0% found this document useful (0 votes)
27 views2 pages

Normet TP2 Pump TDS Global 20180404

The TP2 Pump is a high pressure, medium volume airless pump used for injecting polyurethane or epoxy resins in construction and mining. It has a 1:1 mix ratio and can operate at up to 210 bar pressure. The pump is robust, portable, and has a flush pump to efficiently clean the mixing head between injections. Normet provides full on-site support for pump use and applications.

Uploaded by

Sofia Taguiam
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
27 views2 pages

Normet TP2 Pump TDS Global 20180404

The TP2 Pump is a high pressure, medium volume airless pump used for injecting polyurethane or epoxy resins in construction and mining. It has a 1:1 mix ratio and can operate at up to 210 bar pressure. The pump is robust, portable, and has a flush pump to efficiently clean the mixing head between injections. Normet provides full on-site support for pump use and applications.

Uploaded by

Sofia Taguiam
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

TP2 Pump

High Pressure Pneumatic Twin Piston Injection Pump

DESCRIPTION TECHNICAL DATA

TP2 Pump

Pressure ratio 35:1


Construction Stainless Steel

Weight 70 kg

Pump output per double stroke (cm3) 80

Air requirement (lt) 6 bar 480

Maximum input air pressure 8 bar

Maximum free-flow output 25 litre min

Mix ratio 1:1

Maximum operating pressure 210 bar

PUMP GUIDELINES
Using the pump
Specific requirements for using the pump depend largely
on the type of material being injected and the application.
Please consult your local Normet representative for more
information. Always make sure that the pump is thoroughly
cleaned after use.

Cleaning the pump


Flush as much of the material out of the pump as possible
by removing the intake hoses from the material. Lift and run
the pump until satisfied that all material has been purged
from the pump.
1. Place the intake hoses into a container of TamPur
TP2 Pump is a high pressure, medium volume airless pump Cleaner with the injection hose valve open and
with a fixed ratio of 1:1 for automatic mixing systems. It is pointing into the cleaner to re-circulate the material.
used in the construction and mining industry for the
2. Run the pump under low pressure until the cleaner
injection of polyurethane or epoxy injection resins. It is
flows through the injection hose. Continue this for
robust and can be easily wheeled onto any site. The TP2
about 1 minute.
incorporates a flush pump and flush pump feed line to the
mixing head allowing for fast and efficient cleaning of the 3. Close the injection hose valve and run the pump under
mixing head between breaks in the injection sequence. low pressure until lock off. This will ensure that the
cleaner is force into all parts of the pump, in particular
Normet can provide full on-site service which includes all the pressure gauges, if fitted.
technical aspects of pump use and application details. 4. Turn off the air supply and release any built up
Please refer to your local Normet representative for further pressure through the bleed lines. Then carefully open
information. the injection hose valve to release the pressure.

Recommended Applications:
Repeat steps 3 and 4 several times until satisfied that the
TamPur (Polyurethane Resin)
injection material has been purged. Repeat step 1 to clear
TamRez (Epoxy Resin)
the pump of the TamPur Cleaner and then using fresh
cleaner repeat steps 2 to 5 to purge the pump of
contaminated cleaner as many times as necessary.

Whilst any information and/or specification contained herein is to the best of our knowledge, true and accurate, we always recommend that a trial be carried
out to confirm suitability of the product. Please note regional climatic conditions may cause a variation in the performance of the product. No warranty is given
or implied in connection with any recommendations or suggestions made by us or our representatives, agents or distributors. The information in this data
sheet is effective from the date shown and supersedes all previous data. Please check with your local Normet office to confirm that this is current issue.

TP2 Pump V1WW18 – 2018.4.4


TP2 Pump
High Pressure Pneumatic Twin Piston Injection Pump

Note: If using TamPur 116 or TamPur 117, the Part A


should be cleaned from the pump or mixing head with
clean water.

At some stage during the cleaning process, flush the bleed


valve to keep it clear and operational.

When the pump is not in use for any length of time,


(particularly overnight), after cleaning, repeat steps 1 to 5
but this time with engine oil. To ready the pump for use,
repeat steps 1 to 5 using cleaner.

Cleaning the pump is extremely important. If it is not done


correctly it will seriously impact the effectiveness and
working life of the pump. Grit and other solid particles
within the pump will score and wear away at the pump parts
and eventually stop it from operating.

HEALTH & SAFETY


TP2 Pump should only be used as directed. Our
recommendations for protective equipment should be
strictly adhered to for your personal protection.

Whilst any information and/or specification contained herein is to the best of our knowledge, true and accurate, we always recommend that a trial be carried
out to confirm suitability of the product. Please note regional climatic conditions may cause a variation in the performance of the product. No warranty is given
or implied in connection with any recommendations or suggestions made by us or our representatives, agents or distributors. The information in this data
sheet is effective from the date shown and supersedes all previous data. Please check with your local Normet office to confirm that this is current issue.

TP2 Pump V1WW18 – 2018.4.4

You might also like