0% found this document useful (0 votes)
280 views1 page

CV DWG 0377

The document shows a diagram of multiple sump pits connected by vent pipes. Each sump pit is 450x450x450 mm in size and has a manhole opening at an elevation of 0.20m. The sump pits are connected by 50mm PVC vent pipes arranged at 10 pipes spaced 150mm center to center. The sump pits are part of a water piping system connecting raw water to an RO plant.

Uploaded by

Priyanka Guleria
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
280 views1 page

CV DWG 0377

The document shows a diagram of multiple sump pits connected by vent pipes. Each sump pit is 450x450x450 mm in size and has a manhole opening at an elevation of 0.20m. The sump pits are connected by 50mm PVC vent pipes arranged at 10 pipes spaced 150mm center to center. The sump pits are part of a water piping system connecting raw water to an RO plant.

Uploaded by

Priyanka Guleria
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Ø50MM PVC

VENT PIPE

10Ø@150C/C 450x450x450 MM
SUMP PIT

MANHOLE OPENING
EL.(+)0.20M
Ø50MM PVC
VENT PIPE
Ø50MM PVC
VENT PIPE
450x450x450 MM
SUMP PIT

MANHOLE OPENING
EL.(+)0.20M

RO WATER RAW WATER

10Ø@150C/C

10Ø@150C/C RO PLANT

450x450x450 MM 450x450x450 MM 450x450x450 MM


SUMP PIT SUMP PIT SUMP PIT

Ø50MM PVC Ø50MM PVC Ø50MM PVC


VENT PIPE VENT PIPE VENT PIPE
MANHOLE OPENING MANHOLE OPENING MANHOLE OPENING
EL.(+)0.20M EL.(+)0.20M EL.(+)0.20M

Ø100MM PVC PIPE


INLET PIPE
LOCATION AS PER SITE

16Ø@125C/C
(TYPICAL) MURRAM FILLING

16Ø@125C/C
(TYPICAL) PVC WATER STOPPER
150X150MM HAUNCH (TYP)
RO WATER RO WATER RAW WATER Y8 @ 200mm C/C (TYP)
THROUGHOUT (TYP.)

12Ø@150C/C

12Ø@150C/C

50 THK.
Ø100MM PVC PIPE P.C.C. 1:3:6
WELL COMPACTED
EARTH

SECTION B - B

PLAN OF WATER TANK


R/F BENT INTO WALL
(300mm AFTER BEND)

LIFTING
HOOK 2 NOS. 10Ø B/W
RCC WALL 600x600
OPENING FOR 4 NOS. 10Ø B/W
MAN HOLE

450x450x450 MM 450x450x450 MM 450x450x450 MM


SUMP PIT SUMP PIT SUMP PIT

Ø50MM PVC Ø50MM PVC Ø50MM PVC


VENT PIPE VENT PIPE VENT PIPE
MANHOLE OPENING MANHOLE OPENING MANHOLE OPENING
EL.(+)0.20M EL.(+)0.20M EL.(+)0.20M

PLAN OF MANHOLE COVER TYP. REINFORCEMENT


DETAIL OF CUTOUT IN TOP
SLAB
COVER LIFTING HOOK

L50x50x6
DETAIL - 1

16Ø@125C/C 16Ø@125C/C
(TYPICAL) (TYPICAL)

16Ø@125C/C 16Ø@125C/C 5-8 Ø(B/W)


(TYPICAL) (TYPICAL) EDGE ANGLE IN SLAB
10Ø@200 C/C COVER L65x65x5

SECTION C - C

SECTION D-D

Ø50MM PVC Ø50MM PVC


VENT PIPE VENT PIPE 12Ø BAR
BEND TO
SHAPE

10Ø@150C/C 10Ø@150C/C OUTLET PIPE 10Ø@150C/C


L 50X50X6 WITH
INLET PIPE 25X5THK. 350LG.
LOCATION AS PER SITE MS LUGS @ 500
10Ø@150C/C 10Ø@150C/C 10Ø@150C/C c/c REINF.(12Ø)
RUNGS RUNGS RUNGS
Ø16@300C/C Ø16@300C/C Ø16@300C/C

DETAIL - 01 DETAIL OF LIFTING HOOK

16Ø@125C/C 16Ø@125C/C
(TYPICAL) (TYPICAL)

16Ø@125C/C 16Ø@125C/C 16Ø@125C/C


(TYPICAL) (TYPICAL) (TYPICAL)

16Ø@125C/C
(TYPICAL)
PVC WATER STOPPER
THROUGHOUT (TYP.) TANK WALL
Ø100MM PVC PIPE
PVC WATER STOPPER
150X150MM HAUNCH (TYP) THROUGHOUT (TYP.)
MURRAM FILLING 12Ø@150C/C 12Ø@150C/C Y8 @ 200mm C/C (TYP) 12Ø@150C/C 12Ø@150C/C 12Ø@150C/C MURRAM FILLING
(TYPICAL) (TYPICAL) (TYPICAL) (TYPICAL) (TYPICAL)
SLOPE 1:200 SLOPE 1:200 SLOPE 1:200 SLOPE 1:200

16Ø RUNGS
12Ø@150C/C 50 THK. 12Ø@150C/C 50 THK. 12Ø@150C/C @300 C/C
(TYPICAL) P.C.C. 1:3:6 P.C.C. 1:3:6
1
1

50 THK.
TYP. DETAIL OF RUNG LADDER
P.C.C. 1:3:6

WELL COMPACTED
EARTH
SECTION A-A