596.1305 en 201705 Airtelligence Provis 2.0 Visu

This document provides operating instructions for the airtelligence provis 2.0 visualization software. It describes the basic functions available in the light version, including viewing status, profiles, historical analysis and events. It then explains how to activate the full version, which provides additional features such as reporting, alarms, user management and segment creation. The full version dashboard is explained in detail, outlining the data selection, overview tables, and custom report generation capabilities.

Uploaded by

Piotr
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
253 views20 pages

596.1305 en 201705 Airtelligence Provis 2.0 Visu

This document provides operating instructions for the airtelligence provis 2.0 visualization software. It describes the basic functions available in the light version, including viewing status, profiles, historical analysis and events. It then explains how to activate the full version, which provides additional features such as reporting, alarms, user management and segment creation. The full version dashboard is explained in detail, outlining the data selection, overview tables, and custom report generation capabilities.

Uploaded by

Piotr
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 20

 

Operating
instructions

Visualisation
airtelligence provis 2.0
Operating instructions
Visualisation
airtelligence provis 2.0
- Software version V2.0.1 -

BOGE KOMPRESSOREN
Otto Boge GmbH & Co. KG
Postfach 10 07 13
33507 Bielefeld, Germany

Otto-Boge-Strasse 1-7
33739 Bielefeld, Germany

Tel: +49 5206 601-0


Fax: +49 5206 601-200
Mail: [email protected]
Web: www.boge.com

Date: 05 / 2017
No. 596.1305.01
Nominal charge: € 5.00

BOGE Operating instructions Visualisation airtelligence provis 2.0


 
Table of contents 
 

1.  General information .......................................................................................................1 


2.  Quick introduction to the light version ..........................................................................1 
2.1.  Status and Profiles ..........................................................................................................2 
2.2.  History – Analysis............................................................................................................2 
2.3.  History – Events ..............................................................................................................4 
2.4.  Settings – General...........................................................................................................5 
3.  Activate the full version..................................................................................................5 
4.  The functions of the full version.....................................................................................6 
4.1.  History – Reporting.........................................................................................................6 
4.2.  Facility Alarms.................................................................................................................8 
4.3.  Settings – Notifications.................................................................................................10 
4.4.  Settings – User Management .......................................................................................10 
4.5.  Create new segment.....................................................................................................12 
 

BOGE Operating instructions Visualisation airtelligence provis 2.0 Page 1


Page 2 BOGE Operating instructions Visualisation airtelligence provis 2.0
1. General information 

The airtelligence provis 2.0 visualisation is a browser‐based application that is installed on a 
virtual operating system (also referred to as a virtual machine).  

This gives you the advantage of being able to use the software after completing just a few 
configuration steps. Before the visualisation application can run, the airtelligence provis 2.0 
control system must be fully installed, since this makes the necessary runtime data available.  

The sections that follow describe the various steps to be carried out before using the visualization 
for the first time. Read through the following recommendations before you start to ensure your 
PC meets the necessary system requirements. 

System requirements: 
 Multi‐core processor, 
 4GB RAM, 
In this respect, it depends whether the computer is only required for visualization purposes, or whether 
other applications should be performed as well. To ensure that the system works smoothly, the virtual 
machine (VM) should have at least 4 GB (RAM) available, 
 At least 21GB free hard drive space. 

2. Quick introduction to the light version 

1. Start up your web browser. 

2. Enter the URL http://“IP address of the virtual machine”:8080.  

The visualisation starts by showing the status screen: 

BOGE Operating instructions Visualisation airtelligence provis 2.0 Page 1


The light version includes the following: 

 Status (Facility, Compressor, Compressor Detail, Accessories) 
 Profiles  
 History (Analysis, Events) 
 Settings (General) 

2.1. Status and Profiles 
The Status and Profiles screens are similar to the display on the control unit and are therefore not 
explained in detail here. In contrast to the control unit, however, the settings can only be read out 
here and cannot be altered. 

2.2. History – Analysis  
The History screen has two subdivisions: “Analysis” and “Events”. The “Analysis” category allows 
the evaluation of the facility’s behaviour to be shown graphically.  

Here, you can select an analysis timespan and see the runtime data for the selected section in the 
form of a graph. The values to be shown in the history diagram can be defined in the middle 
section of the screen. Four of five status parameters can be allocated to a particular X axis.  

Page 2 BOGE Operating instructions Visualisation airtelligence provis 2.0


The facility status and the currently active profile are always visible. 

Profile 

Facility status 

The key for the facility status appears as a tool tip when you hold the mouse pointer over it. The 
colours have the same significance as those in the control unit. 

In addition, you can click on the   symbol to show history graphs for pressure, flow rate, facility 
load, power and efficiency:  

 
 

BOGE Operating instructions Visualisation airtelligence provis 2.0 Page 3


2.3. History – Events  

This screen shows the saved events from the control unit. You can alter the period of 
consideration in order to give a better overview. It is also possible to sort the list according to type 
of error (first column), error code, module, date and time or status. Tool tips give details of each 
entry (when you hold the mouse pointer over them); this is also similar to the display on the 
control unit. 

The “Export PDF” and “Export CSV” buttons offer two options for exporting the displayed list and 
saving it as either a PDF or CSV file. 

Page 4 BOGE Operating instructions Visualisation airtelligence provis 2.0


2.4. Settings – General  
The settings screen allows you to adjust the general settings, such as language and units of 
measurement: 

3. Activate the full version 
1. Click on the link at the top right of the screen (below the date and time indicator).  

2. Copy the activation code to the clipboard (by selecting it and then pressing CTRL + C).  

3. Click on the link for online activation. 

Copy 

4. Paste the activation code into the corresponding field (CTRL + V). 

5. Fill in the other fields with the relevant data.  

6. Send the activation request by confirming the entries. 

BOGE Operating instructions Visualisation airtelligence provis 2.0 Page 5


After the eligibility of the request has been verified, you will receive a verification code via email. 

7. Enter the verification code in the empty field in the “Activation window”.  

8. Click on the “Activate” button.  

From now on, the full range of functions of the airtelligence provis 2.0 will be at your disposal. 

Paste 

4. The functions of the full version 
After activating the full version, you will have a wide range of new functions at your disposal. 
These are explained in detail below. 

4.1. History – Reporting  
The reporting screen shows the runtime data and the evaluation of this data in the form of tables. 
The structure of this screen is explained in detail below. 

Page 6 BOGE Operating instructions Visualisation airtelligence provis 2.0


Data selection: 

In the upper section, you can select the segment that you wish to view. The default segment, for 
the current period, is selected as standard. In addition to selecting the report/evaluation 
timespan, you can also export the evaluation data for specific periods (e.g. yesterday, last week or 
last month) and save them as PDF or CSV files. 

It is also possible to have PDF reports sent automatically via email at defined intervals (to the 
user’s email address). Click on the “Report Intervals” button to open the corresponding, self‐
explanatory menu. 
 

Overview of key performance data: 

The second section of the screen shows some of the key performance data of the compressed‐air 
station for the selected timespan. The field on the left‐hand side (“Facility”), however, is an 
exception. Here, the current status data is shown, so that you do not lose sight of it. 

The P‐min and P‐max values represent the minimum and maximum pressure values that occurred 
during the report timespan. 
 

Compressor runtime information: 

 
This section of the screen lists all of the compressors that are connected to the system. The first 
columns show the performance data and the columns on the right show the operating hours and 
service counter. 

The values shown are independent of the selected report timespan, since they relate to current 
data as opposed to historical data. 

BOGE Operating instructions Visualisation airtelligence provis 2.0 Page 7


Evaluation:  

 
 

The bottom section of the screen shows the evaluation of the operating hours that occurred 
during the report timespan. The load and idle times of the compressors are added together for 
this purpose. Since the air delivery quantity and the input power 
of the compressors are known, the generated quantity of 
compressed air can be calculated, along with the amount of 
electrical energy consumed and thus also the resulting costs. If 
you click on an individual value, a separate window opens to 
show a diagram based on the corresponding column values. 

4.2. Facility Alarms 
The Facility Alarms screen allows you to configure email notifications for alarm messages and out‐
of‐range values.  

 
 
This can be done as follows: 

1. Select and create the type of alarm. 
2. For range alarms, enter the permissible range of values. 
3. For compressor or accessory alarms, define the alarm context. 

The following table shows an overview of the entry options: 

Page 8 BOGE Operating instructions Visualisation airtelligence provis 2.0


  Alarm type  Value(s)  Alarm Context 
Facility alarms  Status alarm  Warning level 1  Facility 
Warning level 2 
Warning level 3 
Error 
Pressure range alarm  Range of values in  Facility 
[programmed unit 
of pressure 
measurement] 
Compressor alarms  Final compression  Range of values in  “All 
temperature  [programmed  Compressors” 
temperature unit] 
or individual 
Compressor warning  No limitation  selection  
Compressor error  No limitation 
Accessory alarms  Accessory error  No limitation  “All 
Accessories” 
or individual 
selection  
Accessory range alarm  Range of values in  Individual 
[programmed unit  selection from 
of measurement]  the connected 
accessories 

BOGE Operating instructions Visualisation airtelligence provis 2.0 Page 9


4.3. Settings – Notifications  
The notifications section allows you to set the parameters for sending notifications via email. Up 
to three different email recipients can be entered in the “Alarm Settings” section. 

The details of your SMTP server must be entered in the “Email Settings” section, so that the 
application can send emails. The address of the sender can be freely selected  
(example: [email protected]). 

4.4. Settings – User Management  
Users that are defined as standard and cannot be deleted: 

User name  Password 

Master  Master 

System  System 
 
With the “Master” user, you can create new users and also change all the other settings (with one 
exception, which is reserved for the “System” user). This user cannot be deleted.  

The “System” user role permits the following setting adjustments, which apply to the entire 
visualisation application and are user‐independent. 

‐ The language set by this user is the language in which alarms and reports are written.  

‐ Only the “System” user can set the currency unit and the price per kWh. Otherwise, this user has 
no further functions. 

Page 10 BOGE Operating instructions Visualisation airtelligence provis 2.0


Create a new user 

To create a new user, you will need to log in as “Master”: 

1. Click on “New User” in the Settings/User Management section.  

2. Enter the user data in the corresponding fields.  

 
The password can be freely selected; no restrictions apply. Then select a role for the user. Each 
role has certain access rights. The following table shows the various restrictions for each user role. 

Role   Disabled areas 

Administrator  User Management and Data Segmentation 

Controller  Alarms, Notifications, User Management and Data Segmentation 

User  Evaluation, Alarms, Notifications, User Management and Data Segmentation. 
 

The “Login enabled” check box is used to determine whether it is possible to login using this user 
data. This allows you to deactivate programmed users without having to delete them. Only the 
Master user can not be deactivated. 

BOGE Operating instructions Visualisation airtelligence provis 2.0 Page 11


4.5. Create new segment 
Data Segmentation refers to the subdivision of data into different, named, chronological 
segments. This can be useful if the facility configuration is changed and a direct comparison 
between the previous and current data is no longer meaningful. For analysis purposes, however, 
it may still be useful to keep the old data in the system and to simply segment access to it. Since 
the visualisation application always accesses only the currently selected segment, the processing 
speed can be increased by applying segmentation on a regular (e.g. annual) basis. 

A new segment can be created as follows:  

1. In the “Endtime” field, enter the date and time that defines the end of the new segment. Make 
sure that you use the specified format. 

2. In the “Segment Name” field, enter a freely defined name for the segment. 

3. Click on the button     to complete this action. 

In the History section, you can now choose between the newly generated segment and the 
standard “Default” segment (which contains the current runtime data). 

Page 12 BOGE Operating instructions Visualisation airtelligence provis 2.0