PG0 - AKO - FAILURES
FAILURE NUMBER SHORT DESCRIPTION
Gorenje, d.d.
3503 Velenje, p.p.107, SLOVENIA Telephone: +386 63 8990 / 8992 432 Telefax : +386 63 8992 794
SERVICING INSTRUCTIONS 4-022-0705
FAILURE DISPLAY All LED repeatedly pulsate: 1x ( sec. ON, sec. OFF) than 5 sec. OFF(pause) On LED F1
DESCRIPTION
F1
The failure is set, if the connection to the temperature sensor is open or if there is a short circuit between the two terminals of the sensor. The washing program will be ended without connection to temperature heating. The failure will be displayed at the end sensor open or short-circuited of the washing program. This must be check at the beginning of program and again before heating step. If after 8 sec. after start the program the door lock is not yet close (power on contact C on door lock) that this failure will be displayed. Supply of door lock will be ON, and WM will wait that door lock will be close.
F2
The connection with door lock is open
the water level was not reached. F3 - water tap closed - leak in the machine - valve defect
F4
the connection to the tacho generator is open or shortcircuited
The LED START/PAUSE repeatedly pulsate: 2 x ( sec. ON , sec. OFF) than 5 sec. OFF (pause) ----------------------------------------------------------- -----------------------------If door lock lose power on contact (check longer time), than also failure will be displayed. All LED repeatedly The washing program will be stop. To start the pulsate: washing program again, the user has to check if 2 x ( sec. ON , sec. the door close is and press the Start-button. If OFF) than 5 sec. OFF the failure occurred again, the washing program (pause) is stopped for permanently. If is water in the machine, than pumping 2 minutes Supply of On LED F2 door lock will be OFF.. Failure will be displayed again, and it is not possible to start the washing program again. The failure is set, if within filling or heating step the water level is below level 1 for the filling time or 2 minutes in heating time. If the failure occurred the first time within a washing program, the current step will be started again. All LED repeatedly If the failure occurred the second time (twice in pulsate: 3 x ( sec. ON, succession), the washing program is stopped, sec. OFF) and the failure will be displayed. To continue than 5 sec. OFF(pause) the washing program, the user has to press the Start-button. If the failure occurred the third On LED F3 time, the washing program is stopped, the failure will be displayed, and it is not possible to start the washing program again. If the washing program is active and the motor control unit gets no signal from the tacho All LED repeatedly generator, the first time the failure occurs a pulsate: 4 x ( sec. ON, pause of 1minute is executed. This repeat 3 sec. OFF) times. If once happens that motor work O.K. than 5 sec. OFF(pause) than all previous failure must be deleted. When the failure is detected the 4 times the washing On LED F4
TEHNINA PRIPRAVA SERVISNIH STORITEV
gorenje
WASHING MACHINES
Gorenje, d.d.
3503 Velenje, p.p.107, SLOVENIA Telephone: +386 63 8990 / 8992 432 Telefax : +386 63 8992 794
SERVICING INSTRUCTIONS 4-022-0412
program is stopped immediately. If the temperature is higher that 60C than cool down with cold water 30 seconds. Then pumping water 2 minutes. STOP the program. The failure will be displayed. The failure is set, if the washing program is active and the motor is working without control of triac. The washing program is stopped immediately. After 2 minutes try again. If the failure is not present, than forget the first failure and continue work. If it is the same failure again, than program stops complete. If the temperature is higher than 60C than cool down with cold water 30 seconds. Then pumping water 2 minutes. STOP the program. The failure will be displayed. The failure is set, if after a heating step the temperature is more than 15C lower than the rated temperature. The washing program will be ended normally. The failure will be displayed at the end of the washing program.
F5
the triac is short-circuited
All LED repeatedly pulsate: 5 x ( sec. ON, sec. OFF) than 5 sec. OFF(pause) On LED F5
F6
temperature not reached - heater defect
All LED repeatedly pulsate: 6 x ( sec. ON, sec. OFF) than 5 sec. OFF(pause) On LED F6
F7
the water level does not fall below level 1 - pump clogged - pump defect
The failure is set, if after a pumping step the water level did not fall below level 1. If the failure occurred the first time within a washing program, the current step will start again. If the failure occurred the second time (twice in succession), the washing program is stopped and the failure is displayed. To continue the washing program, the user has to press the Start-button. If the failure occurred the third time, the washing program is stopped and the failure is displayed. It is not possible to start the washing program again.
All LED repeatedly pulsate: 7 x ( sec. ON, sec. OFF) than 5 sec. OFF(pause) On LED F7
F8
The failure is set, if at the end of the spinning cycle of the testing program the spin is more The WM not reach max. spin than 200rpm lower than the rated speed. The speed (the tapped field relay failure is displayed after the end of the testing does not switch) program.
All LED repeatedly pulsate: 8 x ( sec. ON, sec. OFF) than 5 sec. OFF(pause) On LED F8
TEHNINA PRIPRAVA SERVISNIH STORITEV
VILI GARNBRET