0% found this document useful (0 votes)
102 views5 pages

Pi2794 02 - en GB

1. The document describes a flush pressure sensor with a 4-digit alphanumeric display and status LEDs. It has one analog and two digital outputs. 2. The sensor measures pressure from -1 to 10 bar with connections for viscous liquids or gases from -25 to 125°C. It has gold-plated contacts and is intended for food and beverage applications. 3. Electrical features include a 3.6-21mA operating current, PNP/NPN outputs, and short circuit, overload and reverse polarity protection. The analog output is scalable from 4-20mA and the switching frequency is up to 125Hz.

Uploaded by

Raymond Caniete
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
102 views5 pages

Pi2794 02 - en GB

1. The document describes a flush pressure sensor with a 4-digit alphanumeric display and status LEDs. It has one analog and two digital outputs. 2. The sensor measures pressure from -1 to 10 bar with connections for viscous liquids or gases from -25 to 125°C. It has gold-plated contacts and is intended for food and beverage applications. 3. Electrical features include a 3.6-21mA operating current, PNP/NPN outputs, and short circuit, overload and reverse polarity protection. The analog output is scalable from 4-20mA and the switching frequency is up to 125Hz.

Uploaded by

Raymond Caniete
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

PI2794

Flush pressure sensor with display


PI-010-REA01-MFRKG/US/ /P

Alternative articles: PI1704


When selecting an alternative article and accessories please note that technical data may differ!

1 alphanumeric display 4-digit


2 status LEDs
3 programming button

Product characteristics
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Measuring range -1...10 bar -14.5...145 psi -0.1...1 MPa
Process connection threaded connection G 1 external thread Aseptoflex Vario
Application
Special feature Gold-plated contacts
Application flush mountable for the food and beverage industry
Media viscous media and liquids with suspended particles; liquids and gases
Medium temperature [°C] -25...125; (145 max. 1h)
Min. bursting pressure 150 bar 2175 psi 15 MPa
Pressure rating 50 bar 725 psi 5 Mpa
Vacuum resistance [mbar] -1000
Type of pressure relative pressure; vacuum
No dead space yes
MAWP (for applications 50 bar 725 psi 5 MPa
according to CRN)

ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PI2794-02 — 13.04.2023 —
PI2794
Flush pressure sensor with display
PI-010-REA01-MFRKG/US/ /P

Electrical data
Min. insulation resistance [MΩ] 100; (500 V DC)
Protection class III
Reverse polarity protection yes
Integrated watchdog yes
2-wire
Operating voltage [V] 20...32 DC
Current consumption [mA] 3.6...21
Power-on delay time [s] 1
3-wire
Operating voltage [V] 18...32 DC
Current consumption [mA] < 45
Power-on delay time [s] 0.5
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Outputs
Total number of outputs 2
Output signal switching signal; analogue signal; IO-Link; (configurable)
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / normally closed; (parameterisable)
Number of analogue outputs 1
Analogue current output [mA] 4...20, invertible; (scalable)
Short-circuit protection yes
Type of short-circuit
pulsed
protection
Overload protection yes
2-wire
Max. load [Ω] 300
3-wire
Max. voltage drop switching [V]
2
output DC
Permanent current rating of [mA]
250
switching output DC
Switching frequency DC [Hz] 125
Max. load [Ω] (Ub - 10 V) / 20 mA
Measuring/setting range
Measuring range -1...10 bar -14.5...145 psi -0.1...1 MPa
Set point SP -0.98...10 bar -14.2...145 psi -0.098...1 MPa
Reset point rP -1...9.98 bar -14.5...144.7 psi -0.1...0.998 MPa
Analogue start point -1...7.5 bar -14.5...108.7 psi -0.1...0.75 MPa
Analogue end point 1.5...10 bar 21.8...145 psi 0.15...1 MPa
In steps of 0.01 bar 0.1 psi 0.001 MPa

ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PI2794-02 — 13.04.2023 —
PI2794
Flush pressure sensor with display
PI-010-REA01-MFRKG/US/ /P

Factory setting SP1 = 2.50 bar rP1 = 2.30 bar


SP2 = 7.50 bar rP2 = 7.30 bar
ASP = 0.00 bar AEP = 10.00 bar
Accuracy / deviations
Switch point accuracy
< ± 0,2; (Turn down 1:1)
[% of the span]
Repeatability [% of the span] < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation < ± 0,2; (Turn down 1:1 , linearity, incl. hysteresis and
[% of the span] repeatability , limit value setting to DIN EN IEC 62828-1)
Linearity deviation
< ± 0,15; (Turn down 1:1)
[% of the span]
Hysteresis deviation
< ± 0,15; (Turn down 1:1)
[% of the span]
Long-term stability
< ± 0,1; (Turn down 1:1; per year)
[% of the span]
Temperature coefficient zero
point < ± 0,05; (0...70 °C)
[% of the span / 10 K]
Temperature coefficient span
< ± 0,15; (0...70 °C)
[% of the span / 10 K]
Response times
Damping process value dAP [s] 0...30
Damping for the analogue [s]
0.01...99.99
output dAA
2-wire
Step response time analogue [ms]
45
output
3-wire
Min. response time of [ms]
3
switching output (dAP)
Step response time analogue [ms]
7
output
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.0
Profiles no profile
SIO mode yes
Required master port type A
Process data analogue 1
Process data binary 2
Min. process cycle time [ms] 2.3
Supported DeviceIDs Type of operation DeviceID
Default 157
Operating conditions
Ambient temperature [°C] -25...80
Storage temperature [°C] -40...100
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PI2794-02 — 13.04.2023 —
PI2794
Flush pressure sensor with display
PI-010-REA01-MFRKG/US/ /P

Protection IP 67; IP 68; IP 69K


Tests / approvals
EMC DIN EN 61000-6-2
DIN EN 61000-6-3
Shock resistance DIN EN 60068-2-27 50 g (11 ms)
Vibration resistance DIN EN 60068-2-6 20 g (10...2000 Hz)
MTTF [years] 160
Note on approval factory certificate available as download at www.factory-certificate.ifm
Mechanical data
Weight [g] 351.8
Materials stainless steel (1.4404 / 316L); FKM; PTFE; PBT; PEI; PFA
Materials (wetted parts) ceramics (99.9 % Al2O3); stainless steel (1.4435 /
316L); surface characteristics: Ra < 0,4 / Rz 4; PTFE
Min. pressure cycles 100 million
Process connection threaded connection G 1 external thread Aseptoflex Vario
Displays / operating elements
Display Display unit LED, green
switching status LED, yellow
function display alphanumeric display, 4-digit
measured values alphanumeric display, 4-digit
Display unit bar; psi; MPa; % of the span
Remarks
Pack quantity 1 pcs.
Electrical connection
Connector: 1 x M12; coding: A; Contacts: gold-plated

ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PI2794-02 — 13.04.2023 —
PI2794
Flush pressure sensor with display
PI-010-REA01-MFRKG/US/ /P

Connection

1 connection for 2-wire operation


2 connection for 3-wire operation :
OUT1 switching output
OUT2 switching output
analogue output
3 connection for IO-Link parameter setting (P = communication via IO-Link)

ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PI2794-02 — 13.04.2023 —