StarView User Guide
StarView User Guide
Introduction
StarView is software provided free of charge by Star Cool and can be downloaded from the Star Cool
website at www.starcool.dk
The software can be used for retrieving data logs and for monitoring the state of the unit online.
Settings
When the ".exe"- file has been downloaded it can be saved to any known folder - E.g. C:\Program
files\StarView. Installation is not necessary. The file can be executed by double clicking on the file
icon. Two sub directories will be created: "/PCLog" and "/Retrieve" when running the program for
the first time. When selecting “Print and save window” in Help menu a third folder named “/Bitmaps”
will be created.
The default communication port is Com port 1. This is normally the Com port number of the serial
port on the laptop, but since newer laptops aren’t equipped with a serial port a "USB to serial port" –
adapter is needed. This adapter will usually obtain a Com port number different from Com port 1.
There are two ways to make StarView work with a "USB to serial port" – adapter.
One way is to change the port number of the adapter (refer to the user manual of the adapter
and/or Help file for Windows) or second way is as follows:
- Create a short cut to the "starview.exe" – file and e.g. place it on the desk top
- Right click on the short cut and choose "Properties"
- Find "Destination" E.g.: “C:\Program files\starview\StarView.exe”
- Add a space and "port=x" after the text written in the "Destination" field. X is the desired
port number. E.g.: “C:\Program files\starview\StarView.exe” port=5
- Click "Ok"
- Test the setting by double clicking the short cut icon.
Connection
Connect to the Star Cool unit
In order to establish a connection between the Star Cool unit and the laptop a retriever cable is
needed. The unit end must have a 5 pin connector and the pc end must have a 9 pole SUB D
connector. Newer laptops are not equipped with a serial port. If this is the case a "USB to serial
port"- adapter must be used.
Please refer to the user manual for
the installation of the adapter and the
previous section for the settings in
StarView.
________________________________________________________________________________________________________________________
Bjerndrupvej 47 • 6360 Tinglev, Denmark • Phone: +45 7364 3400 • Fax: +45 7364 3569
CVR/SE no.: 13 82 37 74 • [email protected] • www.starcool.dk
Menu functions
File
Exit
Closes the program.
Unit
System View
Page 2 of 11
Alarm list
This shows a list of active and inactive unit
alarms/warnings.
The user can clear only the inactive alarms/warnings.
Tool
PCLog
Provides the option of creating a log file with the laptop
connected to the Star Cool unit. A good option for trouble
shooting purpose.
The log interval can be set from 10 seconds and upwards.
Page 3 of 11
Retrieve data log
Download the controller data log file to the PC.
First step is to choose how much data that will be
downloaded. In most cases it is a good idea to choose "All
data".
Page 4 of 11
The data from the file can now be viewed. Click on "Show report"
Par 1 – 5 refers to parameters for each alarm/warning and event. These parameters can be found in
the operating and service manual in conjunction with the current alarm/warning number.
The columns that follow Par 5 all display a value or a status of a component in the system at the
time of the logging. Refer to "Legend" in operation and service manual for the definition of the
abbreviation used.
Page 5 of 11
By default all information is shown in
the report, but if less information is
required on a printout, this can be
adjusted in "Report setup".
E.g. if you only want warnings/alarms
to be shown, you can uncheck all but
the alarm check box or if you want to
make a report of the temperatures
only, you need to uncheck "Alarm"
and "Extended data 1 & 2".
Page 6 of 11
PTI test
Execute and monitor Pre Trip Inspection test.
The Fail/Pass result of each sub test step is shown in the
list.
Setup
Container ID
Page 7 of 11
Sensor calibration
USDA and Cargo temperature probe offset adjustment.
Unit configuration
In unit configuration it is possible to customize the unit for
the specific customer.
Page 8 of 11
Software upload
Occasionally new controller software is released on the Star
Cool website. It’s always encouraged to update controller
software to the latest version.
Page 9 of 11
The controller won’t be affected by
the upload until it has been
completed.
Window
Cascade
To arrange the open program windows on top of each other.
Tile
To arrange the open program windows beside each other.
Help
Instruction
Opens a window with a simple help file.
Page 10 of 11
Print and save window
Print and save the active window as a graphics file in BMP
and JPG format.
About StarView…
Shows the software version number for PC program and for
the connected controller.
The unique controller ID string used by the data logger can
also be found here.
Further questions
Please don’t hesitate to contact the Star Cool service department: [email protected] or
+45 73643500 for any further questions relating to the StarView software.