iC60N Circuit Breakers (Curve B, C, D)

The document summarizes iC60N circuit breakers which provide circuit protection against short-circuit and overload currents for industrial applications. The circuit breakers comply with various IEC standards and provide fault indication. They are available for alternating and direct current in various voltages and currents ratings. The document lists the catalog numbers and accessories available for 1-pole and 2-pole iC60N circuit breakers.

Uploaded by

Dimaz Irawan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
166 views1 page

iC60N Circuit Breakers (Curve B, C, D)

The document summarizes iC60N circuit breakers which provide circuit protection against short-circuit and overload currents for industrial applications. The circuit breakers comply with various IEC standards and provide fault indication. They are available for alternating and direct current in various voltages and currents ratings. The document lists the catalog numbers and accessories available for 1-pole and 2-pole iC60N circuit breakers.

Uploaded by

Dimaz Irawan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Protection iC60N circuit breakers

Circuit protection
(curve B, C, D)

IEC/EN 60947-2
DB106604

DB123398

DB116619

IEC/EN 60898-1
bb iC60N circuit breakers are multi-standard circuit breakers which combine the
following functions:
vv circuit protection against short-circuit currents,
vv circuit protection against overload currents,
vv suitable for industrial isolation according to IEC/EN 60947-2, standard.
vv fault tripping indication by a red mechanical indicator in circuit breaker front face.
PB104437-40

PB104450-40

Alternating current (AC) 50/60 Hz


Breaking capacity (Icu) according to IEC/EN 60947-2 Service
Voltage (Ue) breaking
capacity
Ph/Ph (2P, 3P, 4P) 12 to 133 V 220 to 240 V 380 to 415 V 440 V
(Ics)
Ph/N (1P, 1P+N) 12 to 60 V 100 to 133 V 220 to 240 V -
Rating (In) 0.5 to 4 A 50 kA 50 kA 50 kA 25 kA 100 % of Icu
6 to 63 A 36 kA 20 kA 10 kA 6 kA 75 % of Icu
Breaking capacity (Icn) according to IEC/EN 60898-1
Voltage (Ue)
Ph/Ph 400 V
Ph/N 230 V
Rating (In) 0.5 to 63 A 6000 A

Direct current (DC)


Breaking capacity (Icu) according to IEC/EN 60947-2 Service
Voltage (Ue) breaking
capacity
Between +/- 12 to 72 V 100 to 133 V 220 to 250 V
(Ics)
Number of poles 1P 2P (in series) 3P (in series) 4P (in series)
Rating (In) 1 to 63 A 6 kA 6 kA 6 kA 6 kA 100 % of Icu

Catalogue numbers
iC60N circuit breaker
Type 1P 2P
1 1 3

2 2 4

Auxiliaries Remote tripping and indication, Remote tripping and indication,


pages 123 and 136 pages 123 and 136
Vigi iC60 Vigi iC60 add-on residual current device, page 82 Vigi iC60 add-on residual current device, page 82
Rating (In) Curve Curve
B(2) C D(1) B(2) C D(1)
0.5 A(1) A9F73170 A9F74170 A9F75170 A9F73270 A9F74270 A9F75270
1 A(1) A9F73101 A9F74101 A9F75101 A9F73201 A9F74201 A9F75201
2 A(1) A9F73102 A9F74102 A9F75102 A9F73202 A9F74202 A9F75202
3 A(1) A9F73103 A9F74103 A9F75103 A9F73203 A9F74203 A9F75203
4 A(1) A9F73104 A9F74104 A9F75104 A9F73204 A9F74204 A9F75204
6A A9F76106 A9F77106 A9F75106 A9F76206 A9F77206 A9F75206
10 A A9F76110 A9F77110 A9F75110 A9F76210 A9F77210 A9F75210
13 A(1) A9F73113 A9F74113 A9F75113 A9F73213 A9F74213 A9F75213
16 A A9F76116 A9F77116 A9F75116 A9F76216 A9F77216 A9F75216
20 A A9F76120 A9F77120 A9F75120 A9F76220 A9F77220 A9F75220
25 A A9F76125 A9F77125 A9F75125 A9F76225 A9F77225 A9F75225
32 A A9F76132 A9F77132 A9F75132 A9F76232 A9F77232 A9F75232
40 A A9F76140 A9F77140 A9F75140 A9F76240 A9F77240 A9F75240
50 A A9F76150 A9F77150 A9F75150 A9F76250 A9F77250 A9F75250
63 A A9F76163 A9F77163 A9F75163 A9F76263 A9F77263 A9F75263
Width in 9-mm modules 2 4
Accessories Pages 123 and 136 Pages 123 and 136

(1) VDE approved only. (2) only NF and VDE.

36 version: 1.1 Acti9 Catalogue 2011_12.indd