Single AP = 10 Gbps Office, security protection, production... High burst -> packet loss
Management, control,
and analysis High-quality bearer network ideal for Wi-Fi 6 era
Telemetry
Full-10GE access, releasing Wi-Fi 6 speed
NETCONF/YANG
Network layer • Multi-GE switch + high-density 25GE fixed switch + 100GE core, building ultra-broadband channels for Wi-Fi 6
• Integrated wireless policy management (managing up to 10k APs and 50k concurrent users), meeting massive
user concurrency in the Wi-Fi 6 era
• Wireless campus with 10k users, thanks to 100GE capable CloudEngine S12700E (57.6 Tbps, 50k wireless users, 6x
performance)
CloudEngine S series campus switches
25/100GE 25/100GE
VXLAN
Service Service
network 1 network 2
CloudEngine
S12700E-4
CloudEngine
CloudEngine S7700 CloudEngine
CloudEngine S5730-H/S S6730-H/S
S5735-S/L
CloudEngine
S12700E series
CloudEngine S12700E
3.2T - 4.8T bps/slot
Aggregation Switch
CloudEngine
S7700 series
S6700 series CloudEngine CloudEngine CloudEngine
CloudEngine S7700
S6730-H S6730-H S6730-S
160G-800G bps/slot
25GE down-link 10GE down-link 10GE down-link
Access Switch
CloudEngine
S5700 series
CloudEngine S5731-H/S CloudEngine S5732 CloudEngine S5735-S CloudEngine S5736-S
GE down-link GE/Multi-GE down-link GE down-link Multi-GE down-link
CloudEngine S12700E-4/8/12
SFUE
CPU
USB ETH
BITS(Reserved) Console
USB-based ETH
NetConf/YANG Console
deployment Management
Subcard
SFUH(used in S12700E-4/8)
SFUE(used in S12700E-4/8)
SFUM(used in S12700E-12)
N+1 N+1
3.2Tbps/slot hot standby
4.8Tbps/slot hot standby
Extend card
• Support 100GE QSFP28 optical module(Port 0-1) and 40GE QSFP+ optical module(all port)
• Built-in programmable chips, supporting features such as Native AC, VxLAN, Free mobility
• MACSec
Note: The 40GE/100GE (X6E) interface cards can be used on both CloudEngine S12700 and S12700 chassis
X6E 24* - - - - - √ √ √ √
X6E/X6S 6* - - - - - √ √ √ √
X6E 2* 4 - - - - √ √ √ √
X6H - - 40 - - - √ √ √ √
X6E/X6S - - - 48 - - √ √ √ -
X6E/X6S* - - - 24 24 - √ √ √ -
X6E/X6S* - - - - 48 - √ √ √ -
X5E/X5S - - - - - 48 √ √ √ -
• The CMU manages power modules and fan modules in a chassis. The CMU is hot swappable. Two CMU cards can be
installed in a chassis to work in active/standby mode.
Input Voltage:
• AC: 90V AC~290V AC Input Voltage:
• DC: 190V DC~290V DC • -40V DC~-72V DC
Max Output Power: Max Output Power::
• 3000W@220V AC/240V DC • 2200W
• 1500W@110V AC
• Power supplies use a screw-free ejector latch for easy swapping. An indicator shows whether a power supply is securely installed in its slot.
• AC/DC power modules can be mixed in the same device.
Airflow:
Left-to-back airflow design, higher heat dissipation
efficiency in the rack
Hot swapping:
Other fan modules are not affected when you install or
remove a fan module
CloudEngine S7703/06/12
High-density, strong power supply capability, rich port forms, and flexible scenario adaptability
• Bidirectional bandwidth per slot: 320 Gbps (S7703), 800 Gbps (S7703 PoE)
• Integrates the control and monitoring functions, excluding the SFU (full mesh).
• Better performance than MCUD: 1024 APs (via native WAC), Improvements on ARP,
MCUD ND, and RIB entry specifications
• Bidirectional bandwidth per slot: 720 Gbps (S7706), 720 Gbps/320 Gbps (S7712) *
• Integrates hardware-based OAM/BFD, achieving millisecond-level network quality
detection
• Service port-based CSS ensures stable and reliable device running
• Used together with C-version line cards
• Cannot be used for capacity expansion or replacement of old MCUs on the live
SRUHX1
network
Note: When SRUHX1 is used on S7712, slots 6 and 7 are golden slots that provide higher bandwidth
X6E/X6S 6* - - - - - √ √ √ √
X6E 2* 4 - - - - √ √ √ √
X6E/X6S - - 48 - - - √ √ √ -
X6E/X6S - - 24 24 - - √ √ √ -
X6E/X6S - - - 48 - - √ √ √ -
X5E/X5S - - - - 48 - √ √ √ -
X5E - - - - - 48 √ √ √ -
2*100GE 4*40GE
• Support 100GE QSFP28 optical module(Port 0-1) and 40GE QSFP+ optical module(all port)
• Built-in programmable chips, supporting features such as Native AC, VxLAN, Free mobility
• MACSec
6 x 100GE
48 x 10GE
24 x 10GE 24 x GE
48 x GE
48 x GE PoE++
LSS7G48VX5E0
• Full PoE++
• In-house chip inside, supporting key features such as native WAC, VXLAN, free mobility
• Used on S7703 PoE and S7706 PoE chassis, with 60 W power supply on all ports
800W AC
1600W DC
2200W DC
3000W AC
S7712
S7703 PoE S7706 PoE
(PoE PS slot)
Power module structure 3 power modules (shared) 8 power modules (shared) 4 power modules
C
PS1-PS4 M PS5-PS8
U
PS1 PS2 PS3
S7703: PS3 is a PoE module. S7706/7712: PS5-PS8 is a PoE module.
S7703 PoE: All modules are PoE Module S7706 PoE: All modules are PoE Module
• The CMU manages power modules and fan modules in a chassis. The CMU is hot swappable. Two CMU cards can be installed in a chassis to
work in active/standby mode.
Input Voltage:
• AC: 90V AC~290V AC Input Voltage:
• DC: 190V DC~290V DC • -40V DC~-72V DC
Max Output Power: Max Output Power::
• 3000W@220V AC/240V DC • 2200W
• 1500W@110V AC
• Power supplies use a screw-free ejector latch for easy swapping. An indicator shows whether a power supply is securely installed in its slot.
• AC/DC power modules can be mixed in the same device.
C l o u d E n g i n e S 5 7 0 0 E C - H 4 8 T 4 Y C - M A
A B C D E F G H I J K L M
Location Meaning Description
A Brand name (1 bit) Fixed as S
B Network positioning (1 bit) 8: core switch; 6: aggregation switch; 5: access switch
C Market positioning (1 bit) 7: enterprise network market; 3: carrier market
The leftmost one bit indicates the generation, for example, 10/20/50.
D Switch series (2 bits)
The rightmost one bit indicates the specification upgrade, for example, 01/02/03.
E Industry identifier (1 or 2 bits) Null by default; EC: e-commerce model; S: channel distribution model.
F Series model (1 bit) H: high-end model; S: standard model; L: lite model.
G Number of downlink ports (2 bits) Number of downlink ports
D: 400G; C: 100G; Q: 40G; Y: 25G; X: 10G optical; M: 10G electrical; N: 2.5G/5G electrical; S: GE optical; T: GE electrical; F: FE
H Downlink port type (2 bits) electrical; P: GE electrical port, supporting PoE; U: GE electrical port, supporting PoE++; UM: multi-GE port, supporting
PoE++.
I Number of uplink ports (1 bit) Number of uplink ports
J Uplink port type (2 bits) D: 400G; C: 100G; Q: 40G; Y: 25G; X: 10GE optical; S: GE optical; T: GE electrical; TP: combo port.
K Card slot (1 bit) Null: Cards are not supported; C: Uplink cards are supported.
Null by default; If there is a value (for example, M or I) for this bit, the switch is a dedicated one. M indicates a switch
L Dedicated bit (1 bit)
tailored for video surveillance scenarios, and I indicates an extended-temperature switch.
Type of power supply delivered by
M A: AC power supply; D: –48 V DC power supply; null: no power supply delivered by default.
default
Product Positioning:
Aggregation switches on large- and medium-sized enterprise campus networks support 10GE/25GE access and 40GE/100GE
uplink, effectively reducing the network convergence ratio.
Core switches on small- and medium-sized enterprise campus networks help enterprises build a simplified two-layer
access+core network. The access network is connected to the core network through 25 Gbit/s.
Networking:
Wireless campus : Wi-Fi 6 AP+ S5732-H MultiGE + S6730-H
Elastic bearer network : S5732-H MultiGE (RTU) + S6730-H (RTU) + S12700E (RTU)
* Right To Use (RTU): The rate of down-link port can be upgraded through licenses.
Model Picture
S6730-H
28 x 25 Multi-GE ports, 100 x 25GE optical ports
25GE switch
S6730-S
24 x 10GE optical ports, and 6 x 40GE optical ports
10GE Switch
Benchmarking Model
HW:S6730-H 25GE/10GE switch CISCO:C9500
HW:S6730-S 10GE switch CISCO:C9500
Hardware stacking
reliability
Fan redundancy
PSU redundancy
O&M Netconf/YANG
Telemetry
Netstream
PTP:1588v2
Security MACSec
WAC WAC
User NAC
management
Free mobility
Virtualization VXLAN
VPN MPLS
Console
28 x 25GE 4 x 100GE
MEth
28 x 25 Multi-GE ports, 100 x 25GE optical ports
• VXLAN-based automatic virtual network deployment, • Telemetry, second-level data collection, visualized and
implementing multi-purpose network intelligent O&M
CPU: RAM:4GB
Console 6*40GE/100GE
4 Core*1.4GHz Flash:2GB
Console
24 x10GE 4 x 25GE 4 x 100GE
MEth
24*10Goptical ports, and 4*25G+4*100GE optical ports Note:MACSec support(0-7 down links,2-3 up links)
VXLAN-based automatic virtual network deployment, Telemetry, second-level data collection, visualized and
implementing multi-purpose network intelligent O&M
S5732-H 24 x Multi-GE + 24 x 10GE SFP+ ports, 4 x 25GE optical ports + 2 x 40GE opt
Hybrid Optical-Electrical Switch ical ports or 2 x 100GE optical ports
S5732-H 24/48 x Multi-GE ports, 4 x 25GE optical ports + 2 x 40GE optical ports or 2
Enhanced GE x 100GE optical ports
S5732-H
S5731-H
S5731-S
S5736-S *
S5735-S
S5735-L
Benchmarking Model
*Hardware ready
ETH management port Four slots for pluggable Two slots for pluggable power modules
SSD card slot*
USB 2.0 port fan modules (1+1 redundancy), supporting 600 W AC or
1000 W DC power modules
Note: The 4 x 25GE ports can auto-sense 10GE and 25GE according to the SFP model. The 4 x 25GE ports can be configured to work at 1GE SFP. In this case, all the 4 ports
work at 1GE. If the 4 x 25GE ports are used, the 2 x 40GE ports cannot operate at 100GE. A 40GE QSFP+ optical port can be split into 4 x 10GE SFP+ ports with breakout cable.
Category 5 cable
• 10GE optical fiber access, meeting Wi-Fi needs 1/2.5G 100 m (industry average) None
(CAT5E)
in the next 10 years
Category 6
1/2.5/5G 100 m (industry average) None
cable (CAT6)
Hybrid optical-
1G/10G 300 m Smooth upgrade
electrical cable
Application scenario: AP access distance is greater than 100 m, where power supply is difficult and cabling costs are high. Hybrid
optical-electrical cables are deployed once, while smoothly upgrading to 25G/40G/100G.
Note: The S5735-L48P4X-A has one built-in pluggable 1000 W AC power module.
Console port
Built-in ASIC 1.2 GHz quad-core Memory: 2 GB 4 x 10GE
ETH management
chip CPU Flash: 1 GB ports
port
Stack bandwidth:
MAC address: 32K
480 Gbps 24 x Multi-GE electrical ports(10Gbps capable) and 4 x 10GE
optical ports
90W PoE++,Meeting requirements for ultra-high Provides power module and fan module redundancy design,
power supply ensuring reliable device running
220 V AC input
12 V DC output
24 V AC output
Circuit Fiber
breaker management Access control sensor
(input/output) tray
Model 2 x 40GE QSFP+ card 8*10GE Base-T card 8*10GE SFP+ card* 8*25GE SFP28 card**
S5732-H
- - √ √
Multi-GE Model
S5732-H
- - √ √
Hybrid Optical-Electrical Model
S5731-H √ √ √ -
*Note: The 8*10GE card supports 2*25GE SFP28 (ports 0 and 1) through mode switching, and all ports support MACsec.
**Note: The 8*25GE card supports 10GE/25GE auto-sensing, GE optical interfaces (CLI), and all ports support MACsec.
AC input
90 V AC to 264 V AC 90 V AC to 264 V AC 90 V AC to 290 V AC N/A N//A 90 V AC to 290 V AC
voltage
AC input
47 Hz to 63 Hz 47 Hz to 63 Hz 45 Hz to 65 Hz N/A N//A 45 Hz to 65 Hz
frequency
High-voltage
190 V DC to 290 V DC N/A 190 V DC to 290 V DC N/A N//A 190 V DC to 290 V DC
DC
DC input
N/A N/A N/A –38.4 V DC to –72 V DC –38.4 V DC to –72 V DC N/A
voltage
Power S6730-H S6730-S S5735-L S5735-S S5735-S-I S5736-S S5731-S S5731-H S5732-H
Module
Type All model All model
48-Port PoE
PoE Model
48-Optical- Other Multi-GE
PoE Model
Non-PoE
PoE Model
Non-PoE Optical Multi-GE
Model Port Model Models Model Model Model Model Model
60 W AC - - - - - √ √ - - - - - - -
150 W AC - - - - √ - - - - √ - √ - -
600 W AC √ √ - - - - - - - √ - √ √ -
1000 W
AC - - √ √ - - - √ √ - √ - - √
180 W DC - - - - √ √ √ - - √ - √ - -
1000 W
DC √ √ - - √ √ - - - √ - √ √ -
Note: The table is for reference only. For the mapping between product models and power modules, see the latest brochure on the official website and the configurator
SCT.
Fan Fan
module module
slot 1 slot 2
Pluggable
fan module
FAN-031A-B FAN-023A-B (Air Out) FAN-031A-F (Air In) Remarks
S5731-H48T4XC-B -- -- Supported
• Used for GE,10GE,25GE optical port stacking • Used for 40GE,100GE optical port stacking • Used for GE,10GE,25GE optical port stacking • Used for 40GE,100GE optical port stacking
• Four types: 1 m, 3 m, 5 m, 10 m • Three types: 1 m, 3 m, 5 m • Two types: 3 m, 10 m • One type: 10 m
Type 3: fiber patch cord + optical module Type 4: dedicated stack cable
plug-and-play
SFP SFP+ SFP28 QSFP+ QSFP28
0.5 m or 1.5 m
3. Used on CloudEngine S5731-H/S series switches
• HQos
• Native AC
• Free Mobility
Network
• VxLAN
Automation
Service
Enhancement
Highlight
High • iStack
Reliability • BFD Security
• eMDI
• MacSec
Border
Edge Edge
Office Videoconf Security Office Videoconfe Security Office Office Videoconferencing Videoconferencing Security Security
erencing protection rencing protection protection protection
Huawei Huawei
or 3rd vendor or 3rd vendor
VxLAN
Edge A (BGP-EVPN) Edge B
VxLAN
(BGP-EVPN)
Office PC IPC Conference TE Office PC Conference TE IPC Office PC IPC Conference TE Office PC Conference TE IPC
• Application scenario: network reconstruction and upgrade, supporting • Application scenario: applicable to new deployment or reconstruction
hybrid deployment (access) of devices from different vendors; scenarios and supports hybrid deployment of 3rd party devices
• Solution highlights: The existing access devices are reused to maximize • Solution Highlights: Reuse of Some Aggregation Devices, Protecting
the return on investment (ROI) of the live network Investment on the Live Network, and Network-wide Virtualization
Eth-Trunk
Eth-Trunk
• Eth-Trunk uplink aggregation and
iStack load balancing improve uplink
iStack
reliability.
cable
each logical stack port supports one or more physical ports of the
same type.
Logical stack port 1
• High-speed cables, AOC cables, optical fibers+optical modules, and
dedicated stack cables can be used as stack cables. In particular,
Logical stack port 2 dedicated stack cables support plug-and-play and do not require
service configuration.
For details about the stack cable type, see the CloudEngine Series
Switches Stack Cables.
Note: The CloudEngine S12700E supports CSS based on service ports, and the S7706 and S77012 support CSS
based on service ports to ensure reliability of core nodes and simplify device management.
RIP/OSPF/IS-IS
Multi-hop
detection
• Hardware-Based OAM/BFD provides 3.3 ms detection • Upon a network-level fault, a switchover can be completed
interval. It helps quickly detect the link status. within 50 ms, with user services not affected.
Innovative eMDI detects and locates audio/video service faults in real time
CampusInsight
KPI collection flow
9 8 7 6 5 3 2 1 VCN
IPC2
Forwarding
bottleneck
Core Core Native
WAC
AC
Access Access
Native AC √ √ √ √ √ √ √ √ √ √
AP
management
10K 512 1K 1K 1K 4K 4K 1K 1K 1K
capacity
(Total)
AP
management
4K 512 1K 1K 1K 4K 4K - - -
capacity
(X-series LPU)
Note: The SRUH of the CloudEngine S7706/12 includes three models, SRUH, SRUHA1 and SRUHX1.
iMaster NCE
1. Define security groups and policies 8 Mbps
2. Automatically translate and
deliver policies Terry
Mark
3. Authenticate users 4. Match and enforce policies
2 Mbps
1 Mbps
Guest 3 Guest √ x x x
Guest
Security group 2 Security group 1 Security group 3 Security group 2 Security group 3 CISCO TrustSec does not support
(R&D) (VIP) (guest) (R&D) (guest)
R&D 2 R&D √ × √ √
Security group 6
(email) Guest 3 Guest √ x x x
IP-Group Finance 5 Finance × √ √ ×
Synchronization ... ... ... ... ...
Security group 7
(R&D)
• The authentication points and policy execute point are
different devices.
VIP
Guest
Security group 2 Security group 1 Security group 3 Security group 2 Security group 3
(R&D) (VIP) (guest) (R&D) (guest)
Guest 3 Guest √ x x x
VIP
VXLAN tunnel
Sales
Security group 2 Security group 1 Security group 3 Security group 2 Security group 3
(R&D) (VIP) (guest) (R&D) (guest)
Data center
Policy Execute Point Security group Security group
definition policy matrix
Authentication Point
Security Group Group Policy (Permission)
Security group 5
(finance) Group Name SG ID Extranet Finance Email R&D
VIP 1 VIP √ √ √ √
R&D 2 R&D √ × √ √
Security group 6 Core
Guest 3 Guest √ x x x
(email)
Finance 5 Finance × √ √ ×
VIP
Sales
Security group 2 Security group 1 Security group 3 Security group 2 Security group 3
(R&D) (VIP) (guest) (R&D) (guest)
Port
User
Network-wide secure transmission of Layer 2 packets MACsec: Layer 2 data encryption technology
Data source
Data frame
MACsec authenticity
integrity
LAN verification
check User data Replay
MACsec protection
encryption
Note: MACsec is enabled on the uplink ports (fixed ports or ports of cards) of
Area A Area B Area C
access switches and ports of aggregation devices, and on the uplink ports of
aggregation devices and ports of core devices to provide end-to-end secure
transmission channels.
MACsec √ √ √ √ √ √ √ √ √ √
Encryption MACsec-
MACsec-256 MACsec-256 MACsec-256 MACsec-256 MACsec-256 MACsec-256 MACsec-256 MACsec-256 MACsec-256
Technology 256
Fixed
S6720-SI CloudEngine S6730-S
(10GE)
S6720-LI CloudEngine S5732-H(Multi-GE)
S5720I-SI
CloudEngine S5735-S-I(24 Port)
Extended-Temperature Switch
CloudEngine S6730-H
Aggregation
Catalyst 9500
CloudEngine S6730-S
S7700
Catalyst 9400
CloudEngine S5732-H
CloudEngine S5736-S
Catalyst 9300
CloudEngine S5731-H
Access
Catalyst 9300L CloudEngine S5731-S
Product Overview
https://e.huawei.com/en/products/enterprise-networking/switches
Campus-network Solution
https://e.huawei.com/en/solutions/business-needs/enterprise-network/campus-network
Product Document
https://support.huawei.com/enterprise/en/category/switches-pid-1482605678974?submodel=doc