INTRODUCTION
The purpose of this document is to help service workshop technicians to service products. This service
manual must be used only by authorized service suppliers. The content of it is confidential. Please note
that provides other guidance documents for service suppliers. Follow these regularly and comply with
CAUTIONS
Please refer to the phone’s user’s guide for instructions relating to operation, care, and maintenance,
which include important safety information.
1 Servicing and alignment must be undertaken by qualified personnel only.
2 Ensure all work is carried out at an anti-static workstation and that an anti-static wrist strap is
worn.
3 Use only approved components as specified in the parts list.
4 Ensure all components, modules, screws, and insulators are correctly re-fitted after servicing and
alignment
5 Ensure all cables and wires are repositioned correctly electrostatic discharge can easily damage
the sensitive components of electronic products. Therefore, every service supplier must observe the
precautions which mentioned above.
1 Make sure your testing equipment is functioning properly before beginning repair work.
2 Before starting repairs you must observe ESD precautions such as being in your ESD protected
area and connecting your wristband.
3 Use gloves to avoid corrosion and fingerprints.
4 Cover windows and displays with a protective film to avoid dust and scratches.
5 Use a lint-free cloth to clean the LCD.
6 When cleaning the pads use a soft cloth\ESD brush and isopropanol. Do not use a glass fiber
pencil: this scratches the surface and will corrosion.
7 Non-faulty mechanical parts(except shielding lids and bent parts or soldered components).May be
reused if they are not soldered.
8 When removing the shielding lids make sure to replace them with new ones, otherwise the
high-frequency leakage can affect the device.
9 Always use the original spare parts.
10 Check the soldering joints of the parts concerned with regard to the fault symptom. And resolder
them if necessary.
11 Remove excess soldering flux after repair.
12 Observe the torque requirements when assembling the unit.
13 Please aware that some malfunctions may be software related and solved by an update
Chapter 1
SIM 1 Data
interface
SIM 2 Data
interface
Battery connector
To LoudSpeaker
Power Supply
Logic Ctrl
TX Signal To RF PA
Micro USB
CPU(MT6260)
T-Flash
RF PA
Card
SIM2
SIM1
Charge
Circuit
Instruction of SW update
1 1. Install the USB driver without the USB cable plugged into the computer.
2 After it is ok, plug the cable then check the device manager as the picture below:
1 You better choose auto format FAT in “Format FAT” like belows,
2 Tip Download Agent, choose MTK-ALLInOne.bin
8. Power on the phone and input“#*37#*”,check its version number on the first option.
FUNCTION TEST
Press “*#37*#” to check these items in stand by mode: