0% found this document useful (0 votes)
269 views

GPT Au480

This document provides information about test parameters and reagents for an ALT/GPT assay. It includes details such as reagent information, sample volume and dilution factors, wavelength settings, measurement points, calibration type and parameters, expected value ranges, and stability information. The test measures alanine aminotransferase activity using a rate method with primary wavelength of 340nm and secondary wavelength of 660nm. Calibration is an A-B type formula with 1 calibration point using a calibrator with a concentration of 0. Stability is listed as 90 days for reagents and 30 days for calibration.

Uploaded by

xuanhungyte
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
269 views

GPT Au480

This document provides information about test parameters and reagents for an ALT/GPT assay. It includes details such as reagent information, sample volume and dilution factors, wavelength settings, measurement points, calibration type and parameters, expected value ranges, and stability information. The test measures alanine aminotransferase activity using a rate method with primary wavelength of 340nm and secondary wavelength of 660nm. Calibration is an A-B type formula with 1 calibration point using a calibrator with a concentration of 0. Stability is listed as 90 days for reagents and 30 days for calibration.

Uploaded by

xuanhungyte
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

ALT/GPT, AU480

System Reagent: R1: 6 x 44ml, R2: 3 x 22 ml Reagent ID: ###


Specific Test Parameters
General LIH ISE Range
Test Name: GPT ’  ! Type: Serum ’ Operation: Yes ’
Sample Volume 16 PL Dilution 0 PL OD Limit
Pre-Dilution Rate 1 Min. OD Max. OD
Reagents Volume: R1(R1-1) 16 PL Dilution  PL Reagent OD limit:
First Low -0 High 0.3
Last Low -0 High 0.3
R2 (R2-1) 40 PL Dilution 0 PL
Dynamic Range Low * High *
Correlation Factor A 1 B 0
Wavelength: Pri. 340 nm Sec. 660 nm Factor for Maker A 1 B 0
Method: RATE ’
Reaction slope: - ’ Onboard Stability 90 Days 0 Hour
Measuring Point 1: First 14 Last 25 LIH Influence Check # ’
Measuring Point 2: First Last Lipemia +++++ ’
Linearity: % Icterus ++ ’
No Lag Time: ’ Hemolysis ++++ ’

Specific Test Parameters


General ISE Range
Test Name: GPT ’  ! Type: Serum ’

Value/Flag: # ’ Level L: # Level H: #


Specific Ranges: Panic Value
From To
Sex Year Month Year Month Low High Low High
1. # ’ # # # # # # # #
2. # ’ # # # # # #
3. # ’ # # # # # #
4. # ’ # # # # # #
5.# ’ # # # # # #
6. # ’ # # # # # #
7. No demographics # #
8. Not within expected values # #
Unit U/L Decimal Places #

Calibration Specific
General ISE
Test Name: GPT ’  ! Type Serum ’ Use Serum Cal.
Calibration Type: AB ’ Formula: Y=AX+B ’ Counts: #
<Calibrator Parameters> Slope Check None ’
Calibrator † OD Conc Factor Range
Low High Allowable Range Check
Point 1: # ’ †* # # Reagent Blank

Point 2: ’ Calibration

Point 3: ’ Advanced Calibration

Point 4: ’ Operation Yes ’


Point 5: ’ Interval (RB/ACAL) Lot / Lot ’
Point 6: ’
Point 7: ’
Point 8: ’
Point 9: ’
Point10: ’
<Point Cal. For Master Curve> No. of Correction Points ’ Use Master Curve ’ Lot Calibration
Calibrator OD Conc OD Range Stability
Low High Reagent Blanks 30 Day 0 Hour
Point 1: Calibration 30 Day 0 Hour
Point 2:
MB Type Factor: 1-Point Calibration Point ’ With CONC-0

You might also like