0% found this document useful (0 votes)
113 views6 pages

760 Automatic Handheld Pressure Calibrator

The Additel 760 is a fully automatic, handheld pressure calibrator weighing less than 4 lbs. It has a built-in pump and precision pressure sensor to generate and measure pressure. It has switchable internal pressure modules for measurement ranges from -12.5 to 300 psig. Accuracy is 0.02% of the full scale over 1 year. It can source pressure, measure pressure, and test electrical loops. Optional features include HART communication, data logging, and external pressure modules.

Uploaded by

AngelDuque
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
113 views6 pages

760 Automatic Handheld Pressure Calibrator

The Additel 760 is a fully automatic, handheld pressure calibrator weighing less than 4 lbs. It has a built-in pump and precision pressure sensor to generate and measure pressure. It has switchable internal pressure modules for measurement ranges from -12.5 to 300 psig. Accuracy is 0.02% of the full scale over 1 year. It can source pressure, measure pressure, and test electrical loops. Optional features include HART communication, data logging, and external pressure modules.

Uploaded by

AngelDuque
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

Additel 760

Automatic Handheld Pressure Calibrators


Pressure / Process Calibration Equipment

Selection Guide
Model
760-LLP 760-LLP-DL 760-D 760-D-DL 760-MA 760-MA-DL
Features

Pressure ±30 in H2O ±30 in H2O -12.5 to 35 psi -12.5 to 35 psi -12.5 to 300 psig -12.5 to 300 psig
Range[1] (±75 mbar) (±75 mbar) (-0.86 to 2.5 bar) (-0.86 to 2.5 bar) (-0.86 to 20 bar) (-0.86 to 20 bar)

Accuracy (%FS) 0.05[1] 0.05[1] 0.02%FS[1] 0.02%FS[1] 0.02%FS[1][3] 0.02%FS[1][3]

Stability (%FS) <0.005[2] <0.005[2] <0.005[2] <0.005[2] <0.005[2] <0.005[2]

Gauge Pressure
• • • • • •
Differential Pressure
• • • •
Absolute Pressure
• •
Barometric Pressure
• •
Removable Internal
Module • • • • • •
External Pressure
Module • • • • • •
Temperature
Compensated • • • • • •
Built-in Electrical Pump
• • • • • •
Built-in Filter
• • • • • •
Built-in Liquid Trap
• • • • • •
Source/Simulate 24 mA
• • • • • •
Measure mA or V
• • • • • •
24V Loop power
• • • • • •
Pressure switch test
• • • • • •
HART Communication
• • •
Task Documentation
• • •
Data Logging
• • •
Channels 4 4 4 4 4 4

USB and Wi-Fi


• • • • • •
[1] FS specification applies to the span of the module range.
[2] Stability based on FS of the internal pressure module. Internal module is switchable.
[3] Specification based on gauge measurement. An additional 55 pa uncertainty will need to be included when measuring in absolute mode.

01 Phone: 714-998-6899 Email: [email protected] Corporate Headquarters Salt Lake City Office
Rev # 20220831 2900 Saturn Street #B 1364 West State Rd. Suite 101
Brea, CA 92821, USA Pleasant Grove, UT 84062, USA
Additel 760
Automatic Handheld Pressure Calibrators
Pressure / Process Calibration Equipment

Fully automatic calibrator with built-in pump and controller


Switchable internal pressure modules for expandable ranges
Accuracy (1 year) of 0.02%FS
External pressure modules available (measure only)
Less than 4 lbs (1.8 kg) for handheld operation
Source pressure, measure pressure and electrical
4 channels
Optional HART communications
Optional data logging and task documenting
USB and Wi-Fi communications

OVERVIEW

A portable automated pressure calibrator in the palm of your hand—this could be


our most exciting product yet! The Additel 760 series Automatic Handheld Pressure
Calibrator takes portable pressure calibration to new levels. Weighing less than 4 lbs
(1.8 kg), the ADT760’s innovative design contains a built-in pump, precision pressure
sensor, internal controller and a large touch-screen color display. To generate
pressure, simply key in the desired pressure and the Additel 760 will do the rest.
Each unit has four channels: one internal pressure channel for source and measure
pressures, two external pressure measurement channels, and one electronic measure
and source channel. This series of calibrator has three standard models with the option
of adding HART communications, documentation and data logging.

02 Phone: 714-998-6899 Email: [email protected] Corporate Headquarters Salt Lake City Office
Rev # 20220831 2900 Saturn Street #B 1364 West State Rd. Suite 101
Brea, CA 92821, USA Pleasant Grove, UT 84062, USA
FEATURES
Pressure / Process Calibration Equipment

ADT760-LLP
The 760-LLP is designed for low pressure calibration and comes with a build-in pressure module of your choice. The maximum
range module compatible with the ADT760-LLP is to ±30 inH2O (±75 mbar) and provides an accuracy to 0.05%FS (see
ordering information for configurations with the option of the ADT760 and a module of your choice). Additional internal pressure
modules (ADT155 series) are available and provide a variety of ranges down to ±0.25 inH2O (±0.62 mbar). The accuracy of
0.05%FS and control stability 0.005%FS is based on the internal module’s span. Measurements can be made in gauge or
differential mode.
ADT760-D
The 760-D gives you differential and gauge pressure but at a higher pressure range than the ADT760-LLP. Covering the
range of -12.5 to 35 psi (-0.86 to 2.5 bar) and with an accuracy of 0.02%FS, the ADT760-D is an ideal solution to cover very
common gauge and differential pressure measurements. The Additel 760-D comes with an internal module of your choice. The
maximum range module compatible with the ADT760-D is to 35 psi. Lower pressure configurations
down to ±10 inH2O differential can be purchased to improve accuracy at lower pressures.
ADT760-MA
The 760-MA generates and controls pressure from vacuum pressures up to 300 psig (20 bar.g)
with an accuracy of 0.02%FS. Equipped with a built-in barometric reference, each unit can switch
between gauge and absolute pressure types. A variety of internal sensors are available which offer
lower pressure ranges for improved performance.
Documenting Process Functionality
Each model of the Additel 760 series has an option incorporating documentation and communication
functions turning your 760 into a multifunction documenting process calibrator. This feature provides
HART communication, task documentation and data logging.

Pressure Specifications
Specification 760-LLP 760-D 760-MA
±30 inH2O -12.5 to 35 psi -12.5 to 300 psig
Max Pressure Range
(75 mbar) (-0.86 to 2.5 bar) (-0.86 to 20 bar.g)
Accuracy 0.05%FS[1] 0.02%FS[1] 0.02%FS[1][3]

Stability <0.005%FS[2] <0.005%FS[2] <0.005%FS[2]

Pressure Type Differential, Gauge Differential, Gauge Gauge, Absolute


Over Range Indication 120%
Resolution 6 digits

Pa, hPa, kPa, mPa, bar, mbar, psi, mmHg@0°C, cmHg@0°C, mHg@0°C, inHg@0°C, inH 2O@4°C, mmH 2O@4°C,
Measurement Units cmH2O@4°C, mH2O@4°C, mmH2O@20°C, cmH2O@20°C, mH2O@20°C, mH2O@68°F, inH2O@20°C, kgf/cm2, mtorr, torr, lb/
ft2, tsi, custom

Barometric Accuracy N/A N/A 55 Pa[4]


Hose, 5 ft (1.5 m), with built-in filter to Hose, 5 ft (1.5 m), with built-in filter to
Connection Barb fitting
1/4BSPF, 1/4NPTF, and M20F adapters 1/4BSPF, 1/4NPTF, and M20F adapters
Pressure Output Rate <30 Seconds (30 inH2O/100 ml) <10 Seconds (35 psi/5 ml) <90 Seconds (300 psi/5 ml)
[1] FS specification applies to the span of the module range.
[2] Stability based on FS of the internal pressure module. Stability is 0.005%FS or 0.05 pa whichever is greater. Internal module is switchable.
[3] Specification based on gauge measurement. An additional 55 pa uncertainty will need to be included when measuring in absolute mode.
[4] 55 Pa uncertainty (k=2) includes calibration uncertainty, linearity, and long-term stability (<30 Pa per year). Barometer range of 60 to 110 kPa.

Electrical Specifications
Specification Range Resolution Accuracy Note

mA Measure ± 30 mA 0.0001 mA 0.01%RD + 0.005%FS Impedance <10Ω

V Measure ± 30V 0.0001 V 0.01%RD + 0.005%FS Impedance >1 MΩ

mA Source 24 mA 0.001 mA 0.01%RD + 0.005%FS 20 mA @ 1 K

Loop Power Source 24 V N/A ±1V 50 mA (Max Loading)

Pressure Switch Open, close. Support for mechanical switches and NPN/PNP digital switches.

Temperature Compensation 41°F to 95°F (5°C to 35°C)

Temperature Coefficient < ± ( 0.001%RD + 0.001%FS ) / °C outside of 5°C to 35°C

03 Phone: 714-998-6899 Email: [email protected] Corporate Headquarters Salt Lake City Office
Rev # 20220831 2900 Saturn Street #B 1364 West State Rd. Suite 101
Brea, CA 92821, USA Pleasant Grove, UT 84062, USA
Internal Modules Specifications and Compatibility
Pressure / Process Calibration Equipment

Module Range[6]
Accuracy Burst
Module Media 760-LLP 760-D 760-MA
(%FS)[1] Pressure
inH2O mbar

DP025 ±0.25 ±0.62 G 0.2[2] 100x



DP050 ±0.5 ±1.25 G 0.1[3] 100x

DP1 ±1 ±2.5 G 0.05[4] 100x

DP2 ±2 ±5 G 0.05[4] 100x

DP5 ±5 ±10 G 0.05[4] 50x

DP10 ±10 ±25 G 0.05[4] 20x
• •
DP20 ±20 ±50 G 0.05 20x
• •
DP30 ±30 ±75 G 0.05 20x
• •
DP50 ±50 ±125 G 0.05 3x

DP100 ±100 ±250 G 0.02 3x

DP150 ±150 ±350 G 0.02 3x

DP300 ±300 ±700 G 0.02 3x

DP400 -380 to 400 -950 to 1K G 0.02 3x

DP800 -380 to 800 -950 to 2K G 0.02 3x

DP1K -380 to 1K -950 to 2.5K G 0.02 3x

Gauge
psi bar
Pressure

CP10 ±10 ±0.7 G 0.02[5] 3x


• •
CP15 -13.5 to 15 -0.95 to 1 G 0.02 [5]
3x
• •
CP30 -13.5 to 30 -0.95 to 2 G 0.02[5] 3x
• •
CP35 -13.5 to 35 -0.95 to 2.5 G 0.02[5] 3x
• •
CP50 -13.5 to 50 -0.95 to 3.5 G 0.02[5] 3x

CP100 -13.5 to 100 -0.95 to 7 G 0.02[5] 3x

CP150 -13.5 to 150 -0.95 to 10 G 0.02[5] 3x

CP200 -13.5 to 200 -0.95 to 14 G 0.02[5] 3x

CP300 -13.5 to 300 -0.95 to 20 G 0.02[5] 3x

[1] FS specification applies to the span of the module range. Accuracy includes one-year stability, except for DP025 to DP10 modules.
[2] Accuracy is a 6 months spec, 1-year long-term drift is 0.2%FS.
[3] Accuracy is a 6 months spec, 1-year long-term drift is 0.1%FS.
[4] Accuracy is a 6 months spec, 1-year long-term drift is 0.05%FS.
[5] Specification based on gauge measurement. An additional 55 pa uncertainty will need to be included when measuring in absolute mode. Applicable
only for use with the ADT760-MA
[6] The low module pressure range may be outside the pressure range of the calibrator
* ADT155 Pressure Modules are calibrated in psi & inH2O

04 Phone: 714-998-6899 Email: [email protected] Corporate Headquarters Salt Lake City Office
Rev # 20220831 2900 Saturn Street #B 1364 West State Rd. Suite 101
Brea, CA 92821, USA Pleasant Grove, UT 84062, USA
General Specifications
Pressure / Process Calibration Equipment

Specification Description Optional Internal Pressure Modules


Four total: one electrical, one internal pressure,
Channels Module Number Description
two external pressure (measure only)

Enclosure IP Rating IP52 water and dust proof Pressure module for ADT760-LLP, ±0.25 inH2O,
ADT155-20-DP025
±0.2%FS
Rechargeable Li-Ion battery, typically 10 hours of
Battery
operation, recharges in less than 4 hours ADT155-10-DP050 Pressure module for ADT760-LLP, ±0.5 inH2O, ±0.1%FS
Display Color 800 x 480 TFT 5-inch touch screen
ADT155-05-DP1 Pressure module for ADT760-LLP, ±1 inH2O, ±0.05%FS
Communications USB and WiFi

ADT155-05-DP2 Pressure module for ADT760-LLP, ±2 inH2O, ±0.05%FS


Weight <4 lbs (<1.8 kg)

Size 9.3 x 4.3 x 2.8 in (235 x 110 x 70 mm) ADT155-05-DP5 Pressure module for ADT760-LLP, ±5 inH2O, ±0.05%FS

ISO 17025 accredited certificate with data Pressure module for ADT760-LLP & -D ±10 inH2O,
Certification ADT155-05-DP10
included ±0.05%FS
HART Communications Optional (ADT760-X-DL model) Pressure module for ADT760-LLP & -D, ±20 inH2O,
ADT155-05-DP20
±0.05%FS
Optional (ADT760-X-DL model), up to 1,000,000
Data Logging
readings (date and time stamped) Pressure module for ADT760-LLP & -D, ±30 inH2O,
ADT155--05-DP30
±0.05%FS
Task Documentation Optional (ADT760-X-DL model) up to 1000 tasks
ADT155-05-DP50 Pressure module for ADT760-D, ±50 inH2O, ±0.05%FS
Automation Functions Switch test, auto step, leak test

Misuse Protection Up to 30 V on any two sockets ADT155-02-DP100 Pressure module for ADT760-D, ±100 inH2O, ±0.02%FS

English, German, French, Italian, Spanish,


Multi Lingual Interface ADT155-02-DP150 Pressure module for ADT760-D, ±150 inH2O, ±0.02%FS
Portuguese, Chinese, Japanese, and Russian

Pump Life >500,000 cycles


ADT155-02-DP300 Pressure module for ADT760-D, ±300 inH2O, ±0.02%FS
Rechargeable Li-Ion battery, external power:
Power Pressure module for ADT760-D, -380 to 400 inH2O
110/220 V power adapter 10 V ADT155-02-DP400
(-13.5 to 15 psi), ±0.02%FS
Operation: 32°F to 122°F (0°C to 50°C), 0-90%
RH, less than 3,000 meters Pressure module for ADT760-D, -380 to 800 inH2O
ADT155-02-DP800
Compensated temperature: 32°F to 122°F (0°C to (-13.5 to 30 psi), ±0.02%FS
Environment Specifications
50°C)
Pressure module for ADT760-D, -380 to 1K inH2O (-13.5
Storage temperature: -4°F to 158°F (-20°C to ADT155-02-DP1K
to 35 psi), ±0.02%FS
70°C)
Pressure module for ADT760-D & -MA, ±10 psi,
Vibration: 4 g (20 to 2,000 Hz) ADT155-02-CP10
Vibration and Shock ±0.02%FS
Shock: 8 g, 1 meter drop test
Pressure module for ADT760-D & -MA, -13.5 to 15 psi,
Compliance CE ADT155-02-CP15
±0.02%FS

Software ACal, PCal, Land, LogII Pressure module for ADT760-D & -MA, -13.5 to 30 psi,
ADT155-02-CP30
±0.02%FS
Warranty 1 year Pressure module for ADT760-D & -MA, -13.5 to 35 psi,
ADT155-02-CP35
±0.02%FS

Pressure module for ADT760-D & -MA, -13.5 to 50 psi,


ADT155-02-CP50
±0.02%FS

Pressure module for ADT760-MA, -13.5 to 100 psi,


ADT155-02-CP100
±0.02%FS

Pressure module for ADT760-MA, -13.5 to 150 psi,


ADT155-02-CP150
±0.02%FS

Pressure module for ADT760-MA, -13.5 to 200 psi,


ADT155-02-CP200
±0.02%FS

Pressure module for ADT760-MA, -13.5 to 300 psi,


ADT155-02-CP300
±0.02%FS

* ADT155 Pressure modules are calibrated in psi & inH2O

05 Phone: 714-998-6899 Email: [email protected] Corporate Headquarters Salt Lake City Office
Rev # 20220831 2900 Saturn Street #B 1364 West State Rd. Suite 101
Brea, CA 92821, USA Pleasant Grove, UT 84062, USA
Ordering Information
Model Number
Pressure / Process Calibration Equipment

ADT760 MA 02 CP100 DL

Pressure range:
See Model Type table Optional Accessories

Model Description Picture


02 - 0.02% full span
05 - 0.05% full span See datasheet of ADT161
10 - 0.1% full span ADT161 for more info; connection
20 - 0.2% full span cable sold separately

Internal Pressure Module Range: Pressure module


9060
connection cable
See Optional Internal Pressure
Model table.
Special Connector
ADT100-760-N
DL: Data logging to 1/4NPT quick connector

Model Type Special Connector


ADT100-760-B
to 1/4BSP quick connector
Model Number Description

Automatic Handheld Pressure Calibrator, Special Connector


ADT760-LLP ADT100-760-M
±30 inH2O to M20x1.5 quick connector
Automatic Handheld Pressure Calibrator,
ADT760-LLP-DL
±30 inH2O w/HART and data logging Special Connector
ADT100-760-N2
to 1/2NPT quick connector
Automatic Handheld Pressure Calibrator,
ADT760-D
-12.5 to 35 psi
Special Connector
Automatic Handheld Pressure Calibrator, ADT100-760-B2
ADT760-D-DL to1/2BSP quick connector
-12.5 to 35 psi w/HART and data logging

Automatic Handheld Pressure Calibrator, Pneumatic Pressure Manifold


ADT760-MA ADT128-B for ADT760, -15 to 3000 psi,
-12.5 to 300 psi
single port, 1/4 BSP F
Automatic Handheld Pressure Calibrator,
ADT760-MA-DL Pneumatic Pressure Manifold
-12.5 to 300 psi w/HART and data logging
ADT128-B2 for ADT760, -15 to 3000 psi,
* Configurations available for ADT760 units with different internal pressure single port, 1/2 BSP F
sensor range

Accessories (Included) Pneumatic Pressure Manifold


ADT128-N for ADT760, -15 to 3000 psi,
Model Quantity Picture single port, 1/4 NPT F

ADT100-760-KIT adapter Pneumatic Pressure Manifold


1 set (to 1/4BSPF, to 1/4NPTF, ADT128-N2 for ADT760, -15 to 3000 psi,
set
to M20F) single port, 1/2 NPT F
(excl ADT760-LLP)

USB to USB cable Pneumatic Pressure Manifold


1 pc ADT128-M for ADT760, -15 to 3000 psi,
(ADT760-X-DL only)
single port, M20x1.5
9816-X 110V/220V external
1 pc
power adapter
9240 DP gauge holder, rubber
9724 chargeable Li-ion
1 pc
battery

9025 test leads for 1220211087 Filter, set of 1 pc


1 sets (3 pcs)
calibrator

ADT100-760 Hose 1 pc for the ADT760-MA Soft carrying case for


9913-760-SC ADT760, test leads, and
many accessories
Pressure Hose 1 pc for the ADT760-D

Carry case for ADT760 and


9914-760
2 meters for the ADT760-LLP various accessories
Silicone Tube
1 meter for the ADT760-D

1220211206 Special connector (to be used


Adapter, quick female to ADT100-760-CNT to adapt from the ADT760 to
1 pc ADT100-760-KIT adapters)
barb
(Only for ADT760-D)
ISO17025 accredited
1 pc
certificate * Additel/Land software available for free download at www.additel.com

06 Phone: 714-998-6899 Email: [email protected] Corporate Headquarters Salt Lake City Office
Rev # 20220831 2900 Saturn Street #B 1364 West State Rd. Suite 101
Brea, CA 92821, USA Pleasant Grove, UT 84062, USA