Smart Trip Unit
Smart Trip Unit
alarms.
NFC and Bluetooth built-in and Smart add-on modules can be configured. Monitoring and monitoring is possible
through service access anytime, anywhere by securing a Smart LV solution through ICT convergence technology.
Exterior
Relay fine
• L, S, I Pickup current
adjustment
P type ERMS
• Control by DI and • Control by DI and • Control by DI and
communication communication communication
• Device operation through self-power
• Device operation via AC or DC • Supports L relay element • Supports L relay element • Supports L relay element • Supports L relay element
IDMTL support Thermal and DT, SIT, VIT, Thermal and DT, SIT, VIT, Thermal and DT, SIT, VIT, Thermal and DT, SIT, VIT,
• Current/voltage/frequency/power
EIT, EIT50 EIT, EIT50 EIT, EIT50 EIT, EIT50
relay function
• 3.5” Graphic Display
Trip information
• DO output maintenance LED
• L, S, I, G/PTA, SP • L, S, I, G/Gext/PTA, SP • L, S, I, G/Gext/PTA, SP • L, S, I, G/Gext/PTA, SP
• Supports USB communication
• Supports RS485 communication • 32 accident events • 127 accident events • 127 accident events
Screen indicated [Accident phase/ indicated [Accident phase/ indicated [Accident
current/time] current/time] phase/current/time]
32 33
Smart LV Solution
Smart Trip Unit Smart ACB
STU types and Type N Type A Type P Type S Type N Type A Type P Type S
main functions • Current [R/S/T/N] • Current [R/S/T/N] • 3-phase phase voltage, • 3-phase phase voltage, • USB [for on-site operator] • USB [for on-site operator] • USB [for on-site operator] • USB [for on-site operator]
• Current phase (A phase • External CT current line voltage line voltage (Communication type • RS485 / Modbus • RS485 / Modbus • RS485 / Modbus
Communication
current standard) • Current phase (Based • Current [R/S/T/N] • Current [R/S/T/N] only) (Communication type • BLE
• Vector sum image on phase A current) • Frequency • Frequency only) • NFC
current • Vector sum image • External CT current • External CT current
• [Operation when 30% • [Operation when 30% • [Operation when 30% • [Operation when 30%
• Normal and reverse current • Voltage/current phase • Voltage/current phase
or more of rated current, or more of rated current, or more of rated current, or more of rated current,
phase current • Normal and reverse (Based on phase A voltage) (Based on phase A voltage)
based on single-phase based on single-phase based on single-phase based on single-phase
• Current imbalance rate phase current • Total/each phase power [P, Q, S] • Total/each phase power [P, Q, S]
Power load standard] load standard] load standard] load standard]
• Current demand before • Current imbalance rate • Total/each power factor • Total/each power factor
• AC/DC 88 ~ 264V • AC/DC 88 ~ 264V • AC/DC 88 ~ 264V
each phase • Current demand before • Positive/reverse, effective/ • Positive/reverse, effective/
• DC 24 ~ 48V(Future • DC 24 ~ 48V(Future • DC 2 4~ 48V(Future
each phase invalid/apparent energy invalid/apparent energy
development) development) development)
Measurement • Vector Sum image voltage • Vector Sum image voltage
function • Vector sum image current • Vector sum image current • 255 device status changes • 255 device status changes • 255 device status changes • 255 device status changes
Event record
• Normal and reverse phase • Normal and reverse phase [Details, status, date] [Details, status, date] [Details, status, date] [Details, status, date]
voltage voltage
• Normal and reverse phase • Normal and reverse phase • RTC built-in • RTC built-in • RTC built-in • RTC built-in
Clock
current current (Back up with battery) (Back up with battery) (Back up with battery) (Back up with battery)
• Voltage unbalance rate • Voltage unbalance rate
• Run, alarm, • Run, alarm, • Run, alarm, • Run, alarm,
• Current imbalance rate • Current imbalance rate Other LED
Self-diagnosis, comm. Self-diagnosis, comm. Self-diagnosis, comm. Self-diagnosis, comm.
• Current demand before • Current demand before
each phase each phase
• Reset button • Reset/menu/tap/up/ • Reset button • Reset button
• Demand on the last • Demand on the last Operation button
down/enter • LCD Touch • LCD Touch
apparent, reactive, apparent, reactive,
or active power or active power • RUN/AL LED flashing • RUN/AL LED flashing • RUN/AL LED flashing • RUN/AL LED flashing
LED
(Red ↔ Blue flashing) (Red ↔ Blue flashing) (Red ↔ Blue flashing) (Red ↔ Blue flashing)
Current 0.5% 0.5% 0.5% 0.5%
Displays the corresponding Can be checked on the Can be checked on the
Voltage 0.5% 0.5%
LCD segment or error number on LCD self-diagnosis screen LCD self-diagnosis screen
Measurement
class 1.0 class 1.0 the LCD
accuracy
Power
(IEC 62053 - 21, 22) (IEC 62053 - 21, 22)
• Battery Low Alarm : Occurs when the internal battery is not inserted or when the battery voltage is low
• Rating Plug Unattached or Error : Occurs when rating plug is not assembled or when there is rating plug error
Frequency 50, 60 Hz device classification 50, 60 Hz device classification 0.1% (10 ~ 200Hz) 0.1% (10 ~ 200Hz)
• Ampere Frame Error : Occurs when the value of rating plug is not within 45%~100% of AF
• 63rd harmonic current • 63rd harmonic current • 63rd harmonic current • 63rd harmonic current • MTD Fail : Occurs when STU is not assembled with MTD or trip coil disconnection occurs
• Current THD, TDD, K - • Current THD, TDD, K - • Voltage THD • Voltage THD • Factory Cfg Error : Occurs when the factory mode setting is entered incorrectly
PQ function Self-
Factor Factor • Current THD, TDD, K - • Current THD, TDD, K - • Device Type Erro r: Occurs when the rating plug information and CT information are different
diagnosis • Over Heat Error : Occurs when CPU internal temperature N/A type exceeds 100 degrees and P/S type exceeds
Factor Factor
115 degrees
• Max Current demand • Max Current demand • Max Current demand • Max Current demand
• Contact Wear Alarm : Occurs when CPU internal temperature N/A type exceeds 100 degrees and P/S type
• Max Io • Max Io • Max active/reactive/apparent • Max active/reactive/apparent List
exceeds 115 degrees
• Max In • Max Ext Io power power
• Electrical Open Count Over Alarm : Occurs when the electrical open count exceeds 80% of the allowable
• Max internal temperature • Max In • Demand • Demand
electrical open count
Measurement • Max internal temperature • Max active power • Max active power
• Mechanical Open Count Over Alarm : Occurs when the mechanical open count exceeds 80% of the allowable
record • Max Vo • Max Vo
mechanical open count
• Max Io • Max Io
• RTC Erro r: Occurs when an error occurs in the internal RTC information
• Max Ext Io • Max Ext Io
• Memory Error : Occurs when corruption occurs in the redundant internal settings stored in the internal non-
• Max In • Max In
volatile memory
• Max internal temperature • Max internal temperature
• CT disconnection error : Occurs when CT disconnection occurs (monitoring by each phase)
• Can be checked by • Can be checked by • Can be checked by
Real - time communication communication communication
waveform • Can be checked on the LCD • Can be checked on the LCD
screen screen
34 35
Smart LV Solution
Smart Trip Unit Smart ACB
Common
ZSI Output
Temperature
ZSI Input
Power supply
Module
Reset
OFF
OFF
ZCT
ON
CG FG E1 Z3 Z1 485+ R11 R22 513 R2 R1 251 83 D1 C11 C1 A1 U1 413 423 61 51 41 31 21 21 53 43 33 23 13 T1 TC1 T2 TC2 341 331 321 311 381 371 361 351
GD 183
/EM(+) /RES(+)
CL2 (CONNECTED)
CL1 (CONNECTED)
CL6 (CONNECTED)
CL5 (CONNECTED)
CL4 (DISCON) or
CL8 (DISCON)
CL4 (TEST)
CL3 (TEST)
CL7 (TEST)
Temperature Temperature
Sensor-1 Sensor-2
Axa
Axb
Axb
ACB
Axb
Axb
Axb
Axb
Axb
Axa
Axa
Axa
Axa
Axa
Trip relay UVT SHT2 SHT1 CC
or
N
C
B
Voltage M
A Module
GD
/EM(-) E2 Z4 Z2 485- 544 534 524 252 84 184
/RES(-) D2 C12 C2 A2 U2 414 424 52 42 32 22 12 54 44 34 24 14 342 344 332 334 322 324 312 314 382 384 372 374 362 364 352 354
OFF
ON
Charged
Charged
STD/Inst
LTD
GTD
Secondary SBC
Ready to close (Shorting b-contact)
trip coil Cell switch 8C
13 14 ~ 63 64 Auxiliary switch "NO" D1 D2 Voltage input terminal of UVT Z1 Z2 ZSI input Axa , Axb Auxiliary switch
Internal / External wiring (by customer)
11 12 ~ 61 62 Auxiliary switch "NC" 83 84 Alarm1 "NO" Z3 Z4 ZSI output LTD Long time delay trip indicator
413 414 Charged signal 183 184 Alarm2 "NO" E1 E2 ZCT STD/Inst Short time delay/instantaneous
Connector of the control circuit terminal of drawout type
423 424 Charged signal communication 251 252 Ready to close switch GD
/EM(+)
GD
/EM(-)
Group DI or ERMS DI GTD Ground fault trip indicator
Note) 1. The diagram is shown with circuit de-energized, all devices open, connected and charged and
relays in normal position
2. Relay is normal condition and charging type is "OFF-Charging"
3. The standard of auxiliary contact is 3a3b. The auxiliary switch in above diagram is composed of 5a5b.
See 48 page for more detail on auxiliary switches.
4. Option
- Ready to close contact, Trip alarm contact, UVT coil, Fully charged contact, secondary trip coil
- Cell switch, Temperature module, Voltage module, Remote close-open module, ZCT, ZSI
5. Please consult us for the use of ZSI (Zone selective Interlocking).
6. Refer to the page 33 for the connection of Trip relay and the page 43 for UVT.
7. For connecting RS-485 verify if the polarity is correct
8. Contact configuration for Cell Switch can be changeable if necessary
36 37
Smart LV Solution
Smart Trip Unit Smart ACB
System diagram
BLOCK DIAGRAM OF TRIP RELAY BLOCK DIAGRAM OF TRIP RELAY BLOCK DIAGRAM OF TRIP RELAY BLOCK DIAGRAM OF TRIP RELAY
(ACB 4P) (ACB 4P) (ACB 3P) (ACB 3P)
A B C N A B C N A B C A B C
ACB ACB ACB TRIP ACB TRIP ACB ACB ACB TRIP ACB TRIP
(4P) (4P) (3P) (3P)
Vcc/+5V Vcc +5V +24VVcc/+5V Vcc +5V +24V
CN2-1
CPU Display CN2-1 CPU Display CN2-1 CN2-1
Filter Filter
LED LCD LED LCD
Amplifier Amplifier
CN2-10 CN2-10
CN2-3 CN2-3 CN2-3 CN2-3
CT CT Main PCB
Ass'y
Main PCB
Ass'y CT CT
CN2-7 CN2-7 CN2-7 CN2-7
Setting Setting
CN2-14 Part CN2-14 Part CN2-14 CN2-14
38 39
Smart LV Solution
2. Features
• Susol MCCB features ............................................................ 44
Super performance
The third breaking performance guarantees
the original performance.
TS1600
TS800 Rated current : 1000, 1250, 1600A
Icu : 50kA (N), 70kA (H), 150kA (L)
Ics = Icu
TS400/630 Rated current : 700, 800A
210 (W) × 327 (H) × 152.5mm (D)
Icu : 65kA (N/Ni), 100kA (H/Hi), 150kA (L/Li)
Rated current : 300~630A Ics = Icu
TS100/160/250 Icu : 65kA (N/Ni), 85kA (H/Hi), 150kA (L/Li) 210 (W) × 320 (H) × 135mm (D)
Ics = Icu
Rated current : 40~250A 140 (W) × 260 (H) × 110mm (D)
150kA TS1600L TS1600H TS1600N
(AF)
TD100/160 Icu : 50kA (N/Ni), 85kA (H/Hi),
150kA (L/Li)
100kA TS1250H TS1250N
42 43
Smart LV Solution
Susol MCCB features Susol Smart MCCB
FMU
Thermal electronic FMU
FTU - DSU
type FTU
ATU
Trip ETSi
ETS ETMi
unit Electronic
- ETM Note 2) -
release ETHi
ETLi
N type A type
OCR - - -
P type S type
100~800AF
For line and device protection
1. Thermal magnetic trip units 2. Electronic trip units
- FTU : Fixed thermal, fixed magnetic trip unit - ETS/ ETSi : Standard
- FMU : Adjustable thermal, fixed magnetic trip unit - ETM/ ETMi : Multi-Function
- ATU : Adjustable thermal, adjustable magnetic trip unit - ETHi : High-Performance
- ETLi : Limited-Performance
Susol circuit breaker's Brain-Trip unit
The trip unit has the core function of monitoring the system and sending an interruption (trip) signal when an error
occurs. The Susol circuit breaker have optional adjustable devices for each item as well as simple fixed trip devices. For motor protection For switch disconnector
It provides the optimal solution for selection according to the type of load and operation coordination between upper
MTU : Magnetic only trip unit DSU : Disconnecting switch unit
and lower circuit breakers.
MTU DSU
1848
1584
2112
2376
220A
1320 2640
3P 3P
Thermal magnetic
release
Thermal magnetic
1000~1600AF trip relay (OCR)
release
N type A type P type S type
Magnetic only
Electronic
release
OCR
Susol Smart MCCB Susol MCCB and Susol Smart MCCB device specifications
Susol Smart MCCB was developed by integrating digital technology based on ‧Breaking capacity and exterior size
Common
power device technology accumulated over 40 years. ‧Insulation voltage upgrade : 750V → 1000V
specifications
Relay and measurement functions for line protection have been upgraded, ‧Compatible with existing accessories
and by using accessory devices for connectivity between low - voltage devices,
data can be collected and analyzed to diagnose and maintain devices.
LS ELECTRIC takes the lead for a smart future with energy digitalization. Susol Smart MCCB ‧Fine relay function that can be finely adjusted : LSIG (Long time protection against overload, Short circuit protection,
Instantaneous protection, Earth fault protection)
features
‧Upgraded measurement accuracy : Current Class 1, Voltage ± 0.5%, Power and Power Class 2
‧Device diagnosis and maintenance
‧Dark gray exterior color with new PI
RS485 - ■ - ■ ■ ■
Communication
Mobile communication - - - - - ■
Renewable energy Infrastructure Residential/ Industrial EV charging
generation Commercial infrastructure • ETS/ ETSi : Standard • ETM/ ETMi : Multi - Function • ETHi : High - Performance • ETLi : Limited - Performance
46 47
Smart LV Solution
Model selecting guide Susol Smart MCCB
Basic format/
Ampere frame
Type Rated
current Number of poles
-
Plug-in
Standard
-
AX
Standard
Accessories
Smart MCCB
100 Ni Normal 3P 3-pole
P Plug-in Susol Smart MCCB is developed by combining digital technology with
160 Hi High 4-pole N-A-B-C
4P L LS ELECTRIC's power device technology accumulated over 40 years.
(N-R-S-T)
250
TS Li Limited 4-pole A-B-C-N The relay and measurement functions for line protection has been upgraded.
4P R
400 (R-S-T-N)
By using accessory devices for connectivity between low-voltage devices,
630
it is possible to diagnose and maintain devices by collecting and analyzing data.
800 Trip Unit (ETU)
ETSi Standard
ETMi Multi-Function
ETHi High-performance
ETLi Limited-performance
48 49