0% found this document useful (0 votes)
259 views72 pages

Catalogue Borri EN OMG60326revC 07-22 90years PDF

This document is a catalogue for UPS and critical power solutions from Borri. It provides an overview of Borri's 1-phase and 3-phase UPS products for applications such as computers/peripherals, data centers, networks, servers, industrial controls, process automation, medical equipment, and emergency systems. The catalogue lists UPS product lines ranging from 450VA to 21MW that are suitable for these different applications. It also describes Borri's services and global operations supporting critical power solutions.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
259 views72 pages

Catalogue Borri EN OMG60326revC 07-22 90years PDF

This document is a catalogue for UPS and critical power solutions from Borri. It provides an overview of Borri's 1-phase and 3-phase UPS products for applications such as computers/peripherals, data centers, networks, servers, industrial controls, process automation, medical equipment, and emergency systems. The catalogue lists UPS product lines ranging from 450VA to 21MW that are suitable for these different applications. It also describes Borri's services and global operations supporting critical power solutions.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 72

www.borri.

it

UPS & CRITICAL POWER


CATALOGUE
English
UPS & CRITICAL POWER CATALOGUE
CONTENTS Who we are 06

CRITICAL POWER SOLUTIONS 08


For computers and peripherals, data centres, networks
and servers

CRITICAL POWER SOLUTIONS 10


For industrial controls, process automation, medical
equipment, building automation and emergency systems

GIOTTO 14
LINE INTERACTIVE 1-PHASE UPS 450-2000 VA
For computers and peripherals

GALILEO 16
ON-LINE 1-PHASE UPS 1000-3000 VA
For networks and servers

LEONARDO 18
ON-LINE 1-PHASE UPS 6-10 kVA
For networks and servers, small data centres

POWER GUARDIAN 20
1-Phase UPS monitoring software

B8031FXS - B8033FXS 22
3/1- AND 3/3-PHASE UPS 10-20 kVA
For networks and servers, industrial controls
and process automation, medical equipment and
building automation

www.borri.it
INGENIO COMPACT 26 UPSAVER 3VO 50
3-PHASE UPS 10-20 kVA/kW MODULAR 3-PHASE UPS 670 kW - 2.67 MW
For networks and servers, small and medium data For large data centres
centres, telecommunication

ECS Emergency Central Systems 52


INGENIO PLUS 30 3/1- AND 3/3-PHASE E8000 ECS 10-20 KVA
3-PHASE UPS 30-160 kVA/kW 3-PHASE INGENIO ECS 30-160 KVA
For small and medium data centres, networks and For emergency lighting, fire fighting and safety
servers, industrial controls and process automation, equipment according to EN 50171
medical equipment and building automation

STS 16-32 A 60
INGENIO MAX 34 1-PHASE RACKMOUNT STS
3-PHASE UPS 200-600 kVA/kW Rackmount Static Transfer Switches for networks and
For medium data centres, networks and servers, industrial servers, data centres, industrial controls and process
controls and process automation, medical equipment, automation
building automation

STS 100-3000 A 62
B9000 FXS 38 3-PHASE CENTRALISED STS
3-PHASE UPS 60-300 kVA Centralised Static Transfer Switches for networks and
Transformer based UPS for networks and servers, servers, data centres, industrial controls and process
industrial control and process automation, medical automation
equipment, building automation

GUARDIAN NET 66
B9600 FXS 42 Remote Diagnostics and Preventive Monitoring
3-PHASE UPS 400-800 KVA
Hi-power transformer based UPS for networks and
servers, industrial controls and process automation, INDUSTRIAL POWER SOLUTIONS 68
medical equipment and building automation For harsh industrial applications

INGENIO MAX XT 46 Borri Service 70


SCALABLE 3-PHASE UPS 750 kW - 2.1 MW
For large data centres, industrial controls and process
automation

www.borri.it
6 BORRI | WHO WE ARE

YOUR CRITICAL
POWER
SOLUTION
PARTNER.
The Borri Group has been developing and building
uninterruptible power systems since 1932 and is a global
provider of power electronics systems and solutions for harsh
industrial and demanding critical power requirements.

Borri's R&D vast expertise Based in Bibbiena, Italy


in all facets of firmware, power with over 15,000 m² production
electronics and mechanical design area, Borri operates across all five
provides innovative solutions for continents with subsidiaries in USA,
tomorrows problems in Industrial Canada, Germany, UAE, India and
and Critical Power applications. Malaysia.

The company prides itself on It has also established a


its first-class service and superior strong distributor network, able
engineering disciplines. To ensure to deliver on site support and
sustained quality, Borri manages technical guidance indicative of
all its processes in house from feed our own capabilities.
studies to design, production and
after sales service technology.

www.borri.it
BORRI | WHO WE ARE 7

Critical Power
Solutions
Designing and building mission
critical UPS’s 1- and 3-Phase
up to 21 MW.

Industrial Power
Solutions
Designing, engineering and
building customised AC and DC
power supply systems for harsh
industrial applications.

Service
Borri team of experts support
you to the highest standards
no matter where you are in the
world.

www.borri.it
8 UPS | CRITICAL POWER SOLUTION

UPS FOR COMPUTERS


AND PERIPHERALS,
DATA CENTRES,
NETWORKS AND
SERVERS.
from 450 VA to 21 MW

1-PHASE UPS & STS 3-PHASE UPS & STS

Giotto Galileo B8031FXS B8033FXS


Line interactive1-Phase UPS On-line 1-Phase UPS 3/1-Phase UPS 3/3-Phase UPS
from 450 to 2000 VA from 1000 to 3000 VA from 10 to 20 kVA from 10 to 20 kVA

Leonardo STS 16-32 Ingenio Compact Ingenio Plus


On-line 1-Phase UPS 1-Phase Static Transfer Switches 3-Phase UPS 3-Phase UPS
from 6 to 10 kVA 16 and 32 A from 10 to 20 kW from 30 to 160 kW

www.borri.it
UPS | CRITICAL POWER SOLUTION 9

Supplying both standalone and modular UPS, Borri provides the best
power protection solution whether your business is a small office
or a hyperscale data centre.

COMPUTER AND PERIPHERAL SMALL AND MEDIUM DATA CENTRE

NETWORK AND SERVER LARGE DATA CENTRE

DATA CENTRE UPS’S AND SYSTEMS

B9000FXS B9600FXS Ingenio MAX XT STS 300


Transformer 3-Phase UPS Transformer 3-Phase UPS Scalable high-power UPS 3-Phase Static Transfer Switches
from 60 to 300 kVA from 400 to 800 kVA from 750 kW to 2.1 MW from 100 to 3000 A

Ingenio MAX STS 300 UPSaver 3vo


3-Phase UPS 3-Phase Static Transfer Switches Modular high-power UPS
from 200 to 600 kW from 100 to 3000 A from 670 kW to 21 MW

www.borri.it
10 UPS | CRITICAL POWER SOLUTION

UPS FOR INDUSTRIAL


CONTROLS,
PROCESS AUTOMATION,
MEDICAL EQUIPMENT,
BUILDING AUTOMATION
AND EMERGENCY
SYSTEMS.
from 10 kW to 4.8 MW

3-PHASE UPS & STS

B8031FXS B8033FXS
3/1-Phase UPS 3/3-Phase UPS
from 10 to 20 kVA from 10 to 20 kVA

Ingenio Plus Ingenio MAX


3-Phase UPS 3-Phase UPS
from 30 to 160 kW from 200 to 600 kW

www.borri.it
UPS | CRITICAL POWER SOLUTION 11

Borri provides facility managers with resilient critical power solutions


across all their applications whether they be health care centres or
manufacturing facilities.

INDUSTRIAL CONTROLS MEDICAL EQUIPMENT


AND PROCESS AUTOMATION

BUILDING AUTOMATION EMERGENCY AND SAFETY SYSTEMS

ECS – EMERGENCY CENTRAL SYSTEMS

B9000FXS B9600FXS E8000 ECS


Transformer 3-Phase UPS Transformer 3-Phase UPS 3/1 - 3/3 - Phase ECS
from 60 to 300 kVA from 400 to 800 kVA from 10 to 20 kVA

Ingenio MAX XT STS 300 INGENIO ECS


Scalable high-power UPS 3-Phase Static Transfer Switches 3-Phase ECS
from 750 kW to 2.1 MW from 100 to 3000 A from 30 to 160 kVA

www.borri.it
12 1-PHASE UPS | 450 VA - 10 kVA

1-PHASE
UPS
from 450 VA to 10 kVA

www.borri.it
1-PHASE UPS | 450 VA - 10 kVA 13

Applications

Home office Computers Network Small


& Peripherals & Server data centre

User-friendly Convertible design


Easy installation Online UPS's can be used
and setup for immediate in both tower and rack
use. Intuitive LCD display configurations.
Providing easy-to-read
UPS status and power
information.

Suitable for a variety of Small-Office and Home-Office applications, Borri 1-phase UPS's Giotto,
Galileo and Leonardo have been designed to prevent power interferences and to keep your
small and medium equipment running.

www.borri.it
14 GIOT TO | 450 VA - 2000 VA

GIOTTO Line interactive 1-Phase UPS


ideal for home and small office,
from 450 VA to 2000 VA computers and peripherals.

Features and benefits


User-friendly UPS ensuring compact Audible alarm alerts upon utility
protection for a wide range of power and UPS status change.
needs:
Easy User-replaceable battery.
- Best power protection for PC from
450 to 850 VA with one output AVR technology stabilizing output
receptacle (IEC 320-C13) and voltage to protect your electronics
one Schuko. over a wide range of mains quality
- Advanced power protection issues.
from 1000 to 2000 VA with four
output receptacles (IEC 320- Advanced battery management
C13) and one Schuko for high extending battery life.
performance PC and peripherals.
Internet Modem / LAN protection
Instantaneous battery back-up via RJ-11/45 plug.
power and electrical interference
protection. USB communication port providing
UPS managements.
Plug and Play installation easy to set
up also for first-time users. Cold start for powering loads when
mains are not available.
Compact and noise-free running
to be placed anywhere at home or Borri Power Guardian user-friendly
office. UPS management software free
downloadable at www.borri.it/
Energy efficient ensuring lowest download (for more info see
impact on energy costs. p.20/21).

Intuitive LCD display provides


easy-to-read UPS status and power
information.

Back up time with internal batteries


0' 1' 2' 3' 4' 5' 6' 7'

2000 VA

1500 VA

1000 VA

850 VA

650 VA

450 VA

Internal battery 50% load

www.borri.it
GIOT TO | 450 VA - 2000 VA 15

GIOTTO technical data


Rating (VA) 450 650 850 1000 1500 2000
Nominal Power (W) 270 380 500 600 900 1200
UPS dimensions WxDxH (mm) 100x292x140 148x315x198
UPS weight (kg) 4 5 5.5 9 10.5 11.8
Input
Connection type IEC 320-C14
Nominal voltage 230 Vac 1-phase
Voltage range 160 to 290 Vac
Frequency and range 50/60 Hz, 45 to 65 Hz
Output
Connection type 1 IEC 320-C13 and 1 Schuko 4 IEC 320-C13 and 1 Schuko
Nominal voltage 230 Vac 1-phase
Frequency 50/60 Hz
Wave form Simulated sine wave
Battery
50% load 5 5 5 6 5 4
Autonomy time (min.) ◊
100% load 3 3 3 3 3 2
Connectivity and function extensions
Front panel LCD, ON/OFF button
Included: USB
Communication Compatible platforms: Windows, Linux, Mac
Environmental
Operating temperature range 0°C to +40°C
Altitude (AMSL) < 1000 m without power reduction, > 1000 m with reduction of 0.5% per 100 m
Audible noise at 1 m (dBA) < 40
Standards and certifications
Quality assurance, environment,
ISO 9001:2015, ISO 14001:2015, BS OHSAS 18001:2007
health and safety
Safety IEC/EN 62040-1
EMC IEC/EN 62040-2
Marking CE
◊ Measurement conditions: optimised parameters, fully charged battery, 0.6 PF

www.borri.it
16 GALILEO | 1000 VA - 3000 VA

GALILEO On-line 1-Phase UPS with


Tower and Rack/Tower convertible
from 1000 VA to 3000 VA design ideal for small and medium
businesses, networks and servers.

Intuitive LCD display providing easy- Borri Power Guardian user-friendly


to-read UPS status and power UPS management software with
information. alerts upon main power failures and
system shutdown notification via
Audible alarm alerts upon utility SMS and email, free downloadable
power and UPS status change. at www.borri.it/download (for more
info see p.20/21).
Smart cooling system ensuring
further energy savings.
Main options
Programmable switched outlet group
SNMP card to send UPS status to
for setting load priorities.
BMS’s by Ethernet connection and
SNMP or ModBus over IP protocol
Active harmonic power quality
to monitor UPS status by any internet
control ensuring up to 0.99 input
browser from workstations and to
PF and THDi<3% for maximum
receive SMS or e-mail alerts from
compatibility with sources.
Features and benefits the UPS on any portable device.
Automatic self test and advanced
On-line double conversion UPS from Contact relay card to send UPS
battery management maximizing
1000 to 3000 VA, Tower and 2U status to PLC’s, SCADA’s or AS400’s
battery performance and extending
Rack/Tower from three to six output by voltage free SPDT contacts.
battery life.
receptacles (IEC 320-C13) and one
or two Schuko. Battery extension box allowing
Remote power off for immediate
additional autonomy time to be
UPS shutdown in case of emergency.
Rack/Tower convertible design quickly added.
to protect your investment when USB communication port providing
migrating from tower to rack-mount Additional battery charger for
UPS management.
environment. Both UPS and display external battery box.
panel can be rotated. One slot auto-sensing
Rail kit Rack/Tower.
communication cards.
Easy installation and set up,
user-replaceable and upgradable Rack PDU with external sockets and
Cold start for powering loads when
battery. manual bypass switch.
mains are not available.

Back up time for Rack/Tower UPS Back up time for Tower UPS
0' 10' 20' 30' 40' 50' 60' 70' 0' 10' 20' 30' 40' 50' 60' 70'

3 kVA 3 kVA

2 kVA 2 kVA

1 kVA 1 kVA

Internal battery N°1 Battery box N°2 Battery box Internal battery N°1 Battery box N°2 Battery box

www.borri.it
GALILEO | 1000 VA - 3000 VA 17

GALILEO technical data


UPS Type T* T* T* RT (2U) ** RT (2U) ** RT (2U) **
Rating (VA) 1000 2000 3000 1000 2000 3000
Nominal Power (W) 900 1800 2700 900 1800 2700
UPS dimensions WxDxH (mm) 144x367x236 151x444x322 189x444x322 440x390x88 440x475x88 440x600x88
UPS weight (kg) 11.2 18.8 24.9 12.0 17.0 26.5
Input
Connection type IEC 320-C14 IEC 320-C20 IEC 320-C14 IEC 320-C20
Nominal voltage 230 Vac 1-phase
Voltage range 195 to 260 Vac
Frequency and range 50/60 Hz, 45 to 65 Hz
Power factor 0.98 0.99
Current distortion (THDi) <3%
Output
3 IEC 320-C13 3 IEC 320-C13 6 IEC 320-C13
Connection type 3 IEC 320-C13 6 IEC 320-C13
1 Schuko 2 Schuko 2 Schuko
Nominal voltage 230 Vac +/-1% 1-phase
Frequency 50/60 Hz
Power factor Up to 0.9, without power derating
Overload capability 105% continuous, 120% for 30 seconds, 150% for 10 seconds, >150% transfer to bypass
Mode of operation On-line, Eco mode
Battery

Autonomy time 50% load 12 13 15 12 13 15



internal battery (min.) 100% load 6 6 6 6 6 6
Connectivity and function extensions
Front panel Display LCD, status LED, function keys
Included: USB, EPO, RS232.
Communication Optional: dry contact card, SNMP card.
Compatible platforms: Windows, Linux, Mac
Environmental
Operating temperature range 0°C to +40°C
Altitude (AMSL) < 1000 m without power reduction, > 1000 m with reduction of 0.5% per 100 m
Audible noise at 1 m (dBA) < 50
Standards and certifications
Quality assurance, environment,
ISO 9001:2015, ISO 14001:2015, BS OHSAS 18001:2007
health and safety
Safety IEC/EN 62040-1
EMC IEC/EN 62040-2
Marking CE
*Tower **Rack/Tower ◊ Measurement conditions: optimised parameters, fully charged battery, 0.7 PF
GALILEO T 1 kVA

GALILEO T 2 kVA

GALILEO T 3 kVA

90°

GALILEO RT 2/3 kVA GALILEO RT 1 kVA

www.borri.it
18 LEONARDO | 6 kVA - 10 kVA

LEONARDO High-power on-line


1-phase UPS with Rack/Tower
from 6 kVA to 10 kVA convertible design, ideal for networks
and servers, small data centres.

Features and benefits


On-line double conversion UPS Automatic self test and advanced
from 6 to 10 kVA, Tower and 2U or battery management maximizing
3U Rack/Tower. battery performance and extending
battery life.
Parallel redundant configuration
maximizing the availability. Remote emergency power off to
guarantee your piece of mind in
Rack/Tower convertible design critical applications.
to protect your investment when
migrating from tower to rack-mount Internal manual bypass for safe and
environment. Both UPS and display easy maintenance.
panel can be rotated.
RS232 communication port
Easy installation and set up, user providing UPS management.
replaceable and upgradable
battery. Two slots auto-sensing
communication cards.
Intuitive LCD display providing
easy-to-read UPS status and power Cold start for powering loads when
information. mains are not available.

Audible alarm alerts upon utility Borri Power Guardian user-friendly


power and UPS status change. UPS management software with
alerts upon main power failures and
Smart cooling system ensuring system shutdown notification via
further energy savings. SMS and email, free downloadable
at www.borri.it/download (for
Main options Active harmonic power quality more info see p.20/21).
SNMP card to send UPS status to control ensuring 0.99 input PF
BMS’s by Ethernet connection and and THDi<3% for maximum
SNMP or ModBus over IP protocol compatibility with sources.
to monitor UPS status by any internet
browser from workstations and to
receive SMS or e-mail alerts from
the UPS on any portable device. Back up time for Back up time for
Rack/Tower UPS Tower UPS
Contact relay card to send UPS
status to PLC’s, SCADA’s or AS400’s 0' 10' 20' 30' 40' 50' 60' 0' 10' 20' 30' 40' 50' 60'
by voltage free SPDT contacts.
10 kVA

10 kVA

Battery extension box allowing


additional autonomy time to be
quickly added.
6 kVA

6 kVA

Additional battery charger for


external battery box.
COMPACT

Parallel kit.
6 kVA

Rail kit Rack/Tower.

Rack PDU with external sockets and Internal battery N°1 Battery box Internal battery N°1 Battery box
manual bypass switch. N°2 Battery box

www.borri.it
LEONARDO | 6 kVA - 10 kVA 19

LEONARDO technical data


UPS Type T* T* RT (2U) *** RT (4U) ** RT (3U) ***
Rating (kVA) 6 10 6 6 10
Nominal Power (kW) 5.4 9 5.4 5.4 9
UPS dimensions WxDxH (mm) 290x645x748 290x645x748 440x680x88 440x680x176 440x680x132
UPS weight (kg) 86 96 24 52 26
Input
Connection type Hardwired 2w (rectifier), 2w (bypass) Hardwired 2w
Nominal voltage 230 Vac 1-phase
Voltage range 160 to 280 Vac
Frequency and range 50/60 Hz, 45 to 65 Hz
Power factor 0.99
Current distortion (THDi) <6%
Output
Connection type Hardwired 2w
Nominal voltage 230 Vac +/-1% 1-phase
Frequency 50/60 Hz
Power factor Up to 0.9, without power derating
Overload capability 104% continuous, 150% for 160 seconds, >150% transfer to bypass
Mode of operation On-line, Eco mode
Classification by IEC/EN 62040-3 VFI-SS-11
Battery

Autonomy time 50% load 25 17 external battery 15 external battery
internal battery (min.) 100% load 9 6 external battery 6 external battery
Connectivity and function extensions
Front panel Display LCD, status LED, function keys
Included: USB, RS232 card, EPO.
Communication Optional: dry contact card, SNMP card, RS485 card.
Compatible platforms: Windows, Linux, Mac
Environmental
Operating temperature range 0°C to +40°C
Altitude (AMSL) < 1000 m without power reduction, > 1000 m with reduction of 0.5% per 100 m
Audible noise at 1 m (dBA) < 50
Standards and certifications
Quality assurance, environment,
ISO 9001:2015, ISO 14001:2015, BS OHSAS 18001:2007
health and safety
Safety IEC/EN 62040-1
EMC IEC/EN 62040-2
Marking CE
*Tower with internal battery **Rack/Tower with internal battery ***Rack/Tower without internal battery
◊ Measurement conditions: optimised parameters, fully charged battery, 0.7 PF
LEONARDO RT (4U) 6 kVA
LEONARDO T 6/10 kVA

LEONARDO RT (3U) 10 kVA

LEONARDO RT (2U) 6 kVA

www.borri.it
20 POWER GUARDIAN | 1-PHASE UPS MONITORING SOFTWARE

POWER GUARDIAN
1-PH UPS MONITORING
SOFTWARE
available for MAC and MICROSOFT
WINDOWS

www.borri.it
POWER GUARDIAN | 1-PHASE UPS MONITORING SOFTWARE 21

Borri Power Guardian is a free user-friendly UPS software,


providing monitoring of the UPS status and automatic safe
system shutdown during power outages.

Features and benefits

Fast, easy installation and


configuration via USB or RS232
even for first-time users.

Automatic orderly application and


system shutdown.

Preventing potential data


corruption and hardware damage.

Alerts on main power failures and


system shutdowns notification via
SMS and email.

Automatic self-test of UPS and


battery status ensuring early
detection of anomalies.

UPS parameters and power


status at a glance. It summarizes
graphically and numerically
power problems such as blackouts
or electrical noise over time and
UPS information such as input
and output voltage, frequency,
temperature, loads and battery
capacity.

Customised settings for tailor-


made solutions.

Available for MAC and Microsoft


Windows operating systems
(complete list at www.borri.it/
download).

Download Borri Power Guardian


free software at www.borri.it/
download.

www.borri.it
22 B8031FXS - B8033FXS | 10 kVA - 20 kVA

UPS 3/1-PHASE and 3/3-PHASE

B8031FXS
B8033FXS
from 10 kVA to 20 kVA

www.borri.it
B8031FXS - B8033FXS | 10 kVA - 20 kVA 23

Applications

Network Industrial Medical Building


& Server controls & process equipment automation
automation

Robust and compact Easy to install


Full IGBT technology and maintain
providing smooth Removable power modules
sinusoidal input current Low running costs and simple handling
cuts all upstream oversizing for low installation and mean
High efficiency and ECO
costs. time to repair.
mode reduce overall
power losses and thus
energy costs.

Robust, customisable and easy-to-maintain UPS, available as either 3-phase in/1-phase out
or 3-phase in/3-phase out. B8031 FXS and B8033 FXS series is suitable for server rooms,
IT equipment, industrial controls, medical equipment and process automation.

www.borri.it
24 B8031FXS - B8033FXS | 10 kVA- 20 kVA

B8031FXS - B8033FXS: featuring extremely small dimensions


and one of the smallest footprint in its range.

Features and benefits


High double conversion efficiency High power battery charger, suiting
and ECO mode for low running long autonomy applications.
costs and environmental impact.
Dual DSP plus microcontroller logics
Transformer free design for light for top performance and reliability.
small size layout.
CAN-bus based distributed parallel
Removable power modules control ensuring high load sharing
architecture and built-in diagnostics accuracy and no single point of
for easy maintenance and very low failure.
MTTR.
Comprehensive set of
Hot connection/disconnection communication options for total
of parallel units for easy system remote monitoring of equipment
resizing. operation.

Full IGBT technology and electronic Included bypass contactor for


PFC, ensuring 0.99 input PF and complete backfeed protection and
low THDi for maximum upstream operators’ safety without additional
sources compatibility. installation costs.

Wide range of configurations with Fully compliant with all international


internal batteries for low TCO product standards for maximum
compact solutions. quality guarantee.

Back up time wth internal batteries


0' 5' 10' 15' 20' 25' 30' 35'

20 kVA

15 kVA

10 kVA

Main options
Isolation transformer. Battery fuse switch wall-mounted Input terminals for remote EPO,
box. external manual bypass auxiliary
Transformers/autotransformers for contact, diesel mode.
voltage adjustment. Associated battery cabinets for long
autonomy times. Separate bypass input for B8033FXS.
Battery voltage temperature
compensation. Parallel redundant up to 6 units for
system redundancy
External maintenance bypass wall-
mounted box. Load-sync option.

www.borri.it
B8031FXS - B8033FXS | 10 kVA - 20 kVA 25

B8031FXS - B8033FXS technical data


Rating (kVA) 10 15 20
Nominal Power (kW) 9 13.5 18
UPS dimensions WxDxH (mm) 450x640x1200
UPS weight (kg) 100 110 110
UPS weight with internal battery (kg) 247 257 257
External battery module dimensions 500x640x1200
WxDxH (mm)
Battery configuration Internal or external, 360 to 372 cells, VRLA (other options)
Max autonomy with int. battery 70%
32 19 12
load (min)
Input B8031FXS (10-15-20 kVA) B8033 FXS (10-15-20 kVA)
Connection type Hardwired 4w (rectifier), 2w (bypass) Hardwired 4w
400 Vac 3-phase with neutral (rectifier) 400 Vac 3-phase with neutral (rectifier)
Nominal voltage
220/230/240 Vac 1-phase (bypass) 380/400/415 Vac 3-phase with neutral (bypass)
Voltage tolerance -20%, +15% (rectifier); ±10% (bypass)
Frequency and range 50/60 Hz, 45 to 65 Hz
Power factor 0.99
Current distortion (THDi) <4%
Output B8031FXS (10-15-20 kVA) B8033 FXS (10-15-20 kVA)
Connection type Hardwired 2w Hardwired 4w
Nominal voltage 220/230/240 Vac 1-phase 380/400/415 Vac 3-phase with neutral
Frequency 50/60 Hz
Voltage regulation Static: ±1% ; Dynamic: IEC/EN 62040-3 Class 1
Power factor Up to 0.9, without power derating
Overload capacity Inverter: 125% for 10 min, 150% for 30 s ; Bypass: 150% continuous, 1000% for 1 cycle
Efficiency (AC/AC)* Up to 98%
Classification by IEC/EN 62040-3 VFI-SS-11
Connectivity and function extensions
Front panel Graphic display, mimic LED panel and keyboard, local EPO
Included: serial RS232 and USB; terminal block for battery breaker auxiliary contact.
Optional: input terminal block (remote emergency power off,
Remote communication external maintenance bypass circuit breaker aux. cont., diesel mode aux. cont.); SNMP adapter (Ethernet),
Web interface (Ethernet), ModBus-TCP/IP (Ethernet), ModBus-RTU (RS485), from ModBus-RTU to PROFIBUS DP adapter;
SPDT contact relay board; remote system monitoring panel; UPS managing and server shutdown software
Isolation transformer; transformers/autotransformers for voltage adjustment;
Optional function extensions external maintenance bypass; custom battery cabinets; wall-mounted battery fuse switch box;
battery thermal probe; parallel kit, load-sync for single UPS; other options on request
System
Protection degree IP 20
Colour RAL 7016
Installation layout 10 cm wall-gap, side by side installation allowed
Accessibilty Front and top access, bottom cable entry
*according to IEC/EN 62040-3

Other features
Environmental
UPS operating temperature range 0°C to +40°C
UPS storage temperature range -10°C to +70°C
Altitude (AMSL) < 1000 m without power reduction, > 1000 m with reduction of 0.5% per 100 m
Audible noise at 1 m (dBA) < 52
Standards and certifications
Quality assurance, environment,
ISO 9001:2015, ISO 14001:2015, BS OHSAS 18001:2007
health and safety
Safety IEC/EN 62040-1
EMC IEC/EN 62040-2
Environment aspects IEC/EN 62040-4
Test and performance IEC/EN 62040-3
Protection degree IEC 60529
Marking CE

www.borri.it
26 INGENIO COMPACT | 10 kW - 20 kW

UPS 3-PHASE

INGENIO
COMPACT
from 10 kW to 20 kW

www.borri.it
INGENIO COMPACT | 10 kW - 20 kW 27

Applications

Small Medium Network Telecommunication


data centre data centre & Server

Innovative design Power factor 1


User-friendly design Full rated output power
with built-in LCD touch guaranteeing maximum real
screen for fast installation Wide battery range power and optimal
and monitoring. UPS sizing.
Internal and external
batteries for low TCO
compact solutions.

One of the most compact and easy to use solutions on the market, designed for critical power
applications such as networks and servers, small and medium data centres, telecommunication.
The UPS is available in the 10-20 kW range with online double conversion technology
and parallel redundant configuration.

www.borri.it
28 INGENIO COMPACT | 10 kW - 20 kW

Ingenio Compact: transformer free, high efficiency, compact and


easy to install and use.

Features and benefits


On-line double conversion mode Wide range of configurations with
for total load protection. internal and external batteries for
low TCO compact solutions.
ECO mode for low running costs
and environmental impact. Innovative design allows for fast
installation.
Full rated output power (pf=1),
ensuring optimal UPS sizing and Removable tray design for easy
utilization. battery maintenance.

Transformer free design for light Comprehensive set of


small size layout. communication options for total
remote monitoring of equipment
Full IGBT technology and electronic operation.
PFC, ensuring 0.99 input PF and
low THDi for maximum upstream Fully compliant with all international
sources compatibility. product standards for maximum
quality guarantee.
Wide input voltage range to save
battery life.

Back up time
with internal batteries
0' 5' 10' 15' 20'

20 kW

15 kW

10 kW

Main options
Isolation transformer. External battery cabinets for long
autonomy times.
Transformers/autotransformers for
voltage adjustment. Parallel redundant up to 6 units for
system redundancy.
Battery voltage temperature
compensation. Common battery.

External maintenance bypass wall-


mounted box.

www.borri.it
INGENIO COMPACT | 10 kW - 20 kW 29

INGENIO COMPACT technical data


Rating (kVA) 10 15 20
Nominal Power (kW) 10 15 20
UPS dimensions WxDxH (mm) 440x800x800
UPS weight (kg) 75 76 76
UPS weight with internal battery (kg) 150 165 165
External battery module dimensions
550x650x1200
WxDxH (mm)
Internal (standard): 180 cells; external:
Battery configuration Internal (standard): 216 cells; external: 192/240 cells
156/240 cells
Input
Connection type Hardwired 4w
Nominal voltage 400 Vac 3-phase with neutral
Voltage tolerance -20%, +15% (rectifier); ±10% (bypass)
Frequency and range 50/60 Hz, 40 to 70 Hz
Power factor 0.99
Current distortion (THDi) <3%
Output
Connection type Hardwired 4w
Nominal voltage 380/400/415 Vac 3-phase with neutral
Frequency 50/60 Hz
Power factor Up to 1, without power derating
Overload capacity 110% for 60 min, 125% for 10 min, 150% for 1 min
Efficiency (AC/AC)* Up to 98%
Classification by IEC/EN 62040-3 VFI-SS-11
Connectivity and function extensions
Front panel Touch screen display
Included: serial RS232; backfeed protection monitoring contact, remote EPO contact.
Remote communication Optional: 2 slots for SNMP adapter, ModBus-RTU, contact relay card
Isolation transformer; transformers/autotransformers for voltage adjustment;
Optional function extensions external maintenance bypass; custom battery cabinets; wall-mounted battery fuse switch box;
battery thermal probe; parallel kit; other options on request
System
Protection degree IP 20
Colour RAL 9005
Installation layout 30 cm wall-gap
Accessibilty Positioning casters; bottom cable entry
*according to IEC/EN 62040-3

Other features
Environmental
UPS operating temperature range 0°C to +40°C
UPS storage temperature range -10°C to +70°C
Altitude (AMSL) < 1000 m without power reduction, > 1000 m with reduction of 0.5% per 100 m
Audible noise at 1 m (dBA) < 52
Standards and certifications
Quality assurance, environment,
ISO 9001:2015, ISO 14001:2015, BS OHSAS 18001:2007
health and safety
Safety IEC/EN 62040-1
EMC IEC/EN 62040-2
Environment aspects IEC/EN 62040-4
Test and performance IEC/EN 62040-3
Protection degree IEC 60529
Marking CE

www.borri.it
30 INGENIO PLUS | 30 kW - 160 kW

UPS 3-PHASE

INGENIO
PLUS
from 30 kW to 160 kW

www.borri.it
INGENIO PLUS | 30 kW - 160 kW 31

Applications

Small Medium Network Industrial Medical Building


data centre data centre & Server controls & process equipment automation
automation

Power factor 1 Compact footprint


No costs related to electrical Efficient compact UPS
infrastructure oversizing and with transformer free
power factor correction. Continuous savings design.
Patented Green Conversion
technology provides high
efficiency and extended life
on UPS critical components
and batteries.

The ideal power protection solutions for a range of critical applications, including networking and small to
medium data centres, health, finance, industrial processing, building and transportation.
Featuring Green Conversion patented technology, Ingenio Plus provides high efficiency
even at light loads.

www.borri.it
32 INGENIO PLUS | 30 kW - 160 kW

Ingenio Plus: compact and very high efficient solution perfect


for supplying reliable uninterrupted quality power to all critical
applications.
Features and benefits
Green Conversion technology, high Dynamic Charging Mode (DCM)
efficiency even at light load and the for maximum versatility in long
lowest TCO in its category. autonomy and low charging time
applications.
Full rated output power (pf=1),
ensuring optimal UPS sizing and Green Conversion Battery Care
utilization. (GCBC), for extended battery
service life.
Transformer free design for
compact, light and sustainable Comprehensive set of
systems. communication options for total
remote monitoring of equipment
Full IGBT technology and electronic operation.
PFC, ensuring 0.99 input PF and
THDi<3% for maximum upstream Fully compliant with all international
sources compatibility. product standards for maximum
quality guarantee.
Internal battery configurations up
to 80 kVA for less floor space and Backfeed protection contact.
maximum flexibility.
Lithium Battery compatible on
selected models.

Back up time
with internal batteries
0' 5' 10' 15'

80 kVA

60 kVA

40 kVA

30 kVA
*Optional touch screen display (on 60-160 kW UPS)

Main options
Isolation transformer. Battery fuse switch wall-mounted Common battery (on 60-160 kVA
box. range).
Transformers/autotransformers for
isolation or voltage adjustment. Battery cabinets for long autonomy Backfeed protection trip coil.
times.
Battery voltage temperature Separate rectifier and bypass input
compensation. Parallel redundant up to 8 units for for INGENIO PLUS 30-40 kVA.
system redundancy.
External maintenance bypass wall- Colour touch screen 7" display on
mounted box. Load-sync option. 60-160 kVA UPS (*)

www.borri.it
INGENIO PLUS | 30 kW - 160 kW 33

INGENIO PLUS technical data


Rating (kVA) 30 40 60 80 100 125 160
Nominal Power (kW) 30 40 60 80 100 125 160
UPS dimensions WxDxH (mm) 465x650x1230 560x940x1500 560x940x1800
UPS weight (kg) 120 140 190 215 320 360 380
UPS weight with internal battery (kg) 365 385 770 785 - - -
Battery configuration Internal or external, 360 to 372 cells, VRLA (other options) External 360 to 372 cells, VRLA (other options)
Max autonomy with int. battery 70%
11 7 12 8 - - -
load (min)
Input
Connection type Hardwired 4w Hardwired 4w (rectifier), 4w (bypass)
Nominal voltage 400 Vac 3-phase with neutral (rectifier) ; 380/400/415 Vac 3-phase with neutral (bypass)
Voltage tolerance -20%, +15% (rectifier); ±10% (bypass)
Frequency and range 50/60 Hz, 45 to 65 Hz
Power factor >0.99
Current distortion (THDi) <3%
Output
Connection type Hardwired 4w
Nominal voltage 380/400/415 Vac 3-phase with neutral
Frequency 50/60 Hz
Voltage regulation Static: ±1%; Dynamic: IEC/EN 62040-3 Class 1
Power factor Up to 1, without power derating
Overload capacity* Inverter: 110% for 10 min, 125% for 5 min, 150% for 30 s ; Bypass: 150% continuous, 1000% for 1 cycle
Efficiency (AC/AC)** Up to 99%
Classification by IEC/EN 62040-3 VFI-SS-11
Connectivity and function extensions
Front panel Graphic display, mimic LED panel and keyboard, local EPO
Included:(30 to 160 kVA): backfeed protection monitoring contact.
Included (60 to 160 kVA): serial RS232 and USB; input terminal block (remote emergency power off,
battery circuit breaker aux. cont. external maintenance bypass circuit breaker aux. cont., diesel mode aux. cont.).
Remote communication Optional: SNMP adapter (Ethernet), Web interface (Ethernet), ModBus-TCP/IP (Ethernet), ModBus-RTU (RS485),
from ModBus-RTU to PROFIBUS DP adapter; SPDT contact relay board; remote system monitoring panel;
UPS managing and server shutdown software
Isolation transformer; transformers/autotransformers for voltage adjustment;
Optional function extensions external maintenance bypass; custom battery cabinets; wall-mounted battery fuse switch box;
battery thermal probe; parallel kit, load-sync for single UPS and load-sync box (2 UPS systems); other options on request
System
Protection degree IP 20
Colour RAL 9005
10 cm wall-gap, side by side
Installation layout Wall and side by side installation allowed, 80 cm side clearance (with internal battery)
installation allowed
Front and top access,bottom Front and top access, side access (with Front access, side access (with internal battery)
Accessibilty internal battery) bottom cable entry bottom cable entry
cable entry
*conditions apply **according to IEC/EN 62040-3

Other features
Environmental
UPS operating temperature range 0°C to +40°C
UPS storage temperature range -10°C to +70°C
Altitude (AMSL) < 1000 m without power reduction, > 1000 m with reduction of 0.5% per 100 m
Audible noise at 1 m (dBA) < 60
Standards and certifications
Quality assurance, environment,
ISO 9001:2015, ISO 14001:2015, BS OHSAS 18001:2007
health and safety
Safety IEC/EN 62040-1
EMC IEC/EN 62040-2
Environment aspects IEC/EN 62040-4
Test and performance IEC/EN 62040-3
Protection degree IEC 60529
Marking CE

www.borri.it
34 INGENIO MAX | 200 kW - 600 kW

UPS 3-PHASE

INGENIO
MAX
from 200 kW to 600 kW

www.borri.it
INGENIO MAX | 200 kW - 600 kW 35

Applications

Medium Large Network Industrial Medical Building


data centre data centre & Server controls & process equipment automation
automation

Very High Efficiency Reduced TCO


Patented 3-level Flexible system
Green Conversion up to 4 MW in a
technology. Compact footprint minimum space.
Some of the most compact
footprints on the market
and full front access.

Low Total Cost of Ownership, high efficiency and compact solution for supplying reliable
uninterrupted quality power to all critical applications in networking and medium to large data
centre, health, finance, industrial processing, building and transportation markets and for TLC.

www.borri.it
36 INGENIO MAX | 200 kW - 600 kW

Ingenio Max: highest online efficiency in its class for a wide range
of high power critical applications.

Features and benefits


Three level Green Conversion, for Green Conversion Battery Care
enhanced system efficiency, very (GCBC) for extended battery
low noise and the lowest TCO in its service life.
category.
Increased power density, for
Full output power rating (pf=1), unmatched floorspace saving.
ensuring optimal UPS sizing and
high flexibility for all types of loads. Comprehensive set of
communication options for total
On-line double conversion remote monitoring of equipment
transformer-free design for low PUE operation.
and TCO.
Fully compliant with international
Full IGBT technology and electronic product standards for maximum
PFC,ensuring 0.99 input PF and quality guarantee.
THDi<3% for maximum upstream
sources compatibility. Colour touch screen 10" display for
easy monitoring and control.
Dynamic Charging Mode (DCM)
for maximum versatility in long Lithium Battery compatible.
autonomy and low charging time
applications.

Green Conversion Battery Care vs conventional


float charge enhanced battery service life
100%

80% Battery end of life


Battery capacity %

60%

40%
Without With
Green Conversion Green Conversion
20%

0 2 4 6 8 10
Battery life (years)

Main options
Transformers/autotransformers for Battery fuse switch wall-mounted Load-sync option.
isolation or voltage adjustment. box.
Common battery on selected models.
Battery voltage temperature Battery cabinets for long autonomy
compensation. times. Backfeed protection trip coil.

External maintenance bypass wall- Parallel up to 8 units for system


mounted box. redundancy.

www.borri.it
INGENIO MAX | 200 kW - 600 kW 37

INGENIO MAX technical data


Rating (kVA) 200 250 300 400 500 600
Nominal Power (kW) 200 250 300 400 500 600
UPS dimensions WxDxH (mm) 880x970x1978 1430x970x1978 1630x970x1978
UPS weight (kg) 530 745 675 1080 1250 1400
Battery configuration External 360 to 372 cells, VRLA (other options)
Input
Connection type Hardwired 4w (rectifier), 4w (bypass)
Nominal voltage 400 Vac 3-phase with neutral (rectifier); 380/400/415 Vac 3-phase with neutral (bypass)
Voltage tolerance -20%, +15% (rectifier); ±10% (bypass)
Frequency and range 50/60 Hz, 45 to 65 Hz
Power factor >0.99
Current distortion (THDi) <3%
Output
Connection type Hardwired 4w
Nominal voltage 380/400/415 Vac 3-phase with neutral
Frequency 50/60 Hz
Voltage regulation Static: ±1%; Dynamic: IEC/EN 62040-3 Class 1
Power factor Up to 1, without power derating
Overload capacity Inverter: 110% for 10 min, 125% for 5 min, 150% for 30 s; Bypass: 150% continuous, 1000% for 1 cycle
Efficiency (AC/AC)* Up to 99%
Classification by IEC/EN 62040-3 VFI-SS-11
Connectivity and function extensions
Front panel 10” colour touch screen display, 1024x600 pixels
Included: serial RS232 and USB, backfeed protection monitoring contact,
input terminal block (remote emergency power off, battery circuit breaker aux. cont.,
external maintenance bypass circuit breaker aux. cont., diesel mode aux. cont.,
Remote communication external output circuit breaker aux. cont., remote transfer to bypass mode).
Optional: SNMP adapter (Ethernet), Web interface (Ethernet), ModBus-TCP/IP (Ethernet), ModBus-RTU (RS485),
from ModBus-RTU to PROFIBUS DP adapter; SPDT contact relay board;
remote system monitoring panel; UPS managing and server shutdown software
Common battery; central bypass; cold start; Input /Output/Bypass isolation transformer;
other I/O voltages 480/690 Vac with autotransformers; external maintenance bypass; battery fuse switch box; custom battery
Optional features cabinets; battery thermal probe; parallel kit; load-sync for single UPS and load-sync box (3 UPS systems); top cable entry;
backfeed tripping coil for bypass disconnector; other options on request
System
Internal manual bypass Included as standard
Protection degree IP 20
Colour RAL 9005
Installation layout Wall, back to back and side by side installation allowed
Accessibilty Front access, bottom cable entry
*according to IEC/EN 62040-3

Other features
Environmental
Operating temperature range 0°C to +40°C
Storage temperature range -10°C to +70°C
Altitude (AMSL) < 1000 m without power reduction, > 1000 m with reduction of 0.5% per 100 m
Audible noise at 1 m (dBA) < 65 < 72 < 80
Standards and certifications
Quality assurance, environment,
ISO 9001:2015, ISO 14001:2015, BS OHSAS 18001:2007
health and safety
Safety IEC/EN 62040-1
EMC IEC/EN 62040-2
Environment aspects IEC/EN 62040-4
Test and performance IEC/EN 62040-3
Protection degree IEC 60529
Marking CE

www.borri.it
38 B9000FXS | 60 kVA - 300 kVA

UPS 3-PHASE

B9000FXS
from 60 kVA to 300 kVA

www.borri.it
B9000FXS | 60 kVA - 300 kVA 39

Applications

Small Medium Network Industrial Medical Building


data centre data centre & Server controls & process equipment automation
automation

Rugged design and Transformer


high reliability based design
Customisable UPS for Reliable design with output
specific process industry Minimum isolation transformer for
applications. maintenance costs DC/AC galvanic protection.
Full front accessibility to
all components and high
material quality extremely
reduce servicing.

Transformer-based UPS designed for safety and emergency systems, process control devices
and machine tooling, critical infrastructures, medical equipment, small and medium data centres
monolithic power protection.

www.borri.it
40 B9000FXS | 60 kVA - 300 kVA

B9000FXS: reliable, rugged transformer based power solution.

Features and benefits


Built-in inverter transformer for Smart parallel management in
DC/AC galvanic protection of load sharing, load synchronization
industrial type loads. of single UPS systems and load
synchronization of two paralleled
Full IGBT technology and electronic systems for optimum protection.
PFC, ensuring 0.99 input PF and
THDi<3% for maximum upstream Dual DSP plus microcontroller logics
sources compatibility. for top performance and reliability.

Front access to all critical CAN-bus based distributed parallel


components for easy maintenance. control ensuring high load sharing
accuracy and no single point of
Hot connection/disconnection failure in parallel systems.
of parallel units for easy system
resizing. Comprehensive set of
communication options for total
Accurate battery management remote monitoring of equipment
providing ripple current operation.
minimization charge current/
voltage control as per batteries Fully compliant with all international
manufacturers’ specifications and product standards for maximum
automatic/manual battery test for quality guarantee.
maximum battery expected life
preservation.

Dynamic Charging Mode (DCM)


for maximum versatility in long
autonomy and low charging time
applications.

Dynamic Charging BYPASS


Mode (DCM)

The battery charging


MAINS OUTPUT
current can be set above
the nominal, up to the DCM
limit, in order to manage
high capacity battery
packs. The extra charging
power is fed to the battery,
as long as the load does
not requires it. This is a
firmware enabled feature.

Main options
Backfeed protection bypass Battery voltage temperature Associated battery cabinets for long
contactor. compensation. autonomy times.

Bypass isolation transformer. External maintenance bypass wall- Parallel redundant up to 6 units or
mounted box. system redundancy.
Transformers/autotransformers for
voltage adjustment. Battery fuse switch wall-mounted Load-sync option.
box.
Top cable entry.

www.borri.it
B9000FXS | 60 kVA - 300 kVA 41

B9000FXS technical data


Rating (kVA) 60 80 100 125 160 200 250 300
Nominal Power (kW) 54 72 90 112.5 144 180 225 270
Dimensions WxDxH (mm) 815x825x1670 1217x853x1900
UPS weight (kg) 570 600 625 660 715 970 1090 1170
Battery configuration External, 300 to 312 cells, VRLA (other options)
Input
Connection type Hardwired 3w (rectifier), 4w (bypass)
Nominal voltage 400 Vac 3-phase (rectifier) ; 380/400/415 Vac 3-phase with neutral (bypass)
Voltage tolerance -20%, +15% (rectifier); ±10% (bypass)
Frequency and range 50/60 Hz, 45 to 65 Hz
Power factor 0.99
Current distortion (THDi) <3%
Output
Connection type Hardwired 4w
Nominal voltage 380/400/415 Vac 3-phase with neutral
Frequency 50/60 Hz
Voltage regulation Static: ±1% ; Dynamic: IEC/EN 62040-3 Class 1
Power factor Up to 0.9, without power derating
Inverter: 125% for 10 min, 150% for 1 min, 199% for 10 s;
Overload capacity
bypass: 150% continuous, 1000% for 1 cycle
Efficiency (AC/AC)* Up to 98%
Classification by IEC/EN 62040-3 VFI-SS-11
Connectivity and function extensions
Front panel Graphic display, mimic LED panel and keyboard, local EPO
Included: serial RS232 and USB; input terminal block for: remote emergency
power off (REPO), battery circuit breaker aux. cont., external maintenance bypass
circuit breaker aux. cont., diesel mode aux. contact.
Remote communication Optional: SNMP adapter (Ethernet), Web interface (Ethernet), ModBus-TCP/IP
(Ethernet); ModBus-RTU (RS485); ModBus-RTU to PROFIBUS DP adapter;
SPDT contact relay board; remote system monitoring panel;
UPS managing and server shutdown software
Isolation transformer; transformers/autotransformers for voltage adjustment; external maintenance bypass; custom battery
Optional function extensions cabinets; wall-mounted battery fuse switch box; battery thermal probe; parallel kit, top cable entry; load-sync for single UPS
and load-sync box (2 UPS systems); backfeed protection; other options on request
System
Protection degree IP 20 (other options)
Colour RAL 7016 (other options)
Installation layout Wall, back to back and side by side installation allowed
Accessibilty Front and top access, bottom cable entry
*according to IEC/EN 62040-3

Other features
Environmental
Operating temperature range 0°C to +40°C
Storage temperature range -10°C to +70°C
Altitude (AMSL) < 1000 m without power reduction, > 1000 m with reduction of 0.5% per 100 m
Audible noise at 1 m (dBA) < 62
Standards and certifications
Quality assurance, environment,
ISO 9001:2015, ISO 14001:2015, BS OHSAS 18001:2007
health and safety
Safety IEC/EN 62040-1
EMC IEC/EN 62040-2
Environment aspects IEC/EN 62040-4
Test and performance IEC/EN 62040-3
Protection degree IEC 60529
Marking CE

www.borri.it
42 B9600FXS | 400 kVA - 800 kVA

UPS 3-PHASE

B9600FXS
from 400 kVA to 800 kVA

www.borri.it
B9600FXS | 400 kVA - 800 kVA 43

Applications

Medium Network Industrial Medical Building


data centre & Server controls & process equipment automation
automation

Rugged design and Transformer


high reliability based design
Customisable UPS for Reliable design with output
specific process industry Minimum isolation transformer for
applications. maintenance costs DC/AC galvanic protection.
Full front accessibility to
all components and high
material quality extremely
reduce servicing.

Transformer-based UPS designed for safety and emergency systems, process control devices
and machine tooling, critical infrastructures, medical equipment, small and medium data centres
monolithic power protection.

www.borri.it
44 B9600FXS | 400 kVA - 800 kVA

B9600FXS: reliable, high power transformer based power solution.

Features and benefits


Built-in inverter transformer for Dynamic Charging Mode (DCM)
DC/AC galvanic protection of for maximum versatility in long
industrial type loads. autonomy and low charging time
applications.
Full IGBT technology and electronic
PFC, ensuring 0.99 input PF and Smart parallel management in
THDi<3% for maximum upstream load sharing, load synchronization
sources compatibility. of single UPS systems and load
synchronization of two paralleled
Front access to all critical systems for optimum protection.
components for easy maintenance.
Dual DSP plus microcontroller logics
Included backfeed bypass for top performance and reliability.
contactor for complete protection
and operators’ safety without CAN-bus based distributed parallel
additional installation costs. control ensuring high load sharing
accuracy and no single point of
Hot connection/disconnection failure in parallel systems.
of parallel units for easy system
resizing. Comprehensive set of
communication options for total
Accurate battery management remote monitoring of equipment
providing ripple current operation.
minimization charge current/
voltage control as per batteries Fully compliant with all international
manufacturers’ specifications and product standards for maximum
automatic/manual battery test for quality guarantee.
maximum battery expected life
preservation.

Dynamic Charging BYPASS

Mode (DCM)
The battery charging current
MAINS OUTPUT
can be set above the nominal,
up to the DCM limit, in order to
manage high capacity battery
packs. The extra charging power
is fed to the battery, as long as
the load does not requires it. This
is a firmware enabled feature.

Main options
Manual bypass. Battery voltage temperature Parallel redundant up to 6 units for
compensation. system redundancy.
Bypass isolation transformer.
Battery fuse switch wall-mounted Load-sync option.
Transformers/autotransformers for box.
voltage adjustment. Top cable entry.
Associated battery cabinets for long
autonomy times.

www.borri.it
B9600FXS | 400 kVA - 800 kVA 45

B9600FXS technical data


Rating (kVA) 400 500 600 800
Nominal Power (kW) 360 450 540 720
Dimensions WxDxH (mm) 1990x950x1920 2440x950x2020 3640x950x1920
UPS weight (kg) 1955 2482 2535 3600
Battery configuration External, 300 to 312 cells, VRLA (other options)
Input
Connection type Hardwired 3w (rectifier), 4w (bypass)
Nominal voltage 400 Vac 3-phase (rectifier); 380/400/415 Vac 3-phase with neutral (bypass)
Voltage tolerance -20%, +15% (rectifier); ±10% (bypass)
Frequency and range 50/60 Hz, 45 to 65 Hz
Power factor 0.99
Current distortion (THDi) <3%
Output
Connection type Hardwired 4w
Nominal voltage 380/400/415 Vac 3-phase with neutral
Frequency 50/60 Hz
Voltage regulation Static: ±1% ; Dynamic: IEC/EN 62040-3 Class 1
Power factor Up to 0.9, without power derating
Inverter: 125% for 10 min, 150% for 1 min, 199% for 10 s;
Overload capacity
bypass: 150% continuous, 1000% for 1 cycle
Efficiency (AC/AC)* Up to 98%
Classification by IEC/EN 62040-3 VFI-SS-11
Connectivity and function extensions
Front panel Graphic display, mimic LED panel and keyboard, local EPO
Included: serial RS232 and USB; input terminal block for: remote emergency
power off (REPO), battery circuit breaker aux. cont., external maintenance bypass
circuit breaker aux. cont., diesel mode aux. contact.
Remote communication Optional: SNMP adapter (Ethernet), Web interface (Ethernet), ModBus-TCP/IP
(Ethernet); ModBus-RTU (RS485); ModBus-RTU to PROFIBUS DP adapter;
SPDT contact relay board; remote system monitoring panel;
UPS managing and server shutdown software
Isolation transformer; transformers/autotransformers for voltage adjustment;
maintenance bypass switch in extended cabinet or wall-mounted box; custom battery cabinets;
Optional function extensions wall-mounted battery fuse switch box; battery thermal probe; parallel kit; top cable entry;
load-sync for single UPS and load-sync box (2 UPS systems); other options on request
System
Protection degree IP 20 (other options)
Colour RAL 7016 (other options)
Installation layout Wall, back to back and side by side installation allowed
Accessibilty Front and top access, bottom cable entry
*according to IEC/EN 62040-3

Other features
Environmental
Operating temperature range 0°C to +40°C
Storage temperature range -10°C to +70°C
Altitude (AMSL) < 1000 m without power reduction, > 1000 m with reduction of 0.5% per 100 m
Audible noise at 1 m (dBA) < 62
Standards and certifications
Quality assurance, environment,
ISO 9001:2015, ISO 14001:2015, BS OHSAS 18001:2007
health and safety
Safety IEC/EN 62040-1
EMC IEC/EN 62040-2
Environment aspects IEC/EN 62040-4
Test and performance IEC/EN 62040-3
Protection degree IEC 60529
Marking CE

www.borri.it
46 INGENIO MAX XT | 750 kW - 2.1 MW

SCALABLE HI-POWER
3-PHASE UPS

INGENIO
MAX XT
from 750 kW to 2.1 MW

www.borri.it
INGENIO MAX XT | 750 kW - 2.1 MW 47

Applications

Large Industrial
data centre controls & process
automation

High Efficiency Reduced TCO


Online double conversion High power density in a
VFI with the highest efficiency minimum space maximizing
thanks to the patented Scalable Modules the number of racks and
3-Level Green Conversion Scalable modules servers installed in your data
technology. up to a 2.1 MW UPS centres.
to grow with your needs.

Scalable, high efficiency UPS system supplying reliable uninterrupted quality power to all critical
applications. High efficiency operating modes and easy hot maintenance allow for lowest Capex
and Opex. Flexible configuration and positioning make it totally adaptable to
your facility and business.

www.borri.it
48 INGENIO MAX XT | 750 kW - 2.1 MW

Ingenio Max XT: scalable, flexible and efficient solution for both
data centre and critical applications.

Features and benefits


250 kW or 300 kW MPM scalable >96% VFI online efficiency starting Hot maintainable modules (VFI),
power modules rated at 40°C from 40% load for very low TCO reducing mean time to repair and
operating temperature, for lower and meeting local regulations for ensuring no system downtime.
TCO and high flexibility to grow on subsidies (applies in some countries).
demand. Innovative design, resulting
Up to 99% high efficiency mode. in reduced footprint, ease of
Patented 3-Level Green Conversion maintenance and low audible noise
technology for highest efficiency with Scalable up to 2.1 MW unit power, levels.
optimal component count to increase for N+1 and A+B redundant
reliability. configurations. Hot scalability (in VFI mode) option
to increase the availability of your
Selectable hi-efficiency modes of Available in Central or Distributed system.
operation. Static Bypass and Common or
Modular Battery. Flexible and customisable
mechanical features like top or
bottom connections, L- or back
to back configuration ensuring
maximum system design flexibility.

Centralised 10" colour touch screen


display providing all user info and
history information at a glance.

Green Conversion Battery Care


(GCBC) for extended battery service
life.

Lithium Battery compatible.

Main options
Manual Bypass Module. 50 kA and 100 kA Input SC Load-sync option.
withstand.
Hot-Scalable Extension module. Backfeed protection trip coil.
Peak Shaving.
Input Protection (Input and Bypass).

Fully Scalable System


Power expansion or redundancy can be implemented at a later stage by installing additional MPM modules up to 2.1 MW.

+ + +
DAY 1 : 1200 kW DAY 2 : 1500 kW DAY 3 : 1800 kW DAY 4 : 2100 kW

www.borri.it
INGENIO MAX XT | 750 kW - 2.1 MW 49

INGENIO MAX XT technical data


Rating (kVA) 750 900 1000 1200 1250 1500 1800 2100
N Nominal Power (kW) 750 900 1000 1200 1250 1500 1800 2100
N+1 Nominal Power (kW) 500 600 750 900 1000 1200 1500 1800
MPM module size (kW) 250 300 250 300 250 300 300 300
UPS dimensions WxDxH (mm)* 4090x970x2100 4970x970x2100 5370x970x2100 6250x970x2100 7580x1200x2100 8460x1200x2100
UPS weight (kg)* 3150 3300 4000 4250 4900 5200 6400 7300
Battery configuration External 360 to 372 cells, VRLA (other options)
Input
Connection type Hardwired 4w (rectifier), 4w (bypass)
Nominal voltage 400 Vac 3-phase with neutral (rectifier), 380/400/415 Vac 3-phase with neutral (bypass)
Voltage tolerance -20%, +15% (rectifier); ±10% (bypass)
Frequency and range 50/60 Hz, 45 to 65 Hz
Power factor 0.99
Current distortion (THDi) <3%
Output
Connection type Hardwired 4w
Nominal voltage 380/400/415 Vac 3-phase with neutral
Frequency 50/60 Hz
Voltage regulation Static: ±1%; Dynamic: IEC/EN 62040-3 Class 1
Power factor Up to 1, without power derating

Overload capacity** Inverter: 110% for 10 min, 125% for 5 min, 150% for 30 s ; bypass: 125% continuous, 1000% for 1 cycle
Efficiency (AC/AC)*** Up to 99%
Classification by IEC/EN 62040-3 VFI-SS-11
Connectivity and function extensions
Front panel 10” colour touch screen display, 1024x600 pixels
Included: serial RS232 and USB; input terminal block (remote emergency power off, battery circuit breaker aux. cont.,
external maintenance bypass circuit breaker aux. cont., diesel mode aux. cont., external output circuit breaker aux. cont.,
Remote communication remote transfer to bypass mode); SPDT contact relay board; ModBus-RTU (RS485).
Optional: ModBus-TCP/IP (Ethernet); ModBus-RTU to PROFIBUS DP adapter
Optional features Isolation transformer; custom battery cabinets; battery thermal probe; load-sync; other options on request
System
Protection degree IP 20
Colour RAL 9005
Installation layout Wall, back to back and side by side installation allowed
Accessibilty Front and top access, bottom and top cable entry
Scalability Up to 2.1 MW
*dimensions may vary with configuration. Contact our sales team for confirmation **conditions apply ***according to IEC/EN 62040-3

Other features
Environmental
Operating temperature range 0°C to +40°C with no power derating
Storage temperature range -10°C to +70°C
Altitude (AMSL) < 1000 m without power reduction, > 1000 m with reduction of 0.5% per 100 m
Audible noise at 1 m (dBA) 65
Standards and certifications
Quality assurance, environment,
ISO 9001:2015, ISO 14001:2015, BS OHSAS 18001:2007
health and safety
Safety IEC/EN 62040-1
EMC IEC/EN 62040-2
Environment aspects IEC/EN 62040-4
Test and performance IEC/EN 62040-3
Protection degree IEC 60529
Marking CE

www.borri.it
50 UPSAVER 3VO | 670 kW - 2.67 MW

MODULAR HI-POWER
3-PHASE UPS

UPSAVER
3VO
from 670 kW to 2.67 MW

www.borri.it
UPSAVER 3VO | 670 kW - 2.67 MW 51

BENEFITS

Borri 3rd Generation UPSaver 3vo high power modular UPS Highest overall efficiency
delivers unsurpassed performance for large and hyperscale Highest efficiency means cost savings to your data centre.
data centres providing the highest level of availability for this UPSaver provides VFI high efficiency >96% from 30% loads
power range, lowest power consumption and TCO. to reduce costs in actual site conditions thanks to 3-Level
Green Conversion technology, multi-mode high efficiency
With the most compact high efficiency 333 kW modules the operations and our module current parallel technology.
system can be scaled up to a 2.67 MW in a single UPS or
power paralleled up to 21 MW for higher power.
Modular hot swappable
For more info click on the QR or contact our Borri Data Hot swappable and hot serviceable (VFI) power modules
Centre Sales Team. ensuring lowest MTTR for highest overall availability.

Flexible 3D scalability
Flexible mechanical installation and hot power upgrade.

www.borri.it
52 ECS | 10 kVA - 160 kVA

EMERGENCY CENTRAL SYSTEMS


1- and 3-PHASE

ECS
from 10 kVA to 160 kVA

www.borri.it
ECS | 10 kVA - 160 kVA 53

Applications

Emergency Emergency Fire fighting Safety equipment


and safety systems lighting

Compliant with High overload


EN 50171 capacity
Ensuring a setup and High recharge Designed to withstand
maintenance cost reduction current 120% permanent power
and easier periodical checks. overload capability.
Battery charger
providing 80% autonomy
within 12 hours.

Emergency Central Systems designed in compliance to the international EN 50171 standard,


supplying uninterrupted quality power to emergency and safety installations.
Suitable for emergency and safety systems, emergency lighting, fire fighting and
safety equipment.

www.borri.it
54 ECS | 10 kVA - 160 kVA

ECS: designed to guarantee power supply to your safety system in


case of mains supply failure.

Compliance to Features and benefits Main options


EN 50171standard
Green Conversion AO+EO mode kit.
120% permanent power technology, providing
high efficiency and UPS Isolation transformer.
overload capability.
components’ life extension.
Separate rectifier and
Batteries with 10 years life
Compact transformer free bypass input for E8000 ECS
expectancy.
design for small footprint. 3-phase output models.
Battery polarity reversal
Easy access for fast Parallel kit.
protection.
maintenance and low
MTTR. Backfeed protection
Deep discharge protection.
(standard with 10, 15 and
Short circuit protection. Acid proof battery cabinets 20 kVA ratings).
and racks.
Battery charger to provide
80% autonomy within 12
hours.

Battery charger temperature


compensation.

IP20 metal enclosure as per


EN 60598-1.

E8000 ECS 10-20 kVA INGENIO ECS 100-160 kVA

www.borri.it
ECS | 10 kVA - 160 kVA 55

Operating mode

Changeover mode -
Always On (AO)
Loads are normally fed by the bypass
line, during a mains failure the
inverter takes over the load without
interruption.

Mode without interruption -


Always On (AO)
Loads are normally fed by the
inverter output.

Changeover mode with


additional control switching
device for partial switching
of the load - Always On +
Emergency Only (AO+EO)
The “Always on” part of the load
is fed continuously whilst the
“Emergency Only” part is only fed
upon mains failure.

www.borri.it
56 ECS | 10 kVA - 160 kVA

E8031 ECS - E8033 ECS technical data


Rating (kVA) 10 15 20
Nominal Power (kW) 9 13.5 18
Nominal power as per EN 50171 (kW) 7.5 11.3 15
UPS dimensions WxDxH (mm) 450x670x1200
UPS weight (kg) 100 110 110
Battery configuration External, 360 to 372 cells, VRLA (other options)
Input
3/1-phase units: hardwired 4w (rectifier), 2w (bypass)
Connection type 3/3-phase units: hardwired 4w (separate bypass input
available on request)
400 Vac 3-phase with neutral (rectifier)
Nominal voltage 220/230/240 Vac (3/1-phase bypass)
Voltage tolerance -20%, +15% (rectifier); ±10% (bypass)
Frequency and range 50/60 Hz, 45 to 65 Hz
Power factor 0.99
Current distortion (THDi) <4%
Output
3/1-phase units: hardwired 2w
Connection type 3/3-phase units: hardwired 4w
3/1-phase units: 220/230/240 Vac 1-phase
Nominal voltage 3/3-phase units: 380/400/415 Vac 3-phase with neutral
Frequency 50/60 Hz
Voltage regulation Static: ±1% ; Dynamic: IEC/EN 62040-3 Class 1
Power factor Up to 0.9, without power derating
Overload capacity* 120% continuous, 150% for 10 min
Efficiency (AC/AC)** Up to 98%
Classification by IEC/EN 62040-3 VFI-SS-11
Connectivity and function extensions
Front panel Graphic display, mimic LED panel and keyboard, local EPO
Included: serial RS232 and USB; terminal block for battery breaker auxiliary contact.
Optional: input terminal block (remote emergency power off,
Remote communication external maintenance bypass circuit breaker aux. cont., diesel mode aux. cont.); SNMP adapter (Ethernet),
Web interface (Ethernet), ModBus-TCP/IP (Ethernet), ModBus-RTU (RS485), from ModBus-RTU to PROFIBUS DP adapter;
SPDT contact relay board; remote system monitoring panel; UPS managing and server shutdown software
Isolation transformer; transformers/autotransformers for voltage adjustment;
external maintenance bypass; custom battery cabinets; wall-mounted battery fuse switch box; battery thermal probe;
Optional features load-sync for single UPS; AO+EO mode kit; separate input for rectifier and bypass line (for 3-phase output models);
parallel kit; other options on reques
System
Protection degree IP 20
Colour RAL 7016
Installation layout 10 cm wall-gap, side by side installation allowed
Accessibilty Front and top access, bottom cable entry
*as per EN 50171 **as per IEC/EN 62040-3
Other features
Environmental
Operating temperature range 0°C to +40°C
Storage temperature range -10°C to +70°C
Altitude (AMSL) < 1000 m without power reduction, > 1000 m with reduction of 0.5% per 100 m
Audible noise at 1 m (dBA) < 52
Standards and certifications
CPSS EN 50171
Quality assurance, environment,
ISO 9001:2015, ISO 14001:2015, BS OHSAS 18001:2007
health and safety
Safety IEC/EN 62040-1
EMC IEC/EN 62040-2
Environment aspects IEC/EN 62040-4
Test and performance IEC/EN 62040-3
Protection degree IEC 60529
Marking CE

www.borri.it
ECS | 10 kVA - 160 kVA 57

INGENIO ECS technical data


Rating (kVA) 30 40 60 80 100 125 160
Nominal Power (kW) 30 40 60 80 100 125 160
Nominal power as per EN 50171 (kW) 25 33.3 50 67 83 104 133
UPS dimensions WxDxH (mm) 465x650x1230 560x940x1500 560x940x1800
UPS weight (kg) 120 140 190 215 320 360 380
Battery configuration External, 360 to 372 cells, VRLA (other options)
Input
Connection type Hardwired 4w Hardwired 4w (rectifier), 4w (bypass)
400 Vac 3-phase with neutral (rectifier)
Nominal voltage 380/400/415 Vac 3-phase with neutral (bypass)
Voltage tolerance -20%, +15% (rectifier); ±10% (bypass)
Frequency and range 50/60 Hz, 45 to 65 Hz
Power factor >0.99
Current distortion (THDi) <3%
Output
Connection type Hardwired 4w
Nominal voltage 380/400/415 Vac 3-phase with neutral
Frequency 50/60 Hz
Voltage regulation Static: ±1% ; Dynamic: IEC/EN 62040-3 Class 1
Power factor Up to 1, without power derating
Overload capacity* 120% continuous, 150% for 10 min
Efficiency (AC/AC)** Up to 99%
Classification by IEC/EN 62040-3 VFI-SS-11
Connectivity and function extensions
Front panel Graphic display, mimic LED panel and keyboard, local EPO
Included: serial RS232 and USB; backfeed protection monitoring contact,
input terminal block (remote emergency power off, battery circuit breaker aux. cont.,
external maintenance bypass circuit breaker aux. cont., diesel mode aux. cont.).
Remote communication Optional: SNMP adapter (Ethernet), Web interface (Ethernet), ModBus-TCP/IP (Ethernet), ModBus-RTU (RS485),
from ModBus-RTU to PROFIBUS DP adapter; SPDT contact relay board;
remote system monitoring panel; UPS managing and server shutdown software
Isolation transformer; transformers/autotransformers for voltage adjustment;
external maintenance bypass; custom battery cabinets; wall-mounted battery fuse switch box;
Optional features battery thermal probe; parallel kit, load-sync for single UPS;
AO+EO mode kit; backfeed protection; other options on request
System
Protection degree IP 20
Colour RAL 9005
10 cm wall-gap, side by side
Installation layout Wall and side by side installation allowed
installation allowed
Accessibilty Front and top access,bottom cable entry Front access, bottom cable entry
*as per EN 50171 **as per IEC/EN 62040-3

Other features
Environmental
Operating temperature range 0°C to +40°C
Storage temperature range -10°C to +70°C
Altitude (AMSL) < 1000 m without power reduction, > 1000 m with reduction of 0.5% per 100 m
Audible noise at 1 m (dBA) < 60
Standards and certifications
CPSS EN 50171
Quality assurance, environment,
ISO 9001:2015, ISO 14001:2015, BS OHSAS 18001:2007
health and safety
Safety IEC/EN 62040-1
EMC IEC/EN 62040-2
Environment aspects IEC/EN 62040-4
Test and performance IEC/EN 62040-3
Protection degree IEC 60529
Marking CE

www.borri.it
58 STS | 16 A - 3000 A

STATIC TRANSFER SWITCHES


1- and 3-PHASE

STS
from 16 A to 3000 A

www.borri.it
STS | 16 A - 3000 A 59

Applications

Network Data centre Industrial


& Server controls & process
automation

Short circuit High availability


protection Thanks to source separation,
Ensuring maximum source No break dual maintenance bypass
protection in dual feed seamless transfers and redundant crititical
applications. paths.
Automatically transferring loads
to alternative power sources
when the primary power
source fails or is not available.

1-Phase and 3-Phase static transfer switches for seamless load transfer in dual path power
systems. The STS rugged design and high reliability provides supply redundancy and
prevents fault propagation.

www.borri.it
60 STS 16-32 | 16 A - 32 A

1-PHASE STATIC TRANSFER SWITCHES

STS 16-32 1-phase static transfer switch series


designed to offer solutions for
from 16 A to 32 A the protection of single-phase loads.

Features and benefits


Dual redundant power ITS maintenance
supplies to control switch, for hot swap
boards, for increased maintainability.
availability.
Compact 19” rack
STS 16-32 front view
Redundant cooling and system design, for easy
fan failure monitoring, for integration.
reliable operation.
LCD/LED display,
Real-time SCR fault providing user friendly
sensing, preventing fault interface.
propagation.
Comprehensive set
High overload of communication
capability, for robust options for total remote
electrical design. monitoring of equipment
STS 16 rear view
operation.

Main options
ITS maintenance switch. SNMP interface.

RS485 ModBus
interface.
STS 32 rear view

ITS maintenance switch STS block diagram


main features

16 A and 32 A version. BYPASS 1

6 x 40 A input terminal board.


SOURCE 1 INPUT 1
Zero switching time.
OUTPUT LOADS

SOURCE 1 INPUT 2

BYPASS 2

optional ITS

www.borri.it
STS 16-32 | 16 A - 32 A 61

STS 16 - STS 32 technical data


Model STS 16 STS 32
Rating (A) 16 32
Dimensions WxDxH (mm) 440x275x88
Weight (kg) 8 9
Input
Connection type Hardwired 5w
Nominal voltage 200/208/220/230/240 Vac 1-phase
Voltage tolerance ± 5% (up to ±20%)
Absolute maximum voltage range 150 Vac to 300 Vac
Frequency and range 50/60 Hz, ± 5% (up to ±20%)
Source harmonic voltage content Unlimited
Transfer phase angle 5° to 20°
Output
Connection type 8 IEC-C 13, hardwired 3w Hardwired 3w
Nominal voltage 200/208/220/230/240 Vac 1-phase
Frequency 50/60 Hz
Transfer time 2 to 6 ms
Transfer mode Break before make, transfer inhibit on fault
Load power factor 1 to 0.3
Maximum crest factor 3:1
THD current feedback from load Unlimited
Overload capacity 125% for 1 min, 150% for 30 s, 200% for 5 s
Efficiency (AC/AC) 99%
Connectivity and function extensions
Front panel Graphical LCD display
Included: RS-232 ModBus, USB, voltage free relay contacts;
Remote communication
Optional: one slot for SNMP adapter or RS-485 ModBus adapter
System
Protection degree IP 20
Colour RAL 9005
Installation layout Rack mounted
Accessibilty Front and rear

Other features
Environmental
Operating temperature range -5°C to +40°C
Storage temperature range -10°C to +70°C
Altitude (AMSL) < 1000 m without power reduction, > 1000 m with reduction of 0.5% per 100 m
Audible noise at 1 m (dBA) < 60
Standards and certifications
Quality assurance, environment,
ISO 9001:2015, ISO 14001:2015, BS OHSAS 18001:2007
health and safety
Safety IEC 60950-1
EMC EN 55022, EN 55024
Transfer voltage limit IEEE Standard 446
Protection degree IEC 60529
Performance IEC/EN 62310-3
Marking CE

www.borri.it
62 STS 300 | 100 A - 3000 A

3-PHASE STATIC TRANSFER SWITCHES

STS 300
3-phase centralised static transfer
switch series designed to offer solutions
from 100 A to 3000 A for the protection of loads even in harsh
environment.
Features and benefits
Continuous monitoring of all system control boards
voltage and frequency for top product reliability
and automatic instant in high availability
(<4 ms) transfers for applications.
secure power switching
without cross connection Full front access for easy
between sources. maintenance.

Short circuit transfer Bottom and top cable


inhibit for robust load entry for maximum
protection. installation versatility.

SCR fault detection and Comprehensive set


backfeed protection of communication
for maximum upstream options for total remote
safety. monitoring of equipment
operation.
Dual manual bypass
for complete source Fully compliance with
independence during all international product
maintenance. standards for maximum
quality guarantee.
True oversized neutral
(2x In), redundant Circuit breakers for
STS block diagram cooling with monitored reliable and safe
fans and redundant (3x3) tripping on all operating
internal power supply in conditions.
BYPASS 1

SOURCE 1 INPUT 1
Main options
OUTPUT LOADS
Isolation transformer. Additional SPDT contact
relay board.
Plug-in breakers.
SOURCE 1 INPUT 2 4-pole configuration.
Output distribution panels.
Operation without neutral.
Panel builder version.
BYPASS 2

Dry contact relay card RS485 ModBus-RTU port


(Included) (Included)
To send UPS status to PLC’s, To send UPS status to BMS’s
SCADA’s or AS400’s by voltage by RS485 connection and
free SPDT contacts ModBus-RTU protocol. For remote
monitoring and remote service

www.borri.it
STS 300 | 100 A - 3000 A 63

STS 300 technical data


Rating (A)* 100 250 400 630 800 1000 1250
Dimensions WxDxH (mm)** 820x835x1475 1220x860x1900 2000x1000x2100
Weight (kg)** 265 290 305 615 660 1000 1450
Input
Connection type Hardwired 4w
Nominal voltage 208/380/400/415/440/480 Vac 3-phase with neutral
Voltage tolerance ±10% (up to ±20% on request)
Frequency and range 50/60 Hz, ±2 Hz (up to ±4 Hz on request)
Source harmonic voltage content Unlimited (if THD>20% transfer time ≤10ms)
Transfer phase angle 5° to 30°
Output
Connection type Hardwired 4w
Nominal voltage 208/380/400/415/440/480 Vac 3-phase with neutral
Frequency 50/60 Hz
Transfer time ≤4 ms
Transfer mode Break before make, transfer inhibit on fault
Load power factor 1 to 0.3
Maximum crest factor 3:1
THD current feedback from load Unlimited
Overload capacity*** 125% for 30 min, 150% for 10 min, 200% for 30 s, 2000% for 1 cycle, 4000% for ½ cycle
Efficiency (AC/AC) >99%
Connectivity and function extensions
Front panel Graphical LCD display, mimic LED panel and keyboard
Included: dry contact relay card, RS232 and RS485 serial ports,
Remote communication ModBus-RTU protocol.
Optional: additional dry contact relay card
4-pole configuration; plug-in circuit breakers;
operation without neutral;
Optional function extensions panel builder execution;
output distribution panels; isolation transformer
System
Protection degree IP 20 (other options)
Colour RAL 9005 (other options)
Installation layout Wall, back to back and side by side installation allowed
Accessibilty Front access, bottom and top cable entry
*rating up to 3000 A on request **3-pole version *** conditions apply

Other features
Environmental
Operating temperature range 0°C to +40°C
Storage temperature range -10°C to +70°C
Altitude (AMSL) < 1000 m without power reduction, > 1000 m with reduction of 0.5% per 100 m
Audible noise at 1 m (dBA) <62
Standards and certifications
Quality assurance, environment,
ISO 9001:2015, ISO 14001:2015, BS OHSAS 18001:2007
health and safety
Safety IEC/EN 62310-1
EMC IEC/EN 62310-2
Breakers IEC/EN60947-3
Transfer voltage limits IEEE Standard 446
Protection degree IEC 60529
Performance IEC/EN 62310-3
Marking CE

www.borri.it
64 3-PHASE UPS ’S | OPTIONS

3-PHASE UPS’S OPTIONS


Description When do I use it

PARALLEL KIT When the unit is to be paralleled for load sharing


Load

LOAD SYNC To synchronize single units’ output for no-break load transfers by
FOR SINGLE UNITS downstream static transfer switches
Load A Load B

LOAD
SYNC
To synchronize the output of two paralleled UPS systems for no-break
BOX
LOAD SYNC BOX load transfers by downstream static transfer switches
Load A Load B

Bypass
BACKFEED INTERNAL To be fully protected against backfeed energy upon static bypass
Mains Output TRIPPING DEVICE failure

TOP CABLE ENTRY To allow input and output cable entry from the top of the unit

Transformer ISOLATION To galvanically isolate UPS from load or to change system’s earth
Input QRA
TRANSFORMER arrangement
Transformer Cabinet

BATTERY FUSED To disconnect and protect an external battery pack


Fused Switch SWITCH BOX

BATTERY TEMPERATURE PROBE For charging voltage compensation against temperature

Input terminal block When the Emergency Power Off (EPO) has to be commanded by a
FOR REMOTE EPO remote control button

Input terminal block FOR EXTERNAL When there is an external maintenance bypass switch, for state
MANUAL BYPASS monitoring
SWITCH AUXILIARY CONTACT

Input terminal block


FOR EXTERNAL BATTERY SWITCH When there is an external battery switch, for state monitoring
AUXILIARY CONTACT
i Input terminal block
FOR EXTERNAL OUTPUT CIRCUIT When there is an external output breaker, for status monitoring
BREAKER

Input terminal block When the transfer to bypass mode can be commanded by an
FOR REMOTE BYPASS TRANSFER external contact

Input terminal block When battery recharge has to be inhibited over genset operation
FOR DIESEL MODE CONTACT

VOLT FREE To send UPS status to PLC’s, SCADA’s or AS400’s by voltage free
CONTACT CARD SPDT contacts

To monitor UPS status by a LED panel from a remote control room


REMOTE MONITORING PANEL (relay card required)

To send UPS status to BMS’s by RS485 connection and ModBus-RTU


RS485 MODBUS-RTU PORT protocol.For remote monitoring and remote service

To send UPS status to BMS’s by Ethernet connection and SNMP


or ModBus over IP protocol. To monitor UPS status by any internet
WEB/SNMP ADAPTER browser from workstations. To receive SMS or e-mail alerts from the
UPS on any portable device

www.borri.it
3-PHASE UPS ’S | OPTIONS 65

Included Optional

B8031FXS Ingenio Ingenio Plus Ingenio Max B9000FXS B9600FXS Ingenio Max XT
B8033FXS Compact

Contactor Tripping coil Tripping coil Tripping coil


Included (Included output (Included output (Included output Included (Included output
contactor Contactor
contact for external contact for external contact for external contactor contact for external
tripping device) tripping device) tripping device) tripping device)

Custom Custom Custom Included


version only version only version only on demand

Input Input transformer,


transformer, internal Input transformer, internal up to Input transformer, Bypass transformer, Bypass transformer, Input transformer,
or extended cabinet. extended cabinet 80 kVA or extended cabinet extended cabinet extended cabinet extended cabinet
Output transformer extended cabinet
for B8031FXS

For internal
For internal or exter- For internal or exter- up to 80 kVA or For external battery For external battery For external battery For external battery
nal battery nal battery external battery

Included in
60-160 kVA

Included in
60-160 kVA

Included in
60-160 kVA

Included in
60-160 kVA

Included in
60-160 kVA

www.borri.it
66 GUARDIAN NET

GUARDIAN NET
REMOTE DIAGNOSTICS
AND PREVENTIVE
MONITORING
Guardian Net improves Business Continuity
by remote diagnostics and preventive
monitoring of your UPS system and
peripherals by preventing unpredictable
anomalies to become failures.

Early detection of any deviations of critical


parameter and prompt reaction in case
of alarms result in extended uptime and
enhanced operational efficiency. Real time
monitoring and periodic reports on the
health of equipment provide complete peace
of mind, delivering unparalleled support
experience.

www.borri.it
GUARDIAN NET 67

BENEFITS FEATURES

Extending Uptime Web Proactive Maintenance


Together with a Borri Maintenance Contract, Guardian Net Our Service specialists monitor your equipment from the Borri
allows our Service specialists to take care of your system by Service Centre, analysing data and trends, to proactively
monitoring its parameters and quickly reacting to anomalies. recommend actions for ensuring equipment always performs
at its best.
Increasing Business Continuity Warning and alarm notification
Guardian Net provides you with continuous monitoring
Guardian Net continuously monitors the system and should
of your system, giving you comprehensive operational
any critical parameters exceed the preset tolerance, it
awareness and providing technical recommendations and
generates a warning or alarm notification to you and the
reports by Borri Service Centre for improving the quality and
Borri Service Centre. Our Service specialists will investigate
reliability of your system.
the data, find the cause and take actions based on the
customer’s maintenance contract. This ensures that in case
Reducing Total Cost of Ownership Service engineers are dispatched on-site, they arrive
Guardian Net is an on-site virtual Service specialist 24/7, prepared for first time resolution, reducing downtime and
monitoring all relevant parameters, maximizing system increasing system availability.
performance, reducing on-site maintenance and minimizing
your total cost of ownership by extending the life of your Status Reports
critical equipment. The unit parameters are collected by our Service Centre
and presented in periodic status reports. You will receive
a comprehensive analysis of your equipment and its
operational performance, as well as demonstration that it is
under continuous remote monitoring.

Total Service Support


Borri supports critical infrastructures with a comprehensive
offering of their Service specialists, enhancing system
availability and ensuring total peace of mind 24/7.

Data Manager Unit (DMU) technical data


To monitored device
Communication port RS485 ModBus
Protocol ModBus-RTU/ASCII slave
Max no. of connected devices* 16
To Service Centre
Communication port RJ45 Ethernet
Protocol Open VPN (based on Open SSL), http, SMTP, ModBus-TCP/IP
Services Web Server, NTP time stamping
Notification Included: email - Optional: text message via https or via RS232 modem
Options
30 h backup battery, system integrator version (no box), GSM/GPRS modem (SIM card not included)
System
Power supply 100 to 240 Vac
Installation Wall-mounted box
Dimensions WxDxH (mm) 400x200x400
Weight 15 kg (w/ backup battery), 12 kg (w/o backup battery)
Protection degree IP 20 (IP 65 on request)
Colour RAL 7035
Environmental
Operating temperature range 0°C to 40°C
Storage temperature range -10°C to 70°C
*conditions apply

www.borri.it
68 UPS | INDUSTRIAL POWER SOLUTION

POWER
PROTECTION
SOLUTIONS FOR
HARSH INDUSTRIAL
APPLICATIONS
from 5 kVA to 2000 kVA

AC UPS

E2001 UMB AC
Industrial 1-Phase UPS Industrial Modular UPS
from 5 to 200 kVA from 10 to 320 kW

E3001
Industrial 3-Phase UPS
from 5 to 600 kVA

www.borri.it
UPS | INDUSTRIAL POWER SOLUTION 69

OIL & GAS POWER GENERATION


AND WATER TREATMENT

POWER TRANSMISSION TRANSPORTATION


& DISTRIBUTION

CHEMICAL, MINING AND METALLURGY PROCESS INDUSTRY

DC UPS

IMB Ingenio SFC RTB GMC.igbt


Industrial 1-Phase Inverter Static Frequency Converter Industrial 3-Phase Rectifier Green Mobility
from 5 to 200 kVA from 100 to 2000 kVA 24 V - 220 Vdc Charger for E-Bus
from 50 to 2000 A 300-600-1000 A
ITB UMB DC
Industrial 3-Phase Inverter Industrial Modular Rectifier
from 5 to 600 kVA from 24 V to 220 Vdc

www.borri.it
70 SERVICE

SERVICE

Customer’s expectation defines Borri’s priority from the early analysis of the project requirements to a worldwide commissioning and
service. Many thousands of systems have been successfully installed and maintained globally, with continuous support from a highly
trained team of expert, certified technicians and engineers. From the professional set-up of Borri’s training centre or on site, the training
and service team stand ready to provide support and contribute to tailored training at Borri or on site.You can be assured of Borri
support to the highest standards no matter where in the world you are.

Planning, installation, Maintenance


commissioning Preventive maintenance guarantees
Borri assist you in every single step of your uninterrupted operations and optimised
project. Our R&D team can analyse and system efficiency.
develop solutions to a wide range of edge
system requirements.

Battery tests
Batteries have a limited time life and their
Analytical tests proper maintenance is of high importance to
Borri undertakes a series of analytical tests guarantee efficiency to the UPS and avoid
in order to guarantee higher efficiency and potential failures. Borri delivers high quality
continuity to your system operation. and performing batteries to assure smooth
operations.

Repair & spare parts


Training
All spare parts supplied by Borri are original,
tested and guaranteed to be fully compliant Borri offers distributors and customers a
with Borri solutions. service training structured in 3 levels. Courses
can be held in Borri training centres or on-
site.

Remote monitoring
Guardian Net remote monitoring system
allows you to detect any deviation from
optimum operation and trigger proper and
immediate response, so that anomalies don’t
evolve into issues.

www.borri.it
Since 1932,
securing your
power with passion
and commitment.

OMG60326revC | 07-2022
Due to our policy of continuous
development, data in this document
is subject to change without notice
and becomes contractual only after
written confirmation
www.borri.it

BORRI HEADQUARTERS BORRI SUBSIDIARIES


AND FACTORY AND SERVICE CENTRES

Borri S.p.A
Americas India
Via 8 Marzo, 2
Borri Power (US) Inc. Borri Power India Pvt. Ltd.
52011 Bibbiena (AR)
Italy 9000 Clay Road, Suit 104 Plot No. 69, Ground Floor
Tel. +39 0575 5351 Houston, Texas, 77080 Nagarjuna Hills, Panjagutta
Fax +39 0575 561811 USA Hyderabad, 500 082
[email protected] Tel. +1 346 212 2686 India
Fax +1 346 980 8875 Tel. +91 40 2335 4095
[email protected] [email protected]

Asia Pacific Middle East and Africa


Borri Asia Pacific Borri Power
Engineering Sdn. Bhd. Middle East FZCO
No.13, Jalan Serendah 26/41, 1-151, Techno Hub
Sekitar 26, Seksyen 26, PO Box: 342036
40400 Shah Alam, Selangor Dubai Silicon Oasis, Dubai UAE
Malaysia Tel. +971 4 3200528
Tel. +60 3 5191 9098 Fax +971 4 3200529
Fax +60 3 5103 8728 [email protected]
[email protected]

You might also like