1
Basic Package (BINARY VERSION)
Master Query Package (HOST)
Field Header Address Query Function Data length DATA BYTES Error Check
Desc SOH 0~255 0~255 0~255 CRC16_Low CRC16_Hi
Size 1 BYTE 1 BYTE 1 BYTE 1 BYTE 0~255 BYTES 1 BYTE 1 BYTE
Note:
SOH = 01h.
Address = Device Address (Slave Machine ID)
Slave Response Package (DEVICE)
Field Header Address Response Function Data length DATA BYTES Error Check
Desc SOH 0~255 ACK / NAK / EVN 0~255 CRC16_Low CRC16_High
Size 1 BYTE 1 BYTE 1 BYTE 1 BYTE 0~255 BYTES 1 BYTE 1 BYTE
Note:
SOH = 01h.
Address = Device Address (Slave Machine ID)
ACK = 06h, Acknowledge (Passive, in response to Master message)
NAK = 15h, Negative Acknowledge (Passive, in response to Master message)
EVN = 12h, Event Message(Active, For One Host to One Device Connection)
2
The Query - Response Cycle (Passive)
The Query
The function code in the query tells the addressed slave device what kind of action to perform. The data bytes
contain all additional information that the slave will need to perform the function. The error check field
provides a method for the slave to validate the integrity of the message contents.
The Response
If the slave makes a normal response, the function code in the response is an ACK of the function code in the
response. The data bytes contain the data collected by the slave, such as register values or status. If an error
occurs, the function code is NAK to indicate that the response is an error response, and the data bytes
contain a code that describes the error. The error check field allows the master to confirm that the message
contents are valid.
Avoiding Collision And Synchronizing (optional)
1. Send Package: Must have a 2 byte interval (by baudrate) after end of receiving.
2. Receive Package: If package is cut off (unfinished) and exceeds the interval, receiver can discard and
reset the unfinished package buffer.
Query Package 2 Byte interval Response Package
3
Byte sequence for data type INTEGER or LONG in "DATA BYTES" field
Example for data type integer 261Bh (2 BYTES)
SOH Address Function Data Length (MSB) Data Bytes (LSB)
2 26h 1Bh
Example for data type long 261B3C27h (4 BYTES)
SOH Address Function Data Length (MSB) Data Bytes (LSB)
4 26h 1Bh 3Ch 27h
Example for data structure:
Structure _example
Byte bCode = 2Ch;
Int nValue = 261Bh;
Long lValue = 261B3C27h;
SOH Address Function Data Length (MSB) Data Bytes (LSB)
bCode nValue lValue
7 2Ch 26h 1Bh 26h 1Bh 3Ch 27h
4
Generating a CRC
Step 1 Load a 16-bit register with FFFF hex (all 1's). Call this the CRC register.
Step 2 Exclusive OR the first eight-bit byte of the message with the low order byte of the 16-bit CRC
register, putting the result in the CRC register.
Step 3 Shift the CRC register one bit to the right (toward the LSB), zero filling the MSB. Extract and
examine the LSB.
Step 4 If the LSB is 0, repeat Step 3 (another shift). If the LSB is 1, Exclusive OR the CRC register with the
polynomial value A001 hex (1010 0000 0000 0001).
Step 5 Repeat Steps 3 and 4 until eight shifts have been performed. When this is done, a complete eight-bit
byte will have been processed.
Step 6 Repeat Steps 2 ... 5 for the next eight-bit byte of the message. Continue doing this until all bytes have
been processed.
Result The final contents of the CRC register is the CRC value.
Step 7 When the CRC is placed into the message, its upper and lower bytes must be swapped as described
below.
Note: GNetPlus CRC16 is for fields from "Address" to "Data Bytes".
Placing the CRC into the communication package
When the 16-bit CRC (two eight-bit bytes) is transmitted in the message, the low order byte will be
transmitted first, followed by the high order byte:
CRC16 Generation Function (C Code)
unsigned short GNetPlusCRC16(unsigned char *pBuffer, int iDataLen)
{
const CRC_PRESET=0xFFFF;
const CRC_POLYNOM=0xA001;
unsigned short nCRC16=CRC_PRESET;
char i;
while( iDataLen-- )
{
nCRC16 ^= *pBuffer;
pBuffer++;
for( i=0; i<8; i++)
{
if( (nCRC16 & 1)==1 )
nCRC16 = (nCRC16>>1) ^ CRC_POLYNOM;
else
nCRC16 = (nCRC16>>1);
}
}
return nCRC16;
}
5
Common Query Function Code Table (00h~1Fh)
Query (Master) Response (Slave)
Desc Func Len Data Bytes Func Len Data Bytes
Polling 00h 0 ACK n Return OEM Status
Get Version 01h 0 ACK n Return OEM Version String
Set Slave Addr 02h 1 New Address (1~255) ACK 0
Logon 03h n OEM Password ACK 0
Logoff 04h 0 ACK 0
Set Password 05h n OEM New Password ACK 0
Class Name 06h 0 ACK n Return Class Name
1
Set Date/Time 07h 7 GNET_DATETIME Structure ACK 0
Get Date/Time 08h 0 ACK 7 GNET_DATETIME Structure
2 3
Get Register 09h 3 Reg.Address + Reg.Len ACK n Reg.Block
Set Register 0Ah n Reg.Address + Reg.Buffer ACK 0
Record Count 0Bh 0 ACK 2 Record Count (Integer)
Get First Record 0Ch 0 ACK n First Record
Get Next Record 0Dh 0 ACK n Next Record
Erase All Records 0Eh 0 ACK 0
Add Record 0Fh n Record ACK 0
Recover All Records 10h 0 ACK 0
DO 11h 2 DO# + STATUS(0 or 1) ACK 0
DI 12h 1 DI# ACK 1 DI STATUS
Analog Input 13h 1 Channel# ACK 2 Value (Integer)
Thermometer 14h 0 ACK 2 Value (Integer)
Reserve 15h
Reserve 16h
Reserve 17h
Reserve 18h
Enable Auto Mode 19h 1 Boolean ACK 1 Result
OEM
Get Time Adjust 1Ah 0 ACK 4 Time Adjust Value (long)
Echo 1Bh N Any Data ACK n Master Data
OEM
Set Time Adjust 1Ch 4 Time Adjust Value (long) ACK 0
Debug 1Dh 0 ACK n OEM Debug Message
Reset 1Eh 0 ACK 0
Go To ISP 1Fh 0 ACK 0
Note:
1. GNET_DATETIME Structure (7 BYTES)
BYTE Second;
BYTE Minute;
BYTE Hour;
BYTE DayOfWeek;
BYTE Day;
BYTE Month;
BYTE Year;
2. Reg.Address: Integer Type(2 Bytes), Range 0000h~FFFFh.
3. Reg.Len : Register Block Size (1 Byte), Max.255.
6
Response NAK Code Table (Common)
Func Len Data Bytes Description
NAK 1 E0h Access Denied
NAK 1 E4h Illegal Query Code
NAK 1 E6h Overrun, Out of record count
NAK 1 E7h CRC Error
NAK 1 ECh Query Number no support
NAK 1 EDh Out Of Memory Range
NAK 1 EEh Address Number out of range
NAK 1 EFh Unknown
Response Event (For Active Slave)
Active Response (Slave)
Desc Func Len Data Bytes
Event 12h n Customer Event Code or Data