Hydraulic Design Calculation For Hpu: Adcop - Abu Dhabi Crude Oil Pipeline Project Habshan - Fujairah
Hydraulic Design Calculation For Hpu: Adcop - Abu Dhabi Crude Oil Pipeline Project Habshan - Fujairah
Habshan - Fujairah
RASHMI ANAND
A 27-7-2015 ANAND KUMAR ISSUED FOR APPROVAL
SHARMA KUMAR
0 18-JAN-17 RASHMI S ANAND K ANAND K ISSUED FOR CONSTRUCTION
© Copyright China Petroleum Engineering &Construction (Group) Corporation 2008 All rights reserved.
“This document is issued for the execution of Abu Dhabi Crude Oil Pipeline (ADCOP) project.
Copying this report without the permission of CPECC, ILF and IPIC is not permitted.
Hydraulic Calculations
Project :HPU
Equipment : Actuator of 19.04 liter volume NOTES
Adiabatic Constant = 1.40 Adiabatic expansion calculation used
Max Pressure Barg (P3) = 200.00 2900 psi Max Sys. pressure
Min Pressure Barg (P2) = 150.00 2175 psi Min Sys. Pressure
Fluid Swept Vol required Litres (between Max & Min Press) = 19.40
Total Fluid Swept Vol Litres (between Max & Min Press) = 19.4 Calculated Value
Total fluid and gas Volume calculated litres = 126.0 Total Oil AND Gas Volume Required calculated
Minimum amount of accumulator fluid volume required litres = 40.9 Min Calculated Value of Fluid needed
Minimum amount of Nitrogen gas volume required litres = 85.0 Min Calculated Value
Total Accumulator fluid and gas Volume selected = 128.0 Standard Accumulator Size selected
Total Accumulator over or under fluid and gas Volume selected = 2.0 Should be >=0
Actual amount of fluid stored between Min and Max Pressure = 19.7 Actual Amount Stored between MinP to MaxP
Total Accumulator over or under fluid Volume selected = 0.3 Should be >=0
Total Fluid Returned to Reservoir on shutdown = 41.6 Actual Amount stored between Zero to max P
Volume used to size Reservoir
Fluid Variance to selected volume of accumulators = 0.4 Should be >=0
Actual selection
Qty Each (litres) Total (litres)
PistonAccumulator 3.0 37.8 113.4
1.0 18.9 18.93
total fluid/gas volume : 132.33