Dynanet
Lifetime extension – Keeping customers’ networks
up and running
DNWP offers Dynanet customers deliveries for
network expansions, spare parts, HW repair
service, and support services related to the former
Nokia Dynanet product family.
Dynanet is a flexible product family for 2 Mbit/s
primary access networks. High quality, flexibility,
and modularity ensure an ideal fit for both small and
large scale deployments. A broad range of interface
units for analog voice, Ethernet, slow speed data,
copper transport, and optical teleprotection can be
used in all Dynanet multiplexers.
DM2 is a primary multiplex equipment for DM2
multiplexing analog voice and signaling as well as
data channels of different bit rates into a common 2
Mbit/s frame. The heart of the equipment is a
multiplexer unit, which is common to all channel
and special units of the DM2 system.
DB2 performs branching and drop/insert functions
supporting efficient utilization of the 2 Mbit/s
connection as well as fault tolerant loop networks.
The branch and the main line signal have the same
speed and frame structure. Individual channels are DB2
connected through or branched, and the operation
is completely digital. The DB2 branching equipment
supports a full set of interface units for dropping
and inserting individual channels.
DN2 provides an efficient three-in-one node for
network flexibility and reliability. It provides cross-
connect functionality down to 8 kbit/s level with
drop/insert and multiplexing capabilities, supporting
up to 40 x 2 Mbit/s interfaces. DN2 is highly reliable
due to its modular and decentralized design as the
cross-connection functions are distributed. DN2
DN2
fully supports the implementation of loop and mesh
networks
DP10034002 1
Dedicated Network Partners Oy
www.dnwpartners.com
© 2015-2016 Dedicated Network Partners Oy
Dynanet
Interface units and other components
Dynanet interface units provide interfaces to the
2048 kbit/s transmission systems using Dynanet
multiplexers. The data interface units cover the
most frequently used interfaces to data terminals
and servers: V.35, V.11, V.24/V.28, X.21, and
G.703. The voice interface units provide subscriber
and exchange access for telephony as well as E&M Dynanet – Ethernet IU
analogue lines.
TPS64 supports transmission of teleprotection
signals in power networks. It is used together with a
digital telecommunication network like Dynanet or
Connection Master. The alarm information is
encoded into a standard 64 kbit/s digital data
channel. The equipment consists of a control unit
and channel units and it has its own dedicated
subrack.
DF2-8 optical line equipment provides digital signal
transmission on optical fibers at bit rates of 2 and 8
Mbit/s. The change-over equipment is used to
provide an alternative transmission path in case of TPS64
a line failure. In the transmit direction the change-
over equipment sends the signal to two redundant
transmission lines. In the receive direction, it
selects one of the two incoming signals. The
selection is based on the external control data
received from the protected systems.
ACL2ti is an SHDSL line terminal for data
transmission over copper pairs. It provides nx64
kbit/s up to 2 Mbit/s access over a subscriber line.
The user data is conveyed either transparently or in
a G.704 frame structure. The ACL2ti line terminal
can support alternatively one or two network ACL2ti
terminals. The line terminal is a plug-in unit and can
be installed in any Dynanet subrack.
TMS Adaptor, Smart Branching Unit, and
Supervisory Substation are components of the
Transmission Management System. TMS enables
remote localization of network faults down to station
or plug-in unit level.
In addition to the above, DNWP Dynanet offering
includes:
Subracks
Power units TMS Adaptor
Cables & accessories
DP10034002 2
Dedicated Network Partners Oy
www.dnwpartners.com © 2015-2016 Dedicated Network Partners Oy
Dynanet
Management
Network management Element management
The DNWP Network Management System is a Element management is carried out with Q1
full featured NMS with FCAPS and a powerful Agent and with element managers for the
End-to-End circuit provisioning function. End-to- respective units. With Macro STE, DB2 Manager
End circuits can be created over PDH, SDH and and DN2 Manager, it is easy to configure and
packet layers and over different generations of manage all node level settings. Also, a hand-
network elements. held Service Terminal can be used for
management.
Network topology view with map
Fault management
Configuration management
Inventory management
User management
Performance management
End-to-End circuit provisioning
The DNWP NMS enables smooth migration
from Dynanet or FMX2 to Connection Master by
supporting PDH, SDH and packet networks in
the same platform.
DP10034002 3
Dedicated Network Partners Oy
www.dnwpartners.com © 2015-2016 Dedicated Network Partners Oy
Dynanet
Application examples
Connection between PDH and SDH Access multiplexer
E1
DM2
E1
FMX2
DM2
DB2
Connection
Master
SDH E&M, SUB, EXC Ethernet
E1
E1 loop protection Data
Local cross-connect Meshed critical networks
E1, timeslot, bit
DN2
DN2
Teleprotection
Power line
Teleprotection system Teleprotection system
TPS64 TPS64
64 kbit/s 64 kbit/s
G.703 G.703
ITU-T specified
digital network
While we attempt to ensure that the information in this document is up to date and accurate, we do not warrant or accept any
responsibility or liability for the accuracy or completeness of the content, or for any loss which may arise from the use of this
document. We reserve the right to change the information in this document without prior notice.
DP10034002 4
Dedicated Network Partners Oy
www.dnwpartners.com © 2015-2016 Dedicated Network Partners Oy