Brochures - RCWALL 081 - 462

The document summarizes an IT cooling system called RCWALL that is designed for data center cooling. Some key points: - RCWALL is a fan wall unit that provides versatile cooling for IT environments with high thermal loads. It has low installation costs and optimizes space usage. - The units do not require raised floors, have modular and stackable designs, and provide full accessibility to components from the front. - RCWALL is well-suited for hyperscale and colocation data centers due to its ability to optimize space and have low initial costs per kW of cooling capacity.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
267 views16 pages

Brochures - RCWALL 081 - 462

The document summarizes an IT cooling system called RCWALL that is designed for data center cooling. Some key points: - RCWALL is a fan wall unit that provides versatile cooling for IT environments with high thermal loads. It has low installation costs and optimizes space usage. - The units do not require raised floors, have modular and stackable designs, and provide full accessibility to components from the front. - RCWALL is well-suited for hyperscale and colocation data centers due to its ability to optimize space and have low initial costs per kW of cooling capacity.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 16

IT COOLING

ROOM COOLING

RCWALL FANWALL UNIT FOR


DATA CENTER COOLING.
FROM 77 TO 418 kW

melcohit.com
IT COOLING
ROOM COOLING

RCWALL
Extremely versatile solution for high thermal loads
in IT environments

RCWALL combines low initial investment costs, speed of installation


and optimization of the space occupied by the cooling system.

These aspects fit perfectly with modern Colocation and Hyperscale


data centers where the development time is rapid and special attention
is given to the costs of the entire plant.

Raised floor not needed Lower initial cost per kW

The absence of raised floor Reduced initial costs compared to


reduces costs and routine traditional solutions due to product
maintenance. design.

Modular design Connection flexibility

With stackable modules. Top and side hydraulic connections


are available to match the needs of
the plant.

Full frontal accessibility More room available for equipment

To main components from The positioning of the units in the


suction side (blown coil). technical corridor provides more
usable space for the server racks.

2/3
2/3
IT COOLING
ROOM COOLING

TECHNOLOGICAL
FEATURES
FAN WALL is completely versatile solution.
Each unit is stackable in order to increase
the kW per footprint.

FULL FRONTAL ACCESSIBILITY,


NT P ENDI N
COIL INCLUDED AT
E

G
P
Openable filters, removable fans,
and patented tilting movement of
the fan section, allow access to PA

G
TE N
any component inside the unit. N T P E N DI

TAILOR-MADE COIL
Thanks to the customization of the
heat exchanger, it is possible to satisfy
the request for particular delivery air
temperatures, specific delta T and
volumetric air flow rates.

MAGNETIC LAMP
The possibility to adjust the magnetic
lamp in any position facilitates inspection
and routine maintenance.

4/5
4/5

EC PLUG FANS

The use of permanent magnet motors


coupled with plug fans guaranteed
high efficiency.
The range boasts great scalability of
the volumetric air flow thanks to the
number of fans: from 2 up to 8.

GALVANIZED STEEL FRAME


Verification of structural strength
through drop tests from a height
of 30 cm.
Holes are provided in the brackets at
the base of the unit to facilitate lifting
and handling.

TOUCH DISPLAY (opt.)


The touch display makes it easy to
interact with the unit thanks to the
latest generation Human-machine
interface.

PRESSURE INDEPENDENT
CONTROL VALVE (opt.)
Pressure-independent electronic
control valve ensures accurate
modulation and energy savings.

HIGH EFFICIENCY FILTERS


Large filtering surface area ensures
low pressure drop and high efficiency.
IT COOLING
ROOM COOLING

HYPERSCALE AND
COLOCATION DATA CENTERS
Thanks to space optimization, installation
speed and a low investment cost per kW this air
conditioner is the ideal solution for Hyperscale and
Colocation data centers.

6/7
6/7

NO RAISED FLOOR
The absence of the raised floor ensures
lower initial costs of the system and reduces
routine maintenance.

CUSTOMIZATION
The organization of airflows and ducting depends
on the data center designer. This range provides
a wide choice of cooling powers, available air
flow rates and dimensions in order to satisfy any
requirement.

COOLING DENSITY
The increase the heating load forces the use of
increasingly powerful cooling units without taking up any
usable space. RCWALL is designed to increase the power
density per square meter by taking advantage of the
height, which are generally available in large data centers.
IT COOLING
ROOM COOLING

USER INTERFACE
& CONNECTIVITY
State-of-the-art interface in terms of user experience.

The 7” touch screen display (opt.) with easy-to-read color graphics ensures the immediate
visualization of the units’ status and provides simple alarms and event management.

Dedicated menus show the main operating parameters like


temperature, humidity, and ventilation.

MULTILANGUAGE
13 available languages

INTUITIVE ICONS
for a better user experience

REAL-TIME DISPLAY
of main operating variables

QUICK MENU ACCESS

8/9
8/9

KIPLINK CONNECTIVITY
Based on proprietary technology, KIPlink is an option that allows one to operate the unit directly
from a mobile device smartphone, tablet, or notebook

WI-FI KEYBOARD
Close to the unit with MEHITS APP access

MOBILE DEVICE

012345678910 iFXQ2

Master Unit

012345678910 iFXQ2

Master Unit

Direct access is achieved by scanning the QR-code


positioned on the front side of the unit.
012345678910 iFXQ2

Master Unit

LOCAL WI-FI

REMOTE CONTROL
In local network (LAN) of building with internet browser

BROWSER

LAN PORT

With a simple Ethernet connection, it is possible to connect KIPlink to the


facility LAN and get full access to the unit’s control with a browser.
Through a VPN it is also possible to access the menu from anywhere that
has an Internet connection.
IT COOLING
ROOM COOLING

GROUP CONTROL SYSTEMS

Thanks to LAN logics, always integrated in RCWALL, it is


possible to manage up to 15 modules in a single group
optimizing load distribution, alarm management and
LAN FUNCTION
back-up/stand-by of the units.

System solutions are also available to optimize the entire IT cooling system:
Fanwalls and Chillers.

HPC
Hydronic Plant Connect

1 ARCHITECTURE
Exploits proprietary LAN technology to Completely custom designed to be
connect Chillers’ and Fanwalls’ groups. connected to every Chiller and Fanwall.

2 PHYSICAL DEVICE
Completely Integrated in the units. Devoted cabinet with 19’’ touch display.

Optimization of the entire cooling


3 FUNCTION Full control and monitoring, advanced
system: Fanwalls, Chillers, and real time optimization based on
FC availability, fans, pumps, valves. unit performance curve.

Straightforward solution for Medium


4 APPLICATION State of the art solution for Large and
data centers with simple cooling Hyperscale data centers also with
plant scheme. complex cooling plant scheme.
Ideal for TIER III – TIER IV data centers.

10 / 11
10 / 11

AVAILABLE EQUIPMENT

PRESSURE INDEPENDENT
CONTROL VALVE

 Automatic and permanent hydronic balancing.


 Ensures the correct amount of water with
differential pressure changes and with partial loads.
 Real-time information on the measured flow rate
and cooling power.

LATERAL CONNECTION KIT

 In order to make Fanwall more flexible for the specific configuration of the hydronic
system, there are two types of connections for the water inlet and outlet from the unit:
top connections (standard) or lateral side connections (optional).

DAMPERS AND PLENUM

 The high level of customization allows different


couplings between dampers and plenum.
 Available dampers and plenum from catalog
or custom made.
IT COOLING
ROOM COOLING

RCWALL

RCWALL 081 091 131 151 201 231


Total cooling capacity kW 77,7 89,2 131 142 198 209
Air flow m3/h 21150 24800 34400 36300 47400 48800
Lenght (L) mm 1800 1800 2700 2700 3600 3600
Depth (D) mm 1600 1600 1600 1600 1600 1600
Height (H) mm 1750 2000 1750 2000 1750 2000
H

D L

12 / 13
12 / 13

RCWALL 162 182 262 302 402 462


Total cooling capacity kW 155 178 262 283 397 418
Air flow m³/h 42300 49600 68800 72600 94800 97600
Lenght (L) mm 1800 1800 2700 2700 3600 3600
Depth (D) mm 1600 1600 1600 1600 1600 1600
Height (H) mm 3500 4000 3500 4000 3500 4000
Return air conditions 37°C, 25% RH with IN/OUT water temperature 20/30°C
IT COOLING
ROOM COOLING

“ BY FAR THE BEST PROOF


IS EXPERIENCE” Sir Francis Bacon
British philosopher (1561-1626)

All over the world, in most data centers and in all projects where efficiency, quality, and
reliability are priorities, the precision RC IT Cooling air conditioners are the best guarantee.

TRUE MTG DATA CENTER


BANGKOK - THAILAND
Data center
Total cooling capacity: 3103 kW
Installed units:
50 x close control units

BRUNEI SHELL PETROLEUM


DATA CENTER
PANAGA-BRUNEI
Data center
Total cooling capacity: 1137 kW
Installed units:
4x Chilled water close control
air conditioners, downflow version

TECNOPOLO BOLOGNA
BOLOGNA-ITALY
Mixed-Use Development, Offices, Residential buildings,
Data Center
Cooling capacity: 6490 kW
Heating capacity: 6490 kW
Installed units:
2x NECS-WQ 0904, 2x NX-WN 0252, 1x WIZARD 1720,
2x WIZARD 2080, 3x ClimaPRO, 9x i-FR-G05-Z/E/S
3602, 28x w-NEXT2 K E8 U 180

14 / 15
14 / 15

Data Center in UAE


DUBAI - UNITED ARAB EMIRATES
Data center
Total cooling capacity: 25031 kW
Installed units:
5x ClimaPRO, 2x w-AV2 S U/S 065 E4, 6x w-AV2 S U/S
088 E5, 96x w-AV2 S U/S 210 E9, 16x i-FX-G01-Z/K
6042, 3x i-FX-G01-Z/A 3152

JUNIPER DATA CENTER


BANGALORE - INDIA
Data center
Installed units:
5x FOCS2-CA 4802, 2x i-FX(1+l)CA 4513

CED MONCALIERI DATA CENTER


MONCALIERI - ITALY
Data center
Total cooling capacity: 2868 kW
Installed units:
3x FX CA 4202

TRUE MTG DATA CENTER


BANGKOK - THAILAND
Data center
Total cooling capacity: 771 kW
Installed units:
3x i-NX-Z/SL 0302P, 1x i-FX-G04-Z/SL-A 2602,
8x CRRC, 2x Aisle Containment