IntegriFuse Processor Error Codes
Code Fusion Report Message Code Indication Cause Download Report Column
ERROR 2.0! “FRQLEr” Main_Frequency_Lo_Error Network frequency is too low Freq Min
Meaning: Processor cannot function because the input power supply frequency is out of range on the low side.
Trouble Shooting Recommendation: Check the frequency of the input power source voltage to make sure the output frequency is within the processors
operating range while under a load. Output frequency should be 60Hz +/- 10Hz
Solution: Change Power Source
Code Fusion Report Message Code Indication Cause Download Report Column
ERROR 2.1! “FRQHEr” Main_Frequency_Hi_Error Network frequency is too high Freq Max
Meaning: Processor cannot function because the input power supply frequency is out of range on the high side.
Trouble Shooting Recommendation: Check the frequency of the input power source voltage to make sure the output frequency is within the processors
operating range while under a load. Output frequency should be 60Hz +/- 10Hz
Solution: Change Power Source
Code Fusion Report Message Code Indication Cause Download Report Column
Network frequency is irregular or
ERROR 3.0! “FREQEr” N0_Frequency Freq Min & Freq Max
has failed.
Meaning: Processor cannot function due to irregularities or a failure in the input power supply frequency.
Trouble Shooting Recommendation: Check the frequency of the input power source voltage to make sure the output frequency is within the processors
operating range while under a load. Output frequency should be 60Hz +/- 10Hz
Solution: Change Power Source
Code Fusion Report Message Code Indication Cause Download Report Column
Power supply input voltage does not
ERROR 4 “LinLErr” N0_Voltage_IN VLine Min
exist.
Meaning: Processor cannot function due to a lack of power being supplied to the processor.
Trouble Shooting Recommendation: Check the Voltage output on the power supply with a multi-meter or the Processor's meter function to make sure
the power being supplied meets the Processors voltage input requirements. Check the breakers or relays and make sure they are all on and in in the
correct position. Make sure that an adapter or pigtail is not being used to connect to the processor. Check the Processors power cord and make sure that
plug has not been modified in any way. If an extension cord is being used, make sure it is not damaged in any way, that it is the recommended length and
has the recommended wire gauge.
Solution: Change Power Source
Code Fusion Report Message Code Indication Cause Download Report Column
Power supply input voltage is too
ERROR 4.0! “LinLEr” Main_Voltage_Lo_Error VLine Min
low.
Meaning: Processor cannot function due to Power Supply Voltage is outside of the required range on the low side.
Trouble Shooting Recommendation: Check the Voltage output on the power supply with a multi-meter or the Processor's meter function to make sure
the power being supplied meets the Processors voltage input requirements. Some generators have outlets that allow you to supply both 120v and 240v
through the same outlet. Check the breakers or relays for those outlets and make sure they are all in the correct position. Make sure that an adapter or
pigtail is not being used to connect to the processor. Check the Processors power cord and make sure that plug has not been modified in any way. If an
extension cord is being used, make sure it is the recommended length and has the recommended wire gauge.
Solution: Change Power Source
270 Parkade Court, Peachtree City, GA 30269
www.integrityfusion.com
IntegriFuse Processor Error Codes
Code Fusion Report Message Code Indication Cause Download Report Column
Power supply input voltage is too
ERROR 4.1! “LinHEr” Main_Voltage_Hi_Error VLine Max
high.
Meaning: Processor cannot function due to Power Supply Voltage is outside of the required range on the high side.
Trouble Shooting Recommendation: Verify the power supply voltage output at the outlet using a multi-meter or the Processors on-board meter
function. Some generators have outlets that allow you to supply both 120v and 240v through the same outlet. Check the breakers or relays for those
outlets and make sure they are all in the correct position.
Solution: Change Power Source
Code Fusion Report Message Code Indication Cause Download Report Column
ERROR 20! “HTAErr” High_Temp_Error Ambient temperature is too high Temperature
Meaning: Ambient temperature is out of range and Processor cannot function because the outside (ambient) temperature is too high.
Trouble Shooting Recommendation: If the outside temperature is over 115 degrees F the processor will not be able to function without taking steps to
reduce the temperature in the fusion area.
Solution: Protect the work site where the fusion is taking place with a tent in order to get to a suitable ambient temperature.
Code Fusion Report Message Code Indication Cause Download Report Column
ERROR 21! “LTAErr” Low_Temp_Error Ambient temperature is too low Temperature
Meaning: Ambient temperature is out of range and Processor cannot function because the outside (ambient) temperature is too low.
Trouble Shooting Recommendation: If the outside temperature is below -10 degrees F the processor will not be able to function without taking steps to
increase the temperature in the fusion area.
Solution: Use of a tent, heaters and/or heating blankets may be required to get to a suitable ambient temperature.
Code Fusion Report Message Code Indication Cause Download Report Column
ERROR 23! “THTErr” Transfo_Temp_Error Transformer temperature is too high
Meaning: The internal temperature of the processor is too high.
Trouble Shooting Recommendation: Temperature of the processor’s transformer is too high and internal protection disables the device.
Solution: Shade the processor and leave the processor on and allow the fan to dissipate the heat.
Code Fusion Report Message Code Indication Cause Download Report Column
ERROR 24! “ChsHTE” CHSS_Temp_High Frame temperature is too high
Meaning: The temperature of the processor chassis is too high.
Trouble Shooting Recommendation: Heavy use of the control unit. Poorly ventilated work environment.
Solution: Turn processor off and wait until the frame chassis has cooled down. Placing it in a cooler environment may speed up the process.
270 Parkade Court, Peachtree City, GA 30269
www.integrityfusion.com
IntegriFuse Processor Error Codes
Code Fusion Report Message Code Indication Cause Download Report Column
ERROR 30! “NLoadE” Load_Open_Error Open Circuit in fitting
Meaning: Indicates an open circuit in the fitting due to compromised contact or a break in the fusion coil. This error can be displayed anytime within the
fusion cycle.
Trouble Shooting Recommendation: Make sure the terminal pin connections are tight and secure. Make sure you are using the correct size pin
adapters. Check for oxidation, wear, or bad contact. Check for continuity across the fusion coil.
Solution: Check leads to make sure tips are not dirty, are correct size, and there is not oxidation on the tips or terminal pins. Replace the damaged or
failed fitting.
Code Fusion Report Message Code Indication Cause Download Report Column
Resistance on the fitting is too low Nominal Resistance &
ERROR 32! “NLoadE1” Load_Measure_Error1
Measured Resistance
Meaning: Indicates the resistance measured across the fusion coil is too low or not within range. Possible sort circuit in fusion coil,
Trouble Shooting Recommendation: Check for continuity across the fusion coil. Make sure the terminal pin connections are tight and secure. Make sure
you are using the correct size pin adapters. Check for oxidation, wear, or bad contact.
Solution: If no continuity across the fusion coil, replace the damaged or failed fitting
Code Fusion Report Message Code Indication Cause Download Report Column
Resistance on the fitting is too high Nominal Resistance &
ERROR 33! “NLoadE2” Load_Measure_Error2
Measured Resistance
Meaning: Indicates the resistance measured across the fusion coil is too high or not within range.
Trouble Shooting Recommendation: Can be caused by dirty or compromised contact between the fittings’ terminal pins and the processor leads. Can
also be caused by increased resistance in the fusion coil in a fusion attempt and the re-fusing is attempted before the coil reaches ambient temperature
again. Can also be due to incorrect data in the fittings barcode.
Solution: Check the terminal pin contacts. Allow fitting to cool to ambient temperature if attempting to re-fuse the fitting in either barcode or Manual
mode. Replace the fitting if defective.
Code Fusion Report Message Code Indication Cause Download Report Column
ERROR 34.0! “IoutEr” Out_Current_Error Current output is not correct IMin
Meaning: Indicates the current flow (amperage draw) from the processor to the fitting is not correct.
Trouble Shooting Recommendation: If the lead tips or terminal pin connections are too loose, an arc can be produced which will result in a sudden surge
in amperage draw. This can cause create an open circuit in the terminal pin area or in the fusion coil. Check for continuity across the fusion coil
Solution: Check for continuity across the fusion coil. Replace the fitting if defective.
Code Fusion Report Message Code Indication Cause Download Report Column
Before the fusion: Current output
ERROR 34.1! “I2SCHE” Current_SCH_Error IMax
request is higher than possible
Meaning: This error will manifest before the fusion attempt due to the fitting calling more current than is possible due to the electronic limitation
settings.
Trouble Shooting Recommendation: Visually check the fitting for damage in the terminal pin and/or the fusion coil area that may have caused a short
circuit. Damage could have been caused by rough handling, mishandling, improper storage and transportation related issues.
Solution: Check for continuity across the fusion coil. Replace the fitting if defective.
270 Parkade Court, Peachtree City, GA 30269
www.integrityfusion.com
IntegriFuse Processor Error Codes
Code Fusion Report Message Code Indication Cause Download Report Column
During the fusion: Current output
ERROR 34.2! “I1SCHE” Out_SCH_Curr_Error IMax
request is higher than possible
Meaning: This error will manifest during the fusion attempt due to the fitting calling more current than is possible due to the electronic limitation settings.
Trouble Shooting Recommendation: Visually check the fitting for damage in the terminal pin and/or the fusion coil area that may have caused a short
circuit. Damage could have been caused by rough handling, mishandling, improper storage and transportation related issues.
Solution: Check for continuity across the fusion coil. Replace the fitting if defective.
Code Fusion Report Message Code Indication Cause Download Report Column
ERROR 35! “VoutEr” V_Our_Error Possible processor issue
Meaning: An anomaly found in the processors output voltage due to a possible short circuit, a internal system overload or the power supply fuse being
damaged.
Trouble Shooting Recommendation:
Solution: Contact Technical Support at 1 -770-632-7530
Code Fusion Report Message Code Indication Cause Download Report Column
A difference between measured
ERROR 36! “LoadE3” Load_Measure_Error3
resistance and parameters
Meaning: Indicates an unacceptable difference between the resistance parameters recorded in the barcode and those measured in the fitting.
Trouble Shooting Recommendation: Can be caused by increased resistance in the fusion coil if re-fusing of a fitting is attempted before it reaches
ambient temperature. Can also be due to incorrect data in the fittings barcode and/or a manufacturing defect.
Solution: After the fitting cools back down to ambient temperature, you may try to re-fuse the fitting in manual mode or you can replace the fitting.
Code Fusion Report Message Code Indication Cause Download Report Column
ERROR 38! “LoadSE” Load_SCH_Error Short circuit during fusion process
Meaning: Bad fusion joint
Trouble Shooting Recommendation: Typically caused by the rapid and excessive movement of molten material during the fusion process that is often
associated with excessive gaps found in the fusion zone. (short-stab, mis-stab, misalignment, binding situations)
Solution: Replace the fitting
Code Fusion Report Message Code Indication Cause Download Report Column
ERROR 39.0! "VCtrEr" Control_Voltage_Error Output voltage not stable
Meaning: The voltage being supplied to the processor is not consistent or stable.
Trouble Shooting Recommendation: Check the generator and make sure that the throttle control is on "full". Ensure that any throttle control switches
(econ mode, throttle control) are in the off position.
Solution: May need to replace the power supply
270 Parkade Court, Peachtree City, GA 30269
www.integrityfusion.com
IntegriFuse Processor Error Codes
Code Fusion Report Message Code Indication Cause Download Report Column
ERROR 39.1! "VoutEr" Out_Voltage_Error Output voltage out of limit
Meaning: The voltage being supplied to the processor is not within limits. It is either too high or too low.
Trouble Shooting Recommendation: Check the generator and make sure that the throttle control is on "full". Ensure that any throttle control switches
(econ mode, throttle control) are in the off position. A generator with a dirty voltage output can damage the Servo Card.
Solution: Connect to a stable power source or May need to replace the power supply. May need to check the Servo Card.
Code Fusion Report Message Code Indication Cause Download Report Column
General error due to unexpected
ERROR 41! "GenErr" General_Error
conditions.
Meaning: Fusion process experienced unexpected conditions
Trouble Shooting Recommendation: If this happens 3 times in succession contact technical support. 1-770-632-7530
Solution:
Code Fusion Report Message Code Indication Cause Download Report Column
ERROR 42! "SrvErr" Servo_Error Generic error
Meaning: The Processors Servo Controller assisting the welding is defective.
Trouble Shooting Recommendation: Shut off the device and restart.
Solution: If the problem continues, contact technical support. 1-770-632-7530
Code Fusion Report Message Code Indication Cause Dow
ERROR 43! "SynkEr" Sync_Error Generic error
Meaning: Error associated with either calibration problems or electromechanical problems in the processor.
Trouble Shooting Recommendation: A defect in the Processors hardware has been detected.
Solution: Contact technical support. 1-770-632-7530
Code Fusion Report Message Code Indication Cause Download Report Column
ERROR 44! "HFCEr" HW_Servo_Error_FCTRL Power Controller defective
Meaning: A defect in the Processors hardware has been detected
Trouble Shooting Recommendation:
Solution: Contact technical support. 1-770-632-7530
Code Fusion Report Message Code Indication Cause Download Report Column
ERROR 45! "SwErr" SW_Error Code error reception.
Meaning: Possible defective internal communication or software error.
Trouble Shooting Recommendation: No solution. Shut off the device and restart. If message displays again,
Solution: Contact technical support. 1-770-632-7530
270 Parkade Court, Peachtree City, GA 30269
www.integrityfusion.com
IntegriFuse Processor Error Codes
Code Fusion Report Message Code Indication Cause Download Report Column
ERROR 50 "UsrStp" User_Stop_Error Welding error
Meaning: The user pressed the stop button during the fusion cycle.
Trouble Shooting Recommendation:
Solution: Wait for the fitting to cool to ambient temperature and re-fuse the fitting.
Code Fusion Report Message Code Indication Cause Download Report Column
ERROR 50! "UsrStp" User_Stop_Error Welding Stop
Meaning: The user pressed the stop button during the fusion cycle.
Trouble Shooting Recommendation:
Solution: Review installation instructions before restarting fusion.
Code Fusion Report Message Code Indication Cause Download Report Column
ERROR 70! "MemErr" Memory_Writing Full Memory or DMS Failure
Meaning:
Trouble Shooting Recommendation:
Solution: Contact technical support. 1-770-632-7530