Hughes Point-to-Multipoint
SYSTEMS LTD.
AB9800 System Overview
HUB
(Base Station)
Hub Specifications:
2G / CDMA / 3G BTSs connected to RT
Backhaul Network
10/100 BaseT 802.11x RT WiFi / WiMax Connectivity RT
Scalable, sector by sector growth nxE1 (TDM or ATM), E3 (ATM), STM-1 (ATM), LAN interfaces ATM traffic concentration Hub can also work in PTP mode 1:N redundancy 90, 180, and 360 sectors
SECTOR
Broadband Wireless Access Fractional E1, E1, nxE1, LAN, DSL, BoPL
Radio Specifications:
Remote Specifications:
Physical: E1, STM-1, LAN Traffic: TDM, ATM, ATM IMA, IP 1:1 redundancy
ETSI 10.5, 26 & 28 GHz and China 26 GHz Access: FDD/TDMA 14 MHz Channel with 30 Mbps; 28 MHz channel with up to 92 Mbps Dynamic Adaptive modulation Range: depends on frequency, avail., 200m to 15km + 60 RTs per RF Channel
2H36677 3/8/2010
HUGHES PROPRIETARY
Evolution of AB9000 Family of PMP Products
2003: AB9400
Dual Modulation with 30 Mbps capacity ETSI 26 / 28 GHz + China 26 GHz bands TDM, IP, ATM interfaces in 2U chassis ATM Concentration Dynamic Adaptive Modulation
2000: AB9600
2007: AB9800
Triple Modulation with up to 92 Mbps capacity ETSI 10.5, 26 / 28 GHz + China 26 GHz bands TDM, IP, ATM interfaces in 1U chassis ATM Concentration Dynamic Adaptive Modulation
Triple Modulation with 45 Mbps Capacity
USA 24 / 38 + ETSI 26 GHz bands
Removable interface cards in 4U chassis
3H36677 3/8/2010
HUGHES PROPRIETARY
AB9800 Key Features
Low startup investment with single sector HT Linear expansion: match investment with revenue Low operational costs: automatic installation, etc Highest efficiency with Dynamic Modulations Assignment QPSK, 16-QAM & 64 QAM Flexible architecture: ATM, TDM and IP transport with QoS (Flexible bandwidth control DBA, Statistical Multiplexing) IP/LAN for SMEs last mile access / 2&3G backhaul Long Range: 10.5 GHZ
9 to 25km for 99.99 Avail. Rain zone A (8.2 mm/hr) 5.5 to 25km for 99.99 Avail. Rain zone K (42 mm/hr) 3 to 15km for 99.99 Avail. Rain zone P (145 mm/hr)
Carrier grade EMS (Sun-Unix)
Bottom line: lowest CapEx, lowest OpEx
HUGHES PROPRIETARY
4H36677 3/8/2010
AIReach Element Management System (EMS)
The EMS is a fully integrated carrier class management system that provides remote configuration and monitoring functions of the network sites from a central operator console.
Based on the Sun Solaris platform, the EMS utilizes a graphical user interface (GUI) based on X-Windows and Motif.
The EMS uses simple network management protocol (SNMP) to interface to the network elements.
SNMP northbound Interface to OSS Systems Built on proven software Database driven Ensures consistency and accuracy of database Persistent storage for easy data retrieval Advanced queries and reports
Page 5
HUGHES PROPRIETARY
Graphical User Interface
Easy to use standard windows interface
Easy remote access
Dial-up PC
d i g i t a l TM d i g i ta l T M
V X i n 3100 A stat o
Modem
d i g i t a l TM d i g i t al T M
PC
V X i n 3100 A stat o
WAN or PDN
d i g it a l T M di g i t a l T M
EMS Workstation
V X at n 3 A st i o 100
Router
Terminal Server
EMS Server
G-24522 C 04/23/02
Page 6
HUGHES PROPRIETARY
Spectrum, Reuse & Range
HUGHES PROPRIETARY
10GHz CEPT 14 MHz Channel Plan
According to CEPT/ERC/REC 12-05 E 2 x 150 MHz (FDD) Tx/Rx separation 350 MHz
Frequency Band 10.15 10.65 GHz
10 x 14MHz channels Downlink 10 x 14MHz channels Uplink
10 644MHz 6 MHz Guard Band
10 154MHz 4 MHz Guard Band
10 294MHz 10 504MHz 210 MHz Guard Band
8H36677 3/8/2010
HUGHES PROPRIETARY
AB9000 26/28 GHz Channel Plans
ETSI 26 GHz Band
24.5 GHz
896 MHz 64 Channels of 14 MHz Downlink 896 MHz 64 Channels of 14 MHz Uplink
25.445 GHz
25.557 GHz
26.5 GHz
1,008 MHz FDD spacing
ETSI 28 GHz Band
27.5 GHz
896 MHz 64 Channels of 14 MHz Downlink
28.4445 GHz
28.5565 GHz
896 MHz 64 Channels of 14 MHz Uplink
29.5 GHz
1,008 MHz FDD spacing
9H36677 3/8/2010
HUGHES PROPRIETARY
900 Sector Capacity
Capacity With 2 RF Channels x 14 MHz 2x14 MHz
1V 2H 1H 1H, 2V 1V, 2H
1H, 2V 1V, 2H
2V
Vertical + Horizontal Polarization
Vertical + Horizontal Polarization 8x30 Mbps = Total 240 Mbps (720 Mbps with 28 MHz channels)
HUGHES PROPRIETARY
4x30 Mbps = Total 120 Mbps
(360 Mbps with 28 MHz channels)
10H36677 3/8/2010
AB9800 Capacity
Spectral Efficiency (Bits/Sec/Hz) Data Payload Rate (Mbps) Availability
Channel Symbol Spacing Rate (MHz) (Msps) QPSK 16-QAM 64-QAM QPSK 16-QAM 64-QAM
5.6
1.6
3.2
4.8
7.4
14.8
22.3
Q1 2010
14
11.2
1.6
3.2
4.8
15.9
31.7
47.6
Now
20
16
1.6
3.2
4.8
22.3
44.5
66.8
Now
25
20
1.6
3.2
4.8
27.6
55.3
82.9
Now
28
22.4
1.6
3.2
4.8
30.7
61.4
92.2
Now
HUGHES PROPRIETARY
AB9000 System Services
ATM Mux
ATM Backhaul Network
Air Interface: 7/14 / 28 MHz channel QPSK / 16 & 64 QAM
IP Backhaul Network
10/100BT
Router, Eth. Switch
RT Interfaces:
TDM Mux
NxE1, STM-1o, 10/100 BaseT` RT interface
TDM Backhaul Network
Service Type
HT interface
STM-1o, E3, OC3c, DS3 STM-1o, E3, OC3c, DS3 STM-1o, E3, OC3c, DS3 N x T1/E1 (N=1 to 16) STM-1o, E3, OC3c, DS3
Native ATM (CBR, rt/nrt-VBR, UBR, UBR+)
STM-1o, OC3c, NxE1 (N=1 to 4 for 4E1 or 16E1 RT; N=1 to 8 for 8E1 RT) N x E1 (N=1 to 4 for 4E1 or 16E1 RT; N=1 to 8 for 8E1 RT) N x E1/T1 (N=1 to 4 for 4E1 or 8E1 RT; N= 1 to 16 for 16E1 RT) N x E1/T1 (N=1 to 4 for 4E1 or 8E1 RT; N= 1 to 16 for 16E1 RT) Ethernet (10/100 BaseT) Ethernet (10/100 BaseT) Ethernet (10/100 BaseT)
Native ATM with IMA (3G)
Structured / Unstructured CES
Unstructured T1/E1
Ethernet to ATM
Ethernet to Ethernet
Ethernet (10/100 Base T) N x E1 (N=1 to 4)
HUGHES PROPRIETARY
Ethernet to E1
12H36677 3/8/2010
2G+3G Backhaul connection option 1
NxE1 TDM
2G
RT 1
PMP Hub STM-1 Unchannelized
NxE1 CES NxE1 IMA
UMTS
Node B
STM-1
NxE1 ATM
ATM Switch
ATM STM-1 UMTS RNC
. . .
NxE1 TDM
BSC
NxE1 TDM
2G
RT N NxE1 IMA
NxE1 CES
UMTS Node B
NxE1 ATM
Note: With this connection option, one will use up the complete capacity of Channel / no HT E1 port limitation
13H36677 3/8/2010
HUGHES PROPRIETARY
2G+3G Backhaul connection option 2
TDM: N X E1 ATM: STM-1 IP: 100BaseT
TDM: NxE1 STM-1 IP: 100BaseT
ATM:
2G
TDM: N X E1 ATM: STM-1 IP: 100BaseT
NxE1 ATM
ATM NxE1
ATM Air Interface with ATM QoS
PMP Hub
AIReach RT
NxE1 E1 ATM/IMA TDM
Core Backhaul ATM STM-1 NxE1
UMTS NodeB
3G ATM Interface O&M UBR PVC Voice VBRrt PVC Data VBRnrt
2G 3G 2G+overover NxE1 TDM NxE1 TDM 3G over ATM (E3/DS3 PDH or STM-1 SDH)
UMTS RNC
BSC
G-25106 P 09/09/02
14H36677 3/8/2010
HUGHES PROPRIETARY
2G+3G Backhaul connection option 3
2G
RT 1
PMP Hub 16 X E1
NxE1 CES NxE1 IMA
UMTS
Node B
. . .
6xE1
9xE1
UMTS RNC
BSC
2G
RT 3 NxE1 IMA
NxE1 CES
UMTS Node B
Note: With this option using unstructured E1 connection, one is limited by the number of E1 ports on the HT
15H36677 3/8/2010
HUGHES PROPRIETARY
TDM Backhaul connection option 4
NxE1 TDM
RT 1
NxE1 CES
PMP Hub ADM NxE1 TDM ATM Switch Channelized STM-1
GSM
STM-1 CH
ADM
. . .
STM-1 Un-channelized
NxE1 TDM
BSC
RT N
NxE1 TDM
GSM
NxE1 CES
Note: 1. With this connection option, one will use up the complete capacity of Channel. 2. The ADM and ATM switch could be one box
16H36677 3/8/2010
HUGHES PROPRIETARY
All-IP Backhaul
All IP
IP: 100BaseT
Ethernet
Air Interface with QoS
PMP Hub
Ethernet
AIReach RT
NxT1 Ethernet TDM
Core Backhaul Ethernet
3G BTS
RNC
17H36677 3/8/2010
HUGHES PROPRIETARY
ACU-HT Interconnection Overview Red.
Sector 1 HT with ATM concentrator - Primary
To/From Sector 1 RTs
Normal Traffic Flow
STM-1 1:1 MSP STM-1 STM-1
E1/T1 #1 E1/T1 #2
Sector 2 HT - Primary
Contact Alarms
Backhaul Network
E1/T1 #3
E1/T1 #4
LAN #1
LAN #2
Maintenance Port
PWR
Hub Redundancy
STM-1/OC3 #1
IFL
SVC
To/ From Sector 2 RTs Sector 2 HT - Backup
Contact Alarms
STM-1
E1/T1 #1
E1/T1 #2
E1/T1 #3
E1/T1 #4
LAN #1
LAN #2
Maintenance Port
PWR
Hub Redundancy
STM-1/OC3 #1
IFL
SVC
Sector 1 HT with ATM concentrator - Backup
Sector 3 HT - Primary
Contact Alarms
STM-1
E1/T1 #1
E1/T1 #2
E1/T1 #3
E1/T1 #4
LAN #1
LAN #2
Maintenance Port
PWR
Hub Redundancy
STM-1/OC3 #1
IFL
Rack mountable STM-1o Y converter
STM-1
SVC
To/ From Sector 3 RTs Sector 3 HT - Backup
Contact Alarms
E1/T1 #1
E1/T1 #2
E1/T1 #3
E1/T1 #4
LAN #1
LAN #2
Maintenance Port
PWR
Hub Redundancy
STM-1/OC3 #1
IFL
SVC
Sector 4 HT - Primary
Contact Alarms
Redundant HT Hub Site with ATM Concentration
STM-1
E1/T1 #1
E1/T1 #2
E1/T1 #3
E1/T1 #4
LAN #1
LAN #2
Maintenance Port
PWR
Hub Redundancy
STM-1/OC3 #1
IFL
SVC
To/ From Sector 4 RTs Sector 4 HT - Backup
Contact Alarms
STM-1
E1/T1 #1
E1/T1 #2
E1/T1 #3
E1/T1 #4
LAN #1
LAN #2
Maintenance Port
PWR
Hub Redundancy
STM-1/OC3 #1
IFL
SVC
18H36677 3/8/2010
HUGHES PROPRIETARY
Executive Summary - Encore
Hughes has a 30 year track record and is a recognized world leader in complex wireless systems.
Reduced Capital Expenditures Increased Revenue Opportunity
Hughes expertise and background for PMP systems is unmatched.
AIReach capabilities and costeffectiveness to own and operate are unmatched.
Reduced Operating Expenditures
Spectrum Investment Protection
AIReach by Hughes is the outstanding choice.
G-22063 C 01/31/01
SYSTEMS LTD.
HUGHES PROPRIETARY