Page 16 RZR100MYM
Outdoor unit
OUTDOOR UNIT
2 3
Cassette Air Conditioner with 360° Compact Body for Quick & Easy Drain Pump is Equipped as
Installation in Tight Ceiling Standard Accessory with 850 mm
Uniform Airflow sets The Standard
(50LU-71LU) Lift.
256 mm *1 266 mm *2
850 mm
175 mm
*1 298 mm high with 100–140 KA/LU
*2 308 mm high with 100–140 KA/LU
Space. COP
Indoor Colour Decoration panel
W/W 4.85 4.29 3.78 3.79
Fresh white
3.35 3.60 2.90 2.49
unit Airflow rate (H/M/L) m3/min 21/-/13.5 32/26/20 33/28/22.5 32/26/20 33/28/22.5
Because air flows out from corner outlets, comfort Sound level (HH/H/M/L)3 dB(A) (-/35/-/28) (43/37.5/-/32) (44/39/-/34) (-/43/37.5/32 (-/44/39/34) (-/44/40/36)
spreads more widely. Dimensions
(HXWXD)
Unit mm 256X840X840 298X840X840
Decoration panel mm 50X950X950
Machine Unit kg 21 24
weight
Typical flow patterns Decoration panel kg 5.5
Certified Operation range Cooling °CWB 14 to 25
Outdoor Colour Ivory white
There are a total of 23 flow patterns. unit Compressor Type Hermetically sealed swing type Hermetically sealed swing type
Motor output kW 1.12 1.35 1.76 2.03 2.03 1.92 1.92
L-shaped Opposite Refrigerant charge (R-410A) 1.6 1.9 1.9 1.9
All-round flow 3-way flow 2-way flow 2-way flow kg (Charged for 30 m) (Charged for 30 m) (Charged for 30 m) (Charged for 30 m)
Sound level3 Cooling dB(A) 48 49 52 49 52 54
Night quiet mode dB(A) 44 45 45
Dimensions (HXWXD) mm 595X845X300 990X940X320 990X940X320
Machine weight kg 43 65 73
(E.g., installed in (E.g., installed (E.g., installed in (E.g., installed in Certified Operation range Cooling °CDB 21 to 46
Quiet Operation at 28** dB(A)
middle of ceiling) near a wall) a corner) a long room)
Piping Liquid (Flare) mm o/ 9.5
4-way flow also possible. connections Gas (Flare) mm o/ 15.9
**Selected models only Note: Whatever the discharge direction, the same type of panel is used. If installing for other than all-round flow,
Drain Indoor unit mm VP25 (I.D o/ 25XO.D o/ 32)
Outdoor unit mm o/ 26.0 (Hole)
Note : Anechoic chamber conversion value, measured according to JIS an air discharge outlet sealing material (option) must be used to close each unused outlet. Operation sound
Max. interunit piping length m 50 (Equivalent length 70)
parameters and criteria. During operation these values are some what increases when using 2-way or 3-way flow.
Max. installation level difference m 30
higher owing to ambient conditions.
Heat insulation Both liquid and gas piping
10 11
Flexibility SPECIFICATIONS
With a height of only 245 mm, installation is possible 50 60 71 100 125
even in buildings with narrow ceiling spaces Model Indoor unit FBQ50EVE FBQ60EVE FBQ71EVE FBQ100EVE FBQ125EVE
Name RZR50LVVM RZR60LVVM RZR71LVVMG RZR100MVMG RZR125MVMG
Outdoor unit
DC Fan motor and DC drain pump are utilised to Outdoor Sound pressure
level4
Cooling dB(A) 49 52 54
unit Night quiet mode dB(A) 45
improve energy efficiency Dimensions (HXWXD) mm 990X940X320
Machine weight (outdoor) kg 73
Piping Liquid mm o/ 9.5 (Flare)
connection Gas mm o/ 15.9 (Flare)
Clean
Indoor unit mm VP25 (I.Do/ 25×O.Do/ 32)
Drain
Outdoor unit mm o/ 26 (Hole)
Max interunit piping length m 50 (Equivalent length 70m)
Silver ion anti-bacterial drain pan Heat insulation Both liquid and gas piping
Position of drain pan inspection opening has Using a DC fan motor, the external static pressure
been modified for easier inspection work OPTIONS
can be controlled to within a range of 50 Pa to 150 Pa Kit name
Name of option Remark
Drain pan maintenance check window FBQ50EVE FBQ60EVE FBQ71EVE FBQ100EVE FBQ125EVE FBQ140EVE
Adjustable external static pressure Remote controller Wireless type Cooling only BRC4C66
This makes it possible to inspect for drain pan dirt and to Wired type1 BRC1C61
confirm drainage during installation without the use of Navigation Remote Controller1 BRC1E62
Adaptor for wiring KRP1C64
tools.
50 Pa 150 Pa Wiring adaptor for electrical appendices(2)
Remote sensor
KRP4AA51
KRCS01-4B
Mounting plate for adaptor PCB.2,3,4 KRP4A98
Inspection opening for Central remote controller5 DCS302CA61
drain pan Unified ON/OFF controller5 DCS301BA61
Set to low static Set to high static pressure for
pressure when ducts advanced needs such as when Schedule timer5 DST301BA61
Drain pan maintenance
are short. using dampers and long ducts. intelligent Touch Controller5 DCS601C51
check window
1
Note: Wiring for wired remote controller to be procured locally. 4
Only one mounting plate can be installed for each indoor unit.
2 5
Mounting plate is necessary for each adaptor marked . The indoor unit is equipped standardly with the interface adaptor for SkyAir series.
Comfort airflow is achieved in accordance with conditions such as 3
Up to 2 adaptors can be fixed for each mounting plate. The Interface adaptor for SkyAir series is not necessary for this indoor unit since it is equipped as standard.
Easy maintenance because the drain pan can be duct length.
removed
12 13
Benefits of DA series
COP W/W 3.60 3.56
Colour White
Indoor
Airflow rate (H/L) m3/min 17/-/14
unit
Sound level (H/L)2 dB(A) 39/-/35
Dimensions (HXWXD) mm 195X1,160X680
The technology of the DC fan motor, wide sirocco fan, Machine weight kg 27
and large heat exchanger combine for greater airflow Certified operation range °CWB 14 to 25
and quiet operation. Outdoor
Colour Ivory white
unit Compressor Type Hermetically sealed swing type
High/Middle/Low : 46/42/38 dB(A) Motor output kW 1.12 1.35
Refrigerant charge (R-410A) kg 1.6 (Charged for 30 m)
Sophisticated design Sound level3 Cooling dB(A) 48
Night quiet mode dB(A) 44
Flap neatly closes when Dimensions (HXWXD) mm 595X845X300
not in use. Machine weight kg 43
Certified operation range °CDB 10 to 46
Fresh white colour. Piping Liquid (Flare) mm o/ 9.5
connections Gas (Flare) mm o/ 15.9
Drain Indoor unit mm VP20 (I.D o/ 20XO.D o/ 26)
Installable on ceilings 4.3 m high Outdoor unit mm o/ 26.0 (Hole)
Max. interunit piping length m 50 (Equivalent length 70)
Max. installation level difference m 30
Heat insulation Both liquid and gas piping
Easy Maintenance
Outdoor unit mm o/ 26.0 (Hole)
Max. interunit piping length m 50 (Equivalent length 70)
Max. installation level difference m 30
Long-life filter (standard) requires no maintenance for Heat insulation Both liquid and gas piping
Quiet Operation at 32** dB(A) about 1 year* Note :
1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
**Selected models only 2
The filter is washable and reused after 1 year. Capacities are net, including a deduction for cooling for indoor fan motor heat.
3
Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
3
* For dust concentration of 0.15 mg/m
Uses quiet stream fan and other quiet Two time settings (2500 hrs and 1250 hrs) are available to match the installation
technologies.
environment. Maintenance time warning is displayed on the remote controller OPTIONS
(filter sign).
(FHQ50-125BV) Kit name
Easy-clean, flat surfaces Name of option Remark
FHQ50/60BVV1G FHQ100BVV1B FHQ125BVV1B FHQ100/125/140DAVMA
Replacement long-life filter Resin net KAF501DA80 KAF501DA112 KAF501DA160 KAFP501A160
Drain pump kit KDU50N125VE KDU50P140VE
Turbulent flow
is reduced
Straightening plate Quiet stream fan Drain pump kit can be easily Remote controller Wireless type
Wired type1
Cooling only BRC7EA66
BRC1C61
BRC7GA56
incorporated
Navigation Remote Controller Wired type1 BRC1E62
Wiring adaptor for electrical appendices2 KRP4AA52
Oil-resistant plastic is used for the air suction grille. a silver ion antibacterial agent mm
Note: 1Wiring for wired remote controller to be procured locally.
2
Installation box for adaptor PCB (KRP1D93A) is necessary.
This satisfies durability in restaurants and other similar that assists in preventing the
environments. growth of slime, bacteria and Drain pump kit
Note: Intended for use in salons, dining rooms, and ordinary sales floors, this specification mould that cause smells and (built inside
is not suitable for kitchens or other harsh environments. main unit)
clogging.
14 15
Comfortable
Machine weight kg 17
Certified Operation range °CWB 14 to 25
Colour Ivory white
Outdoor
• Auto swing unit Compressor Type Hermetically sealed swing type
Motor output kW 1.92
Refrigerant charge (R-410A) kg 1.9 (Charged for 30 m)
Wide-angle louvers Sound level3 Cooling dB(A) 49
Night quiet mode dB(A) 45
(by hand) Dimensions (HXWXD) mm 900X940X320
Soft material louver Machine weight kg 73
Certified Operation range °CDB 21 to 46
bends airflow over mm o/ 9.5
Piping Liquid (Flare)
a wider area connections Gas (Flare) mm o/ 15.9
Drain Indoor unit mm VP13 (I.D o/ 13 X O.D o/ 18)
Outdoor unit mm o/ 26.0 (Hole)
Max. interunit piping length m 50 (Equivalent length 70m)
Auto-swing 5-level air direction setting Max. installation level difference m 30
Heat insulation Both liquid and gas piping
Note :
1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
2
Capacities are net, including a deduction for cooling for indoor fan motor heat.
3
Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
Gettable to 5
different levels
OPTIONS
Kit name
Name of option Remark
FAQ100CVEA
Drain-up kit K-KDU572EVE
Remote controller Wireless type Cooling only BRC7EB519
Wired type1 BRC1C61
Navigation Remote Controller Wired type1 BRC1E62
• Switchable fan speed : High / Middle / Low Wiring adaptor for electrical appendices KRP4AA51
Installation box for adaptor PCB KRP4AA93
Compact & Sophisticated Design • Auto airflow rate (When BRC1E62 is used) Note: 1Wiring for wired remote controller to be procured locally.
1,200mm
Depth 200mm 240mm Drain Pump Kit is Available as
Weight 26kg 17kg Option.
Installs onto side of unit.
Indoor unit
Drain pump kit
16 17
overview
overview NEW NEW FHQ50/60BVV1G NEW
Cooling only Indoor unit FCQ50-71LUV1 FCQ100-140KAVEA FBQ50-140EVE FHQ100-140DAVMA FAQ100CVEA
RZR50-60LVVM RZR50-60LVVM,RZR71LVVMG
RZR100-125MVMG,
Outdoor unit RZR100-125MVMG, RZR50-60LVVM RZR100-140MYM RZR100MYM
RZR71LVVMG RZR100-140MYM RZR100-140MYM
Auto swing
Swing pattern selection
Independent up-and-down airflow
DC fan motor (Indoor unit)
Switchable fan speed 2step 3step 3step 2step 3step for DA 3step
Auto airflow rate*1
Comfort
High fan speed mode
Program “Dry”
High ceiling application *6 *6
Two selectable temperature-sensors *2
Year-round cooling applicable
Night quiet operation *3
Auto-restart
Control by 2 remote controllers
Group control by 1 remote controller
Control External command control *8 *8 *8 *8 *8 *8
features *8 BV series
Central remote control needs option
Interlock control with Heat Reclaim Ventilator
DIII-NET communication standard Only for DA series
High-efficiency filter
Options Ultra long-life filter
Fresh air intake kit Only for DA series
Note: *1 : Applicable when BRC1E62 is used *3 : For outdoor units *5 : Applicable for FVQ50-100 *7 : Installable on max. 4.3 m high ceiling *9 : Applicable for 60/71 class indoor unit
*2 : Applicable when wired remote controller is used *4 : Applicable when BRC1C61 is used *6 : Installable on max. 3.5 m (50-71) *8 : Option *10 : Applicable for RZR50-71M, RZR-LV and RZR-LU
and 4.3 cm.(100-140 ) high ceiling
18 19
Remote Controller Note: It is not possible to use two wireless remote controllers.
Interlock control
Enables interlocking control with external equipment such as
Setpoint auto reset Off timer (programmed) Group control by 1 remote controller Heat Reclaim Ventilator.
Even if the set temperature is changed, it returns to the preset Sets and saves setting for an increment of time that You can turn up to 16 indoor units on/off with a single remote
temperature after a preset period of time. automatically turns off air conditioner after a preset period of controller. (When using connected indoor units, the settings DIII-NET communication standard
time for each time operation starts. must all be the same and on/off will be simultaneous.) Standardly equipped interface enables connection to
Setpoint range set centralised control system without need of an adaptor.
Saves energy by limiting the minimum and maximum set On/Off timer
Options
temperatures. Avoids excessive heating and cooling.
Operation starts when the preset time of the ON timer elapses
and stops when the preset time of the OFF timer elapses.
Weekly schedule timer
High-efficiency filter unit Fresh-air intake kit
Up to five operation ON/OFF settings can be programmed per
day for each day of the week. Not only can the time be set for Two types are available: 65% and 90% colorimetry. You can provide air-conditioning with fresh air from outside.
the operation ON setting, but also the temperature. Convenient for places where a ventilation fan cannot be
installed.
Ultra long-life filter
Note: *Connecting ducts, insect nets, fire dampers, air filters, and other parts should, as required,
Requires no maintenance for about 4 years* (10,000h) in be procured locally.
**Outside Air fan interlocked with air conditioning unit is necessary. Optional PCB(KRP1C63)is
20 21
Wireless remote
Energy saving controller
Restaurant opened Full tables at lunchtime After 30 minutes* Central remote controller Unified on/off controller Schedule timer
Temperature is set to 27ºC Then is lowered to 24ºC for Automatically returns to preset
crowded room temperature (27ºC) DCS302CA61 (Option) DCS301BA61 (Option) DST301BA61 (Option)
Returns to DCS601C51 (Option)
22 23
Specifications, designs and other content appearing in this brochure are current as of December 2018 but subject to change without notice.
c All rights reserved 12/18 SS