
outside installation.

Flexible non-insulated air -30 ... +250


Polyvent 665 ducts with steel wire frame (for M0) Residential ventilation and air conditioning systems of
+ -
Comby covered with aluminium foil -30 ... +150 living quarters, administrative and public premises.
and polyether (for M1)

Flexible polyurethane non-in- Residential ventilation systems. Recommended for


Polyvent 615 sulated air ducts with steel -18...+70 - - ventilation of child care centres, educational and me-
wire frame (150 μm) dial facilities, spa resorts.

310 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Aspiration Aspiration
of chemical of abrasive
Temperature
Series Material vapours and and Application
mode, °C
aggressive powdered
substances particles

Residential and industrial ventilation, air condition-


Semi-flexible aluminium air
Aluvent -30…+ 250 + + ing and heating systems with the maximum pressure
ducts (50 μm, 80 μm, 100 μm)
10 000 Pa.

Residential and industrial ventilation, air condition-


Semi-flexible galvanized or
ing and heating systems with the maximum pressure
Thermovent stainless steel air ducts (80 μm, -30…+700 + +
10 000 Pa for hot air removal from boiler houses and
100 μm)
smoke exhaust systems.

Residential and industrial ventilation, air condition-


Stainless steel air ducts with
Thermovent ing and heating systems with the maximum pressure
high temperature resistance -30…+800 + +
Aero 10 000 Pa for hot air removal from boiler houses and
(100 μm)
smoke exhaust systems.

Semi-flexible corrugated stain- Residential and industrial ventilation, air condition-


less steel air ducts with high ing and heating systems with the maximum pressure
Thermovent Flex -30…+800 + +
temperature resistance (100 10 000 Pa for hot air removal from boiler houses and
μm) smoke exhaust systems.

Double-layer stainless steel Residential and industrial ventilation, air condition-


Thermovent air ducts with smooth internal ing and heating systems with the maximum pressure
-30…+800 + +
Aero Flex surface and corrugated exter- 10 000 Pa for hot air removal from boiler houses and
nal layer smoke exhaust systems.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 311


Table 2. Chemical resistance
of flexible and semi-flexible Aluvent air ducts

660, 661,
Air duct type 615, 6150 606, 6061 600, 601 620, 6201, 621 Aluvent
602, 607

DDT-kerosene X A A A A A

Skydrol-oil for hydraulic systems X 0 0 0 0 0

Nitric acid 10 % A A A A A A

Amyl alcohol A A A A A A

Ammonium hydrate A A A A A A

Acetylene 0 0 0 0 0 A

Acetone A X X X 0 A

Benzene X X X X 0 B

Potassium bicarbonate A A A A A A

Butyl alcohol X A A A A A

Butyl ether 0 A A A A 0

Vinyl chloride (monomer) X X X X 0 0

Glycerine A C C C C A

Tannic acid A A A A A A

Potassium carbonate A A A A A X

Sodium carbonate A A A A A A

Xylene X X 0 0 0 A

Hydraulic oil 0 0 0 0 C 0

Methyl alcohol A A A A A A

Formic acid B 0 0 0 C B

Nitrobenzene X X X X 0 A

Ozone X A A A A B

Hydrogen peroxide B A A A A A

Perchloroethylene X 0 0 0 0 B

Sodium chloride A A A A A B

Natural gas dry A A A A A B

Propane (gas) A A A A A A

Sulphuric acid 10 % A A A A A B

Hydrogen sulfide, wet A 0 0 0 0 A

Hydrogen sulfide, dry A 0 0 0 0 A

Esters (non-flammable) 0 0 0 0 0 0

Hydrochloric acid 15 % A A A A A 0

Spirits 0 C C C B 0

Toluene X X X X 0 A

Jet oil JP-1 X A A A A 0

Trichloroethylene (tri) X 0 0 0 0 C

312 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Heavy-flammable N N J J J J

Carbon monoxide A 0 0 0 0 A

Carbon dioxide A A A A A A

Carbonic acid A A A A A A

Pheron 12 0 B B B B 0

Ammonium phosphate 0 A A A A B

Sodium phosphate A A A A A A

Phosphoric acid 50 % A A A A A B

Chlorine dry X 0 0 0 0 B

Potassium chlorate A A A A 0 A

Aluminium chloride A A A A A B

Ammonium chloride A A A A A A

Ferric chloride A 0 0 0 0 X

Antimonous chloride 50 % A 0 0 0 0 B

Zinc chloride A A A A A C

Ethylic alcohol A A A A A 0

A – High resistance B – Medium resistance C – Relative resistance X – No resistance


0 – No data J – Heavy flammable (Yes) N – Not flammable (No)

Table 3. Chemical resistance of semi-flexible Thermovent air ducts

Air duct type

Thermovent, Thermovent Aero, Thermovent Flex, Thermovent Aero Flex

Ammonium hydroxide Resistant

Nitric acid Up to 30 %, 100°C

Barium chloride, dehydrate Up to 20 %, 100° C

Isopropyl alcohol Resistant

Hydrochloric acid Up to 1 %, 50°C

Potassium chromate Resistant

Potassium bichromate Resistant

Potassium hydroxide Up to 50 %, 20°C

Fuel oil Resistant

Caustic soda Up to 40 %, 90°C

Sulphuric acid Up to 3 %, 50°C

Toluene Resistant

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 313


Air duct mounting Air duct cutting

Correct air duct connection is of significant importance to ensure reliable oper- • Calculate the air duct length in such a way as to omit any sagging as mount-
ation and aerodynamic characteristics of mounted air ducts. ed.
Flexible air ducts are connected to basic ventilation system components by • Stretch the air duct to its maximum.
various fittings or connected directly to final components as ventilation grilles, • Measure the required length and mark it.
disk valves and fans. • For non-insulated air ducts: cut air duct along a spiral turn with a sharp knife
A wide range of VENTS fittings is designed to consider variety of manifold air or scissors and cut the wire with cutting pliers.
duct connections and facilitate mounting works a lot. • For insulated air ducts: first cut the outer sleeve with scissors. Use gloves
for that.

Tools and materials for air duct mounting


Connection to final component
• Construction meter
• Marker • Connect the air duct to the ventilation grille flange or fan branch pipe with
• Cutting knife respect to the spiral air motion.
• Flat-nose pliers or cutting pliers • Fix it with clamps. Use respective diameter clamps. Make sure that the air
• Gloves (for work with insulated air ducts) duct is not deformed in the attaching points.
• Cross-point screwdriver for clamp fixing
• Mounting tape
• Fixing clamps Mounting with fittings

• Connect the air duct to a fitting by spiral turns, the branch pipe length for
General rules connection to the air duct must be at least 50 mm. Seal the joint with a mount-
ing tape if required.
• Mounted air duct must be stretched to the maximum to avoid pressure loss • Fix it with a fixing clamp.
• Air duct must not be deflected and sagged.
• Keep bend radius as large as possible because the minimum air bend in-
creases pressure drop. To level up this effect the bend radius must be equal to Mounting of non-insulated air ducts
the double air duct diameter.
• Provide grounding during mounting operations as static electricity can be • Cover the branch pipe with the air duct at least by 50 mm by spiral turnings
accumulated during transportation of air containing organic solvents along the over the air duct. Seal the joint with a mounting tape if required.
air ducts. • Fix the air duct with a fixing clamp.
• Air flow in the air duct must have spiral motion.
• Use metal connectors or reducers in case of layout through wall construc-
tions.
• Take precautions not to deform or damage air duct during mounting.
Warning! To avoid deformation stretch Aluvent air ducts gradually from the
middle to the ends.

 

 

314 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Mounting of insulated air duct

 Cover the branch pipe with the air duct at least by 50 mm by spiral turn-
ings over the air duct.
 Pull off the insulation material. Seal the joint with a mounting tape if re-
quired.
 Fix the air duct with a fixing clamp.
fig. 1 a fig. 1 b
 Pull away the insulation material.
• Fix the outer shell with a mounting tape by wrapping it twice around
the air duct.

 
fig. 1 c fig. 1 d

Air duct application and use recommendations

• Flexible air ducts are not recommended for use in vertical shafts above
2 floors high.
  • In case of application of the flexible air duct in high temperature operat-
ing conditions make sure that the air duct temperature resistance is suitable
for the specific operating conditions.
• During installation in fireproof constructions of the floors/ceilings the air
Suspension points ducts must comply with fire safety requirements.
• Flexible air ducts are not suitable for routing through the floor or below
• Maximum sagging of the air duct between two suspension points must ground. Contact with ground is not allowed.
not exceed 50 mm/m (fig. 1 a). • Use only specially designed air ducts for external mounting.
• Distance between two suspension points ranges between 1.5 to 3 m de- • Air ducts must be mounted far away enough from the places with exces-
pending on the air duct type (fig. 1 b). sive heat generation.
• Effective span distance for the flexible air duct must be 1 meter (fig. 1 b). • Application scope of flexible air ducts can be limited by national norms
• In case of vertical air duct layout the distance between the fixing clamps and standards. Read information on air duct application and technical data
shall be from 1 m to 1.8 m (fig. 1 d). before using the air ducts!

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 315


FLEXIBLE AIR DUCTS POLYVENT

Polyvent 605 Description • High rupture and mechanical resisting fea-


tures.
series • Flexible air duct from aluminium foil laminat-
ed with polyether. Recommended application
• Spiral frame from high-carbon steel wire. • Applied in residential and industrial ventila-
tion, air conditioning and heating systems, pe-
Features ripheral sections of large central utility systems
with the maximum pressure 3000 Pa and special
• Pollution-free, no harmful substances emis- fire-resistance requirements to air ducts (M0 or M1
sion during operation. models).
• No chlorine and cadmium content. • Recommended for ventilation of child care
• high elasticity and temperature resistance: centres, educational and medial facilities, spa re-
605 M0 short-time resistance up to +250°C for M0, short- sorts.
tome resistance up to +150°C for M1.
605 M1

Technical data

Item 605 M0, 605 M1 6051 M0, 6051 M1

Range of sizes [mm] Ø 102; 127; 152; 182; 203; 254; 315 110x54; 60x204
Air duct base Aluminium foil laminated with polyester film
Air duct wire steel spring, 0.8-1.5 mm thick
6051 M0 Safety class incombustible (for M0 model), self-extinguishing (for M1 model)
6051 M1 Operating temperature
-30 ... +250 (for M0 model), -30 ... +150 (for M1 model)
range [°C]
Standard length [m] 10
Available lengths
1; 1.5; 2.5; 3; 6 7.6; 10
(cutting) [m]
Flexible non-insulated aluminium foil Air speed [m/s] 30
air ducts with steel wire frame
Maximum operating
3000
pressure [Pa]

Colour range

Aluminium Brown
(_) (B)

Packing

Cardboard Unit coloured Net


box packing

Order code

Polyvent Series type / Ø / length - colour

605 M0 _ – Aluminium
6051 M1 B – brown

Accessories
Backdraft
Diffusers and air disk valves Grilles and hoods dampers Fittings Clamps

316 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


FLEXIBLE AIR DUCTS ISOVENT

Isovent 605 Description • Applied in residential and industrial venti-


lation, air conditioning and heating systems,
series • Flexible heat-insulated (Iso) and insula­ted- peripheral sections of large central utility sys-
absorbing (Sono) air duct. tems with the maximum pressure 3000 Pa and
• Spiral frame from high-carbon steel wire. special fire-resistance requirements to air ducts
(M0 or M1 models).
Features • Especially suitable for application with re-
quirements to thermal insulation (Iso series) or
• Pollution-free, no harmful substances emis- sound insulation (Sono series) to prevent con-
sion during operation. densate generation, heat and cold losses and
• No chlorine and cadmium content. noise level decrease.
• High elasticity and temperature resistance: • Recommended for ventilation of child care
centres, educational and medial facilities, spa
605-Iso M0 short-time resistance up to +250°C for M0,
short-tome resistance up to +150°C for M1. resorts.
605-Iso M1 • High rupture and mechanical resisting fea-
tures.

Flexible aluminium foil Recommended application


heat-insulated air ducts
Technical data

605-Iso M0 605-Sono M0
Item
605-Iso M1 605-Sono M1
Range of sizes [mm] Ø 102; 127; 152; 182; 203; 254; 315
Aluminium foil microperforated aluminium band
Air duct base
laminated with polyester film laminated with polyester film
Air duct wire steel spring, 0.8-1.5 mm thick
Insulation mineral wool, 25 mm

605-Sono M0 Outer sleeve Aluminium foil laminated with polyester film


Safety class incombustible (for M0 model), self-extinguishing (for M1 model)
605-Sono M1 Operating temperature
-30 ... +250 (for M0 model), -30 ... +150 (for M1 model)
range [°C]
Flexible heat-
Standard length [m] 10
and sound-insulated
aluminium foil air ducts Available lengths (cut-
7.6; 10
ting) [m]
Air speed [m/s] 30
Maximum operating
3000
pressure [Pa]

Colour range

Aluminium Brown
(_) (B)

Packing

Cardboard
box
Order code

Isovent 605 - type class / Ø / Length - colour

Iso M0 _ – Aluminium
Sono M1 B – brown

Accessories
Backdraft
Diffusers and air disk valves Grilles and hoods dampers Fittings Clamps

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 317


FLEXIBLE AIR DUCTS POLYVENT

Polyvent N Description short-time resistance up to +120°C.

series • Flexible air duct from metalized polyester Recommended application


film.
• Applied in residential and industrial ventila-
• Spiral frame from high-carbon steel wire. tion, heating and air conditioning systems with
no special requirements to the combustibility
Features and temperature resistance, in heat accumulation
units and peripheral sections of large cent­ral util-
• Pollution-free flexible non-insulated air duct. ity systems with the maximum pressure 3000 Pa.
No harmful substances emission during opera-
tion. • Recommended for ventilation of child care
centres, educational and medial facilities, spa re-
• high elasticity and temperature resistance: sorts.

Technical data

Flexible non-insulated air ducts Item Polyvent N


with steel wire frame covered
with metalized polyester film Range of sizes [mm] Ø 82; 102; 127; 152; 182; 203; 254; 315; ...630
Air duct base metalized polyester film (45 μm)
Air duct wire steel spring, 0.8-1.5 mm thick
Operating temperature
-30...+120
range [°C]
Standard length [m] 1; 1.5; 3; 7.6
Available lengths
1; 1.5; 3; 7.6
(cutting) [m]
Air speed [m/s] 30
Maximum operating
3000
pressure [Pa]

Colour range

Aluminium
(_)

Packing

Cardboard Unit coloured Net


box packing

Order code

Polyvent N Ø / length

Accessories
Backdraft
Diffusers and air disk valves Grilles and hoods dampers Fittings Clamps

318 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


FLEXIBLE AIR DUCTS ISOVENT

Isovent N Description Recommended application


series • Flexible insulated air duct from metalized • Applied in residential and industrial ventila-
polyether film. tion, air conditioning and heating systems with
special flammability and temperature resis­ting
• Spiral frame from high-carbon steel wire. requirements, in particular for application with
the need of heat insulation combined with flex-
Features ible air ducts to prevent condensate gene­ration
and heat and cold losses as well as in peripheral
• Pollution-free flexible air duct insulated with sections of large central utility systems with the
mineral wool layer.
maximum pressure 3000 Pa.
• No harmful products emission during ope­ • Recommended for ventilation of child care
ration.
centres, educational and medial facilities, spa re-
• No chlorine and cadmium content. sorts.
• High elasticity and temperature resistance:
short-time resistance up to +120°C.

Technical data
Flexible insulated air ducts
with steel wire frame covered Item Isovent N
with metalized polyester film
Range of sizes [mm] Ø 82; 102; 127; 152; 162; 182; 203; 254; 315; ...630
Air duct base metalized polyester film (45 μm)
Air duct wire steel spring, 0.8-1.5 mm thick
Insulation Mineral wool, 25 mm
Outer sleeve metalized polyester film (45 μm)
Operating temperature
-30...+120
range [°C]
Standard length [m] 7.6
Available lengths
7.6
(cutting) [m]
Air speed [m/s] 30
Maximum operating
3000
pressure [Pa]

Colour range

Aluminium
(_)

Packing

Cardboard
box

Order code

Isovent N Ø / length

Accessories
Backdraft
Diffusers and air disk valves Grilles and hoods dampers Fittings Clamps

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 319


FLEXIBLE AIR DUCTS POLYVENT

Polyvent 660 Description Recommended application


series • Flexible PVC air duct with spiral high-carbon • Applied in residential and commercial ventila-
steel wire frame. tion systems.
• The ideal solution for ventilation of living
Features quarters and office premises.

• High compression ratio.


• Heavy-flammable, flame-retarding, self-extin-
guishing.

660

Technical data

Item 660 6601

Range of sizes [mm] Ø 82; 102; 127; 152 110x55; 60x204


Air duct base PVC film (65 μm)
Air duct wire steel spring, 0.8 mm thick
Operating temperature
-18...+70
6601 range [°C]
Standard length [m] 1; 1.5; 3; 6 1; 1.5; 3; 6
Available lengths 1; 1.5; 2.5; 3; 6; 15
1; 1.5; 3; 6
(cutting) [m] (only for Ø 82/102/127)
Air speed [m/s] 30
Maximum operating
Flexible PVC film 3000
pressure [Pa]
non-insulated air ducts
with steel wire frame (65 μm)

Colour range

White
(_)

Packing

Cardboard Unit coloured Net


box packing

Order code

Polyvent type size / length

660
6601

Accessories
Backdraft
Diffusers and air disk valves Grilles and hoods dampers Fittings Clamps

320 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


FLEXIBLE AIR DUCTS POLYVENT

Polyvent 661 Description Recommended application


series • Flexible PVC air duct with spiral high-­ • Applied in residential and commercial ven-
carbon steel wire frame. tilation systems.
• Recommended for use in office premises,
Features trade and recreational buildings, etc.

• Low pressure loss due to increased wall


­rigidity.
• Long service life.
• Heavy-flammable, flame-retarding, self-ex-
tinguishing.

Technical data

Flexible PVC film Item Polyvent 661


non-insulated air ducts
with steel wire frame (110 μm) Range of sizes [mm] Ø 102; 127; 152
Air duct base PVC film (110 μm)
Air duct wire steel spring, 0.8 mm thick
Operating temperature
-18...+70
range [°C]
Standard length [m] 6
Available lengths
6
(cutting) [m]
Air speed [m/s] 30
Maximum operating
3000
pressure [Pa]

Colour range

White
(_)

Packing

Cardboard Unit coloured Net


box packing

Order code

Polyvent 661 Ø / length

Accessories
Backdraft
Diffusers and air disk valves Grilles and hoods dampers Fittings Clamps

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 321


FLEXIBLE AIR DUCTS POLYVENT

Polyvent 606 Description • High mechanical and chemical resistance,


heavy-flammable, flame-retarding, self-extin­
series • Flexible PVC air duct with spiral high-­carbon guishing.
steel wire frame.
Recommended application
Features • Applied in residential, commercial and
i­ ndustrial ventilation and air conditioning ­systems
• Low pressure loss due to extremely high wall operating in heavy-duty mode.
rigidity.
• The service life is equal to that one of the gal- • Humid air removal, removal of smoke, post-
welding gases, powdered solid particles, waste
vanized air ducts.
chips, fibres, vapours, soot and low-abrasive ma-
• High abrasion resistance. terials.

606
Technical data

Item 606 6061

Ø 102; 127; 152; 182; 65x145; 65x185; 80x200, 55x110,


Range of sizes [mm] 70x150, 80x158, 58x230, 54x222,
203; 254; 304 82x222, 90x220, 80x230, 116x224
Air duct base PVC film (250 μm)
6061 Air duct wire steel spring, 0.8-1.5 mm thick
Operating temperature
-18...+90
range [°C]
Standard length [m] 6
Available lengths
6
(cutting) [m]
Flexible non-insulated Air speed [m/s] 30
PVC film air ducts Maximum operating
3000
with steel wire frame (250 μm) pressure [Pa]

Colour range

White Brown Grey


(_) (B) (G)

Packing

Cardboard Unit coloured Net


box packing

Order code

Polyvent type size / length - colour

606 _ – white
6061 B – brown
G – grey

Accessories
Backdraft
Diffusers and air disk valves Grilles and hoods dampers Fittings Clamps

322 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


FLEXIBLE AIR DUCTS POLYVENT

Polyvent 607 Description • High abrasion resistance.


• Heavy-flammable, flame-retarding, self-ex-
series • Flexible PVC air duct with spiral high-car-
tinguishing.
bon steel wire frame.
Recommended application
Features
• Applied in industrial ventilation systems op-
• Low pressure loss due to extremely high erating in heavy-duty mode.
wall rigidity. • Humid air removal, removal of smoke, post-
• The service life is equal to that one of the welding gases, powdered solid particles, waste
galvanized air ducts. chips, fibres, vapours, soot and low-abrasive ma-
terials.

Technical data

Item 607

Range of sizes [mm] Ø 102; 120 Ø 127; 152; 160; 182; 203; 254
Flexible non-insulated Air duct base PVC film (700 μm)
PVC film air ducts Air duct wire steel spring, 1.5 mm thick
with steel wire frame (700 μm) Operating temperature
-18...+90
range [°C]
Standard length [m] 6 2
Available lengths
6 2
(cutting) [m]
Air speed [m/s] 30
Maximum operating
3000
pressure [Pa]

Colour range

Grey
(_)

Packing

Cardboard Unit coloured Net


box packing

Order code

Polyvent 607 Ø / length

Accessories
Backdraft
Diffusers and air disk valves Grilles and hoods dampers Fittings Clamps

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 323


FLEXIBLE AIR DUCTS POLYVENT

Polyvent 600 Description Recommended application


series • Flexible air duct from polyester PVC impreg- • Applied in industrial ventilation systems op-
nated fiber and spiral high-carbon steel wire erating in heavy-duty mode, incl. agricultural and
frame. pharmaceutical application.
• Handling of granular and granulated material,
Features removal of chemical vapours, smoke, postwelding
gases, powdered solid particles, waste chips, fibres
• Low pressure loss due to high wall rigidity. , vapours, soot and low-abrasive dust and in en-
vironment with special temperature resistance re-
• High mechanical and abrasion resistance.
quirements (up to +110 °C).
• High chemical stability, high temperature re-
sistance (up to +110 °C).

Technical data

Item Polyvent 600

Range of sizes [mm] Ø 102; 114; 121; 127; 133; 140; 152; 165; 182; 203; 228; 254; 279; 304
Flexible non-insulated air ducts with
Air duct base polyester fiber covered with PVC (250 μm)
steel wire frame made of PVC-coated
Air duct wire steel spring, 0.8-2 mm thick
polyester fabric (250 μm)
Operating temperature
-21...+110
range [°C]
Standard length [m] 6
Available lengths
6
(cutting) [m]
Air speed [m/s] 30
Maximum operating
3000
pressure [Pa]

Colour range

White Grey Brown


(_) (G) (B)

Packing

Cardboard Unit coloured Net


box packing

Order code

Polyvent 600 Ø / length - colour

_ – white
G – grey
B – brown

Accessories
Backdraft
Diffusers and air disk valves Grilles and hoods dampers Fittings Clamps

324 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


FLEXIBLE AIR DUCTS POLYVENT

Polyvent 601 Description Recommended application


series • Flexible air duct from polyester PVC im- • Applied in industrial ventilation systems
pregnated fiber and spiral high-carbon steel ope­rating in heavy-duty mode, incl. agricultur-
wire frame. al and pharmaceutical application.
• Handling of granular and granulated mate-
Features rial, removal of chemical vapours, smoke, post-
welding gases, powdered solid particles, waste
• Low pressure loss due to high wall rigidity. chips, fibres, vapours, soot and low-abrasive
dust and in environment with special temper-
• High mechanical and abrasion resistance.
ature resistance requirements (up to +110 °C).
• High chemical stability, high temperature
­resistance (up to +110 °C).

Technical data

Flexible non-insulated air ducts with Item Polyvent 600


steel wire frame made of PVC-coated
polyester fabric (250 μm) 65x145; 65x185; 80x200; 55x110, 70x150, 80x158,
Range of sizes [mm]
58x230, 54x222, 82x222, 90x220, 80x230.116x224
Air duct base polyester fiber covered with PVC (250 μm)
Air duct wire steel spring, 0.8-2 mm thick
Operating temperature
-21...+110
range [°C]
Standard length [m] 6
Available lengths
6
(cutting) [m]
Air speed [m/s] 30
Maximum operating
3000
pressure [Pa]

Colour range

White Grey Brown


(_) (G) (B)

Packing

Cardboard Unit coloured Net


box packing

Order code

Polyvent 601 size / length - colour

_ – white
G – grey
B – brown

Accessories
Backdraft
Diffusers and air disk valves Grilles and hoods dampers Fittings Clamps

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 325


FLEXIBLE AIR DUCTS POLYVENT

Polyvent 620 Description content. High resistance to solvent-, gasoline- and


oil vapours.
series • Flexible polyurethane air duct with high-car-
• UV- and ozone resistance. Suitable for han-
bon steel wire frame.
dling of hot gases (up to +120 °C).

Features Recommended application


• Extremely high wear resistance, durability, air • Applied in industrial ventilation systems, the
tightness, low pressure losses. ideal solution for application in woodwork and
timber industry, car service and fuel stations, oil
• Heavy-flammable. The ideal solution for appli-
refineries. Used for removal of gas mixture with
cation in woodwork and timber industry and for
high abrasive dust content. Suitable for outside
removal of air mixtures with high abrasive dust
installation.

620

Technical data

Item 620 6201

224x116, 230x80, 220x90,


Ø 102; 121; 127; 152; 165;
Range of sizes [mm] 222x54, 230x58, 150x80,
6201 182; 203; 228; 254; 304
150x70, 110x54, 145x65
Air duct base Specially designed polyurethane film (250 μm)
Air duct wire steel spring, 0.8-2 mm thick
Operating temperature
-21...+110
range [°C]
Standard length [m] 6
Flexible polyurethane Available lengths
6
non-insulated air ducts (cutting) [m]
with steel wire frame (250 μm) Air speed [m/s] 30
Maximum operating
3000
pressure [Pa]

Colour range

Transparent
(_)

Packing

Cardboard Unit coloured Net


box packing

Order code

Polyvent type size / length

620
6201

Accessories
Backdraft
Diffusers and air disk valves Grilles and hoods dampers Fittings Clamps

326 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


FLEXIBLE AIR DUCTS POLYVENT

Polyvent 621 Description • UV- and ozone resistance.


• Hot gases handling is possible (up to
series • Flexible polyurethane air duct with high-­ +120°C).
carbon steel wire frame.
Recommended application
Features
• Applied in industrial ventilation systems,
• High flexibility, wear resistance, durability, air the ideal solution for application in woodwork
tightness, extremely low pressure losses. and timber industry, car service and fuel sta-
tions, oil refineries. Used for removal of gas mix-
• Heavy flammable.
ture with high abrasive dust content. Suitable
• High solvent-, gasoline- and oil vapours for outside installation.
­resistance.

Technical data

Item Polyvent 621

Flexible polyurethane Range of sizes [mm] Ø 102; 114; 121; 127; 133; 140; 152; 165; 182; 203; 228; 254; 304
non-insulated air ducts Air duct base Specially designed polyurethane film (450 μm)
with steel wire frame (450 μm) Air duct wire spring steel 0.8-2 mm thick
Operating temperature
-21...+110
range [°C]
Standard length [m] 6
Available lengths
6
(cutting) [m]
Air speed [m/s] 30
Maximum operating
3000
pressure [Pa]

Colour range

Transparent
(_)

Packing

Cardboard Unit coloured Net


box packing

Order code

Polyvent 621 Ø / length

Accessories
Backdraft
Diffusers and air disk valves Grilles and hoods dampers Fittings Clamps

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 327


FLEXIBLE AIR DUCTS POLYVENT

Polyvent 665-Comby Description Versus aluminium foil air ducts:


• High rupture resistance;
series • Flexible heavy-duty air duct from multilayer al-
• better protection against outside mechanical
uminium foil, polyether and PVC with high-carbon
steel wire frame. impact;
• airtight, expansion- and deformation resist-
Features ing.

Versus PVC foil air ducts: Recommended application


• High temperature resistance; • Applied in residential ventilation and air con-
• non-flammable internal layer, fire safety class ditioning systems of living quarters, administra-
M0 (up to 250 °C) or M1 (up to 150 °C). tive and public premises.

Technical data

Flexible non-insulated air ducts with Item Polyvent 665-Comby


steel wire frame covered
with aluminium foil and polyether Range of sizes [mm] Ø 102.127; 152;
Aluminium foil laminated with polyester film
Air duct, internal layer
incombustible (for M0 model), self-extinguishing (for M1 model)
Air duct, external layer PVC
Air duct wire steel spring, 0.8-2 mm thick
Operating temperature
-30 ... +250 (for M0), -30 ... +150 (for M1)
range [°C]
Standard length [m] 1; 1.5; 2; 2.5; 3; 6; 10
Available lengths
1; 1.5; 2; 2.5; 3; 6; 10
(cutting) [m]
Air speed [m/s] 30
Maximum operating
3000
pressure [Pa]

Colour range

White
(_)

Packing

Cardboard Unit coloured Net


box packing

Order code

Polyvent 665 – Comby fire safety class Ø / length

M0
M1

Accessories
Backdraft
Diffusers and air disk valves Grilles and hoods dampers Fittings Clamps

328 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


FLEXIBLE AIR DUCTS POLYVENT

Polyvent 615 Description Recommended application


series • Flexible air duct from polyethylene with • Applied in residential ventilation systems.
high-carbon steel wire frame. • Recommended for ventilation of child care
centres, educational and medial facilities, spa
Features resorts.

• Pollution-free, no harmful substances emis-


sion during operation.
• Contents no chlorine and cadmium.

Technical data
615
Item 615 6150

Range of sizes [mm] Ø 102; 127; 152; 182 55x110; 70x150; 80x150; 54x222
Air duct base Polyethylene film ( 150 μm) Polyethylene film (150 μm)
Air duct wire steel spring, 0.8 mm thick
Operating temperature
-18...+70
range [°C]
Standard length [m] 6
Available lengths
6
(cutting) [m]
Air speed [m/s] 30
6150 Maximum operating
3000
pressure [Pa]

Flexible polyurethane
non-insulated air ducts
with steel wire frame
(75 and 150 μm)

Colour range

White
(_)

Packing

Cardboard Unit coloured Net


box packing

Order code

Polyvent type size / length

615
6150

Accessories
Backdraft
Diffusers and air disk valves Grilles and hoods dampers Fittings Clamps

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 329


FLEXIBLE AIR DUCTS POLYVENT

Pressure loss diagram per 1 m stretched air duct

Calculation example

• Select a curve that matches the air duct diameter [mm], 200 mm
in this case.
• Find the intersection point of this line with the vertical line of
the required air flow in m3/h, 500 m3/h in this case.
• The horizontal line that shows the pressure loss in Pa per 1 m
straight air duct crosses this intersection point.
• Multiply pressure loss value (2.4 Pa/m at 20°C) by total air duct
length to get the total pressure loss value. To calculate pressure loss
in case of bends consider each bend as extra air duct meter.

330 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


VENTS. Domestic ventilation. Catalogue №6 | 02-2020 331
AIR DUCTS FOR VENTILATION, HEATING
AND AIR CONDITIONING

332 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Non-insulated air ducts
Aluvent series page

Aluminium foil 334

Non-insulated air ducts


Thermovent series page

galvanized and stainless steel 335

Non-insulated air ducts


Thermovent Aero series page

stainless steel 336

Non-insulated air ducts


Thermovent Flex series page

stainless steel 337

Non-insulated air ducts


Thermovent Aero Flex series page

stainless steel 338

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 333


FLEXIBLE AIR DUCTS ALUVENT

Aluvent Description • Low dynamic losses.


• Low weight, high elasticity and easy mount-
series • Flexible spiral seam aluminium band air ducts ing.
with high aerodynamic and strength characteris-
tics.
Recommended application
Features • Applied in residential and industrial ventilation, air
conditioning and heating systems with the maximum
• Made of incombustible, corrosion-resisting al- pressure 10 000 Pa.
uminium band. • For supply and exhaust ventilation.
• Specially designed high-quality locks ensure
high seam tightness and total air tightness of the
ducts.

Technical data

Semi-flexible aluminium Item Aluvent M Aluvent N Aluvent S Aluvent D


air ducts
Diameter range [mm] 80/100/110/120/125/130/140/150/160/180/200/250/315
Material Aluminium
Number of layers 1 1 1 2
Total thickness [μm] 50 80 100 2x50
Operating temperature
-30…+ 250
range [°C]
Maximum
30
air speed [m/s]
Maximum
8 000 10 000 10 000 10 000
operating pressure [Pa]
Minimum
0.7xD 0.73xD 0.76xD 0.85xD
bend radius [mm]
Length [m] 1; 2; 2.5; 3; 6

Packing

Polyethylene Cardboard
Thermal packing
bag box

Order code

Aluvent type Ø / length

M
N
S
D

Accessories
Backdraft
Diffusers and air disk valves Grilles and hoods dampers Fittings Clamps

334 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


FLEXIBLE AIR DUCTS THERMOVENT

Thermovent Description • Low weight and easy mounting.

series • Semi-flexible stainless or galvanized steel Recommended application


spiral seam air ducts with high aerodynamic
and strength characteristics. • Applied in residential and industrial ventila-
tion, air conditioning and heating systems with
the maximum pressure 10 000 Pa.
Features
• For supply and exhaust ventilation.
• Made of incombustible, corrosion-resisting • Applied in the systems of hot air remov-
stainless steel or galvanized steel band. al from boiler houses and smoke exhaust sys-
• Increased thermal resistance (up to 700°C). tems.
• Superdense high-quality triple locks ensure
high seam tightness and total air tightness of
the ducts.
• Low dynamic losses.

Technical data

Item Thermovent N Thermovent S Thermovent N, Zn

Diameter range [mm] 80/100/110/120/125/130/140/150/160/180/200/250/315


Material Stainless steel Stainless steel Galvanized steel
Number of layers 1 1 1
Semi-flexible galvanized Total thickness [μm] 80 100 80
or stainless steel air ducts
Operating temperature
-30…+700 -30…+700 -30…+700
range [°C]
Maximum
30 30 30
air speed [m/s]
Maximum
10 000 10 000 10 000
operating pressure [Pa]
Minimum bend
3xD 3xD 3xD
radius [mm]
Length [m] 1; 2; 3; 6 1; 2; 3; 6 1; 2; 3; 6

Packing

Cardboard
box

Order code

Thermovent type Ø / length material

N _ – by default
S Stainless steel
Zn – galvanized steel

Accessories
Backdraft
Diffusers and air disk valves Grilles and hoods dampers Fittings Clamps

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 335


FLEXIBLE AIR DUCTS THERMOVENT

Thermovent Aero Description • Smooth internal surface ensures low dynam-


ic losses.
series • Spiral seam stainless steel air ducts with high • Low weight and easy mounting.
aerodynamic and strength characteristics.
Recommended application
Features
• Applied in residential and industrial ventila-
• Made of incombustible corrosion-resisting tion, air conditioning and heating systems with
stainless steel band. the maximum pressure 10 000 Pa.
• Increased thermal resistance (up to 800°C). • For supply and exhaust ventilation.
• Specially designed high-quality locks ensure • Applied in the systems of hot air removal from
high seam tightness and total air tightness of the boiler houses and smoke exhaust systems.
ducts.

Technical data
Stainless steel air ducts
with high temperature resistance Item Thermovent Aero

80/100/110/120/125/130/135/140/150/160
Diameter range [mm]
/180/200/250/300/350/400
Material Stainless steel
Number of layers 1
Total thickness [μm] 100
Operating temperature
-30…+800
range [°C]
Maximum air speed [m/s] 30
Maximum operating
10 000
pressure [Pa]
Minimum bend radius [mm] 4xD (up to 200 mm diameter) and 4.5D (above 200 mm)
Length [m] 1; 2; 3; 6

Packing

Cardboard
box

Order code

Thermovent Aero Ø / length

Accessories
Backdraft
Diffusers and air disk valves Grilles and hoods dampers Fittings Clamps

336 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


FLEXIBLE AIR DUCTS THERMOVENT

Thermovent Flex Description namic losses.


• Low weight and easy mounting.
series • Spiral seam stainless steel air ducts with high
aerodynamic and strength characteristics.
Recommended application
Features • Applied in residential and industrial ventila-
tion, air conditioning and heating systems with
• Made of incombustible corrosion-resisting the maximum pressure 10 000 Pa.
stainless steel band. • For supply and exhaust ventilation.
• Increased thermal resistance (up to 800°C). • Applied in the systems of hot air remo­val
• Specially designed high-quality locks en- from boiler houses and smoke exhaust sys-
sure high seam tightness and total air tightness tems.
of the ducts.
• Smooth internal surface ensures low dy-

Technical data

Semi-flexible stainless steel air ducts Item Thermovent Flex


with high temperature resistance
50/60/80/100/110/120/125/130/135/140
Diameter range [mm]
/150/160/180/200/250/300/350/400
Material Stainless steel
Number of layers 2
Total thickness [μm] 100
Operating temperature
-30…+800
range [°C]
Maximum air speed [m/s] 30
Maximum operating
10 000
pressure [Pa]
up to
Minimum 4D
Ø 200 mm
bend radius
[mm] above
4.5xD
Ø 200 mm
Length [m] 1; 2; 3; 6

Packing

Cardboard
box

Order code

Thermovent Flex Ø / length

Accessories
Backdraft
Diffusers and air disk valves Grilles and hoods dampers Fittings Clamps

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 337


FLEXIBLE AIR DUCTS THERMOVENT

Thermovent Aero Flex Description ducts.


• Smooth internal surface ensures low dynam-
series • Double-layer stainless steel spiral-seam air ic losses.
ducts with high aerodynamic and strength char-
acteristics. • Low weight and easy mounting.

Recommended application
Features
• Applied in residential and industrial ventila-
• Made of incombustible corrosion-resisting tion, air conditioning and heating systems with
stainless steel band. the maximum pressure 10 000 Pa.
• Increased thermal resistance (up to 800°C). • For supply and exhaust ventilation.
• Specially designed high-quality locks ensure • Applied in the systems of hot air remo­val from
high seam tightness and total air tightness of the boiler houses and smoke exhaust systems.

Technical data
Double-layer stainless steel air ducts
with high temperature resistance Item Thermovent Aero Flex

50/60/80/100/110/120/125/130/135/140
Diameter range [mm]
/150/160/180/200/250/300/350/400
Material Stainless steel
Number of layers 2
Internal
Total 100
layer
thickness
[μm] External
100
layer
Operating temperature
-30…+800
range [°C]
Maximum air speed [m/s] 30
Maximum operating
10 000
pressure [Pa]
up to
Minimum 4D
Ø 200 mm
bend radius
[mm] above Ø 200
4.5xD
mm
Length [m] 1; 2; 3; 6

Packing

Cardboard
box

Order code

Thermovent Aero Flex Ø / length

Accessories
Backdraft
Diffusers and air disk valves Grilles and hoods dampers Fittings Clamps

338 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Pressure loss diagram per 1 m stretched air duct

Calculation example

• Select a curve that matches the air duct diameter [mm], 200 mm
in this case.
• Find the intersection point of this line with the vertical line of
the required air flow in m3/h, 500 m3/h in this case.
• The horizontal line that shows the pressure loss in Pa per 1 m
straight air duct crosses this intersection point.
• Multiply pressure loss value (2.4 Pa/m at 20°C) by total air duct
length to get the total pressure loss value. To calculate pressure loss
in case of bends consider each bend as extra air duct meter.

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 339


FITTINGS

Cross Tee
KM Series page

with polymeric coating 342

Cross Tee
KM…Zn Series page

galvanized steel 342

T-joint
TM Series page

with polymeric coating 343

T-joint
TM…Zn Series page

galvanized steel 343

Y-shaped T-joint
TMY Series page

with polymeric coating 344

Y-shaped T-joint
TMY…Zn Series page

galvanized steel 344

Reducer
RM Series page

with polymeric coating 345

Reducer
RM…Zn Series page

galvanized steel 345

Flange
FM Series page

with polymeric coating 346

340 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Flange
FM…Zn Series page

galvanized steel 346

Reducer
FMK Series page

with polymeric coating 347

Reducer
FMK…Zn Series page

galvanized steel 347

Flange
F Series page

with polymeric coating 348

Flange
FK Series page

galvanized steel 348

Reducer
PM series page

with polymeric coating 349

Reducer
PM…Zn series page

galvanized steel 349

Mounting kit
NM Isovent Series page
350

Clamps page
352

Bend holder (bracket)


PDV series page
354

Mounting tapes page


355

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 341


FITTINGS
CROSS TEES

KM KM…Zn Application
Series Series • For branch connections of the air ducts used in resi-
dential, public and industrial ventilation systems.
• For connection of various air ducts and their integra-
tion into complex ventilation systems.

Design
• Made of special steel with polymeric coating (KM se-
ries) or galvanized steel (KM…Zn series).
• The cross tee is designed for connection of 4 air ducts
of the same diameter at 90° angle.
• The cross tee model KM 125/160 is equipped with
two Ø 125 mm and two Ø 160 mm flanges.
• Ventilation system components are fixed by clamps
or any other fixing devices.

Overall dimensions

Dimensions [mm] B
Model ØD
D1 D2 B 1
KM 80 KM 80 Zn 80 80 170
KM 100 KM 100 Zn 100 100 190
KM 110 KM 110 Zn 110 110 200
KM 120 KM 120 Zn 120 120 210
KM 125 KM 125 Zn 125 125 215

Ø D2
Ø D2

KM 125/160 KM 125/160 Zn 125 160 215


KM 130 KM 130 Zn 130 130 220
KM 140 KM 140 Zn 140 140 230
KM 150 KM 150 Zn 150 150 240
KM 160 KM 160 Zn 160 160 250
KM 180 KM 180 Zn 180 180 260 ØD
KM 200 KM 200 Zn 200 200 300 1
KM 250 KM 250 Zn 250 250 350
KM 315 KM 315 Zn 315 315 415

Accessories
Backdraft Mounting
Diffusers and air disk valves Grilles and hoods dampers Clamps Air ducts tapes

342 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


FITTINGS
T-JOINTS

TM TM…Zn Application
Series Series • For branch connections of the air ducts used
in residential, public and industrial ventilation sys-
tems.
• For connection of various air ducts and their in-
tegration into complex ventilation systems.

Design
• Made of special steel with polymeric coating
(TM series) or galvanized steel (TM…Zn series).
• The T-joint is designed for connection of 3 air
ducts at 90° angle.
• The TM 125/160 T-joint model is equipped with
two � 125 mm flanges and one � 160 mm flange.
• Ventilation system components are fixed by
clamps or any other fixing devices.

Overall dimensions

Dimensions [mm] B
Model ØD
D1 D2 B 2
TM 80 TM 80 Zn 80 80 170
TM 100 TM 100 Zn 100 100 190
TM 110 TM 110 Zn 110 110 200
TM 120 TM 120 Zn 120 120 210
TM 125 TM 125 Zn 125 125 215

Ø D1
Ø D1

TM 125/160 TM 125/160 Zn 125 160 215


TM 130 TM 130 Zn 130 130 220
TM 140 TM 140 Zn 140 140 230
TM 150 TM 150 Zn 150 150 240
TM 160 TM 160 Zn 160 160 250
TM 180 TM 180 Zn 180 180 260
TM 200 TM 200 Zn 200 200 300
TM 250 TM 250 Zn 250 250 350
TM 315 TM 315 Zn 315 315 415

Accessories
Backdraft Mounting
Diffusers and air disk valves Grilles and hoods dampers Clamps Air ducts tapes

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 343


FITTINGS
Y-SHAPED T-JOINT

TMY TMY…Zn Application


Series Series • For branch connections of the air ducts used in
residential, public and industrial ventilation systems.
• For connection of various air ducts and their
integration into complex ventilation systems.

Design
• Made of special steel with polymeric coating (TMY
series) or galvanized steel (TMY…Zn series).
• The T-joint is designed for connection of 3 air ducts
with the same diameter at 120° angle.
• Ventilation system components are fixed by clamps
or any other fixing devices.

Overall dimensions

Dimensions [mm]
Model
D B
TMY 80 TMY 80 Zn 80 170
TMY 100 TMY 100 Zn 100 190
TMY 110 TMY 110 Zn 110 200
TMY 120 TMY 120 Zn 120 210
TMY 125 TMY 125 Zn 125 215
TMY 130 TMY 130 Zn 130 220
TMY 140 TMY 140 Zn 140 230
B

TMY 150 TMY 150 Zn 150 240


TMY 160 TMY 160 Zn 160 250
TMY 180 TMY 180 Zn 180 260
TMY 200 TMY 200 Zn 200 300
TMY 250 TMY 250 Zn 250 350
TMY 315 TMY 315 Zn 315 415

Accessories
Backdraft Mounting
Diffusers and air disk valves Grilles and hoods dampers Clamps Air ducts tapes

344 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


FITTINGS
REDUCERS

RM RM…Zn Application
Series Series • For branch connections of the air ducts used
in residential, public and industrial ventilation sys-
tems.
• For connection of various air ducts and their in-
tegration into complex ventilation systems.
• For connection of two various air duct dia­
meters.

Design
• Made of special steel with polymeric coating
(RM series) or galvanized steel (RM…Zn series).
• The reducer is designed for connection of two
air ducts with various diameters.
• Ventilation system components are fixed by
clamps or any other fixing devices.

Overall dimensions

Dimensions [mm]
Model L
D D1 L
RM 80/100 RM 80/100 Zn 80 100 115
RM 100/125 RM 100/125 Zn 100 125 125
RM 100/120 RM 100/120 Zn 100 120 125
RM 125/150 RM 125/150 Zn 125 150 125
RM 125/160 RM 125/160 Zn 125 160 144

1
RM 150/160 RM 150/160 Zn 150 160 172
RM 150/200 RM 150/200 Zn 150 200 172
RM 160/200 RM 160/200 Zn 160 200 154
RM 200/250 RM 200/250 Zn 200 250 172
RM 250/315 RM 250/315 Zn 250 315 195

Accessories
Backdraft Mounting
Diffusers and air disk valves Grilles and hoods dampers Clamps Air ducts tapes

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 345


FITTINGS
FLANGES

FM FM…Zn Application
Series Series • For connection of flexible and plastic air ducts of the
respective diameter.
• For wall or ceiling mounting.

Design
• Made of special steel with polymeric coating (FM se-
ries) or galvanized steel (FM…Zn series).
• Fixing to wall or ceiling with screws.

Overall dimensions

Dimensions [mm]
Model
D D1 L L
FM 80 FM 80 Zn 80 116 62
FM 100 FM 100 Zn 100 136 62
FM 110 FM 110 Zn 110 146 62
FM 120 FM 120 Zn 120 156 62
1

FM 125 FM 125 Zn 125 162 62


FM 130 FM 130 Zn 130 166 62
FM 140 FM 140 Zn 140 176 62
FM 150 FM 150 Zn 150 186 62
FM 160 FM 160 Zn 160 196 62
FM 180 FM 180 Zn 180 206 62
FM 200 FM 200 Zn 200 236 62
FM 250 FM 250 Zn 250 286 62
FM 315 FM 315 Zn 315 351 62

Accessories
Backdraft Mounting
Diffusers and air disk valves Grilles and hoods dampers Clamps Air ducts tapes

346 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


FITTINGS
REDUCERS

FMK FMK…Zn Application


Series Series • For connection of flexible and plastic air ducts of
the respective diameter.
• For wall or ceiling mounting.

Design
• Made of special steel with polymeric coating
(FMK series) or galvanized steel (FMK…Zn series).
• The flanges are equipped with a rectangular
connecting plate.
• Fixing to wall or ceiling with screws.

Overall dimensions

Dimensions [mm] L
Model
H B D L
FMK 80 FMK 80 Zn 130 114 80 50
FMK 100 FMK 100 Zn 150 134 100 50
FMK 110 FMK 110 Zn 158 142 110 50
FMK 120 FMK 120 Zn 162 146 120 50
FMK 125 FMK 125 Zn 170 156 125 50
FMK 130 FMK 130 Zn 180 164 130 50
FMK 140 FMK 140 Zn 190 174 140 50

H
FMK 150 FMK 150 Zn 204 188 150 50
FMK 160 FMK 160 Zn 210 194 160 50
FMK 180 FMK 180 Zn 220 204 180 50
FMK 200 FMK 200 Zn 250 234 220 50 B
FMK 250 FMK 250 Zn 300 284 250 50
FMK 315 FMK 315 Zn 360 344 315 50

Accessories
Backdraft Mounting
Diffusers and air disk valves Grilles and hoods dampers Clamps Air ducts tapes

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 347


FITTINGS
FLANGES

F 100 – F 200 FK Application


Series Series • For connection of flexible air ducts, plastic ducts and
air disk valves of suitable diameter without flan­ges.
• For wall or ceiling mounting.

Design
• Made of high-quality plastic.
• F Series flanges are equipped with a retaining ring for
fixation of flexible air ducts.
• The flange model F 200/150 can be used as a connec-
tor for the air disk valves A 200 VR and A 200 R.
• F 250 and F 315 flanges are equipped with an extra
X-deflector to reinforce the flange.
• FK Series flanges are equipped with a connecting
plate.
• Fixing to wall or ceiling with screws.
F 250 – F 315
Series

L
Overall dimensions
1

Dimensions [mm]
Model
D D1 D2 L
F 80 80 115 120 62
F 100 100 132 139 62

2
F 125 125 157 165 62
F 150 150 179 188 62
F 200 200 232 240 62
F 200/150 150 200 179 85
F 250 250 283 290 62 L
F 315 315 360 356 62

Dimensions [mm]
Model
H B D L
H

FK 100 185 169 100 34


FK 120 185 169 120 34
FK 125 185 169 125 34 B

Accessories
Backdraft Mounting
Diffusers and air disk valves Grilles and hoods dampers Clamps Air ducts tapes

348 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


FITTINGS
DUCT CONNECTOR

PM PM…Zn Application
Series Series • For connection of flexible air ducts of the re-
spective diameter.

Design
• Made of special steel with polymeric coating
(PM series) or galvanized steel (PM…Zn series).
• Fixing with clamps.

Overall dimensions

Dimensions [mm]
Model L
D L
PM 80 PM 80 Zn 80 62
PM 100 PM 100 Zn 100 62
PM 110 PM 110 Zn 110 62
PM 120 PM 120 Zn 120 62
PM 125 PM 125 Zn 125 62
PM 130 PM 130 Zn 130 62
PM 140 PM 140 Zn 140 62
PM 150 PM 150 Zn 150 62
PM 160 PM 160 Zn 160 62
PM 180 PM 180 Zn 180 62
PM 200 PM 200 Zn 200 62
PM 250 PM 250 Zn 250 62
PM 315 PM 315 Zn 315 62

Accessories
Backdraft Mounting
Diffusers and air disk valves Grilles and hoods dampers Clamps Air ducts tapes

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 349


FITTINGS
MOUNTING KIT

NM Isovent Use • The flanges of NM Isovent mounting kit


are made of high-quality impact-resistant
Series • NM Isovent mounting kits are designed for polystyrene. The flanges are connected to the
simple and comfortable connection of heat- ventilation equipment spigots with self-drilling
insulated air ducts to the spigots of various VENTS screws with drill.
ventilation equipment. The mounting kit consists
of flanges and matching self-drilling screws as Modifications
well as mounting clamps for air duct fixation.
• The flanges of NM Isovent mounting kit ensure • NM Isovent mounting kits are available in two
modifications:
tight connection of all the heat-insulated air duct
components to the ventilation equipment spigots NM Isovent 125 – compatible with round
and prevent insulation delamination in the Ø 125 mm air ducts;
connection points. NM Isovent 150 – compatible with round
Ø 150 mm air ducts;

Design

Overall dimensions

Model D1, mm D2, mm


NM Isovent 125 129 141
NM Isovent 150 154 170

A D1
A-A

17
3,5
44holes
отв.

D2
A 20

Delivery set
NM Isovent mounting kit delivery set includes:
- Flange 2 items
- Self-drilling screws with drill 8 items
- Mounting clamp 2 items
- Packing 1 item

350 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Mounting example of the heat-insulated air ducts with NM Isovent mounting kit

 

Cover the air handling unit spigots with the flanges from NM Isovent mounting kit and Cover the air handling unit spigots with the inner hoses of the heat-insulated air ducts
fix those with self-drilling screws with drill. and fix those with metal clamps (special accessory).

 

Tuck the inner insulation layer of the air ducts under the flanges of NM Isovent mount- Cover the flanges of NM Isovent mounting kit with inner hoses of heat-insulated air
ing kit. ducts by pressing the hoses tightly against the air handling unit casing and fixing those
with clamps (included into delivery).

 

Tighten the connection point between the inner hose of the heat-insulated air ducts Heat-insulated air ducts have reliable connection to the air handling unit spigots.
and the flanges of NM Isovent mounting kit with clamps.
The unit is ready to operate!

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 351


CLAMPS

CZK CZ C
Series Series series
(nylon)

Application Application Application


The quick-release clamps are designed for quick The quick-release clamp is designed for quick The nylon clamp is one of the fastest, cost-­effective
and reliable connection of various round ventila- and reliable mounting and connection of v­ a­rious and comfortable fixing devices for connection of
tion system components. round ventilation system components. The clamps the air ducts to the branch pipe and interconnec-
facilitate installation process and fan removal for tion any ductworks. Suitable for operation range
Design servicing and maintenance. from –40°C up to +85°C.
The clamp is made of galvanized steel band and
sealed with foamed rubber on the internal side for Design Design
vibration reducing. The clamp is suitable for wall The clamp is made of galvanized steel band and The clamps are made of high quality self-extin­
or ceiling mounting. sealed with foamed rubber on the internal side for guishing nylon with high mechanical durability.
better tight connection and vibration redu­cing. The edged locking device provides any diameter
The quick-release clamps are tightened with two fixation. The clamps length varies from 370 mm
bolts. to 1220 mm and the width from 4.8 to 9 mm. NZC
snips can be supplied together with clamps for
more comfortable tightening and cutting.

Overall dimensions Overall dimensions Overall dimensions


Dimensions [mm] Weight Dimensions [mm] Weight Dimensions [mm]
Model Model Model
D L [kg] D H [kg] D H L
CZK 100 100 204 0.21 CZ 100 100 172 0.206 C 370/100 N 102 4.8 370
CZK 125 125 229 0.22 CZ 125 125 198 0.232 C 530/100 N 140 7.6 530
CZK 150 150 254 0.25 CZ 150 150 224 0.296 C 710/100 N 190 9 710
CZK 160 160 264 0.26 CZ 160 160 232 0.358 C 780/100 N 229 9 780
CZK 200 200 304 0.31 CZ 200 200 274 0.42 C 912/100 N 263 9 912
CZK 250 250 354 0.35 CZ 250 250 326 0.55 C1220/100 N 365 9 1220
CZK 315 315 419 0.42 CZ 315 315 380 0.65

NZC snips

352 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


CLAMPS

C CB CBR
Series Series Series

Application release clamps equipped with a stainless steel 1. Bend the edge of the band;
The clamps are designed for quick and reliable swing screw. The clamps are tightened with a 2. Fix the bent end inside the band holder;
mounting and connection of various round ven- screw. 3. Turn the band holder up to the required dia­
tilation system components. The clamps ­facilitate • The CBR 3000 model is a band clamp in plastic meter marking on the casing;
installation process and fan removal for servicing casing (roll 30 m x 9 mm x 0.8 mm + 50 locking de- 4. Cut the band according to the marking on the
and maintenance. vices SU 50). Get the required clamp dia­meter with casing;
a clamp band of respective length and a locking de- 5. Fix the locking device on the band clamp.
Design vice. The clamps are tightened with a screw.
• C series clamps are made of stainless steel Snip cutters are everything you need to get the re-
band and CZ series clamps are made of galvanized quired clamp diameter as the plastic casing has a
steel band. The clamps are tightened with a screw. special design and necessary marking.
• CB series clamps are the stainless steel quick- Use:

Overall dimensions
Dimensions [mm]
Model
D H
C 100 90-110 9
C 125 110-130 9
C 150 140-160 9 1 2 3 4 5
C 160 150-170 9
C 200 190-210 9
C 250 240-260 9
C 315 300-330 9

Overall dimensions
Dimensions [mm]
Model
D H Locking device SU 50 for CBR 3000
CB 60-110 60-110 9
CB 60-135 60-135 9
CB 60-165 60-165 9

Easy locking mechanism for the CB and CBR clamps

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 353


WALL HOLDER (BRACKET)

PDV Application holders for 80 to 400 mm flexible ducts.

Series Quick and reliable mounting of round air ducts at 90°


angle. Provides correct bend angle of flexible air ducts Design
to reduce air resistance and noise in the system. Wall holder is made of high-quality plastic that pro-
Reduces energy demand of ventilation system and vides correct bending and is not deformed due to
increases its efficiency due to even structure and no air duct deflection. The air duct is fixed to the holder
sagging that disturb the smooth air motion in the with nylon clamps.
duct. The multi-functional design allows using the wall

Wrong mounting Correct mounting


air deflection increases air resistance and energy correct use of the wall holder reduces air resistance
demand of the system. and energy demand of the system.

Mounting example of flexible air ducts with the wall holder

End-to-end mounting Suspended mounting

354 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


ALUMINIUM MOUNTING TAPES

ALT ART PVT


Series Series Series

Application Design dard adhesive tape.


Insulating material for various construction, r­ epair The aluminium adhesive tape ALT is a com- The adhesive PVC tape is an insulation tape
and mounting operations at ventilation and air posite material that consists of aluminium and PET made of plasticized PVC base covered with a glue
conditioning systems. foil covered with glue layer. The tape is supplied in layer.
Insulation and protection of pipeline butt joints, rolls and the glue layer is protected with an extra - initial good adhesion only increases with time;
air ducts, casings, assembly units, etc. protecting layer. - sufficient stability against sliding;
Sealing of joints and seams in case of reflecting The aluminium adhesive tape ART is a com- - high thermal resistance;
material insulation to reduce thermal losses. posite material that consists of aluminium foil - high solvent resistance;
Reliable protection of equipment components reinforced with PET film and fibreglass that is cov- - increased UV resistance;
against vapour, dirt and dust penetration. Corro- ered with glue. Due to synthetic fibres the tape has - durability.
sion protection. higher mechanical durability as compared to stan-

ALT and ART tape overall dimensions

ALT 050/50 ALT 050/10 ART 050/50 ART 050/10

Length [m] 50 10 50 10
Width [mm] 50 50 50 50
Base thickness [μm] 30 30 55 55
Total tape thickness [μm] 32 32 96 96
Breaking force 57 N / 25 mm2 57 N / 25 mm2 336 N / 25 mm2 336 N / 25 mm2
Elongation at break [no more %] 3 3 6 6
Adhesiveness 8.25 N / 25 mm 2
8.25 N / 25 mm 2
10 N / 25 mm 2
10 N / 25 mm2
Operating temperature [°C] +10 ... +40 +10 ... +40 +10 ... +40 +10 ... +40
Max. working area surface [°C] +100 +100 +100 +100
UV-resistance yes yes yes yes

PVT tape overall dimensions

Type Length [m] Width [mm] Thickness [mm]

PVT 050/10 10 50 0.18


PVT 050/30 30 50 0.18
PVT 050/50 50 50 0.18

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 355


FLAT AND ROUND
PVC DUCTWORKS

"Plastivent" air ductwork system is the ideal solution for arrangement of ventilation systems in small and medium-sized
residential, office and commercial premises as well for connection of cooker hoods, exhaust hoods, cowls and other exhaust
equipment. It includes rectangular 55x110, 60x120, 60x204 mm air ducts, round Ø 100, 125, 150, 200 mm air ducts and a great
variety of fittings such as bends, reducers, connectors, etc. Operation temperature from -30 0C up to +70 0C.

Basic advantages of "Plastivent" system:


• A great variety of fittings designed for assembly of
complex ductworks with any geometry based exclusively on
"Plastivent" system components.
• Smooth inner duct surface provides low air resistance.
• Corrosion resistant properties ensure long service life.
• Low weight.
• Ventilation system based on "Plastivent" air ducts produces
lower noise level as compared to other systems with
corrugated or steel air ducts.
• Low thermal conductivity.
• Environmentally friendly plastic used for manufacture of
"Plastivent" system does not sustain combustion.

• Extremely easy mounting due to no complicated assembly


operations and special tools.
• Small overall dimensions of the rectangular components
allow using the system in limited area above false ceilings.
• Aesthetic view makes the system suitable for mounting in
ready-made premises.

356 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


page page page
364 365 365

Round duct Round telescopic duct Round flexible duct


connector

page page page


365 368 368

90° bend for round ducts 45° bend for round ducts T-joint for round ducts

page page page


368 369 369

Wall plate for round Round duct connector Connector with


ducts backdraft damper
for round ducts

page page page


370 370 371

Connector with back- Connector with plate Reducer


draft damper and wall for round ducts
plate for round ducts

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 357


page page page
372 372 373

Reducer Step round reducer Step round reducer

page page page


373 374 374

Round to flat connector Round flexible duct Holder for round ducts
connector

page page page


375 376 376

Flat duct Flat duct connector Flat duct connector


with damper

page page page


377 377 378

Flexible flat duct Air duct connector with Air duct connector with
connector a plate a plate and a back valve

page page page


378 379 379

Vertical 90° bend for Horizontal 90° bend for Versatile flat angular
flat ducts flat ducts connector

358 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


page page page
380 380 381

T-joint for flat ducts Flat duct holder 90° connecting bend for
flat and round ducts

page page page


381 382 382

T-joint for flat and Reducer for flat ducts Wall plate for flat ducts
round ducts

page page page


382 383 383

End grille End grille with air pass Reducer for flat and
regulation round ducts

page page
384 385

Wall plate with flange Round to flat connector


(symmetric)

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 359


APPLICATION EXAMPLES

Kitchen

360 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


APPLICATION EXAMPLES

Bathroom

Apartment

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 361


APPLICATION EXAMPLES

MV 120 VJ
Aluvent Ø125
Cafe Vents ВК 125
Aluvent Ø125

С 125

A 125 VRF

A 125 VRF

A 125 VRF

A 125 VRF

Aluvent Ø 150

A 150 VRF Aluvent Ø 125

A 125 VRF
Aluvent Ø 100

Plastivent as extension of tin air ducts A 100 VRF

362 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


APPLICATION EXAMPLES

House Aluvent Ø 125

C 125

C 125
Aluvent Ø 125

C 125

A 125 VR A 125 VR

A 125 VR
A 125 VR

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 363


APPLICATION EXAMPLES

Office

Aluvent Ø125

Aluvent Ø125

C 125 A 125 VRF


C 125

A 125 VRF Aluvent Ø150

Vents VK 150

FB 150
MVM 300

364 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


APPLICATION EXAMPLES

Vents 150 VK

Aluvent Ø125
C 125

A 125 VRF Aluvent Ø125


C 125

A 125 VRF Aluvent Ø125


C 125

C 125
A 125 VRF

A 125 VRF
Aluvent Ø125
C 125

A 125 VRF

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 365


ROUND PVC DUCTWORK SYSTEM

Round duct Application


• Supply and exhaust ventilation of various premises.
• Formation of round air ductworks.

Design D1

• Made of white PVC.


• Diameters: 100, 125, 150 and 200 mm.
• Duct length from 350 to 2500 mm.
• Connected with matching diameter connectors. L D

Dimensions [mm] Dimensions [mm]


Code Code
D D1 L D D1 L
30
10035 100 103 350 3020 150 153 2000
20035 125 128 350 25
4020 200 204 2000
30035 150 153 350 1025 100 103 2500
40035 200 204 350 20
2025 125 128 2500
1005 100 103 500 3025 150 153 2500
2005 125 128 500 4025 200 204 2500
15
3005 150 153 500 10035/2 104 107 350
4005 200 204 500 20035/2 129 132 350
10
1010 100 103 1000 1005/2 104 107 500
2010 125 128 1000 2005/2 129 132 500
5
3010 150 153 1000 1010/2 104 107 1000
4010 200 204 1000 2010/2 129 132 1000
0
1015 100 103 1500 0 1015/2
100 200 104 400
300 107 600
500 1500 800
700

2015 125 128 1500 2015/2 129 132 1500


3015 150 153 1500 1020/2 104 107 2000
4015 200 204 1500 2020/2 129 132 2000
1020 100 103 2000 1025/2 104 107 2500
2020 125 128 2000 2025/2 129 132 2500

30 30
Pressure loss [Pa]

Pressure loss [Pa]

25 25
1010/2 (ø100 mm)
1010 (ø100 mm)
2010 (ø125 mm)
20 20

15 15
3010 (ø150 mm)
2010/2 (ø125 mm)
10 10

5 4010 (ø200 mm) 5

0 0
0 100 200 300 400 500 600 700 800 0 100 200 300 400 500 600
Air flow [m3/h] Air flow [m3/h]

Data for 1 m air duct section

30

25

20

15

10

366 5
VENTS. Domestic ventilation. Catalogue №6 | 02-2020
Round telescopic duct Application Design
• Supply and exhaust ventilation of various • Made of white PVC.
premises.
• Telescopic design of two parts.
• Wall mounting.
• Diameters: 100, 125, 150 mm.
• Air duct length is adjusted within 300 to 500
or 500 to 1000 mm.
Dimensions [mm]
Code D1 D3
D D1 D2 D3 L
1805 100 103 104 107 300-500
2805 125 128 129 132 300-500
3805 150 153 154 157 300-500
D L D2
1810 100 103 104 107 500-1000
2810 125 128 129 132 500-1000
inner duct outer duct
3810 150 153 154 157 500-1000

Round flexible Application Design


duct connector • Supply and exhaust ventilation of various • Made of white PVC.
premises.
• Cover the connector with air duct and fix it
• Connection of flexible round ducts. with clamps.
• Connecting diameters: 100, 125, 150, 200 mm.

Dimensions [mm] D1
Code
a D D1
1113 60 100 103
2123 60 125 128
3133 60 150 153
4143 60 200 204 a D

90° bend Application Design


for round ducts • Supply and exhaust ventilation of various • Made of white plastic.
premises.
• Connecting diameters: 100, 125, 150 mm.
• Connection of same diameter air ducts at
90°.

Dimensions [mm]
Code
D D1 a b
a

121 100 97 137 30


222 125 122 164 30
323 150 147 189 30 D1 b
70
D
Pressure loss [Pa]

60
222 (ø125 mm)

50

40
121 (ø100 mm)
30

20

323 (ø150 mm)


10

0
0 100 200 300 400 500 600 700 800
Air flow [m3/h]

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 367


ROUND PVC DUCTWORK SYSTEM

45° bend Application


for round ducts • Supply and exhaust ventilation of various premises.
• Connection of same diameter air ducts at 45°.

Design Dimensions [mm]


Code
• Made of white plastic. D D1 a b c
• Connecting diameters: 100, 125 mm. 121-45 103 100 125 30 129
20
222-45 128 125 157 40 162

Pressure loss [Pa]


18

16
121-45 (ø100 mm)

с
14

12

10

b
a
D1
8
D
6

4
222-45 (ø125 mm)
2

0
0 50 100 150 200 250 300 350
Air flow [m3/h]

T-joint Application
for round ducts • Formation of branch connections in supply or exhaust ventilation systems located in residential,
public and other buildings.
• Connection of same diameter round ducts and integration into complex ventilation systems.

Design
• Made of white plastic.
• Connection of same diameter three round ducts at 90°.
• Connecting diameters: 100, 125, 150 mm.
D
Dimensions [mm] D1
Code b
D D1 a b c
131 100 97 173 30 139
c

232 125 122 198 30 164


333 150 147 223 30 189
D1 a
D

Wall plate Application


for round ducts • Supply and exhaust ventilation of various premises.
• Connection of air ducts to ventilation shafts.
• Decoration of mounting openings.

Design
• Made of white plastic.
• Screw fixing to wall.
• Connecting diameters: 100, 125, 150, 200 mm.

Dimensions [mm]
Code
D h a b
b

15 103 3 150 134


D

25 128 3 170 154


35 151 3 204 188
45 204 3 250 230
a h

368 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Round Application
duct connector • Supply and exhaust ventilation of various premises.
• Connection of same diameter air ducts.

Design
• Made of white plastic.
• Designed for direct installation into air duct and equipped with a lock ring.
• Connecting diameters: 100, 125, 150, 200 mm.

Dimensions [mm] D
Code
D D1 a
111 100 96 62
212 125 123 62
313 150 148 62
414 200 197 62 a D1

Connector Application
with backdraft damper • Supply and exhaust ventilation of various premises.

for round ducts • Connection of same diameter air ducts.

Design
• Made of white plastic.
• Equipped with a backdraft damper for back flow prevention.
• Designed for direct installation into air duct and equipped with a lock ring.
• Connecting diameters: 100, 125, 150, 200 mm.

Dimensions [mm] D
Code
D D1 a
1111 100 96 62
2121 125 123 62
3131 150 148 62
4141 200 197 62 a D1

120
Pressure loss [Pa]

2121 (125)
100

80

60
3131 (150)

4141 (200)
40
1111 (100)

20

0
0 200 400 600 800 1000 1200 1400
Air flow [m3/h]

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 369


ROUND PVC DUCTWORK SYSTEM

Connector with backdraft Application


damper and wall plate • Supply and exhaust ventilation of various premises.

for round ducts • Connection of same diameter air ducts.


• Decoration of mounting openings.

Design
• Made of white plastic.
• Equipped with a wall plate for decoration of mounting openings.
• Equipped with a backdraft damper for back flow prevention.
• Screw fixing to wall.
• Connecting diameters: 100, 125, 150, 200 mm.
D
Dimensions [mm]
Code
a b c D
1511 150 134 62 100

b
2521 170 154 62 125
3531 204 188 62 150
4541 250 230 62 200
a c

Connector with plate Application


for round ducts • Supply and exhaust ventilation of various premises.
• Connection of same diameter air ducts.
• Decoration of mounting openings.

Design
• Made of white plastic.
• Equipped with a wall plate for decoration of mounting openings.
• Screw fixing to wall.
• Connecting diameters: 100, 125, 150, 200 mm.
D
Dimensions [mm]
Code
a b c D
b

151 150 134 62 100


252 170 154 62 125
353 204 188 62 150
454 250 230 62 200
a c

370 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Reducer Application
• Supply and exhaust ventilation of various premises.
• Connection of various diameter air ducts.

Design
• Made of white plastic.
• Connecting diameters: 80-100, 100-120, 100-125, 100-150, 125-150, 150-200 mm.

Dimensions [mm]
Code
a D1 D2 D3 D4
110 60 103 100 76 80

D1

D3

D4
D2
211 60 129 125 96 100
311 96 154 150 98.5 100
312 60 154 150 121 125
413 71 204 200 146 150 a
611 60 124 120 98.5 99

60 60 140 140
Pressure loss [Pa]

Pressure loss [Pa]


120 120
50 50

100 100
40 40 211 (Convergent)

110 (Convergent) 80 80
30 30
60 60

20 20
40 40
110 (Divergent) 211 (Divergent)
10 10
20 20

0 0 0 0
0 50 0 10050 150100 200150 250200 300250 350300 350 0 0 200 200400 400600 600800 800
Air flow [m3/h] Air flow [m3/h]

180 140 80 180 60 80


Pressure loss [Pa]

Pressure loss [Pa]

160 70 160 70
120
50
140 140
60 60
100
120 120 40
50 50
311 (Convergent)
100 80 100
40 30 40
80 60 80 312 (Convergent)
30 30
60 60 20
40
20 20
40 40 312 (Divergent)
10
20
20 10 20 10
311 (Divergent)
0 0 0 0 0 0
0 100 0 200 300 200400 500 400600 700 600
800 800 0 100 0 100
200 200
300 300
400 400
500 500
600 600700 700 800 0 0 200 100 200
400 300 400
600 500 800600 700
Air flow [m3/h] Air flow [m3/h]

40 60 180 30 80 30
Pressure loss [Pa]

Pressure loss [Pa]

160 70
20
50 25 25
140
60
00
611 (Convergent)
40 120 20 20
50
80 100 413 (Convergent)
30 15 40 15
60 80
30
20 60 10 10
40
20
40
10 5 5 611 (Divergent)
20
20 413 (Divergent) 10

0 0 0 0 0 0
0 0 200 200400 400600 600800 800 0 100 0 200 300 200
400 500 400
600 700 600
800 800 0 100 200
0 300
100 400
200 500
300 600
400 700
500 600 7
Air flow [m /h] 3
Air flow [m3/h]

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 371


ROUND PVC DUCTWORK SYSTEM

Reducer Application
• Supply and exhaust ventilation of various premises.
• Connection of Ø 120 and 125 mm round air ducts.

Design
• Made of white plastic.
• Connecting diameters: 125-129 mm.

Dimensions [mm]
Code

D1
D2

D3

D4
a D1 D2 D3 D4
216 42 129 125 115 119
30 30
Pressure loss [Pa]

25 25 a

20 20

15 15
216 (Convergent)

10 10

216 (Divergent)
5 5

0 0
0 200 400 600 800 0 100 200 300 400 500 600 700
Air flow [m3/h]

Round step reducer Application


• Supply and exhaust ventilation of various premises.
• Connection of various diameter air ducts.
a
Design
• Made of white plastic.
• Connecting diameters: 80-100-120-125-150 mm.

100
150

125

120

Cut out spare length piece to get the required size. 80

Dimensions [mm]
Code
a Ø
310 125 80-100-120-125-150

180 80
Pressure loss [Pa]

Pressure loss [Pa]

310 – Convergent 310 – Divergent


 
160
 
120-80 70  
120-80
 
120-100  
120-100
140
 
125-80 60  
125-80
 
125-100   
125-100

120
 
125-120 50  
125-120

100  
150-80  
150-80
 
150-100  40  
150-100 
80  
150-120  
150-120
 
150-125
 30
 
150-125
60
 
  20 
40

20 10 
   
0 0
0 100 200 300 400 500 600 700 800 0 100 200 300 400 500 600 700 800
Air flow [m3/h] Air flow [m3/h]

372 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


a

a
Eccentric Application
reducer • Supply and exhaust ventilation of various premises.

D1 D1

D5 D5
D4 D4
D2 D2

D3 D3
• Connection of round ducts.

Design
• Made of white plastic. 2118
a
• Connecting diameters: 100, 120, 125, 130, 150 mm.
a

Dimensions [mm]
Code

D1 D1

D6
D4
D3
D2 D2

D5
a D1 D2 D3 D4 D5 D6

D6
D4
D3
D5
2118 90 125 120 123 103 99 -
3128 96 151 148 152 132 129 125
3128
140 60
Pressure loss [Pa]

Pressure loss [Pa]


120
50

100
40
2118 (Convergent)
80
3128 (Convergent)
30

60

20
40

2118 (Divergent) 3128 (Divergent)


10
20

0 0
0 200 400 600 800 0 200 400 600 800
Air flow [m3/h] Air flow [m3/h]

Round to flat connector Application


• Supply and exhaust ventilation of various premises. 30 30
• Connection of round and flat ducts.

Design
• Made of white plastic.
• Direct connection to round and flat ducts. L

•  onnecting ducts: 100-55x110, 100-60x122,


C D1
125-60x204, 150-90x220 mm.
D2

Dimensions [mm]
Code
a a1 b b1 D1 D2 L
511 113 110 59 55 103 100 137
a
711 124 122 64 60 103 100 137
a1
812 208 204 64 60 128 125 140
913 224 220 94 90 150 146 165
b1
b

30 25
Pressure loss [Pa]

Pressure loss [Pa]

812
511 (60x204/125)
(55x110/100) Convergent
25
Convergent 20
511
(55x110/100) 812
711 913 (60x204/125)
20 Divergent
(60x122/100) (90x220/150) Divergent
Convergent Convergent 15

15 711
(60x122/100)
10 Divergent

10

5 913
5 (90x220/150)
Divergent

0 0
0 100 200 300 400 500 600 700 800 0 100 200 300 400 500 600 700 800
Air flow [m3/h] Air flow [m3/h]

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 373


ROUND PVC DUCTWORK SYSTEM

Round flexible duct connector Application


• Supply and exhaust ventilation of various premises.
• Connection of flexible ducts with plastic system components.

Design
• Made of white plastic.
• Connection to flexible air ducts without clamps.
• Flexible spiral seam duct is connected to one side and the other side is connected to Ø 100 mm
flange.
• Left or right (R) thread. Right thread connectors are used with Polyvents air ducts.

Dimensions [mm]
Code
A B C D E

(inner)

E
A
D
1214 90 30 60 100 110
1214R 90 30 60 100 110
B
C

Round flexible duct connector Application


• Supply and exhaust ventilation of various premises.
• Connection of flexible ducts with plastic system components.

Design
• Made of white plastic.
• Connection to flexible air ducts without clamps.
• Flexible spiral seam duct is connected to one side and the other side is connected to Ø 100 mm
air duct.
• Left or right (R) thread. Right thread connectors are used with Polyvents air ducts.

Dimensions [mm]
Code
(outer)

A B C D E

E
A
D

1215 90 30 60 100 110


1215R 90 30 60 100 110
B
C

Holder Application
for round ducts • Supply and exhaust ventilation of various premises.
• Mounting of round ducts to wall, ceiling or any other plane surface.

Design
• Made of white plastic.
• Fixation to plane surface with screws.
• Special snaps provide reliable fixation of the duct with the holder.
• Connecting diameters: 100, 125, 150, 200 mm.

b
Dimensions [mm]
Code
a b D
16 113 20 103
D

26 138 20 128
a

36 163 20 153
46 213 20 203

374 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


FLAT PVC DUCTWORK SYSTEM

Flat air duct Application


• Supply and exhaust ventilation of various premises.
• Formation of flat air ductworks.

Design
• Made of white PVC.
• Size: 55x110, 60x122, 60x204, 90x220 mm.
• Duct length from 350 to 2500 mm.
• Connected with matching connectors.

b
b1

a1
a
L

Dimensions [mm]
Code
a b a1 b1 L
50035 55 110 52 107 350
70035 60 122 57 119 350
80035 60 204 57 200 350
90035 90 220 86 216 350
5005 55 110 52 107 500
7005 60 122 57 119 500
8005 60 204 57 200 500
5010 55 110 52 107 1000
7010 60 122 57 119 1000
8010 60 204 57 200 1000
9010 90 220 86 216 1000
5015 55 110 52 107 1500
7015 60 122 57 119 1500
8015 60 204 57 200 1500
9015 90 220 86 216 1500
5020 55 110 52 107 2000
7020 60 122 57 119 2000
8020 60 204 57 200 2000
9020 90 220 86 216 2000
5025 55 110 52 107 2500
7025 60 122 57 119 2500
8025 60 204 57 200 2500
9025 90 220 86 216 2500

70
Pressure loss [Pa]

60
5010 (55x110)

50

40

7010 (60x122)
30

8010 (60x204)
20
9010 (90x220)

10

0
0 200 400 600 800 1000
Air flow [m3/h]

Data for 1 m air duct section

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 375


FLAT PVC DUCTWORK SYSTEM

Flat duct connector Application


• Supply and exhaust ventilation of various premises.
• Connection of same sized flat ducts.

Design
• Made of white plastic.
• Designed for installation into air duct and equipped with a lock ring for easy jointing.
• Connecting sizes: 55x110, 60x122, 60x204, 90x220 mm.

b1
Dimensions [mm]
Code c
a b a1 b1 c b
515 56 110 59 114 66

a1
717 60 122 65 126 69

a
818 60 204 65 209 62
919 90 220 95 225 62

Flat duct connector Application


with damper • Supply and exhaust ventilation of various premises.
• Connection of same sized flat ducts.

Design
• Made of white plastic.
• Designed for installation into air duct and equipped with a lock ring for easy jointing.
• Equipped with a backdraft damper for back flow prevention.
• Connecting sizes: 55x110, 60x122, 60x204, 90x220 mm.

b1
Dimensions [mm]
Code c
a b a1 b1 c b
5151 56 110 59 114 66

a1
7171 60 122 65 126 69 a
8181 60 204 65 209 62
9191 90 220 95 225 62

30
Pressure loss [Pa]

25

5151 (55x110)
20

8181 (60x204)
15 7171 (60x122)

10
9191 (90x220)

0
0 100 200 300 400 500
Air flow [m3/h]

376 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Flexible Application
flat duct connector • Supply and exhaust ventilation of various premises.
• Connection of same sized flat flexible ducts.

Design
• Made of white PVC.
• Cover the connector with air duct and fix it with clamps.
• Connecting sizes: 55x100, 60x122, 60x204 mm.

b
Dimensions [mm]
Code b1 c
a b a1 b1 c
5153 55 110 52 107 60

a1

a
7173 60 122 57 119 60
8183 60 204 57 200 60

Air duct connector Application


with a plate • Supply or exhaust ventilation of various premises.
• Connection of single size flat air ducts.
• Decoration of mounting opening and connections to wall.

Design
• Made of white plastic.
• Air ducts are fitted inside the connector.
• Equipped with lock rings for easy adjustment.
• Screw fixing to wall.
• Connecting sizes: 55x110, 60x120, 60x204 mm.

Dimensions [mm]
Code
a b c A B C D L
555 110 55 2 141 154 154 141 131
757 120 60 2 141 154 154 141 131
858 204 60 3 229 154 242 141 186

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 377


FLAT PVC DUCTWORK SYSTEM

Air duct connector Application


with a plate and • Supply or exhaust ventilation of various premises.

a back valve • Connection of single size flat air ducts.


• Decoration of mounting opening and connections to wall.

Design
• Made of white plastic.
• Air ducts are fitted inside the connector.
• Equipped with lock rings for easy adjustment.
• Equipped with a back valve to prevent back drafting.
• Screw fixing to wall.
• Connecting sizes: 55x110, 60x122, 60x204 mm.
Dimensions [mm]
Code
a b c A B C D L
5551 110 55 2 141 154 154 141 131
7571 120 60 2 141 154 154 141 131
8581 204 60 3 229 154 242 141 186
30
Pressure loss [Pa]

25

5551 (55x110)
20

8581 (60x204)
15 7571 (60x122)

10

0
0 100 200 300 400 500
Air flow [m3/h]

Vertical 90° bend Application


for flat ducts • Supply and exhaust ventilation of various premises.
• Connection of same sized flat ducts at 90° vertically.

Design
• Made of white plastic.
• Connecting sizes: 55x110, 60x122, 60x204, 90x220 mm.

Dimensions [mm] b
Code
a b c a
5252 55x110 89 32
c

7272 60x122 93 32
8282 60x204 103 32
b

9292 90x220 130 35


a

16
Pressure loss [Pa]

14

  c
5252 (55x110)  
12
 
9292 (90x220)

10
 
7272 (60x122)
 
8282 (60x204)
 
8

0
0 100 200 300 400 500
Air flow [m3/h]

378 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Horizontal 90° bend Application
for flat ducts • Supply and exhaust ventilation of various premises.
• Connection of same sized flat ducts at 90° horizontally.

Design
• Made of white plastic.
• Connecting sizes: 55x110, 60x122, 60x204, 90x220 mm.

Dimensions [mm] c
Code
a b c
5251 55x110 143 32
7271 60x122 155 32

a
b
8281 60x204 238 32

c
9291 90x220 262 35
16
Pressure loss [Pa]

a
14
b
 
5251 (55x110) 
12
 
7271 (60x122)

10
 
9291 (90x220) 
 
8281 (60x204)
8

0
0 100 200 300 400 500
Air flow [m3/h]

Versatile flat Application


angular connector • Supply and exhaust ventilation of various premises.
• Angular connection of flat ducts.

Design
• Made of white plastic.
• Turning point angle from 3° to 48°.
• Depending on selected turning angle one connector side is cut out. Connection to the flat duct
through matching sized connector.
• On flange side direct connection to flat duct of respective size.
• Connecting section: 55x100 and 60x204 mm.
a
Dimensions [mm]
Code 32
a b c
52510 190 143 55x110
82810 286 247 60x204
10
c
Pressure loss [Pa]

8
52510 (55x110)
c

3
82810 (60x204)
2

0
0 50 100 150 200 250 300 350
Air flow [m3/h]
Data for 45° angle

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 379


FLAT PVC DUCTWORK SYSTEM

T-joint Application
for flat ducts • Formation of branch connections in supply or exhaust ventilation systems located in residential,
public and other buildings.
• Connection of same sized flat ducts and integration into complex ventilation systems.

Design
• Made of white plastic.
• Connection of same sized three flat ducts at 90°.
• Connecting sizes: 55x110, 60x122, 60x204, 90x220 mm.
• Direct connection to matching sized ducts.

Dimensions [mm]
Code
a b c

c
535 144 174 55x110

a
737 155 185 60x122
838 248 288 60x204
939 261 296 90x220
c
b

Flat duct holder Application


• Supply and exhaust ventilation of various premises.
• Mounting of flat ducts to wall, ceiling or any other plane surface.

Design
• Made of white plastic.
• Fixation to plane surface with screws.
• Specially designed configuration provides reliable duct to holder fixation and quick dismantling.
• Connecting sizes: 55x110, 60x122, 60x204, 90x220 mm.

c
Dimensions [mm]
Code
a b c

b
56 114 59 74
76 126 64 86
86 209 65 169 a
96 227 95 175

380 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


90° connecting bend Application
for flat and round ducts • Supply and exhaust ventilation of various premises.
• Connection of flat and round ducts at 90°.

Design
• Made of white plastic.
• Connecting dimensions: 55x110-100, 60x122-100, 60x204-100, 60x204-125, 60x204-150, 90x220-125,
90x220-150 mm.
• Flat ducts have direct connection and round ducts are connected through a matching connector.

Dimensions [mm] D1
Code
a D D1 b h L D
521 55x110 100 103 58x113 87 138
721 60x122 100 103 63x125 87 140

h
821 60x204 97 100 64x208 92 220

b
a
822 60x204 122 125 64x208 92 220
L
823 60x204 147 150 64x208 92 220
922 90x220 122 125 94x226 120 230
923 90x220 147 150 94x226 120 230
70
Pressure loss [Pa]

 
821(60x204/100),  521 (55x110/100),

60  
721(60x122/100),  822 (60x204/125),
 
823 (60x204/150),  
923 (90x220/150), 
50
 
922 (90x220/125) 
40

 
30 
20

10


0
0 100 200 300 400 500 600 700 800
Air flow [m3/h]

T-joint Application
for flat and round ducts • Formation of branch connections in supply or exhaust ventilation systems located in residential,
public and other buildings.
• Connection of flat and round ducts.

Design
• Made of white plastic.
• Connecting dimensions: 55x110-100 mm. D1
• Direct connection to air duct. D

Dimensions [mm] L
Code
axb D D1 c d h L
531 55x110 100 103 58 113 87 172 d
b
h

a
c

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 381


FLAT PVC DUCTWORK SYSTEM

Reducer Application Design


for flat ducts • Supply and exhaust ventilation of various • Made of white plastic.
premises.
• Connecting dimensions: 55x110-60x204
• Connection of flat different sized ducts. mm.
b

Dimensions [mm]
Code

c
b a c
518 60x204 55x110 30

c
a

Wall plate Application


for flat ducts • Supply and exhaust ventilation of various premises.
• Connection of air ducts to ventilation shafts.
• Decoration of mounting openings.

Design
• Made of white plastic.
• Screw fixing to wall. a
• Connecting sizes: 55x110, 60x122, 60x204 mm.

Dimensions [mm]
Code

b
E
e
a b c d e D E
55 111 56 2 141 141 154 154
75 123 61 2 141 141 154 154
d c
85 205 61 3 229 141 242 154
D

End grille Application


• Decoration of supply or exhaust vents of public, residential and industrial ventilation systems.
• Correct air flow distribution in premises.
• Wall or ceiling mounting.

Design
• Made of white plastic.
• Detachable front part facilitates cleaning.
• Modification with an insect screen (s) is available.
• Connecting dimensions: 55x110 and 60x204 mm.
f
Dimensions [mm]
Code
a b c d e f
d
a

571 88 137 114 59 73 9


871 93 232 208 64 76 9 b e
140 c
Pressure loss [Pa]

120
571 (55x110)
100

80

60

40
871 (60x204)

20

0
0 50 100 150 200 250 300 350
Air flow [m3/h]

382 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


End grille Application
with air pass regulation • Decoration of supply or exhaust vents of public, residential and industrial ventilation systems.
• Correct air flow distribution in premises.
• Wall or ceiling mounting.

Design
• Made of white plastic.
• Equipped with a movable flap for air flow regulation.
• Air pass is regulated with a tilt wand.
• Detachable front part facilitates cleaning.
• Modification with an insect screen (s) is available.
• Matches with 55x110 and 60x204 mm air ducts.
f
Dimensions [mm]
Code
a b c d e f

d
572 88 137 114 59 73 18
872 93 232 208 64 76 18 b e
c
350
Pressure loss [Pa]

300
572 (55x110)
250

200

150

100
872 (60x204)
50

0
0 50 100 150 200
Air flow [m3/h]

Reducer for flat Application


and round ducts • Supply and exhaust ventilation of various premises.
• Flat to round duct connection.

Design
• Made of white plastic.
• Connecting dimensions: 55x110-100 mm.
• Direct connection of reducer to round and flat ducts.
b
Dimensions [mm]
Code
cxb ØD f a
115 58x114 103 62 32
D
c

35
Pressure loss [Pa]

30 a
f
25

115
20 (55x110/100)
Convergent

15

115
10 (55x110/100)
Divergent

0
0 50 100 150 200 250 300 350
Air flow [m3/h]

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 383


FLAT PVC DUCTWORK SYSTEM

Reducer for flat Application


and round ducts • Supply and exhaust ventilation of various premises.
• Flat to round duct connection.

Design
• Made of white plastic.
• Connecting dimensions: 55x110-100 mm.
• Reducer has direct connection to flat air ducts and connection through connector to round ducts.

Dimensions [mm]
Code
cxb ØD f a

D
c
1156 58x114 100 62 32
35
Pressure loss [Pa]

a
30
f
25

1156
20 (55x110/100)
Convergent

15

1156
10 (55x110/100)
Divergent

0
0 50 100 150 200 250 300 350
Air flow [m3/h]

Wall plate with flange Application


• Supply and exhaust ventilation of various premises.
• Connection of air ducts to ventilation shafts.
• Decoration of mounting openings.

Design
• Made of white plastic.
• Screw fixing to wall.
• Connecting sizes: 60x122 mm.

Dimensions [mm]
Code
a b c d D e E
750 126 172 3 65 113 60 65

384 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Round to flat connector Application
(symmetric) • Supply and exhaust ventilation of various premises.
• Connection of round and flat ducts.

Design
• Made of white plastic. a D1
b D
• Direct connection flat duct, connection to
round duct with connector.

h
e
Connecting ducts: 100-60x122 mm.

Dimensions [mm]
Code c c
a b c ØD Ø D1 e h L
7112 124 122 30 100 103 60 64 137
160
Pressure loss [Pa]

140
L

120

7112
100 (60x122/125)
Convergent
80

60

40

7112
20 (60x122/125)
Divergent

0
0 100 200 300 400 500 600 700 800
Air flow [m3/h]

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 385


ROUND AND FLAT FOLDING
PVC DUCT SYSTEM

Introducing folding plastic ducts – an innovative and versatile solution for ventilation systems from VENTS. The folding duct
construction benefits logistics and results in significant space savings immediately apparent while storing and handling the
products.

Y :20
QT

0
Y: 2
QT

The compact folding duct from VENTS offer a number of advantages:


• 40 % higher transportation efficiency – more units per dispatch
• 60 % less warehouse storage space required
• Improved showroom stock diversity – even at small shops
• 20 % less time required for duct processing and fastening
• Easy and efficient mounting, better fit of parts made of elastic polymer material
• Compatible with the standard connectors and fixtures of PLASTIVENT air duct systems

-20 %
-40 %
-60 %

TRANSPORT COST STORAGE SPACE SAVINGS TIME SAVINGS IN


SAVINGS PROCESSING AND
INSTALLATION OF
ELEMENTS
386 VENTS. Domestic ventilation. Catalogue №6 | 02-2020
ROUND AND FLAT FOLDING PVC DUCT SYSTEM

Round duct Purpose


• Supply and exhaust ventilation systems of various spaces
• Building round ventilation ductwork systems

Construction
• White PVC plastic
• Diameter: 100
• Duct length ranges from 350 to 2.500 mm
• Joined by means of appropriate diameter connectors

Dimensions [mm]
Code
D D1 L
10035-1 100 103 350
1005-1 100 103 500
1010-1 100 103 1000
1015-1 100 103 1500
1020-1 100 103 2000
1025-1 100 103 2500

D1

L
D

Flat duct Purpose


• Supply and exhaust ventilation systems of various spaces
• Building flat ventilation ductwork systems

Construction
• White PVC plastic
• Cross-section: 55x110
• Duct length ranges from 350 to 2.500 mm
• Joined by means of appropriate section connectors

Dimensions [mm]
Code
a b a1 b1 L
50035-1 55 110 52 107 350
5005-1 55 110 52 107 500
5010-1 55 110 52 107 1000
5015-1 55 110 52 107 1500
5020-1 55 110 52 107 2000
5025-1 55 110 52 107 2500

b
b1
a1
a

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 387


ACCESS DOORS FOR ACCESSING
CONCEALED EQUIPMENT
AND UTILITY LINES

Access doors page


Access doors page
D (D2) series DPV series
Plastic
389 Plastic
390

Access doors Access doors


DZ series page DD series page
Plastic 391 Plastic 392
(with lock) (double sided hinges)

Access doors
Access doors page page
DMZ series
DM series
Metal
393 Metal 394
(with lock)

Access doors page


Access doors page
DMR series DMV series
Metal
395 Metal
396

Access doors Access doors


DKP series page DKM series page
Recessed for 397 Recessed for 398
ceramic tiles ceramic tiles

Access doors Access doors


DG series page DPM series page
Designed for plasterboard 399 Designed for 400
wall or ceiling application ceiling mounting

388 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


D series Application • Press gently to open and close.

• Designed for wall or ceiling application.


• The swinging D2 doors provide maximum
clearance while accessing utility lines.
• Enable quick and convenient access to
• A wide range of sizes.
concealed equipment and utility lines.
• Suitable for high-humidity areas. Mounting
• Protected by national patents worldwide. • Easy mounting using mortar or glue.
• Universal mountings for left or right-side
Design opening.
• Made of high-quality ABS plastic. • Easy servicing.
• Left or right-side opening.

Sample installations

D2 series

Plastic access doors opening


from either side
D series

Dimensions
Dimensions [mm]
Model
H B H1 B1 H2 L1 L B2
D 100x100 137 137 93 93 98 5 25 98
D 150x150 167 167 123 123 147 5 25 147
D 150x200 217 167 173 123 197 5 25 147
D 150x300 317 167 273 123 297 5 25 147
D 200x200 217 217 173 173 197 5 25 197
D 200x250 267 217 223 173 247 5 25 197
D 200x300 317 217 273 173 297 5 25 197
D 200x400 417 217 373 173 397 5 25 197 D2 series
D 250x250 267 267 246 246 247 5 25 247
D 250x300 347 267 303 223 327 5 25 247
D 250x400 417 267 373 223 397 5 25 247
D 300x300 317 317 273 273 297 5 25 297
D 300x400 417 317 373 273 397 5 25 297
D 300x500 517 317 473 273 497 5 25 297
D 300x600 617 317 573 273 597 5 25 297
D 400x500 517 417 473 373 497 5 25 397
D 400x600 617 417 573 373 597 5 25 397
D2 300x300 317 288 273 244 297 5 25 268
D2 400x400 416 388 372 344 397 5 25 370

Color options

White Beige Grey Sky Blue Beige Marble Grey Marble Blue Marble Green Marble

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 389


ACCESS DOORS

DPV series Application • Left or right-side opening.

• Designed for wall or ceiling application.


• Press gently to open and close.

• Enable quick and convenient access to


• A protecting insect screen may be installed as
an option (DPV 200x300 s).
concealed equipment and utility lines.
• Suitable for high-humidity areas. Mounting
• Protected by national patents worldwide. • Easy mounting using mortar or glue.
• Universal mountings for left or right-side
Design opening.
• Made of high-quality ABS plastic. • Easy servicing.

Plastic access doors opening


from either side

Dimensions

Dimensions [mm]
Model
H B H1 B1 H2 L1 L B2
DPV 200x300 317 217 273 173 296 6.5 19.5 196

Color options

White Beige Grey Sky Blue Beige Marble Grey Marble Blue Marble Green Marble

390 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


ACCESS DOORS

DZ series Application Mounting


• Designed for wall or ceiling application. • Easy mounting using mortar or glue.

• Enable quick and convenient access to • Universal mountings for left or right-side
concealed equipment and utility lines. opening.

• Suitable for high-humidity areas. • Easy servicing.

• Protected by national patents worldwide.

Design
• Made of high-quality ABS plastic.
• Left or right-side opening.
• Equipped with a key lock.

Sample installations
Plastic access doors
with key lock

Dimensions

Dimensions [mm]
Model
H B H1 B1 H2 L1 L B2
DZ 150x300 317 167 273 123 297 5 25 147
DZ 250x400 417 267 373 223 397 5 25 247
DZ 300x500 517 317 473 273 497 5 25 297
DZ 300x600 617 317 573 273 597 5 25 297
DZ 400x500 517 417 473 373 497 5 25 397
DZ 400x600 617 417 573 373 597 5 25 397

Color options

White Beige Grey Sky Blue Beige Marble Grey Marble Blue Marble Green Marble

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 391


ACCESS DOORS

DD series Application • Left or right-side opening.

• Designed for wall or ceiling application.


• Press gently to open and close.

• Enable quick and convenient access to


• A wide range of sizes.
concealed equipment and utility lines.
Mounting
• Concealed mounting for esthetic appearance.
• Easy mounting using mortar or glue.
• Suitable for high-humidity areas.
• Universal mountings for left or right-side
• Protected by national patents worldwide. opening.
• Double-sided hinges.
Design
• Easy servicing.
• Made of high-quality ABS plastic.
• The door surface is ready for acrylic and water-
dispersion paint or wallpaper application.

Sample installations

Plastic access doors with


double-sided hinges and
paint-ready surface

Dimensions

Dimensions [mm]
Model
H B H1 B1 H2 L1 L B2
DD 200x300 336 236 291 189 297 3 20 197

Color options

White Beige Grey Sky Blue Beige Marble Grey Marble Blue Marble Green Marble

392 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


ACCESS DOORS

DM series Application • Left or right-side opening.

• Designed for wall application.


• Equipped with a magnetic latch for convenient
opening and closing by gentle pressure.
• Enable quick and convenient access to
• A wide range of sizes.
concealed equipment and utility lines.
• Suitable for high-humidity areas.
• Custom sizes are available upon request.

Mounting
• Protected by national patents worldwide.
• Easy mounting using mortar or glue.
Design • Universal mountings for left or right-side
• Made of high-quality steel with a durable opening.
powder coating.
• Easy servicing.
• The use of zinc phosphate compound ensures
100  % coating integrity and provides a reliable
corrosion protection.

Dimensions
Metal access doors Dimensions [mm]
Model
H B H1 B2 H2 B1 L
DM 100x100 136.5 136.5 96.5 98.1 98.1 96.5 25
DM 150x150 186.5 186.5 146.5 148.1 148.1 146.5 25
DM 150x200 236.5 186.5 196.5 148.1 198.1 146.5 25
DM 150x250 286.5 186.5 246.5 148.1 248.1 146.5 25
DM 150x300 336.5 186.5 296.5 148.1 298.1 146.5 25
DM 200x200 236.5 236.5 196.5 198.1 198.1 196.5 25
DM 200x250 286.5 236.5 246.5 198.1 248.1 196.5 25
DM 200x300 336.5 236.5 296.5 198.1 298.1 196.5 25
DM 200x350 386.5 236.5 346.5 198.1 348.1 196.5 25
DM 200x400 436.5 236.5 396.5 198.1 398.1 196.5 25
DM 200x500 536.5 236.5 496.5 198.1 498.1 196.5 25
DM 225x300 336.5 261.5 296.5 223.1 298.1 221.5 25
Magnetic latch DM 225x590 626.5 261.5 586.5 223.1 588.1 221.5 25
DM 250x250 286.5 286.5 246.5 248.1 248.1 246.5 25
DM 250x300 336.5 286.5 296.5 248.1 298.1 246.5 25
DM 250x350 386.5 286.5 346.5 248.1 348.1 246.5 25
DM 250x400 436.5 286.5 396.5 248.1 398.1 246.5 25
DM 250x450 486.5 286.5 446.5 248.1 448.1 246.5 25
DM 300x200 236.5 336.5 196.5 298.1 198.1 296.5 25
DM 300x300 336.5 336.5 296.5 298.1 298.1 296.5 25
DM 300x400 436.5 336.5 396.5 298.1 398.1 296.5 25
DM 300x500 536.5 336.5 496.5 298.1 498.1 296.5 25
DM 300x600 636.5 336.5 596.5 298.1 598.1 296.5 25
DM 350x350 386.5 386.5 346.5 348.1 348.1 346.5 25
DM 400x400 436.5 436.5 396.5 398.1 398.1 396.5 25
DM 400x500 536.5 436.5 496.5 398.1 498.1 396.5 25
DM 400x600 636.5 436.5 596.5 398.1 598.1 396.5 25
DM 450x250 286.5 486.5 246.5 448.1 248.1 446.5 25
DM 450x450 486.5 486.5 446.5 448.1 448.1 446.5 25
DM 500x500 536.5 536.5 496.5 498.1 498.1 496.5 25
DM 500x600 636.5 536.5 596.5 498.1 598.1 496.5 25
DM 500x800 836.5 536.5 796.5 498.1 798.1 496.5 25
DM 555x555 591.5 591.5 551.5 553.1 553.1 551.5 25
DM 600x400 436.5 636.5 396.5 598.1 398.1 596.5 25
DM 600x600 636.5 636.5 596.5 598.1 598.1 596.5 25
DM 600x800 836.5 636.5 796.5 598.1 798.1 596.5 25

Color options

White Beige Brown Grey Sky Blue Black

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 393


DMZ series Application • Left or right-side opening.

• Designed for wall or ceiling application.


• Equipped with a key lock.

• Enable quick and convenient access to


• A wide range of sizes.
concealed equipment and utility lines. • Custom sizes are available upon request.

• Suitable for high-humidity areas.


Mounting
• Protected by national patents worldwide. • Easy mounting using mortar or glue.

Design
• Universal mountings for left or right-side
opening.
• Made of high-quality steel with a durable • Easy servicing.
powder coating.
• The use of zinc phosphate compound ensures
100  % coating integrity and provides a reliable
corrosion protection.

Dimensions
Metal access doors Dimensions [mm]
Model
H B H1 B2 H2 B1 L
DMZ 100x100 136.5 136.5 96.5 98.1 98.1 96.5 25
DMZ 150x150 186.5 186.5 146.5 148.1 148.1 146.5 25
DMZ 150x200 236.5 186.5 196.5 148.1 198.1 146.5 25
DMZ 150x250 286.5 186.5 246.5 148.1 248.1 146.5 25
DMZ 150x300 336.5 186.5 296.5 148.1 298.1 146.5 25
DMZ 200x200 236.5 236.5 196.5 198.1 198.1 196.5 25
DMZ 200x250 286.5 236.5 246.5 198.1 248.1 196.5 25
DMZ 200x300 336.5 236.5 296.5 198.1 298.1 196.5 25
DMZ 200x350 386.5 236.5 346.5 198.1 348.1 196.5 25
DMZ 200x400 436.5 236.5 396.5 198.1 398.1 196.5 25
DMZ 200x500 536.5 236.5 496.5 198.1 498.1 196.5 25
DMZ 225x300 336.5 261.5 296.5 223.1 298.1 221.5 25
Key lock DMZ 225x590 626.5 261.5 586.5 223.1 588.1 221.5 25
DMZ 250x250 286.5 286.5 246.5 248.1 248.1 246.5 25
DMZ 250x300 336.5 286.5 296.5 248.1 298.1 246.5 25
DMZ 250x350 386.5 286.5 346.5 248.1 348.1 246.5 25
DMZ 250x400 436.5 286.5 396.5 248.1 398.1 246.5 25
DMZ 250x450 486.5 286.5 446.5 248.1 448.1 246.5 25
DMZ 300x200 236.5 336.5 196.5 298.1 198.1 296.5 25
DMZ 300x300 336.5 336.5 296.5 298.1 298.1 296.5 25
DMZ 300x400 436.5 336.5 396.5 298.1 398.1 296.5 25
DMZ 300x500 536.5 336.5 496.5 298.1 498.1 296.5 25
DMZ 300x600 636.5 336.5 596.5 298.1 598.1 296.5 25
DMZ 350x350 386.5 386.5 346.5 348.1 348.1 346.5 25
DMZ 400x400 436.5 436.5 396.5 398.1 398.1 396.5 25
DMZ 400x500 536.5 436.5 496.5 398.1 498.1 396.5 25
DMZ 400x600 636.5 436.5 596.5 398.1 598.1 396.5 25
DMZ 450x250 286.5 486.5 246.5 448.1 248.1 446.5 25
DMZ 450x450 486.5 486.5 446.5 448.1 448.1 446.5 25
DMZ 500x500 536.5 536.5 496.5 498.1 498.1 496.5 25
DMZ 500x600 636.5 536.5 596.5 498.1 598.1 496.5 25
DMZ 500x800 836.5 536.5 796.5 498.1 798.1 496.5 25
DMZ 555x555 591.5 591.5 551.5 553.1 553.1 551.5 25
DMZ 600x400 436.5 636.5 396.5 598.1 398.1 596.5 25
DMZ 600x600 636.5 636.5 596.5 598.1 598.1 596.5 25
DMZ 600x800 836.5 636.5 796.5 598.1 798.1 596.5 25

Color options

White Beige Brown Grey Sky Blue Black

394 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


ACCESS DOORS

DMR series Application corrosion protection.

• Designed for wall application.


• Left or right-side opening.

• Enable quick and convenient access to


• Equipped with a plastic handle for easy
opening and closing.
concealed equipment and utility lines.
• Suitable for high-humidity areas.
• A wide range of sizes.

• Protected by national patents worldwide.


• Custom sizes are available upon request.

Mounting
Design
• Easy mounting using mortar or glue.
• Made of high-quality steel with a durable • Universal mountings for left or right-side
powder coating. opening.
• The use of zinc phosphate compound ensures • Easy servicing.
100  % coating integrity and provides a reliable

Dimensions

Metal access doors Dimensions [mm]


with a plastic handle Model
H B H1 B2 H2 B1 L
DMR 100x100 136.5 136.5 96.5 98.1 98.1 96.5 25
DMR 150x150 186.5 186.5 146.5 148.1 148.1 146.5 25
DMR 150x200 236.5 186.5 196.5 148.1 198.1 146.5 25
DMR 150x250 286.5 186.5 246.5 148.1 248.1 146.5 25
DMR 150x300 336.5 186.5 296.5 148.1 298.1 146.5 25
DMR 200x200 236.5 236.5 196.5 198.1 198.1 196.5 25
DMR 200x250 286.5 236.5 246.5 198.1 248.1 196.5 25
DMR 200x300 336.5 236.5 296.5 198.1 298.1 196.5 25
DMR 200x350 386.5 236.5 346.5 198.1 348.1 196.5 25
DMR 200x400 436.5 236.5 396.5 198.1 398.1 196.5 25
DMR 225x300 336.5 261.5 296.5 223.1 298.1 221.5 25
DMR 225x590 626.5 261.5 586.5 223.1 588.1 221.5 25
DMR 250x250 286.5 286.5 246.5 248.1 248.1 246.5 25
DMR 250x300 336.5 286.5 296.5 248.1 298.1 246.5 25
Plastic handle provides
DMR 250x350 386.5 286.5 346.5 248.1 348.1 246.5 25
additional convenience while opening
and closing DMR 250x400 436.5 286.5 396.5 248.1 398.1 246.5 25
DMR 250x450 486.5 286.5 446.5 248.1 448.1 246.5 25
DMR 300x200 236.5 336.5 196.5 298.1 198.1 296.5 25
DMR 300x300 336.5 336.5 296.5 298.1 298.1 296.5 25
DMR 300x400 436.5 336.5 396.5 298.1 398.1 296.5 25
DMR 300x500 536.5 336.5 496.5 298.1 498.1 296.5 25
DMR 300x600 636.5 336.5 596.5 298.1 598.1 296.5 25
DMR 350x350 386.5 386.5 346.5 348.1 348.1 346.5 25
DMR 400x400 436.5 436.5 396.5 398.1 398.1 396.5 25
DMR 400x500 536.5 436.5 496.5 398.1 498.1 396.5 25
DMR 400x600 636.5 436.5 596.5 398.1 598.1 396.5 25
DMR 450x250 286.5 486.5 246.5 448.1 248.1 446.5 25
DMR 450x450 486.5 486.5 446.5 448.1 448.1 446.5 25
DMR 500x500 536.5 536.5 496.5 498.1 498.1 496.5 25
DMR 500x600 636.5 536.5 596.5 498.1 598.1 496.5 25
DMR 500x800 836.5 536.5 796.5 498.1 798.1 496.5 25
DMR 555x555 591.5 591.5 551.5 553.1 553.1 551.5 25
DMR 600x400 436.5 636.5 396.5 598.1 398.1 596.5 25
DMR 600x600 636.5 636.5 596.5 598.1 598.1 596.5 25
DMR 600x800 836.5 636.5 796.5 598.1 798.1 596.5 25

Color options

White Beige Brown Grey Sky Blue Black

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 395


ACCESS DOORS

DMV series Application • Ventilation openings supply additional air into


the space behind the door.
• Designed for wall application.
• Left or right-side opening.
• Enable quick and convenient access to
• Equipped with a plastic handle for easy
concealed equipment and utility lines.
opening and closing.
• Suitable for high-humidity areas.
• A wide range of sizes.
• Protected by national patents worldwide.
• Custom sizes are available upon request.

Design Mounting
• Made of high-quality steel with a durable • Easy mounting using mortar or glue.
powder coating. • Universal mountings for left or right-side
• The use of zinc phosphate compound ensures opening.
100  % coating integrity and provides a reliable • Easy servicing.
corrosion protection.

Dimensions
Metal access doors
with ventilation openings Dimensions [mm]
Model
H B H1 B2 H2 B1 L
DMV 100x100 136.5 136.5 96.5 98.1 98.1 96.5 25
DMV 150x150 186.5 186.5 146.5 148.1 148.1 146.5 25
DMV 150x200 236.5 186.5 196.5 148.1 198.1 146.5 25
DMV 150x250 286.5 186.5 246.5 148.1 248.1 146.5 25
DMV 150x300 336.5 186.5 296.5 148.1 298.1 146.5 25
DMV 200x200 236.5 236.5 196.5 198.1 198.1 196.5 25
DMV 200x250 286.5 236.5 246.5 198.1 248.1 196.5 25
DMV 200x300 336.5 236.5 296.5 198.1 298.1 196.5 25
DMV 200x350 386.5 236.5 346.5 198.1 348.1 196.5 25
DMV 200x400 436.5 236.5 396.5 198.1 398.1 196.5 25
DMV 225x300 336.5 261.5 296.5 223.1 298.1 221.5 25
DMV 225x590 626.5 261.5 586.5 223.1 588.1 221.5 25
DMV 250x250 286.5 286.5 246.5 248.1 248.1 246.5 25
DMV 250x300 336.5 286.5 296.5 248.1 298.1 246.5 25
DMV 250x350 386.5 286.5 346.5 248.1 348.1 246.5 25
DMV 250x400 436.5 286.5 396.5 248.1 398.1 246.5 25
DMV 250x450 486.5 286.5 446.5 248.1 448.1 246.5 25
DMV 300x200 236.5 336.5 296.5 298.1 198.1 196.5 25
DMV 300x300 336.5 336.5 296.5 298.1 298.1 296.5 25
DMV 300x400 436.5 336.5 396.5 298.1 398.1 296.5 25
DMV 300x500 536.5 336.5 496.5 298.1 498.1 296.5 25
DMV 300x600 636.5 336.5 596.5 298.1 598.1 296.5 25
DMV 350x350 386.5 386.5 346.5 348.1 348.1 346.5 25
DMV 400x400 436.5 436.5 396.5 398.1 398.1 396.5 25
DMV 400x500 536.5 436.5 496.5 398.1 498.1 396.5 25
DMV 400x600 636.5 436.5 596.5 398.1 598.1 396.5 25
DMV 450x250 286.5 486.5 446.5 448.1 248.1 246.5 25
DMV 450x450 486.5 486.5 446.5 448.1 448.1 446.5 25
DMV 500x500 536.5 536.5 496.5 498.1 498.1 496.5 25
DMV 500x600 636.5 536.5 596.5 498.1 598.1 496.5 25
DMV 500x800 836.5 536.5 796.5 498.1 798.1 496.5 25
DMV 555x555 591.5 591.5 551.5 553.1 553.1 551.5 25
DMV 600x400 436.5 636.5 596.5 598.1 398.1 396.5 25
DMV 600x600 636.5 636.5 596.5 598.1 598.1 596.5 25
DMV 600x800 836.5 636.5 596.5 598.1 798.1 796.5 25

Color options

White Beige Brown Grey Sky Blue Black

396 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


ACCESS DOORS

DKP series Application • Metal plate for attaching ceramic tiles.

• Designed for wall installation and ceramic tile • Magnetic attachment of plate to the frame.
attachment. • Press gently to open and close or use a cup
plunger.
• Enable quick and convenient access to
concealed equipment and utility lines. • A wide range of sizes.

• Concealed mounting for esthetic appearance.


Mounting
• Suitable for high-humidity areas.
• Easy installation using spacers lugs.
• Protected by national patents worldwide.
• Height-adjustable magnets enable perfect
leveling of tiles to the wall surface.
Design
• Ceramic tiles are easily glued to the plate.
• The PVC profile frame contains magnets and • Easy servicing.
hides the tile-to-tile gap.

Access doors on a PVC frame


for attaching ceramic tiles

Sample installations

Dimensions

Dimensions [mm]
Model
B H B2 H2 B1 H1 L
DKP 150x150 156 156 145 145 153 153 30
DKP 150x200 156 206 145 195 153 203 30
DKP 150x300 156 306 145 295 153 303 30
DKP 200x200 206 206 195 195 203 203 30
DKP 200x250 206 256 195 245 203 253 30
DKP 200x300 206 306 195 295 203 303 30
DKP 200x350 206 356 195 345 203 353 30
DKP 200x400 206 406 195 395 203 403 30
DKP 200x450 206 456 195 445 203 453 30
DKP 200x500 206 506 195 495 203 503 30
DKP 250x250 256 256 245 245 253 253 30
DKP 250x300 256 306 245 295 253 303 30
DKP 250x350 256 356 245 345 253 353 30
DKP 250x400 256 406 245 395 253 403 30
DKP 300x300 306 306 295 295 303 303 30
DKP 300x350 306 356 295 345 303 353 30
DKP 300x400 306 406 295 395 303 403 30
DKP 300x450 306 456 295 445 303 453 30
DKP 300x500 306 506 295 495 303 503 30
DKP 400x400 406 406 395 395 403 403 30

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 397


ACCESS DOORS

DKM series Application • Metal plate for attaching ceramic tiles.

• Designed for wall installation and ceramic tile • Magnetic attachment of plate to the frame.
attachment. • Press gently to open and close or use a cup
plunger.
• Enable quick and convenient access to
concealed equipment and utility lines. • A wide range of sizes.

• Concealed mounting for esthetic appearance.


Mounting
• Suitable for high-humidity areas.
• Easy installation using mounting foam or
• Protected by national patents worldwide. mortar.
• Height-adjustable magnets enable perfect
Design leveling of tiles to the wall surface.
• The metal frame contains magnets for plate • Ceramic tiles are easily glued to the plate.
attachment and hides the tile-to-tile gap. • Easy servicing.

Sample Installations
Access doors on a metal frame recessed
for ceramic tiles

Dimensions

Dimensions [mm]
Model
B H B2 H2 L
DKM 150x150 163.6 163.6 150 150 26
DKM 150x200 163.6 213.6 150 200 26
DKM 150x250 163.6 263.6 150 250 26
DKM 150x300 163.6 313.6 150 300 26
DKM 200x200 213.6 213.6 200 200 26
DKM 200x250 213.6 263.6 200 250 26
DKM 200x300 213.6 313.6 200 300 26
DKM 200x350 213.6 363.6 200 350 26
DKM 200x400 213.6 413.6 200 400 26
DKM 200x450 213.6 463.6 200 450 26
DKM 200x500 213.6 513.6 200 500 26
DKM 250x250 263.6 263.6 250 250 26
DKM 250x300 263.6 313.6 250 300 26
DKM 250x350 263.6 363.6 250 350 26
DKM 250x400 263.6 413.6 250 400 26
DKM 300x300 313.6 313.6 300 300 26
DKM 300x350 313.6 363.6 300 350 26
DKM 300x400 313.6 413.6 300 400 26
DKM 300x450 313.6 463.6 300 450 26
DKM 300x500 313.6 513.6 300 500 26
DKM 400x400 413.6 413.6 400 400 26
DKM 400x500 413.6 513.6 400 500 26
DKM 500x500 513.6 513.6 500 500 26
DKM 600x600 613.6 613.6 600 600 26

398 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


ACCESS DOORS

DG series Application • Left or right-side opening.

• Designed for plasterboard walls and ceilings • Press gently to open and close.
12.5 and 15 mm thick. • A wide range of sizes.

• Enable quick and convenient access to • Custom sizes are available upon request.
concealed equipment and utility lines.
Mounting
• Suitable for high-humidity areas.
• Protected by national patents worldwide. • The doors are attached to aluminum profiles
on self-tapping screws and flushed up with
plasterboard on the front.
Design
• Universal mountings for left or right-side
• The main structural frame and panel frame are opening.
made of aluminum profile. • Easy servicing.
• The special mechanism ensures secure locking,
large-size doors are equipped with double locks.

Sample Installations
Access doors for plasterboard
application

Dimensions

Dimensions [mm]
Model
H/B H1/B1 B2 L L1 Number of locks
DG 200x200 260 196 204 15 55 1
DG 300x300 360 296 304 15 55 1
The special mechanism provides
for secure locking DG 400x400 460 396 404 15 55 2
DG 500x500 560 496 504 15 55 2
DG 600x600 660 596 604 15 55 2

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 399


ACCESS DOORS

DPM series Application • Easy opening and closing with a slight


pressing.
• Designed for ceiling application.
• Custom sizes are available upon request.
• Enable quick and convenient access to
• The doors are equipped with a galvanized
concealed equipment and utility lines.
steel safety rope with a snap hook to retain doors
• Suitable for high-humidity areas. in a position that enables inspection works.
• Protected by national patents worldwide. • The door opening angle with a safety rope is
45°.
Design • Open the snap hook if a wider opening angle
is required for inspections.
• Made of high-quality durable polymer-coated
steel. • The doors are lined with a sealant for tight
connection between the doors and the frame.
• The use of zinc phosphate compound
ensures 100  % coating integrity and provides a
Mounting
reliable corrosion protection.
• Specially designed mechanical lock provides a • Screw fixation to the ceiling-mounted
aluminium shape.
safe door fixation.

Access metal doors for


ceiling mounting

Dimensions

Dimensions [mm]
Model
 B  B1  H H1
DPM 300x300 336.5 296.5 298 200

400 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


VENTS. Domestic ventilation. Catalogue №6 | 02-2020 401
PLASTIC HVAC GRILLES

Profiplast means ideal air flows distribution

Quality and functionality of ventilation and air conditioning depends a lot on end air distribution, supply and intake devices.
Profiplast are the professional air distribution systems with a great product variety to implement any technical and project designs that are featured with
extreme durability.
The benefits of Profiplast products are due to the use of specially designed plastics . These offer the following advantages to consumers: Profiplast grilles
produce no condensation, have excellent sound-insulating and corrosion-resistant properties. Moreover they are non-flammable and are easy to paint.

Plastic properties
Generally, plastic is the most widely used construction material due to the beneficial properties:
· Durability combined with a maintenance-free service life
· Extremely low heat conductivity and good sound insulation
· UV-resistance
· Good hygienic properties and easy to clean
· Detergent resistant
· The best balance of price and quality
· Corrosion- and decay-resistance
· Eco-friendly because it is 100 % recyclable

The goods made of specially designed plastic:


· Prevent fire propagation because of their flame-proof qualities and have high fire safety properties.
· Totally recyclable at the end of the service life to get new products.
· Offer the best combination of price and quality.
The specially designed plastic is widely used for all plastic technologies and its application range is very comprehensive. There is no other comparable
material that is as usable and reliable for this application as Profiplast plastic. The specially designed plastic is the ideal solution for any application requiring low
maintenance, good sound insulation, consistent use, heavy operation load, ease of servicing, low flammability and high eco requirements.
These properties make plastic the best solution for premises with high hygiene standards.

402 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Supply and exhaust NHN (NUN) series grilles page
404

Supply and exhaust NVN (NUN) series grilles page


406

Exhaust GR series grilles page


408

Supply and exhaust RD series grilles page


410

Supply and exhaust ND series grilles page


412

Supply and exhaust NK-3 series grilles page


414

Supply and exhaust NK-4 series grilles page


416

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 403


SUPPLY AND EXTRACT GRILLES

NHN (NUN) Application


series • Supply and exhaust ventilation, heating and air conditioning
networks in industrial, commercial and domestic premises.

Design
• Made of high-quality plastic.
• Weather- and temperature-resistant.
• Removable spring-loaded vanes for simple maintenance.
• Simple and quick mounting.

Colour modifications

Ventilation grille with unregulated


white brown grey beige
vertical inclined vanes

UV-resistant Waterproof Heat-resistant Frostproof Easy mounting Fire-resistant Antibacterial Impact-resistant Durable Maintenance-free

Air flow distribution

Pressure loss and sound power diagram

100
Pressure, ΔP [Pa]

80
Pa
60
50 dBA
40
30

20

10
8
6
5
4
3
2 3 4 5 6 7 8 9 10
Speed, V [m/s]

404 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Overall dimensions

Dimensions [mm]
Model Air pass [m2]
H L h l
NUN 200×200 214 214 200 200 0.0066
NHN 300×200 214 303 200 289 0.0104
NHN 350×200 214 363 200 349 0.0131
NHN 400×200 214 392 200 378 0.0143
NHN 450×200 214 452 200 438 0.0170
NHN 500×200 214 512 200 498 0.0196
NHN 600×200 214 602 200 588 0.0235
NUN 300×300 303 303 289 289 0.0169
NHN 350×300 303 363 289 349 0.0212
NHN 400×300 303 392 289 378 0.0232
NHN 450×300 303 452 289 438 0.0275
NHN 500×300 303 512 289 498 0.0317
NHN 600×300 303 602 289 588 0.0381
NUN 350×350 363 363 349 349 0.0267
NHN 400×350 363 392 349 378 0.0292
NHN 450×350 363 452 349 438 0.0346
NHN 500×350 363 512 349 498 0.0399
NHN 600×350 363 602 349 588 0.0480
NUN 400×400 392 392 378 378 0.0321
NHN 450×400 392 452 378 438 0.0380
NHN 500×400 392 512 378 498 0.0439
NHN 600×400 392 602 378 588 0.0527
NUN 450×450 452 452 438 438 0.0451
NHN 500×450 452 512 438 498 0.0521
NHN 600×450 452 602 438 588 0.0626
NUN 500×500 512 512 498 498 0.0603
NHN 600×500 512 602 498 588 0.0724

Dimensions [mm]
Model Air pass [m2]
H L h l
NUN 580×580 599 599 585 585 0.0755
NUN 600×600 602 602 588 588 0.0764
NHN 900×200 214 912 200 898 0.0341
NHN 900×300 303 912 289 898 0.0553
NHN 900×350 363 912 349 898 0.0696
NHN 900×400 392 912 378 898 0.0765
NHN 900×450 452 912 438 898 0.0909
NHN 900×500 512 912 498 898 0.1052
NHN 900×600 602 912 588 898 0.1266

Dimensions [mm]
Model Air pass [m2]
H L h l
NHN 1200×300 303 1214 289 1200 0.0719
NHN 1200×350 363 1214 349 1200 0.0906
NHN 1200×400 392 1214 378 1200 0.0996
NHN 1200×450 452 1214 438 1200 0.1182
NHN 1200×500 512 1214 498 1200 0.1369
NHN 1200×600 602 1214 588 1200 0.1648
NHN 1350×300 303 1364 289 1350 0.0825
NHN 1350×350 363 1364 349 1350 0.1039
NHN 1350×400 392 1364 378 1350 0.1143
NHN 1350×450 452 1364 438 1350 0.1357
NHN 1350×500 512 1364 498 1350 0.1570
NHN 1350×600 602 1364 588 1350 0.1891

Dimensions [mm]
Model Air pass [m2]
H L h l
NHN 1500×300 303 1514 289 1500 0.0884
NHN 1500×350 363 1514 349 1500 0.1113
NHN 1500×400 392 1514 378 1500 0.1224
NHN 1500×450 452 1514 438 1500 0.1453
NHN 1500×500 512 1514 498 1500 0.1683
NHN 1500×600 602 1514 588 1500 0.2027

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 405


SUPPLY AND EXTRACT GRILLES

NVN (NUN) Application


series • Supply and exhaust ventilation, heating and air conditioning networks in industrial,
commercial and domestic premises.

Design
• Made of high-quality plastic.
• Weather- and temperature-resistant.
• Removable spring-loaded vanes for simple maintenance.
• Simple and quick mounting.

Colour modifications

Ventilation grille with unregulated white brown grey beige


horizontal inclined vanes

UV-resistant Waterproof Heat-resistant Frostproof Easy mounting Fire-resistant Antibacterial Impact-resistant Durable Maintenance-free

Air flow distribution

Pressure loss and sound power diagram

100
Pressure, ΔP [Pa]

80
Pa
60
50 dBA
40
30

20

10
8
6
5
4
3
2 3 4 5 6 7 8 9 10
Speed, V [m/s]

406 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Overall dimensions

Dimensions [mm]
Model Air pass [m2]
H L h l
NUN 200×200 214 214 200 200 0.0066
NVN 300×200 214 303 200 289 0.0106
NVN 350×200 214 363 200 349 0.0134
NVN 400×200 214 392 200 378 0.0147
NVN 450×200 214 452 200 438 0.0174
NVN 500×200 214 512 200 498 0.0202
NVN 600×200 214 602 200 588 0.0243
NUN 300×300 303 303 289 289 0.0169
NVN 350×300 303 363 289 349 0.0213
NVN 400×300 303 392 289 378 0.0234
NVN 450×300 303 452 289 438 0.0278
NVN 500×300 303 512 289 498 0.0322
NVN 600×300 303 602 289 588 0.0387
NUN 350×350 363 363 349 349 0.0267
NVN 400×350 363 392 349 378 0.0293
NVN 450×350 363 452 349 438 0.0348
NVN 500×350 363 512 349 498 0.0402
NVN 600×350 363 602 349 588 0.0484
NUN 400×400 392 392 378 378 0.0321
NVN 450×400 392 452 378 438 0.0531
NVN 500×400 392 512 378 498 0.0441
NVN 600×400 392 602 378 588 0.0381
NUN 450×450 452 452 438 438 0.0451
NVN 500×450 452 512 438 498 0.0629
NVN 600×450 452 602 438 588 0.0522
NUN 500×500 512 512 498 498 0.0603
NVN 600×500 512 602 498 588 0.0726
NUN 580×580 599 599 585 585 0.0872
NUN 600×600 602 602 588 588 0.0862

Dimensions [mm]
Model Air pass [m2]
H L h l
NVN 900×200 214 934 200 920 0.0365
NVN 900×300 303 934 289 920 0.0581
NVN 1200×300 303 1234 289 1220 0.0800
NVN 900×350 363 934 349 920 0.0727
NVN 1200×350 363 1234 349 1220 0.1001
NVN 900×400 392 934 378 920 0.0798
NVN1200×400 392 1234 378 1220 0.1098
NVN 900×450 452 934 438 920 0.0944
NVN 1200×450 452 1234 438 1220 0.1299
NVN 900×500 512 934 498 920 0.1090
NVN 1200×500 512 1234 498 1220 0.1500
NVN 900×600 602 934 588 920 0.1309
NVN 1200×600 602 1234 588 1220 0.1801

Dimensions [mm]
Model Air pass [m2]
H L h l
NVN 1350×300 303 1377 289 1363 0.0857
NVN 1500×300 303 1559 289 1545 0.0989
NVN 1350×350 363 1377 349 1363 0.1072
NVN 1500×350 363 1559 349 1545 0.1238
NVN 1350×400 392 1377 378 1363 0.1176
NVN 1500×400 392 1559 378 1545 0.1358
NVN 1350×450 452 1377 438 1363 0.1391
NVN 1500×450 452 1559 438 1545 0.1606
NVN 1350×500 512 1377 498 1363 0.1606
NVN 1500×500 512 1559 498 1545 0.1854
NVN 1350×600 602 1377 588 1363 0.1928
NVN 1500×600 602 1559 588 1545 0.2227

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 407


SUPPLY AND EXTRACT GRILLES

GR Application
series • Exhaust ventilation, heating and air conditioning networks in industrial, commercial
and domestic premises.

Design
• Made of high-quality plastic.
• Weather- and temperature-resistant.
• Removable spring-loaded vanes for simple maintenance.
• Simple and quick mounting.

Colour modifications

Ventilation grille with white brown grey beige


gravity shutters

UV-resistant Waterproof Heat-resistant Frostproof Easy mounting Fire-resistant Antibacterial Impact-resistant Durable Maintenance-free

Air flow distribution


The shutters are closed
The shutters are
(protection against
opened
backdraft)

Pressure loss and sound power diagram

100
Pressure, ΔP [Pa]

80
Pa
60
50 dBA
40
30

20

10
8
6
5
4
3
2 3 4 5 6 7 8 9 10
Speed, V [m/s]

408 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Overall dimensions

Dimensions [mm]
Model Air pass [m2]
H L h l
GR 300×300 303 303 289 289 0.0543
GR 350×300 303 362 289 348 0.0677
GR 400×300 303 422 289 408 0.1013
GR 450×300 303 464 289 450 0.1132
GR 500×300 303 514 289 500 0.1530
GR 600×300 303 598 289 584 0.1816
GR 350×350 362 362 348 348 0.1512
GR 400×350 362 422 348 408 0.0813
GR 500×350 362 514 348 500 0.1022
GR 600×350 362 598 348 584 0.1212
GR 400×400 422 422 408 408 0.0813
GR 450×400 422 464 408 450 0.1132
GR 500×400 422 514 408 500 0.1274
GR 600×400 422 598 408 584 0.1816
GR 600×600 598 598 584 584 0.1816

Dimensions [mm]
Model Air pass [m2]
H L h l
GR 900×300 303 914 289 900 0.1882
GR 1200×300 303 1214 289 1200 0.2563
GR 900×350 362 914 348 900 0.2347
GR 1200×350 362 1214 348 1200 0.3196
GR 900×400 422 914 408 900 0.2819
GR 1200×400 422 1214 408 1200 0.3840
GR 900×600 598 914 584 900 0.4205
GR 1200×600 598 1214 584 1200 0.5727

Dimensions [mm]
Model Air pass [m2]
H L h l
GR 1350×300 303 1364 289 1350 0.2856
GR 1500×300 303 1514 289 1500 0.3197
GR 1350×350 362 1364 348 1350 0.3561
GR 1500×350 362 1514 348 1500 0.3986
GR 1350×400 422 1364 408 1350 0.4278
GR 1500×400 422 1514 408 1500 0.4788
GR 1350×600 598 1364 584 1350 0.6381
GR 1500×600 598 1514 584 1500 0.7142

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 409


SUPPLY AND EXTRACT GRILLES

RD Application
series • Supply and exhaust ventilation, heating and air conditioning networks in industrial,
commercial and domestic premises.

Design
• Made of high-quality plastic.
• Weather- and temperature-resistant.
• Simple and quick mounting.

Colour modifications

white brown grey beige transparent


Decorative ventilation grille

roof
tant Heat-resistant
Waterproof
UV-resistant Heat-resistant
Frostproof
Waterproof Easy
Frostproof
Heat-resistant
mounting Easy
Fire-resistant
mounting
Frostproof Fire-resistant
Antibacterial
Easy mounting Impact-resistant
Antibacterial
Fire-resistant Impact-resistant
Durable
Antibacterial Maintenance-free
Impact-resistant
Durable Maintenance-free
Durable Maintenance-free

Air flow distribution

Pressure loss and sound power diagram

100
Pressure, ΔP [Pa]

80
Pa
60
50 dBA
40
30

20

10
8
6
5
4
3
2 3 4 5 6 7 8 9 10
Speed, V [m/s]

410 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Overall dimensions

Dimensions [mm]
Model
L H b
RD 600/1 M 300 300 10
RD 600/2 M 600 300 10
RD 600 M 600 600 10
RD 600/6 M 600 900 10
RD 600/8 M 600 1200 10
RD 600/1 L 300 300 12
RD 600/2 L 600 300 12
RD 600 L 600 600 12
RD 600/6 L 600 900 12
RD 600/8 L 600 1200 12
RD 600/1 300 300 15
RD 600/2 600 300 15
RD 600 600 600 15
RD 600/6 600 900 15
RD 600/8 600 1200 15

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 411


SUPPLY AND EXTRACT GRILLES

ND Application
series • Supply and exhaust ventilation, heating and air conditioning networks in industrial,
commercial and domestic premises.

Design
• Made of high-quality plastic.
• Weather- and temperature-resistant.
• Simple and quick mounting.

Colour modifications

white brown grey beige


Decorative ventilation grille

UV-resistant Waterproof Heat-resistant Frostproof Easy mounting Fire-resistant Antibacterial Impact-resistant Durable Maintenance-free

Air flow distribution

Pressure loss and sound power diagram

100
Pressure, ΔP [Pa]

80
Pa
60
50 dBA
40
30

20

10
8
6
5
4
3
2 3 4 5 6 7 8 9 10
Speed, V [m/s]

412 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Overall dimensions

Dimensions [mm]
Model Air pass [m2]
H L h l
ND 350×350 362 362 348 348 0.0729
ND 650×350 362 660 348 646 0.1458
ND 950×350 362 958 348 944 0.2187
ND 1250×350 362 1256 348 1242 0.2916
ND 650×650 660 660 646 646 0.2916
ND 950×650 660 958 646 944 0.4374
ND 1250×650 660 1256 646 1242 0.5832

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 413


SUPPLY AND EXTRACT GRILLES

NK-3 Application
series • Supply and exhaust ventilation, heating and air conditioning networks in industrial,
commercial and domestic premises.

Design
• Made of high-quality plastic.
• Weather- and temperature-resistant.
• Removable spring-loaded vanes for simple maintenance.
• Simple and quick mounting.
• Uniform air flow distribution.

Ventilation combined grille


with unregulated vanes Colour modifications

white brown grey beige

UV-resistant Waterproof Heat-resistant Frostproof Easy mounting Fire-resistant Antibacterial Impact-resistant Durable Maintenance-free

Air flow distribution

NK H2V1 NK H1V2

Pressure loss and sound power diagram

100
Pressure, ΔP [Pa]

80
Pa
60
50 dBA
40
30

20

10
8
6
5
4
3
2 3 4 5 6 7 8 9 10
Speed, V [m/s]

414 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Overall dimensions

Dimensions [mm]
Model Air pass [m2]
H L h l
NVNK H1V1 580×580 598 598 584 584 0.0755

Dimensions [mm]
Model Air pass [m2]
H L h l
NK H2V1 1200×600 602 1214 588 1200 0.1718
NK H2V1 1350×600 602 1364 588 1350 0.1966
NK H2V1 1500×600 602 1514 588 1500 0.2213

Dimensions [mm]
Model Air pass [m2]
H L h l
NK H1V2 900×300 303 929 289 915 0.0562
NK H1V2 1200×300 303 1214 289 1200 0.9069
NK H1V2 900×400 392 929 378 915 0.0774
NK H1V2 1200×400 392 1214 378 1200 0.1064
NK H1V2 900×600 602 929 588 915 0.1273
NK H1V2 1200×600 602 1214 588 1200 0.1750
NK H1V2 1350×600 602 1364 588 1350 0.2002
NK H1V2 1500×600 602 1514 588 1500 0.2253

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 415


SUPPLY AND EXTRACT GRILLES

NK-4 Application
series • Supply and exhaust ventilation, heating and air conditioning networks in industrial,
commercial and domestic premises.

Design
• Made of high-quality plastic.
• Weather- and temperature-resistant.
• Removable spring-loaded vanes for simple maintenance.
• Simple and quick mounting.
• Uniform air flow distribution.

Colour modifications

Ventilation combined grille


with unregulated vanes white brown grey beige

UV-resistant Waterproof Heat-resistant Frostproof Easy mounting Fire-resistant Antibacterial Impact-resistant Durable Maintenance-free

Air flow distribution

Pressure loss and sound power diagram

100
Pressure, ΔP [Pa]

80
Pa
60
50 dBA
40
30

20

10
8
6
5
4
3
2 3 4 5 6 7 8 9 10
Speed, V [m/s]

416 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Overall dimensions

Dimensions [mm]
Model Air pass [m2]
H L h l
NK H2V2 550×550 570 570 556 556 0.0422
NK H2V2 600×600 630 630 616 616 0.0577
NK H2V2 900×600 630 930 616 619 0.0982

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 417


METAL GRILLES
FOR HVAC

ONG, ONV – single-row unregulated grilles page


420

ONL – single-row unregulated linear grilles page


422

ONF/ONFS – single-row unregulated grilles page


424

ONK – single-row unregulated sectional grilles page


426

ORG, ORV – single-row regulated grilles page


428

ORK – single-row regulated sectional grilles page


430

DR – double-row regulated grilles page


432

DP – ceiling diffusers page


434

DPp – ceiling diffusers page


436

418 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


DS – slit diffusers page
438

RP – perforated grilles page


440

RN – supply and exhaust ventilation grille page


442

RG – gravity grilles page


444

RGS – gravity grilles page


446

GRM – gravity grilles page


448

DVK – swirl diffusers page


450

DVP – swirl diffusers page


451

Additional accessories page


452

Grille fixation page


460

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 419


SUPPLY AND EXHAUST GRILLES

Series Application
ONG / ONV • Supply and exhaust ventilation, heating
and air conditioning networks in industrial,
commercial and domestic premises.

Design
• Made of high-quality extruded aluminium.

• Polymer or anodized grille coating


ensures weather-resistant properties.

• Non-standard sizes may be ordered.

Modifications
• Available modifications with an air flow regulator
(R) and an adapter (A) for connection to air ducts.

• Available modifications with versatile fixing (u)


or with special springs (p) for fast mounting.
Single-row ventilation grille with fixed vanes

ONV – vertical vane location ONG – horizontal vane location

Air flow distribution options

straight (0°) single-sided (15°) double-sided (2 x 15°)


ONG1, ONV1 ONG2, ONV2 ONG3, ONV3

Standard size [mm] and air pass [m2]


Length L [mm]
Height H [mm]
100 150 200 250 300 350 400

100 0.004 0.007 0.010 0.012 0.015 0.018 0.021

150 0.007 0.010 0.015 0.018 0.023 0.027 0.031

200 0.010 0.015 0.021 0.026 0.033 0.038 0.045

250 0.012 0.018 0.026 0.032 0.041 0.047 0.055

300 0.015 0.023 0.033 0.041 0.051 0.059 0.069

350 0.017 0.026 0.038 0.047 0.059 0.068 0.080

400 0.020 0.030 0.044 0.054 0.069 0.079 0.093

450 0.023 0.035 0.051 0.062 0.080 0.090 0.107

500 0.026 0.039 0.056 0.070 0.089 0.100 0.119

600 0.031 0.047 0.067 0.084 0.105 0.121 0.142

700 0.036 0.055 0.078 0.094 0.124 0.145 0.170

800 0.042 0.063 0.090 0.112 0.141 0.163 0.190

900 0.048 0.072 0.103 0.129 0.160 0.185 0.228

1000 0.053 0.079 0.113 0.141 0.177 0.204 0.239

420 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Pressure loss and sound power level
ΔP [Pa]
Calculation Correction factor K
– distributed air flow angle 0° formula
Sap [m2] 0.005 0.01 0.02 0.03 0.05 0.07 0.1
– distributed air flow angle 15° LWA = LWAO x K
K [dBA] –13 –9 –6 –4.5 –3 –1.5 0

Designation:
ΔP – pressure loss [Pa]
LWA – sound power level [dBA]
LWAO – sound power level for air pass 0.1 m2 [dBA]
K – correction factor for sound power level calculation depending on air pass [dBA]
Sap – air pass [m2]
V – rated speed [m/s]

ΔP f(V) [Pa] V [m/s]


Lwao [dBA]

Order code

LxH

Grille type: Grille coating:


ONG (ONV) – single-row unregulated grille with horizontal "___ " – colour* (white by default)
(vertical) vanes "Anodized"

Vane position: Accessories:


1 – direct (deflection angle 0°) ___ – no
2 – single-sided (deflection angle 15°) R – air flow regulator
3 – double-sided (deflection angle 15°) A – adapter
Grille size: Grille fixation:
L – length [mm] u – versatile
H – height [mm] p – spring

* Standard polymer coating colours:

white beige brown grey blue black


RAL 9016 RAL 1015 RAL 8017 RAL 7001 RAL 5005 RAL 9005

Overall and mounting dimensions

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 421


SUPPLY AND EXHAUST GRILLES

Series Application
ONL • Supply and exhaust ventilation, heating
and air conditioning networks in industrial,
commercial and domestic premises.

Design
• Made of high-quality extruded aluminium.

• Polymer or anodized grille coating


ensures weather-resistant properties.

• Non-standard sizes may be ordered.

Modifications
• Available modifications with an air flow regulator
(R) and an adapter (A) for connection to air ducts.
Single-row linear horizontal ventilation grille
with fixed vanes • Available modifications with versatile fixing (u)
or with special springs (p) for fast mounting.

Air flow distribution options

straight (0°) single-sided (15°) double-sided (2 x 15°)


ONL1 ONL2 ONL3

Standard size [mm] and air pass [m2]


Length L [mm]
Height H [mm]
400 450 500 550 600 650 700 750 800 850 900 950 1000
100 0.003 0.024 0.027 0.030 0.033 0.036 0.039 0.042 0.045 0.048 0.051 0.054 0.057
150 0.004 0.035 0.039 0.043 0.047 0.051 0.055 0.060 0.064 0.068 0.072 0.076 0.080
200 0.007 0.051 0.058 0.064 0.070 0.076 0.081 0.087 0.093 0.099 0.105 0.110 0.115
250 0.008 0.062 0.070 0.077 0.084 0.091 0.098 0.102 0.106 0.110 0.113 0.121 0.128
300 0.009 0.077 0.086 0.091 0.096 0.106 0.115 0.124 0.132 0.141 0.149 0.159 0.168
350 0.009 0.090 0.099 0.105 0.111 0.122 0.132 0.142 0.151 0.161 0.170 0.182 0.193
400 0.105 0.112 0.119 0.126 0.133 0.140 0.147 0.166 0.184 0.196 0.208 0.220 0.232
450 0.119 0.127 0.135 0.142 0.150 0.158 0.166 0.187 0.208 0.222 0.236 0.249 0.263
500 0.133 0.142 0.150 0.159 0.168 0.177 0.186 0.209 0.233 0.248 0.263 0.278 0.294
550 0.147 0.156 0.166 0.175 0.185 0.195 0.205 0.231 0.257 0.274 0.291 0.307 0.324
600 0.161 0.171 0.181 0.192 0.202 0.213 0.224 0.253 0.281 0.300 0.318 0.337 0.355
650 0.175 0.186 0.197 0.208 0.219 0.231 0.243 0.274 0.305 0.325 0.346 0.366 0.386
700 0.188 0.200 0.212 0.224 0.237 0.250 0.263 0.296 0.330 0.351 0.373 0.395 0.417
750 0.202 0.215 0.228 0.241 0.254 0.268 0.282 0.318 0.354 0.377 0.401 0.424 0.447
800 0.215 0.229 0.243 0.257 0.271 0.286 0.301 0.340 0.378 0.403 0.428 0.453 0.478
850 0.229 0.244 0.259 0.273 0.288 0.304 0.320 0.361 0.402 0.429 0.455 0.482 0.509
900 0.243 0.258 0.274 0.290 0.306 0.322 0.339 0.383 0.427 0.455 0.483 0.511 0.539
950 0.256 0.273 0.290 0.306 0.323 0.340 0.358 0.404 0.451 0.480 0.510 0.540 0.570
1000 0.270 0.288 0.305 0.323 0.340 0.359 0.377 0.426 0.475 0.506 0.537 0.569 0.600

422 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Pressure loss and sound power level
ΔP [Pa]
Calculation Correction factor K
– distributed air flow angle 0° formula
S [m2]
ap
0.01 0.02 0.05 0.1 0.2 0.4
– distributed air flow angle 15° LWA = LWAO x K
K [dBA] –9 –6 –3 0 +3 +6

Designation:
ΔP – pressure loss [Pa]
LWA – sound power level [dBA]
LWAO – sound power level for air pass 0.1 m2 [dBA]
K – correction factor for sound power level calculation depending on air pass [dBA]
Sap – air pass [m2]
V – rated speed [m/s]

ΔP f(V) [Pa] V [m/s]


Lwao [dBA]

Order code LxH

Grille type: Grille coating:


ONL – single-row linear ventilation grille with fixed vanes "___ " – colour* (white by default)
"Anodized"
Vane position: Accessories:
1 – direct (deflection angle 0°) ___ – no
2 – single-sided (deflection angle 15°) R – air flow regulator
3 – double-sided (deflection angle 15°) A – adapter
Grille size: Grille fixation:
L – length [mm] u – versatile
H – height [mm] p – spring

* Standard polymer coating colours:

white beige brown grey blue black


RAL 9016 RAL 1015 RAL 8017 RAL 7001 RAL 5005 RAL 9005

Overall and mounting dimensions

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 423


SUPPLY AND EXHAUST GRILLES

Series Application
ONF/ONFS • Supply and exhaust ventilation, heating
and air conditioning networks in industrial,
commercial and domestic premises.

Design
• Made of high-quality extruded aluminium.

• Polymer or anodized grille coating


ensures weather-resistant properties.

• Non-standard sizes may be ordered.

• Grilles above 450 mm are equipped with


a partition for extra rigidity (ONFS series).

Modifications
• Available modifications with an
adapter (A) for connection to air ducts.

Single-row horizontal ventilation grille with • Available modifications with special


fixed vanes springs (p) for fast mounting.

Air flow distribution

vane deflection
angle – 45°

Standard size [mm] and air pass [m2]

Length L [mm]
Height H [mm]
100 150 200 250 300 350 400 450 500 600 700 800 900 1000

100 0.004 0.007 0.010 0.012 0.015 0.018 0.021 0.024 0.027 0.033 0.039 0.045 0.051 0.057

150 0.007 0.010 0.015 0.018 0.023 0.027 0.031 0.035 0.039 0.047 0.055 0.064 0.072 0.080

200 0.010 0.015 0.021 0.026 0.033 0.038 0.045 0.051 0.058 0.070 0.081 0.093 0.105 0.115

250 0.012 0.018 0.026 0.032 0.041 0.047 0.055 0.062 0.070 0.084 0.098 0.106 0.113 0.128

300 0.015 0.023 0.033 0.041 0.051 0.059 0.069 0.077 0.086 0.096 0.115 0.132 0.149 0.168

350 0.017 0.026 0.038 0.047 0.059 0.068 0.080 0.090 0.099 0.111 0.132 0.151 0.170 0.193

400 0.020 0.030 0.044 0.054 0.069 0.079 0.093 0.103 0.117 0.142 0.166 0.189 0.212 0.237

450 0.023 0.035 0.051 0.062 0.080 0.090 0.107 0.117 0.131 0.160 0.186 0.214 0.239 0.265

500 0.026 0.039 0.056 0.070 0.089 0.100 0.119 0.130 0.145 0.178 0.206 0.238 0.265 0.293

600 0.031 0.047 0.067 0.084 0.105 0.121 0.142 0.158 0.173 0.214 0.246 0.287 0.318 0.349

700 0.036 0.055 0.078 0.094 0.124 0.145 0.170 0.184 0.203 0.251 0.288 0.336 0.372 0.408

800 0.042 0.063 0.090 0.112 0.141 0.163 0.190 0.211 0.232 0.288 0.330 0.385 0.426 0.467

900 0.048 0.072 0.103 0.129 0.160 0.185 0.228 0.238 0.262 0.325 0.372 0.435 0.481 0.527

1000 0.053 0.079 0.113 0.141 0.177 0.204 0.239 0.266 0.292 0.361 0.414 0.484 0.536 0.587

424 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Pressure loss and sound power level

ΔP [Pa] Calculation Correction factor K


formula
Sap [m2] 0.005 0.01 0.02 0.03 0.05 0.07 1
LWA = LWAO x K
K [dBA] –13 –9 –6 –4.5 –3 –1.5 0

Designation:
ΔP – pressure loss [Pa]
LWA – sound power level [dBA]
LWAO – sound power level for air pass 0.1 m2 [dBA]
K – correction factor for sound power level calculation depending on air pass [dBA]
Sap – air pass [m2]
V – rated speed [m/s]

V [m/s]
ΔP f(V) [Pa]
Lwao [dBA]

Order code

LxH

Grille coating:
"___ " – colour* (white by default)
"Anodized"

Grille type: Accessories:


ONF / ONFS – single-row unregulated grille with horizontal ___ – no
(vertical) vanes fixed at 45°
A – adapter

Grille size: Grille fixation:


L – length [mm] p – spring
H – height [mm]

* Standard polymer coating colours:

white beige brown grey blue black


RAL 9016 RAL 1015 RAL 8017 RAL 7001 RAL 5005 RAL 9005

Overall and mounting dimensions

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 425


SUPPLY AND EXHAUST GRILLES

Series Application
ONK • Supply and exhaust ventilation, heating
and air conditioning networks in industrial,
commercial and domestic premises.

Design
• Made of high-quality extruded aluminium.

• Equipped with a central cross-


type partition for extra rigidity.

• Polymer or anodized grille coating


ensures weather-resistant properties.

• Non-standard sizes may be ordered.

Modifications
• Available modifications with an air flow regulator
Single-row sectional ventilation grille with fixed vanes (R) and an adapter (A) for connection to air ducts.

• Available modifications with versatile


fixing (u) for fast mounting.

ONK2 – pair-wise and perpendicular ONK1, ONK3 – horizontal vane posi-


vane position tion

Air flow distribution options

straight (0°) single-sided (15°)


ONK1, ONK2 ONK3

Standard size [mm] and air pass [m2]


Length L [mm]
Height H [mm]
450 500 550 600 650 700 750 800 850 900 950 1000

450 0.117 0.131 0.146 0.160 0.173 0.186 0.200 0.214 0.226 0.239 0.252 0.265

500 0.130 0.145 0.162 0.178 0.192 0.206 0.222 0.238 0.252 0.265 0.279 0.293

550 0.144 0.159 0.178 0.196 0.211 0.226 0.244 0.263 0.277 0.292 0.306 0.321

600 0.158 0.173 0.194 0.214 0.230 0.246 0.267 0.287 0.303 0.318 0.334 0.349

650 0.171 0.188 0.210 0.233 0.250 0.267 0.289 0.312 0.328 0.345 0.362 0.379

700 0.184 0.203 0.227 0.251 0.270 0.288 0.312 0.336 0.354 0.372 0.390 0.408

750 0.198 0.217 0.243 0.270 0.289 0.309 0.335 0.361 0.380 0.399 0.418 0.438

800 0.211 0.232 0.260 0.288 0.309 0.330 0.358 0.385 0.406 0.426 0.447 0.467

850 0.225 0.247 0.277 0.306 0.329 0.351 0.380 0.410 0.432 0.453 0.475 0.497

900 0.238 0.262 0.293 0.325 0.348 0.372 0.403 0.435 0.458 0.481 0.504 0.527

950 0.252 0.277 0.310 0.343 0.368 0.393 0.426 0.459 0.484 0.508 0.533 0.557

1000 0.266 0.292 0.327 0.361 0.388 0.414 0.449 0.484 0.510 0.536 0.561 0.587

426 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Pressure loss and sound power level
ΔP [Pa]
Calculation Correction factor K
– distributed air flow angle 0° formula
Sap [m2] 0.01 0.15 0.2 0.3 0.4
– distributed air flow angle 15° LWA = LWAO x K
K [dBA] 0 +1.5 +3 +4.5 +6

Designation:
ΔP – pressure loss [Pa]
LWA – sound power level [dBA]
LWAO – sound power level for air pass 0.1 m2 [dBA]
K – correction factor for sound power level calculation depending on air pass [dBA]
Sap – air pass [m2]
V – rated speed [m/s]

ΔP f(V) [Pa] V [m/s]


Lwao [dBA]

Order code

LxH
Grille coating:
"___ " – colour* (white by default)
"Anodized"

Grille type:
ONK – single-row sectional grille with fixed vanes

Vane position: Accessories:


1 – direct (deflection angle 0°) ___ – no
2 – single-sided (deflection angle 15°) R – air flow regulator
3 – double-sided (deflection angle 15°) A – adapter
Grille size: Grille fixation:
L – length [mm] u – versatile
H – height [mm]

* Standard polymer coating colours:

white beige brown grey blue black


RAL 9016 RAL 1015 RAL 8017 RAL 7001 RAL 5005 RAL 9005

Overall and mounting dimensions

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 427


SUPPLY AND EXHAUST GRILLES

Series Application
ORG / ORV • Supply and exhaust ventilation, heating
and air conditioning networks in industrial,
commercial and domestic premises.

Design
• Made of high-quality extruded aluminium.

• Polymer or anodized grille coating


ensures weather-resistant properties.

• Non-standard sizes may be ordered.

Modifications
• Available modifications with an air flow regulator
(R) and an adapter (A) for connection to air ducts.

• Available modifications with versatile fixing (u)


or with special springs (p) for fast mounting.
Single-row ventilation grille
with adjustable louvres

ORG – horizontal position ORV – vertical position


of louvres of louvres

Standard size [mm] and air pass [m2]


Length L [mm]
Height H [mm]
100 150 200 250 300 350 400

100 0.002 0.008 0.014 0.018 0.023 0.027 0.033

150 0.005 0.011 0.017 0.021 0.026 0.030 0.036

200 0.008 0.018 0.025 0.031 0.040 0.045 0.054

250 0.010 0.021 0.032 0.038 0.048 0.055 0.066

300 0.013 0.027 0.041 0.051 0.062 0.071 0.084

350 0.016 0.031 0.046 0.057 0.073 0.081 0.096

400 0.019 0.037 0.055 0.068 0.087 0.100 0.114

450 0.022 0.042 0.062 0.077 0.098 0.112 0.132

500 0.024 0.047 0.069 0.085 0.109 0.125 0.144

600 0.029 0.056 0.083 0.102 0.131 0.149 0.175

700 0.034 0.066 0.098 0.120 0.154 0.175 0.205

800 0.038 0.075 0.112 0.138 0.177 0.201 0.235

900 0.043 0.085 0.127 0.156 0.20 0.227 0.266

1000 0.047 0.094 0.141 0.173 0.22 0.253 0.296

428 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Pressure loss and sound power level
ΔP [Pa]
Calculation Correction factor Kp
formula
0° 22° 45°
ΔPp = ΔP x Kp
Kp 1 1.25 1.5

Calculation Correction factor K


formula
Sap [m2] 0.01 0.02 0.05 0.1 0.2 0.4
LWA = LWAO x K
K [dBA] –9 –6 –3 0 +3 +6

Designation:
ΔPp – pressure loss at various vane positions [Pa]
ΔP – pressure loss [Pa]
Kp – correction factor for pressure loss calculation depending on louvre deflection
V [m/s] angle
ΔP f(V) [Pa] LWA – sound power level [dBA]
Lwao [dBA]
LWAO – sound power level for air pass 0.1 m2 [dBA]
K – correction factor for sound power level calculation depending on air pass [dBA]
Sap – air pass [m2]
V – rated speed [m/s]

Order code

LxH

Grille coating:
Grille type:
"___ " – colour* (white by default)
ORG – single-row grille with individually adjustable horizontal
"Anodized"
louvres
ORV – single-row grille with individually adjustable vertical Accessories:
louvres ___ – no
R – air flow regulator
A – adapter

Grille size: Grille fixation:


L – length [mm] u – versatile
H – height [mm] p – spring

* Standard polymer coating colours:

white beige brown grey blue black


RAL 9016 RAL 1015 RAL 8017 RAL 7001 RAL 5005 RAL 9005

Overall and mounting dimensions

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 429


SUPPLY AND EXHAUST GRILLES

Series Application
ORK • Supply and exhaust ventilation, heating and air
conditioning networks in industrial, commercial and
domestic premises.

Design
• Made of high-quality extruded aluminium.

• Air flow direction control.

• Cross-flow partition provides extra rigidity.

• Polymer or anodized grille coating ensures weather-


resistant properties.

• Non-standard sizes may be ordered.

Modifications
• Available modifications with an air flow regulator (R) and
an adapter (A) for connection to air ducts.

Single-row sectional ventilation grille with • Available modifications with versatile fixing (u) for fast

adjustable louvres mounting.

ORK1 – parallel louvre ORK2 – pairwise perpendicular


position louvre position

Standard size [mm] and air pass [m2]


Length L [mm]
Height H [mm]
450 500 550 600 650 700 750 800 850 900 950 1000

450 0.148 0.171 0.182 0.194 0.212 0.230 0.250 0.269 0.284 0.298 0.313 0.327

500 0.166 0.187 0.197 0.208 0.232 0.257 0.279 0.301 0.317 0.333 0.349 0.365

550 0.183 0.203 0.213 0.223 0.253 0.283 0.308 0.332 0.350 0.367 0.385 0.403

600 0.2 0.219 0.228 0.237 0.274 0.31 0.337 0.363 0.383 0.402 0.422 0.441

650 0.217 0.244 0.257 0.270 0.303 0.337 0.366 0.395 0.414 0.433 0.452 0.471

700 0.235 0.269 0.286 0.303 0.333 0.364 0.395 0.426 0.445 0.463 0.482 0.500

750 0.252 0.294 0.314 0.335 0.363 0.390 0.424 0.458 0.476 0.494 0.512 0.530

800 0.269 0.319 0.343 0.368 0.393 0.417 0.453 0.489 0.507 0.524 0.542 0.559

850 0.286 0.339 0.365 0.392 0.418 0.444 0.482 0.520 0.542 0.563 0.585 0.606

900 0.304 0.359 0.387 0.415 0.443 0.471 0.511 0.552 0.577 0.602 0.627 0.653

950 0.321 0.380 0.409 0.439 0.468 0.497 0.540 0.583 0.612 0.641 0.670 0.699

1000 0.338 0.4 0.431 0.462 0.493 0.524 0.569 0.614 0.647 0.68 0.713 0.746

430 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Pressure loss and sound power level
ΔP [Pa]
Calculation Correction factor Kp
formula
0° 22° 45°
ΔPp = ΔP x Kp
Kp 1 1.25 1.5

Calculation Correction factor K


formula
Sap [m2] 0.01 0.02 0.05 0.07 0.1 0.2
LWA = LWAO x K
K [dBA] –9 –6 –3 –1.5 0 +3

Designation:
ΔPp – pressure loss at various vane positions [Pa]
ΔP – pressure loss [Pa]
Kp – correction factor for pressure loss calculation depending on louvre deflection
V [m/s] angle
ΔP f(V) [Pa] LWA – sound power level [dBA]
Lwao [dBA]
LWAO – sound power level for air pass 0.1 m2 [dBA]
K – correction factor for sound power level calculation depending on air pass [dBA]
Sap – air pass [m2]
V – rated speed [m/s]

Order code

LxH

Grille type: Grille coating:


ORK – single-row sectional grille with individually adjustable "___ " – colour* (white by default)
louvres "Anodized"

Vane position: Accessories:


1 – parallel (deflection angle 0°) ___ – no
2 – pairwise perpendicular (deflection angle 15°) R – air flow regulator
A – adapter

Grille size: Grille fixation:


L – length [mm] u – versatile
H – height [mm]

* Standard polymer coating colours:

white beige brown grey blue black


RAL 9016 RAL 1015 RAL 8017 RAL 7001 RAL 5005 RAL 9005

Overall and mounting dimensions

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 431


SUPPLY AND EXHAUST GRILLES

Series Application
DR • Supply and exhaust ventilation, heating
and air conditioning networks in industrial,
commercial and domestic premises.

Design
• Made of high-quality extruded aluminium.

• Two louvre rows provide smooth air flow distribution.

• Smooth air direction adjustment (360°).

• Polymer or anodized grille coating


ensures weather-resistant properties.

• Non-standard sizes may be ordered.

Modifications
• Available modifications with an air flow regulator
(R) and an adapter (A) for connection to air ducts.

• Available modifications with versatile


fixing (u) for fast mounting.

Double-row ventilation grille


with adjustable louvres

Standard size [mm] and air pass [m2]

Length L [mm]
Height H [mm]
100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000

100 0.004 0.008 0.014 0.018 0.023 0.027 0.033 0.038 0.044 0.046 0.049 0.055 0.061 0.067 0.072 0.076 0.080 0.084 0.088

150 0.015 0.020 0.026 0.031 0.037 0.042 0.044 0.047 0.049 0.052 0.058 0.064 0.070 0.075 0.079 0.083 0.087 0.091

200 0.025 0.034 0.040 0.048 0.054 0.063 0.072 0.077 0.082 0.089 0.096 0.104 0.112 0.118 0.124 0.130 0.136

250 0.045 0.053 0.064 0.072 0.082 0.093 0.099 0.105 0.112 0.118 0.128 0.138 0.146 0.153 0.161 0.168

300 0.062 0.075 0.084 0.098 0.113 0.121 0.129 0.140 0.150 0.163 0.175 0.185 0.194 0.204 0.213

350 0.091 0.102 0.116 0.130 0.140 0.150 0.161 0.171 0.186 0.200 0.211 0.222 0.232 0.243

400 0.118 0.137 0.155 0.167 0.179 0.191 0.203 0.221 0.238 0.251 0.264 0.276 0.289

450 0.148 0.171 0.182 0.194 0.212 0.230 0.250 0.269 0.284 0.298 0.313 0.327

500 0.187 0.197 0.208 0.232 0.257 0.279 0.301 0.317 0.333 0.349 0.365

550 0.199 0.223 0.253 0.283 0.308 0.332 0.350 0.367 0.385 0.403

600 0.237 0.274 0.310 0.337 0.363 0.383 0.402 0.422 0.441

650 0.137 0.233 0.314 0.395 0.414 0.433 0.452 0.471

700 0.155 0.291 0.426 0.445 0.463 0.482 0.500

750 0.145 0.458 0.476 0.494 0.512 0.530

800 0.489 0.507 0.524 0.542 0.559

850 0.253 0.393 0.500 0.606

900 0.262 0.457 0.653

950 0.229 0.699

1000 0.746

432 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Pressure loss and sound power level
ΔP [Pa]
Calculation Correction factor Kp
formula
0° 22° 45°
ΔPp = ΔP x Kp
Kp 1 1.25 1.5

Calculation Correction factor K


formula
Sap [m2] 0.01 0.02 0.05 0.07 1 2
LWA = LWAO x K
K [dBA] –9 –6 –3 –1.5 0 +3

Designation:
ΔPp – pressure loss at various vane positions [Pa]
ΔP – pressure loss [Pa]
Kp – correction factor for pressure loss calculation depending on louvre deflection
V [m/s] angle
ΔP f(V) [Pa] LWA – sound power level [dBA]
Lwao [dBA]
LWAO – sound power level for air pass 0.1 m2 [dBA]
K – correction factor for sound power level calculation depending on air pass [dBA]
Sap – air pass [m2]
V – rated speed [m/s]

Order code

LxH

Grille type: Grille coating:


DR – double-row grille with individually adjustable louvres "___ " – colour* (white by default)
"Anodized"

Grille size: Accessories:


L – length [mm] ___ – no
H – height [mm] R – air flow regulator
A – adapter

Grille fixation:
u – versatile

* Standard polymer coating colours:

white beige brown grey blue black


RAL 9016 RAL 1015 RAL 8017 RAL 7001 RAL 5005 RAL 9005

Overall and mounting dimensions

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 433


CEILING DIFFUSERS

Series Application
DP • Supply and exhaust ventilation, heating
and air conditioning networks in industrial,
commercial and domestic premises.

Design
• Made of high-quality extruded aluminium.

• Four-sided uniform air flow distribution.

• Ideal solution for installation into the


Armstrong suspended ceilings.

• Polymer or anodized grille coating


ensures weather-resistant properties.

• Non-standard sizes may be ordered.

Modifications
• Available modifications with an air flow regulator
(R) and an adapter (A) for connection to air ducts.

Ceiling diffuser with fixed vanes

Standard size [mm] and air pass [m2]

Length L [mm]

L 258 326 394 462 530 600


H l 146 213 282 349 418 488
h
258 146 0.015 0.020 0.024 0.029 0.034 0.038
Height H [mm]

326 213 0.030 0.037 0.044 0.051 0.058

394 282 0.049 0.058 0.068 0.077

462 349 0.073 0.085 0.096

530 418 0.101 0.115

600 488 0.134

434 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Pressure loss and sound power level

ΔP [Pa]

- 258х258
- 326х326
- 394x394
- 462x462
5 - 530x530
6 - 600x600

Designation:
ΔP – pressure loss [Pa]
Q – air flow [m3/h]
LWA –sound power level [dBA]

Q [m3/s]
ΔP f(Q) [Pa]
Lwao [dBA]

Order code

LxH

Grille type: Grille coating:


DP – ceiling diffuser "___ " – colour* (white by default)
"Anodized"

Grille size: Accessories:


L – length [mm] ___ – no
H – height [mm] R – air flow regulator
A – adapter

* Standard polymer coating colours:

white beige brown grey blue black


RAL 9016 RAL 1015 RAL 8017 RAL 7001 RAL 5005 RAL 9005

Overall and mounting dimensions

L - 50 x H - 50

l+6xh+6

lxh

LxH

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 435


CEILING DIFFUSERS

Series Application
DPp • Supply and exhaust ventilation, heating
and air conditioning networks in industrial,
commercial and domestic premises.

Design
• Made of high-quality extruded aluminium.

• Four-sided uniform air flow distribution.

• Ideal solution for installation into the


Armstrong suspended ceilings.

• Polymer or anodized grille coating


ensures weather-resistant properties.

• Non-standard sizes may be ordered.

Modifications
• Available modifications with an air flow regulator
(R) and an adapter (A) for connection to air ducts.

Ceiling diffuser with fixed vanes

Standard size [mm] and air pass [m2]

A B Air pass [m2]

595 140 0.014

595 215 0.034

595 290 0.053

595 365 0.084

436 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Pressure loss and sound power level
∆P [Pa]

- 595х140
- 595х215
- 595x290
- 595x365

Designation:
ΔP – pressure loss [Pa]
Q – air flow [m3/h]
Q [m /h]
3

∆Pf (Q) [Pa] LWA –sound power level [dBA]


Lwao [dB(А)]

Order code

AxB

Grille type: Grille coating:


DPp – ceiling diffuser "___ " – colour* (white by default)
"Anodized"

Grille size: Accessories:


A – outer size [mm] ___ – no
V – cross section size [mm] R – air flow regulator
A – adapter

* Standard polymer coating colours:

white beige brown grey blue black


RAL 9016 RAL 1015 RAL 8017 RAL 7001 RAL 5005 RAL 9005

Overall and mounting dimensions

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 437


SLIT DIFFUSERS

Series Application
DS • Supply and exhaust ventilation, heating
and air conditioning networks in industrial,
commercial and domestic premises.

Design
• Made of high-quality extruded aluminium.

• Focused air flow distribution.

• Air flow direction control.

• Polymer or anodized grille coating


ensures weather-resistant properties.

• Non-standard sizes may be ordered.

Slit diffuser
Modifications
• Available modifications with an adapter
(A) for connection to air ducts.

• Available modifications with versatile fixing (u)


or with special springs (p) for fast mounting.

Standard size [mm] and air pass [m2]

Height H [mm] Length L [mm]

Number of
H, mm 200 300 400 500 600 700 800 900 1000 1200 1400 1500 1600 1800 2000
slits

1 62 0.0043 0.0067 0.009 0.0114 0.0138 0.0162 0.0186 0.0209 0.0233 0.0281 0.0328 0.0352 0.0376 0.0423 0.0471

2 106 0.0086 0.0134 0.0180 0.0228 0.0276 0.0324 0.0372 0.0418 0.0466 0.0562 0.0656 0.0704 0.0752 0.0846 0.0942

3 151 0.0129 0.0201 0.0270 0.0342 0.0414 0.0486 0.0558 0.0627 0.0699 0.0843 0.0984 0.1056 0.1128 0.1269 0.1413

4 195 0.0172 0.0268 0.0360 0.0456 0.0552 0.0648 0.0744 0.0836 0.0932 0.1124 0.1312 0.1408 0.1504 0.1692 0.1884

5 239 0.0215 0.0335 0.0450 0.0570 0.0690 0.0810 0.0930 0.1045 0.1165 0.1405 0.1640 0.1760 0.1880 0.2115 0.2355

6 283 0.0258 0.0402 0.0540 0.0684 0.0828 0.0972 0.1116 0.1254 0.1398 0.1686 0.1968 0.2112 0.2256 0.2538 0.2826

438 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Pressure loss and sound power level

∆P [Pa] Calculation Correction factor Kp


formula
0° 45°
ΔPp = ΔP x Kp
Kp 1 1.5

Calculation Correction factor K


formula
Sap [m2] 0.01 0.02 0.05 0.1 0.2 0.4
LWA = LWAO x K
K [dBA] –9 –6 –3 0 +3 +6

Designation:
ΔPp – pressure loss at various vane positions [Pa]
ΔP – pressure loss [Pa]
Kp – correction factor for pressure loss calculation depending on louvre deflection
angle
V [m/s] LWA – sound power level [dBA]
∆Pf (V) [Pа]
LWAO [dBA]
LWAO – sound power level for air pass 0.1 m2 [dBA]
K – correction factor for sound power level calculation depending on air pass [dBA]
Sap – air pass [m2]
V – rated speed [m/s]

Order code

xLxH
Grille coating:
"___ " – colour* (white by default)
"Anodized"
Grille type:
DS – slit diffuser

Accessories:
Number of slits:
___ – no
1, 2, 3, 4, 5, 6
A – adapter

Grille size: Grille fixation:


L – length [mm] u – versatile
H – height [mm] p – spring

* Standard polymer coating colours:

white beige brown grey blue black


RAL 9016 RAL 1015 RAL 8017 RAL 7001 RAL 5005 RAL 9005

Overall and mounting dimensions

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 439


PERFORATED GRILLES

Series Application
RP • Supply and exhaust ventilation, heating
and air conditioning networks in industrial,
commercial and domestic premises.

Design
• Made of high-quality extruded aluminium shape and
an insert piece of perforated steel or expanded mesh.

• Polymer or anodized grille coating


ensures weather-resistant properties.

• Non-standard sizes may be ordered.

Modifications
• Available modifications with an adapter
Exhaust ventilation grille with a mesh insert (A) for connection to air ducts.

• Available modifications with versatile fixing (u)


or with special springs (p) for fast mounting.

RP1 – expanded metal insert RP2 –perforated insert


with round holes

Standard size [mm] and air pass [m2]


Length L [mm]
Height H [mm]
100 150 200 250 300 350 400 450 500 600 700 800 900 1000
100 0.006 0.008 0.010 0.012 0.016 0.018 0.020 0.023 0.026 0.033 0.037 0.043 0.047 0.050
150 0.010 0.015 0.019 0.024 0.027 0.030 0.041 0.046 0.051 0.059 0.068 0.075 0.082
200 0.022 0.028 0.036 0.040 0.044 0.054 0.062 0.076 0.087 0.102 0.113 0.124
250 0.038 0.042 0.048 0.054 0.073 0.083 0.103 0.118 0.138 0.153 0.168
Expanded metal sheet

300 0.058 0.065 0.071 0.099 0.112 0.139 0.159 0.176 0.199 0.221
350 0.067 0.087 0.110 0.123 0.153 0.175 0.211 0.231 0.252
400 0.102 0.120 0.134 0.166 0.190 0.245 0.264 0.282
450 0.143 0.162 0.201 0.230 0.269 0.299 0.328
500 0.184 0.228 0.261 0.305 0.338 0.371
600 0.283 0.324 0.378 0.419 0.460
700 0.370 0.433 0.480 0.527
800 0.505 0.561 0.616
900 0.628 0.684
1000 0.751

Length L [mm]
Height H [mm]
100 150 200 250 300 350 400 450 500 600 700 800 900 1000
100 0.003 0.005 0.007 0.009 0.011 0.013 0.015 0.017 0.019 0.024 0.026 0.032 0.035 0.038
150 0.008 0.012 0.014 0.017 0.021 0.024 0.027 0.031 0.039 0.043 0.520 0.058 0.063
200 0.017 0.021 0.026 0.031 0.035 0.040 0.046 0.057 0.063 0.076 0.084 0.092
250 0.026 0.032 0.038 0.044 0.050 0.057 0.071 0.078 0.094 0.104 0.114
Perforated sheet

300 0.041 0.049 0.056 0.063 0.071 0.088 0.101 0.118 0.131 0.143
350 0.059 0.066 0.074 0.083 0.104 0.119 0.139 0.154 0.169
400 0.076 0.085 0.095 0.120 0.137 0.160 0.177 0.194
450 0.096 0.109 0.135 0.149 0.180 0.198 0.216
500 0.123 0.138 0.153 0.170 0.204 0.246
600 0.154 0.171 0.190 0.228 0.274
700 0.189 0.210 0.253 0.304
800 0.233 0.281 0.338
900 0.338 0.407
1000 0.489

440 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Pressure loss and sound power level
ΔP [Pa]
Calculation Correction factor K
formula
– expanded metal Sap [m2] 0.001 0.01 0.02 0.05 0.1 0.2 0.4
– perforated LWA=LWAO + K
K [dBA] – – – – 0 +3 +6

Designation:
ΔP – pressure loss [Pa]
LWA – sound power level [dBA]
LWAO – sound power level for air pass 0.1 m2 [dBA]
K – correction factor for sound power level calculation depending on air pass [dBA]
Sap – air pass [m2]
V – rated speed [m/s]

V [m/s]
ΔP f(V) [Pa]
Lwao [dBA]

Order code

LxH

Grille type: Grille coating:


RP – grille with a mesh insert "___ " – colour* (white by default)
"Anodized"

Filling insert type: Accessories:


1 – expanded metal ___ – no
2 – perforated with round holes A – adapter

Grille size: Grille fixation:


L – length [mm] u – versatile
H – height [mm] p – spring

* Standard polymer coating colours:

white beige brown grey blue black


RAL 9016 RAL 1015 RAL 8017 RAL 7001 RAL 5005 RAL 9005

Overall and mounting dimensions

LxH
L - 19 x H - 19
L - 22 x H - 22

L + 26 x H + 26

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 441


OUTER GRILLES

Series Application
RN • Supply and exhaust ventilation, heating
and air conditioning networks in industrial,
commercial and domestic premises.

Design
• Made of high-quality extruded aluminium shape and
an insert piece of perforated steel or expanded mesh.

• Reinforced frame design provides


100 % grille rigidity.

• Special vane design prevents water


ingress into a ventilation system.

• A built-in protecting mesh prevents ingress


of foreign objects into a ventilation system.

• Polymer or anodized grille coating


ensures weather-resistant properties.

• Non-standard sizes may be ordered.

Modifications
• Available modifications with an adapter
Supply and exhaust ventilation grille (A) for connection to air ducts.
with fixed vanes
• Available modifications with versatile
fixing (u) for fast mounting.

Air flow distributions

fixed (45°)

Standard size [mm] and air pass [m2]


Length L [mm]
Height H [mm]
300 350 400 450 500 600 700 800 900 1000

300 0.039 0.047 0.054 0.061 0.067 0.079 0.087 0.099 0.115 0.127

350 0.059 0.066 0.074 0.082 0.096 0.106 0.121 0.140 0.155

400 0.078 0.087 0.096 0.112 0.125 0.143 0.164 0.182

450 0.102 0.111 0.131 0.144 0.165 0.189 0.210

500 0.125 0.150 0.163 0.187 0.213 0.237

600 0.168 0.201 0.231 0.262 0.292

700 0.239 0.275 0.311 0.347

800 0.318 0.360 0.401

900 0.409 0.456

1000 0.511

442 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Pressure loss and sound power level
∆P [Pa]
Calculation Correction factor K
formula
Sap [m2] 0.03 0.05 0.07 0.10 0.15 0.2 0.3 0.4
LWA=LWAO + K
K [dBA] 4.5 3 1.5 0 +1.5 +3 +4.5 +6

Designation:
ΔP – pressure loss [Pa]
LWA – sound power level [dBA]
LWAO – sound power level for air pass 0.1 m2 [dBA]
– air supply K – correction factor for sound power level calculation depending on air pass [dBA]
– air exhaust Sap – air pass [m2]
V – rated speed [m/s]

V [m/s]
∆Pf (V) [Pа]
L WAO [dBA]

Order code

LxH

Grille type: Grille coating:


RN – outer grille "___ " – colour* (white by default)
"Anodized"

Grille size: Accessories:


L – length [mm] ___ – no
H – height [mm] A – adapter

Grille fixation:
u – versatile

* Standard polymer coating colours:

white beige brown grey blue black


RAL 9016 RAL 1015 RAL 8017 RAL 7001 RAL 5005 RAL 9005

Overall and mounting dimensions

LxH
L-8xH-8

L + 30 x H + 30

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 443


GRAVITY GRILLES

Series Application
RG • Exhaust ventilation, heating and
air conditioning networks in industrial,
commercial and domestic premises.

Design
• Made of high-quality extruded aluminium shape and
an insert piece of perforated steel or expanded mesh.

• Polymer or anodized grille coating


ensures weather-resistant properties.

• Non-standard sizes may be ordered.

Modifications
• Available modifications with an adapter
(A) for connection to air ducts.

• Available modifications with versatile


fixing (u) for fast mounting.

Ventilation grille with gravity shutters

Standard size [mm] and air pass [m2]

Length L [mm]
Height H [mm]
100 150 200 250 300 350 400 450 500

100 0.002 0.008 0.014 0.018 0.023 0.027 0.033 0.038 0.044

150 0.005 0.011 0.017 0.021 0.026 0.030 0.036 0.041 0.047

200 0.008 0.018 0.025 0.031 0.040 0.045 0.054 0.062 0.072

250 0.010 0.021 0.032 0.038 0.048 0.055 0.066 0.076 0.043

300 0.013 0.027 0.041 0.051 0.062 0.071 0.084 0.096 0.113

350 0.016 0.031 0.046 0.057 0.073 0.081 0.096 0.11 0.13

400 0.019 0.037 0.055 0.068 0.087 0.100 0.114 0.131 0.155

450 0.022 0.042 0.062 0.077 0.098 0.112 0.132 0.148 0.171

500 0.024 0.047 0.069 0.085 0.109 0.125 0.144 0.166 0.187

444 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Pressure loss and sound power level
∆P [Pa]
Calculation Correction factor Kp
formula
0° 22° 45°
ΔPp = ΔP x Kp
Kp 1 1.25 1.5

Calculation Correction factor K


formula
Sap [m2] 0.01 0.02 0.05 0.1 0.2 0.4
LWA = LWAO x K
K [dBA] –9 –6 –3 0 +3 +6

Designation:
ΔPp – pressure loss at various vane positions [Pa]
ΔP – pressure loss [Pa]
Kp – correction factor for pressure loss calculation depending on louvre deflection

V [m/s] angle
∆Pf (V) [Pа] LWA – sound power level [dBA]
L WAO [dBA]
LWAO – sound power level for air pass 0.1 m2 [dBA]
K – correction factor for sound power level calculation depending on air pass [dBA]
Sap – air pass [m2]
V – rated speed [m/s]

Order code

LxH

Grille type: Grille coating:


RG – gravity grille "___ " – colour* (white by default)
"Anodized"

Grille size: Accessories:


L – length [mm] ___ – no
H – height [mm] A – adapter

Grille fixation:
u – versatile

* Standard polymer coating colours:

white beige brown grey blue black


RAL 9016 RAL 1015 RAL 8017 RAL 7001 RAL 5005 RAL 9005

Overall and mounting dimensions

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 445


GRAVITY GRILLES

Series Application
RGS • Exhaust ventilation, heating and
air conditioning networks in industrial,
commercial and domestic premises.

Design
• Made of high-quality extruded aluminium shape and
an insert piece of perforated steel or expanded mesh.

• Polymer or anodized grille coating


ensures weather-resistant properties.

• Non-standard sizes may be ordered.

Modifications
• Available modifications with an adapter
(A) for connection to air ducts.

Sectional ventilation grille • Available modifications with versatile fixing (u)


or with special springs (p) for fast mounting.
with gravity shutters

Standard size [mm] and air pass [m2]

Height Length L [mm]


H [mm] 100 140 180 220 260 300 340 380 420 460 500 540 580 620 660 700 740 780 820 860 900 940 980

100 – – – – – – – – – – – 0.045 0.048 0.053 0.058 0.061 0.066 0.07 0.074 0.078 0.08 0.083 0.087

140 – – – – – – – – – – – 0.064 0.068 0.075 0.083 0.086 0.093 0.1 0.106 0.111 0.115 0.119 0.123

180 – – – – – – – – – – – 0.083 0.088 0.097 0.108 0.111 0.12 0.13 0.138 0.144 0.15 0.155 0.159

220 – – – – – – – – – – – 0.102 0.108 0.119 0.133 0.136 0.147 0.16 0.17 0.177 0.185 0.191 0.195

260 – – – – – – – – – – – 0.121 0.128 0.141 0.158 0.161 0.174 0.19 0.202 0.21 0.22 0.227 0.231

300 – – – – – – – – – – – 0.14 0.148 0.163 0.183 0.186 0.201 0.22 0.234 0.243 0.255 0.263 0.267

340 – – – – – – – – – – – 0.159 0.168 0.185 0.208 0.211 0.228 0.25 0.266 0.276 0.29 0.299 0.303

380 – – – – – – – – – – – 0.178 0.188 0.207 0.233 0.236 0.255 0.28 0.298 0.309 0.325 0.335 0.339

420 – – – – – – – – – – – 0.197 0.208 0.229 0.258 0.261 0.282 0.31 0.33 0.342 0.36 0.371 0.375

460 – – – – – – – – – – – 0.216 0.228 0.251 0.283 0.286 0.309 0.34 0.362 0.375 0.395 0.407 0.411

500 – – – – – – – – – – – 0.235 0.248 0.273 0.308 0.311 0.336 0.37 0.394 0.408 0.43 0.443 0.447

540 0.024 0.04 0.078 0.104 0.118 0.1 0.125 0.14 0.145 0.172 0.231 0.254 0.268 0.295 0.333 0.336 0.363 0.4 0.426 0.441 0.465 0.479 0.483

580 0.026 0.043 0.084 0.112 0.127 0.107 0.134 0.15 0.155 0.184 0.248 0.273 0.288 0.317 0.358 0.361 0.39 0.43 0.458 0.474 0.5 0.515 0.519

620 0.028 0.046 0.09 0.12 0.136 0.114 0.143 0.16 0.165 0.196 0.265 0.292 0.308 0.339 0.383 0.386 0.417 0.46 0.49 0.507 0.535 0.551 0.555

660 0.03 0.049 0.096 0.128 0.145 0.121 0.152 0.17 0.175 0.208 0.282 0.311 0.328 0.361 0.408 0.411 0.444 0.49 0.522 0.54 0.57 0.587 0.591

700 0.032 0.052 0.102 0.136 0.154 0.128 0.161 0.18 0.185 0.22 0.299 0.33 0.348 0.383 0.433 0.436 0.471 0.52 0.554 0.573 0.605 0.623 0.627

740 0.034 0.055 0.108 0.144 0.163 0.135 0.17 0.19 0.195 0.232 0.316 0.349 0.368 0.405 0.458 0.461 0.498 0.55 0.586 0.606 0.64 0.659 0.663

780 0.036 0.058 0.114 0.152 0.172 0.142 0.179 0.2 0.205 0.244 0.333 0.368 0.388 0.427 0.483 0.486 0.525 0.58 0.618 0.639 0.675 0.695 0.699

820 0.038 0.061 0.12 0.16 0.181 0.149 0.188 0.21 0.215 0.256 0.35 0.387 0.408 0.449 0.508 0.511 0.552 0.61 0.65 0.672 0.71 0.731 0.735

860 0.04 0.064 0.126 0.168 0.19 0.156 0.197 0.22 0.225 0.268 0.367 0.406 0.428 0.471 0.533 0.536 0.579 0.64 0.682 0.705 0.745 0.767 0.771

900 0.042 0.067 0.132 0.176 0.199 0.163 0.206 0.23 0.235 0.28 0.384 0.425 0.448 0.493 0.558 0.561 0.606 0.67 0.714 0.738 0.78 0.803 0.807

940 0.044 0.07 0.138 0.184 0.208 0.17 0.215 0.24 0.245 0.292 0.401 0.444 0.468 0.515 0.583 0.586 0.633 0.7 0.746 0.771 0.815 0.839 0.843

980 0.046 0.073 0.144 0.192 0.217 0.177 0.224 0.25 0.255 0.304 0.418 0.463 0.488 0.537 0.608 0.611 0.66 0.73 0.778 0.804 0.85 0.875 0.879

446 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Pressure loss and sound power level
P (Pa)
Calculation Correction factor Kp
formula
0° 22° 45°
ΔPp = ΔP x Kp
Kp 1 1.25 1.5

Calculation Correction factor K


formula
Sap [m2] 0.01 0.02 0.05 0.1 0.2 0.4
LWA = LWAO x K
K [dBA] –9 –6 –3 0 +3 +6

Designation:
ΔPp – pressure loss at various vane positions [Pa]
ΔP – pressure loss [Pa]
Kp – correction factor for pressure loss calculation depending on louvre deflection
V, [m/s] angle
Pf [V], Pa
LWA – sound power level [dBA]
LWAO, dBA
LWAO – sound power level for air pass 0.1 m2 [dBA]
K – correction factor for sound power level calculation depending on air pass [dBA]
Sap – air pass [m2]
V – rated speed [m/s]

Order code

LxH

Grille type: Grille coating:


RGS – gravity grille "___ " – colour* (white by default)
"Anodized"

Grille size: Accessories:


L – length [mm] ___ – no
H – height [mm] A – adapter

Grille fixation:
u – versatile
p – spring

* Standard polymer coating colours:

white beige brown grey blue black


RAL 9016 RAL 1015 RAL 8017 RAL 7001 RAL 5005 RAL 9005

Overall and mounting dimensions

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 447


GRAVITY GRILLES

Series Application
GRM • Exhaust ventilation, heating and
air conditioning networks in industrial,
commercial and domestic premises.

Design
• Made of high-quality metal
shape with polymer coating

• Polymer or anodized grille coating


ensures weather-resistant properties.

• Shutters are made of PVC plactic.

• Non-standard sizes may be ordered.

Modifications
• Available modifications with an adapter
(A) for connection to air ducts.

• Available modifications with versatile fixing (u)


or with special springs (p) for fast mounting.

Ventilation grille with gravity shutters

Standard size [mm]

Model Inner cross section size L L1 L2 e

GRM 200 116x116 200 150 136 –

GRM 250 166x166 250 200 186 –

GRM 285 200x200 284 234 220 –

GRM 300 216x216 300 250 236 –

GRM 335 250x250 334 284 270 –

GRM 350 266x266 350 300 286 –

GRM 385 300x300 384 334 320 –

GRM 400 316x316 400 350 336 –

GRM 435 350x350 434 384 370 –

GRM 450 366x366 450 400 386 –

GRM 485 400x400 484 434 420 –

GRM 535 450x450 534 484 470 –

GRM 550 466x466 550 500 486 –

GRM 585 500x500 584 534 520 257.0

GRM 635 550x550 634 584 570 282.0

GRM 655 571x571 655 605 591 292.5

GRM 685 601x601 685 635 621 307.5

GRM 715 630x630 714 664 650 322.0

GRM 725 641x641 725 675 661 327.5

GRM 805 721x721 805 755 741 367.5

GRM 835 751x751 835 785 771 382.5

448 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Pressure loss and sound power level
∆P (Pa)
Calculation Correction factor Kp
formula
0° 22° 45°
ΔPp = ΔP x Kp
Kp 1 1.25 1.5

Calculation Correction factor K


formula
Sap [m2] 0.01 0.02 0.05 0.1 0.2 0.4
LWA = LWAO x K
K [dBA] –9 –6 –3 0 +3 +6

Designation:
ΔPp – pressure loss at various vane positions [Pa]
ΔP – pressure loss [Pa]
Kp – correction factor for pressure loss calculation depending on louvre deflection
angle
V [m/s]
∆Pf (V) [Pа] LWA – sound power level [dBA]
LWAO [dB(А)]
LWAO – sound power level for air pass 0.1 m2 [dBA]
K – correction factor for sound power level calculation depending on air pass [dBA]
Sap – air pass [m2]
V – rated speed [m/s]

Order code
L

Grille type: Grille coating:


GRM – gravity grille "___ " – colour* (white by default)

Grille size: Accessories:


L – outer size [mm] ___ – no
A – adapter

Grille fixation:
u – versatile
p – springs

* Standard polymer coating colours:

white beige brown grey blue black


RAL 9016 RAL 1015 RAL 8017 RAL 7001 RAL 5005 RAL 9005

Overall and mounting dimensions


L L
25 L1 L1
Ø 4,8
4 hole

L2 e e
L2

GRM 200 – GRM 550 GRM 585 – GRM 835

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 449


SWIRL DIFFUSERS

Series Application
DVK • Supply and exhaust ventilation, heating
and air conditioning networks in industrial,
commercial and domestic premises.

Design
• The base made of high-quality polymer
coated steel, the plastic inserts.

• Non-standard sizes may be ordered.

Modifications
• Suspended ceiling mounting.

• Air flow direction adjustment.

Swirl diffusers

Overall and mounting dimensions [mm]


Type A B C Air pass [m2]

DVK 295 295 295 25 0.015

DVK 305 305 305 25 0.015

DVK 395 395 395 25 0.030

DVK 445 445 445 25 0.030

DVK 495 495 495 25 0.050

DVK 595 595 595 25 0.075

DVK 620 620 620 25 0.075

DVK 695 695 695 25 0.075

DVK 795 795 795 25 0.075

DVK1 DVK3

DVK2

DVK4

450 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Series Application
DVP • Supply and exhaust ventilation, heating
and air conditioning networks in industrial,
commercial and domestic premises.

Design
• The base made of high-quality polymer
coated steel, the plastic inserts.

• Non-standard sizes may be ordered.

Modifications
• Suspended ceiling mounting.

• Air flow direction adjustment

Swirl diffusers

Overall and mounting dimensions [mm]


Type A B C Air pass [m2] Number of inserts

DVP 295 295 295 25 0.010 8

DVP 305 305 305 25 0.010 8

DVP 395 395 395 25 0.018 15

DVP 445 445 445 25 0.026 21

DVP 495 495 495 25 0.029 24

DVP 595 595 595 25 0.044 36

DVP 620 620 620 25 0.044 36

DVP 695 695 695 25 0.046 38

DVP 795 795 795 25 0.073 60

DVP2 DVP3

DVP1

DVP4

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 451


ADDITIONAL ACCESSORIES

Adapter Application
A DP • For connection of the square ceiling
diffusers DP to round air ducts.

Design
• Made of galvanized steel.

• Equipped with a sealing ring for


tight connection to air ducts.

• Two modifications: vertical and


horizontal connection to the air duct.

Overall and mounting dimensions of the adapter for ceiling diffusers


Order code (grille size, mm) l [mm] h [mm] ØD [mm] K [mm] Weight [kg] Order code (grille size, mm) l [mm] h [mm] ØD [mm] K [mm] Weight [kg]
Ab DP 225x225/100 113.6 113.6 100 178.6 0.62 Ab DP 460x460/250 348.6 348.6 250 413.6 3.5
Av DP 225x225/100 113.6 113.6 100 205.2 0.62 Av DP 460x460/250 348.6 348.6 250 355.2 3.5
Ab DP 260x260/100 148.6 148.6 100 213.6 0.83 Ab DP 530x260/125 418.6 148.6 125 213.6 1.62
Av DP 260x260/100 148.6 148.6 100 205.2 0.83 Av DP 530x260/125 418.6 148.6 125 205.2 1.62
Ab DP 260x260/125 148.6 148.6 125 213.6 0.92 Ab DP 530x325/150 418.6 213.6 150 278.6 2.5
Av DP 260x260/125 148.6 148.6 125 230.2 0.92 Av DP 530x325/150 418.6 213.6 150 276.2 2.5
Ab DP 300x300/150 188.6 188.6 150 253.6 1.3 Ab DP 530x394/250 418.6 282.6 250 347.6 3.4
Av DP 300x300/150 188.6 188.6 150 255.2 1.3 Av DP 530x394/250 418.6 282.6 250 346.2 3.4
Ab DP 325x325/100 213.6 213.6 100 278.6 1.2 Ab DP 530x460/315 418.6 348.6 315 413.6 4.4
Av DP 325x325/100 213.6 213.6 100 205.2 1.2 Av DP 530x460/315 418.6 348.6 315 416.2 4.4
Ab DP 325x325/160 213.6 213.6 160 278.6 1.56 Ab DP 596x596/160 484.6 484.6 160 549.6 4.2
Av DP 325x325/160 213.6 213.6 160 265.2 1.56 Av DP 596x596/160 484.6 484.6 160 265.2 4.2
Ab DP 394x260/125 282.6 148.6 125 213.6 1.22 Ab DP 596x596/315 484.6 484.6 315 549.6 5.98
Av DP 394x260/125 282.6 148.6 125 205.2 1.22 Av DP 596x596/315 484.6 484.6 315 420.2 5.98
Ab DP 394x325/150 282.6 213.6 150 278.6 1.9 Ab DP 596x260/125 488.6 148.6 125 213.6 1.82
ØD
Av DP 394x325/150 282.6 213.6 150 276.2 1.9 Av DP 596x260/125 488.6 148.6 125 205.2 1.82
Ab DP 394x394/100 282.6 282.6 100 347.6 1.74 Ab DP 596x325/150 488.6 213.6 150 278.6 2.79
Av DP 394x394/100 282.6 282.6 100 205.2 1.74 Av DP 596x325/150 488.6 213.6 150 276.2 2.79
Ab DP 394x394/200 282.6 282.6 200 347.6 2.4 Ab DP 596x394/250 488.6 282.6 250 347.6 3.8
Av DP 394x394/200 282.6 282.6 200 305.2 2.4 Av DP 596x394/250 488.6 282.6 250 346.2 3.8
Ab DP 460x260/125 348.6 148.6 125 213.6 1.41 Ab DP 596x460/315 488.6 348.6 315 413.6 4.9
Av DP 460x260/125 348.6 148.6 125 205.2 1.41 Av DP 596x460/315 488.6 348.6 315 416.2 4.9
Ab DP 460x325/150 348.6 213.6 150 278.6 2.2 Ab DP 596x530/315 488.6 418.6 315 483.6 5.45
I
Av DP 460x325/150 348.6 213.6 150 276.2 2.2 Av DP 596x530/315 488.6 418.6 315 416.2 5.45
Ab DP 460x394/250 348.6 282.6 250 347.6 3.02 Ab DP 620x620/250 508.6 508.6 250 573.6 6.75
Av DP 460x394/250 348.6 282.6 250 346.2 3.02 Av DP 620x620/250 508.6 508.6 250 455.2 6.75
Ab DP 460x460/100 348.6 348.6 100 413.6 2.28 Ab DP 695x695/315 583.6 583.6 315 648.6 8.04
K
Av DP 460x460/100 348.6 348.6 100 205.2 2.28 Av DP 695x695/315 583.6 583.6 315 455.2 8.04
Ab DP 460x460/200 348.6 348.6 200 413.6 3.12 Ab DP 795x795/315 683.6 683.6 315 748.6 9.88
Av DP 460x460/200 348.6 348.6 200 305.2 3.12 Av DP 795x795/315 683.6 683.6 315 455.2 9.88

ØD

I
I

Horizontal adapter Vertical adapter

452 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Order generation system

Model Spigot diameter [mm]


A Nominal diameter of the spigot for
connection to the air duct

Connection to a duct
L x H: nominal size of the DP diffuser
b: horizontal connection
v: vertical connection

DP: type of diffusers


for which the adapter is designed for

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 453


ADDITIONAL ACCESSORIES

Adapter A DR/ORK Application

• For connection of the ORK and DR grilles to round air


ducts.

Design
• Made of galvanised steel.
• Equipped with a sealing ring for tight connection to
air ducts.
• One modification: vertical connection to the air duct.

Overall and mounting dimensions of the adapter for ceiling diffusers:


Code (grille size, mm) a [mm] b [mm] ØD [mm] Weight [kg] Code (grille size, mm) a [mm] b [mm] ØD [mm] Weight [kg]
Av ORV 100x100/80 120.2 123.2 81 0.2 Av ORV 500x250/150 270.2 523.2 201 0.96
Av ORV 150x100/80 120.2 183.2 81 0.25 Av ORV 550x250/150 270.2 583.2 201 1.03
Av ORV 200x100/80 120.2 223.2 81 0.29 Av ORV 600x250/150 270.2 623.2 201 1.1
Av ORV 250x100/80 120.2 283.2 81 0.33 Av ORV 300x300/200 320.2 323.2 201 0.75
Av ORV 300x100/80 120.2 323.2 81 0.37 Av ORV 350x300/200 320.2 383.2 201 0.83
Av ORV 350x100/80 120.2 383.2 81 0.42 Av ORV 400x300/200 320.2 423.2 201 0.91
Av ORV 400x100/80 120.2 423.2 81 0.46 Av ORV 450x300/200 320.2 483.2 201 0.99
Av ORV 450x100/80 120.2 483.2 81 0.5 Av ORV 500x300/200 320.2 523 201 1.08
Av ORV 500x100/80 120.2 523.2 81 0.55 Av ORV 550x300/200 320.2 573 201 1.16
Av ORV 550x100/80 120.2 583.2 81 0.59 Av ORV 600x300/200 320.2 623 201 1.24
Av ORV 600x100/80 120.2 623.2 81 0.63 Av ORV 350x350/315 370.6 373 316 0.87
Av ORV 150x150/125 170.2 183.2 126 0.32 Av ORV 400x350/315 370.6 423 316 0.97
Av ORV 200x150/125 170.2 223.2 126 0.37 Av ORV 450x350/315 370.6 473 316 1.06
Av ORV 250x150/125 170.2 283.2 126 0.43 Av ORV 500x350/315 370.6 523 316 1.15
Av ORV 300x150/125 170.2 323.2 126 0.48 Av ORV 550x350/315 370.6 573 316 1.25
Av ORV 350x150/125 170.2 383.2 126 0.53 Av ORV 600x350/315 370.6 623 316 1.34
Av ORV 400x150/125 170.2 423.2 126 0.59 Av ORV 400x400/350 420.6 423 350 0.97
Av ORV 450x150/125 170.2 483.2 126 0.64 Av ORV 450x400/350 420.6 473 350 1.07
Av ORV 500x150/125 170.2 523.2 126 0.69 Av ORV 500x400/350 420.6 523 350 1.18
Av ORV 550x150/125 170.2 583.2 126 0.75 Av ORV 550x400/350 420.6 573 350 1.28
Av ORV 600x150/125 170.2 623.2 126 0.8 Av ORV 600x400/350 420.6 623 350 1.38
Av ORV 200x200/150 220.2 223.2 151 0.45 Av ORV 450x450/400 470.6 473 400 1.29
Av ORV 250x200/150 220.2 283.2 151 0.51 Av ORV 500x450/400 470.6 523 400 1.4
Av ORV 300x200/150 220.2 323.2 151 0.58 Av ORV 550x450/400 470.6 573 400 1.51
Av ORV 350x200/150 220.2 283.2 151 0.64 Av ORV 600x450/400 470.6 623 400 1.62
Av ORV 400x200/150 220.2 423.2 151 0.7 Av ORV 500x500/400 520.6 523 400 1.52
Av ORV 450x200/150 220.2 483.2 151 0.77 Av ORV 550x500/400 520.6 573 400 1.64
Av ORV 500x200/150 220.2 523.2 151 0.83 Av ORV 600x500/400 520.6 623 400 1.77
Av ORV 550x200/150 220.2 583.2 151 0.89 Av ORV 200x140/100 320.6 423 101 0.89
Av ORV 600x200/150 220.2 623.2 151 0.95 Av ORV 240x140/100 220.6 232 101 0.56
Av ORV 250x250/150 270.2 283.2 201 0.6 Av ORV 400x300/100 220.6 423 101 0.68
Av ORV 300x250/150 270.2 323.2 201 0.66 Av ORV 300x200/100 170.6 273 101 0.42
Av ORV 350x250/150 270.2 383.2 201 0.74 Av ORV 400x200/100 470.6 473 400 1.29
Av ORV 400x250/150 270.2 423.2 201 0.81 Av ORV 250x150/100 420.6 523 400 1.4
Av ORV 450x250/150 270.2 483.2 201 0.88

ØD

454 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Adapter designation guide

Adapter name Dimensions [mm]


Ad: adapter Nominal spigot diameter for connection
to an air duct

Mating part
Package size
A: disk valve
Default – header bag
V: domestic fan
Thermal package – (t/p)
Sealed bag – (s/b)
Unsealed bag – (ns/b)

Designation example

Short name Full name Description


Adapter for a disk valve 100 mm in diameter,
Ad A 100 Ad A 100 adapter
packing – header bag
Adapter for a domestic fan 150 mm in diameter,
Ad V 150 (s/b) Ad V 150 (s/b) adapter
packing – sealed bag

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 455


ADDITIONAL ACCESSORIES

Adapter Application
A DVK/DVP • For connection of the square ceiling
diffusers DVP and DVK to round air ducts.

Design
• Made of galvanized steel.

• Equipped with a sealing ring for


tight connection to air ducts.

• Two modifications: vertical and


horizontal connection to an air duct.

Overall dimensions and mounting dimensions of the adapter for ceiling diffusers

Order code (grille size, mm) a [mm] b [mm] ØD [mm] K [mm] Weight [kg]
Ab DVP/DVK 295x295/125 292.6 292.6 125 347 1.42
Av DVP/DVK 295 x295/125 292.6 292.6 125 305.5 1.88
Ab DVP/DVK 295x295/140 292.6 292.6 140 347 1.44
Av DVP/DVK 295 x295/140 292.6 292.6 140 305.5 1.88
Ab DVP/DVK 305x305/125 302.6 302.6 125 357 1.49
Av DVP/DVK 305x305/125 302.6 302.6 125 305.5 1.96
Ab DVP/DVK 305x305/140 302.6 302.6 140 357 1.51
Av DVP/DVK 305x305/140 302.6 302.6 140 305.5 1.96
Ab DVP/DVK 395x395/160 392.6 392.6 160 447 2.46
Av DVP/DVK 395x395/160 392.6 392.6 160 305.5 2.69
Ab DVP/DVK 395x395/200 392.6 392.6 200 447 2.52
Av DVP/DVK 395x395/200 392.6 392.6 200 305.5 2.69
Ab DVP/DVK 445x445/160 442.6 442.6 160 497 2.9 a
Av DVP/DVK 445x445/160 442.6 442.6 160 305.5 3.1
Ab DVP/DVK 445x445/200 442.6 442.6 200 497 2.9
Av DVP/DVK 445x445/200 442.6 442.6 200 305.5 3.1
Ab DVP/DVK 495x495/200 492.6 492.6 200 547 3.94
Av DVP/DVK 495x495/200 492.6 492.6 200 305.5 3.59
Ab DVP/DVK 495x495/250 492.6 492.6 250 547 4
Av DVP/DVK 495x495/250 492.6 492.6 250 305.5 3.55
Ab DVP/DVK 595x595/250 592.6 592.6 250 647 5.44
Ab DVP/DVK 595x595/200 592.6 592.6 200 647 5.51
Av DVP/DVK 595x595/250 592.6 592.6 250 305.5 4.55
Ab DVP/DVK 595x595/315 592.6 592.6 315 647 5.55
Av DVP/DVK 595x595/315 592.6 592.6 315 305.5 4.47
Ab DVP/DVK 620x620/250 617.6 617.6 250 672 5.77
Av DVP/DVK 620x620/250 617.6 617.6 250 305.5 4.81 a
Ab DVP/DVK 620x620/315 617.6 617.6 315 672 5.89
Av DVP/DVK 620x620/315 617.6 617.6 315 305.5 4.73
Ab DVP/DVK 695x695/250 692.6 692.6 250 747 6.54
Av DVP/DVK 695x695/250 692.6 692.6 250 305.5 5.64 a
Ab DVP/DVK 695x695/315 692.6 692.6 315 747 6.63
Av DVP/DVK 695x695/315 692.6 692.6 315 305.5 5.56
Ab DVP/DVK 795x795/250 792.6 792.6 250 847 7.98
Av DVP/DVK 795x795/250 792.6 792.6 250 305.5 6.83
Ab DVP/DVK 795x795/315 792.6 792.6 315 847 8.13
Av DVP/DVK 795x795/315 792.6 792.6 315 305.5 6.75

456 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Order generation system

Model Spigot diameter [mm]


A Nominal diameter of the spigot for
connection to an air duct

Connection to a duct
Characteristic dimension (1 figure for round and 2
b – horizontal connection
figures for rectangular and square) [mm]
v – vertical connection
100x100 – adapter is designed for specified type of grilles
with characteristic dimension of 100x100 mm
Type of the connected unit 150 – adapter is designed for specified grille or diffuser
The adapter can be used for the following type with characteristic diameter of 150 mm
unit types:
DVP
DVK

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 457


ADDITIONAL ACCESSORIES

Adapter Application
• For connection of the DP, ORH, ORV, ONH, ONV,
ORK, ONL, ONS ventilation grilles with round air ducts.

Design
• Made of galvanized steel.

• Equipped with a sealing ring for


tight connection to air ducts.

Overall and mounting dimensions [mm]

Order code (grille size [mm]) L [mm] H [mm] ØD [mm] K [mm] Weight [kg]
A (100x100) 86.4 96.4 0.053
A (100x150) 86.4 146.4 0.081
A (100x200) 86.4 196.4 0.108
A (100x250) 86.4 246.4 0.136
A (100x300) 86.4 296.4 80 0.164
A (100x350) 86.4 346.4 0.191
A (100x400) 86.4 396.4 0.219
A (100x450) 86.4 446.4 0.246
A (100x500) 86.4 496.4 0.274
A (150x150) 136.4 146.4 0.128
A (150x200) 136.4 196.4 0.171
A (150x250) 136.4 246.4 0.215
A (150x300) 136.4 296.4 0.258
A (150x350) 136.4 346.4 125 0.302
A (150x400) 136.4 396.4 0.345
A (150x450) 136.4 446.4 0.389
A (150x500) 136.4 496.4 0.432
A (150x600) 136.4 596.4 0.519
A (200x200) 186.4 196.4 0.234
100
A (200x250) 186.4 246.4 0.293
A (200x300) 186.4 296.4 0.353
A (200x350) 186.4 346.4 0.412
150
A (200x400) 186.4 396.4 0.472
A (200x450) 186.4 446.4 0.531
A (200x500) 186.4 496.4 0.591
A (200x600) 186.4 596.4 0.710
A (250x250) 236.4 246.4 0.372
A (250x300) 236.4 296.4 0.447 H ØD
A (250x350) 236.4 346.4 0.523
A (250x400) 236.4 396.4 0.598
A (250x450) 236.4 446.4 0.674
A (250x500) 236.4 496.4 0.749
200
A (300x300) 236.4 296.4 0.542
A (300x350) 236.4 346.4 0.634
A (300x400) 236.4 396.4 0.725
L
A (300x450) 236.4 446.4 0.816 K
A (300x500) 236.4 496.4 0.908
A (300x600) 236.4 596.4 1.091
A (350x350) 336.4 346.4 0.744
A (350x400) 336.4 396.4 0.852
315
A (350x450) 336.4 446.4 0.959
A (350x500) 336.4 496.4 1.066
A (400x400) 386.4 396.4 0.978
150
A (400x450) 386.4 446.4 350 1.102
A (400x500) 386.4 496.4 1.225
A (450x450) 436.4 446.4 1.244
A (450x500) 436.4 496.4 400 1.383
A (500x500) 486.4 496.4 1.542

458 VENTS. Domestic ventilation. Catalogue №6 | 02-2020


Air flow regulator Application
• Multi-vane air flow regulator with counter-rotated
vanes is designed for air flow regulation of the DR,
ORH, ORV, ONV, ORK, ONL, ONS ventilation grilles.

Design
• Made of galvanized steel. The aluminium
rotating vanes are turned due to plastic gears.

• Equipped with a limit position stopper


regulated by a butterfly bolt.

Overall and mounting dimensions [mm]


Order code (grille size [mm]) L [mm] H [mm] L1 [mm] H1 [mm] Weight [kg]
R (100x100) 79 86 0.125
R (100x150) 129 136 0.168
R (100x200) 179 186 0.21
R (100x250) 229 236 0.253
R (100x300) 279 79 286 81.8 0.295
R (100x350) 329 336 0.343
R (100x400) 379 386 0.38
R (100x450) 429 436 0.425
R (100x500) 479 486 0.465
R (150x150) 129 136 0.235
R (150x200) 176 186 0.295
R (150x250) 226 236 0.355
R (150x300) 279 286 0.415
R (150x350) 329 129 336 131.8 0.475
R (150x400) 379 386 0.535
R (150x450) 429 436 0.295
R (150x500) 476 486 0.655
R (150x600) 579 586 0.775
R (200x200) 179 186 0.406
R (200x250) 229 236 0.477
R (200x300) 279 286 0.548 L1
R (200x350) 329 336 0.619
179 181.8
R (200x400) 379 386 0.69
R (200x450) 429 436 0.761 H
R (200x500) 476 486 0.832
R (200x600) 579 586 1.0
R (250x250) 229 236 0.63 H1
R (250x300) 279 286 0.7
R (250x350) 329 336 0.77
229 231.8
R (250x400) 379 386 0.84 L
R (250x450) 429 436 0.91
R (250x500) 479 486 0.98
R (300x300) 279 286 0.75
R (300x350) 329 336 0.855
R (300x400) 379 386 0.96
279 281.8
R (300x450) 429 436 1.065
R (300x500) 479 486 1.175
R (300x600) 579 586 1.39
R (350x350) 329 336 0.9
R (350x400) 379 386 1.13
319 321.8
R (350x450) 429 436 1.36
R (350x500) 479 486 1.59
R (400x400) 379 386 1.2
R (400x450) 429 379 436 381.8 1.43
R (400x500) 479 486 1.66
R (450x450) 429 436 1.52
429 431.8
R (450x500) 479 486 1.77
R (500x500) 479 479 486 481.8 2

VENTS. Domestic ventilation. Catalogue №6 | 02-2020 459


GRILLE FIXATION

Standard fixing

Fixing with a mounting pair (not included into the delivery set)

Features:
• mounting pair: versatile screw 3.5x35 mm; nylon dowel 6x40 mm;
• used for grille fixation into concrete or brick walls;
• the screw head has the grille colour;
• cross-shaped slot.

Versatile fixing

Fixing with a versatile lock fixed on the grille

Features:
• versatile lock enables mounting into walls and ceilings
• easy mounting with a screw-driver
• concealed fixing.

Spring fixation

Features:
• mounting into walls (no ceiling mounting);
• concealed fixing.

The mounting kit delivery set includes:


• flange for fixation of the grille into the wall
opening;
• set of springs.

460 VENTS. Domestic ventilation. Catalogue №6 | 02-2020

You might also like