0% found this document useful (0 votes)
123 views1 page

FGC Simulation

The document contains data from 12 streams (S1-S12) and 3 heat exchangers (ECONOMISER, EVAPORATOR, SUPERHEATER) in a power plant. It includes properties like temperature, pressure, enthalpy, and mass flow rates of each stream as well as duties, areas, heat transfer coefficients and LMTD values for each heat exchanger. The streams consist of water, vapor, or mixed phases and transfer heat and mass between the heat exchangers in the order of ECONOMISER, EVAPORATOR and SUPERHEATER.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
123 views1 page

FGC Simulation

The document contains data from 12 streams (S1-S12) and 3 heat exchangers (ECONOMISER, EVAPORATOR, SUPERHEATER) in a power plant. It includes properties like temperature, pressure, enthalpy, and mass flow rates of each stream as well as duties, areas, heat transfer coefficients and LMTD values for each heat exchanger. The streams consist of water, vapor, or mixed phases and transfer heat and mass between the heat exchangers in the order of ECONOMISER, EVAPORATOR and SUPERHEATER.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

S4

S2
S7 S10

Stream Name S1 S10 S2 S3 S4 S5 S6 S7 S8 S9 S11 S12


S6 Stream Description
Phase Mixed Water Vapor Vapor Vapor Water Vapor Vapor Vapor Mixed Vapor Water
Temperature C 274.3388 150.0000 214.5727 253.0000 454.0000 120.0000 498.7970 601.0000 196.7539 252.8533 274.3388 274.3388
Pressure KG/CM2G 58.9884 58.9884 0.0468 41.5000 40.0000 59.0000 0.0584 0.0700 -0.6532 41.5000 58.9884 58.9884
SUPERHEATER EVAPORATOR Enthalpy M*KCAL/HR 26.5401 6.0899 29.2442 12.8966 47.0603 4.8653 49.6944 57.4337 28.0196 39.3210 26.4244 0.1157
ECONOMISER Molecular Weight 18.0153 18.0153 29.1244 18.0153 18.0153 18.0153 29.1244 29.1244 29.1244 18.0153 18.0153 18.0153
Vapor Weight Fraction 0.9900 0.0000 1.0000 1.0000 1.0000 0.0000 1.0000 1.0000 1.0000 0.9945 1.0000 0.0000
Liquid Weight Fraction 0.0100 1.0000 0.0000 0.0000 0.0000 1.0000 0.0000 0.0000 0.0000 0.0055 0.0000 1.0000
Total Mass Rate KG/HR 40115.000 40115.000 260063.000 19280.000 58993.850 40115.000 260063.000 260063.000 260063.000 58993.850 39713.850 401.150
S8 S5 Total Weight Comp. Rates KG/HR
H2O 40115.0000 40115.0000 20675.0085 19280.0000 58993.8500 40115.0000 20675.0085 20675.0085 20675.0085 58993.8500 39713.8500 401.1500
CO2 0.0000 0.0000 57785.9986 0.0000 0.0000 0.0000 57785.9986 57785.9986 57785.9986 0.0000 0.0000 0.0000
CO 0.0000 0.0000 26.0063 0.0000 0.0000 0.0000 26.0063 26.0063 26.0063 0.0000 0.0000 0.0000
SO2 0.0000 0.0000 26.0063 0.0000 0.0000 0.0000 26.0063 26.0063 26.0063 0.0000 0.0000 0.0000
N2 0.0000 0.0000 178533.2495 0.0000 0.0000 0.0000 178533.2495 178533.2495 178533.2495 0.0000 0.0000 0.0000
S1 O2 0.0000 0.0000 3016.7308 0.0000 0.0000 0.0000 3016.7308 3016.7308 3016.7308 0.0000 0.0000 0.0000

S9

HxRig Name ECONOMISEREVAPORATOR


SUPERHEATER
HxRig Description
Duty M*KCAL/HR 1.2246 20.4502 7.7393
Area M2 42.9537 1460.8029 86.5861
Area (Required) M2 38.4077 1432.6110 67.0559
S11 U-Value (Clean) KCAL/HR-M2-C 943.9476 350.9306 1295.1000
U-Value (Required) KCAL/HR-M2-C 411.9828 245.9547 470.1390
U-Value (Fouling) KCAL/HR-M2-C 460.7453 250.7948 607.0683
S3 LMTD C 70.4880 59.3804 194.7356
FT Factor 0.9818 0.9585 0.9763