Boll Duplex Type 2.04.5

The document summarizes a BOLL Duplex Filter Type 2.04.5 for filtration of liquids with flange connections from 25-80mm. The duplex filter allows for changeover during operation without pressure loss by bringing one filter chamber online while isolating the dirty one for manual cleaning when the maximum pressure drop is reached. It operates by filtering liquids to protect plant components and can filter down to 10 microns at pressures up to 25 bars.

Uploaded by

Phung Van Hiep
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
136 views2 pages

Boll Duplex Type 2.04.5

The document summarizes a BOLL Duplex Filter Type 2.04.5 for filtration of liquids with flange connections from 25-80mm. The duplex filter allows for changeover during operation without pressure loss by bringing one filter chamber online while isolating the dirty one for manual cleaning when the maximum pressure drop is reached. It operates by filtering liquids to protect plant components and can filter down to 10 microns at pressures up to 25 bars.

Uploaded by

Phung Van Hiep
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

BOLL Duplex Filter

TYPE 2.04.5
with flange connections DN 25 – DN 80
APPLICATION available with heating
Filtration of all liquids. For installation
into suction or pressure pipework to
protect plant components (valves,
pumps, pressure gauges, nozzles etc.)
preventing accumulation of dirt and
sludge.

OPERATION
The Duplex Filter 2.04.5 allows
change-over during operation with-
out pressure-loss. The filter is compact
and easy to maintain, requiring only
manual cleaning when maximum al-
lowable pressure drop is reached.
When maximum pressure drop is
reached the standby filter chamber is
brought on line simultaneously as the
dirty one is isolated by means of the
change-over valve. After venting, the
dirty element can be removed, cleaned
and refilled to be the standby filter
chamber.

Q
[m3/h]
V = 1 m/s

V = 2 m/s

V = 3 m/s

V = 4m/s

100
00
90
80
170.5
70
60 110
.390 
50
40
110
.260 
30
.2 10
20 110

15 45
90.1
10 95
CLEANING TECHNICAL CHARACTERISTICS
9 90.0
8
7
6
• Switch change-over valve to clean • Filter housing of ductile iron; inter-
5
4 filter chamber nally nickel lined for water application
3
• Release pressure in the contaminat- • Change-over valve of cast iron; water
2

ed filter chamber by means of vent- filters rubber-lined


1
0,1 0,2 0,3 0,5 0,7 p [bar] ing screw • Optionally star-pleated  or basket
Differential-pressure p as function of
flow Q with oil of viscosity 50 cst and
• Lift the cover of the contaminated  filter element, star-pleated ele-
filtration degree 40 microns. filter chamber ment also available as disposable
• Remove filter element filter element
OPTIONAL ACCESSORIES • Soak filter element in cleaning fluid, • Filter fineness: 10 microns to 5 mm
Differential pressure indicator type e.g. BOLL-CLEAN 2000, and clean • Operating pressure up to 25 bars
4.36 can be supplied fitted at factory. with compressed air
The filter elements can be fitted with For details see operating instructions
magnetic bars. manual ”maintenance and servicing”.
T H E D E TA I L S
Z45540 – Type 2.04.5.

BOLL & KIRCH Filterbau GmbH • P. O. Box 1420 • D- 50143 Kerpen • Siemensstr. 10-14 • D- 50170 Kerpen


Tel.: +49 (0) 2273 562-0 • Fax: +49 (0) 2273 562-22 3 • e-mail: [email protected] • Internet: www.bollfilter.com