The PCS-996R is a multifunctional disturbance and fault recorder designed for substations. It can record data through centralized or distributed system architectures based on customer needs. The recorder captures measurement curves from 48 analog and 60 binary channels in a single unit. It initiates recording based on voltage, current, and frequency thresholds or binary inputs. Recorded data is extracted for efficient analysis and synchronized via external time source. The robust hardware and advanced operating system enable high-speed, high-precision real-time data processing and communications via IEC protocols.

Uploaded by

Abdul Ahad
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
109 views2 pages

Xpy 1 G

The PCS-996R is a multifunctional disturbance and fault recorder designed for substations. It can record data through centralized or distributed system architectures based on customer needs. The recorder captures measurement curves from 48 analog and 60 binary channels in a single unit. It initiates recording based on voltage, current, and frequency thresholds or binary inputs. Recorded data is extracted for efficient analysis and synchronized via external time source. The robust hardware and advanced operating system enable high-speed, high-precision real-time data processing and communications via IEC protocols.

Uploaded by

Abdul Ahad
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

www.nrec.

com/en

PCS-996R
Disturbance Fault Recorder

The PCS-996R disturbance & fault recorder (DFR) is a


multifunctional data acquisition system designed to address
Functions
the data recording requirements of substations. It captures the Recording Functions
curves of monitored quantities and aligns the values of different • Initiating recording by AC voltage
supervised objects to build disturbance records. The PCS-996R - Phase voltage over upper limit
helps users simplify disturbance analysis by combining the discrete - Phase voltage under lower limit
records in different protective relays. - Sudden increase/decrease of phase voltage over limit
- Negative sequence voltage over upper limit
The disturbance & fault recording system architecture can be
- Zero sequence voltage over upper limit
centralized or distributed based upon customers’ requests.DFRs
can also be applied to a substation independently with a local - Sudden change of zero-sequence over limit
computer and HMI software. The protocol for the communication - Frequency over upper limit
network can be IEC 61850, FTP and IEC 60870- 5-103 based on
- Frequency under lower limit
LAN. GOOSE function is integrated to receive information from the
- Absolute value of df/dt over limit
process bus.
• Initiating recording based on AC current out-of-limit
Standard format - Phase current over upper limit

Disturbance Fault
PCS-996R DFRs are equipped with 48 analog channels and 60 - Sudden change of phase current over limit
binary channels in one unit. Furthermore, it can be synchronized - Negative sequence over upper limit Recording
via an external time source.
- Zero sequence over upper limit

Recording - Sudden change of zero sequence over limit


- Power swing
• Triggered recording @ 9600Hz, for short-term transient
process. • Initiating recording based on binary input

• Continuous recording @1200Hz, for mid-term dynamic • Continuous recording (24hours of uninterrupted recording)
process

• Slow recording @1 ~ 50Hz , for long-term power quality


monitoring

• Extract recording @ 9600Hz, isolate fault channels


DXWRPDWLFDOO\IRULQIRUPDWLRQHI¿FLHQF\

153
Protection Automation Control

DFR Manager System


500kV Disturbance & Fault Recorder
GPS
@ 220kV Disturbance & Fault Recorder
Email
110kV Disturbance & Fault Recorder
Server 1 Server 2 Local DFR Analysis Workstation

Front end Front end


Communication Communication
Server 1 Server 2
Station A Station B
Station A

WAN/LAN
Station E Station D Station C

Station G Station F

Station I Station H

Station J
Station K
Station L Station M Station N Station O

Station R
Station Q
Station P

Station S Station T Station U Station V

Figure 1 Typical application of the PCS-996R in a wide-area DFR system

Auxiliary Function Features


• Self diagnostic test
• The robust hardware platform adopted for DFR is the same
• Loss of DC power supply alarm as NR Electric’s protection and control system, which has
EHHQZHOOSURYHQLQ¿HOG
• Hardware circuit online detection
• This device adopts a fully-closed chassis with a well
• Support IRIG-B time synchronization
designed structure, providing separate spaces for low and
high voltage systems. The traditionally integrated circuit
Communications board mode is abandoned. Furthermore, anti-interference
• 1 RJ45 Ethernet port complies with IEC60870-5-103 and measures are integrated into the software, thus enhancing
IEC61850 protocol anti-interference capabilities.

• 1 RS-485 serial port used for GPS time synchronization • This device makes use of an advanced hardware platform,
which includes 16 bits parallel A/D converter, 320*240
• 56VHULDOSRUWXVHGWRWHVWDQGFRQ¿JXUHGHYLFH
graphic dot matrix LCD, and real-time multi-task operating
system. The advanced hardware platform can achieve the
• 1 Ethernet interface used for FTP service for continuous
high-capacity, high-precision, high-speed, and real-time data
recording and real-time waveform display
processing. The high-precision parallel A/D converter can
• 7ZR¿EHU(WKHUQHWSRUWVZKLFKVXSSRUW,(&DQG sample all the AC signals simultaneously in order to ensure
IEC61850 protocol (available for PCS-996R) the accuracy of these measurements.