13/12/22, 09:38 SIS 2.

Malfunction of the Electromagnetic Pressure Reducing Valve (EPRV) May Occur on Certain Excavators and Wheeled Excavators
2022/07/18
{5264, 5479} (M0135295-02)

SMCS - 5264, 5479 i09555712


Excavator
320 (S/N: BR61-UP; KFE1-UP; MYK1-UP; ZBN1-UP; DYT1-UP; ELW1-UP)

PIP
320 GC (S/N: BR41-UP; YTF1-UP; DKJ1-UP; KHJ1-UP; RGJ1-UP; LKS1-UP)

-
320 GX (S/N: TNG1-UP)

202 011 1
323 (S/N: BR91-UP; DWE1-UP; KPE1-UP; DWF1-UP; NDL1-UP; YBL1-UP; LTN1-UP)

2 8
323 GC (S/N: FJM1-UP)

12: /12/1 791


323 GX (S/N: WGT1-UP)
325 (S/N: JNF1-UP; TEL1-UP)

3
M0 :29-
326 (S/N: JFH1-UP; MFJ1-UP; KCK1-UP; HKP1-UP; FAY1-UP)
326 GC (S/N: EEC1; GJC1-UP; DYG1-UP) 8 3
330 (S/N: XNB1-UP; WCH1-UP; KEL1-UP)
330 GC (S/N: FEK1-UP; TML1-UP; SCZ1-UP) 1 3
© 2 529 3:00 0
0 5
335 (S/N: XBE1-UP)

Cat 2 C2
336 (S/N: SP91-UP; JHD1-UP; HDF1-UP; WFF1-UP; FEL1-UP; RDL1-UP; SYL1-UP; YBN1-UP; MZR1-UP; DKS1-UP; NDW1-UP; GDY1-UP)

e
336 GC (S/N: GSF1-UP; DWL1-UP; JFW1-UP; HBY1-UP)

r
Con pilla terpia
340 (S/N: WLE1-UP; KFG1-UP; EFH1-UP; TYH1-UP; GMJ1-UP; TMK1-UP; WFK1-UP; FKN1-UP; WDN1-UP; SZT1-UP; XBZ1-UP)
Material Handler
MH3040 (S/N: NTR1-UP)

fide r: llar
Inc
Wheeled Excavator
M314 (S/N: KA31-UP)
ntia .
l Ye
M318 (S/N: KE71-UP)

llow
Reference: Special Instruction, M0089945 , "Procedure to Purge Air from the Pilot Circuit on Certain Next Generation Hydraulic Excavators"

Reference: Testing and Adjusting, M0086311 , "336336 GC340 Excavator" Hydraulic System Air - Purge 

Revision History:
Revision  Summary of Changes 
Updated solenoid valve group part number, references, and added footnotes to the part table. Removed machine effectivity for 312
02 
through 317. Added graphic for "Stick Out" function solenoid. 
01  Changed wording in problem section and title. 

Table 1

Introduction
The problem that is identified below does not have a known permanent solution. Until a permanent solution is known, use the solution that is
identified below.

Problem
Rough operation of the front, swing, or travel may occur due to malfunction of the Electromagnetic Pressure Reducing Valve (EPRV). The spring
inside the EPRV may break.

Solution
If rough operation occurs, follow the procedure outlined below:

Do not operate or work on this product unless you have read


and understood the instructions and warnings in the relevant
Operation and Maintenance Manuals and relevant service
literature. Failure to follow the instructions or heed the warnings
could result in injury or death. Proper care is your responsibility.

https://sis2.cat.com/#/print-preview/service/%257B%2522title%2522%253A%2522Malfunction%2520of%2520the%2520Electromagnetic%2520Pressure%2520Reducing%2520Valve%2520(EPRV)%2520May%2520… 1/3
13/12/22, 09:38 SIS 2.0

1. Purge the air from the hydraulic lines. Refer to Special Instruction, M0089945 , "Procedure to Purge Air from the Pilot Circuit on Certain
Next Generation Hydraulic Excavators".

Illustration 1 g07492591
"Stick Out" function solenoid valve location.
(1) 627-2304 Solenoid Valve Gp

Illustration 2 g07496843
(1) 627-2304 Solenoid Valve Gp ()
(A) Valve body

2. If rough operation continues, replace the failed parts with new ones. Refer to Table 2 for the list of required parts.

3. After replacement, purge the air in the hydraulic lines and fan pump. Refer to Special Instruction, M0089945 , "Procedure to Purge Air from
the Pilot Circuit on Certain Next Generation Hydraulic Excavators" and Testing and Adjusting, "Excavator"Hydraulic System Air - Purge"".

4. Calibrate the new valve. Refer to Testing and Adjusting, Implement - Calibrate for additional information.

Required Parts 
Item  Qty  Part Number  Part Name 
1  1  627-2304(1)  Solenoid Valve Gp 
2  1  585-9230(2)  Solenoid Valve Gp 

Table 2
(1)
(2) Only for the "Stick Out" function.
For all functions except the "Stick Out" function.

PIP-10118791
2022/12/13
https://sis2.cat.com/#/print-preview/service/%257B%2522title%2522%253A%2522Malfunction%2520of%2520the%2520Electromagnetic%2520Pressure%2520Reducing%2520Valve%2520(EPRV)%2520May%2520… 2/3
13/12/22, 09:38 SIS 2.0

12:31:23-03:00
i08717993
© 2022 Caterpillar Inc.
Caterpillar:
Confidential Yellow

https://sis2.cat.com/#/print-preview/service/%257B%2522title%2522%253A%2522Malfunction%2520of%2520the%2520Electromagnetic%2520Pressure%2520Reducing%2520Valve%2520(EPRV)%2520May%2520… 3/3

You might also like