TECHNICAL DATA
Type Code Multi-DENCO
Basic Unit
Example D M A 0 1 0 D P S I S 4 P E 1
Heat Exchanger
Product
Filter
Power Supply
Cooling System
Panel Configuration
Compressor Control
Humidifier
Range
Unit Size
Fan
Heating
Airflow Direction
D DENCO
M Multi-DENCO
A Air cooled
C Chilled water
X Split system
010 Size 010
018 Size 018
030 Size 030
045 Size 045
065 Size 065
092 Size 092
130 Size 130
D Downflow
U Upflow
P Front full height panel
F Front air inlet grille panel
L Front low level air discharge panel
S Standard heat exchanger
L Large heat exchanger
C CombiCool
I Inverter compressor scroll
F Fixed speed compressor scroll
N Not fitted
S Steam humidifier standard conductivity
L Steam humidifier low conductivity
H Steam humidifier high conductivity
N Not fitted
4 Filter G4
7 Filter F7
2 Filter washable G2
P EC plug fan
E Electric heating
T Modulating electric heating
W Hot water heating
R Remote signal 0-10 V
N Not fitted
1 3~ 400 V, N, PE, 50 Hz
7 3~ 400 V, N, PE, 60 Hz
NOTES!
Full selection typecode available on page 40.
Some options are only available in certain regions. Full type code is displayed above and particular com-
binations of options are not feasible. For further details please contact your local office.
FläktGroup reserves the right to modify/change/amend and update design and options without prior
notice.
PROTECTION NOTICES
The reproduction, distribution and utilization of this document as well as the communication of its contents to others without express
authorization is prohibited. Offenders will be held liable for the payment of damages. All rights reserved in the event of the grant of
a patent, utility model or design.
The Multi-DENCO range utilises inverter technology in the compressors to ensure that
no energy is wasted in achieving the cooling demand of the room.
The compressors used in either a single compressor or tandem operation.
A-Version
010
C-Version
CombiCool
A-Version
018
C-Version
CombiCool
A-Version
030
C-Version
CombiCool
A-Version
045
C-Version
CombiCool
A-Version
065
C-Version
CombiCool
A-Version
092
C-Version
CombiCool
A-Version
130
C-Version
CombiCool
Pic. 1: Data calculated using 24 °C Supply Temperature, 45 % Relative Humidity, 45 °C Condensing Temperature.
FläktGroup reserves the right to modify data without prior notice.
* Airflow only valid for A-Version units. Other versions may vary.
Min Max
°C °C °C
A-Version 10 30 63
C-Version 10 40 N/A
CombiCool 10 40 63 / N/A
Cabinet
The cabinet is made of aluminium profile frame painted black connected together using
aluminium triangular gussets and white laminate panels that are removable using a
screwdriver to allow access.
The front curved doors are hinged, but removable and houses the touchscreen display
in standard configuration.
The panels are insulated according to "O" class using non-eroding material and pro-
vide both acoustic and thermal insulation.
Cooling Coil
Inclined, high performance coil with rippled aluminium fins, spaced at 1.8 mm.
Aluminium intermediate drip tray with a stainless steel condensate drain tray with
U trap.
For A-Version: Copper tubes 4 rows deep
For C-Version: 4 row and 6 row coils available
For CombiCool: 3 row / 3 row configuration used
(A-Version + CombiCool or C-Version + CombiCool)
Fans
Direct driven variable speed high efficiency EC plug fan with 7 backward curved three
dimensional profiled blades.
Impeller optimally balanced according to ISO1940 and fan speed modulates on stan-
dard settings.
Variable speed regulation is performed using a 0-10 V controller signal.
Electric Heaters
Units with electrical heating are equipped with sturdy sheated elements with stainless
steel finning and are rated to operate at black heat in order to prevent annealing con-
ditions and sparking.
Overheat protection is provided through a thermostat (Klixon).
The available heating duty is sufficient to prevent low supply temperatures in the dehu-
midification mode.
Air Filters
The filters have 30 % ASHRAE 52/76 standard, Eurovent 4/5, efficiency rate 90 %
(G4).
The filters are installed before the heat exchanger in the return air flow and are held by
quick release retaining clips/wire.
They are accessible from the front doors for replacement.
Humidifier
An electrode boiler humidifier can be installed into the bottom of the unit to allow humi-
dity to be controlled.
The humidifier generates steam using proportional regulation of untreated mains cold
water.
Electrode boiler humidifiers generate sterile, odourless and steam free of mineral
deposits.
The humidifier has an inlet hose connection and a water drain connection to remove
any remaining water.
Microprocessor Control
C5-12 capable of:
– Controlling temperature, humidity and performing auto-restart after power failure.
– Monitoring all digital and analogue inputs and outputs
– Acoustic alarms for issues with temperature, humidity, airflow, humidifier and com-
munication faults.
– Networking, sensor averaging and auto-changeover
Duty Required 2 % 100 100 70 100 100 70 100 100 70 100 100 70
Conditions
Relative Humidity % 50 40 40 50 40 40 50 40 40 50 40 40
Air Volume m3/h 2,993 2,993 2,095 5,148 5,148 3,604 8,640 8,640 6,048 12,722 12,722 8,905
Air Volume m3/s 0.83 0.83 0.58 1.43 1.43 1.00 2.40 2.40 1.68 3.53 3.53 2.47
Cooling Duty 1
Gross Total Capacity kW 10.1 10.7 7.6 18.6 18.6 12.8 30.6 30.2 21.6 45.2 45.2 32.6
Net Total Capacity kW 9.5 10.1 7.3 17.0 16.9 12.2 29.1 28.7 20.9 42.7 42.6 31.5
SHR 0.98 1.00 1.00 0.95 1.00 1.00 0.96 1.00 1.00 0.96 1.00 1.00
EER Indoor 3.63 3.80 4.15 3.17 3.37 4.23 3.78 3.97 4.85 3.59 3.73 4.26
Power Consumption
Power Consumption (Cooling) kW 3.0 3.0 2.0 6.3 5.9 3.4 8.9 8.4 5.2 13.7 13.2 8.7
Compressor(s) kW 2.2 2.2 1.5 4.3 3.9 2.4 6.6 6.1 3.8 10.1 9.6 6.6
Indoor Fans kW 0.6 0.6 0.3 1.6 1.6 0.6 1.5 1.5 0.7 2.5 2.5 1.0
Outdoor Fans 4 kW 0.2 0.2 0.2 0.4 0.4 0.4 0.8 0.8 0.8 1.1 1.1 1.1
Misc Data
Minimum Capacity kW 4 7 8 8
Maximum Capacity kW 15 25 38 54
Fan Quantity 1 1 1 1
Number of Compressors 1 1 1 2
Quantity 2 2 2 3
Depth mm 50 50 50 50
Connection Size
Humidifier Feed mm 15 15 15 15
3
Condensate Drain mm 22 2 x 22 2 x 22 2 x 22
Quantity 1 1 1 1
Refrigeration Circuits 1 1 1 1
NOTES!
Data is taken from downflow configuration and is representational of upflow arrangement.
1: Units operating with a 45°C condensing temperature.
2: Duty required is a % of the nominal, i.e. 100% = unit size in kW.
3: "2 x" referes to two seperate connections for condensate; only if humidifier is fitted. When there is no humidifier
then only 1 connection is used. When "2x" is not used, one common drain incorporates both types.
4: Outdoor unit used are examples for the conditions used in this dataset.
For details of all outdoor units available please refer to the next section of this document.
Conditions
Relative Humidity % 50 40 40 50 40 40 50 40 40
Air Volume m3/h 18,338 18,338 12,837 23,745 23,745 16,622 33,100 33,100 23,170
Air Volume m3/s 5.09 5.09 3.57 6.60 6.60 4.62 9.19 9.19 6.44
Cooling Duty 1
Gross Total Capacity kW 67.5 65.2 47.3 93.1 92.1 65.6 131.4 132.9 91.9
Net Total Capacity kW 63.4 61.1 45.6 85.8 84.9 62.8 120.7 122.1 87.7
SHR 0.95 1.00 1.00 0.94 1.00 1.00 0.94 1.00 1.00
EER Indoor 3.45 3.79 4.62 3.31 3.35 3.90 3.24 3.37 4.02
Power Consumption
Power Consumption (Cooling) kW 21.1 18.8 11.8 30.3 29.7 19.0 43.8 42.5 26.0
Compressor(s) kW 15.4 13.1 8.5 20.9 20.3 14.1 29.8 28.6 18.6
Indoor Fans kW 4.1 4.1 1.7 7.2 7.2 2.7 10.8 10.8 4.2
Outdoor Fans 4 kW 1.6 1.6 1.6 2.2 2.2 2.2 3.2 3.2 3.2
Misc Data
Minimum Capacity kW 8 18 25
Fan Quantity 2 2 3
Number of Compressors 2 2 2
Quantity 3 3 5
Depth mm 50 50 50
Connection Size
Humidifier Feed mm 15 15 15
3
Condensate Drain mm 2 x 22 22 22
Quantity 2 2 2
Refrigeration Circuits 1 1 1
NOTES!
Data is taken from downflow configuration and is representational of upflow arrangement.
1: Units operating with a 45°C condensing temperature.
2: Duty required is a % of the nominal, i.e. 100% = unit size in kW.
3: "2 x" referes to two seperate connections for condensate; only if humidifier is fitted. When there is no humidifier
then only 1 connection is used. When "2x" is not used, one common drain incorporates both types.
4: Outdoor unit used are examples for the conditions used in this dataset.
For details of all outdoor units available please refer to the next section of this document.
Duty Required 2 % 100 100 70 100 100 70 100 100 70 100 100 70
Conditions
Relative Humidity % 50 40 40 50 40 40 50 40 40 50 40 40
Air Volume m3/h 2,993 2,993 2,095 5,148 5,148 3,604 8,640 8,640 6,048 12,722 12,722 8,905
Air Volume m3/s 0.83 0.83 0.58 1.43 1.43 1.00 2.40 2.40 1.68 3.53 3.53 2.47
Cooling Duty 1
Gross Total Capacity kW 10.7 11.9 9.0 18.4 20.4 15.6 31.1 34.5 26.4 46.0 51.0 39.1
Net Total Capacity kW 10.1 11.2 8.7 16.8 18.8 15.0 29.6 33.0 25.7 43.5 48.5 38.0
SHR 0.94 1.00 1.00 0.94 1.00 1.00 0.94 1.00 1.00 0.94 1.00 1.00
Power Consumption
Power Consumption (Cooling) kW 0.6 0.6 0.3 1.6 1.6 0.6 1.5 1.5 0.7 2.5 2.5 1.0
Indoor Fans kW 0.6 0.6 0.3 1.6 1.6 0.6 1.5 1.5 0.7 2.5 2.5 1.0
Flow Rate m3/h 1.80 2.20 1.40 3.20 3.60 2.50 5.40 5.80 4.70 7.90 8.60 6.80
Flow Rate l/s 0.50 0.61 0.39 0.89 1.00 0.69 1.50 1.61 1.31 2.19 2.39 1.89
Other Data
Fan Quantity 1 1 1 1
Quantity 2 2 2 3
Depth mm 50 50 50 50
Connection Size
Humidifier Feed mm 15 15 15 15
Condensate Drain mm 22 22 22 22
NOTES!
Data is taken from downflow configuration and is representational of upflow arrangement.
Units are using a 3 way valve with bypass. Other options are available.
1: Units operating a 5K approach (7/12), 100% water with a standard coil.
2: Duty required is a % of the nominal, i.e. 100% = unit size in kW.
Conditions
Relative Humidity % 50 40 40 50 40 40 50 40 40
Air Volume m3/h 18,338 18,338 12,837 23,745 23,745 16,622 33,100 33,100 23,170
Air Volume m3/s 5.09 5.09 3.57 6.60 6.60 4.62 9.19 9.19 6.44
Cooling Duty 1
Gross Total Capacity kW 67.8 75.1 57.5 98.9 107.2 81.1 135.6 147.3 111.6
Net Total Capacity kW 63.7 71.0 55.8 84.0 100.0 78.3 124.8 136.5 107.4
SHR 0.94 1.00 1.00 0.92 1.00 0.99 0.93 1.00 0.99
Power Consumption
Power Consumption (Cooling) kW 4.1 4.1 1.7 7.2 7.2 2.7 10.8 10.8 4.2
Indoor Fans kW 4.1 4.1 1.7 7.2 7.2 2.7 10.8 10.8 4.2
Flow Rate m3/h 11.50 13.00 9.70 16.90 18.40 13.70 23.40 25.20 19.10
Flow Rate l/s 3.19 3.61 2.69 4.69 5.11 3.81 6.50 7.00 5.31
Other Data
Fan Quantity 2 2 3
Quantity 3 4 5
Depth mm 50 50 50
Connection Size
Humidifier Feed mm 15 15 15
Condensate Drain mm 22 22 22
NOTES!
Data is taken from downflow configuration and is representational of upflow arrangement.
Units are using a 3 way valve with bypass. Other options are available.
1: Units operating a 5K approach (7/12), 100% water with a standard coil.
2: Duty required is a % of the nominal, i.e. 100% = unit size in kW.
NOTES!
Data is taken from downflow configuration and is representational of upflow arrangement.
1: Units operating with a 45°C condensing temperature.
2: Units operating a 5 K approach (7/12), 100% water with a standard coil.
3: Duty required is a % of the nominal, i.e. 100% = unit size in kW.
4: "2 x" referes to two seperate connections for condensate; if humidifier is fitted. When "2x" is not used, one common
drain incorporates both typest.
5: Outdoor unit used are examples for the conditions used in this dataset. For details of all outdoor units available
please refer to the next section of this document.
NOTES!
Data is taken from downflow configuration and is representational of upflow arrangement.
1: Units operating with a 45°C condensing temperature.
2: Units operating a 5 K approach (7/12), 100% water with a standard coil.
3: Duty required is a % of the nominal, i.e. 100% = unit size in kW.
4: "2 x" referes to two seperate connections for condensate; if humidifier is fitted. When "2x" is not used, one common
drain incorporates both typest.
5: Outdoor unit used are examples for the conditions used in this dataset. For details of all outdoor units available
please refer to the next section of this document.
Duty Required 2 % 100 100 70 100 100 70 100 100 70 100 100 70
Conditions
Relative Humidity % 50 40 40 50 40 40 50 40 40 50 40 40
Air Volume m3/h 2,993 2,993 2,095 5,148 5,148 3,604 8,640 8,640 6,048 12,722 12,722 8,905
Air Volume m3/s 0.83 0.83 0.58 1.43 1.43 1.00 2.40 2.40 1.68 3.53 3.53 2.47
1
Cooling Duty
Gross Total Capacity kW 10.7 13.5 10.5 15.5 17.6 13.6 26.1 29.7 23.1 38.4 43.7 33.9
Net Total Capacity kW 10.0 12.8 10.2 13.7 15.9 13.0 24.4 28.0 22.4 35.7 41.0 32.8
SHR 0.94 0.88 0.83 0.96 1.00 1.00 0.96 1.00 1.00 0.96 1.00 1.00
3
Flow Rate m /h 1.80 2.16 1.80 2.52 2.88 2.16 4.32 5.04 3.96 6.48 7.56 5.76
Flow Rate l/s 0.50 0.60 0.50 0.70 0.80 0.60 1.20 1.40 1.10 1.80 2.10 1.60
Gross Total Capacity kW 9.1 11.5 9.1 15.5 17.6 13.6 26.0 29.6 23.0 38.4 43.7 33.9
Net Total Capacity kW 8.7 10.4 8.1 14.8 17.6 13.6 24.9 29.6 23.0 36.7 43.7 33.9
SHR 0.96 0.90 0.89 0.95 1.00 1.00 0.96 1.00 1.00 0.96 1.00 1.00
Flow Rate m3/h 1.44 2.16 1.44 2.52 2.88 2.16 4.32 5.04 3.96 6.48 7.56 5.76
Flow Rate l/s 0.40 0.60 0.40 0.70 0.80 0.60 1.20 1.40 1.10 1.80 2.10 1.60
Power Consumption
Power Consumption (Cooling) kW 0.7 0.7 0.3 1.7 1.7 0.6 1.7 1.7 0.7 2.7 2.7 1.1
Indoor Fans kW 0.7 0.7 0.3 1.7 1.7 0.6 1.7 1.7 0.7 2.7 2.7 1.1
Other Data
Fan Quantity 1 1 1 1
Quantity 2 2 2 3
Depth mm 50 50 50 50
Connection Size
CombiCool Inlet mm 22 28 35 42
CombiCool Outlet mm 22 28 35 42
Humidifier Feed mm 15 15 15 15
Condensate Drain mm 22 22 22 22
NOTES!
Data is taken from downflow configuration and is representational of upflow arrangement.
Units are using a 3 way valve with bypass. Other options are available.
1: Units operating a 5 degrees approach (7/12), 100% water with a CombiCool coil.
2: Duty required is a % of the nominal, i.e. 100% = unit size in kW.
Conditions
Relative Humidity % 50 40 40 50 40 40 50 40 40
Air Volume m3/h 18,338 18,338 12,837 23,745 23,745 16,622 33,100 33,100 23,170
Air Volume m3/s 5.09 5.09 3.57 6.60 6.60 4.62 9.19 9.19 6.44
1
Cooling Duty
Gross Total Capacity kW 56.7 64.4 50.0 83.1 92.7 71.5 116.0 130.0 100.2
Net Total Capacity kW 52.3 59.9 48.2 78.0 87.7 69.5 108.6 122.6 97.2
SHR 0.96 1.00 1.00 0.95 1.00 1.00 0.95 1.00 1.00
3
Flow Rate m /h 9.72 11.16 8.64 14.04 15.84 12.24 19.80 22.32 17.28
Flow Rate l/s 2.70 3.10 2.40 3.90 4.40 3.40 5.50 6.20 4.80
Gross Total Capacity kW 56.7 64.4 50.0 83.1 92.7 71.5 116.0 130.0 100.2
Net Total Capacity kW 54.2 64.4 50.0 78.8 92.7 71.5 110.2 130.0 100.2
SHR 0.96 1.00 1.00 0.95 1.00 1.00 0.95 1.00 1.00
3
Flow Rate m /h 9.72 11.16 8.64 14.04 15.84 12.24 19.80 22.32 17.28
Flow Rate l/s 2.70 3.10 2.40 3.90 4.40 3.40 5.50 6.20 4.80
Power Consumption
Power Consumption (Cooling) kW 4.5 4.5 1.8 5.1 5.1 2.0 7.3 7.3 2.9
Indoor Fans kW 4.5 4.5 1.8 5.1 5.1 2.0 7.3 7.3 2.9
Other Data
Fan Quantity 2 2 3
Quantity 3 4 5
Depth mm 50 50 50
Connection Size
CombiCool Inlet mm 54 54 67
CombiCool Outlet mm 54 54 67
Humidifier Feed mm 15 15 15
Condensate Drain mm 22 22 22
NOTES!
Data is taken from downflow configuration and is representational of upflow arrangement.
Units are using a 3 way valve with bypass. Other options are available.
1: Units operating a 5 degrees approach (7/12), 100% water with a CombiCool coil.
2: Duty required is a % of the nominal, i.e. 100% = unit size in kW.
2
Type EC Max EC AC EC Max EC AC EC Max EC AC EC Max EC AC
Conditions
Heat of Rejection 1 kW –4 6.8 6.8 15.2 11.3 11.3 23.1 16.8 16.8 27.3 22.8 22.8
3
Airflow m /h – 2,590 2,590 7,100 4,104 4,104 10,900 6,840 6,840 12,000 8,208 8,208
Airflow m3/s – 0.72 0.72 1.97 1.14 1.14 3.03 1.90 1.90 3.33 2.28 2.28
Fan Data
Power Consumption kW – 0.2 0.2 0.8 0.2 0.2 1.0 0.3 0.5 1.0 0.3 0.5
Misc Data
Fan Quantity 1 1 1 1
Connection Size
Weight 3 mm 35 45 50 70
NOTES!
1: Units operating with a 45°C condensing temperature in a 32 °C ambient temperatures.
2: "EC Max" represents EC fan configuration at Maximum airflow. "EC" data is at the same airflow as "AC" for direct
comparision.
3: For EC fans only. AC fans may vary.
4: Data currently unavailable.
AC Fans only available in certain regions to to ErP legislation. Please contact your region's sales office for further
details.
2
Type EC Max EC AC EC Max EC AC EC Max EC AC EC Max EC AC
Conditions
Heat of Rejection 1 kW 31.1 24.5 24.5 52.3 44.1 44.1 77.4 58.3 58.3 112.9 86.7 86.7
3
Airflow m /h 12,400 8,748 8,748 23,900 15,840 15,840 34,900 22,356 22,356 47,800 31,680 31,680
Airflow m3/s 3.44 2.43 2.43 6.64 4.40 4.40 9.69 6.21 6.21 13.28 8.80 8.80
Fan Data
Power Consumption kW 0.9 0.3 0.5 1.9 0.6 1.0 3.0 0.9 1.6 3.8 1.2 2.1
Speed 1/min 1.198 844 – 1.197 802 – 1.199 784 – 1.197 802 –
Misc Data
Fan Quantity 1 2 3 4
Connection Size
NOTES!
1: Units operating with a 45°C condensing temperature in a 32 °C ambient temperatures.
2: "EC Max" represents EC fan configuration at Maximum airflow. "EC" data is at the same airflow as "AC" for direct
comparision.
3: For EC fans only. AC fans may vary.
4: "Data currently unavailable.
AC Fans only available in certain regions to to ErP legislation. Please contact your region's sales office for further
details.
Substructures
Plinth
If an upflow unit is required for a room without a raised floor, a plinth should be used to
allow space underneath the unit, so that refrigerant and drain connections can be
made through the side of the plinth.
The standard plinth is 200 mm tall and made of the same frame and panel construction
as the close control unit, therefore give a natural looking height extension.
The panels are fixed to the unit using the same screw (crosshead) as the unit panel so
only one tool is required to remove all panels.
Base stand
For units to be used with a raised floor (upflow and downflow), a base stand should be
used underneath the close control unit.
The base stand comes complete with adjustable feet (+/- 25 mm available). The sur-
face between the base stand and the close control unit is lined with a 3mm semi-hard
gasket.
The height of the base stand frame can be from a minimum of 300 mm tall.
Other versions of the base stand design are available on special request: such as
sheeted and lined sides, scoops and grilles.
Protection Grille
This is the standard grille that is placed directly on top of a close control unit to protect
individuals from gaining access to the rotating fan blades during operation.
There are two variations depending on the unit's airflow direction:
Upflow: Top Air Discharge Protection Grille
Downflow: Top Air Inlet Protection Grille
Condensate Pump
In situations where it is not possible to use gravity operated drains, a condensate pump
is available to remove water collected by the condensate tray underneath the cooling
coil.
For any given unit there are two types of condensate pumps: 'Hot Water' for close con-
trol units that have humidifiers and 'Cold Water' for those without humidifiers.
Special Colours
The Multi-DENCO range is able to accommodate a variety of different panel colours,
including accessories.
For standard configuration, the frame is black and the panels are white. Colour
swatches can be provided upon request. Please contact your regional sales office for
details.
For special paint finish please provide a BS number, RAL-number or similar, if availa-
ble otherwise please provide swatches of panel requirements.
Filters
The CCU comes with standard EU4 filters (G4) to protect the coil against dust and dirt.
As an option, fine dust filters of EU7 grade (F7) filters are an alternative available with
all units.
Service Connections
Three Schrader connection points that utilise capillaries to each line, enabling use of
testing points without the removal of commissioning plates.
Interfaces
C5-12 controllers have inbuilt Modbus (RS485) connectivity.
Additional interfaces are able to be installed into the controller.
Protocols availble are as follows:
– BACnet SNMP Webpage Interface
– BACnet MS/TP Interface
– LonWorks Interface
– Trend BMS Interface is available as a separate accessory.
Water Detection
5 m long water sensing tapes can be installed below the unit to monitor any leaks or
excessive condensation, along with a sensor that detects when too much water is wit-
hin the tray.
Options for spot sensors (of varying numbers) are available to allow for a different
sample of water detection.
Energy Monitoring
Power meter with current transformer for each phase with the controller monitoring
voltage, current, power and total unit power consumption.
Values taken by this module are also viewable through the touchscreen display to give
live readings.
Values from the energy monitoring option are accessible via a BMS system.
Smoke Detection
A sensor to detect smoke particles in the airflow through the unit.
Upon detection an alarm can be generated to shut down the unit and close the
Air Damper (if fitted/required).
Pipework Connections
Several pipework connections are available for chilled water units (C-Version and
CombiCool):
1 Solder Connection
2 British Standard Pipe (BSP) Male Connections
1 2 3 3 Flange connections (PN06 and PN16)
Filter Gauge
Differential pressure gauge mounted within the front door connected via flexible hoses
to measuring points across the filter.
Remote Display
The 4.3" touchscreen display can be mounted remotely up to 50m away from the
close control unit.
60 Hz Power Supply
60 Hz power supply is now available for all sizes Multi-DENCO when used with EC
fans on the outdoor unit.
Components within Multi-DENCO units are dual rated for 50 Hz and 60 Hz allowing for
a standard configuration for both situations.
Fans
Multi-DENCO outdoor units are available with AC* or EC fans.
These are like for like replacements between them therefore they do not affect the
overall dimensions of the condensers.
* AC fans only available for a limited time for countries within the EU due to EU Regulation (ErP).
Other countries outside the EU may have continued availability.
Special Colours
Special colours for outdoor units upon request.
Please provide samples or colour standard reference to enable accurate supply.
Example Example
front view side view Size 010 Size 018 Side view
Height
Length Depth
Centre of Gravity dimensions are approximations. CombiCool and other options may vary the data given below.
For more informations please see specific customer drawings.
A-Version
Size Weight [kg] Centre of Gravity [mm]
X Y Z
010 170 280 275 830
018 180 410 265 895
030 256 600 340 885
045 362 870 340 845
065 462 1,450* 350 800
092 583 1,435 430 900
130 785 2,000 440 885
Tab. 1
* Upflow Version = 950 mm
C-Version
Size Weight [kg] Centre of Gravity [mm]
X Y Z
010 143 310 285 1,010
018 156 380 290 995
030 237 590 365 975
045 310 850 375 975
065 413 1,450* 370 890
092 512 1,175 405 1,000
130 674 1,570 435 1,010
Tab. 2
* Upflow Version = 950 mm
Detail A
Height
Depth
Airflow configuration
Panel
Box Frame
Box Frame
Panel
Legend
Electronic Expansion
TS Temperature Sensor
Valve
Ball Valve
Double Regulating Valve
(Shut Off Valve)
Fan Drain
3 Way Valve
A-Version
Outdoor Unit
Indoor Unit
NOTES!
1: Second condenser dependent upon unit selection.
2: Fan Pressure Switch may vary depending on outdoor unit configuration.
3: Not all options are displayed on this schematic. For more details please review type code.
C-Version
Indoor Unit
NOTES!
1: Various valve options available (3 way, 2 way, 2 way PICV). Schematic representative of 3 way valve
with double regulating valve.
2: Double regulating valve optional.
3: Not all options are displayed on this schematic. For more details please review type code.
A-Version + CombiCool
Indoor Unit
NOTES!
1: Various valve options available (3 way, 2 way, 2 way PICV). Schematic representative of 3 way valve
with double regulating valve in the CombiCool circuit.
2: Secondary condensers available for certain sizes.
3: Double regulating valve optional.
4: Not all options are displayed on this schematic. For more details please review type code.
5: C-Version + CombiCool units have the same schematics as the right hand circuit above, for both
circuits.
A-Version units are cooled using refrigerant. C-Version units are cooled using water or water/glycol
Main components: mixture.
– Compressors Main components:
– Evaporating Coil – Chilled Water Cooling Coil
– Electronic Expansion Valve – Valve (3 Way or 2 way)
A-Version units are used with outdoor condenser. A variety of valves, actuators and other options are
available and C-Version units are used with chillers.
A-Version + CombiCool units are a combination of both C-Version + CombiCool units are a duplication of 2 C-
the A-Version unit and the C-Version unit. Version circuits within 1 unit.
Red highlights the A-Version circuit of the unit, whereas The blue and red show independent circuits and they in
blue highlights the CombiCool circuit. turn would be connected to separate chillers/free-cooling
equipment. Each circuit uses 3 rows of the coil. Both cir-
There is only 1 coil used, but 3 rows are used for the refri-
cuits are shown with 3-Way valves and double regulating
gerant circuit and the other 3 rows are used for the chilled
valves in the bypass.
water cooling.
The refrigerant circuit would need to be connected to a
condenser and the chilled water circuit to a chiller or free-
cooling equipment.
Control Line 6
only applicable
for outdoor units
with EC fans.
Oil trap required
5 m max.
Q12 or Q13 Control Line
Power Line
Liquid Line 4
DIAGRAM NOTES!
1: Oil trap and 1% slope are required for every vertical and horizontal section respectively.
2: Outdoor unit must no more than 10 m lower than the base of the indoor unit.
3: "Power in" demonstrates a single feed. Dual power supply option available.
4: Liquid line and Discharge Line pipe sizing dependent on multiple factors and vary from unit
to unit.
5: Indoor unit able to power outdoor unit with EC fans. Indoor unit must power outdoor unit
with AC fans. Specification of cable size/quality is responsibility of installing contractor/site
engineer, but must be relative to condenser's current consumption and cable length from
indoor unit. Q12 and Q13 demonstrate separate power supplies available for twin
condensers. Mandatory for certain configurations.
6: FläktGroup Ltd recommend any 2 core screened data cable for control wiring, for example:
a. Beldon 8761
b. Alpha 2401C
c. BICC H8082
GENERAL NOTES!
i. Terminals for power line between indoor and outdoor vary. Please refer to wiring diagram.
ii. Twin condenser option is available (not shown in diagram).
NOTES!
Only pipe sizes with data entered are allowable. It is mandatory that these sizes are
used only, for both horizontal and vertical risers.
It is recommended that an optimum pressure drop in the discharge line should be
1.0K and that the pipe size should not be used if this value exceeds 2.5 K.
Final responsibility for pipe sizing is of the contractor or installer and it is recommen-
ded that separate calculations are made by a suitable qualified engineer.
Data shown below is of a A-Version unit, using inverter compressors, operating at
nominal capcity (i.e. size 010 = 10 kW). Data calculated using a 45 °C condensing
temperature.
Imperial Measurements
Metric Measurements
Unit Network / Remote Display / Unit Display Air intake sensor Air discharge sensor
C5-12 TERMINALS
Serial Card
Interface Card
(Optional)
Terminals Notes
5–6 Remote On/Off for activating and deactivating the unit via a normally open volt free contact by others.
3–5 Emergency Off, a volt free contact (supplied by others) opening, deactivates the unit (e.g. used in a fire alarm system)
10 – 11 The unit's critical alarm indication e.g. HP/LP, Airflow, High Temperature.
12 – 13 The unit's maintenance alarm indication e.g. Dirty Filter, humidifier.
5 – 17 Alarm contact of condensate pump (optional accessory)
100 – 101 Indication of unit’s operation (i.e. fans enabled)
+VDC – GND – U1 – U2 Air intake sensor
+VDC – GND – U3 – U8 Air discharge sensor (optional, only if the item is fitted).
Serial Card Interface cards for building management (optional).
Rx-/Tx- - Rx+/Tx+ - GND Unit’s network terminals for connecting multiple units. Displays already connected to these terminals.
-------- Cabling provided by others.
# Volt free contacts (voltage or signal to be provided by others).
* On-site volt free contacts must be provided (if function is required remove jumper).
NOTE!
Above details are only accurate for C5-12 controller, other controllers/interface combination may vary. In all
instances, please consult the electrical drawing for specific details. FläktGroup reserve the right to make
design modifications/updates/amendments and improvements without prior notice.
SAFE ISOLATION!
External electric circuits of Multi-DENCO must be safely isolated from active (live) components of other
non-SELV or non-PELV electric circuits through using a double or reinforced insulation!
In particular, safe isolation is required between switch contacts of external devices such as relays, contac-
tors; auxiliary switches (e.g. remote On/Off contact etc.) and their electric circuits, if these are non-SELV
and non-PELV circuits.
FläktGroup is the European market leader for smart and energy efficient Indoor Air
and Critical Air solutions to support every application area. We offer our customers
innovative technologies, high quality and outstanding performance supported by more
than a century of accumulated industry experience. The widest product range in the
market, and strong market presence in 65 countries worldwide, guarantee that we
are always by your side, ready to deliver Excellence in Solutions.