FILENAME

9_CEMENT_SILOS_&_PACKING_LOCAL_NET_CONFIGURATION_REV 04.VSD

Drawing Legend Optical field cable Electrical field cable -A03.01 : Optical junction box -X45.xx : Eletrical junction block -X41.xx : Eletrical fieldbus plug -R01.01 : Active termination

=601CS100A01
TS8205SIE1

PLC Cabinet

Location
”Substation” 691 =601LV110Q01 =601LV100Q01 =602LV110Q01 =602LV100Q01 =602LV120Q01 =601LV100 =602LV100
SIPROTEC SIPROTEC SIPROTEC SIPROTEC SIPROTEC SIMOCODE SIMOCODE
Field bus Node no.:
10
Transformer Feeder Transformer Feeder Transformer Feeder Transformer Feeder Transformer Feeder
LVDB LVDB
MAC adress 601LV110T01 601LV100T01 602LV110T01 602LV100T01 602LV120T01
NetA:08.00.06.57.F0.9A
NetB:08.00.06.57.F0.9B Node no.: 41 Node no.: 42 Node no.: 43 Node no.: 44 Node no.: 45 Node no.: 11-xx Node no.: 11-xx

Substation 691
DP DP DP DP DP DP DP
Fieldbus & Interface
Electrical
Fieldbus -X45.xx

I/O Cabinet 01

SUB PLC´s 02

Field Devices 03

MCC/MDB 1 04

MCC/MDB 2 05

Active Termination
=601CS100A11 =611SI100A01 =612SI100A01 =601CS100A12 =641EI102A01 641EI303A01 641EI353A01 642EI102A01 642EI303A01 642EI353A01

Electric Room Packing


Point
AE1057PB1 S7 - 315 S7 - 315 AE1057PB1 S7 - 315 S7 - 315 S7 - 315 S7 - 315 S7 - 315 S7 - 315
01
-R01.
02 Silo Control Silo Control Packing Line 1 Bag Placer 1 Bag Placer 2 Packing Line 2 Bag Placer 1 Bag Placer 2
Profibox Profibox
LCP LCP LCP 641PM100 LCP 641AP300 LCP 641AP350 LCP 642PM100 LCP 642AP300 LCP 642AP350

- Node no.: 11 Node no.: 12 - Node no.: 13 Node no.: 15 Node no.: 16 Node no.: 14 Node no.: 17 Node no.: 18
Fieldbus & Interface
-A02.01 DP DP -A02.01 DP DP DP DP DP DP
-R01.01
-U14.01

-R01.01
-U14.01
Optical
1 2 1 2
Fieldbus -A03.01
T/R T/R T/R T/R
3 T/R
I/O Cabinet
4 T/R
5 T/R
6 T/R
7 T/R Room Silo 611 Room Silo 612
SUB PLC’s
8 T/R
9 T/R
10 T/R
11 T/R
MCC/MDB 1
12 T/R =601CS100A13 LCP =601CS100A14 661EI102A01 =662EI102A01
AE1057PB1 AE1057PB1 S7 - 315 S7 - 315

GAS Control
Profibox Profibox Big Bag No. 1 Big Bag No. 2

Field Positioned
(Client Supply)

- - Node no.: 19 Node no.: 20


-A02.01 DP
-R01.01
-U14.01

-A02.01 DP DP

-R01.01
-U14.01
1 2 1 2
T/R T/R T/R T/R

Ethernet & Interface


Optical
Gas Boosting Station
Ethernet -A03.01
1 T/R See Central Control
TCP/IP
2 T/R System Documentation

TITLE PROJECT NAME DRAWN BY DATE DRAWING NUMBER


CEMENT SILO & PACKING PROFIBUS NET CONFIGURATION (601CS100) GCC - DOHA TAM 07/08/2008 80014516
COPYRIGHT © 2006 BY DESCRIPTION REVISION APPROVED BY REVISED SECTION & PAGE
FLSmidth-DK
Local net configuration & Interface terminals 04 LPN 26/03/2009 9/1