0% found this document useful (0 votes)
141 views4 pages

Fisa Tehnica PW12C

This document provides specifications for single point load cells with maximum capacities ranging from 50 kg to 750 kg. It details key features such as accuracy class, number of load cell verification intervals, temperature coefficients, and mechanical specifications.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
141 views4 pages

Fisa Tehnica PW12C

This document provides specifications for single point load cells with maximum capacities ranging from 50 kg to 750 kg. It details key features such as accuracy class, number of load cell verification intervals, temperature coefficients, and mechanical specifications.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

PW12C…

Single point load cells

Special features

- Maximum capacities: 50 kg … 750 kg


- Aluminum

Data sheet
- High ratio of minimum verification
interval Y
- Off-center load compensation
- Complies with EMC directives
- Six-wire circuit
- Explosion protection and other options
also available

Dimensions in mm (1 mm = 0.03937 inches)


Protective covering agent in ATEX versions
(31 mm x 25 mm)

x3
18
75

16

During installation, set the overload stop and fix it in position *)

21 *) with a screw locking adhesive


(e.g. Loctite®)
60
76

8xM8
25 125 25 8
191

B2188-5.0 en HBM: public


Type PW12C...
Accuracy class1) C3 Multi Range (MR)
Number of load cell verification intervals (nLC) nLC 3000
Maximum capacity2) Emax kg 50 75 100 150 200 250 300 500 635 750
Minimum load cell verification interval,
vmin
accuracy class C3MR g 5 5 10 10 20 20 20 50 50 50
Temperature coefficient of zero signal,

±0.0140

±0.0093

±0.0140

±0.0093

±0.0140

±0.0112

±0.0093

±0.0140

±0.0110

±0.0093
accuracy class C3MR % of Cn /
TC0
10 K

Ratio of minimum verification interval Y Y 10,000 15,000 10,000 15,000 10,000 12,500 15,000 10,000 12,700 15,000
Maximum platform size mm 800 x 800
Nominal sensitivity Cn 2.0 "0.2 (Option 6: A = 2mV/V"0.1%)
mV/V
Zero signal 0 "0.1
Temperature coefficient of sensitivity3)
% of Cn /
Temperature range: +20 ... +40 °C TCc "0.0175
10K
-10 ... +20 °C "0.0117
Relative reversibility error3) dhy "0.0166
Non-linearity3) dlin "0.0166
% of Cn
Minimum dead load output return (DR) "0.0166
Off-center load error4) "0.0233
Input resistance RLC 300 ... 500
Ω
Output resistance R0 300 ... 500 (Option 6: A = 410 Ω "0.2 Ω)
Reference excitation voltage Uref 5
Nominal (rated) range of the excitation 1 ... 12
BU V
voltage
Maximum excitation voltage BU 15
Insulation resistance at 100 VDC Ris GΩ >2
Nominal (rated) range of the ambient -10 ... +40
BT
temperature
°C
Operating temperature range Btu -10 ... +50
Storage temperature range Btl -25 ... +70
Limit load at max. 100 mm eccentricity EL 150
% of
Limit lateral loading, static Elq 300
Emax
Breaking load Ed 300
Rated displacement at Emax, approx. snom mm < 0.5
Weight, approx. m kg 2.4
Degree of protection5) IP67
Material: Measuring body Aluminum
Covering agent Silicone rubber
Cable sheath PVC
1) As per OIMLR60, with PLC = 0.7
2) Maximum eccentric loading as per OIML R76
3) If the values for non-linearity (dlin), relative reversibility error (dhy) and temperature coefficient of sensitivity (TCC) are added together, they are
within the cumulated error limit specified in OIML R60.
4) Off-center load deviation per OIML R76
5) As per EN 60 529 (IEC 529)

HBM 2 B2188-5.0 en HBM: public


Cable assignment
6-wire cable connection (available cable lengths: 1.5 m; 3 m; 6 m; 12 m)

Schematic diagram of a Pancon connector (CE100F26-6), 6-pin

Shield (yellow) = cable shield connected to load


cell body
Plug-in contact 1 (white) = measurement signal (+)

1
Plug-in contact 2 (red) = measurement signal (-)

2
Plug-in contact 3 (black) = excitation voltage (-)

3
4
Plug-in contact 4 (blue) = excitation voltage (+)

5
Plug-in contact 5 (green) = sense line (+)
Plug-in contact 6 (gray) = sense line (-)
6
blue marking

Mounting and load application


The load cells are attached at the mounting holes, the load is applied at the other end. The recommended screws
and tightening torques can be found in the table below:

Maximum capacities Thread Min. property class Tightening torque1)


50...500 kg M8 10.9 35 N⋅m
635 kg, 750 kg M8 12.9 42 N⋅m
1) Recommended value for the specified property class. Please comply with the screw manufacturer's instructions with regard to screw
dimensions

Load must not be applied to the side where the cable connection is located, as this would cause a force shunt.

Platform center

Take the covering agent into


account in ATEX versions
(see dimensions)
Load application

ÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈ
ÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈÈ
Connection cable

Mounting

Spacer (customer responsible for construction)

B2188-5.0 en HBM: public 3 HBM


Product numbers
PW12C… (aluminum)
Type PW12C
Accuracy class C3-MR (OIML) (Multi Range)
Comments Cable length 3 m (6-wire)

Maximum capacity [kg] Ordering number


50 1-PW12CC3/50KG-1
75 1-PW12CC3/75KG-1
100 1-PW12CC3/100KG-1
150 1-PW12CC3/150KG-1
200 1-PW12CC3/200KG-1
250 1-PW12CC3/250KG-1
300 1-PW12CC3/300KG-1
500 1-PW12CC3/500KG-1
635 1-PW12CC3/635KG-1
750 1-PW12CC3/750KG-1

K-PW12C-… (aluminum), optional versions


Ordering number
K-PW12C

Code Option 1: Mechanical design


N -

Code Option 2: Accuracy class


MR C3-MR (OIML) (Multi Range)

Code Option 3: Nominal (rated) load


50 50 kg
75 75 kg
100 100 kg
150 150 kg
200 200 kg
250 250 kg
300 300 kg
500 500 kg
635 635 kg
750 750 kg

Code Option 4: Explosion protection


N no explosion protection 0
AI1/21 IECEx+ATEX Zone 1/21+FM, intrinsically safe II2G Ex ia IIC T6/T4 Gb/II2G Ex ia IIIC T125°C Db
AI2/22 IECEx+ATEX Zone 2/22, not intrinsically safe II3G Ex nA IIC T6/T4 Gc/II3D Ex tc IIIC T125°C Dc

Code Option 5: Cable length


1.5 1.5 m
3 3 m (standard)
6 6m
12 12 m

Code Option 6: Other


N without
A 2mV/V ±0.1% / 410 Ω ±0.2 Ω
(adjusted output, suitable for parallel connection)

K-PW12C - N - - - - -
B2188-5.0 en HBM: public

Subject to modifications. Hottinger Baldwin Messtechnik GmbH


All product descriptions are for general information Im Tiefen See 45 ⋅ 64293 Darmstadt ⋅ Germany
only. They are not to be understood as a guarantee Tel. +49 6151 803‐0 ⋅ Fax +49 6151 803‐9100
of quality or durability. E-mail: [email protected] ⋅ www.hbm.com

measure
HBM and predict with confidence 4 B2188-5.0 en HBM: public

You might also like