2CD474 115pcf ASD 40ksi
2CD474 115pcf ASD 40ksi
PHYSICAL PROPERTIES
Deck Type Composite Deck
Design Thickness 0.0474
Weight 2.45
Area 0.721
KSI 40
Coating G60
SECTION PROPERTIES
Ip (In4) 0.548
In (In4) 0.55
Sp (In3) 0.5
Sn (In3) 0.506
12 63/4
BARE DECK DESIGN
Bending Moment Positive (Mp/Ω) 11975
2
[ASD] MAXIMUM CONSTRUCTION CLEAR SPAN (ft-in.) FOR LIGHT WEIGHT CONCRETE 115 PCF
Slab Depth (in.) 1-SPAN 2-SPAN 3-SPAN 1-SPAN 2-SPAN 3-SPAN 1-SPAN 2-SPAN 3-SPAN
20 PSF CONSTRUCTION LOAD
7.25 (61 PSF) 9' 1" 9' 10" 10' 2" 8' 5" 8' 5" 8' 9" 7' 7" 7' 8" 7' 11"
7.5 (63 PSF) 9' 0" 9' 9" 10' 1" 8' 4" 8' 4" 8' 8" 7' 6" 7' 7" 7' 10"
4 (31 PSF) 11' 7" 12' 3" 12' 9" 9' 9" 9' 10" 10' 2" 8' 7" 8' 8" 8' 11"
4.5 (35 PSF) 11' 2" 11' 10" 12' 3" 9' 7" 9' 7" 9' 11" 8' 5" 8' 6" 8' 9"
5 (39 PSF) 10' 9" 11' 6" 11' 10" 9' 4" 9' 5" 9' 9" 8' 3" 8' 4" 8' 7"
5.5 (45 PSF) 10' 2" 10' 11" 11' 4" 9' 1" 9' 1" 9' 5" 8' 1" 8' 1" 8' 5"
6 (50 PSF) 9' 10" 10' 7" 10' 11" 8' 10" 8' 11" 9' 2" 7' 11" 8' 0" 8' 3"
6.5 (54 PSF) 9' 6" 10' 3" 10' 7" 8' 8" 8' 9" 9' 0" 7' 9" 7' 10" 8' 1"
7 (59 PSF) 9' 3" 10' 0" 10' 3" 8' 6" 8' 6" 8' 10" 7' 8" 7' 8" 7' 11"
NOTES
All section properties and strengths are reported per foot of panel width.
p = Property in positive bending; n = Property in negative bending.
Steel deck section properties were calculated in accordance with AISI S100-12.
Web crippling values are based on minmum bearing lengths of 2" for end bearing and 4" for interior bearing.
DISCAIMER:
All data, detail and speci cations included in herein are intended as a general guide for using OEG Building Materials products. These products should not be used in design or construction without
evaluation by a quali ed engineer or architect, to determine their suitability for a speci c use. OEG Building Materials assumes no liability for failure resulting f rom use or misapplication of computation,
details or speci cations contained herein. OEG Building Material assumes no liability for damages resulting f rom improper application or insulation of these products.
OEG BUIL DING M ATERIAL S - M ETAL FRAM ING M ANUFACTURERS
Slab Depth (in.) 4 (31 PSF) 4.5 (35 PSF) 5 (39 PSF) 5.5 (45 PSF) 6 (50 PSF) 6.5 (54 PSF) 7 (59 PSF) 7.25 (61 PSF) 7.5 (63 PSF)
Span (ft-in) 3' 11" 3' 10" 3' 9" 3' 8" 3' 7" 3' 6" 3' 5" 3' 5" 3' 5"
[ASD] COMPOSITE DECK SLAB YIELD MOMENT FOR LIGHT WEIGHT CONCRETE 115 PCF
Slab Depth (in.) 4 (31 PSF) 4.5 (35 PSF) 5 (39 PSF) 5.5 (45 PSF) 6 (50 PSF) 6.5 (54 PSF) 7 (59 PSF) 7.25 (61 PSF) 7.5 (63 PSF)
Yield Moment (in-kip) 29.5 35.59 42.04 48.74 55.63 62.67 69.83 73.45 77.09
[ASD] ALLOWABLE UNIFORM LIVE LOADS FOR LIGHT WEIGHT CONCRETE 115 PCF
Slab Depth (in.) 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5 9.0 9.5 10.0 10.5 11.0 11.5 12.0 12.5
4 (31 PSF) 400 400 400 400 368 316 274 239 209 184 163 145 129 115 103 92
4.5 (35 PSF) 400 400 400 400 400 384 333 291 256 225 200 178 159 142 127 114
5 (39 PSF) 400 400 400 400 400 400 396 346 305 269 239 213 190 170 153 138
5.5 (45 PSF) 400 400 400 400 400 400 400 400 354 313 277 247 221 198 178 160
6 (50 PSF) 400 400 400 400 400 400 400 400 400 358 318 284 254 228 205 185
6.5 (54 PSF) 400 400 400 400 400 400 400 400 400 400 361 323 289 259 234 211
7 (59 PSF) 400 400 400 400 400 400 400 400 400 400 388 345 307 275 246 220
7.25 (61 PSF) 400 400 400 400 400 400 400 400 400 400 400 381 341 307 277 250
7.5 (63 PSF) 400 400 400 400 400 400 400 400 400 400 400 400 359 323 291 263
Overall Slab Depth (in.) Min. Welded Wire Reinforcement as per SDI Wire Area (in2 )
4 6X6 - W1.4X1.4 0.028
4.5 6X6 - W1.4X1.4 0.028
5 6X6 - W1.4X1.4 0.028
5.5 6X6 - W2.0X2.0 0.04
6 6X6 - W2.0X2.0 0.04
6.5 6X6 - W2.0X2.0 0.04
7 6X6 - W2.0X2.0 0.04
7.25 6X6 - W2.9X2.9 0.058
7.5 6X6 - W2.9X2.9 0.058
NOTES:
Load tables are calculated using section properties based on the steel design thickness.
Shoring requirements were established in accordance with SDI C-2011.
Bending Moment and De ection formulae are in accordance with ANSI/SDI C-2017.
Span length assumes clear spans. Center-to-center spacing of supports can be used for design as a conservative assumption.
Loads greater than 200 psf are usually the result of large concentrated dynamic loads. In such cases, contact OEG for additional
design information.
DISCAIMER:
All data, detail and speci cations included in herein are intended as a general guide for using OEG Building Materials products. These products should not be used in design or construction without
evaluation by a quali ed engineer or architect, to determine their suitability for a speci c use. OEG Building Materials assumes no liability for failure resulting f rom use or misapplication of computation,
details or speci cations contained herein. OEG Building Material assumes no liability for damages resulting f rom improper application or insulation of these products.