ELAN SHINE
Series
Bifacial PV Modules
MBB P-Type PERC Half-cut
ASB-M10-144-AAA (AAA=520-545)
144 Cells | 520-545 Wp
Highlights
Higher generation due to bifacial technology
MBB cell technology - Up to 70 ± 5 %
excellent anti- bifaciality Factor
microcracking performance
with more balanced interior
stress: grid pattern current
path, lower cost
Longer Product life and Least degradation for LID,
performance -0.45% year LeTID
over year degradation with
Warranty based on Power 30 years warranty on power
Adani Linear Warranty STD Linear Warranty
98.00%
Modules made with Ga Excellent PID resistance
doped wafer, Smart
soldering, 10BB
84.95%
5 10 15 20 25 30
Dimensions in mm
Technical Data
Multi Irradiance Curve Bifacial
M10-144 HC Cell Module
Cell temp: 25°C
14 Incidence Irradiance = 1000 W/m2 540 Wp
12
2
Incidence Irradiance = 800 W/m
429 Wp
10
Current (A)
Incidence Irradiance = 600 W/m2 320 Wp
8
6 Incidence Irradiance = 400 W/m
2
212 Wp
4
Incidence Irradiance = 200 W/m2 103 Wp
2
0
0 10 20 30 40 50 60
Short side Long side Voltage (V)
Frame Frame
Peak power, (0 ~+ 4.99 Wp)
Pmax(Wp) 520 525 530 535 540 545 TC of open circuit voltage ( ) -0.29% /°C
Maximum voltage, Vmpp (V) 41.18 41.34 41.49 41.64 41.80 41.94
TC of short circuit current ( ) 0.051% /°C
Maximum current, Impp (A) 12.65 12.73 12.79 12.86 12.93 13.01
TC of power ( ) -0.37% /°C
Open circuit voltage, Voc (V) 48.60 48.78 48.95 49.12 49.32 49.48
Short circuit current, Isc (A) 13.41 13.48 13.55 13.63 13.71 13.79 Maximum system voltage 1500 VDC (IEC & UL)
Module efficiency (%) 20.25 20.44 20.64 20.83 21.03 21.22 NOCT 45°C ± 2°C
*STC: Irradiance 1000 W/m², cell temperature 25°C, Air mass AM 1.5 according to EN Temperature range -40°C to + 85°C
60904-3. Average efficiency reduction is approx. 3% at 200 W/m² according to
EN 60904-1. Expect Pmpp, all other parameter have tolerance of +/-3%,
measurement uncertainty <3%.
Electrical Characteristics with different rear side 2266 mm
power gain (Reference 525 Wp Front) 1133 mm
35 mm
28.0 kg
Bifaciality Gain 10% 15% 20% 25%
IP68; Junction box
Peak power, (0 ~+ 4.99 Wp) Pmax(Wp) 575 600 630 650
300 mm length cable, MC4 compatible
Maximum voltage, Vmpp (V) 41.34 41.35 41.36 41.37 connectors
Maximum current, Impp (A) 13.89 14.51 15.24 15.72 Class A (Safety class II)
Open circuit voltage, Voc (V) 48.36 48.36 48.36 48.36 High Transmission ARC glass 3.2 mm
Short circuit current, Isc (A) 15.01 15.66 16.47 17.01
Module efficiency (%) 22.39 23.37 24.54 25.32 144 Half-cut mono-crystalline P-type
PERC bifacial solar cells; Multi bus bar
High volume resistivity and low MVTR
Transparent Backsheet
MSEL/MDL/PM/Rev0
Anodized Frame
Pallets / Container 20 Pieces / Container 620 Design Mechanical load 3600 Pa-downward; 1600 Pa-Upward
Safety Factor for Mechanical load 1.5
Note:
• The specifications included in this datasheet are subject to change without notice. 30 A
• The electrical data given here is for reference purpose only.
• Please confirm your exact requirements with the sales representative while placing your order.
*Caution: ** Warranty:
Please read safety and installation instructions before using the product. Please read Adani solar warranty documents thoroughly.
Warranty and certifications
Product warranty** 12 years of product warranty
Performance guarantee** Power degradation <2.0% in first year and <0.45% / year in 2-30 years
Approvals and certificates :
IEC 61215, IEC 61730, UL 61730, BIS, IEC 61853-1,IEC 62782,IEC 61853-2
# IEC 61701, IEC 60068-2-68, IEC 62716
# Certifications are under process