REMOTE RECTIFIER MONITORING WITH INTERRUPTION

RUGGED, RELIABLE
AND TRUSTWORTHY.
The Elecsys Watchdog Scout is the most reliable solution for rectifier
monitoring and GPS synchronized current interruption. Rigorously
tested and field-proven to withstand voltage surges up to 7500V at
3500A, the Watchdog Scout thrives in the harshest environments
- even in high lightning strike areas. Available in a variety of
WATCHDOG
configurations, the Watchdog Scout is simple to install, programmable
SCOUT
on-site or over the web, and sets the industry standard for remote
Key Features:
monitoring of CP systems.
• Instant visibility to field
asset status and automatic
compliance report
generation.
• Surge protection tested
(conducted voltage test per
IEC 61000-4-5 specifications)
• 2-way cellular or satellite
telemetry options for reliable
APPLICATIONS on-demand communication
anywhere in the world
• AC power failure detection
24/7/365 continuous CP rectifier monitoring • Programmable over the air or
on-site using the front panel
LCD interface
• 24/7 data access and
Individual site, group, or system-wide GPS synchronized current
interruption control from any
interruption control web enabled device using
the powerful Elecsys Connect
web interface

Pulse-counter/accumulator for meter-reading applications

Digital, dry-contact status “tamper alarm” monitoring


REMOTE RECTIFIER MONITORING
MAJOR
WITH INTERRUPTION MARKETS

The Elecsys Watchdog Scout has more useful features than any rectifier OIL
monitor system on the market. This means more benefits for your cathodic
GAS
protection program.
WATER
Elecsys Watchdog Scout benefits:
• Programmable over the web or locally using the onboard LCD display ELECTRICAL
and navigation buttons
• “Fail-safe” dual relay current interruption capability
• Advanced, self-testing circuitry automatically verifies the channel
calibration to a known, stable voltage with every reading.
• Extremely reliable in very harsh settings (i.e. high voltage electrical
and lightning surges)

PRODUCT SPECIFICATIONS
Digital cellular
Communications Satellite
Modbus (RS232) RTU slave connection for use w/customer supplied SCADA data radio

Temperature: -30º C to +70º C (-20º C to +70º C in battery backup power mode)


Operating Environment Humidity: 0 – 95% non-condensing
Enclosure rating: NEMA 4X polycarbonate

WATCHDOG SCOUT
110-240VAC into included step-down transformer
IS THE MOST RELIABLE
Power Rechargeable backup battery for alarm notification of power failure
Power consumption: 7.2W @15V typical, 22.7W @15V transmitting and interrupting RECTIFIER MONITORING
SYSTEM I’VE EVER
WORKED WITH.
7” (17.7 cm) x 9” (22.9 cm) x 4” (10.2 cm) standard enclosure,
Enclosure or 14” (35.5 cm) x 12” (30.5 cm) x 6” (15.2 cm) integrated components enclosure
(integrated enclosure rated to 40 Amps maximum)

Outputs 2 relay control outputs

Manufactured in the USA


4 analog measurement channels
Inputs 2 digital dry-contact/pulse accumulator channels Copyright © 2021
1 AC detection probe input
Elecsys International

GPS synchronized
846 N. Mart-Way Ct.
Interrupter Module
Syncs with any GPS equipped interrupters Olathe, KS 66061
Relay system (rated to up to 100A max switching load)
Optional “Mercury free” solid state DC with mechanical bypass dual relay system
913-647-0158
www.elecsyscorp.com

Rectifier voltage input: Range = +/-200V, measurement accuracy better than +/- 100mV
Measurement Accuracy Rectifier current input: Range = +/-100mV, measurement accuracy better than +/- 100uV
Potential input: Range = +/-10V, measurement accuracy better than +/- 100uV

To learn more, please visit us at elecsyscorp.com or call 913-647-0158


ELEC-0027 DS 0721